Loading...
HomeMy WebLinkAboutTSI PATEL AS-DESIGNEDBUILDING FILE REPORT File Name: PATEL_MCKENZIE_CODE.blg Date: August 13, 2018 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Property/Builder: Organization Building Name: PATEL Org. Name: TSI ENERGY SOLUTIONS Owner's Name: HOMES BY MCKENZIE, INC Address: P.O. BOX 705 Property Address: 11151 HINTOCKS CIR City, St, Zip: CARMEL, IN 46082 City, St, Zip: CARMEL (AS DESIGNED), IN 46032 Phone No: 317-846-4655 Phone No: Website: www.tsienergysolutions.com Builder's Name: HOMES BY McKENZIE, INC Rater's Name: MICHAEL HILL Phone No: 317-574-8806 Rater's Email: mhill@tsienergysolutions.com Email Address:jmckenzie1@johnmckenziecollection.com Rater's ID: 9479271 Model: PATEL RESIDENCE Provider ID: 1998-053 Development: PATEL Sample Set ID: 0000 Permit Date/Number: Rating Date: 08/13/2018 Rating Type: Projected Rating Reason: New Home Rating No.: Registry ID: Verifier's Name: Verifier's ID: Verifier's Name:: Verifier's ID: Verifier's Name:: Verifier's ID: Verifier's Name: Verifier's ID: General Building Information Area of Cond. Space(sq ft): 10574 Volume of Cond. Space: 119917 Year Built: 2018 Housing Type: Single-family detached Level Type(Apartments Only): None Floors on or Above-Grade: 3+ Number of Bedrooms: 6 Foundation Type: More than one type Enclosed Crawl Space Type: N/A Number of Stories Including Conditioned Basement: 3 Thermal Boundary Location: REM Default BUILDING FILE REPORT PATEL Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Foundation Wall Info:1 2 3 Name COND/AMB FIN COND/AMB UNFIN COND/GAR FIN Library Type R-11 Finished R-10 Draped, 4' R-11 Finished Length(ft) 43.0 189.0 12.0 Total Height(ft) 10.0 10.0 10.0 Depth Below Grade(ft) 9.0 9.0 9.0 Height Above Grade(ft) 1.0 1.0 1.0 Location Cond->ambient/grnd Cond->ambient/grnd Cond->ambient/grnd Uo Value (wall, airfilm, & soil) 0.056 0.074 0.056 Uo Value (wall assembly only) 0.099 0.941 0.099 Foundation Wall Info:4 Name COND/GAR UNFIN Library Type R-10 Draped, 4' Length(ft) 22.0 Total Height(ft) 10.0 Depth Below Grade(ft) 9.0 Height Above Grade(ft) 1.0 Location Cond->ambient/grnd Uo Value (wall, airfilm, & soil) 0.074 Uo Value (wall assembly only) 0.941 Foundation Wall: R-11 Finished Type: Solid concrete or stone Thickness(in): 8.0 Studs: Wood, 2x4, 16" o.c. Interior Insulation: Continuous R-Value: 0.5 Frame Cavity R-Value: 11.0 Cavity Insulation Grade: 1 Ins top: 0.0 ft from top of wall Ins Bottom: 0.0 ft from bottom of wall Exterior Insulation: R-Value: 0.0 Ins top: 0.0 ft from top of wall Ins bottom: 0.0 ft below grade Note: BUILDING FILE REPORT PATEL Page 3 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Foundation Wall: R-10 Draped, 4' Type: Solid concrete or stone Thickness(in): 8.0 Studs: None Interior Insulation: Continuous R-Value: 10.0 Frame Cavity R-Value: 0.0 Cavity Insulation Grade: 1 Ins top: 0.0 ft from top of wall Ins Bottom: 4.0 ft from top of wall Exterior Insulation: R-Value: 0.0 Ins top: 0.0 ft above grade Ins bottom: 0.0 ft from bottom of wall Note: Slab Floor Info:1 2 Name BSMT SLAB WO Library Type Uninsulated R-10, 2'down, 2' in Area(sq ft) 3987 403 Depth Below Grade(ft) 9.0 0.0 Full Perimeter(ft) 374 209 Exposed Perimeter(ft) 374 209 On-Grade Perimeter(ft) 0 96 Slab Floor: Uninsulated Slab Covering None Perimeter Insulation (R-Value): 0.0 Perimeter Insulation Depth (ft): 0.0 Under-Slab Insulation (R-Value): 0.0 Under-Slab Insulation Width (ft): 0.0 Slab Insulation Grade: 1 Radiant Slab: No Note: BUILDING FILE REPORT PATEL Page 4 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Slab Floor: R-10, 2'down, 2' in Slab Covering Carpet Perimeter Insulation (R-Value): 10.0 Perimeter Insulation Depth (ft): 2.0 Under-Slab Insulation (R-Value): 10.0 Under-Slab Insulation Width (ft): 2.0 Slab Insulation Grade: 1 Radiant Slab: No Note: Floor Info:1 Name OVER AMB Library Type GR-1 R-30 Area (sq ft) 19 Location Btwn cond & ambient Uo Value 0.035 BUILDING FILE REPORT PATEL Page 5 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Floor: GR-1 R-30 Information From Quick Fill Screen: Continous Insulation R-Value 0.0 Cavity Insulation R-Value 30.0 Cavity Insulation Thickness (in.) 9.5 Cavity Insulation Grade 1.0 Joist Size (w x h, in) 1.5 x 9.5 Joist Spacing (in oc) 16.0 Framing Factor - (default)0.1300 Floor Covering CARPET Note: Layers Paths Cavity Framing Grade Inside Air Film 0.920 0.920 0.920 Floor covering 1.230 1.230 1.230 Subfloor 0.820 0.820 0.820 Cavity ins 30.000 0.000 0.000 Continuous ins 0.000 0.000 0.000 Framing 0.000 11.875 0.000 0.000 0.000 0.000 Outside Air Film 0.455 0.455 0.455 Total R-Value 33.425 15.300 3.425 U-Value 0.030 0.065 0.292 Relative Area 0.870 0.130 0.000 UA 0.026 0.008 0.000 Total Component UA: 0.035 Total Component Area: 1.0 Component Uo: 0.035 BUILDING FILE REPORT PATEL Page 6 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Rim and Band Joist:1 2 3 Name COND/AMB COND/GAR COND/ATTIC Area(sq ft) 362.0 34.0 167.0 Continuous Ins 0.5 0.5 0.5 Framed Cavity Ins 15.0 15.0 15.0 Cavity Ins Thk(in) 3.5 3.5 3.5 Joist Spacing 16.0 16.0 16.0 Insulation Grade 1 1 1 Location Cond -> ambient Cond -> garage Cond -> attic Uo Value 0.061 0.061 0.061 Above-Grade Wall:1 2 3 Name COND/AMB COND/GAR COND/ATTIC Library Type G1 R-15 BATT, OSB G1 R-15 Gar Walls G1 R-15 BATT, OSB Gross Area(sq ft) 5056.00 408.00 1352.00 Exterior Color Medium Dark Dark Location Cond -> ambient Cond -> garage Cond -> garage Uo Value 0.076 0.076 0.076 BUILDING FILE REPORT PATEL Page 7 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Above-Grade Wall: G1 R-15 BATT, OSB Information From Quick Fill Screen: Standard Wood Frame Continuous Insulation (R-Value) 0.5 Frame Cavity Insulation (R-Value) 15.0 Frame Cavity Insulation Thickness (in) 3.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in)1.5 x 3.5 Stud Spacing (in o.c.) 16.0 Framing Factor - (default)0.2300 Gypsum Thickness (in) 0.5 Note: Layers Paths Cavity Framing Grade Inside Air Film 0.680 0.680 0.680 Gyp board 0.450 0.450 0.450 Air Gap/Frm 0.000 0.000 0.000 Cavity ins/Frm 15.000 4.375 1.030 Continuous ins 0.500 0.500 0.500 Ext Finish 0.940 0.940 0.940 0.000 0.000 0.000 Outside Air Film 0.170 0.170 0.170 Total R-Value 17.740 7.115 3.770 U-Value 0.056 0.141 0.265 Relative Area 0.770 0.230 0.000 UA 0.043 0.032 0.000 Total Component UA: 0.076 Total Component Area: 1.0 Component Uo: 0.076 BUILDING FILE REPORT PATEL Page 8 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Above-Grade Wall: G1 R-15 Gar Walls Information From Quick Fill Screen: Standard Wood Frame Continuous Insulation (R-Value) 0.0 Frame Cavity Insulation (R-Value) 15.0 Frame Cavity Insulation Thickness (in) 3.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in)1.5 x 3.5 Stud Spacing (in o.c.) 16.0 Framing Factor - (default)0.2300 Gypsum Thickness (in) 1.0 Note: Layers Paths Cavity Framing Grade Inside Air Film 0.680 0.680 0.680 Gyp board 0.900 0.900 0.900 Air Gap/Frm 0.000 0.000 0.000 Cavity ins/Frm 15.000 4.375 1.030 Continuous ins 0.000 0.000 0.000 Ext Finish 0.940 0.940 0.940 0.000 0.000 0.000 Outside Air Film 0.170 0.170 0.170 Total R-Value 17.690 7.065 3.720 U-Value 0.057 0.142 0.269 Relative Area 0.770 0.230 0.000 UA 0.044 0.033 0.000 Total Component UA: 0.076 Total Component Area: 1.0 Component Uo: 0.076 BUILDING FILE REPORT PATEL Page 9 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Window Information:1 2 3 Name FRONT GD GD Library Type U-.29, SHGC-.27 U-.29, SHGC-.27 U-.29, SHGC-.27 U-Value 0.290 0.290 0.290 SHGC 0.270 0.270 0.270 Area(sq ft) 417.00 48.00 60.00 Orientation South South South Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 1 AGWall 1 AGWall 1 Window Information:4 5 6 Name FRONT LEFT BACK GD Library Type U-.29, SHGC-.27 U-.30, SHGC-.26 U-.30, SHGC-.26 U-Value 0.290 0.300 0.300 SHGC 0.270 0.260 0.260 Area(sq ft) 101.00 190.00 48.00 Orientation Southwest North North Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 1 AGWall 1 AGWall 1 BUILDING FILE REPORT PATEL Page 10 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Window Information:7 8 9 Name GD GD BACK LEFT Library Type U-.30, SHGC-.26 U-.30, SHGC-.26 U-.30, SHGC-.26 U-Value 0.300 0.300 0.300 SHGC 0.260 0.260 0.260 Area(sq ft) 24.00 40.00 232.00 Orientation North North Northwest Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 1 AGWall 1 AGWall 1 Window Information:10 11 12 Name BACK LEFT GD BACK RIGHT BACK RIGHT GD Library Type U-.30, SHGC-.26 U-.30, SHGC-.26 U-.30, SHGC-.26 U-Value 0.300 0.300 0.300 SHGC 0.260 0.260 0.260 Area(sq ft) 24.00 91.00 180.00 Orientation Northwest Northeast Northeast Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 1 AGWall 1 AGWall 1 BUILDING FILE REPORT PATEL Page 11 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Window Information:13 14 Name LEFT SIDE RIGHT SIDE Library Type U-.29, SHGC-.27 U-.29, SHGC-.27 U-Value 0.290 0.290 SHGC 0.270 0.270 Area(sq ft) 132.00 150.00 Orientation West East Overhang Depth 0.0 0.0 Overhang To Top 0.0 0.0 Overhang To Bottom 0.0 0.0 Interior Winter Shading 0.85 0.85 Interior Summer Shading 0.70 0.70 Adjacent Winter Shading None None Adjacent Summer Shading None None Wall Assignment AGWall 1 AGWall 1 Window: U-.29, SHGC-.27 U-Value: 0.290 Solar Heat Gain Coefficient: 0.270 Note: Window: U-.30, SHGC-.26 U-Value: 0.300 Solar Heat Gain Coefficient: 0.260 Note: Door Information:1 2 Name GARAGE GARAGE Opaque Area(sq ft) 24.0 24.0 Library Type Steel-urth w/brk Steel-urth w/brk Wall Assignment AGWall 2 AGWall 2 Uo Value 0.187 0.187 Door: Steel-urth w/brk R-Value of Opaque Area: 4.4 Storm Door: No Note: BUILDING FILE REPORT PATEL Page 12 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Roof Information:1 Name MAIN Library Type R-50, Attic GR1 Ceiling Area(sq ft) 4409.00 Roof Area(sq ft) 4409.00 Color Medium Radiant Barrier No Type(Attic) Attic Uo Value 0.020 Clay or Cement Tiles: No Sub Roof Ventilation: No BUILDING FILE REPORT PATEL Page 13 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Ceiling: R-50, Attic GR1 Information From Quick Fill Screen: Continous Insulation (R-Value) 37.0 Cavity Insulation (R-Value) 13.0 Cavity Insulation Thickness (in) 3.5 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in)1.5 x 3.5 Insulated Framing Spacing (in o.c.) 24.0 Framing Factor - (default)0.1100 Ceiling Type Attic Note: Layers Paths Framing Cavity Grade Inside Air Film 0.610 0.610 0.610 Gyp board 0.450 0.450 0.450 Cavity Ins/Frm 4.375 13.000 0.000 Continuous ins 37.000 37.000 37.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Outside Air Film 0.610 0.610 0.610 Total R-Value 43.045 51.670 38.670 U-Value 0.023 0.019 0.026 Relative Area 0.110 0.890 0.000 UA 0.003 0.017 0.000 Total Component UA: 0.020 Total Component Area: 1.0 Component Uo: 0.020 BUILDING FILE REPORT PATEL Page 14 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Mechanical Equipment: General Number of Mechanical Systems: 7 Heating SetPoint(F): 68.00 Heating Setback Thermostat: Present Cooling SetPoint(F): 78.00 Cooling Setup Thermostat: Present Heat: 912SA48080S17A SystemType: Fuel-fired air distribution Fuel Type: Natural gas Rated Output Capacity (kBtuh): 78.0 Seasonal Equipment Efficiency: 92.1 % EFF Auxiliary Electric: 977 Eae Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 33 Number Of Units: 1 Heat: 912SA48080S17A SystemType: Fuel-fired air distribution Fuel Type: Natural gas Rated Output Capacity (kBtuh): 78.0 Seasonal Equipment Efficiency: 92.1 % EFF Auxiliary Electric: 977 Eae Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 33 Number Of Units: 1 BUILDING FILE REPORT PATEL Page 15 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Heat: 912SA48080S17A SystemType: Fuel-fired air distribution Fuel Type: Natural gas Rated Output Capacity (kBtuh): 78.0 Seasonal Equipment Efficiency: 92.1 % EFF Auxiliary Electric: 977 Eae Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 33 Number Of Units: 1 Cooling Equipment: 13ACX-042-230 System Type:Air conditioner Fuel Type: Electric Rated Output Capacity (kBtuh): 41.5 Seasonal Equipment Efficiency: 13.0 SEER Sensible Heat Fraction (SHF): 0.70 Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 33 Number Of Units: 1 Cooling Equipment: 13ACX-042-230 System Type:Air conditioner Fuel Type: Electric Rated Output Capacity (kBtuh): 41.5 Seasonal Equipment Efficiency: 13.0 SEER Sensible Heat Fraction (SHF): 0.70 Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 33 Number Of Units: 1 BUILDING FILE REPORT PATEL Page 16 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Cooling Equipment: 13ACX-042-230 System Type:Air conditioner Fuel Type: Electric Rated Output Capacity (kBtuh): 41.5 Seasonal Equipment Efficiency: 13.0 SEER Sensible Heat Fraction (SHF): 0.70 Note: Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 33 Number Of Units: 1 Water Heating Equipment: RE350T*** Water Heater Type: Conventional Fuel Type: Electric Energy Factor: 0.95 Recovery Efficiency: 0.98 Water Tank Size (gallons): 50 Extra Tank Insulation (R-Value): 0.0 Note: Location: Conditioned area Percent Load Served: 100 Performance Adjustment: 100 Number Of Units: 1 DHW Efficiencies All bath faucets & showers <= 2gpm: false All DHW pipes fully insulated >= R-3: false Recirculation type: None (standard system) Farthest fixture to DHW heater 55 TOTAL Pipelength for longest DHW run: 85 DWHR unit present?: false BUILDING FILE REPORT PATEL Page 17 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Duct System Information: Name SYSTEM 1 Heating System 912SA48080S17A Cooling System 13ACX-042-230 Supply Area(sq ft) 237.9 Return Area(sq ft) 176.3 Conditioned Floor Area(sq ft) 3525.0 # of Registers 4 Duct Leakage Qualitative Assessment - Not Applicable Duct Leakage to Outside: 210.00 CFM @ 25 Pascals Supply Duct Leakage - Not Applicable Return Duct Leakage - Not Applicable Total Duct Leakage: 280.00 CFM @ 25 Pascals Duct Tightness Test: Postconstruction Test Duct Information:1 2 3 Type Supply Return Supply Percent Area 40.0 40.0 30.0 R-Value 6.0 6.0 6.0 Location Conditioned basement Conditioned basement Conditioned space Duct Information:4 5 6 Type Return Supply Return Percent Area 30.0 30.0 30.0 R-Value 6.0 30.0 30.0 Location Conditioned space Attic, under insulation Attic, under insulation Duct System Information: Name SYSTEM 2 Heating System 912SA48080S17A Cooling System 13ACX-042-230 Supply Area(sq ft) 237.9 Return Area(sq ft) 176.3 Conditioned Floor Area(sq ft) 3525.0 # of Registers 4 Duct Leakage Qualitative Assessment - Not Applicable Duct Leakage to Outside: 210.00 CFM @ 25 Pascals Supply Duct Leakage - Not Applicable Return Duct Leakage - Not Applicable Total Duct Leakage: 280.00 CFM @ 25 Pascals Duct Tightness Test: Postconstruction Test BUILDING FILE REPORT PATEL Page 18 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Duct Information:1 2 3 Type Supply Return Supply Percent Area 40.0 40.0 30.0 R-Value 6.0 6.0 6.0 Location Conditioned basement Conditioned basement Conditioned space Duct Information:4 5 6 Type Return Supply Return Percent Area 30.0 30.0 30.0 R-Value 6.0 30.0 30.0 Location Conditioned space Attic, under insulation Attic, under insulation Duct System Information: Name SYSTEM 3 Heating System 912SA48080S17A Cooling System 13ACX-042-230 Supply Area(sq ft) 237.9 Return Area(sq ft) 176.2 Conditioned Floor Area(sq ft) 3524.0 # of Registers 4 Duct Leakage Qualitative Assessment - Not Applicable Duct Leakage to Outside: 210.00 CFM @ 25 Pascals Supply Duct Leakage - Not Applicable Return Duct Leakage - Not Applicable Total Duct Leakage: 280.00 CFM @ 25 Pascals Duct Tightness Test: Postconstruction Test Duct Information:1 2 3 Type Supply Return Supply Percent Area 40.0 40.0 30.0 R-Value 6.0 6.0 6.0 Location Conditioned basement Conditioned basement Conditioned space Duct Information:4 5 6 Type Return Supply Return Percent Area 30.0 30.0 30.0 R-Value 6.0 30.0 30.0 Location Conditioned space Attic, under insulation Attic, under insulation BUILDING FILE REPORT PATEL Page 19 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Infiltration and Mechanical Ventilation Whole House Infiltration Measurement Type: Blower door test Heating Season Infiltration Value: 6.00 ACH @ 50 Pascals Cooling Season Infiltration Value: 6.00 ACH @ 50 Pascals Shelter Class 4 Code Verification: Tested Mechanical Ventilation for IAQ Type: None Rate(cfm): 0 Sensible Recovery Efficiency(%): 0.00 Total Recovery Efficiency(%): 0.00 Hours per Day: 24.00 Fan Power (watts): 0.00 ECM Fan Motor: false Ventilation Strategy for Cooling Cooling Season Ventilation: Natural Ventilation Lights and Appliances Simplified Audit Refrigerator KWh: 691 Refrigerator Location: Conditioned Dishwasher EF: 0.46 Dishwasher kWh/yr: 0 Dishwasher Capacity: 12 Dishwasher kWh/Year: 0 Range/Oven Fuel Type: Electric Induction Range: No Convection Oven: No Clothes Dryer Fuel Type: Electric Clothes Dryer Location: Conditioned Clothes Dryer Moisture Sensing: No Clothes Dryer Energy Factor: 3.01 Clothes Dryer Gas Energy Factor: 2.67 Clothes Washer Location: Conditioned Clothes Washer LER: 704.0 Clothes Washer MEF: 0.817 Clothes Washer Capacity: 2.874 Clothes Washer Electricity Rate: 0.08 BUILDING FILE REPORT PATEL Page 20 REM/Rate - Residential Energy Analysis and Rating Software v15.3 © 1985-2016 Noresco, Boulder, Colorado. Lights and Appliances Clothes Washer Gas Rate: 0.58 Clothes Washer Annual Gas Cost: 23.00 Percent CFLs: 0.0 Percent Fluorescent: 10.0 Percent Exterior Lights: 0.0 Percent Garage Lights: 0.0 Ceiling Fan CFM / Watt: 0.00 Mandatory Requirements IECC Requirements Verified IECC 04: true Verified IECC 06: true Verified IECC 09: true Verified IECC 12: false Verified IECC 15: false Verified NY-ECCC 2010: false Verified Michigan: false Rater certifies that the home complies with the following requirements for: None Rater Design Review Checklist (National) Rater Field Checklist(National) HVAC Design Report HVAC Commissioning Checklist (optional) ENERGY STAR Version 3 Appliances Refrigerators: 0 Ceiling Fans: 0 Exhaust Fans: 0 Dishwashers: 1 ENERGY STAR Version 3 Basements Basement Wall Area 50% Below Grade: true Basement Floor Area: 4390 2009 IECC Prescriptive Requirements for ENERGY STAR v3.0 false Slab Insulation Exemption: false Indoor airPlus Verification Checklist: false EPA Field App ID ENERGY CODE INSPECTION CHECKLIST Date:August 13, 2018 Rating No.: Building Name: PATEL Rating Org.: TSI ENERGY SOLUTIONS Owner's Name: HOMES BY MCKENZIE, INC Phone No.: 317-846-4655 Property: 11151 HINTOCKS CIR Rater's Name: MICHAEL HILL Address: CARMEL (AS DESIGNED), IN 46032 Rater's No.: 9479271 Builder's Name: HOMES BY McKENZIE, INC Weather Site: Indianapolis, IN Rating Type: Projected Rating File Name: PATEL_MCKENZIE_CODE.blg Rating Date: 08/13/2018 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Building Information: Conditioned Area (sq ft): 10574 Conditioned Volume (cubic ft): 119917 Insulated Shell Area (sq ft): 18857 The building assemblies and the energy features listed below have been modeled to demonstrate compliance with theIECC utilizing the Simulated Performance Path. At times the energy features listed below will change in the field from what has been input in the analysis. TSI ENERGY SOLUTIONS's field inspection process will identify any changes to ensure that the home continues to meet the intent of the IECC. Reports and certificates will be furnished before CO to ensure that the house meets the intent of the IECC. Ceilings: [ ] 1.Attic: R-50, Attic GR1 (4409 s.f.) R-37.0 continuous insulation, R-13.0 cavity insulation. Name: MAIN Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Above-Grade Walls: [ ] 1. Wall: G1 R-15 BATT, OSB (5056 s.f.), Between conditioned space and ambient R-0.5 continuous insulation, R-15.0 cavity insulation. Name: COND/AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Wall: G1 R-15 Gar Walls (408 s.f.), Between conditioned space and garage R-0.0 continuous insulation, R-15.0 cavity insulation. Name: COND/GAR Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ ENERGY CODE INSPECTION CHECKLIST PATEL Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. [ ] 3. Wall: G1 R-15 BATT, OSB (1352 s.f.), Between conditioned space and garage R-0.5 continuous insulation, R-15.0 cavity insulation. Name: COND/ATTIC Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Windows and Skylights: Window-to-Wall Area Ratio: 0.25 [ ] 1. Window: U-.29, SHGC-.27 (417 s.f., South), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: FRONT Orientation: South Comments/Location___________________________________________________________ [ ] 2. Window: U-.29, SHGC-.27 (48 s.f., South), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: GD Orientation: South Comments/Location___________________________________________________________ [ ] 3. Window: U-.29, SHGC-.27 (60 s.f., South), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: GD Orientation: South Comments/Location___________________________________________________________ [ ] 4. Window: U-.29, SHGC-.27 (101 s.f., Southwest), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: FRONT LEFT Orientation: Southwest Comments/Location___________________________________________________________ [ ] 5. Window: U-.30, SHGC-.26 (190 s.f., North), U-Value: 0.300, SHGC: 0.260 For windows without labeled U-factors, describe features: Name: BACK Orientation: North Comments/Location___________________________________________________________ [ ] 6. Window: U-.30, SHGC-.26 (48 s.f., North), U-Value: 0.300, SHGC: 0.260 For windows without labeled U-factors, describe features: Name: GD Orientation: North ENERGY CODE INSPECTION CHECKLIST PATEL Page 3 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Comments/Location___________________________________________________________ [ ] 7. Window: U-.30, SHGC-.26 (24 s.f., North), U-Value: 0.300, SHGC: 0.260 For windows without labeled U-factors, describe features: Name: GD Orientation: North Comments/Location___________________________________________________________ [ ] 8. Window: U-.30, SHGC-.26 (40 s.f., North), U-Value: 0.300, SHGC: 0.260 For windows without labeled U-factors, describe features: Name: GD Orientation: North Comments/Location___________________________________________________________ [ ] 9. Window: U-.30, SHGC-.26 (232 s.f., Northwest), U-Value: 0.300, SHGC: 0.260 For windows without labeled U-factors, describe features: Name: BACK LEFT Orientation: Northwest Comments/Location___________________________________________________________ [ ] 10. Window: U-.30, SHGC-.26 (24 s.f., Northwest), U-Value: 0.300, SHGC: 0.260 For windows without labeled U-factors, describe features: Name: BACK LEFT GD Orientation: Northwest Comments/Location___________________________________________________________ [ ] 11. Window: U-.30, SHGC-.26 (91 s.f., Northeast), U-Value: 0.300, SHGC: 0.260 For windows without labeled U-factors, describe features: Name: BACK RIGHT Orientation: Northeast Comments/Location___________________________________________________________ [ ] 12. Window: U-.30, SHGC-.26 (180 s.f., Northeast), U-Value: 0.300, SHGC: 0.260 For windows without labeled U-factors, describe features: Name: BACK RIGHT GD Orientation: Northeast Comments/Location___________________________________________________________ [ ] 13. Window: U-.29, SHGC-.27 (132 s.f., West), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: ENERGY CODE INSPECTION CHECKLIST PATEL Page 4 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Name: LEFT SIDE Orientation: West Comments/Location___________________________________________________________ [ ] 14. Window: U-.29, SHGC-.27 (150 s.f., East), U-Value: 0.290, SHGC: 0.270 For windows without labeled U-factors, describe features: Name: RIGHT SIDE Orientation: East Comments/Location___________________________________________________________ Doors: [ ] 1. Door: Steel-urth w/brk (24 s.f.), R-Value 4.4 Comments/Location___________________________________________________________ [ ] 2. Door: Steel-urth w/brk (24 s.f.), R-Value 4.4 Comments/Location___________________________________________________________ Floors: [ ] 1. Floor: GR-1 R-30 (19 s.f.), Between conditioned space and ambient conditions R-0.0 continuous insulation, R-30.0 cavity insulation. Name: OVER AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Foundation Walls: [ ] 1. Wall: R-11 Finished (430 s.f.), Between conditioned space and ambient/ground R-0.5 interior continuous insulation, R-11.0 interior cavity insulation, R-0.0 exterior insulation. Name: COND/AMB FIN Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Wall: R-10 Draped, 4' (1890 s.f.), Between conditioned space and ambient/ground R-10.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: COND/AMB UNFIN Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 3. Wall: R-11 Finished (120 s.f.), Between conditioned space and ambient/ground R-0.5 interior continuous insulation, R-11.0 interior cavity insulation, R-0.0 exterior insulation. ENERGY CODE INSPECTION CHECKLIST PATEL Page 5 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Name: COND/GAR FIN Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 4. Wall: R-10 Draped, 4' (220 s.f.), Between conditioned space and ambient/ground R-10.0 interior continuous insulation, R-0.0 interior cavity insulation, R-0.0 exterior insulation. Name: COND/GAR UNFIN Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Slab Floors: [ ] 1. Slab: Uninsulated (3987 s.f.) R-0.0 perimeter insulation, R-0.0 under slab insulation. Name: BSMT Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Slab: R-10, 2'down, 2' in (403 s.f.) R-10.0 perimeter insulation, R-10.0 under slab insulation. Name: SLAB WO Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ Rim and Band Joists: [ ] 1. Joist: COND/AMB (362 s.f.), Between conditioned space and ambient R-0.5 continuous insulation, R-15.0 cavity insulation. Name: COND/AMB Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 2. Joist: COND/GAR (34 s.f.), Between conditioned space and garage R-0.5 continuous insulation, R-15.0 cavity insulation. Name: COND/GAR Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ [ ] 3. Joist: COND/ATTIC (167 s.f.), Between conditioned space and attic R-0.5 continuous insulation, R-15.0 cavity insulation. Name: COND/ATTIC Insulation Grade: I II III Face / Inset Comments/Location___________________________________________________________ ENERGY CODE INSPECTION CHECKLIST PATEL Page 6 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Mechanical Equipment: [ ] 1. Heating: Fuel-fired air distribution, Natural gas, 92.1 % EFF. Make and Model Number:_____________________________________________________ [ ] 2. Heating: Fuel-fired air distribution, Natural gas, 92.1 % EFF. Make and Model Number:_____________________________________________________ [ ] 3. Heating: Fuel-fired air distribution, Natural gas, 92.1 % EFF. Make and Model Number:_____________________________________________________ [ ] 4. Cooling: Air conditioner, Electric, 13.0 SEER. Make and Model Number:_____________________________________________________ [ ] 5. Cooling: Air conditioner, Electric, 13.0 SEER. Make and Model Number:_____________________________________________________ [ ] 6. Cooling: Air conditioner, Electric, 13.0 SEER. Make and Model Number:_____________________________________________________ [ ] 7. Water Heating: Conventional, Electric, 0.95 EF, 50.0 Gal. Make and Model Number:_____________________________________________________ Air Leakage Control: [ ] Blower Door Test at Final __________________________ [ ] House is air-sealed so as to achieve 6.00 ACH50 or less at final blower door test. (Max CFM50 is: 11992) [ ] Visual inspection at rough for mandatory code air barrier and insulation features. INFILTRATION REQUIREMENTS FOR IECC. 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. ENERGY CODE INSPECTION CHECKLIST PATEL Page 7 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Duct Leakage and Insulation: [ ] Duct System 1 Leakage to Outside _________________________ and Total Duct Leakage _________________________ [ ] Duct System 1 Leakage to Outside is specified in REM/Rate at 210.000 CFM @ 25 Pascals [ ] Duct System 1 Total Duct Leakage is specified in REM/Rate at 280.000 CFM @ 25 Pascals [ ] Duct System 2 Leakage to Outside _________________________ and Total Duct Leakage _________________________ [ ] Duct System 2 Leakage to Outside is specified in REM/Rate at 210.000 CFM @ 25 Pascals [ ] Duct System 2 Total Duct Leakage is specified in REM/Rate at 280.000 CFM @ 25 Pascals [ ] Duct System 3 Leakage to Outside _________________________ and Total Duct Leakage _________________________ [ ] Duct System 3 Leakage to Outside is specified in REM/Rate at 210.000 CFM @ 25 Pascals [ ] Duct System 3 Total Duct Leakage is specified in REM/Rate at 280.000 CFM @ 25 Pascals DUCT LEAKAGE CODE REQUIREMENTS FOR IECC 2009 IECC Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. 2009 IECC Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. 2009 IECC Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. NOTES 2009 IECC ANNUAL ENERGY COST COMPLIANCE Date:August 13, 2018 Rating No.: Building Name: PATEL Rating Org.: TSI ENERGY SOLUTIONS Owner's Name: HOMES BY MCKENZIE, INC Phone No.: 317-846-4655 Property: 11151 HINTOCKS CIR Rater's Name: MICHAEL HILL Address: CARMEL (AS DESIGNED), IN 46032 Rater's No.: 9479271 Builder's Name: HOMES BY McKENZIE, INC Weather Site: Indianapolis, IN Rating Type: Projected Rating File Name: PATEL_MCKENZIE_CODE.blg Rating Date: 08/13/2018 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Annual Energy Cost ($) 2009 IECC As Designed Heating:2824 3229 Cooling:750 645 Water Heating: 531 531 SubTotal - Used to Determine Compliance:4105 4405 Lights & Appliances: 2344 2344 Photovoltaics:-0 -0 Service Charge: 248 248 Total:6697 6996 * Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.480 0.295 Home Infiltration (Section 402.4.2):PASSES Duct Leakage (Section 403.2.2):PASSES This home DOES NOT meet the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code based on a climate zone of 5A. Name:MICHAEL HILL Signature: Organization:TSI ENERGY SOLUTIONS Date:August 13, 2018 * Design energy cost is based on the following systems: Heating: Fuel-fired air distribution, 78.0 kBtuh, 92.1 % EFF. Heating: Fuel-fired air distribution, 78.0 kBtuh, 92.1 % EFF. Heating: Fuel-fired air distribution, 78.0 kBtuh, 92.1 % EFF. Cooling: Air conditioner, 41.5 kBtuh, 13.0 SEER. Cooling: Air conditioner, 41.5 kBtuh, 13.0 SEER. Cooling: Air conditioner, 41.5 kBtuh, 13.0 SEER. Water Heating: Conventional, Elec, 0.95 EF. Window-to-Floor Area Ratio: 0.16 Blower door test: Htg: 6.00 Clg: 6.00 ACH50 2009 IECC ANNUAL ENERGY COST COMPLIANCE PATEL Page 2 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. HOME CERTIFIED TO MEET THE PROVISIONS OF THE2009 INTERNATIONAL ENERGY CONSERVATION CODEThis home built at11151 HINTOCKS CIR, CARMEL (AS DESIGNED), INby HOMES BY McKENZIE, INCexceeds the minimum requirements for the 2009 International Energy Conservation CodeBuilding FeaturesCeiling Flat: R-50.0 Duct Leakage to Outside: 210.00 CFM @ 25 PascalsSealed Attic: NA Total Duct Leakage: 280.00 CFM @ 25 PascalsVaulted Ceiling: NA Infiltration: Htg: 6.00 Clg: 6.00 ACH50Above Grade Walls: R-15.5 Window: U-Value: 0.290, SHGC: 0.270Foundation Walls: R-10.0 Heating Fuel-fired air distribution, Natural gas, 92.1 % EFF.Exposed Floor: R-30.0 CoolingAir conditioner, Electric, 13.0 SEER.Slab: R-0.0 Edge, R-0.0 Under Water Heating Conventional, Electric, 0.95 EF, 50.0 Gal.Duct: NA08/13/2018The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and othercalculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in compliance withChapter 4 based on Climate Zone 5A and with all mandatory requirements.Name:MICHAEL HILL Signature:Organization:TSI ENERGY SOLUTIONS Date:August 13, 2018The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”).No version of this software has been reviewed or approved by ICC or its affiliates.REM/Rate - Residential Energy Analysis and Rating Software v15.3