HomeMy WebLinkAbouta00442" 131 5/8"
42" 89 5/8"9 5/8"63 3/4"29 1/2" 9 5/8"63 3/4"1 1/2"3/4" 23 1/4"4"9 5/8" 20 1/4"73" 102 7/8"131 5/8"
E5
A-2
E5
A-2
11
01) 2" ADJUSTABLE SHELVES
02) LIFT DOOR W/ HYDRAULIC STABILIZATION
03) LIFT DOOR W/ HYDRAULIC STABILIZATION
04) 2" ADJUSTABLE SHELVES
05) 6-DRAWER BASE
06) 6-DRAWER BASE
07) TRIM BOARD TO CEILING TOPPED W/ COVE MOLDING
22 33
44
55
66
77
41 1/2" 41 1/2" 41 1/2" 41 1/2"5 1/8"35"3 1/2"1"69 3/4"1 1/2"3/4" 29 3/4"4" 1"28 3/4"41"36" 209 5/8"
CL
41 1/2" 126 5/8"
18" 39" 52" 39" 18"5 1/8"35"3 1/2"
E1
A-2
E1
A-2
11 22 33 44 55
66 77
88
99 1010
1111 1212 1313 1414
01) LIFT DOOR W/ HYDRAULIC STABILIZATION; NO TOP (GWB ANGLED CEILING BEHIND)
02) LIFT DOOR W/ HYDRAULIC STABILIZATION; NO TOP (GWB ANGLED CEILING BEHIND)
03) LIFT DOOR W/ HYDRAULIC STABILIZATION; NO TOP (GWB ANGLED CEILING BEHIND)
04) LIFT DOOR W/ HYDRAULIC STABILIZATION; NO TOP (GWB ANGLED CEILING BEHIND)
05) LIFT DOOR W/ HYDRAULIC STABILIZATION; NO TOP (GWB ANGLED CEILING BEHIND); RIGHT SIDE FINISHED
06) SINGLE DOOR W/ BUILT-IN IRONING STATION INSIDE (INTEGRATED AC & LIGHT)
07) DOUBLE DOORS W/ ADJ SHELVES
08) OPEN
09) DOUBLE DOORS W/ ADJ SHELVES
010) SINGLE DOOR W/ ADJ SHELVES; RIGHT SIDE FINISHED
011) 4-DRAWER BASE
012) 3-DRAWER BASE
013) 3-DRAWER BASE
014) 4-DRAWER BASE; RIGHT SIDE FINISHED
015) TOP MATCHES CABINETS
1515
RECESSED SHADOW LINE
28"
12" 18"
24"
S1
A-2
PAINTED GWB BEHIND LIFT DOORSTRIM BOARD W/ COVE MOLDING
DEMOLITION PLAN
A-4
Adam Gibson and Adam Gibson
Design, LLC does not represent or
imply itself to be or employ licensed
architects or engineers. Adam
Gibson and Adam Gibson Design, LLC
assume no responsibility for structural
or dimensional errors or omissions.
Owner is responsible to verify and
check all notes, details, elevations,
sections and floor plans for any errors
or omissions prior to start of
construction. No warranties are
expressed or implied including
compliance of this plan with
applicable building codes. Owner is
responsible to assure that the building
meets or exceeds local codes and
regulations. It is the responsibility of
Owner to obtain any and all structural
analysis, engineering and
specifications that may be required in
the municipality in which it is to be
built. The selection and application of
correct structural materials is the
responsibility of Owner. It is suggested
that owner hire a general contractor
to monitor and comply with the
responsibilities listed within this
paragraph. In no event shall Adam
Gibson or Adam Gibson Design, LLC
be responsible for project budgeting
or bidding of third parties based on
Designers plans. In the event that any
liability is imposed on Adam Gibson or
Adam Gibson Design, LLC, Adam
Gibsons or Adam Gibson Design,
LLCs liability to Owner or any third
party shall not exceed the price paid
for the construction drawings.
½" = 1'
U.N.O.
SHEET:
SCALE:DESIGNED FOR:M ARY JO AND STEVE W EDDING
5033 ST CHARLES PLACE
CARM EL, IN 46033ADAM G IBSO N DESIG N, LLC200 S. RANG ELIN E RD. SUITE 223CARM EL, IN 46032317.255.5001ADAM @ADAM G IBSO N.CO MDESIGNED BY:Wedding Master 13-X10
DATE:
11/10/2017
09/21/18
Mike Sheeks