18100085 Truss Plans
Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). Liu, Xuegang Pages or sheets covered by this seal: I34850455 thru I34850501 My license renewal date for the state of Indiana is July 31, 2020. B18802916 Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. IMPORTANT NOTE: CALA 46 CLAY 16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. October 3,2018 Job B18802916 Truss GE03 Truss Type Common Supported Gable Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850455 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:45 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-vpWWs7XH9CfyhdyPfG86j1rbulxqHs9qCrhjdqyXBC0 Scale = 1:66.4 Sheet Back Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 4x6 3x4 5x6 2x4 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 Job B18802916 Truss GE04 Truss Type GABLE Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850456 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:46 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-N04u3SYvwWnpJmXbDzgLFENjP86f0FV_QVRH9HyXBC? Scale = 1:69.2 Sheet Front Left Option 2-11-0 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 13 12 11 10 9 14 15 16 17 4x6 3x4 5x8 3x6 3x8 2x4 3x6 3x6 3x6 3x6 2x4 2x4 3x6 2x4 3x8 2x4 5x8 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 Job B18802916 Truss GE05 Truss Type Common Supported Gable Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850457 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:48 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-JOCfU8a9R71XY4h_LOipKfT53yyQUE9HupwOD9yXBBz Scale = 1:59.3 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 36 35 34 33 32 31 30 29 28 2726 25 24 23 22 21 20 3x6 4x6 3x4 3x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 Job B18802916 Truss GE07 Truss Type GABLE Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850458 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:49 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-nbm1hUanCR9OAEGAu6D2tt?9tM9EDe2Q6TfxlcyXBBy Scale = 1:93.2 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 12 3 4 5 6 7 8 9 10 11 12 13 14 15 16 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 33 17 3x6 6x8 3x6 3x6 3x6 4x8 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 Job B18802916 Truss GE08 Truss Type GABLE Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850459 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:50 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-FnKPvqbQzkHFoOrMSpkHQ4YN2mbqy3yZL7PUH2yXBBx Scale = 1:89.7 Sheet Back Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 39 20 6x8 3x6 3x6 3x6 6x8 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 Job B18802916 Truss GE09 Truss Type Monopitch Supported Gable Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850460 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:51 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-jztn6Ac2k2P6PYQZ0XFWyI4cx9_BhbUjan82pUyXBBw Scale = 1:40.2 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x4 3x4 3x4 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 15-10-1 -0-11-4 0-11-4 13-2-12 13-2-12 0-6-8 7-1-14 6.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-1], [2:0-2-9,Edge] LOADING (psf) Job B18802916 Truss GE11 Truss Type Monopitch Supported Gable Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850461 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:51 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-jztn6Ac2k2P6PYQZ0XFWyI4cz9z6hcojan82pUyXBBw Scale = 1:29.2 Sheet Back Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 12 11 10 9 8 7 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 6-7-15 5-11-8 5-11-8 1-10-2 4-9-14 6.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 Job B18802916 Truss GE12 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850462 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:52 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-CAR9KWdgVMXy1h_laEnlVVdqVZLYQ3vspRubMxyXBBv Scale = 1:8.8 Sheet Back Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 2x4 2x4 2x4 2-7-14 2-4-10 2-4-10 0-0-4 1-2-5 6.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.09 0.06 0.00 DEFL. Vert(LL) Job B18802916 Truss GE18 Truss Type Common Supported Gable Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850463 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:53 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-gM?YXseIGffpfrZx7xI_1jAySzfZ9U5015d9uNyXBBu Scale = 1:67.8 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 28 27 26 25 24 23 22 21 20 19 18 17 16 3x4 3x6 4x6 3x6 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 Job B18802916 Truss GE19 Truss Type Monopitch Supported Gable Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850464 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:53 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-gM?YXseIGffpfrZx7xI_1jA?Zzh59W9015d9uNyXBBu Scale = 1:11.8 Sheet Back Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 2x4 2x4 2x4 -0-11-4 0-11-4 1-11-8 1-11-8 0-4-7 1-8-2 8.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.07 0.04 0.00 DEFL. Job B18802916 Truss GE19A Truss Type Monopitch Supported Gable Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850465 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:54 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-8YZwkBew1zogG?87hfpDawiAJN1KuzP9GlNiQpyXBBt Scale = 1:11.8 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 2x4 2x4 2x4 -0-11-4 0-11-4 1-11-8 1-11-8 0-4-7 1-8-2 8.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.07 0.04 0.00 DEFL. Job B18802916 Truss GE20 Truss Type Monopitch Structural Gable Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850466 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:54 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-8YZwkBew1zogG?87hfpDawi8gN0yuzP9GlNiQpyXBBt Scale = 1:18.2 Sheet Back Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 5 4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 -1-3-4 1-3-4 4-11-8 4-11-8 1-10-0 3-0-14 2-9-6 0-3-8 3-0-14 3.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 Job B18802916 Truss GE21 Truss Type Scissor Supported Gable Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850467 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:55 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-cl7IyXfYoHwXu9jKFMKS78FHgnLSdNgJVP6FyFyXBBs Scale = 1:60.7 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 28 27 26 25 24 23 22 21 20 19 18 17 16 3x4 3x6 4x6 3x4 3x6 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 Job B18802916 Truss GE22 Truss Type Common Supported Gable Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850468 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:57 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-Y7F2NDhpKuAF8TtiMnMwCZKida2C5IhbyibM18yXBBq Scale: 3/16"=1' Sheet Back Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 4x6 3x4 3x8 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 Job B18802916 Truss M03 Truss Type Monopitch Qty 8 Ply 1 CALA 46 CLAY Job Reference (optional) I34850469 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:57 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-Y7F2NDhpKuAF8TtiMnMwCZKcMav55EzbyibM18yXBBq Scale = 1:78.5 1 2 3 4 5 10 9 8 7 6 11 12 3x6 4x8 3x4 3x6 3x4 3x6 4x8 3x4 3x6 3x6 3x6 3x6 9-3-8 9-3-8 18-7-0 9-3-8 6-3-8 6-3-8 12-3-8 6-0-0 18-7-0 6-3-8 5-2-2 14-5-10 2-9-4 14-5-10 6.00 12 Plate Offsets (X,Y)-- [5:0-4-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 Job B18802916 Truss M04 Truss Type Monopitch Qty 10 Ply 1 CALA 46 CLAY Job Reference (optional) I34850470 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:58 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-0JpRaZhR5CI6lcSvwVt9kmtg3_9gqaZlBMLwZayXBBp Scale = 1:78.5 1 2 3 4 5 10 9 8 76 11 12 3x6 4x8 3x8 3x6 3x6 3x6 5x8 3x6 4x8 3x6 3x6 11-9-0 11-9-0 23-2-8 11-5-8 23-3-0 0-0-8 7-10-3 7-10-3 15-4-13 7-6-11 23-3-0 7-10-3 2-10-2 14-2-2 14-5-10 8-4-14 14-5-10 6.00 12 Plate Offsets (X,Y)-- [5:0-4-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 Job B18802916 Truss M05 Truss Type MONOPITCH Qty 3 Ply 1 CALA 46 CLAY Job Reference (optional) I34850471 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:58 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-0JpRaZhR5CI6lcSvwVt9kmtoD_Huqb6lBMLwZayXBBp Scale = 1:39.6 1 2 3 4 5 7 6 2x4 4x8 3x4 5x6 3x4 5x6 7-5-9 7-5-9 13-2-12 5-9-3 -0-11-4 0-11-4 7-5-9 7-5-9 13-2-12 5-9-3 0-6-8 7-1-14 4-10-6 2-3-8 5-1-14 2-0-0 6.00 12 3.50 12 Plate Offsets (X,Y)-- [2:0-2-9,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Job B18802916 Truss M08 Truss Type Monopitch Qty 10 Ply 1 CALA 46 CLAY Job Reference (optional) I34850472 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:59 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-UWMpovi3sVQzNm15UCPOH_QypOguZEeuQ04T61yXBBo Scale = 1:27.8 1 2 4 3 3x4 3x6 3x4 3x6 5-11-8 5-11-8 1-10-2 4-9-14 4-6-6 0-3-8 4-9-14 6.00 12 Plate Offsets (X,Y)-- [3:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.40 0.27 0.00 Job B18802916 Truss M11 Truss Type Monopitch Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850473 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:00:59 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-UWMpovi3sVQzNm15UCPOH_QySObmZ28uQ04T61yXBBo Scale = 1:36.5 1 2 3 6 5 4 5x6 2x4 5x6 3x4 3x4 7-5-9 7-5-9 13-2-12 5-9-3 7-5-9 7-5-9 13-2-12 5-9-3 0-6-8 7-1-14 5-1-14 2-0-0 6.00 12 3.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. Job B18802916 Truss M12 Truss Type Monopitch Qty 4 Ply 1 CALA 46 CLAY Job Reference (optional) I34850474 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:00 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-ziwB?FjhdpYq?wcH2vwdqBy7zoxSIWA2egq0eTyXBBn Scale = 1:36.5 1 2 3 6 5 4 4x8 3x4 5x6 3x4 3x4 7-1-13 7-1-13 12-11-0 5-9-3 7-1-13 7-1-13 12-11-0 5-9-3 0-8-6 7-1-14 5-1-14 2-0-0 6.00 12 3.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. Job B18802916 Truss T04 Truss Type COMMON Qty 8 Ply 1 CALA 46 CLAY Job Reference (optional) I34850475 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:01 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-RuUZCbkJO7ghc4AUbdRsMPVIjBEM13YBtKZaAvyXBBm Scale = 1:61.3 1 2 3 4 5 6 10 9 8 7 3x6 4x6 5x8 3x6 3x6 2x4 3x6 3x12 2x4 4x6 9-9-13 9-9-13 19-5-12 9-7-15 25-5-0 5-11-4 6-7-2 6-7-2 13-0-7 6-5-5 19-5-12 6-5-5 25-5-0 5-11-4 0-6-8 10-3-6 7-3-12 6.00 12 Plate Offsets (X,Y)-- [1:0-0-7,0-0-15], [1:0-0-15,0-6-8], [1:0-3-8,Edge], [6:0-3-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Job B18802916 Truss T05 Truss Type Common Qty 3 Ply 1 CALA 46 CLAY Job Reference (optional) I34850476 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:01 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-RuUZCbkJO7ghc4AUbdRsMPVIkBET13ZBtKZaAvyXBBm Scale = 1:61.3 1 2 3 4 5 6 7 11 10 9 8 3x6 4x6 5x8 3x6 3x6 2x4 3x6 3x12 2x4 4x6 9-9-13 9-9-13 19-5-12 9-7-15 25-5-0 5-11-4 -0-11-4 0-11-4 6-7-2 6-7-2 13-0-7 6-5-5 19-5-12 6-5-5 25-5-0 5-11-4 0-6-8 10-3-6 7-3-12 6.00 12 Plate Offsets (X,Y)-- [2:0-0-7,0-0-15], [2:0-0-15,0-6-8], [2:0-3-8,Edge], [7:0-3-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 Job B18802916 Truss T06 Truss Type Common Qty 5 Ply 1 CALA 46 CLAY Job Reference (optional) I34850477 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:02 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-v52xQxlx8QoYEElg9Ky5vc2NdbYHmVCL6_J7iLyXBBl Scale = 1:56.0 1 2 3 4 5 6 9 8 7 3x6 4x10 3x4 4x8 3x6 3x6 2x4 3x8 10-7-11 10-7-11 21-5-0 10-9-5 -0-11-4 0-11-4 8-9-13 8-9-13 17-5-12 8-7-15 21-5-0 3-11-4 0-6-8 9-3-6 7-3-12 6.00 12 Plate Offsets (X,Y)-- [2:0-0-7,0-0-15], [2:0-0-15,0-6-8], [2:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Job B18802916 Truss T07 Truss Type COMMON Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850478 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:02 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-v52xQxlx8QoYEElg9Ky5vc2NVbYEmVBL6_J7iLyXBBl Scale = 1:56.0 1 2 3 4 5 8 7 6 3x6 4x10 3x4 4x8 3x6 3x6 2x4 3x8 10-7-11 10-7-11 21-5-0 10-9-5 8-9-13 8-9-13 17-5-12 8-7-15 21-5-0 3-11-4 0-6-8 9-3-6 7-3-12 6.00 12 Plate Offsets (X,Y)-- [1:0-0-7,0-0-15], [1:0-0-15,0-6-8], [1:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 Job B18802916 Truss T14 Truss Type Monopitch Qty 3 Ply 1 CALA 46 CLAY Job Reference (optional) I34850479 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:03 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-NHcKdGlavkwPsOKsj2TKRqai??6SV1dUKe2gFoyXBBk Scale = 1:11.8 1 2 3 4 2x4 2x4 2x4 -0-11-4 0-11-4 1-11-8 1-11-8 0-4-7 1-8-2 1-4-10 0-3-8 1-8-2 8.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.07 0.03 0.00 Job B18802916 Truss T15 Truss Type Monopitch Qty 3 Ply 1 CALA 46 CLAY Job Reference (optional) I34850480 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:03 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-NHcKdGlavkwPsOKsj2TKRqaaz?36V1dUKe2gFoyXBBk Scale = 1:22.8 1 2 3 5 4 3x6 3x4 3x4 3x8 -1-3-4 1-3-4 6-11-8 6-11-8 1-10-0 3-6-14 3-3-6 0-3-8 3-6-14 3.00 12 Plate Offsets (X,Y)-- [4:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R Job B18802916 Truss T16 Truss Type Scissor Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850481 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:04 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-rTAircmCg22FTXv2Hl_Z_17gjPHCEPLdZIoEnEyXBBj Scale = 1:61.4 1 2 3 4 5 8 7 6 4x8 3x6 5x6 8x8 8x8 3x6 8-0-0 8-0-0 16-0-0 8-0-0 -1-3-4 1-3-4 8-0-0 8-0-0 16-0-0 8-0-0 17-3-4 1-3-4 1-9-3 9-9-3 1-9-3 4-5-15 12.00 12 7.00 12 Plate Offsets (X,Y)-- [2:0-1-10,0-1-8], [3:0-4-8,0-2-0], [4:0-1-10,0-1-8], [6:0-0-14,0-1-8], [8:0-0-14,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Job B18802916 Truss T17 Truss Type Scissor Qty 4 Ply 1 CALA 46 CLAY Job Reference (optional) I34850482 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:05 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-Jgk42ynqRLA65hUFqTVoXFgraoalzslnoyXnJgyXBBi Scale = 1:66.0 1 2 3 4 7 6 5 8x8 7x16 MT18HS 4x8 5x8 4x8 8x8 8-0-0 8-0-0 16-0-0 8-0-0 8-0-0 8-0-0 16-0-0 8-0-0 17-3-4 1-3-4 1-9-3 9-9-3 1-9-3 4-5-15 12.00 12 7.00 12 Plate Offsets (X,Y)-- [1:0-1-10,0-1-8], [3:0-1-10,0-1-8], [5:0-8-0,Edge], [7:0-8-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code Job B18802916 Truss T18 Truss Type Roof Special Qty 2 Ply 1 CALA 46 CLAY Job Reference (optional) I34850483 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:05 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-Jgk42ynqRLA65hUFqTVoXFgw?ojazuInoyXnJgyXBBi Scale = 1:60.7 1 2 3 4 7 6 5 5x6 4x6 3x4 3x4 4x8 8x8 6-0-0 6-0-0 14-0-0 8-0-0 6-0-0 6-0-0 14-0-0 8-0-0 15-3-4 1-3-4 2-7-3 8-7-3 9-9-3 0-2-1 1-9-3 0-11-15 4-5-15 12.00 12 7.00 12 Plate Offsets (X,Y)-- [1:0-2-12,0-1-8], [3:0-2-4,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Job B18802916 Truss T19 Truss Type Common Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850484 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:06 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-nsHSGIoSCfIzjr3ROA113SC5nCx2iKMw1cHLr7yXBBh Scale = 1:48.7 1 2 3 4 5 8 7 6 3x4 4x10 3x6 3x8 3x6 2x4 4x8 3x6 10-0-13 10-0-13 20-0-0 9-11-3 5-0-0 5-0-0 12-5-1 7-5-1 20-0-0 7-6-15 5-6-8 8-0-8 0-6-8 6.00 12 Plate Offsets (X,Y)-- [5:0-0-7,0-0-15], [5:0-0-15,0-6-8], [5:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 Job B18802916 Truss T20 Truss Type Common Qty 9 Ply 1 CALA 46 CLAY Job Reference (optional) I34850485 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:07 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-F2rqTeo4zzQqK?edyuYGcglGNcHzRok4FG0uOZyXBBg Scale = 1:52.2 1 2 3 4 5 6 7 8 9 12 11 10 3x6 4x6 3x6 6x6 3x6 3x6 2x4 3x6 2x4 6x6 10-0-10 10-0-10 19-11-6 9-10-13 30-0-0 10-0-10 -0-11-4 0-11-4 7-6-15 7-6-15 15-0-0 7-5-1 22-5-1 7-5-1 30-0-0 7-6-15 30-11-4 0-11-4 0-6-8 8-0-8 0-6-8 6.00 12 Plate Offsets (X,Y)-- [2:0-0-15,0-0-7], [2:0-6-8,0-0-15], [2:0-1-9,0-2-15], [8:0-0-15,0-0-7], [8:0-6-8,0-0-15], [8:0-1-9,0-2-15] LOADING (psf) TCLL Job B18802916 Truss TG03 Truss Type Common Girder Qty 1 Ply 2 CALA 46 CLAY Job Reference (optional) I34850486 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:07 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-F2rqTeo4zzQqK?edyuYGcglBicHVRjS4FG0uOZyXBBg Scale = 1:58.3 1 2 3 4 7 8 9 10 6 11 12 13 5 4x6 8x16 8x16 10x10 8-0-0 8-0-0 16-0-0 8-0-0 -1-3-4 1-3-4 8-0-0 8-0-0 16-0-0 8-0-0 1-4-8 9-4-8 1-4-8 12.00 12 Plate Offsets (X,Y)-- [4:Edge,0-3-8], [5:0-0-0,0-1-12], [7:Edge,0-3-8], [7:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC Job B18802916 Truss TG03 Truss Type Common Girder Qty 1 Ply 2 CALA 46 CLAY Job Reference (optional) I34850486 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:07 2018 Page 2 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-F2rqTeo4zzQqK?edyuYGcglBicHVRjS4FG0uOZyXBBg LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 6=-985(B) 8=-985(B) 9=-985(B) 10=-985(B) 11=-985(B) 12=-985(B) 13=-985(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B18802916 Truss V22 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850487 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:08 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-kFPDg_pikGYhy9DqWb3V8tIYT0oiAGBDUwmRw?yXBBf Scale = 1:49.8 1 2 3 4 5 3x4 8 7 6 4x6 3x4 2x4 2x4 2x4 2x4 2x4 15-8-2 15-8-2 15-8-6 0-0-4 7-10-3 7-10-3 15-8-6 7-10-3 0-0-4 7-10-3 0-0-4 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. Job B18802916 Truss V23 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850488 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:09 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-CRzbuKqKVagYaJo03Iakh5qjjQ8tvj1MjaV?SRyXBBe Scale = 1:43.7 1 2 3 4 5 3x4 8 7 6 4x6 3x4 2x4 2x4 2x4 2x4 2x4 13-8-2 13-8-2 13-8-6 0-0-4 6-10-3 6-10-3 13-8-6 6-10-3 0-0-4 6-10-3 0-0-4 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. Job B18802916 Truss V24 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850489 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:09 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-CRzbuKqKVagYaJo03Iakh5qfZQ8tvkTMjaV?SRyXBBe Scale = 1:37.6 1 2 3 4 5 3x4 8 7 6 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-4 0-0-4 11-8-6 11-8-2 5-10-3 5-10-3 11-8-6 5-10-3 0-0-4 5-10-3 0-0-4 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. Job B18802916 Truss V25 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850490 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:10 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-gdXz5grzGupPBSNCd05zEINsqpR_eBzWxEFY_uyXBBd Scale = 1:32.4 1 2 3 3x8 4 4x6 3x8 2x4 0-0-4 0-0-4 9-8-6 9-8-2 4-10-3 4-10-3 9-8-6 4-10-3 0-0-4 4-10-3 0-0-4 12.00 12 Plate Offsets (X,Y)-- [1:0-5-13,Edge], [3:0-2-9,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH Job B18802916 Truss V26 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850491 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:10 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-gdXz5grzGupPBSNCd05zEINqtpQPeCaWxEFY_uyXBBd Scale = 1:26.2 1 2 3 4 2x4 4x6 2x4 2x4 0-0-4 0-0-4 7-8-6 7-8-2 3-10-3 3-10-3 7-8-6 3-10-3 0-0-4 3-10-3 0-0-4 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P Job B18802916 Truss V27 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850492 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:11 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-8q5LJ0sb1BxGpcxPBjcCmWv2mDiGNfcfAu_6XKyXBBc Scale = 1:20.0 1 2 3 2x4 3x4 2x4 0-0-4 0-0-4 5-8-6 5-8-2 2-10-3 2-10-3 5-8-6 2-10-3 0-0-4 2-10-3 0-0-4 12.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.21 Job B18802916 Truss V28 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850493 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:11 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-8q5LJ0sb1BxGpcxPBjcCmWv4uDnjNfcfAu_6XKyXBBc Scale: 1"=1' 1 2 3 2x4 3x4 2x4 0-0-4 0-0-4 3-8-6 3-8-2 1-10-3 1-10-3 3-8-6 1-10-3 0-0-4 1-10-3 0-0-4 12.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.08 Job B18802916 Truss V29 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850494 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:12 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-c0fjWLsDoV37RmWblR7RJjSGgdAj66spPYkf3myXBBb Scale = 1:7.0 1 2 3 2x4 3x4 2x4 1-8-2 1-8-2 1-8-6 0-0-4 0-10-3 0-10-3 1-8-6 0-10-3 0-0-4 0-10-3 0-0-4 12.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.01 0.02 Job B18802916 Truss V30 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850495 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:12 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-c0fjWLsDoV37RmWblR7RJjSDXd8165ZpPYkf3myXBBb Scale = 1:26.0 1 2 3 5 4 3x6 2x4 2x4 2x4 2x4 9-2-2 9-2-2 0-0-4 4-7-1 6.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.21 0.13 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) Job B18802916 Truss V31 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850496 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:13 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-4CD6khtrZpB_2w5nI8fgrx?PD1VwrXdyeCUCbDyXBBa Scale = 1:41.1 1 2 3 4 5 6 7 3x4 13 12 11 10 9 8 4x6 3x4 2x4 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 24-4-4 24-4-4 12-2-2 12-2-2 24-4-4 12-2-2 0-0-4 6-1-1 0-0-4 6.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 Job B18802916 Truss V32 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850497 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:14 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-YOmUx1uTK6Jrg4gzssAvO8XXMRmMa?k6ssDm7fyXBBZ Scale = 1:34.3 1 2 3 4 5 3x8 8 7 6 4x6 3x6 2x4 2x4 2x4 5x6 2x4 20-4-4 20-4-4 10-2-2 10-2-2 20-4-4 10-2-2 0-0-4 5-1-1 0-0-4 6.00 12 Plate Offsets (X,Y)-- [6:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC Job B18802916 Truss V33 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850498 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:14 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-YOmUx1uTK6Jrg4gzssAvO8XarRqua?96ssDm7fyXBBZ Scale = 1:27.8 1 2 3 4 5 3x4 9 8 7 6 4x6 3x4 2x4 2x4 3x6 2x4 2x4 2x4 16-4-4 16-4-4 8-2-2 8-2-2 16-4-4 8-2-2 0-0-4 4-1-1 0-0-4 6.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC Job B18802916 Truss V34 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850499 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:15 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-0bKs9Nv54QRiIEFAQZh8xM4g_q7RJSCF5WzJg5yXBBY Scale = 1:21.6 1 2 3 4 3x12 4x8 2x4 3x12 12-4-4 12-4-4 6-2-2 6-2-2 12-4-4 6-2-2 0-0-4 3-1-1 0-0-4 6.00 12 Plate Offsets (X,Y)-- [1:0-9-11,Edge], [3:0-3-3,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.45 0.34 Job B18802916 Truss V35 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850500 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:15 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-0bKs9Nv54QRiIEFAQZh8xM4hQqAdJTqF5WzJg5yXBBY Scale = 1:15.7 1 2 3 4 2x4 4x6 2x4 2x4 8-4-4 8-4-4 4-2-2 4-2-2 8-4-4 4-2-2 0-0-4 2-1-1 0-0-4 6.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.42 0.14 0.05 Job B18802916 Truss V36 Truss Type Valley Qty 1 Ply 1 CALA 46 CLAY Job Reference (optional) I34850501 Builders First Source, mooresville,in 8.220 s Sep 24 2018 MiTek Industries, Inc. Wed Oct 3 08:01:16 2018 Page 1 ID:wnwdDqo9FWZSvR?mVjmvEmzUs4h-VnuEMjvjrkZZvNqM_HCNTZdxXEVa2wrOKAisCYyXBBX Scale = 1:8.3 1 2 3 2x4 3x4 2x4 4-4-4 4-4-4 2-2-2 2-2-2 4-4-4 2-2-2 0-0-4 1-1-1 0-0-4 6.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.08 0.22 0.00 edge of truss. / 16 " from outside 1 0 - PRODUCT CODE APPROVALS JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. W4-6 W3-6 W3-7 W2-7 W1-7 C1-8 C7-8 C6-7 C5-6 C4-5 C3-4 C1-2 C2-3 TOP CHORD TOP CHORD 8 7 6 5 4 1 2 3 BOTTOM CHORDS TOP CHORDS BEARING LATERAL BRACING LOCATION Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. The first dimension is the plate width measured perpendicular to slots. Second dimension is the length parallel to slots. 4 x 4 PLATE SIZE This symbol indicates the required direction of slots in connector plates. / 16 " 1 For 4 x 2 orientation, locate plates 0- Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 1 " / 4 3 PLATE LOCATION AND ORIENTATION Symbols Numbering System 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. Failure to Follow Could Cause Property Damage or Personal Injury General Safety Notes * Plate location details available in MiTek 20/20 software or upon request. Industry Standards: 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) © 2012 MiTek® All Rights Reserved MiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015 WEBS edge of truss. / 16 " from outside 1 0 - ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. W4-6 W3-6 W3-7 W2-7 W1-7 C1-8 C7-8 C6-7 C5-6 C4-5 C3-4 C1-2 C2-3 TOP CHORD TOP CHORD 8 7 6 5 4 1 2 3 BOTTOM CHORDS TOP CHORDS BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. 4 x 4 PLATE SIZE This symbol indicates the required direction of slots in connector plates. / 16 " 1 For 4 x 2 orientation, locate plates 0- 1 " / 4 3 PLATE LOCATION AND ORIENTATION Symbols Numbering System General Safety Notes * Plate location details available in MiTek 20/20 software or upon request. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 dimensions shown in ft-in-sixteenths WEBS Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-4-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=124/4-4-4, 3=124/4-4-4 Max Horz 1=8(LC 5) Max Uplift 1=-6(LC 6), 3=-6(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=144/8-4-4, 3=144/8-4-4, 4=279/8-4-4 Max Horz 1=-17(LC 4) Max Uplift 1=-20(LC 6), 3=-23(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=198/12-4-4, 3=198/12-4-4, 4=492/12-4-4 Max Horz 1=-27(LC 4) Max Uplift 1=-21(LC 6), 3=-25(LC 7), 4=-3(LC 6) Max Grav 1=202(LC 10), 3=202(LC 11), 4=492(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-296/103 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 WB Matrix-SH 0.16 0.17 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 16-4-4. (lb) - Max Horz 1=37(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 8=263(LC 1), 9=358(LC 10), 6=357(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-265/131, 4-6=-268/132 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9, 6. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 BC WB Matrix-SH 0.38 0.40 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 56 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-6: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 20-4-4. (lb) - Max Horz 1=-47(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=482(LC 10), 6=477(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-342/163, 4-6=-340/160 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 8, 6. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.15 0.09 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 72 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 24-4-4. (lb) - Max Horz 1=-56(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 12, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 11=271(LC 1), 12=336(LC 10), 13=334(LC 1), 9=336(LC 11), 8=334(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-12=-260/130, 5-9=-260/130 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 9, 8. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=146/9-2-2, 4=111/9-2-2, 5=415/9-2-2 Max Horz 1=132(LC 5) Max Uplift 4=-13(LC 5), 5=-76(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-298/180 NOTES- (6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 3 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-8-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=40/1-7-14, 3=40/1-7-14 Max Horz 1=12(LC 5) Max Uplift 1=-1(LC 7), 3=-1(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 0.20 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-8-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=120/3-7-14, 3=120/3-7-14 Max Horz 1=35(LC 5) Max Uplift 1=-3(LC 7), 3=-3(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 0.55 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=200/5-7-14, 3=200/5-7-14 Max Horz 1=58(LC 5) Max Uplift 1=-5(LC 7), 3=-5(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 0.41 0.27 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=167/7-7-14, 3=167/7-7-14, 4=225/7-7-14 Max Horz 1=-81(LC 4) Max Uplift 1=-28(LC 7), 3=-28(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 0.29 0.23 0.09 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=193/9-7-14, 3=193/9-7-14, 4=334/9-7-14 Max Horz 1=105(LC 5) Max Uplift 1=-14(LC 7), 3=-14(LC 7), 4=-3(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 TC BC WB Matrix-SH 0.38 0.10 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 36 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 11-7-14. (lb) - Max Horz 1=-128(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-147(LC 6), 6=-147(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=296(LC 10), 6=296(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=147, 6=147. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 TC BC WB Matrix-SH 0.18 0.10 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 47 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 13-7-14. (lb) - Max Horz 1=-151(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-153(LC 6), 6=-153(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=312(LC 10), 6=312(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=153, 6=153. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 TC BC WB Matrix-SH 0.15 0.09 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 56 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 15-7-14. (lb) - Max Horz 1=-174(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-172(LC 6), 6=-172(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=355(LC 10), 6=355(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-261/208, 4-6=-261/208 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=172, 6=172. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 BC WB Matrix-SH 0.92 0.79 0.52 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.11 -0.28 0.01 (loc) 6-7 6-7 5 l/defl >999 >665 n/a L/d 240 180 n/a PLATES MT20 Weight: 185 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF 2100F 1.8E *Except* 3-6: 2x4 SPF No.2, 2-6,4-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 7=4141/0-3-8, 5=4096/0-3-8 Max Horz 7=241(LC 4) Max Uplift 7=-316(LC 5), 5=-285(LC 5) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3505/319, 3-4=-3491/312, 2-7=-2867/265, 4-5=-2774/229 BOT CHORD 6-7=-421/1112, 5-6=-186/1016 WEBS 3-6=-267/4263, 2-6=-237/1406, 4-6=-193/1420 NOTES- (9-10) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 7=316, 5=285. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 985 lb down and 75 lb up at 2-0-12, 985 lb down and 75 lb up at 4-0-12, 985 lb down and 75 lb up at 6-0-12, 985 lb down and 75 lb up at 8-0-12, 985 lb down and 75 lb up at 10-0-12, and 985 lb down and 75 lb up at 12-0-12, and 985 lb down and 75 lb up at 14-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.62 0.83 0.25 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.23 -0.66 0.09 (loc) 2-12 2-12 8 l/defl >999 >542 n/a L/d 240 180 n/a PLATES MT20 Weight: 105 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 7-10,3-12: 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 2=1253/0-3-8, 8=1253/0-3-8 Max Horz 2=-79(LC 7) Max Uplift 2=-92(LC 6), 8=-92(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2018/298, 3-5=-1793/319, 5-7=-1793/319, 7-8=-2018/298 BOT CHORD 2-12=-165/1718, 10-12=-12/1148, 8-10=-165/1718 WEBS 5-10=-71/680, 7-10=-419/212, 5-12=-71/680, 3-12=-419/212 NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.61 0.81 0.26 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.23 -0.57 0.03 (loc) 6-8 6-8 5 l/defl >999 >416 n/a L/d 240 180 n/a PLATES MT20 Weight: 79 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-6,1-8: 2x4 SPF-S Stud WEDGE Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-8 REACTIONS. (lb/size) 5=788/0-3-8, 8=788/0-3-8 Max Horz 8=-191(LC 4) Max Uplift 5=-44(LC 7), 8=-46(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-982/211, 4-5=-1201/186 BOT CHORD 6-8=0/374, 5-6=-80/1001 WEBS 2-6=-78/738, 4-6=-438/222, 2-8=-673/65 NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 8. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.61 0.31 0.25 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.13 -0.34 0.05 (loc) 5-6 5-6 5 l/defl >999 >476 n/a L/d 240 180 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-5: 2x6 SPF No.2, 3-6: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 7=540/Mechanical, 5=640/0-3-8 Max Horz 7=-267(LC 4) Max Uplift 7=-24(LC 7), 5=-61(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-689/0, 2-3=-757/44, 1-7=-511/38, 3-5=-688/185 BOT CHORD 6-7=-232/331, 5-6=-133/304 WEBS 2-6=0/487, 1-6=0/365, 3-6=-138/485 NOTES- (8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.90 0.88 0.34 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.37 -0.79 0.94 (loc) 6 6 5 l/defl >498 >237 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 60 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x6 SPF No.2 *Except* 2-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 7=617/0-3-8, 5=716/0-3-8 Max Horz 7=-260(LC 4) Max Uplift 7=-26(LC 7), 5=-54(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-885/0, 2-3=-900/66, 1-7=-771/23, 3-5=-881/32 BOT CHORD 6-7=-89/563, 5-6=-68/569 WEBS 2-6=0/667 NOTES- (8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 7, 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.90 0.64 0.35 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.39 -0.62 0.74 (loc) 7 7 6 l/defl >475 >300 n/a L/d 240 180 n/a PLATES MT20 Weight: 62 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x6 SPF No.2 *Except* 3-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=712/0-3-8, 6=712/0-3-8 Max Horz 8=-242(LC 4) Max Uplift 8=-56(LC 6), 6=-56(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-898/0, 3-4=-898/68, 2-8=-881/70, 4-6=-881/35 BOT CHORD 7-8=-90/570, 6-7=-69/570 WEBS 3-7=0/682 NOTES- (7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Bearing at joint(s) 8, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 0.58 0.25 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.19 0.00 (loc) 4-5 4-5 4 l/defl >999 >426 n/a L/d 240 180 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=361/0-3-8, 4=258/0-1-8 Max Horz 5=105(LC 5) Max Uplift 5=-65(LC 4), 4=-31(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-304/172 NOTES- (7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 2 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 2=145/0-3-8, 4=56/0-1-8 Max Horz 2=45(LC 5) Max Uplift 2=-42(LC 6), 4=-6(LC 5) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.82 0.93 0.33 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.31 -0.76 0.03 (loc) 6-8 6-8 6 l/defl >828 >336 n/a L/d 240 180 n/a PLATES MT20 Weight: 87 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-8,5-6: 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 4-6 REACTIONS. (lb/size) 1=845/0-3-8, 6=845/0-3-8 Max Horz 1=241(LC 5) Max Uplift 1=-44(LC 6), 6=-65(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1270/186, 2-4=-1097/257 BOT CHORD 1-8=-123/1054, 6-8=-60/295 WEBS 2-8=-516/262, 4-8=-144/936, 4-6=-734/85 NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.81 0.93 0.33 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.31 -0.76 0.03 (loc) 7-9 7-9 7 l/defl >828 >335 n/a L/d 240 180 n/a PLATES MT20 Weight: 88 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-9,6-7: 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-5 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 5-7 REACTIONS. (lb/size) 2=912/0-3-8, 7=843/0-3-8 Max Horz 2=245(LC 5) Max Uplift 2=-79(LC 6), 7=-64(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1289/182, 3-5=-1091/253 BOT CHORD 2-9=-119/1048, 7-9=-60/294 WEBS 3-9=-513/260, 5-9=-139/930, 5-7=-732/83 NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 7. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.44 0.77 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.52 0.05 (loc) 2-11 2-11 8 l/defl >999 >583 n/a L/d 240 180 n/a PLATES MT20 Weight: 113 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-11,5-11,7-8: 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-9, 7-8 REACTIONS. (lb/size) 2=1071/0-3-8, 8=1004/0-3-8 Max Horz 2=254(LC 5) Max Uplift 2=-90(LC 6), 8=-62(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1662/235, 3-5=-1406/222, 5-6=-621/194, 6-7=-599/195, 7-8=-962/166 BOT CHORD 2-11=-189/1407, 9-11=-72/959 WEBS 3-11=-332/174, 5-11=-5/562, 5-9=-715/201, 7-9=-25/730 NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.44 0.78 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.52 0.05 (loc) 1-10 1-10 7 l/defl >999 >574 n/a L/d 240 180 n/a PLATES MT20 Weight: 112 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-10,4-10,6-7: 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-8, 6-7 REACTIONS. (lb/size) 1=1005/0-3-8, 7=1005/0-3-8 Max Horz 1=251(LC 5) Max Uplift 1=-56(LC 6), 7=-63(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1670/241, 2-4=-1412/227, 4-5=-621/195, 5-6=-600/196, 6-7=-963/167 BOT CHORD 1-10=-195/1416, 8-10=-74/961 WEBS 2-10=-336/177, 4-10=-9/564, 4-8=-718/204, 6-8=-26/731 NOTES- (6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 TC BC WB Matrix-SH 0.44 0.63 0.75 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.22 0.08 (loc) 5 5-6 4 l/defl >999 >681 n/a L/d 240 180 n/a PLATES MT20 Weight: 44 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 1-6: 2x6 SP 2400F 2.0E BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=502/0-3-8, 6=502/0-3-8 Max Horz 6=187(LC 5) Max Uplift 4=-74(LC 6), 6=-13(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1070/196, 1-6=-658/161 BOT CHORD 5-6=-214/911, 4-5=-195/843 WEBS 2-5=0/421, 2-4=-883/279 NOTES- (6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 6. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 TC BC WB Matrix-SH 0.42 0.59 0.80 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.09 -0.25 0.08 (loc) 5-6 5-6 4 l/defl >999 >611 n/a L/d 240 180 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 1-6: 2x6 SP 2400F 2.0E BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=514/0-3-8, 6=514/0-7-4 Max Horz 6=189(LC 5) Max Uplift 4=-75(LC 6), 6=-13(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1134/203, 1-6=-689/166 BOT CHORD 5-6=-223/972, 4-5=-203/897 WEBS 2-5=0/445, 2-4=-942/287 NOTES- (6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 6. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.04 -0.11 -0.00 (loc) 3-4 3-4 3 l/defl >999 >626 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=227/0-3-8, 3=227/0-1-8 Max Horz 4=136(LC 5) Max Uplift 3=-43(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-MSH 0.33 0.51 0.79 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.17 0.05 (loc) 7-12 7-12 6 l/defl >999 >915 n/a L/d 240 180 n/a PLATES MT20 Weight: 46 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x3 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 2=595/0-7-4, 6=508/0-1-8 Max Horz 2=191(LC 5) Max Uplift 2=-46(LC 6), 6=-73(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1102/194 BOT CHORD 2-7=-209/963, 6-7=-188/881 WEBS 4-7=0/439, 4-6=-926/271 NOTES- (7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 2, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.85 0.97 0.89 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.39 -0.99 -0.67 (loc) 8-10 8-10 12 l/defl >705 >277 n/a L/d 240 180 n/a PLATES MT20 Weight: 124 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-8,1-10: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-9 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 4-7, 2-10 REACTIONS. (lb/size) 10=918/0-5-8, 12=903/0-3-8 Max Horz 10=361(LC 5) Max Uplift 12=-177(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-822/77, 7-11=-129/734, 5-11=-129/734 BOT CHORD 8-10=-166/763, 7-8=-107/486 WEBS 4-8=-76/558, 4-7=-775/254, 2-10=-885/0, 5-12=-905/213 NOTES- (6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 12 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 12=177. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.40 0.61 0.40 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.41 -0.10 (loc) 9-10 9-10 12 l/defl >999 >532 n/a L/d 240 180 n/a PLATES MT20 Weight: 125 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 1-10: 2x4 SPF-S Stud OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-9, 4-7, 2-10, 5-12 REACTIONS. (lb/size) 10=735/0-5-8, 12=714/0-1-8 Max Horz 10=314(LC 6) Max Uplift 12=-206(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-490/38, 7-11=-183/577, 5-11=-183/577 BOT CHORD 9-10=-192/393, 7-9=-71/289 WEBS 2-9=-81/258, 4-9=-126/366, 4-7=-555/268, 2-10=-613/0, 5-12=-714/254 NOTES- (7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 12 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 12. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 12=206. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 3x8 17-9-13 30-0-0 30-0-0 -0-11-4 0-11-4 15-0-0 15-0-0 30-0-0 15-0-0 30-11-4 0-11-4 0-6-8 8-0-8 0-6-8 6.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-13], [2:0-2-9,Edge], [9:0-3-0,0-3-0], [17:0-3-0,0-3-0], [24:Edge,0-0-13], [24:0-2-9,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.06 0.02 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.01 (loc) 25 25 24 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 158 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 30-0-0. (lb) - Max Horz 2=-79(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 2, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26 Max Grav All reactions 250 lb or less at joint(s) 2, 36, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 24 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 8-0-0 8-0-0 16-0-0 8-0-0 -1-3-4 1-3-4 8-0-0 8-0-0 16-0-0 8-0-0 17-3-4 1-3-4 1-9-3 9-9-3 1-9-3 4-5-15 12.00 12 7.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.35 0.17 0.26 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.01 (loc) 15 15 16 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 89 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 16-0-0. (lb) - Max Horz 28=-243(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 23, 24, 25, 26, 21, 20, 19, 18 except 28=-348(LC 4), 16=-190(LC 5), 27=-242(LC 5), 17=-226(LC 4) Max Grav All reactions 250 lb or less at joint(s) 16, 23, 24, 25, 26, 21, 20, 19, 18, 17 except 28=315(LC 5), 22=493(LC 7), 27=255(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-6=-19/260, 6-7=-19/327, 7-8=-23/353, 8-9=-23/353, 9-10=-19/327, 10-11=-19/260 WEBS 8-22=-440/0 NOTES- (11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 24, 25, 26, 21, 20, 19, 18 except (jt=lb) 28=348, 16=190, 27=242, 17=226. 9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 22, 23, 24, 25, 26, 27, 21, 20, 19, 18, 17. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.24 0.12 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.05 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=285/0-3-8, 4=174/0-1-8 Max Horz 5=89(LC 5) Max Uplift 5=-62(LC 4), 4=-22(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 1-4-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=58/1-11-8, 2=143/1-11-8 Max Horz 2=45(LC 5) Max Uplift 4=-6(LC 5), 2=-40(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=58/1-11-8, 2=143/1-11-8 Max Horz 2=45(LC 5) Max Uplift 4=-6(LC 5), 2=-40(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 16-0-0 16-0-0 -1-3-4 1-3-4 8-0-0 8-0-0 16-0-0 8-0-0 17-3-4 1-3-4 1-4-8 9-4-8 1-4-8 12.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.27 0.13 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 15 15 16 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 108 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 8-22: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 8-22 REACTIONS. All bearings 16-0-0. (lb) - Max Horz 28=-227(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 23, 24, 25, 26, 21, 20, 19, 18 except 28=-202(LC 4), 16=-180(LC 5), 27=-185(LC 5), 17=-170(LC 4) Max Grav All reactions 250 lb or less at joint(s) 28, 16, 23, 24, 25, 26, 27, 21, 20, 19, 18, 17 except 22=325(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-18/270, 7-8=-20/296, 8-9=-20/296, 9-10=-18/270 WEBS 8-22=-358/0 NOTES- (10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 24, 25, 26, 21, 20, 19, 18 except (jt=lb) 28=202, 16=180, 27=185, 17=170. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=64/2-4-10, 3=64/2-4-10 Max Horz 1=26(LC 5) Max Uplift 1=-2(LC 6), 3=-9(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.27 0.13 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 5-11-8. (lb) - Max Horz 12=136(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 12, 7, 8, 9, 10 except 11=-308(LC 5) Max Grav All reactions 250 lb or less at joint(s) 7, 8, 9, 10, 11 except 12=344(LC 5) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 7, 8, 9, 10 except (jt=lb) 11=308. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.27 0.13 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 1 1 12 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 13-2-12. (lb) - Max Horz 2=217(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 12, 13, 14, 15, 16, 17, 18, 19, 20 Max Grav All reactions 250 lb or less at joint(s) 12, 2, 13, 14, 15, 16, 17, 18, 19, 20 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 14, 15, 16, 17, 18, 19, 20. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 5x6 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 25-11-15 23-3-0 23-3-0 23-3-0 23-3-0 2-10-2 14-5-10 6.00 12 Plate Offsets (X,Y)-- [11:0-3-0,0-3-0], [19:0-4-8,Edge], [30:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.53 0.33 0.41 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 20 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 238 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-11: 2x4 SP 2400F 2.0E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 *Except* 10-30,9-31,8-32,7-33,6-34,5-35,4-36,3-37,2-38: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 20-21. WEBS 1 Row at midpt 19-21, 18-22, 17-23, 16-24, 15-25, 14-26, 13-27, 12-28, 11-29, 10-30 REACTIONS. All bearings 23-3-0. (lb) - Max Horz 38=435(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 38, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35 except 20=-119(LC 5), 37=-835(LC 5), 21=-155(LC 6) Max Grav All reactions 250 lb or less at joint(s) 20, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 21 except 38=839(LC 5) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-42/277, 2-3=-568/44, 3-4=-273/26, 4-5=-302/36, 5-6=-289/44, 6-7=-275/51, 7-8=-261/58, 1-38=-97/980 WEBS 3-37=-94/643, 2-38=-1641/148 NOTES- (9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 38, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35 except (jt=lb) 20=119, 37=835, 21=155. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 20-9-5 18-7-0 18-7-0 18-7-0 18-7-0 5-2-2 14-5-10 6.00 12 Plate Offsets (X,Y)-- [16:0-4-8,Edge], [23:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.75 0.73 0.26 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 17 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 218 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-9: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 23-32: 2x4 SP 2400F 2.0E WEBS 2x4 SPF No.2 *Except* 1-32: 2x6 SPF No.2 OTHERS 2x4 SPF No.2 *Except* 6-27,5-28,4-29,3-30,2-31: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 16-18, 15-19, 14-20, 13-21, 12-22, 11-23, 10-24, 8-25, 7-26, 6-27 REACTIONS. All bearings 18-7-0. (lb) - Max Horz 32=428(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 21, 23, 25, 26, 27, 28, 29, 30 except 32=-369(LC 4), 17=-174(LC 5), 31=-1790(LC 5), 18=-161(LC 6) Max Grav All reactions 250 lb or less at joint(s) 17, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 18 except 32=1745(LC 5), 31=413(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-574/103, 2-3=-268/49, 1-32=-783/154 WEBS 2-31=-137/672 NOTES- (9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 21, 23, 25, 26, 27, 28, 29, 30 except (jt=lb) 32=369, 17=174, 31=1790, 18=161. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 3x8 20-7-1 4-4-13 21-5-0 21-5-0 -0-11-4 0-11-4 17-5-12 17-5-12 21-5-0 3-11-4 0-6-8 9-3-6 7-3-12 6.00 12 Plate Offsets (X,Y)-- [2:Edge,0-0-13], [2:0-2-9,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.31 0.13 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 1 1 20 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 140 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 16-23,15-24,17-22: 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 16-23, 15-24, 17-22 REACTIONS. All bearings 21-5-0. (lb) - Max Horz 2=245(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 20, 23, 24, 25, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 21, 2 Max Grav All reactions 250 lb or less at joint(s) 20, 23, 24, 25, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 22, 21, 2 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 23, 24, 25, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 21, 2. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5-3-12 2-2-13 22-9-15 2-11-0 2-11-0 2-11-0 9-9-13 6-10-13 19-5-12 9-7-15 25-5-0 5-11-4 -0-11-4 0-11-4 6-7-2 6-7-2 13-0-7 6-5-5 19-5-12 6-5-5 21-5-12 2-0-0 25-5-0 3-11-4 0-6-8 10-3-6 7-3-12 6.00 12 Plate Offsets (X,Y)-- [2:0-0-7,0-0-15], [2:0-0-15,0-6-8], [2:0-3-8,Edge], [4:0-3-0,0-3-0], [16:0-2-4,0-2-4], [16:0-2-2,0-0-6] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.51 0.79 0.44 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.51 0.05 (loc) 10-12 10-12 9 l/defl >999 >589 n/a L/d 240 180 n/a PLATES MT20 Weight: 151 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 5-10,6-10,7-9: 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-10, 7-9 JOINTS 1 Brace at Jt(s): 15 REACTIONS. (lb/size) 2=1071/0-3-8, 9=1004/0-3-8 Max Horz 2=254(LC 5) Max Uplift 2=-90(LC 6), 9=-62(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1870/201, 3-5=-1611/185, 5-6=-993/160, 6-7=-961/185 BOT CHORD 2-13=-160/1562, 12-13=-214/1270, 10-12=-81/873, 9-10=-34/395 WEBS 3-14=-289/181, 12-14=-292/180, 12-15=-19/470, 5-15=-16/453, 5-16=-656/208, 10-16=-674/212, 10-17=-58/658, 6-17=-57/651, 7-9=-951/51, 13-14=0/405, 14-15=0/387, 15-16=0/419, 16-17=0/496, 7-17=0/533 NOTES- (8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 9. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 3x8 21-9-5 6-7-11 25-5-0 25-5-0 19-5-12 19-5-12 25-5-0 5-11-4 0-6-8 10-3-6 7-3-12 6.00 12 Plate Offsets (X,Y)-- [1:0-2-9,Edge], [1:0-0-0,0-0-13], [7:0-3-0,0-3-0], [29:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.30 0.12 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 21 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 182 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 15-25,14-26,13-27,16-24,17-23: 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 15-25, 14-26, 13-27, 16-24, 17-23 REACTIONS. All bearings 25-5-0. (lb) - Max Horz 1=251(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 21, 29, 25, 26, 27, 28, 30, 31, 32, 33, 34, 35, 36, 37, 38, 24, 23, 22, 1 Max Grav All reactions 250 lb or less at joint(s) 21, 29, 25, 26, 27, 28, 30, 31, 32, 33, 34, 35, 36, 37, 38, 24, 23, 22, 1 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 21, 29, 25, 26, 27, 28, 30, 31, 32, 33, 34, 35, 36, 37, 38, 24, 23, 22, 1. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 3,2018