Loading...
HomeMy WebLinkAbout1)f ckxmw Wan CV LEFT ELEVATION SCALE: 1/4 = 1-0 FRONT ELEVATION SCALE: 1/4" = V-0" cq 2e 01 C � N co co L� ) 'o� "o I() I() ,;INN n 7Z co 00 x� (0 vas W 1 �1//1111\� J tY O O DATE: 06/19/01 DRAWN eY: R-KRONICK SCALE: AS SHOWN REVISIONS: SHEET: 1 2e a1 Y 1�- .4- -41 I 1 Y II 1 II IF I 11 1 1 1 1 , L -'----------------------------1---------I 00 V1 K) Q n ot � o�coco I LL � Z) 7Z x a W r� C\4 O O DATE: 06/19/01 DRAWN BY: R.KRONICK SCALE: AS SHOWN REVISIONS: SHEET: 2 n GENERAL PLAN NOTES: 1) THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND JUDGE FOR THEMSELVES, THE SUITABILITY OF THE PLANS IN RELATIONSHIP TO THE BUILDING SITE, AND EXISTING GRADES, 2) THESE DRAWINGS SERVE AS A GUIDE TO THE CONSTRUCTION OF THE BUILDING, DUE TO VARIATIONS IN DIFFERENT AREAS, THEY CAN ONLY BE A GUIDE, AND IN NO WAY DICTATE ANY OF THE LOCAL AND/ OR STATE BUILDING CODES. IT IS THE CONTRACTORS FULL RESPONSIBILITY TO REVIEW ALL PLANS FOR ACCURACY AND CLARITY, AND TO INSURE ALL SUBS ARE CLEAR AS TO THE SCOPE OF THEIR WORK. THE CONTRACTOR ASSUMES ALL RESPONSIBILITY FOR ERRORS IN DESIGN, DIMENSIONS OR OMISSIONS, 3) ALL STRUCTURAL MEMBERS ARE BASED ON AN ASSUMED NEED, AND MAY CHANGE AT ANY TIME, IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ACTUAL NEED AND SIZES IF NOT SHOWN, 4) ALL WINDOW SIZES LISTED ARE BASIC GLASS SIZES AND MAY VARY BASED ON SUPPLIER, ALL FINISHES AND ROUGH OPENINGS MUST BE VERIFIED BY OWNER/ CONTRACTOR. 5) ALL WALLS W/ BRICK ARE 1-1/2", ALL OTHERS TO BE 3-1/2" UNLESS NOTED OTHERWISE ON PLANS. 6) ALL CEILINGS ARE S' MAIN LEVEL AND 8' UPPER LEVEL OR AS NOTED ON PLAN FOR GIVEN AREA. l) ALL DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE CONTRACTOR/ DESIGNER IMMEDIATELY BEFORE CONSTRUCTION IS TO RESUME, TO INSURE PROPER STEPS ARE TAKEN. MAIN FLOOR PLAN SCALE: 1/4" = 1'-0" 2560 S.F. N CO co a0 'tI� w J �o j2j��00 00 O �I-j x LA oQ7�>< 85'-4" 13'-4" 5'-0" x 5'-0" 5'-0" x 5'-0"7n �) x W r -�'r u BREAKFAST NOOK 2 -6 x 5 -6 6-0 xco 4 20 - 2 c 2'-6" x 4'-0" 14'-i" 5'-0" x 5'-0" PRE -CAST GAS L cIf��------ I D/W - ----- Q r, — --- D/1/ FIREPLACE 9'-5y2° ; 28'-4" 14'-11l�" 13'-OV2" V t O - LAUNDRY , O a = i O 0:0 ° FAMILY ROOM Q Y O : 0 o _ HEARTH ROOM OPEN TO ABOVE O'O ISLAEl ND OFFICE _ 4 _ x-------------- COATS �n 2'-4" - r I GAR GARAGE _ z --------04 ---------- — n--/ REFRIG------- w--- -- d. Q m tu -11 ____- ir —\=o: OVENS r L —L=1 _ be W CA 5'-0" x 5'-6" 14'-1015" 1 24'-0" 20'-9" 21-4" 1'-Z 2'-4" 13'-4" v O tr ' Cloe O � J W� ( O J 0 C4 4 DATE: 06/19/01 DRAWN BY: R-KRONICK SCALE: AS SHOWN REVISIONS: SHEET: 3 J FOUNDATION PLAN SCALE: 1/4" = 1'—OI' GENERAL F0UNDATI0N NOTES: 1) ALL SOIL IS BASED ON 2800 P.S.F., AND CONCRETE IS BASED ON 2800 P.S.I. is 28 DAYS, FOOTERS ARE 16" WIDE AND 8" DEEP UNLESS NOTED OTHERWISE ON PLANS, 2) BASEMENT WALL HEIGHT AS NOTED ON PLANS, W/ SHORT WALLS 9 CRAWL SPACE OR SLAB BELOW FROST LINE AS REQUIRED, 3) THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND JUDGE FOR THEMSELVES, THE SUITABILITY OF THE PLANS IN RELATIONSHIP TO THE BUILDING SITE, AND EXISTING GRADES. 4) THESE DRAWINGS SERVE SA A GUIDE TO THE CONSTRUCTION OF THE BUILDING, DUE TO VARIATIONS IN DIFFERENT AREAS, THEY CAN ONLY BE A GUIDE, AND IN NO WAY DICTATE ANY OF THE LOCAL AND/ OR STATE BUILDING CODES. IT IS THE CONTRACTORS FULL RESPONSIBILITY TO REVIEW ALL PLANS FOR ACCURACY AND CLARITY, AND TO INSURE ALL SUBS ARE CLEAR AS TO THE SCOPE OF THEIR WORK. THE CONTRACTOR ASSUMES ALL RESPONSIBILITY FOR ERRORS IN DESIGN, DIMENSIONS OR OMISSIONS. 8) ALL STRUCTURAL MEMBERS ARE BASED ON AN ASSUMED NEED, AND MAY CHANGE AT ANY TIME, IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ACTUAL NEED AND SIZES IF NOT SHOWN, 60 ALL WINDOW SIZES LISTED ARE AS MANUFACTURED BY SEMCO WOOD PRODUCTS, UNLESS NOTED OTHERWISE, AND MAY VARY BASED ON SUPPLIER, ALL FINISHES AND ROUGH OPENINGS MUST BE VERIFIED BY OWNER/ CONTRACTOR. 1) ALL WALLS W/ BRICK ARE 1-1/2", ALL OTHERS TO BE 3-1/2" UNLESS NOTED OTHERWISE ON PLANS. 8) ALL CEILINGS ARES' MAIN LEVEL AND 8' UPPER LEVEL OR AS NOTED ON PLAN FOR GIVEN AREA. 3) ALL DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE CONTRACTOR IMMEDIATELY BEFORE CONSTRUCTION IS TO RESUME, TO INSURE PROPER STEPS ARE TAKEN. O t— cq I ctrl N N 15'-0" 23'-0" 86'—O%b" 15'-411 9111 32'—OW1 i0'404" t------------------------------------------------ s ---1 v -------------------------------------- �-------------- -------------------•)I------r------------------------------- ____________________________________a______I-____-______-___________________------------ - ' ' DROP BEAM 1 77 --------------t v o ___________ '---------------- ------------------------ WET BAR vv - . - , -K7 —r---------------------------------------------------�- - - o v v . v_ v o ----------------- ------------------------------------------ ---------- ------------------1 ----------------------- ; I FORGED WALK OUT I---------------- L_ _ _ _ _ _ J i ' 1 , 1 I - ------------------------------ J�-- , SLOPE SLAB TO DRAIN 1 . I • 1 ' I 1 I 1 I 1 1 DRAIN TO SUMP THRU SLEEVE --"--------------------------- I � � I IN WALL b" BELOW BRICK LEDGE 1 1 , 12" CRAWL ------------------ --+ - -4-4--4--# -------- - - - - -- i 1 TIMBER WINDOW WELL FRIG. CONNECT "T" TO INSIDE TILE AND :x W/ ALL POCKETS BY ; 1 STUB OUT 8" I ' I ' p CONCRETE WALL CONT. CONCRETE SLAB i i I i iIq , - 4 EXTERIOR MUST 8" POURED 45'-4V2" a , BE 4" BELOW CONCRETE , 1 4. 04 ENT WALL WITH 1 I • ; i x 4'" I " x 4'" 2'-6" -0 ' ' 2'-6" x 4'-0" 6'-0 -0 BAASB BRICK GAP i i cel i ---------------- ------------- ------ ------ 1 1 1 I '--------------------------------------- --------------- Q I ----- --- 1 L_� - - L- - - ''- - - L- - al °• I I I I I 1 1 I 1 I 1 I 4" MIN. PEA FILL OVER I ' ; 6 MIL POLY VAPOR BARRIER 1 1 1- 1\/ I I 1 I 1 1 I 1 I 1 I 1 1 , N 1 I0 0 I t 1 I 1 I I I I I 1 1, •> 1 1 T 4" DIA. STEEL POST ON I 1 �► I /\ I I 1 1 1 1 1 I 1 I I I; 24"X24"Xl8" CONC. PAD ' , SCALE: 1/4" = V—O" 2103 S.F. --------------------------------------------------------------------------------------------- I Q v o - L s ---1 v , , 1 �-------------- -------------------•)I------r------------------------------- ____________________________________a______I-____-______-___________________------------ - ' ' DROP BEAM 1 77 --------------t v o ___________ '---------------- ------------------------ WET BAR vv - . V - - o v v . v_ v ----------------- ------------------------------------------ ---------- ------------------1 _________________________________I ------------- I DROP BEAM L_ _ _ _ _ _ J i ' 1 , --------------------------------1- -- - - - - - - -- --- --- ---------- ---- - - -- -- ------------------ - ------------------------------ J�-- , I 1 _ 1 I 1 ' 1 1 1 1 --"--------------------------- I r 1 1 , 12" CRAWL ------------------ --+ - -4-4--4--# -------- - - - - -- i 1 FRIG. � WALL HT. 1 dd , I 1 1 I I I 1 I 1 1 I 1 - 1 RECREATION ROOM , I I 14'-4" , - 1 23'-3�" 45'-4V2" a , 1 , 1 4. 04 a I 1 , I • 1 1 1 1 1 1 1 1 1 1 1 1 I 1 `� CRAWL SPACE ---------------------------------------- 1 4" MIN. PEA FILL OVER I ' ; 6 MIL POLY VAPOR BARRIER 1 1 VENTILATION AS REQUIRED ; ' - 5ASEMENT LAYOUT 1 ' , SCALE: 1/4" = V—O" 2103 S.F. I 1 • I 1 , , I I 1 1 1 I 1 IL 1 1 1 ' 1 '° L ------------------------------------------------------- ----- 1 1 • 1 � a a L----------------------- I ---------------------------- SLOPE SLAB TO DOOR s ---1 ° , , 1 4" DIA. STEEL POST ON ; 24"X24"XIS" CONC. PAD WET BAR DROP BEAM i I t. DROP BEAM 44 i ' 1 , --------------------------------1- -- - - - - - - -- --- --- ---------- ---- - - -- -- ------------------ - ------------------------------ J�-- , I 1 _ 1 '° 1 ' T- - ----------------- --"--------------------------- I r 1 1 ,(1 ------------------ --+ - -4-4--4--# -------- - - - - -- i 1 FRIG. � °► 1 dd , I 1 1 I I I 1 I 1 1 I 1 - 1 I I , I I I I 1 , - 1 i I 1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7 , 1 , 1 4. 04 1 1 I • 1 1 1 1 1 1 1 1 1 1 1 1 I 1 `� ---------------------------------------- I ccl TIMBER WINDOW WELL W/ ALL POCKETS BY CONCRETE WALL CONT. z C� z � N coo co W Q p N zCcoao n Ln Ll Q0 : Q U li DATE: 06/19/01 DRAWN 5Y: R-KRONIOK SCALE: AS SHOWN REVISIONS: SKEET: 5 I 1 t. ii I 1 Ih 1 1 -x I 1 I r 1 1 ,(1 1 1 � ' 1 I I I I 1 1 i I 1 I 04 ccl TIMBER WINDOW WELL W/ ALL POCKETS BY CONCRETE WALL CONT. z C� z � N coo co W Q p N zCcoao n Ln Ll Q0 : Q U li DATE: 06/19/01 DRAWN 5Y: R-KRONIOK SCALE: AS SHOWN REVISIONS: SKEET: 5 1