Loading...
HomeMy WebLinkAbouta00806 01 02 03 04 05 HEEL CUT VARIES 16" O.H. OR GREATER HARDBOARD FRIEZE - w/ 1 5 8" BARGE MOULD - TRIM TO MATCH WINDOW HEADER HEIGHTS 1x8 GUTTER BOARD - w/ ALUMINUM GUTTER 2x4 FLAT NAILER @ 48" o.c. - AVOID ALUMINUM VENTS 3/8" SOFFIT - w/ ALUMINUM VENT @ 48" o.c. 2x2 NAILER 3/4" = 1'-0" BLOCKING @ OVERHANG SCALE: DETAIL - SECTION - BOX RETURN 1x8 GUTTER BOARD, TYP. 1x TRIM, TYP. BRICK VENEER, TYP. HARDBOARD FRIEZE - REFER TO ELEVATIONS FOR SIZES AND PROFILES FIBERGLASS ASPHALT SHINGLES OVER 7/16" ROOF SHEATHING METAL FLASHING, TYP. ALUMINUM GUTTER SHOWN DASHED - REFER TO ELEVATIONS SCALE: 3/4" = 1'-0" VARIES PER PITCH VARIES SEE PLAN SECTION - BOX RETURN 1x8 GUTTER BOARD, TYP. 1x TRIM, TYP. CULTURED STONE VENEER, TYP. HARDBOARD FRIEZE - REFER TO ELEVATIONS FOR SIZES AND PROFILES FIBERGLASS ASPHALT SHINGLES OVER 7/16" ROOF SHEATHING METAL FLASHING, TYP. ALUMINUM GUTTER SHOWN DASHED - REFER TO ELEVATIONS SCALE: 3/4" = 1'-0" VARIES PER PITCH VARIES SEE PLAN VARIES SECTION - BOX RETURN 1x8 GUTTER BOARD, TYP. 1x TRIM, TYP. HORIZONTAL SIDING, TYP. HARDBOARD FRIEZE - REFER TO ELEVATIONS FOR SIZES AND PROFILES FIBERGLASS ASPHALT SHINGLES OVER 7/16" ROOF SHEATHING METAL FLASHING, TYP. ALUMINUM GUTTER SHOWN DASHED - REFER TO ELEVATIONS SCALE: 3/4" = 1'-0" VARIES PER PITCH SEE PLAN SCALE: 1 1/2" = 1'-0" SUPPORTED BY ROOF TRUSS DETAIL - BRICK VENEER REFER TO GENERAL NOTES FOR SIZE OF LINTEL METAL COUNTER FLASHING - SET INTO BRICK & ONTO STEP FLASHING ROOF TRUSS ICE & WATER SHIELD - 36" WIDE, 12" UP WALL & 24" ONTO ROOF - INSTALLED BEHIND & UNDER STEEL LINTEL STEP FLASHING 2" MIN. OVERLAP NOTE: TRUSS MANUFACTURER TO SIZE TRUSS FOR ADDITIONAL BRICK LOADING SCALE: 3/4" = 1'-0" BRICK VENEER, TYP. HARDBOARD FRIEZE - REFER TO ELEVATIONS FOR SIZES AND PROFILES 1x8 GUTTER BOARD, TYP. ALUMINUM GUTTER - REFER TO ELEVATIONS FIBERGLASS ASPHALT SHINGLES OVER 7/16" ROOF SHEATHING CULTURED STONE VENEER, TYP.  +2/' 2)) 7 6+,1*/(6 “ METAL FLASHING - TURN OUT 3" ABOVE GUTTER @ STONE VENEER DETAIL - FLASHING 7'-4" OR GREATER DETAIL - GABLE TRUSS BRACING SCALE: BOTTOM CHORD THAT EXCEEDS BETWEEN ANY TOP CHORD AND #3 SPF OR BETTER IS REQUIRED 'L' BRACE CONSISTING OF (1) 2x4 FURRING w/ 12d NAILS @ 8" o.c. 7'-4" 1/2" = 1'-0" 2x4 'L' BRACE NAILED TO 2x4 2x4 GABLE STUD WOOD TRUSS A BRACE SECTION A SCALE: 1" = 1'-0" DETAIL - GABLE RETURN SCALE: 1/2" = 1'-0" GABLE EXTENSION - 2x8 BLOCKS @ 24" o.c. ON 1x6 - REFER TO ELEVATION FOR EXTENSION FROM FRAME WALL 1x GABLE FRIEZE - w/ BARGE MOULD - REFER TO ELEVATION FOR 1x RAKE BOARD FIBERGLASS / ASPHALT SHINGLES 1x8 GUTTER BOARD - w/ ALUMINUM GUTTER 2x4 NAILER 2x4 RAFTER 2x4 RAFTER TIE PRE-ENGINEERED TRUSSES @ 24" o.c. VARIES REFER TO ELEVATION DBL. 2x4 TOP ⅊ BACK-UP / EXTENSION FROM FRAME WALL - REFER TO ELEVATION FOR SIZE - REFER TO ELEVATION FOR SIZE SCALE: 3/4" = 1'-0" 1x4 TRIM FROM CRICKET UP ROOF EXTEND ICE & WATER GUARD AROUND BACK OF CRICKET WRAP ICE & WATER GUARD (UNDER SHINGLES) TO EXTEND SLOPE OF ROOF OF CRICKET 1x4 TRIM SLOPE 2x4 FRAME WALLS ICE & WATER GUARD CRICKET - EXTEND 2" BEYOND BRICK 2" FROM FACE OF VENEER 2 FEET UP WALL ROOF CRICKET - BRICK DETAIL - FRAME DIMENSION REFER TO FLOOR PLAN ROOF CRICKET - SIDING SCALE: 3/4" = 1'-0" 1x4 TRIM FROM CRICKET UP ROOF EXTEND ICE & WATER GUARD AROUND BACK OF CRICKET WRAP ICE & WATER GUARD (UNDER SHINGLES) TO EXTEND SLOPE OF ROOF OF CRICKET 1x4 TRIM SLOPE 2x4 FRAME WALLS ICE & WATER GUARD CRICKET FRAME DIMENSION REFER TO FLOOR PLAN 2 FEET UP WALL - EXTEND 2" BEYOND TRIM 2" FROM FACE OF TRIM DETAIL - WINDOW OPENING 2x4 BLOCKING - INSTALL BLK'G FLAT, - ALIGN AS SHOWN @ EACH SIDE FLUSH w/ OUTSIDE OF FRAME WALL WINDOW HEADER VARIES VARIES BTM/ WDW R.O. R.O. R.O. T/ WDW ℄ WDW DETAIL - SHUTTER BLOCKING @ SIDING SCALE: 3/8" = 1'-0" WINDOW OPENING 2x4 BLOCKING - INSTALL BLK'G FLAT, - ALIGN AS SHOWN @ EACH SIDE FLUSH w/ OUTSIDE OF FRAME WALL WINDOW HEADER NOTE: PROVIDE 6" SHUTTER ANCHORS TO PENETRATE INTO BLOCKING THROUGH CULTURED STONE VENEER SHUTTER INSTALLED OVER TOP OF CULTURED STONE VENEER VARIES VARIES BTM/ WDW R.O. R.O. R.O. T/ WDW ℄ WDW BLOCKING @ CULTURED STONE SCALE: 3/8" = 1'-0" DETAIL - SHUTTER SCALE: 1" = 1'-0" 1x2 SYNBOARD TRIM 1x TRIM - EXTEND 1" BEYOND 1x BEVELED TRIM - PROVIDE 1" x 1" NOTCH @ EACH END 1" 1 5 8 " 5 8 1" " FOR FCB SIDING - REFER TO ELEVATIONS FOR SIZES AND PROFILES - w/ 10° BEVEL DRIP EDGE - NAIL & TAPE TO SHEATHING - USE 1" ROOFING NAILS 10.00° - FIBER CEMENT SIDING DETAIL - 1x WINDOW HEAD SCALE: 1" = 1'-0" 1x2 SYNBOARD TRIM 1x TRIM - EXTEND 1" BEYOND 1x BEVELED TRIM - PROVIDE 1 1/8" x 1" NOTCH @ EACH END 1" 1 5 8 " 1 2 1 " 1 8 " FOR J-CHANNEL - REFER TO ELEVATIONS FOR SIZES AND PROFILES - w/ 10° BEVEL DRIP EDGE - NAIL & TAPE TO SHEATHING - USE 1" ROOFING NAILS 10.00° - VINYL SIDING DETAIL - 1x WINDOW HEAD SCALE: 1" = 1'-0" 1x2 SYNBOARD TRIM 1x TRIM - EXTEND 1" BEYOND 1x BEVELED TRIM - PROVIDE 1" x 1" NOTCH @ EACH END 1" 1 5 8 " 5 8 1" " FOR FCB SIDING - REFER TO ELEVATIONS FOR SIZES AND PROFILES - w/ 10° BEVEL 10.00° - FIBER CEMENT SIDING DETAIL - 1x WINDOW SILL SCALE: 1" = 1'-0" - VINYL SIDING 1x2 SYNBOARD TRIM 1x TRIM - EXTEND 1" BEYOND 1x BEVELED TRIM - PROVIDE 1 1/8" x 1" NOTCH @ EACH END 1" 1 5 8 " 1 2 1 " 1 8 " FOR J-CHANNEL - REFER TO ELEVATIONS FOR SIZES AND PROFILES - w/ 10° BEVEL 10.00° DETAIL - 1x WINDOW SILL HEAD w/ VINYL SIDING HORIZONTAL SIDING, TYP. SCALE: 1 1/2" = 1'-0" DETAIL - FYPON WINDOW FYPON WINDOW CROSSHEAD - REFER TO ELEVATION FOR SIZE & PROFILE J-CHANNEL TRIM, TYP. DRIP EDGE - SET IN BED OF SEALANT - NAIL & CAULK TO SHEATHING - USE 1" ROOFING NAILS 1x6 EXT. TRIM BACK-UP METAL FLASHING 07 08 09 10 11 12 13 14 16 17 18 FIBER CEMENT BOARD SIDING, TYP. SCALE: 1 1/2" = 1'-0" FYPON WINDOW CROSSHEAD - REFER TO ELEVATION FOR SIZE & PROFILE METAL FLASHING w/ FIBER CEMENT SIDING DETAIL - FYPON WDW HEAD 19 SCALE: 1 1/2" = 1'-0" DETAIL - EXTENDED REVERSE GABLE GABLE EXTENSION - FOR 1x8 RAKE: 2x6 BLOCKS @ 24" o.c., ON 1x6's - FOR 1x10 RAKE: 2x8 BLOCKS @ 24" o.c., ON 1x8's 1'-4" FIBERGLASS / ASPHALT SHINGLES - w/ 15# ROOF FELT 1x8 or 1x10 RAKE BOARD - REFER TO ELEVATION STRUCTURAL SHEATHING GABLE END TRUSS 7/16" ROOF SHEATHING 3/8" SOFFIT NOTE: GABLE EXTENSION STIFFENERS - 2x4's TURNED FLAT. NOTCH GABLE END TRUSS & 1x4 LADDER RAIL. EXTEND AND NAIL TO 1st RAFTER. NOTE: FRIEZE BOARD AND VENEER NOT SHOWN - REFER TO ELEVATION 20 21 22SCALE: 1/2" = 1'-0" T/ PORCH SLAB 10 3 4 " 11 1 4 " 10 3 4 " 11 1 4 " 2x12 TREATED COLUMN BASE 8x8 COMPOSITE COLUMN BASE - INSTALL PER MAN'F'S INSTRUCTIONS 2x10 P.T. BLOCKING - ALL SIDES FLUSH w/ COLUMN 3/8" Ø ANCHOR OR EXPANSION BOLT 2x2 BLOCKING 2x10 BLOCKING @ T/ COLUMN 1x12's 1x10's (2) 2x4's @ OUTER FRONT CORNER DETAIL - 12" BOX COLUMN TOP & BASE SCALE: 1/2" = 1'-0" T/ PORCH SLAB 7" 7 1 4 " 7" 7 1 4 " 2x8 TREATED COLUMN BASE 8x8 COMPOSITE COLUMN BASE - INSTALL PER MAN'F'S INSTRUCTIONS 2x6 P.T. BLOCKING - ALL SIDES FLUSH w/ COLUMN 3/8" Ø ANCHOR OR EXPANSION BOLT 1x8's 1x6's 2x2 BLOCKING 2x6 BLOCKING @ T/ COLUMN (2) 2x4's @ OUTER FRONT CORNER DETAIL - 7" BOX COLUMN TOP & BASE SCALE: 1/2" = 1'-0" T/ PORCH SLAB 8 3 4 " 9 1 4 " 8 3 4 " 9 1 4 " 2x10 TREATED COLUMN BASE 8x8 COMPOSITE COLUMN BASE - INSTALL PER MAN'F'S INSTRUCTIONS 2x8 P.T. BLOCKING - ALL SIDES FLUSH w/ COLUMN 3/8" Ø ANCHOR OR EXPANSION BOLT 1x10's 1x8's DETAIL - 9" BOX COLUMN TOP & BASE 2x2 BLOCKING 2x8 BLOCKING @ T/ COLUMN (2) 2x4's @ OUTER FRONT CORNER SCALE: 1 1/2" = 1'-0" DETAIL - BRICK SOLDIER COURSE STEEL LINTEL - REFER TO SHEET GN FOR SIZE BRICK SOLDIER COURSE - PULL 1 2" FROM FACE OF VENEER - ALTERNATE ROWLOCK & SOLDIER ACROSS HEADER 5 7 8 " 3 8 " 2 3 4 " 1 2" 23 W I L L I A M L . K A U F H O L Z A R C H I T E C T TALLYNS RIDGE REASON FOR PLOT: PLOT DATE: Job No. Sheet No. HOMESITE NO. IN OFFICE REVIEW: MASTER BY: DATE: C DATE: 3940 OLYMPIC BLVDERLANGER, KY 41018 PH: (859) 341-4709 FIELD SPEC HOTLINE: (859) 341-4709 COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc. JOB INFO: DATE: PERMIT: SIGN-OFF: CONSTRUCTION: REVISION: REVISION: REVISION: REVISION: HOME TYPE: PLAN: # 9/28/2018 2:29 PM TLR010140000 GOPI VINOD AVVARI 1 4344 TRAHAN DRIVE PAXTON 57-500-PAXTON ENGLISH ELEGANCE WITH BRICK & STONE CARMEL, IN 1 4 05/201 7 JMP/TJE ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- fieldspecchange@fischerhomes.com KAVYA AVVARI REVISED BY:---- SAPPHIRE TRADE SUPPORT sapphiretradepartners@fischerhomes.com Fischer Homes Indianapolis II, LLC f/k/a Fischer Homes Indianapolis II, L.P. D1.0 10/08/18 William Hohlt