REFLECTED CEILING PLAN-^
SCALE: 1/8, = 1'-0" --_
NORTH
ELECTRICAL PLAN
SCALE: 1/8" = 1'-0"
CORRIDOR
506
NORTH
CORRIDOR
508
REFLECTED CEILING PLAN NOTES
1. MECHANICAL AND ELECTRICAL IS DESIGN—BUILD. DESIGN—BUILD CONTRACTOR
TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND
NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS,
EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN—BUILD CONTRACTOR TO
COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE
BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER
TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR
TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS
FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING.
2. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL
SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT
OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, �TC.) AND VERIFY
CONFORMANCE -WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR
IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND
OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR
SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW.AND COORDINATION
OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC
REVIEW ONLY.
3. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON ;WALL AT DOORWAY TO
ROOM, TYPICAL UNLESS NOTED OTHERWISE.
4. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY
DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH
CONSTRUCTION.
5. CEILING HEIGHT IS 9'-0" A.F.F. UNLESS OTHERWISE NOTED.
6. IN LOCATIONS OF (2) TWO OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES
ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION.
ELECTRICAL NOTES
1. E.C. TO COORDINATE ELECTRICAL REQUIREMENTS FOR SPECIAL EQUIPMENT
WITH TENANT.
2. E.C. TO PROVIDE JUNCTION BOXES AT TELEPHONE AND
COMPUTER LOCATIONS AS INDICATED ON PLANS. COMPLETE
TELEPHONE AND COMPUTER SYSTEMS (MATERIAL & LABOR),
ARE PROVIDED BY TENANT UNLESS OTHERWISE INDICATED.
3. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT.
4. E.C. TO INSURE DEDICATED OUTLET TYPES TO BE COMPATIBLE
WITH EQUIPMENT
5. WALL MOUNTED OUTLETS TO BE MOUNTED 0 18" A.F.F. UNLESS
OTHERWISE NOTED.
ELECTRICAL PLAN NOTES.
EPt PROVIDE POWER FOR COPIER. E.C. TO VERIFY POWER REQUIREMENTS.
EP2 PROVIDE SEPERATE PRICING FOR ELECTRICAL OUTLETS IN CORRIDOR AND STORAGE
ELECTRICAL LEGEND-,
SYMBOL DESCRIPTION
6 NEW DUPLEX WALL OUTLET
6D NEW DEDICATED CIRCUIT OUTLET
,I.I,GFI NEW GROUND FAULT INTERUPT CIRCUIT OUTLET
v NEW PHONE/DATA WALL OUTLET (BOX AND PULL STRING)
+44 INCHES ABOVE FINISHED FLOOR TO MIDDLE OF FACE PLATE
CEILING LEGEND
NEW 2' X 4' FLOURESCENT FIXTURE, BUILDING
STANDARD SPECIFICATION.
NEW 1' X 4' FLOURESCENT FIXTURE, BUILDING
STANDARD SPECIFICATION.
t NEW CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION
DUAL -LITE, BUILDING STANDARD SPECIFICATION
NEW 2 X 2 LAY -IN GRID SUSPENSION SYSTEM
NEW 4" CEILING BULKHEAD AT 8'-8"AFF
TWO WAY SWITCH
NL NIGHTLIGHT LOCATION
CEILING PLAN NOTES
CP1 PROVIDE SEPERATE PRICING FOR CORRIDOR GRID, LIGHT FIXTURES
BAND NEW BULKHEADS
cP2 PROVIDE ALTERNATE PRICING FOR DUAL BALLAST 2X4
LIGHTING IN OFFICE 504
•.
Duke
REALTY CORPORATION
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone: 317 808-6000
Fax: 317 808-6797
CP
ct
Irrt�erior9
Landscape ArcWdedure
Land &wwaft
Six Parkwood Office
600 East 96th Street, Suite 550
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 ®Copyright 2001
c
0
a�
O
o
cq
m
�; a0
:N
a
(n r
D
C
U
Z
a
J
CL
J
Q
U
Q
z
U
W
�o�
W
W
LL
NOZ
U) -:�: w
J
Y Ln
06
W::j
p
{�
W
CL
�XQ
Z
CO)V) Q
ES
W
z
U
0
W
V
W
J
LL
W
Certified By:
Drawing Number:
5A202
Of Sheets
Duke Job Number:
A/E Job Number:
21423S
ARCHITECT:
CSO
.600 E. 96TH STREET, SUITE 550
INDIANAPOLIS, INDIANA 46240
(317) 848.7800 (317) 574.1869 FAX
CONTRACTOR:
Duke
REALTY CORPORATION
600 E. 96th STREET
SUITE 100
INDIANAPOLIS, IN 46240
PHONE: (317)808-6000
INDEX OF DRAWINGS
• COVER
MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH
• 5A201
CONSTRUCTION PIAN
• 5A202
REFLECTED CEILING &ELECTRICAL PIAN
• 5A601
ELEVATIONS & DETAILS PIAN
• Sff-_5_1
HVAC PIAN
APPROVED AS SUBMITTED APPROVED AS NOTED REJECTED
SIGNATURE DATE
COMPANY
KEYPLAN
SCALE: NTS
M E T SIX PARKWOOD SUITE 525
SPECIFICATIONS AND GENERAL NOTES
0 CONTRACT CONDITIONS
0.1 THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION,
ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR
CONSTRUCTION'. THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF
THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE
RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED
AS FOLLOWS:
3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND
FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE
PROCEEDING WITH CONSTRUCTION.
3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE
RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES.
3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY
GOVERNMENTAL FEES, LICENSES AND INSPECTIONS.
3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING
ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND
WORKMANSHIP.
10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY
PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE
CONTRACTOR'S RESPONSIBILITY.
0.2 WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES,
RULES AND REGULATIONS.
0.3 ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD
QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF
THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION
IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED
PROJECT.
0.4 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE
SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND
WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE
SPECIFIED CAPACITIES OF THE EQUIPMENT.
0.5 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS
ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING
JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL
GOVERN THE WORK.
0.6 NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE
SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN
DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT
CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY
OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S
INTERPRETATION.
0.7 INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
1 GENERAL REQUIREMENTS
1.1 WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS
WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR
BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT.
1.2 THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS
INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE
AND "FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL
COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING,
AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE
WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR
REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS.
1.3 CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING
ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND
WORKMANSHIP.
1.4 SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE
FOLLOWING ITEMS:
.1 METAL FABRICATIONS.
.2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS.
.3 DOORS, FRAMES AND HARDWARE.
.4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL
PANEL ).
.5 VCT FLOORING AND BASE ( COLOR SAMPLES ).
.6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ).
.7 PAINT ( 6' X 6' ON ACTUAL SURFACE ).
.8 WALLCOVERINGS ( 9' X 9' DYE LOT CUTTING ).
.9 SIGNAGE ( SAMPLE SIGN ).
.10 LIGHT FIXTURES ( CATALOG CUTS ).
1.5 TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES,
TEMPORARY ENCLOSURES, FIRE PROTECTION, HEAT AND POWER
WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR
THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING
CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S
AGENT.
1.6 THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND
OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR
SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS,
TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT
EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE.
THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES
ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT
ADDITIONAL CHARGE TO THE PARTY AFFECTED.
1.7 THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS
CONTRACT EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES AND ALARMS
TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS.
1.8 SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT
PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED,
SUBMIT THE FOLLOWING INFORMATION:
.1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF
PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES.
.2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED.
.3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL
CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO
ACCOMMODATE THE SUBSTITUTION.
.4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL
AFFECT THE CONTRACT SUM AND CONTRACT TIME.
1.9 STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME
FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING.
1.10 THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR
HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE
BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN
REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS.
1.11 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL
CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION
EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE
PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
1.12 PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION
NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND
MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN
THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE
INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL
PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD.
2 DEMOLITION
2.1 COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE
EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE
BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW
WORK.
2.2 WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR
EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT,
OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION
TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND
SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING
ADJACENT SURFACES, INCLUDING WITH REGARD TO MAIERIALS AND
WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED
TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR
ADDITIONAL WORK RELATED TO SUCH ACTIVITIES.
2.3 WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED
MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL
BE INCLUDED.
2.4 REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE
DRAWINGS.
2.5 ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE
ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED
FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS ANS
METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW
FINISHES.
2.6 EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL
REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR
NOTED TO BE REPAIRED.
2.7 SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS.
2.8 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS
REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK
IN SCOPE OF CONTRACT.
2.9 PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING
DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS
ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS
SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DRT
THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS.
2.10 CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICE"
AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY
SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE -
OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED
CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO
DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS
PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS.
CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A
RECORD SEPIA TO SERVE AS PART OF THE 'AS -BUILT° SET.
2.11 PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT,
SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE
DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN.
5 METAL FABRICATIONS
5.1 PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED
OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS
REQUIRED TO COMPLETE WORK.
6 WOOD AND PLASTIC
6.1 CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION
GRADE" LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE
CONTENT.
6.2 PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE
EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA
C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32'.
6.3 FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND
PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA
C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH
CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING
JURISDICTION.
6.4 FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE' AWI
STANDARDS.
.1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR
TO FABRICATION OF MULTIPLE UNITS.
6.5 COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH
NEMA LD 3 AND GP -50 (0.050' NOMINAL THICKNESS).
.1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL
SURFACES.
.2 PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE
ELECTRICAL OR DATA OUTLET LOCATIONS.
6.6 CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 4006 FCR
PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS.
.1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS:
GP -50 (0.050' NOMINAL THICKNESS); VERTICAL SURFACES: CP -28
(0.028" NOMINAL THICKNESS); EDGES: GP -28 (0.028" NOMINAL
THICKNESS).
.2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28.
.3 CABINET HARDWARE SCHEDULE:
.1 HINGES: FULLY CONCEALED, SELF-CLOSING '1000 SERIES'
BY GRASS OR EQUAL.
.2 PULLS: WIRE PROJECTING TYPE, DRILLING 4" ON CENTER,
#4483 OR EQUAL AS MANUFACTURED BY STANLEY.
.3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH
MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS
MANUFACTURED BY STANLEY.
.4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES
WITH POSITIVE STOP AND LOCKOUT POSITION, WITH
HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS
MANUFACTURED BY KNAPE & VOGT.
.5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF
SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION
MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED
SHELVING STANDARDS AS PRODUCED BY KNAPE do VOGT
OR EQUAL.
6.7
MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH
9.10
PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS.
6.8
DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING,
WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED
WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY
OPERATING FOR TEN DAYS.
6.9
INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND
STRAIGHT WITH NO DISTORTIONS. i
6.10
JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM
WIDTH NOT TO EXCEED 1/8 U.O.N.
6.11
GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL
OUTLETS.
7
JOINT SEALERS '
Ti
ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS
AND FIXTURES:
.1 "DOW CORNING 786'; DOW CORNING CORP.
.2 "SCS 1702 SANITARY"; GENERAL ELECTRIC CO.
.3 "863 #345 WHITE'; PECORA CORP.
.4 'PROGLAZE WHITE"; TREMCO CORP.
.5 "OMNIPLUS"; SONNEBORN BUILDING (PRODUCTS ;
7.2
ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING
SURFACES:
.1 "CHEM -CALK 600"; BOSTIK CONSTRUCTION PRODUCTS DIV.
.2 AC -20"; PECORA CORP.
.3 "SONOLAC'; SONNEBORN BUILDING PRODUCTS
.4 'TREMCO ACRYLIC LATEX 834'; TRENCO, INC.
8
DOORS AND WINDOWS
8.1
INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS
NOTED OTHERWISE. COLOR TO BE SELECTED 13Y DESIGNER.
8.2
INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED
OTHERWISE, DOORS TO BE BUILDING STANDARD FINISH.
8.3
DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH
AND LOCKSETS.
8.4
GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048
REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. ;
9
FINISHES
9.1
GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645.
.1 INSTALL "ELIMINATOR' TYPE HEAD TRACK AT WALLS TERMINATING
AT CEILING. USE PREFORMED OUTSIDE CORNERS.
9.2
GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE 'X' TAPERED
EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND
JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE
WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS.
.1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED
INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH •
MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA -
216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND
9,11
FINISHING OF GYPSUM BOARD.
9.4
CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM
DAMAGED OR SOILED TILES.
COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS
IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL
REFLECTED CEILING PLAN SHALL GOVERN.
10
.2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN
LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS
10.1
UNLESS NOTED OTHERWISE.
9.5
INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR
CASED OPENING UNLESS NOTED OTHERWISE.
1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET
MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH
CARPET.
9.6
RESILIENT FLOORING:
.1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS
ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT
OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO
AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER.
.2 BASE: AT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID
BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING
ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS.
9.7
USE AN APPROVED CEMENTMOUS FILLER TO PATCH CRACKS, SMALL
HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM
SURFACE VARIATION OF V IN 10 FEET, NON -CUMULATIVE.
9.8
CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING
STANDARDS:
FLAMMABILITY: ASTM 2859
SURFACE BURNING: ASTM E84
SMOKE DENSITY: ASTM E662
SOUND ABSORPTION: ASTM C423
FADE RESISTANCE: AATCC 16E
STATIC RESISTANCE: AATCC 134
WARRANTY: 10 YEARS
.1 INSTALL BROADLOOM CARPET BY DIRECT GLUE.
NDIANAPOLIS, INDIANA
PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR
PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY,
REINSTALL SUCH ITEMS.
.1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT
SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD
FOR THE VARIOUS SUBSTRATES, AS INDICATED.
1. FERROUS METAL:
A. ACRYLIC SEMI -GLOSS ENAMEL FINISH:
1. PRIMER: i COAT 141702 METALCLAD ACRYLIC
LATEX PRIMER.
2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC
SEMI -GLOSS ENAMEL.
2. NON-FERROUS METAL:
A. ACRYLIC SEMI -GLOSS ENAMEL FINISH:
1. PRIMER: i COAT #41702 METALCLAD ACRYLIC
LATEX PRIMER.
2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC
SEMI -GLOSS FINISH
3. FERROUS STRUCTURE:
A. ACRYLIC DRY FOG FIAT FINISH:
1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER
REDUCIBLE ACRYLIC DRY FOG COATING
4. NON-FERROUS STRUCTURE:
A ACRYLIC DRY FOG FLAT FINISH:
1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER
REDUCIBLE ACRYLIC DRY FOG COATING.
8. WOOD:
A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH:
1. PRIMER: 1 COAT 151701 WONDER -PRIME LATEX
PRIMER -SEALER.
2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC
SEMI -GLOSS ENAMEL.
B. STAIN -VARNISH RUBBED FINISH:
1. FILLER: 1 COAT 14800 WONDER WOODSTAIN
PASTE WOOD FILLER (OPEN GRAIN WOODS).
2. STAIN: 1 COAT 196XX WONDER WOODSTAIN
ALKYD STAIN.
3. SEALER: 1 COAT #4900 WONDER WOODSEALER
QUICK DRY SEALER.
4. FINISH: 2 COATS #4600 WONDER WOODSTAIN
ALKYD SATIN VARNISH.
10. GYPSUM WALLBOARD:
A. ACRYLIC LATEX SATIN ENAMEL FINISH:
1. PRIMER: 1 COAT #50801 WONDER TONES LATEX
PRIMER -SEALER.
2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC
LATEX SATIN ENAMEL.
13. PRECAST CONCRETE:
A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS)
1. PRIMER: i COAT #1502 WONDER -SHIELD ACRYLIC
LATEX HOUSE PAINT PRIMER.
2. FINISH: 1 COAT #44101 DSV -VO- (EX LATEXTEXTURE COATING.
WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLEAN AND
WITHOUT WRINKLES, GAPS OR OVERLAPS.
.1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS fti;E NOT
ACCEPTABLE.
.2 SEAMS MUST BE AT LEAST 2" FROM INSIDE CORNERS AND 6' FROM
OUTSIDE CORNERS.
SPECIALTIES
ARE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO
BUILDING STANDARD, PROVIDE A INDUSTRIES AMBASSADOR" SERIES,
SEMI RECESSED, DUO -PANEL, FIELD PAINTED.
iW N
ti �6 v
RB eiyrvd ,Type c 1_4/
�7?) CAI ,
st, Perm-
F(eviewed >3Y'
-T11��
A
12 FURNISHINGS
12.1 CASEWORK:
.1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE
FOLLOWING:
.1 IMPERIAL CABINET CO., INC.
.2 MERILLAT INDUSTRIES, INC.
.3 YORKTOWNE CABINETS
15/16 MECHANICAL AND ELECTRICAL
15/16.1 MECHANICAL (INCLUDING PLUMBING, ARE PROTECTION AND HVAC) AND
ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE.
RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS
ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC
CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL
BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE,
INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND
ELECTRICAL SYSTEMS.
15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF
DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND
PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A -
CERTIFIED ENGINEER.
15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S
DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS'
DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN)
AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL
DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND
OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK.
15/16.4 SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE
OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT
SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL
COORDINATE WITH OTHER CEILING COMPONENTS.
15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS
SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR
OWNER'S AGENT.
15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED.
WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED.
VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED
EQUIPMENT.
15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE
GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER.
15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND
INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL
COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND
TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE
INSTALLATION SHALL OCCUR.
15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF
OUTLETS, UNLESS OTHERWISE NOTED.
15/16.10 ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD
COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE
IVORY.
15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY
SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL
PROVIDING PROPER ACCESS TO RECEPTACLES.
15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL
FOR SPECIFIC LOCATION.
15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET
LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO '
OBSERVE PRIOR TO ANY COMMENCEMENT OF 'ROUGH -IN' r 1
CONSTRUCTION. 0
GN GENERAL NOTES
GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND
REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO
PROCEEDING WITH CONSTRUCTION.
GN2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED:
A. TO FINISHED FACE OF GYPSUM BOARD.
B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS.
C. TO TOP OF FINISHED FLOORS.
D. TO BOTTOM OF FINISHED CEILINGS. La
GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION,
EXISTING CONSTRUCTION AND WALL TYPES.
GNA TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED
OTHERWISE.
GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION
LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS
SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT,
NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING
WITH CONSTRUCTION.
GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT L3
FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT.
DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS
OBSERVATION.
GN.7 FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT
LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT
FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4' IN 20'-0' NON-
CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. Gd
GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO �► �``r �c���0�.
CLOSE -IN OF WALLS. y
GN.9 SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT
PERIMETER WITH ACOUSTICAL OR FIRE RATED SEALANT AS APPLICABLE �Q�
PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBST V,`G�'�
PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTE •p1 O� O
TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRO
JUNTION BOXES ARE NOT PERMITTED.
GNAO ALL CAPPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIEDY
a
CONTRACTOR.
CITY OF CARMEL/CLAY TOWNSHIP
Dept. of Community Services -- Building & Code Enforcement
One Civic Square 1st Floor; Carmel, TN 46032
' LAN AUTHENTICATION CERT 14CATIONS AND AGREEMEN ,
Ai the authorized agent responsible for obtaining a permit or permits, I certify that these plans
are IDENTICAL to those released for construction by the Indiana Dept. of Fire & Building
Services. I also understand that if it is determined that these plans are not identical, a STOP
WORK ORDER will be served, as required under the,,Ordinances referenced below.
6. r l�
Authorized Signature
Required under Chapter 7, Section 10 of the Carmel City Code, entitled"
Building Code" and Section 29.4.2
and Section 29.4.3 entitled "Administration". Required by Carmel / Clay Township Zoning Ordinance, Section
31.1 entitled "Violations and Penalties".
ILS:Permits /Forms /AuthentSticker11-01 Date _.
2-13-02
CSO #21423
T
CONSTRUCTION PLAN
SCALE: 1/8" = 1'-0"
NORTH
D 0 0 R S C H E D U L E
cso
AfChiiec�ire
DOOR
FRAME
HARDWARE
REMARKS
' SIZE
FAX 317.574.0957 ®Copyright 2001
_
3' BIRCH PRE-
t.�.1
_
N
LZ
C) Y9
MOHAWK DOOR
I v
e so
w
Q
m�
J
Z
�N
a
LEVER
�-
W o
Wm
HARDWARE
Z w
Z
Z
Q
O
__j
Q
O
tYJC>
Wco
o
I
Z
U
Fw—
w
Iw—
w
II II II
O Z
(�
W
Uj
_
_17
L
w
H
w
1111
_jcna C-) C1
500
RECEPTION
3'-0"
FULL HT
1 3/4"
WD/GL
D2 .
WD
D2
L,S,CL,DB
CO)
501
CONFERENCE
3'-0"
FULL HT
1 3/4"
WOOD
D1
HM
D1
PS,S
502
OFFICE
3'-0"
FULL HT
1 3/4
WOOD
D1
HM
D1
PS,S
2
503
OFFICE
3'-0"
FULL HT
1 3/4"
WOOD
D1
HM
D1
PS,S
Duke Job Number:
504
OFFICE
3'-0"
FULL HT
1 3/4
WOOD
D1
HM
D1
PS,S
505
WORK RM
3'-0"
FULL HT
1 3/4"
WOOD
I D1
HM
D1
L,S
507
STORAGE
3'-0"
FULL HT
1 3/4"
WOOD
D1
HM
D1
L,S
RELOCATED FROM EXIST
508
VACANCY
3'-0"
FULL HT
1 3/4
WOOD
D1
HM
D1
L,S
CONSTRUCTION NOTE
1 . DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE
OF. FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE.
2. SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION
AND WALL TYPES.
3. SAVE ALL REMOVED ITEMS FOR OWNER, PER OWNER'S
DIRECTION, UNLESS OTHERWISE SPECIFIED
4. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF
NEW FLOOR FINISHES AS SCHEDULED.
5. ALL NEW DOORS TO BE HINGED 6" AWAY FROM WALL.
6. PROVIDE CONCEALED WALL BLOCKING AS REQUIRED WHERE NEW
SHELVING, PLUMBING AND CASEWORK ARE NOTED.
( f` 7. ALU WALLS SHALL BE CHAULKED OFF FOR DESIGNER'S REVIEW
TO NEW WALL CONSTRUCTION
8. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND
18". CLEAR ON PULL SIDE OF DOOR UNLESS NOTED OTHERWISE
TO MEET ADA CODE REGULATIONS.
9. ALL' NEW TRACK AND TRIM AT WALL/CEILING CONDITIONS SHALL MATCH
EXISTING COLOR AND MATERIAL TO PROVIDE CONTINUOUS/CONSISTENT
APOEARANCE THROUGHOUT CEILING.
10. BUILDING OWNER AND/OR G.C. TO PROVIDE MINISBUNDS AT ALL PERIMETER
WINDOWS. EXISTING MINIBLINDS TO BE RELOCATED ARE TO BE STORED
DURING CONSTRUCTION PHASE, THEN CLEANED AND REINSTALL UPON
COMPLETION OF CONSTRUCTION.
11. ALL• NEW AND EXISTING FIRE EXTINGUISHER CABINETS TO BE VERIFIED
BY LIFESAFETY CONTRACTOR. CONTRACTOR TO VERIFY NEED FOR
ANY' ADDITIONAL FIRE EXTINGUISHER CABINET LOCATIONS. IF
ADDITIONAL FIRE EXTINGUISHER CABINETS ARE REQUIRED, LOCATIONS OF
MUST BE SUBMITTED TO CSO INTERIORS FOR LOCATION REVIEW FOR
AESTHETICS PURPOSES ONLY.
l A
DOOR ELEVATIONS
SCALE: 1/4" = 1'-0"
TYPICAL WALL TYPE—,
TYPICAL AT ALL EXTERIOR
WALLS- 5/8" TYPE X G.W.B.
FINISH BELOW EXISTING
WINDOW SILL COVER
METAL STUD
coat Ro
1� SECTION-
5A201 SCALE: 1/2"=1'-0"
n
J
3" WOOD FRAME
STAINED (WS1)
3' BIRCH STAINED (WS1
DOOR WITH 1/4" TEMP RED
GLASS INSET
LEVER
HARDWARE
D2
PREFINISHED ALUMINUM RECEIVER
TRIM "GB350" - FASTEN AT WINDOW
SILL & SET IN A CONTINUOUS BEAD OF
ACOUSTICAL SEALANT. TRIM COLOR
TO MATCH BLDG. WINDOW MULLIONS.
LINE OF EXISTING WINDOW SILL COVER
BELOW
CONTINUOUS
BEAD OF
ACOUSTICAL SEALANT
D AND SHELF
SII
WALL LEGEND
NOTE: ALL WALLS TO BE WALL TYPE (W1) UNLESS NOTED OTHERWISE
EXISTING CONSTRUCTION TO BE REMOVED
EXISTING PARTITION TO REMAIN
WX= NEW WALL CONSTRUCTION TO BE:
3
2-1/2- METAL STUDS @ 24" O.C. WITH 5/8"
GYPSUM BOARD EACH SIDE. WALLS TO
EXTEND TO UNDERSIDE OF CEILING LINE.
WX= NEW DEMISING WALL CONSTRUCTION TO BE:
2-1/2" METAL STUDS @ 24" O.C. WITH 5/8"
—71—
GYPSUM BOARD EACH SIDE. WALLS TO .
EXTEND TO UNDERSIDE OF CEILING LINE.
PROVIDE 2 1/2" SOUND INSULATION IN '
WALL AND ON HORIZONTAL SURFACE ABOVE
THE CEILING. INSULATION TO EXTEND
2'-0" IN BOTH DIRECTIONS FROM CENTER-
LINE OF WALL.
WX= NEW WALL CONSTRUCTION TO MATCH ADJACENT
CORRIDOR PARTITION CONSTRUCTION.
•
® DENOTES AREA NOT IN CONTRACT
DENOTES NEW MILLWORK
0 NEW DOOR AND FRAME.
REFER TO DOOR SCHEDULE.
CONSTRUCTION PLAN NOTES
FP1 ALIGN FINISHED FACES.
FP2 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS
USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION
FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT
BEFORE. PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 1/5A201.
FP3 NEW RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED i
IN WALL AT THIS LOCATION. PAINT TO MATCH ADJACENT WALL SURFACE.
6 COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE
FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MANUF. MANUAL.
UNDERCOUNTER REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE
FP5 POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQ. WITH MANUF. MANUAL.
PROVIDE 3/4" x 3'W x 5'L FIRE RETARDANT PLYWOOD PHONE BOARD. PHONE BD.
FPs PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT
WALL FINISH.
FP7 DEMO EXISTING WALL AND DOORWAY TO CREATE NEW CORRIDOR OPENINGS
O1P8 PROVIDE SEPERATE PRICING FOR NEW CORRIDOR BUILD -OUT AND DEMOLITION
DOOR SCHEDULE NOTES -
1. ALL DOORS ARE TO BE NEW BIRCH MOHAWK DOORS, PREFINISHED MAHOGANY.
2. ALL DOOR FRAMES, EXCEPT ENTRY DOOR TO BE 2" TIMELY FRAMES, PREFINISHED
LIGHT BEIGE (WE 508)
3. ENTRY WOOD DOOR FRAME TO BE STAINED TO MATCH BUILDING STANDARD MAHOGANY
4. PROVIDE NEW CHROME MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING
STANDARD WHERE NEEDED.
5. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION.
6. COORDINATE. KEYING LOCKSETS WITH TENANT.
7. RELOCATE EXISTING DOOR AND FRAME INTO VACANT SPACE TO NEW STORAGE 507.
8. NEW DOOR INTO REMAINING VACANCY TO BE INSTLLED AT NOTED LOCATION
WITH GLASS INSET AND FROSTED APPLIQUE.
1 /2"HW,
1 /2"CW,
& 1-1/4"V
i
J
CONNECT TO
BUILDING MAINS
2"W
f -TO BUILDING
PLUMBING
DRAIN
`ISOMETRIC
5A201 % SCALE: NTS
ue
REALTY CORPORATION
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone: (317) 808-6000
Fax: (317) 808-6797
cso
AfChiiec�ire
Ing
UM&Cape ArChlblCkIM
2" TIMELY
Six Parkwood Office
FRAME
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 ®Copyright 2001
_
3' BIRCH PRE-
t.�.1
_
FINISHED MAHOGANY^
LZ
C) Y9
MOHAWK DOOR
I v
e so
m�
oN
CD
�r
�N
a
LEVER
o 0
HARDWARE
DOOR ELEVATIONS
SCALE: 1/4" = 1'-0"
TYPICAL WALL TYPE—,
TYPICAL AT ALL EXTERIOR
WALLS- 5/8" TYPE X G.W.B.
FINISH BELOW EXISTING
WINDOW SILL COVER
METAL STUD
coat Ro
1� SECTION-
5A201 SCALE: 1/2"=1'-0"
n
J
3" WOOD FRAME
STAINED (WS1)
3' BIRCH STAINED (WS1
DOOR WITH 1/4" TEMP RED
GLASS INSET
LEVER
HARDWARE
D2
PREFINISHED ALUMINUM RECEIVER
TRIM "GB350" - FASTEN AT WINDOW
SILL & SET IN A CONTINUOUS BEAD OF
ACOUSTICAL SEALANT. TRIM COLOR
TO MATCH BLDG. WINDOW MULLIONS.
LINE OF EXISTING WINDOW SILL COVER
BELOW
CONTINUOUS
BEAD OF
ACOUSTICAL SEALANT
D AND SHELF
SII
WALL LEGEND
NOTE: ALL WALLS TO BE WALL TYPE (W1) UNLESS NOTED OTHERWISE
EXISTING CONSTRUCTION TO BE REMOVED
EXISTING PARTITION TO REMAIN
WX= NEW WALL CONSTRUCTION TO BE:
3
2-1/2- METAL STUDS @ 24" O.C. WITH 5/8"
GYPSUM BOARD EACH SIDE. WALLS TO
EXTEND TO UNDERSIDE OF CEILING LINE.
WX= NEW DEMISING WALL CONSTRUCTION TO BE:
2-1/2" METAL STUDS @ 24" O.C. WITH 5/8"
—71—
GYPSUM BOARD EACH SIDE. WALLS TO .
EXTEND TO UNDERSIDE OF CEILING LINE.
PROVIDE 2 1/2" SOUND INSULATION IN '
WALL AND ON HORIZONTAL SURFACE ABOVE
THE CEILING. INSULATION TO EXTEND
2'-0" IN BOTH DIRECTIONS FROM CENTER-
LINE OF WALL.
WX= NEW WALL CONSTRUCTION TO MATCH ADJACENT
CORRIDOR PARTITION CONSTRUCTION.
•
® DENOTES AREA NOT IN CONTRACT
DENOTES NEW MILLWORK
0 NEW DOOR AND FRAME.
REFER TO DOOR SCHEDULE.
CONSTRUCTION PLAN NOTES
FP1 ALIGN FINISHED FACES.
FP2 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS
USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION
FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT
BEFORE. PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 1/5A201.
FP3 NEW RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED i
IN WALL AT THIS LOCATION. PAINT TO MATCH ADJACENT WALL SURFACE.
6 COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE
FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MANUF. MANUAL.
UNDERCOUNTER REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE
FP5 POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQ. WITH MANUF. MANUAL.
PROVIDE 3/4" x 3'W x 5'L FIRE RETARDANT PLYWOOD PHONE BOARD. PHONE BD.
FPs PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT
WALL FINISH.
FP7 DEMO EXISTING WALL AND DOORWAY TO CREATE NEW CORRIDOR OPENINGS
O1P8 PROVIDE SEPERATE PRICING FOR NEW CORRIDOR BUILD -OUT AND DEMOLITION
DOOR SCHEDULE NOTES -
1. ALL DOORS ARE TO BE NEW BIRCH MOHAWK DOORS, PREFINISHED MAHOGANY.
2. ALL DOOR FRAMES, EXCEPT ENTRY DOOR TO BE 2" TIMELY FRAMES, PREFINISHED
LIGHT BEIGE (WE 508)
3. ENTRY WOOD DOOR FRAME TO BE STAINED TO MATCH BUILDING STANDARD MAHOGANY
4. PROVIDE NEW CHROME MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING
STANDARD WHERE NEEDED.
5. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION.
6. COORDINATE. KEYING LOCKSETS WITH TENANT.
7. RELOCATE EXISTING DOOR AND FRAME INTO VACANT SPACE TO NEW STORAGE 507.
8. NEW DOOR INTO REMAINING VACANCY TO BE INSTLLED AT NOTED LOCATION
WITH GLASS INSET AND FROSTED APPLIQUE.
1 /2"HW,
1 /2"CW,
& 1-1/4"V
i
J
CONNECT TO
BUILDING MAINS
2"W
f -TO BUILDING
PLUMBING
DRAIN
`ISOMETRIC
5A201 % SCALE: NTS
ue
REALTY CORPORATION
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone: (317) 808-6000
Fax: (317) 808-6797
cso
AfChiiec�ire
Ing
UM&Cape ArChlblCkIM
LOW &rAybv
Six Parkwood Office
600 East 96th Street, Suite 550
Indianapolis, Indiana 46240
317.848.7800
FAX 317.574.0957 ®Copyright 2001
c
0
O
Q
m0
e so
m�
T�
CD
�r
�N
a
a�
Z
Q
a
Z
0
Z
(�
W
L
Naz
H
Lc) 3
J
Y V)
Z
WOf-1
H<0
0
W
� Q
C)
CO)
U? _Q
C)
z0
Z
-
-
J
0
2
W
Certified By:
Drawing Number:
5A201
Of Sheets
Duke Job Number:
A/E Job Number:
21423S
FINISH PLAN NOTES FINISH LEGEND
1. ALL DOORS TO BE PREFINISHED BIRCH MOHAWK DOORS WITH MAHOGANY STAIN. FLOORCOVERINGS WALLCOVERING
2., ALL DOOR FRAMES TO BE PREFINISHED TIMELY; HOLLOW METAL, LIGHT BEIGE. MFG: MDC, LEN-TEX
3. ALL WOOD TRIM TO BE FINISHED TO MATCH NEW DOORS. C1 CARPET -DIRECT GLUE W1 PATTERN: CATALAN
O MFG: SHAW COMMERCIAL COLOR: BISON 1514 -CT
C�7 / 4. PROVIDE MINIBLINDS TO MATCH BUILDING STANDARD MINIBLINDS , AT ALL PATTERN: STRATUS TYPE II
PERIMETER AND INTERIOR WINDOWS. COLOR: 51520 ECLIPSE
5. PAINT PLYWOOD PHONE BOARDS WITH FIRE RETARDANT PAINT, COLOR O MFG: D.L. COUCH, VIN L FAB
TO MATCH ADJACENT WALL FINISH. C2 CARPET - DIRECT GLUE W2 PATTERN: PARCHMENT
MFG: J&J COMMERCIAL
CORRIDOR C4 B2l 6. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK, TO PATTERN: ASSURANCE COLOR: A04-114 DECLARATION BEIGE
°, . ' 508 FP1 O O • ANDARCHITECT/OR DESIGNER FOR REVIEW AND APPROVAL, BEFORE COLOR: 3108 BLUBERRY HILL TYPE 1
-17 =�= =+= Q 11V20 W3 FINISHES BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. DL
7. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING CARPET - DIRECT GLUE W3 MFG: D.L. COUCH, VERSA
• � � �• 'TRANSITIONS TO BE FEA HERED AS REQUIRED TO PROVIDE A SMOOTH C3 PATTERN: VIN L FAB
Ut 7,FPl I TRANSITION FROM FINISH TO FINISH PATTERN: 1 ASSURANCE COMMERCIAL COLOPE
A22-523
8. % G.C. TO SUBMIT LAYOUT DIAGRAMS, OF ALL NEW CARPETS IN PROJECT '
STAIR STORAGE B2 SCOPE FOR REVIEW AND APPROVAL BY ARHITECT ANDlOR DESIGNER COLOR: 1124 TARNISHED BRASS LOCATION: CORRIDOR'
T
#2 507 BEFORE PROCEEDING WITH FLOORING FINISH INSTALLA ION.
vCT2 P2 O CARPET -DIRECT GLUE PAINT ,
i a 9
'WHERE CARPET ANDIDE YL VINYL E REDUCER STRATRANSITIONS TOMAICH VINYL PLACE. BASE C4 MFG: SHAW COMMERCIAL
PATTERN: STRATUSP 1 MFG: ICI
COLOR: MOONGLOW 51220 COLOR: TBD
C4 g2 FPl CORRIDOR G B2 ,
LOCATION: CORRIDOR FINISH: EGGSHELL '
', W3 506 W3
P2 MFG: ICI
VINYL COMPOSITION TILE COLOR: SUDAN SAND 631
F I E�) FINISH: EGGSHELLNISH PLAN NOTES
MFG: ARMSTRONG ,
SERIES: IMPERIAL TEXTURE
C2 C1 W1 CONFERENC C2 FPi PROVIDE SEPERATE PRICING FOR CORRIDOR AND STORAGE FINISHES COLOR: 51805 CARMEL BEIGE
RECEPTION B1 501 Q PLASTIC LAMINATE
VCT2 VINYL COMPOSITION TILE
500 D MFG: MANNINGTON Pu MANUFACTURER: NEVAMAR
SERIES: ESSENTIALS COLOR: PDG -002T PAINTED WOODLANDS
C1 W1 COLOR: 143 FLAX FINISH: TEXTURED
Bt BASE
I _o•
S VINYL BASE
MANUFACTURER:
COVE BASE WOOD FINISH
VPI WOOD STAIN AND SPECIES TO MATCH
OFFICE COLOR: 14 TAUPE
WS1 MOHAWK PREFINISHED MAHOGANY DOORS
502 B2 VINYL BASE -4" COVE BASE
Pit C1 MANUFACTURER: JOHNSONITE
/7-1WORK RM C3 W2 / COLOR: 29 MOONROCK
FINISH PLAN
SCALE: 1/8"= 1'-0"
NORTH
EQUAL EQUAL LI, EQUAL
OR
1 LEVATION
5A801 J SCALE: 1/2"=1'-O"
IED LIGHT BEIGE
AE
SSS PANELS
s
N
• I
N
• / I LOWER CABINETS TO BE
_ TIMBERLAKE; BAINBRIDGE, WHITE
C _ WITH 4" CHROME WIRE PULLS
AND (2) ADJUSTABLE SHELVES
AND NO DRAWERS
M
BLOCKING IN
WALL AS REQ'D
4" VINYL
BASE (B1)
WORK RM
3 ELEVATION
5A801 SCALE: 1/2"=1'-0"
4 3
5A801 5A801
UPPER CABINETS TO BE
fIMBERLAKE; BAINBRIDGE WHITE
WITH 4" CHROME WIRE 15ULLS
AND (2) ADJUSTABLE SHELVES
25" dX 1-1 /2" PLASTIC
AMINATE (PL1) COUNTER
KITH 4" BACKSPLASH.
3'-0"
cso
ArdnUcture
'L.andecape Architecture
12-
2" TIMELY PREFINIS
HOLLOW METAL FRA
IN
//
UPPER CABINETS TO BE
0
a�
/1/2-
r
O
WITH 4' CHROME WIRE -PULLS
TEMPERED G
VM
too
AND (2) ADJUSTABLE SHELVES
cD
I
�9�
N
�
a
Y
(n
n
25" dX 1-1 2" PLASTIC'
U
LAMINATE (PL1) COUNTER
Z
WITH 4 BACKSPLASH.
0
I
2'- "
N
CL
STAINLESS STEEL DOUBLE
EQUAL EQUAL LI, EQUAL
OR
1 LEVATION
5A801 J SCALE: 1/2"=1'-O"
IED LIGHT BEIGE
AE
SSS PANELS
s
N
• I
N
• / I LOWER CABINETS TO BE
_ TIMBERLAKE; BAINBRIDGE, WHITE
C _ WITH 4" CHROME WIRE PULLS
AND (2) ADJUSTABLE SHELVES
AND NO DRAWERS
M
BLOCKING IN
WALL AS REQ'D
4" VINYL
BASE (B1)
WORK RM
3 ELEVATION
5A801 SCALE: 1/2"=1'-0"
4 3
5A801 5A801
UPPER CABINETS TO BE
fIMBERLAKE; BAINBRIDGE WHITE
WITH 4" CHROME WIRE 15ULLS
AND (2) ADJUSTABLE SHELVES
25" dX 1-1 /2" PLASTIC
AMINATE (PL1) COUNTER
KITH 4" BACKSPLASH.
3'-0"
5A801 % SCALE: 1/2"=1'-0"
8'-0"
2'-0" 3'- n UPPER CABINETS TO BE TIMBERLAKE;
BAINBRIDGE WHITE WITH 4" CHROME WIRE
PULLS AND (2) ADJUSTABLE SHELVES
io
COUNTER WITH 4' BACK PLMAISH NATE (PL1)
0
N LOWER CABINETS TO BE TIMBERLAKE;
BAINBRIDGE, WHITE WIT 4" CHROME WIRE
PULLS AND (1) ADJUS kBLE SHELF
TENANT
x
PROVIDED
O
i M 4" VINYL BASE
NOTE:
SINK TO BE DOUBLE B WL
STAINEESS STB ADDLE
3'-0" 2'-0" 3'- " HANDLE FAUCET.
7r ADA ACCESSIBLE SLANTED
PLASTIC LAMINATE L1PANELWIT3/4"
WORK RM PLASTIC LAMINATE (PL1) END PANELS
2 ELEVATION
5A801 J SCALE: 1/2"=1'-0"
ue
REALTY CORPORATION
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone: (317) 808-6000
Fax: (317) 808-6797
cso
ArdnUcture
'L.andecape Architecture
12-
Six Parkwood Office
IN
Indionopolis, Indiono 46240
UPPER CABINETS TO BE
0
a�
TIMBEROKE; BAINBRIDGE, WHITE
r
O
WITH 4' CHROME WIRE -PULLS
VM
too
AND (2) ADJUSTABLE SHELVES
cD
I
�9�
N
�
a
Y
(n
n
25" dX 1-1 2" PLASTIC'
U
LAMINATE (PL1) COUNTER
Z
WITH 4 BACKSPLASH.
0
I
2'- "
N
CL
STAINLESS STEEL DOUBLE
BOWL SINK WITH PADDLE
J
M
HANDLE HARDWARE
Q
X3/4" PLAS. LAM. (PL1)
C14
W'
REMOVABLE REMOVABLE PANEL
W
6 N
moo
O
'v) N
tv
06
VINYL BASE
WORK
RM
ELEVATION
5A801 % SCALE: 1/2"=1'-0"
8'-0"
2'-0" 3'- n UPPER CABINETS TO BE TIMBERLAKE;
BAINBRIDGE WHITE WITH 4" CHROME WIRE
PULLS AND (2) ADJUSTABLE SHELVES
io
COUNTER WITH 4' BACK PLMAISH NATE (PL1)
0
N LOWER CABINETS TO BE TIMBERLAKE;
BAINBRIDGE, WHITE WIT 4" CHROME WIRE
PULLS AND (1) ADJUS kBLE SHELF
TENANT
x
PROVIDED
O
i M 4" VINYL BASE
NOTE:
SINK TO BE DOUBLE B WL
STAINEESS STB ADDLE
3'-0" 2'-0" 3'- " HANDLE FAUCET.
7r ADA ACCESSIBLE SLANTED
PLASTIC LAMINATE L1PANELWIT3/4"
WORK RM PLASTIC LAMINATE (PL1) END PANELS
2 ELEVATION
5A801 J SCALE: 1/2"=1'-0"
ue
REALTY CORPORATION
600 East 96th Street
Suite 100
Indianapolis, IN 46240
Phone: (317) 808-6000
Fax: (317) 808-6797
cso
ArdnUcture
'L.andecape Architecture
Land 3un"by
Six Parkwood Office
600 East 96th Street, Suite 550
Indionopolis, Indiono 46240
317.848.7800
FAX 317.574.0957 ®Copyright 2001
0
a�
r
O
VM
too
�9�
iu N
a
�
a
Y
(n
n
M
U
Z
a
J
CL
J
Q
Q
Q
W
W
moo
O
V.
N 0 Z
06
=jw
W Ix
I-< o
Z
Wa-
—
Q
CO) Xz
(n Q
Q
o
Z
W
W
Z
Certified By:
Drawing Number:
5A8O1
Of Sheets
Duke Job Number:
A/E Job Number:
214235
0 Dom
SCALE: 1/811=1'-0"
GENERAL NOTES:
1.ALL DUCT GALVANIZED CONSTRUCTION
2.ALL NEW DUCT,FLEX,DIFFUSERS,GRILLES AND REGISTERS
3.TOILET EXHAUST AND OUTSIDE AIR, PROVIDED
BY SHELL HVAC CONTRACTOR.