Loading...
HomeMy WebLinkAbout 0778.01 Truss PlansI Attachments: Notes 4-0-0_,a 20-8-0 DiQ 16-4-0 Dia 12-8-0 D *** NOT TO SCALE *** -s- 4-0-0 22-0-0 1 21-0-0 2 _0 I_4-0-0 a 21-0-0 9-3-8 9-9-0 a 9-7-8 _I T M C TRUSS MANUFACTURING COMPANY INC. PO BOX 418 WESTFIELD IND 46074 WHERE QUALITY COUNTS CENTEX HOMES - DESIGNER SERIES LAURENS (2546) - ELEVATION 4' FAM RM EXT / OWNERS CATH CLG -I- 4-0-0 32-2-0 2-7-0 10-3-0 1 Job Name: RL0023 Customer: 1018 Designer: TCS Checker: TC Live 20.0 TC Dead 10.0 BC Live 0.0 BC Dead 10.0 TOTAL 40.0 PSF # Components: 58 WO: 48519 WOE: LAURENS Date: 2-10-00 12:41:48 Lbr DurFac: 1.15 Pit DurFac: 1.15 Spacing: 24.0" Design Criteria: TPI JOB PATH: TATEE-LOKUOB.SITi 1PIROBICENTM001MOTSIRI. Notes and Specifications Note #1 (25 locations): Note #2: Use Simpson HUS-26 hangers here to provide the proper truss- Please review all of the information contained in the engineered to -truss connections. truss drawings, the TPI "HIB-91" summary sheet, and the WTCA materials contained in the delivery packet for temporary bracing, Total number of Simpson HUS-26 hangers required = 25 EACH erection, and other special design requiremnets. Note #3 (10 locations): SIMPSON TC24 SCISSOR TRUSS TO WALL CONNECTION TO ALLOW FOR MOVEMENT OF TRUSSES ON TOP PLATE OF WALL ( 10 REQ'D ) T M C TRUSS MANUFACTURING COMPANY INC. CENTEX HOMES - DESIGNER SERIES PO BOX 418 LAURENS (2546) - ELEVATION WESTFIELD IND 46074 4' FAM RM EXT / OWNERS CA'1 ri CLG WHERE QUALITY COUNTS JOB PATH: T:ITF_F,-LOKUOB-SITf. PIBOBICFNTFXIOIXXN,OTSIRL Job Name: RL0023 Customer: 1018 Designer: TCS Checker: WO: 48519 WOE: LAURENS Date: 2-10-00 12:41:48 TC Live 20.0 Lbr DurFac: 1.15 TIC Dead 10.0 Pit DurFac: 1.15 BC Live 0.0 Spacing: 24.0" BC Dead 10.0 Design Criteria: TPl TOTAL 40.0 PSF Va01,01 " RL0023 v�;uiunri, TRUSS MANUFACTURING CO., INC. PO BOX 418 WESTFIELD IN 46074 (317)896-2571 V: 01.01.00 - RL0023 Job Name: RL0023 Work Order: 48519 Designer: TCS Design Crit: TPI Date: 2-10-00 12:41:50 Customer: 1018 WO Extn: LAURENS Checker: Description: TPI 1-1995 #Tr/#Cfg: 58/27 Page: 1 QTY ..SPAN.. LABEL.. HEELS.. ..OHNGS... CANTS.. 1 4 32- 2- 0 A (L) 0- 4- 9 1- 0- 0 COMN ST (R) 0- 4- 9 1- 0- 0 2 2 32- 2- 0 Al (L) 0- 4- 9 1- 0- 0 COMN ST (R) 0- 4- 9 3 1 32- 2- 0 AGE (L) 0- 4- 9 1- 0- 0 CCHN ST (R) 0- 4- 9 1- 0- 0 ** Continuous Support ** 4 1 32- 2- 0 ASC (L) 0- 4- 9 1- 0- 0 COMN ST (R) 0- 4- 9 1- 0- 0 5 10 13- 4-11 B (L) 0- 4- 9 MONO ST (R) 9- 3-11 6 1 13- 4-11 BGE (L) 0- 4- 9 MONO ST (R) 9- 3-11 ** Continuous Support ** 7 5 25- 1- 0 CC (L) 0- 4- 9 SPEC ST (R) 0- 4- 9 1- 0- 0 8 1 25- 1- 0 CM (L) 0- 4- 9 SPEC ST (R) 0- 4- 9 1- 0- 0 9 1 25- 1- 0 CC2 (L) 0- 4- 9 SPEC ST (R) 0- 4- 9 1- 0- 0 10 3 25- 1- 0 CC3 (L) 0- 4- 9 SPEC ST (R) 0- 4- 9 1- 0- 0 11 1 25- 1- 0 CGE (L) 0- 4- 9 1- 0- 0 COMN ST (R) 0- 4- 9 1- 0- 0 ** Continuous Support ** 12 1 6- 3-11 DGE (L) 0- 4- 9 MONO ST (R) 4- 7- 1 ** Continuous Support ** 13 3 21- 0- 0 E (L) 0- 6- 9 1- 0- 0 COMP) ST (R) 0- 6- 9 1- 0- 0 14 1 21- 0- 0 EGE (L) 0- 6- 9 1- 0- 0 CCMN ST (R) 0- 6- 9 1- 0- 0 ** Continuous Support ** 15 1 21- 0- 0 EGR (L) 0- 6- 9 COMN ZZ (R) 0- 6- 9 #PLYS = 2 16 1 9- 9- 0 F (L) 0- 6- 9 1- 0- 0 COMN ST (R) 0- 6- 9 1- 0- 0 17 1 9- 9- 0 FGE (L) 0- 6- 9 1- 0- 0 CCMN ST (R) 0- 6- 9 1- 0- 0 18 1 9- 9- 0 FGR (L) 0- 6- 9 COHN ST (R) 0- 6- 9 #PLYS = 2 19 5 36- 2- 0 G (L) 0- 4- 9 2- 0- 0 SPEC ST (R) 0- 4- 9 1- 0- 0 ..PITCHES AND OTHER DATA....... #TC 2 PCH: 8.0 -8.0 #TC 2 PCH: 8.0 -8.0 #TC 2 PCH: 8.0 -8.0 #TC 2 PCH: 8.0 -8.0 PCH: 8.0 PCH: 8.0 #TC #BC 2 5 PCH: PCH:0.0 .0 .0 99999.0 4.0 #TC #BC 2 5 PCH: PCH: .0 .0 0 .0 99999.0 4.0 #TC #BC 2 5 PCH: PCH: .0 -8.0 0 .0 999.0 4.0 #TC #BC 2 5 PCH: PCH: .0 0.0 99999.0 4.0 #TC 2 PCH: 8.0 -8.0 PCH: 8.0 #TC 2 PCH: 10.0 -10.0 #TC 2 PCH: 10.0 -10.0 #TC 2 PCH: 10.0 -10.0 #TC 2 PCH: 10.0 -10.0 #BAGS 4 #TC 2 PCH: 10.0 -10.0 #TC 2 #BRGS 3 PCH: 10.0 -10.0 #TC 3 PCH: 4.0 8.0 -8.0 TRUSS MANUFACTURING CO., INC. PO BOX 418 WESTFIELD IN 46074 (317)896-2571 V: 01.01.00 - RL0023 Job Name: RL0023 Work Order: 48519 Designer: TCS Design Crit: TPI Date: 2-10-00 12:41:50 Customer: 1018 WO Extn: LAURENS Checker: Description: TPI 1-1995 #Tr/#Cfg: 58/27 Page: 2 QTY ..SPAN.. LABEL.. HEELS.. ..OHNGS... CANTS.. ..PITCHES AND OTHER DATA....... 20 3 36- 2- 0 G1 (L) 0- 4- 9 2- 0- 0 #TC 3 PCH: 4.0 8.0 -8.0 SPEC ST (R) 0- 4- 9 21 2 4- 0- 0 HGE (L) 0- 4- 9 2- 0- 0 PCH: 4.0 MONO ST (R) 1- 8- 9 ** Continuous Support ** 22 2 3- 0- 0 VA011008 (L) #TC 2 PCH: 10.0 -10.0 COMN ST (R) ** Continuous Support ** 23 2 6- 2- 6 VA021008 (L) #TC 2 PCH: 10.0 -10.0 COMN ST (R) ** Continuous Support ** 24 2 9- 4-13 VA031008 (L) #TC 2 PCH: 10.0 -10.0 DUBLBL ST (R) ** Continuous Support ** 25 1 12- 7- 3 VA041008 (L) #TC 2 PCH: 10.0 -10.0 DUHL ST (R) ** Continuous Support ** 26 1 15- 9-10 VA051008 (L) #TC 2 PCH: 10.0 -10.0 COMN ST (R) ** Continuous Support ** 27 1 19- 0- 0 VA061008 (L) #TC 2 PCH: 10.0 -10.0 COMN ST (R) ** Continuous Support ** 3 TC FORCE AXL BND CSI BC FORCE AXL BND CSI WEB 45- 2 44- 3 43- 4 42- 5 41- 6 40- 7 39- 8 38- 9 37-10 36-11 35-12 34-13 33-14 32-15 31-16 30-17 29-18 28-19 27-20 26-21 25-22 FORCE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 AXL BND CSI 0.00 0.07 0.07 0.00 0.15 0.15 0.00 0.27 0.27 0.00 0.42 0.42 0.00 0.63 0.63 0.00 0.82 0.82 0.00 0.61 0.61 0.00 0.96 0.96 0.00 0.68 0.68 0.00 0.82 0.82 0.00 0.98 0.98 0.00 0.82 0.82 0.00 0.68 0.68 0.00 0.96 0.96 0.00 0.61 0.61 0.00 0.82 0.82 0.00 0.63 0.63 0.00 0.42 0.42 0.00 0.27 0.27 0.00 0.15 0.15 0.00 0.07 0.07 WEB FORCE WEB FORCE RMB = 1.15 .SON\o �E.+f STf F No. F l ti442 STATE OF= = ' -ANC P F FSSI0 N NL LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SP #2 2X4 SPF #1/#2 (N) 2 GABLE STUD: 2x3 SPF #3 (N) 2x3 SPF #1/#2 (N) 7,15 2x4 SPF #3 (N) 8,14 2x4 SPF #1/#2 (N) 9,10,11,12 13 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. MULTIPLE LOADS -- This design is the composite result of multiple loads. WO: 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. or a SCAB of the same dimension and grade as web nailed to face(s) of web with 10d nails staggered 8" o.c. SCAB or TRANSVERSE BRACING to extend for 80% of web length. 2X6 BRACE req'd on any web exceeding 14' *" denotes ONE edge or ONE face denotes BOTH edges or BOTH faces Analysis based on Simplified Analog Model. [): Plate OFFSET from joint center. Refer to Joint Detail Report. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. Wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt.=15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. ======== ====Joint Locations=============_= 1) 0- 0- 0 17) 22- 9- 0 33) 18- 9- 0 2) 2- 9- 0 18) 24- 1- 0 34) 17- 5- 0 3) 4- 1- 0 19) 25- 5- 0 35) 16- 1- 0 4) 5- 5- 0 20) 26- 9- 0 36) 14- 9- 0 5) 6- 9- 0 21) 28- 1- 0 37) 13- 5- 0 6) 8- 1- 0 22) 29- 5- 0 38) 12- 1- 0 7) 9- 5- 0 23) 32- 2- 0 39) 10-10- 4 8) 10- 9- 0 24) 32- 2- 0 40) 9- 5- 0 9) 12- 1- 0 25) 29- 5- 0 41) 8- 1- 0 10) 13- 5- 0 26) 28- 1- 0 42) 6- 9- 0 11) 14- 9- 0 27) 26- 9- 0 43) 5- 5- 0 12) 16- 1- 0 28) 25- 5- 0 44) 4- 1- 0 13) 17- 5- 0 29) 24- 1- 0 45) 2- 9- 0 14) 18- 9- 0 30) 22- 9- 0 46) 0- 0- 0 15) 20- 1- 0 31) 21- 3-12 16) 21- 5- 0 32) 20- 1- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 0 0 0 BOT PIN 32- 0- 4 0 0 0 BOT H-ROLL 16-1-0 16-1-0 1 2 3 4 5 6 7 8 9 10 11 1 13 14 15 16 17 18 620 21 22 23 8 0000 -8 00 [6X6I -1.1 r, AV - LAY LAY GAY LAY 3X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 r f 32-2-0-TTr-�r-T-�� 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 0# 3.50" 0# 3.50" 1-0 1 le 32-2-0 �1-0-0 I' i EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs C 14-0 o.c. T M C WAKNIIV(i: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING TRUSS MANUFACTURING COMPANY INC. PO BOX 418 W ESTFI ELD IN D 46074 WHERE QUALITY COUNTS CONTRACTOR.BRACING WARNING: Bracing shown on this drawing is not erection bracing, wind bracing, portal hracing or similar bracing which is a pan of the building design and which must he comidcred by the building designer. Bracing shown is for lateral support of truss members only to reduce buckling length- Provisions must he made to anchor lateral bracing at ends and specilied locations determined by the building designer. Additional bracing of the overall structure may he required. (See HIB-91 of TPI). For specific truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located at 583D'Onofriu Drive. Madison, Wiscon•'- 9719). Design: Mm.ir AnaA•sis JOB PATH. C:ITF.F.-1,OK11f1N scale = 0.1250 Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: AGE Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - Plt: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code Dere: TPI 1-1995 TOTAL 40.0 psf V: 1.0- 160165-153 11('l ll! M 11) CENTEX TC FORCE AXL BND CSI 1- 2 -1851 0.16 0.74 0.91 2- 3 -1652 0.05 0.85 0.90 3- 4 -1652 0.05 0.86 0.91 4- 5 -1851 0.17 0.77 0.93 BC FORCE AXL BND CSI 10- 9 1444 0.29 0.41 0.70 9- 8 951 0.19 0.41 0.61 8- 7 951 0.23 0.46 0.70 7- 6 1444 0.35 0.46 0.82 WEB FORCE WEB FORCE 2- 9 -435 3- 7 692 3- 9 692 4- 7 -436 RMB = 1.15 �11t1)11u1"' %��0�\0 E. qR�,,�� G STD Z`QZ No. F az 16442 �STgTE OFE I N p� NA �4 < .O� ''0 ��`'FFSS10 N Al `11)infttf% �d /' , LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SP #2 2x4 SPF #1/#2 (N) 2 WEBS: 2x4 SPF STUD (N) 2x4 SPF #1/#2 (N) 2,3 GABLE STUD: 2x3 SPF #3 (N) 2x3 SPF #3 (N) 1,2,5,7,8 10 2x3 SPF #3 (N) 3,6,11 2x3 SPF #1/#2 (N) 4 MAX LIVE LOAD DEFLECTION: L/999 L=-0.10" D=-0.09" T=-0.19" MAX HORIZONTAL DEFLECTION: T= 0.07" WO: 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. [I: Plate OFFSET from joint center. Refer to Joint Detail Report. + Denotes 90 degree plate orientation. MULTIPLE LOADS -- This design is the composite result of multiple loads. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. TI: ASC TY:1 __============Joint Locations=============== 1) 0- 0- 0 5) 32- 2- 0 9) 10-10- 4 2) 8- 2-14 6) 32- 2- 0 10) 0- 0- 0 3) 16- 1- 0 7) 21- 3-12 4) 23-11- 3 8) 16- 2- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 1346 0 0 BOT PIN 32- 0- 4 1346 0 0 BOT H-ROLL Wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt.=15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. 16-1-0 16-1-0 1 2 4 5 8 00 -8 00 [6X61 4X5 R M L 32-2-0 L 110 -- 9 8 7 6 1347# 3.50" 1347# 3.50" 1-0-0 -3-7) j� 32-2-0 1-0-0 GABLE STUD PLATES (64)(��Ca-7) j EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs C 1-4-0 o.c. scale = 0.1250 T M C WAKNING: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR.BRACING TRUSS MANUFACTURING COMPANY INC. WARNING: Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is a part of the building design and which must he considered by the building designer. Bracing WESTFI ELD IN D 46074 shown is ror lateral support of truss members only to reduce buckling length. Provisions must he made to anchor lateral bracing at ends and specified locations determined by the building designer. WHERE QUALITY COUNTS Additional bracing of the overall structure may he required. (See HIB-91 of TPI). Eur specific truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located at 583 D'Onufrio Drive, Madison, Wiscun-- S3719). Design. Mettar AwNsis !OR PATH. QITEE_d OKiRIN Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: ASC Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - Plt: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code Desc: TPI 1-1995 TOTAL 40.0 psf V: 1. - 160164-152 ors of of rrt CENTEX TC FORCE AXL BND CSI 1- 2 -1851 0.16 0.74 0.91 2- 3 -1652 0.05 0.85 0.90 3- 4 -1652 0.05 0.86 0.91 4- 5 -1851 0.17 0.77 0.93 BC FORCE AXL END CSI 10- 9 1444 0.29 0.41 0.70 9- 8 951 0.19 0.41 0.61 8- 7 951 0.23 0.46 0.70 7- 6 1444 0.35 0.46 0.82 WEB FORCE WEB FORCE 2- 9 -435 3- 7 692 3- 9 692 4- 7 -436 RMB = 1.15 0 ,E"'�R�'''. S T� No. F 16442 STgrE OFF 1NDIIANA Pit- LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SP #2 2x4 SPF #1/#2 (N) 2 WEBS: 2x4 SPF STUD (N) 2x4 SPF #1/#2 (N) 2,3 MAX LIVE LOAD DEFLECTION: L/999 L=-0.10" D=-0.09" T=-0.19" MAX HORIZONTAL DEFLECTION: T= 0.07" WO: (): Plate OFFSET from joint center. Refer to Joint Detail Report. + Denotes 90 degree plate orientation. All COMPRESSION Chords are assim d to be continuously braced unless noted otherwise TI: A QTYA ========_=====Joint Locations=============== 1) 0- 0- 0 5) 32- 2- 0 9) 10-10- 4 2) 8- 2-14 6) 32- 2- 0 10) 0- 0- 0 3) 16- 1- 0 7) 21- 3-12 4) 23-11- 3 8) 16- 2- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 1346 0 0 BOT PIN 32- 0- 4 1346 0 0 BOT H-ROLL 16-1-0 16-1-0 1 2 4 5 8 00 -8 00 [6X61 11- f'.,, 4X5 n M G _ 32-2-0 '110 9 8 7 6 1347# 3.50" 1347# 3.50" 11 0-0_I L 32-2-0 1-0-00 (11-2-7) EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 scale = 0.1250 T M C WAKN 1 NG: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR.BRACING TRUSS MANUFACTURING COMPANY INC. WARNING: Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is a pan of the building design and which must he considered by the building designer. Bracing WESTFIELD IND 46074 shown is for lateral support of truss members only to reduce buckling length. Provisions must be made to anchor lateral bracing at ends and specified locations determined by the building designer. Additional bracing of the overall structure may he required. (See HIB-91 of TPI). For specific WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located at 583 D'Onofrio Drive, Madison, W iscur " `3719). Design- Moira Arioh-sis JOB PATH. CATFE-I.OSIRIN Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: A Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - Pit: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code De--: TPI 1-1995 TOTAL 40.0 psf 1 160166-154 /Wf Al 01 IV) CENTEX TIC FORCE AXL BND CSI 1- 2 -1851 0.16 0.74 0.91 2- 3 -1652 0.05 0.85 0.90 3- 4 -1652 0.05 0.86 0.91 4- 5 -1851 0.17 0.77 0.93 BC FORCE AXL BND CSI 10- 9 1444 0.29 0.41 0.70 9- 8 951 0.19 0.41 0.61 8- 7 951 0.23 0.46 0.70 7- 6 1444 0.35 0.46 0.82 WEB FORCE WEB FORCE 2- 9 -435 3- 7 692 3- 9 692 4- 7 -436 RMB = 1.15 \0 E 6442 STATE of INpN j�q A �OFFS F,��•`,�`` SIO N AL �'`��„,tiffs, LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SP #2 2x4 SPF #1/#2 (N) 2 WEBS: 2x4 SPF STUD (N) 2x4 SPF #1/#2 (N) 2,3 MAX LIVE LOAD DEFLECTION: L/999 L=-0.10" D=-0.09" T=-0.19" MAX HORIZONTAL DEFLECTION: T= 0.07" WO: L): Plate OFFSET from joint center. Refer to Joint Detail Report. + Denotes 90 degree plate orientation. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise T1: Al TY:2 ==_==_========Joint Locations=============== 1) 0- 0- 0 5) 32- 2- 0 9) 10-10- 4 2) 8- 2-14 6) 32- 2- 0 10) 0- 0- 0 3) 16- 1- 0 7) 21- 3-12 4) 23-11- 3 8) 16- 2- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 1346 0 0 BOT PIN 32- 0- 4 1286 0 0 BOT H-ROLL 16-1-0 16-1-0 1 2 4 5 8 00 -8 0000 (6X61 YAJ tJAD) JAD LJADJ 4P0 R 32-2-0 �10 9 8 7 6' 1347# 3.50" 1287# 3,50" 42 32_2_0 _ I 2-7) Iv EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TP1 1-1995 scale = 0.1250 T M C TRUSS MANUFACTURING WAKNIN4: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR. BRACING WARNING: Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: Al Date: 2-10-00 TIC Live 20.0 psf DurFac - Lbr: 1.15 COMPANY INC. Bracing shown "n this drawing is not erection bracing, wind bracing, portal bracing or similar bracing TC Dead 10.0 psf DurFac - Pit: 1.15 PO BOX 418 which is a part of the building design and which must be considered by the building designer. Bracing shown is for lateral support of truss to buckling length. BC Live 0.0 O.C. Spacing: 24.0" WESTFIELD IND 46074 members only reduce Provisions must he made to anchor lateral bracing at ends and specified locations determined by the building designer. psf Design Criteria: TPI WHERE QUALITY COUNTS Additional bracing ol'the overall structure may he required. (See HIB-91 of TPI). For specific truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is bleated at $C Dead 10.0 p sf Code Des: TPI 1-1995 583 D'Onofrio Drive, Madison, Wiscom' M19). TOTAL 40.0 psf V: 1.0' 160167-155 Design. Matrix Annlvsis JOB PATH: CITF.F-LOAIB/N IW% M M to CENTEX TC FORCE AXL SND CSI BC FORCE AXL BND CSI WEB FORCE AXL END CSI 20- 2 0 0.00 0.06 0.06 19- 3 0 0.00 0.14 0.14 18- 4 0 0.00 0.25 0.25 17- 5 0 0.00 0.40 0.40 16- 7 0 0.00 0.58 0.58 15- 8 0 0.00 0.79 0.79 14- 9 0 0.00 0.59 0.59 13-10 0 0.00 0.93 0.93 12-11 0 0.00 0.38 0.38 WEB FORCE WEB FORCE RMB = 1.15 �0 E. . No R , .Q= `CGScam. No,. c� 1b942 STATE OF= INDIANA 4<c�� IML F��``• /� �rlr�rrltn� LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SPF #1/#2 (N) WEBS: 2x4 SPF #3 (N) GABLE STUD: 2x3 SPF #3 (N) 2x3 SPF #1/#2 (N) 7 2x4 SPF #3 (N) 8 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. MULTIPLE LOADS -- This design is the composite result of multiple loads. End vertical(s) not designed for exposure to lateral wind pressure. WO: L 2X4 TRANSVERSE BRACING nailed flat to edge K^of web with 12d nails at 8" o.c. or a SCAB of the same dimension and grade as web nailed to face(s) of web with 10d nails staggered 8" o.c. SCAB or TRANSVERSE BRACING to extend for 80% of web length. 2X6 BRACE req'd on any web exceeding 14, denotes ONE edge or ONE face denotes BOTH edges or BOTH faces Analysis based on Simplified Analog Model. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. Wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt.=15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. 13-4-1 1 2 3 4 56 7 8 9 10 11 8 00 4X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 TI: BGE TY:I =_ ==Joint Locations======_======== 1) 0- 0- 0 8) 9- 2-15 15) 9- 2-15 2) 2- 6-15 9) 10- 6-15 16) 7-10-15 3) 3-10-15 10) 11-10-15 17) 6- 6-15 4) 5- 2-15 11) 13- 4-11 18) 5- 2-15 5) 6- 6-15 12) 13- 4-11 19) 3-10-15 6) 7- 0- 7 13) 11-10-15 20) 2- 6-15 7) 7-10-15 14) 10- 6-15 21) 0- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 0 0 0 BOT PIN 13- 2-15 0 0 0 BOT H-ROLL I. 1T 34-11 21 20 19 18 17 16 15 14 1' 0# 3.50" 0# 3.50" 13-4-11 I EXCEPT' AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs ® 14-0 ox T M C VV,KKI41N`tj: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING TRUSS MANUFACTURING CONTRACTOR.BRACING WARNING: COMPANY INC. Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is a pan of the building design and which must be considered by the building designer. Bracing WESTFIELD IND 46074 shown is tiff lateral support of truss members only to reduce buckling length. Provisions must he made to anchor lateral bracing at ends and specified locations determined by the building designer. Additional bracing of the overall structure may be required. (Sec HIB-91 of TPI). For specific WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located at 583 D'Onofrio Drive, Madison. Wiscn"-- 53719), Designs Mnrnr A lv.rit JOB PATH: C. ITFF-I.OKION scale = 0.1875 Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: BGE Date: 2-10-00 TIC Live 20.0 psf DurFac - Lbr: 1.15 TIC Dead 10.0 psf DurFac - Pit: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code Desc: TPI 1-1995 TOTAL 40.0 psf V: 1.0' --16 168-156 CENTEX TC FORCE AXL BND CSI 1- 2 -640 0.00 0.66 0.67 2- 3 -130 0.00 0.66 0.66 BC FORCE AXL BND CSI 6- 5 456 0.11 0.27 0.38 5- 4 454 0.11 0.27 0.38 WEB FORCE WEB FORCE 2- 5 176 3- 4 -151 2- 4 -566 RMB = 1.15 j\0 ,E!rA G S TF No. F 16442 STATE OF= INDIANA 07 /ONP& n �rruffu� ,AURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SPF #1/#2 (N) WEBS: 2x4 SPF #3 (N) 2x4 SPF STUD (N) 1 (1: Plate OFFSET from joint center. Refer to Joint Detail Report. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. MAX LIVE LOAD DEFLECTION: L/999 L=-0.01" D=-0.01" T=-0.02" MAX HORIZONTAL DEFLECTION: T= 0.02" WO: ®W1X4 continuous lateral bracing attached with 2- 10d nails each member where shown.Bracing MUST be positioned to provide equal unbraced segments OR 2x4 "T" brace may be nailed flat to edge of web with 12d nails spaced 8" o.c. Brace must extend at least 90% of web length 2x6 Brace required on any web exceeding 141. End vertical(s) not designed for exposure to lateral wind pressure. 9-3-11 0-4-9 �1 2 3 8 00 4X4 2X4 4X6 TI: B "ry:io ==Joint Locations=============== 1) 0- 0- 0 3) 13- 4-11 5) 6-10-11 2) 6-10-11 4) 13- 4-11 6) 0- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1- 0 533 0 0 BOT PIN 13- 3-11 538 0 0 BOT H-ROLL R 11 k____ 13-4-11 k �6 5 4 533# 2.00" 538# 2.00" 13-4-11 -1 EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 T M C wAKNING: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR.BRACING TRUSS MANUFACTURING COMPANY INC. WARNING: Bracing sl usvn on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is a pan of the building design and which must be considered by the building designer. Bracing WESTFI ELD IND 46074 shown is for lateral support of truss members tmly to reduce buckling length. Provisions must he made m anchor lateral bracing at ends and specified Itx ations determined by the building designer. Additional bracing of the overall structure may be required. (See HIB-91 of TPI). For specific WHERE QUALITY COUNTS truss bracing requirements, cunlact building designer. (Truss Plate Institute, TPI, is hwated at 583 D'Onofrio Drive, Madison. Wiscomin 53719), Design: Mmrir Ati.ims JOB PATH.* C.ITF.F,-1.0KIBIN Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: TC Live 20.0 TC Dead 10.0 BC Live 0.0 BC Dead 10.0 TOTAL 40.0 scale = 0.1875 Truss ID: B Date: 2-10-00 psf DurFac - Lbr: 1.15 psf DurFac - Pit: 1.15 psf O.C. Spacing: 24.0" psf Design Criteria: TPI — Code Desc: TPI 1-1995 Ps if V: 1. '-1-160169-157 11r C "I I CEN'I'EX TC FORCE AXL BND CSI BC FORCE AXL BND CSI WEB FORCE AXL BND CSI 36- 2 0 0.00 0.09 0.10 35- 3 0 0.00 0.19 0.19 34- 4 0 0.00 0.32 0.32 33- 6 0 0.00 0.48 0.48 32- 7 0 0.00 0.67 0.67 31- 8 0 0.00 0.90 0.90 30- 9 0 0.00 0.83 0.83 28-10 0 0.00 0.60 0.60 27-11 0 0.00 0.83 0.83 26-12 0 0.00 0.90 0.90 25-13 0 0.00 0.67 0.67 24-14 0 0.00 0.48 0.48 23-16 0 0.00 0.32 0.32 22-17 0 0.00 0.19 0.19 21-18 0 0.00 0.09 0.10 WEB FORCE WEB FORCE RMB = 1.15 •`�p�\0 E. ARC, G STc- No. F 16442 �STE OF= INDIANA /ONNL nIaufu" LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SPF #1/#2 (N) GABLE STUD: 2x3 SPF #3 (N) 2X4 SPF #3 (N) 7,9 2x4 SPF #1/#2 (N) 8 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. Analysis based on Simplified Analog Model. MULTIPLE LOADS -- This design is the composite result of multiple loads. Wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt.=15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. 9-4-9 0-4-9 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c, or a SCAB of the same dimension and grads as web nailed to facets) of web with 10d nails staggered 8" o.c. SCAB or TRANSVERSE BRACING to extend for 80% of web length. 2X6 BRACE req'd on any web exceeding 14, "*" denotes ONE edge or ONE face "**" denotes BOTH edges or BOTH faces [1: Plate OFFSET from joint center. Refer to Joint Detail Report. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise TI: CGE OTY:1 ==============Joint Locations=============== 1) 0- 0- 0 14) 17-10- 8 27) 13-10- 8 2) 3- 2- 8 15) 18- 4-13 28) 12- 6- 8 3) 4- 6- 8 16) 19- 2- 8 29) 12- 0- 0 4) 5-10- 8 17) 20- 6- 8 30) 11- 2- 8 5) 6- 8- 3 18) 21-10- 8 31) 9-10- 8 6) 7- 2- 8 19) 25- 1- 0 32) 8- 6- 8 7) 8- 6- 8 20) 25- 1- 0 33) 7- 2- 8 8) 9-10- 8 21) 21-10- 8 34) 5-10- 8 9) 11- 2- 8 22) 20- 6- 8 35) 4- 6- 8 10) 12- 6- 8 23) 19- 2- 8 36) 3- 2- 8 11) 13-10- 8 24) 17-10- 8 37) 0- 0- 0 12) 15- 2- 8 25) 16- 6- 8 13) 16- 6- 8 26) 15- 2- 8 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 0 0 0 BOT PIN 24-11- 4 0 0 0 BOT H-ROLL 12 - 12- - 1 2 3 4 56 7 8 9 10 11 12 13 14 1516 17 18 1 8 00 -8 00 [5X61 2X4 3X6 4X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 2X4 3X6 8-8-15 0-4-9 4X4 25-1-0 37 36 35 34 33 32 31 30 2928 27 26 25 24 23 22 21 2 0# 3.50" 0k 3.50" 1-0-0 _ �f 25-1-0 11.0.0 (R1-2-7) j EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs @ 1-4-0 o.c. scale = 0.1875 T M C YYFIKIV IIV(i: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR.BRACING TRUSS MANUFACTURING COMPANY INC. WARNING: Bracing shown tin this drawing is not erection bracing, wind bracing, portal bracing t r similar bracing PO BOX 418 which is a pan of the building design and which must he considered by the building designer. Bracing W ESTFI ELD IND 46074 shown is for lateral support of truss members only to reduce buckling length. Provisions must he made to anchor lateral bracing at ends and specified hications determined by the building designer. Additional bracing of the overall structure may be required. (See HIB-91 of TPI). For specific WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is I-aied at 583 D'Onotrio Drive, Madison, Wisconsin 53719). Design: Mnrrir Analvsis JOB PA Tit C. TFF-I,OKIBLV Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: CGE Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - Pit: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code Desc: TPI 1-1995 TOTAL 40.0 psf V 1. ' ^()-160170-158 ors uI CENTEX TIC FORCE AXL BND CSI 1- 2 -1418 0.02 0.49 0.52 2- 3 -1278 0.03 0.50 0.52 3- 4 -1278 0.03 0.50 0.52 4- 5 -1418 0.02 0.49 0.52 BC FORCE AXL BND CSI 10- 9 1099 0.27 0.27 0.54 9- 8 733 0.18 0.27 0.45 8- 7 733 0.18 0.27 0.45 7- 6 1099 0.27 0.27 0.54 WEB FORCE WEB FORCE 2- 9 -341 3- 7 548 3- 9 548 4- 7 -341 RMB = 1.15 01 E . G S Tfi Q No. F 16442 S16TEOF = IN DIANA 10NAL �r�ffnttlt� LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SPF #1/#2 (N) WEBS: 2x4 SPF STUD (N) 2x4 SPF #3 (N) 2,3 MAX LIVE LOAD DEFLECTION: L/999 L=-0.06" D=-0.05" T=-0.11" MAX HORIZONTAL DEFLECTION: T= 0.04" 9-4-9 0-4-9 WO: (I. Plate OFFSET from joint center. Refer to Joint Detail Report. + Denotes 90 degree plate orientation. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise TI: C QTY:10 ==============Joint Locations=============== 1) 0- 0- 0 5) 25- 1- 0 9) 8- 5-14 2) 6- 8-10 6) 25- 1- 0 10) 0- 0- 0 3) 12- 6- 8 7) 16- 7- 2 4) 18- 4- 7 8) 12- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 1063 0 0 BOT PIN 24-11- 4 1003 0 0 BOT H-ROLL 12-6-8 12-6-8 1 2 4 5 11 8 00 OS 0 15X61 8-8-15 0-4-9 n 11 L 25-1-0 1110 9 8 7 6 1063# 3.50" 1003# 3.50" 1100-0 I- 25-1-0 -i � EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 scale = 0.1875 WARNING: READ ALL NOTES ON THIS SHEET. T M C A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING TRUSS MANUFACTURING CONTRACTOR. BRACING WARNING: COMPANY INC. Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is a part of the building design and which must be considered by the building designer. Bracing WESTFI ELD IN D 46074 shown is for lateral support of truss members only it, reduce buckling length. Provisions must be made to anchor lateral bracing at ends and specified Locations determined by the building designer. Additional bracing of the overall structure may he required. (See HIB-91 of TPI). For specific WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute. TPI, is located at 583 D'Onotriu Drive, Madison, Wiscv '1719). Or.ripn: Marti A".1"ir /nR PITH r'77fF 1 n,C'It/%' Eng. Job: Dwg: CENTEX Dsgnr: JR1I Chk: TC Live 20.0 psf TIC Dead 10.0 psf BC Live 0.0 psf BC Dead 10.0 psf TOTAL 40.0 psf WO: Truss ID: C Date: 10-11-00 DurFac - Lbr: 1.15 DurFac - Plt: 1.15 O.C. Spacing: 24.0" Design Criteria: TPI Code Desc: TPI 1-1995 V:01.0 '-306817- 3 CENTEX TC FORCE AXL BND CSI 1- 2 -2605 0.11 0.50 0.61 2- 3 -1838 0.08 0.31 0.40 3- 4 -1838 0.08 0.31 0.40 4- 5 -2605 0.11 0.50 0.61 BC FORCE AXL BND CSI 10- 9 2203 0.53 0.24 0.77 9- 8 2205 0.54 0.14 0.67 8- 7 2205 0.54 0.14 0.67 7- 6 2203 0.53 0.24 0.77 WEB FORCE WEB FORCE 2- 9 98 4- 8 -625 2- 8 -625 4- 7 98 3- 8 1577 RMB = 1.15 \0 G S Tic CF' No. c� STATE OFF INp1ANA = 0 N Pk �. LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) SOT CHORDS: 2x4 SPF #1/#2 (N) WEBS: 2x4 SPF STUD (N) + Denotes 90 degree plate orientation MAX LIVE LOAD DEFLECTION: L/999 L=-0.17" D=-0.17" T=-0.34" MAX HORIZONTAL DEFLECTION: T= 0.32" 9-4-9 0-4-9 T- WO: Recoamtend the use of SIMPSON 1TC241 hanger at one support. (]: Plate OFFSET from joint center. Refer to Joint Detail Report. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. TI: CC QTY:5 ==============Joint Locations=============== 1) 0- 0- 0 5) 25- 1- 0 9) 6- 6- 8 2) 6- 6- 8 6) 25- 1- 0 10) 0- 0- 0 3) 12- 6- 8 7) 18- 6- 8 4) 18- 6- 8 8) 12- 6- 8 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 1003 0 0 SOT PIN 24-11- 4 1063 0 0 BOT H-ROLL 12-6-8 12 -8 Ilk 1 2 4 5 8 00 -8 00 [5X61 8-8-15 0-4-9 Imo- 6-6-0 - 0 4.00 I 14.00 0-3-8 _I � 0-3-8 12-3-0 12-3-0 0 9 7 1003# 3.50" 1063# 3.50" 25-1-0 �1--0-00 COSMETIC PLATES (4) 2X4 (I R1-2-7) EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 scale = 0.1875 T M C WAKNINki: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR.BRACING TRUSS MANUFACTURING COMPANY INC. WARNING: Bracing shown "n this drawing is not erection bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is apart of the building design and which must be considered by the building designer. Bracing WESTFI ELD IND 46074 shown is for lateral support of truss members only to reduce buckling length. Provisions must be made w anchor lateral bracing at ends and specified locations determined by the building designer. Additional bracing of the overall structure may he required. (See IIIB-91 of TPI). For specific WHERE QUALITY COUNTS trues bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located at 583 D'Onofrio Drive, Madison, Wisconsin 53719). Design: Malrir Analysis JOB PATH: C:ITFF-LOKIBIN Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: CC Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - Plt: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code Desc: TPI 1-1995 TOTAL 40.0 psf V: 1.01 "r1-160171-159 ll("S M t. CENTEX I LAURENS MODEL 1018 TC FORCE AXL BND CSI TOP CHORDS: 2x4 SPF #1/#2 (N) 1- 2 -2605 0.11 0.50 0.61 BOT CHORDS: 2x4 SPF #1/#2 (N) 2- 3 -1838 0.08 0.31 0.40 WEBS: 2x4 SPF STUD (N) 3- 4 -1838 0.08 0.31 0.40 + Denotes 90 degree plate orientation. 4- 5 -2605 0.11 0.50 0.61 MAX LIVE LOAD DEFLECTION: L/999 BC FORCE AXL BND CSI L=-0.17" D=-0.17" T=-0.34" 10- 9 2203 0.53 0.24 0.77 MAX HORIZONTAL DEFLECTION: 9- 8 2205 0.54 0.14 0.67 T= 0.32" 8- 7 2205 0.54 0.14 0.67 7- 6 2203 0.53 0.24 0.77 WEB FORCE WEB FORCE 2- 9 98 4- 8 -625 2- 8 -625 4- 7 98 3- 8 1577 RMB = 1.15 , %%,%I I I1111j1 Q. No, F 16442 STATE OFF INDIANA �4ZT ADO �'''FSS�OfVAL ��•�`• /� �--�l-l�lll-111111 9-4-9 0-4-9 WO: Recommend the use of SIMPSON 'TC24' hanger at one support. [1: Plate OFFSET from joint center. Refer to Joint Detail Report. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise TI: CC1 QTY:1 -----------===Joint Locations=============== 1) 0- 0- 0 5) 25- 1- 0 9) 6- 6- 8 2) 6- 6- 8 6) 25- 1- 0 10) 0- 0- 0 3) 12- 6- 8 7) 18- 6- 8 4) 18- 6- 8 8) 12- 6- 8 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 1003 0 0 BOT PIN 24-11- 4 1063 0 0 BOT H-ROLL 12- - 12-6-8 1 2 4 5 8 00 -8 0000 la-- 7-10-0 11.I [5X61 I 8-8-15 0-4-9 4.00 1--4.00 0-3-8 �� 12-3-0 12-3-0 0 9 7 1003# 3.50" 1063# 3.50" iG 25-1-0 1 100 COSMETIC PLATES (4) 2X4 EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 scale = 0.1875 T M C WAKNIN(i: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING TRUSS MANUFACTURING COMPANY INC. PO BOX 418 W ESTFI ELD I N D 46074 WHERE QUALITY COUNTS CONTRACTOR. BRACING WARNING: Bracing sh"wn on this drawing is not crection bracing, wind bracing. Portal bracing or similar bracing which is a Pan of the building design and which must he considered by the building designer. Bracing shown is liarlateral support of truss members only to reduce buckling length. Provisions must he made m anchor lateral bracing at ends and specified Imatiuns determined by the building designer. Additional bracing of the overall structure may he required. (See HID-91 "f TPI). For spccilic truss bracing requirements, contact building designer, (Truss Plate Institute, TPI, is (mated at 583 D'Onufriu Drive, Madison. Wiscun•;- 53719). Drsi,V M"rrir Annlesis JOB PATH: CIT/i/i-I.(Wilt/N Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: TC Live 20.0 TC Dead 10.0 BC Live 0.0 BC Dead 10.0 TOTAL 40.0 WO: Truss ID: CC1 Date: 2-10-00 psf DurFac - Lbr: 1.15 psf DurFac - Pit: 1.15 psf O.C. Spacing: 24.0" psf Design Criteria: TPI - Code Desc: TPI 1-1995 PSr V:01.0' "1-160172-160 IW( Ill " CEN I EX TC FORCE AXL BND CSI 1- 2 -2605 0.11 0.50 0.61 2- 3 -1838 0.08 0.31 0.40 3- 4 -1838 0.08 0.31 0.40 4- 5 -2605 0.11 0.50 0.61 BC FORCE AXL BND CSI 10- 9 2203 0.53 0.24 0.77 9- 8 2205 0.54 0.14 0.67 8- 7 2205 0.54 0.14 0.67 7- 6 2203 0.53 0.24 0.77 WEB FORCE WEB FORCE 2- 9 98 4- 8 -625 2- B -625 4- 7 98 3- 8 1577 RMB = 1.15 %% o , E �I A,Q'• c' No, c� 16442 STATE OF= =fir INDIAN O /ONAL �nf�+ �a LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SPF #1/#2 (N) WEBS: 2x4 SPF STUD (N) + Denotes 90 degree plate orientation MAX LIVE LOAD DEFLECTION: L/999 L=-0.17" D=-0.17" T=-0.34" MAX HORIZONTAL DEFLECTION: T= 0.32" 9-4-9 0-4-9 WO: Recommend the use of SIMPSON 'TC24' hanger at one support. [1: Plate OFFSET from joint center. Refer to Joint Detail Report. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. T1: CC2 QTY:1 =_---=========Joint Locations=============== 1) 0- 0- 0 5) 25- 1- 0 9) 6- 6- 8 2) 6- 6- 8 6) 25- 1- 0 10) 0- 0- 0 3) 12- 6- 8 7) 18- 6- 8 4) 18- 6- 8 8) 12- 6- 8 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 1003 0 0 BOT PIN 24-11- 4 1063 0 0 BOT H-ROLL 12-6-8 12-6-8 1 2 4 5 8 00 -8 0000 [5X6] {� 9-10-0 - 8-8-15 0-4-9 4.00 -4.00 0-3-8 �� 12-3-0 12-3-0 0 9 7 1003# 3.50" 1063# 3.50" L- 25-1-0 1-0-0-0 COSMETIC PLATES (8) 2X4 r (' R1-Z-7) EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 scale = 0.1875 T M C TRUSS MANUFACTURING COMPANY INC. PO BOX 418 WESTFIELD IND 46074 WHERE QUALITY COUNTS Desgn: Matriv Annh•sis WAKNINU: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR. BRACING WARNING: Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing which is a pan of the building design and which must he considered by the building designer. Bracing shown is for lateral support of truss members only ht reduce buckling length. Provisions must he made to anchor lateral bracing at ends and specified locations determined by the building designer. Additional bracing of the overall structure may he required. (See HIB-91 of TPI). For specific truss bracing requirements, contact building designer. (Truss Plate Institute. TPI, is located at 583 D'Onotrio Drive, Madison, Wisconsin 53719). JOB PATH: C. ITEE-I,OKIBIA' Eng. Job: Dwg: CENTER Dsgnr: JRH Chk: WO: Truss ID: CC2 Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - PIt: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code Desc: TPI 1-1995 TOTAL 40.0 psf V: 1. 1 I10U2173-161 'W's M !. CEN1'EX I LAURENS MODEL 1018 TC FORCE AXL BND CSI TOP CHORDS: 2x4 SPF #1/#2 (N) 1- 2 -2605 0.11 0.50 0.61 BOT CHORDS: 2x4 SPF #1/#2 (N) 2- 3 -1838 0.08 0.31 0.40 WEBS: 2x4 SPF STUD (N) 3- 4 -1838 0.08 0.31 0.40 + Denotes 90 degree plate orientation 4- 5 -2605 0.11 0.50 0.61 MAX LIVE LOAD DEFLECTION: L/999 BC FORCE AXL BND CSI L=-0.17" D=-0.17" T=-0.34" 10- 9 2203 0.53 0.24 0.77 MAX HORIZONTAL DEFLECTION: 9- 8 2205 0.54 0.14 0.67 T= 0.32" 8- 7 2205 0.54 0.14 0.67 7- 6 2203 0.53 0.24 0.77 WEB FORCE WEB FORCE 2- 9 98 4- 8 -625 2- 8 -625 4- 7 98 3- 8 1577 RMB = 1.15 `,,`��SN n1�rJrIr�I 0 E. G STE- No. F 16442 SrArE OF INDIANA 10 £sS/0 N AL r'rr�rtltlttL 9-4-9 0-4-9 WO: Recommend the use of SIMPSON 'TC24' hanger at one support. 0: Plate OFFSET from joint center. Refer to Joint Detail Report. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise TI: CC3 QTV:3 ==============Joint Locations=============== 1) 0- 0- 0 5) 25- 1- 0 9) 6- 6- 8 2) 6- 6- 8 6) 25- 1- 0 10) 0- 0- 0 3) 12- 6- 8 7) 18- 6- 8 4) 18- 6- 8 8) 12- 6- 8 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 1003 0 0 BOT PIN 24-11- 4 1063 0 0 BOT H-ROLL 12-6-8 12- - 1 2 4 5 8 00 -8 00 r 10-4-0 - - f5X61 0-4-9 8-8-15 4.001 14.00 0-3-8 12-3-0 12-3-0 0 9 7 1003# 3.50" 1063# 3.50" L 25-1-0 -� 1� 0-0 COSMETIC PLATES (8) 2X4 r (RI-2-7) EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 scale = 0.1875 T M C VVAKIVIIVCi: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR.BRACING TRUSS MANUFACTURING COMPANY INC. WARNING: Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is a part of the building design and which must be considered by the building designer. Bracing W ESTFI ELD IND 46074 shown is for lateral support of truss members only to reduce buckling length. Provisions must be made to anchor lateral bracing w ends and specified locations determined by the building designer. Additional bracing of the overall structure may be required. (See HIB-91 of TPI). For specific WHERE QLIALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute. TPI, is located at 583 D'Onofrio Drive, Madison, W iscon6n 53719). Drsign: A-famr Analysis JOB PATH: C'ITFF-LOKIRIN Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: CC3 Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - Plt: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code Desc: TPI 1-1995 TOTAL 40.0 psf V:01 0l "1-160174-162 Hcc 01 t U N1EX TC FORCE AXL BND CSI BC FORCE AXL BND CSI WEB FORCE AXL BND CSI 9- 2 0 0.00 0.04 0.04 8- 3 0 0.00 0.11 0.11 7- 4 0 0.00 0.22 0.22 6- 5 0 0.00 0.36 0.36 WEB FORCE WEB FORCE RMB = 1.15 r G STF No. F 16442 _ STATE OF= INDIAN IONAL LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SPF #1/#2 (N) WEBS: 2x3 SPF #3 (N) GABLE STUD: 2x3 SPF #3 (N) All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. Wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt.=15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. M03 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. Analysis based on Simplified Analog Model. MULTIPLE LOADS -- This design is the composite result of multiple loads. End vertical(s) not designed for exposure to lateral wind pressure. L 6-3-11 L �1 2 �4 51 0 T 3X4 2X4 2X4 2X4 2X4 TI: DGE QTY:1 ==============Joint Locations=============== 1) 0- 0- 0 5) 6- 3-11 9) 2- 1-15 2) 2- 1-15 6) 6- 3-11 10) 0- 0- 0 3) 3- 5-15 7) 4- 9-15 4) 4- 9-15 8) 3- 5-15 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 0 0 0 BOT PIN 6- 1-15 0 0 0 BOT H-ROLL 4-7-1 1'16-3-11 T 1 10 9 8 7 6 0# 3.50" 0# 3.50" in 6-3-11 EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs ® 1-4-0 ox T M C WAKNINti: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR. TRUSS MANUFACTURING COMPANY INC. BRACING WARNING. Bracing shown on this drawing is not •:en bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is a part of the building design which must he considered by the building designer. Bracing WESTFI ELD IND 46074 shown is for lateral support of truss r. -rs only to reduce buckling length. Provisions must he made In anchor lateral bracing at cnd� , specified 1—tions determined by the building designer. Additional bracing of the overall structure may he required. (See HIB-91 of TPI). For specific WHERE QUALITY COUNTS truss bracing requirements, contact budding designer. (Truss Plate Institute, TPI, is located at 583 D'Onofrio Drive, Madison, Wisconsin 53719). Design: Mmrir .lnalvsis JOB PATH. C ITF.F_-LOKIRIN scale = 0.3750 Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: DGE Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - Plt: 1.15 BC Live 0.0 psi O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code Desc: TPI 1-1995 TOTAL 40.0 psf V: 1 01 0o-160175-163 I K-.P 01 CENTEX TC FORCE AXL BND CSI BC FORCE AXL BND CSI WEB FORCE AXL BND CSI 30- 2 0 0.00 0.10 0.10 29- 3 0 0.00 0.23 0.23 28- 4 0 0.00 0.41 0.41 27- 5 0 0.00 0.64 0.64 26- 6 0 0.00 0.92 0.92 25- 7 0 0.00 0.89 0.89 23- 8 0 0.00 0.68 0.68 22- 9 0 0.00 0.89 0.89 21-10 0 0.00 0.92 0.92 20-11 0 0.00 0.64 0.64 19-12 0 0.00 0.41 0.41 18-13 0 0.00 0.23 0.23 17-14 0 0.00 0.10 0.10 WEB FORCE WEB FORCE RMB = 1.15 �pN\01 E'+ A1Rc •� GNo. f F 16442 STgTE OF = INDIAN4 •, 0/" FSS/0 N AL /� 1j1j11/111111 LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SPF #1/#2 (N) GABLE STUD: 2x3 SPF #3 (N) 2x4 SPF #3 (N) 6,8 2x4 SPF #1/#2 (N) 7 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. Analysis based on Simplified Analog Model. MULTIPLELOADS -- This design is the composite result of multiple loads. Wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt.=15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. 9-11-9 0-6-9 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. or a SCAB of the same dimension and grade as web nailed to facets) of web with 10d nails staggered 8" o.c. SCAB or TRANSVERSE BRACING to extend for 80% of web length. 2X6 BRACE req'd on any web exceeding 14' denotes ONE edge or ONE face denotes BOTH edges or BOTH faces 11: Plate OFFSET from joint center. Refer to Joint Detail Report. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise TI: EGE TY:I ========== ==Joint Locations======__======= 1) 0- 0 0 12) 15-10- 0 23) 10- 6- 0 2) 2- 6- 0 13) 17- 2- 0 24) 10- 0- 0 3) 3-10- 0 14) 18- 6- 0 25) 9- 2- 0 4) 5- 2- 0 15) 21- 0- 0 26) 7-10- 0 5) 6- 6- 0 16) 21- 0- 0 27) 6- 6- 0 6) 7-10- 0 17) 18- 6- 0 28) 5- 2- 0 7) 9- 2- 0 18) 17- 2- 0 29) 3-10- 0 8) 10- 6- 0 19) 15-10- 0 30) 2- 6- 0 9) 11-10- 0 20) 14- 6- 0 31) 0- 0- 0 10) 13- 2- 0 21) 13- 2- 0 11) 14- 6- 0 22) 11-10- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 0 0 0 BOT PIN 20-10- 4 0 0 0 BOT H-ROLL 10-6-0 10-6-0 Ilk 1 2 3 4 5 6 7 9 10 11 12 13 14 I 1 00 0 -I0 00 [4X61 [.)AD] 3X6 [3X61 2 9-3-9 0-6-9 '31 30 29 28 27 26 224 23 22 21 N 19 18 17 id 0# 3.50" 0# 3.50" 100 le 21-0-0 _1 1� 0-0 (R1-3-10) j I (R1-3-10) EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs ® 1-4-0 o.c. scale = 0.1875 T M C WAKNINU: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR.BRACING TRUSS MANUFACTURING COMPANY INC. WARNING: Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is a pan of the building design and which must he considered by the building designer. Bracing WESTFIELD IND 46074 shown is for lateral support of truss members only to reduce buckling length. Provisions must he made to anchor lateral bracing at ends and specified locations determined by the building designer. W H ERE QUALITY COUNTS Additional bracing of the overall structure may be required. (See 1-1I13-91 of TPI). For specific truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located al S83 D'Onufno Drive, Madison. Wiw,-;; 53719). Design: Mmro .4nnlesi.s JOB PATH: C: I TE6--LOKIflIN Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: EGE Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - Pit: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code Desc: TPI 1-1995 TOTAL 40.0 psf V:01.0'-()-160176-164 llf C- nl I, GIN L t'A I TC FORCE AXL BND CSI 1- 2 -1058 0.01 0.32 0.33 2- 3 -950 0.01 0.32 0.34 3- 4 -950 0.01 0.32 0.34 4- 5 -1058 0.01 0.32 0.33 BC FORCE AXL BND CSI 10- 9 741 0.18 0.18 0.36 9- 8 493 0.12 0.18 0.30 8- 7 493 0.12 0.18 0.30 7- 6 741 0.18 0.18 0.36 WEB FORCE WEB FORCE 2- 9 -266 3- 7 423 3- 9 423 4- 7 -266 RMB = 1.15 \O E. ' 9- s F' No,. F 16442 srgrE of 1NDIANA F /O N AL ��•�`, LAUKLNJ MOVEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SPF #1/#2 (N) WEBS: 2x3 SPF #3 (N) 2x4 SPF #3 (N) 2,3 MAX LIVE LOAD DEFLECTION: L/999 L=-0.04" D=-0.04" T=-0.08" MAX HORIZONTAL DEFLECTION: T= 0.03" 9-11-9 0-6-9 [I: Plate OFFSET from joint center. Refer to Joint Detail Report. + Denotes 90 degree plate orientation. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise TI: E QTY:3 ======--======Joint Locations=============== 1) 0- 0- 0 5) 21- 0- 0 9) 7- 0-10 2) 5- 3-14 6) 21- 0- 0 10) 0- 0- 0 3) 10- 6- 0 7) 13-11- 6 4) 15- 8- 2 8) 10- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 898 0 0 BOT PIN 20-10- 4 898 0 0 BOT H-ROLL 10-6-0 10-6-0 Ik Ilk 1 2 4 5 10 00 -10 00 [5X61 WAD] [3X6) 9-3-9 0-6-9 n n 21-0-0 10 9 8 7 6 898# 3.50" 898# 3.50" 1-0-0 L 21-0-0 �� 100 (RI-3- o r (I` R1=3-i0) EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 scale = 0.1875 T M C TRUSS MANUFACTURING COMPANY INC. WARNING: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR. BRACING WARNING: Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: E Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing TC Dead 10.0 psf DurFae - Plt: 1.15 PO BOX 418 WESTFIELD IND 46074 which is a pan of the building design and which must be considered by the building designer. Bracing shown is for lateral support of truss members only it) reduce buckling length. Provisions must he BC Live 0.0 psf O.C.Spacing: 24.0" P g made to anchor lateral bracing at ends and specified fixations determined by the building designer. Additional bracing of the overall structure maybe required. (See NIB-91 of TPI). For specific $C Dead . I00 f PSI` Design Criteria: TPI WHERE QUALITY COUNTS tors bracing requirements, contact building designer. (Truss Plate Institute, TPI, is fixated at Dese: TPI 1-1995 iv 583 D'OnofrioDre, Madison, Wiv:unsin53719). TOTAL 40.0 psf V• 0 1, 01.()0-160177-165 Design: Marrir Analysis JOB PATH: C:ITEE-LOKIBIN HCS 0l U N FEX TC FORCE AXL BND CSI 1- 2 -3624 0.29 0.26 0.55 2- 3 -3608 0.31 0.32 0.63 3- 4 -3608 0.31 0.32 0.63 4- 5 -3624 0.29 0.26 0.55 BC FORCE AXL BND CSI 11-10 2708 0.15 0.27 0.42 10- 9 1884 0.10 0.35 0.45 9- 8 1884 0.10 0.35 0.45 8- 7 1884 0.10 0.17 0.28 7- 6 2708 0.15 0.27 0.42 WEB FORCE WEB FORCE 2-10 -267 3- 7 1642 3-10 1642 4- 7 -267 3- 9 1328 RMB = 1.00 \0 E. F '�cF•, No,. c" 16442 STATE OF= =fir INDIAN O,r ���''� FSS10 N Al E�.�`• LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x6 SP MEL-23 WEBS: 2x4 SPF #3 (N) 2x4 SPF #1/#2 (N) 2,4 WEDGES: 2x4 SPF #1/#2 (N) This 1-PLY truss designed to carry 13' 4" span framed to BC one face 21 0" span split -framed to opposite face MAX LIVE LOAD DEFLECTION: L/999 L=-0.11" D=-0.11" T=-0.21" MAX HORIZONTAL DEFLECTION: T- 0.10" 9-3-9 0-6-9 WO: Top Chord MUST be continuously laterally braced (BY OTHERS) to resist buckling PERPENDICULAR to the plane of the truss. 0: Plate OFFSET from joint center. Refer to Joint Detail Report. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. TI: EGR QTY:1 ==============Joint Locations=============== 1) 0- 0- 0 5) 21- 0- 0 9) 10- 6- 0 2) 5- 5- 2 6) 21- 0- 0 10) 5- 5- 2 3) 10- 6- 0 7) 15- 6-14 11) 0- 0- 0 4) 15- 6-14 8) 14- 0- 0 ------------ TOTAL DESIGN LOADS ------------ Uniform PLF From PLF To TC Vert L+D -60 0- 0- 0 -60 21- 0- 0 BC Vert L+D -242 0- 0- 0 -242 21- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-14 3171 0 0 BOT PIN 20-10- 2 3171 0 0 BOT H-ROLL 10-6-0 10-6-0 Ilk 1 2 4 5 10 00 -10 00 [7X 101 [8X81 [8X81 [3X8] 5X8[8X81 [8X8] 0-6-9 I� 21-0-0 �11 10 9 8 7 - 3172# 3.75" 3172# 3.75" 21-0-0 _1 EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 T M C WARNING: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING TRUSS MANUFACTURING CONTRACTOR.BRACING WARNING: COMPANY INC. Bracing shown tin this drawing is not erection bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is a part of the building design and which must he considered by the building designer. Bracing W ESTFI ELD IND 46074 shown is for lateral support of truss members only to reduce buckling length. Provisions must be made m anchor lateral bracing at ends and specified locations determined by the building designer. Additional bracing of the overall structure may he required. (See HIB-91 tit TPI). For specific WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located at 583 D'Onofrio Drive. Madison, Wiwonsin 53719). Design: Matrix Analvsis JOB PATH. CATF-F_-LOXIB/N 9-3-9 scale = 0.1875 Eng. Job: WO: Dwg: CENTEX Truss ID: EGR Dsgnr: JRH Chk: Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - Plt: 1.15 BC Live 0.0 psi O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code Desc: TPI 1-1995 TOTAL 40.0 psf V:01. 1 A0-160178-166 fICS 01 t CENTEX TC FORCE AXL END CSI 1- 2 -1058 0.01 0.32 0.33 2- 3 -950 0.01 0.32 0.34 3- 4 -950 0.01 0.32 0.34 4- 5 -1058 0.01 0.32 0.33 BC FORCE AXL BND CSI 10- 9 741 0.18 0.18 0.36 9- 8 493 0.12 0.18 0.30 8- 7 493 0.12 0.18 0.30 7- 6 741 0.18 0.18 0.36 WEB FORCE WEB FORCE 2- 9 -266 3- 7 423 3- 9 423 4- 7 -266 RMB = 1.15 0 E. AR•,,�� S 16442 STgTE OF 04D1ANA = oFFSs10 N AL ���� ` n -utttt� LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SPF #1/#2 (N) WEBS: 2x3 SPF #3 (N) 2x4 SPF #3 (N) 2,3 GABLE STUD: 2x3 SPF #3 (N) 2x3 SPF #3 (N) 5, 7, 10, 12 2x3 SPF #3 (N) 6,8,11,13 2x3 SPF #1/#2 (N) 9 MAX LIVE LOAD DEFLECTION: L/999 L=-0.04" D=-0.04" T=-0.08" MAX HORIZONTAL DEFLECTION: T= 0.03" 9-11-9 0-6-9 WO: 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. [1: Plate OFFSET from joint center. Refer to Joint Detail Report. + Denotes 90 degree plate orientation. MULTIPLE LOADS -- This design is the composite result of multiple loads. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. T1: ESC QTY:I ======_=-=====Joint Locations=============== 1) 0- 0- 0 5) 21- 0- 0 9) 7- 0-10 2) 5- 3-14 6) 21- 0- 0 10) 0- 0- 0 3) 10- 6- 0 7) 13-11- 6 4) 15- 8- 2 8) 10- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 898 0 0 BOT PIN 20-10- 4 898 0 0 BOT H-ROLL Wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt -15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. 10-6-0 10-6-0 1 2 4 5 10 00 -1-0.-0 [5X61 9-3-9 0-6-9 [3X61 [3X61 6 '10 9 8 7 898# 3.50" 1-0-0 iq 21-0-0 GABLE STUD PLATES (6T3 40) r EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 T M C WARNING: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR. TRUSS MANUFACTURING BRACING WARNING: COMPANY INC. Bracing shown tin this Drawing is not erection bracing, wind bracing, Portal bracing or similar bracing PO BOX 418 which is a Part "f the building design and which must he considered by the building designer. Bracing shown is for lateral support of truss members only tit reduce buckling length. Provisions must he W ESTFI ELD IND 46074 made to anchor lateral bracing at ends and specified locations determined by the building designer. Additional bracing "f the overall structure maybe required. (See HIB-91 of TPI). Fur specilic WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is b><ated at 583 D'Onofriu Drive, Madison, Wi.scv 1719), inn t• rrrt r i-ry t nr xn M 898# 3.50" 100 (R1-3-10) Studs a 1-4-0 o.c. Eng. Job: DWg: CENTEX Dsgnr: JRH Chk: TC Live 20.0 psf TC Dead 10.0 psf BC Live 0.0 psf BC Dead 10.0 psf TOTAL 40.0 psf scale = 0.1875 Truss ID: ESC Date: 10-11-00 DurFac - Lbr: 1.15 DurFac - Plt: 1.15 O.C. Spacing: 24.0" Design Criteria: TPI Code Desc: TPI 1-1995 CENTEX I LAURENS MODEL 1018 TC FORCE AU BND CSI TOP CHORDS: 2x4 SPF #1/#2 (N) 1- 2 -76 0.00 0.24 0.24 BOT CHORDS: 2x4 SPF #1/#2 (N) 2- 3 -171 0.00 0.24 0.24 WEBS: 2x3 SPF #3 (N) 3- 4 -171 0.00 0.24 0.24 GABLE STUD: 2x3 SPF #3 (N) 4- 5 -76 0.00 0.24 0.24 MULTIPLE LOADS -- This design is the composite result of multiple loads. BC FORCE AXL BND CSI MAX LIVE LOAD DEFLECTION: 10- 9 68 0.02 0.22'0.24 L/999 9- 8 68 0.02 0.22 0.24 L=-0.02" D=-0.02" T=-0.03" 8- 7 68 0.02 0.22 0.24 MAX HORIZONTAL DEFLECTION: 7- 6 68 0.02 0.22 0.24 T= 0.03" WEB FORCE WEB FORCE 2- 9 -238 4- 7 -238 3- 8 35 RMB = 1.15 S'r No. F 16442 STATE OF� = 11V p1ANA T""FS'SIO N AL � 0% �rrrruntt� 1 -9-0 GABLE STUD PLATES EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 T M C WARNING: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR.BRACING TRUSS MANUFACTURING COMPANY INC. WARNING: PO BOX 418 Bracing shown on this drawing is not erection bracing, wind bracing, Portal bracing or similar bracing which is a Part of the building design and which must he considered by the building designer. Bracing WESTFIELD IND 46074 shown is for lateral support of truss members only la reduce buckling length. Provisions must he lateral made to anchor bracing at ends and specified locations determined by the building designer. Additional bracing of the overall structure may he required. (See HIB-91 of TPI). For specific WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute. TP), is boated at 583 D'Onufriu Drive. Madison. W iwonsin 53719). Oesign: Mrrrrir AwNsis JOR PATH: CITEE-I.OKIRIN 5-3-5 0-6-9 4 -- 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. 0. Plate OFFSET from joint center. Refer to Joint Detail Report. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. Wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt.=15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. TI: FGE QTY:1 =====___======Joint Locations=============== 1) 0- 0- 0 5) 9- 9- 0 9) 1- 6-12 2) 1- 6-12 6) 9- 9- 0 10) 0- 0- 0 3) 4-10- 8 7) 8- 2- 4 4) 8- 2- 4 8) 4-10- 8 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 1- 6-12 450 -14 0 BOT PIN 8- 2- 4 450 0 0 BOT H-ROLL 4-10-8 4-10-8 1 2 4 5 10 00 5X4 10.00 M L _ 9-9-0 110 9 8 7, 61 CANTI: 1-5-0 450N 3.50" 450# 3.50" CANT: 1-5-0 100 (R1-3-10) Studs a 14-0 o.c. 0-6-9 4-7-5 Eng. Job: Dwg: CENTEX Dsgnr. JRH Chk: TC Live 20.0 TC Dead 10.0 BC Live 0.0 BC Dead 10.0 TOTAL 40.0 scale = 0.3750 WO: Truss ID: FGE Date: 2-10-00 psf DurFac - Lbr: 1.15 psf DurFac - Pit: 1.15 psf O.C. Spacing: 24.0" Psi` Design Criteria: TPI - Code Desc: TPI 1-1995 psf V: 1. 1 ^')-160179-167 i HCC nI t CENTEX TC FORCE AXL BND CSI 1- 2 -76 0.00 0.24 0.24 2- 3 -171 0.00 0.24 0.24 3- 4 -171 0.00 0.24 0.24 4- 5 -76 0.00 0.24 0.24 BC FORCE AXL BND CSI 10- 9 68 0.02 0.22 0.24 9- 8 68 0.02 0.22 0.24 8- 7 68 0.02 0.22 0.24 7- 6 68 0.02 0.22 0.24 WEB FORCE WEB FORCE 2- 9 -238 4- 7 -238 3- 8 35 RMB = 1.15 G S TF No. F 16442 STATE OF IND)ANA ��'�FFSSIO N AL �f)m1111t , LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SPF #1/#2 (N) WEBS: 2x3 SPF #3 (N) All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. MAX LIVE LOAD DEFLECTION: L/999 L=-0.02" D--0.02" T=-0.03" MAX HORIZONTAL DEFLECTION: T= 0.03" 5-3-5 0-6-9 4 WO: [1: Plate OFFSET from joint center. Refer to Joint Detail Report. MULTIPLE LOADS -- This design is the composite result of multiple loads. Wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt.=15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. TI: F QTY:I __========= ==Joint Locations=============== 1) 0- 0- 0 5) 9- 9- 0 9) 1- 6-12 2) 1- 6-12 6) 9- 9- 0 10) 0- 0- 0 3) 4-10- 8 7) 8- 2- 4 4) 8- 2- 4 8) 4-10- 8 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 1- 6-12 450 -14 0 BOT PIN 8- 2- 4 450 0 0 BOT H-ROLL 4-10-8 4-10-8 Ilk 1 2 4 5 M 10 00 5X4 9-9-0 -10 00 M 0-6-9 4-7-5 '10 9 8 7 61 CANT: 1-5-0 450# 3.50" 450N 3.50" CANT: 1-5-0 1�0 00) 9-9-0 1.0.0 (R1-3-10) I I� �-(-R1--3--10) EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TP1 1-1995 scale = 0.3750 T M C YY'P►KNINU: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING TRUSS MANUFACTURING CONTRACTOR.BRACING WARNING: COMPANY INC. Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is apart of the building design and which must he considered by the building designer. Bracing WESTFIELD IND 46074 shown is for lateral support of truss members only to reduce buckling length. Provisions must he made to anchor lateral bracing at ends and specified locations determined by the building designer. Additional bracing of the overall structure may he required. (See HIB-91 of TPI). For specific WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located at 583 D'Onufriu Drive, Madison, W iscun•'- 53719). Deign: Maim Annlvlis JOB PATH: C.ITEE-I,OKIBIN Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: F Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - Pit: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code De--: TPI 1-1995 TOTAL 40.0 psf I V:01. i 160180-168 11CF 01 01 /XI UEN'1 EX TC FORCE AXL BND CSI 1- 2 241 0.03 0.06 0.09 2- 3 -1937 0.01 0.07 0.08 3- 4 -1918 0.02 0.11 0.13 4- 5 -3133 0.04 0.10 0.14 BC FORCE AXL BND CSI 10- 9 -150 0.00 0.19 0.19 9- 8 -55 0.00 0.19 0.19 8- 7 2278 0.06 0.20 0.26 7- 6 2329 0.06 0.03 0.10 WEB FORCE WEB FORCE 2- 9 -2179 4- 8 -918 2- 8 1647 4- 7 1158 3- 8 2170 RMB = 1.00 \0 E. qR'•.. No. F 16442 S7gTE OF= car INDIANA O /0 N AL � 0 �} ���uuflfll .AURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x6 SP MEL-23 WEBS: 2x4 SPF #3 (N) 2x4 SPF STUD (N) 1,5 WEDGES: 2x4 SPF #1/#2 (N) All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. 2-PLY TRUSSI fasten w/10d nails in staggered pattern per nailing schedule: TC- 2 per ft. BC- 2 per ft. WEBS- 2 per ft Distribute loads equally to each ply. MAX LIVE LOAD DEFLECTION: L/999 L=-0.01" D=-0.01" T=-0.03" MAX HORIZONTAL DEFLECTION: T= 0.01" T 4-7-5 0-6-9 Top Chord MUST be continuously laterally braced (BY OTHERS) to resist buckling PERPENDICULAR to the plane of the truss. [1: Plate OFFSET from joint center. Refer to Joint Detail Report. + Denotes 90 degree plate orientation. This 2-PLY truss designed to carry 36' 2" span framed to BC one face 21 0" span split -framed to opposite face Tl: FGR QTY:2 ==============Joint Locations=============== 1) 0- 0- 0 5) 9- 9- 0 9) 1- 6-12 2) 1- 6-12 6) 9- 9- 0 10) 0- 0- 0 3) 4-10- 8 7) 8- 2- 4 4) 8- 2- 4 8) 4-10- 8 ------------ TOTAL DESIGN LOADS ------------ Uniform PLF From PLF To TC Vert L+D -60 0- 0- 0 -60 9- 9- 0 BC Vert L+D -697 0- 0- 0 -697 9- 9- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 1- 6-12 4343 0 0 BOT PIN 9- 7- 4 3042 0 0 BOT H-ROLL 2-PLYS REQUIRED 4-10-8 4-10-8 1 2 4 5 10 00 [6X6) [6X6] 3X6 [7X16I 10 00 1 4-7-5 0-6-9 3X6 [6X6] 9-9-0 I, �10 9 8 7 6 CANT: 1-5-0 4343# 3.50" 3042t1 3.50" 9-9-0 -i. EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 T M C WARNING: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING TRUSS MANUFACTURING COMPANY INC. PO BOX 418 WESTFIELD IND 46074 WHERE QUALITY COUNTS CONTRACTOR.BRACING WARNING: Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing which is a part of the building design and which must he considered by the building designer. Bracing shown is for lateral support of truss members only to reduce buckling length. Pruvisiuns must he made to anchor lateral bracing at ends and specified locations determined by the building designer. Additional bracing of the overall structure may he required. (See HIS-91 ol'TPI). For specific truss bracing requirements, contact building designer. (Truss Plate Institute. TPI, is located al 583 D'Onofrio Drive, Madison, Wisconsin 53719). Design: Mairiv AnaNsis JOB PATH,- C ITEE-LOKIRIN scale = 0.3750 Eng. Job: WO: Dwg: CENTEX Truss ID: FGR Dsgnr: JRH Chk: Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - Plt: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code Desc: TPI 1-1995 TOTAL 40.0 psf V: 1 - 160181-169 11CC 01 01 - CENTEX TC FORCE AXL BND CSI 1- 2 -2135 0.21 0.75 0.96 2- 3 -1935 0.06 0.84 0.91 3- 4 -2175 0.07 0.32 0.39 4- 5 -4011 0.17 0.39 0.56 5- 6 -3495 0.19 0.47 0.66 BC FORCE AXL BND CSI 12-11 1678 0.34 0.44 0.78 11-10 1185 0.24 0.44 0.68 10- 9 1185 0.24 0.26 0.50 9- 8 2113 0.42 0.26 0.69 8- 7 3242 0.65 0.20 0.85 WEB FORCE WEB FORCE 2-11 -431 4- 9 -960 3-11 697 4- 8 1940 3- 9 1168 5- 8 -1407 RMB = 1.15 0 E!4. +ARc Q� N°F�c�;" 16442 STATE OFF !ND{AN pFFSS�O N AL n �arerfu LAURENS MODEL 1018 TOP CHORDS: 2x4 SP 240OF-2.OE 2x4 SPF #1/#2 (N) 1,2 BOT CHORDS: 2x4 SP #2 WEBS: 2x4 SPF STUD (N) 2x4 SPF #1/#2 (N) 2,3 2x4 SPF #3 (N) 5 MAX LIVE LOAD DEFLECTION: L/999 L=-0.22" D=-0.21" T=-0.43" MAX HORIZONTAL DEFLECTION: T= 0.13" WO: (1: Plate OFFSET from joint center. Refer to Joint Detail Report. + Denotes 90 degree plate orientation. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise TI: G TY:5 ==============Joint Locations=============== 1) 0- 0- 0 5) 28- 2- 0 9) 21- 3-12 2) 8- 2-13 6) 36- 2- 0 10) 16- 2- 0 3) 16- 1- 0 7) 36- 2- 0 11) 10-10- 4 4) 24- 0-11 8) 28- 2- 0 12) 0- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 1506 0 0 BOT PIN 36- 0- 4 1566 0 0 BOT H-ROLL 16-1-0 12-1-0 8-0-0 1 2 4 6 08 0 -8 00 4 00 [6X61 n 36-2-0 12 11 10 9 8 7 1507# 3.50" 1567# 3.50" 1-0-0 36-2-0 � 2-0-0 e I EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 scale = 0.1250 T M C YYHKIVIIVCi: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR.BRACING TRUSS MANUFACTURING COMPANY INC. WARNING: Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is apart of the building design and which must he considered by the building designer. Bracing W ESTFI ELD IND 46074 shown is for lateral support of truss members only to reduce buckling length. Provisions mast he made to anchor lateral bracing at ends and specified locations determined by the building designer. WHERE QUALITY COUNTS Additional bracing of the overall structure may be required. (See HIB-91 of TPI). For specific truss bracing requoern nls, contact building designer. (Truss Plate Instimte, TPI, is located at 183 D'Onoliio Drive, Madison, Wiscuns+- 51719). Design: Maim AmAsis JOB PATH. CrtTEE-/JJKIRI.v Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: G Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - PIt: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code De-: TPI 1-1995 TOTAL 40.0 psf V 1.01 160182-170 lire M n1 41 l CIN l GA TC FORCE AXL BND CSI 1- 2 -2135 0.21 0.75 0.96 2- 3 -1935 0.06 0.84 0.91 3- 4 -2175 0.07 0.32 0.39 4- 5 -4011 0.17 0.39 0.56 5- 6 -3495 0.19 0.47 0.66 BC FORCE AXL BND CSI 12-11 1678 0.34 0.44 0.78 11-10 1185 0.24 0.44 0.68 10- 9 1185 0.24 0.26 0.50 9- 8 2113 0.42 0.26 0.69 8- 7 3242 0.65 0.20 0.85 WEB FORCE WEB FORCE 2-11 -431 4- 9 -960 3-11 697 4- 8 1940 3- 9 1168 5- 8 -1407 RMB = 1.15 %ON\o„ E„q,Rc S'r 16442 STATE OF IND)ANA T"''S8 ON AL LAUKENN MUDEL 1018 TOP CHORDS: 2x4 SP 240OF-2.OE 2x4 SPF #1/#2 (N) 1,2 BOT CHORDS: 2x4 SP #2 WEBS: 2x4 SPF STUD (N) 2x4 SPF #1/#2 (N) 2,3 2x4 SPF #3 (N) 5 MAX LIVE LOAD DEFLECTION: L/999 L=-0.22" D=-0.21" T=-0.43" MAX HORIZONTAL DEFLECTION: T= 0.13" 11-8-6 0-4-9 [1: Plate OFFSET from joint center. Refer to Joint Detail Report. + Denotes 90 degree plate orientation. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise TI: GI TY:3 ==============Joint Locations=============== 1) 0- 0- 0 5) 28- 2- 0 9) 21- 3-12 2) 8- 2-13 6) 36- 2- 0 10) 16- 2- 0 3) 16- 1- 0 7) 36- 2- 0 11) 10-10- 4 4) 24- 0-11 8) 28- 2- 0 12) 0- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 1446 0 0 BOT PIN 36- 0- 4 1566 0 0 BOT H-ROLL 16-1-0 12-1- 8-0-0 1 2 4 6 8 00 -8 00 -4 00 [6X61 L-J - fJAV3 JAV YAO n M L' 36-2-0 �12 11 10 9 8 7 1447# 3.50" 1567# 3.50" ie 36-2-0 2-0-0 EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 •T WARNING: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR.BRACING TRUSS MANUFACTURING COMPANY INC. WARNING: Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is a part of the building design and which must he considered by the building designer. Bracing WESTFIELD IND 46074 shown is for lateral support of truss members only to reduce buckling length. Provisions must he made n) anchor lateral bracing at ends and specified locations determined by the building designer. Additional bracing of the overall structure may he required (See HIB-91 of TPQ. For specific WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located at 583 D'Onufrio Drive, Madison, Wisconsin 53719). Design: Mara Annlvsis JOB PA Tit, C1 TEE-LOXIBI:Y scale = 0.1250 Eng. Job: WO: Dwg: CENTEX Truss ID: G1 Dsgnr: JRH Chk: Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - Pit: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code Desc: TPI 1-1995 TOTAL 40.0 psf V: 1.01 16 18 -171 11C: 01.01.1, CENTEX TC FORCE AXL BND CSI BC FORCE AXL BND CSI WEB FORCE AXL BND CSI 5- 2 0 0.00 0.02 0.02 4- 3 0 0.00 0.04 0.04 WEB FORCE WEB FORCE RMB = 1.15 E. S T,&- No. F 16442 STATE OF = �Np1AN A < a" N AL `��•�`• �f�uuffu� LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x3 SPF #1/#2 (N) WEBS: 2x3 SPF #3 (N) GABLE STUD: 2x3 SPF #3 (N) All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise 0-4-9 WO: 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. Analysis based on Simplified Analog Model. MULTIPLE LOADS -- This design is the composite result of multiple loads. Wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt.-15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. TI: HGE QTY:2 ==============Joint Locations==========___== 1) 0- 0- 0 3) 4- 0- 0 5) 2- 6- 4 2) 2- 6- 4 4) 4- 0- 0 6) 0- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 0 0 0 BOT PIN 3-10- 4 0 0 0 BOT H-ROLL U 4-0-0 L �1 2 3 4 00 2X4 2X 1-8-9 3X4 2X4 2X4 4-0-0 6 5 4 0# 3.50" 0# 3.50" 2-0-0 4-0-0 -1 (R2-1-5) a EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs ® 1-4-0 o.c. scale = 0.7500 T WAKNINIU: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR.BRACING TRUSS MANUFACTURING COMPANY INC. WARNING: Bracing shnwn ton this drawing is nut erection bracing, wind bracing, pnrtal bracing or similar bracing PO BOX 418 which is a pan of the building design and which must he considered by the building designer. Bracing WESTFIELD IND 46074 shown is fur lateral support of truss members "nly too reduce buckling length. Pr"visinns must be made to anchor lateral bracing at ends and specified locations determined by the building designer. Additional bracing of the overall structure may he required. (See HIB-91 of TPI). Fur specific WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located at 583 D'Onofrio Drive, Madison, Wiuunsi� s1719). Design: M(ant Amivsis JOB PA"I C ITEE-LOKIHOME/- Eng. Job: Dwg: CENTER Dsgnr: JRH Chk: WO: Truss ID: HGE Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac -Pit: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code Deq-: TPI 1-1995 TOTAL 40.0 psf 1. 1 l 425- 35 nC� nr 01 W CENTEX TC FORCE AXL BND CSI BC FORCE AXL BND CSI WEB FORCE AXL BND CSI 9- 2 0 0.00 0.07 0.08 8- 3 0 0.00 0.20 0.20 7- 4 0 0.00 0.07 0.08 WEB FORCE WEB FORCE RMB = 1.15 ��INlllra'rfi 0 E. G S rf cF Q No. F 16442 STATE OF -�` INDIANA = o /O N Al n ���fl till 111 LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SPF #1/#2 (N) GABLE STUD: 2x3 SPF #3 (N) [1: Plate OFFSET from joint center. Refer to Joint Detail Report. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. 4-1-2 0-6-9 WO: 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. Analysis based on Simplified Analog Model. MULTIPLE LOADS -- This design is the composite result of multiple loads. Wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt-15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. TI:IGE QTV:I ==============Joint Locations=============== 1) 0- 0- 0 5) 6-11- 0 9) 2- 1- 8 2) 2- 1- 8 6) 6-11- 0 10) 0- 0- 0 3) 3- 5- 8 7) 4- 9- 8 4) 4- 9- 8 8) 3- 5- 8 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 0 0 0 BOT PIN 6- 9- 4 0 0 0 BOT H-ROLL 3-5-8 3-5-8 1 2 4 5 10 00 -10 00 5X4 :1/�1►: 0-6-9 3-5-2 11 '10 9 8 7 6' 0# 3.50" 0# 3.50" (� 1-0-0 6-11-0 j� 1-0-0 I (R1-3-10) I (RI- EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs ® 1-4-0 o.c. scale = 0.5000 T M C WAKNIN(a: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR. TRUSS MANUFACTURING BRACING WARNING: COMPANY INC. Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is a part "f the building design and which must he considered by the building designer. Bracing W ESTFI ELD IN D 46074 shown is for lateral support of truss members only to reduce buckling length. Provisions must he made to anchor lateral bracing al ends and specified locations determined by the building designer. Additional bracing of the overall structure may be required. (See HIB-91 W TPI). For spccitic WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located at 583 D'Onotriu Drive, Madison, W iscar-1719). Dais": .ifal"t JOR 111711: ("-�IICf`-!.I)ti'•Rl,V Eng. Job: Divg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: IGE Date: 10-11-00 TIC Live 20.0 psf DurFac - Lbr: 1.15 TIC Dead 10.0 psf DurFac - Plt: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code Def-: TPI 1-1995 TOTAL 40.0 psf V: 1.0', 306821- 5 1f!-s /1ul (YI CEN1'EX TC FORCE AXL BND CSI 1- 2 -2050 0.08 0.17 0.25 2- 3 -2050 0.08 0.17 0.25 BC FORCE AXL BND CSI 6- 5 1545 0.06 0.21 0.28 5- 4 1545 0.06 0.21 0.28 WEB FORCE WEB FORCE 2- 5 2335 RMB = 1.00 O S No. F 16442 STATE OFF INDIAN /O N AL ��;•�`• LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x8 SP MEL-23 WEBS: 2x4 SPF #1/#2 (N) + Denotes 90 degree plate orientation. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise MAX LIVE LOAD DEFLECTION: L/999 L=-0.02" D=-0.02" T=-0.03" MAX HORIZONTAL DEFLECTION: T= 0.02" 3-5-2 0-6-9 PA11611 Top Chord MUST be continuously laterally braced (BY OTHERS) to resist buckling PERPENDICULAR to the plane of the truss. [1: Plate OFFSET from joint center. Refer to Joint Detail Report. This 1-PLY truss designed to carry 361 21' span framed to BC one face 21 0" span split -framed to opposite face TI:IGR QTY:1 ==============Joint Locations=============== 1) 0- 0- 0 3) 6-11- 0 5) 3- 5- 8 2) 3- 5- 8 4) 6-11- 0 6) 0- 0- 0 ------------ TOTAL DESIGN LOADS ------------ Uniform PLF From PLF To TC Vert L+D -60 0- 0- 0 -60 6-11- 0 BC Vert L+D -697 0- 0- 0 -697 6-11- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 2619 0 0 BOT PIN 6- 9- 4 2619 0 0 BOT H-ROLL 3-5-8 3-5-8 1 3 10 00 [6X61 [6X6] [3X12] ■ 10 00 '6 5 2620# 3.50" 6-11-0 EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 WARNING: READ ALL NOTES ON THIS SHEET. T M C A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING TRUSS MANUFACTURING CONTRACTOR. COMPANY INC. BRACING WARNING: Bracing shown on this Drawing is not erection bracing, wind bracing, papal bracing or similar bracing PO BOX 418 which is a pan of the building design and which must be considcrcd by the building designer. Bracing WESTFIELD IND 46074 shown is for lateral support of truss members only to reduce buckling length. Provisions must he made u, anchor lateral bracing at ends and specified Imations determined by the building designer. Additional bracing of the overall structure may he required. (See H IB-91 of TPI). For .cpccific WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is fixated at 583 D'Onutrio Drive, Madison, Wiscor`- S3719). DrsignMmrir AnnNsis 108 PATH: CATF_F.-LOKUNN 0-6-9 [6X6] 41 26201/ 3.50" Eng. Job: Dwg: CENTEX Dsgnr: JRH TC Live TC Dead BC Live BC Dead TOTAL 3-5-2 Chk: 20.0 psf 10.0 psf 0.0 psf 10.0 psf 40.0 psf scale = 0.5000 Truss ID: IGR Date: 10-11-00 DurFac - I.br: 1.15 DurFac - Pit: 1.15 O.C. Spacing: 24.0" Design Criteria: TPI Code Desc: TPI 1-1995 V:01.0 306822- 6 rwmK CENTEX I LAURENS MODEL 1018 TC FORCE AXL BND CSI TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SPF #1/#2 (N) BC FORCE AXL BND CSI WEBS: 2x4 SPF STUD (N) MULTIPLE LOADS -- This design is the WEB FORCE AXL BND CSI composite result of multiple loads. 3- 2 0 0.00 0.03 0.03 WEB FORCE WEB FORCE RMB = 1.15 {{{{11111ff ff 0 E. qR•,,�� No, c� 16442 S7grE OFr 1 N DIAN A D WO: 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. Analysis based on Simplified Analog Model. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. Wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt —15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. TI: JGE QTY:I ==============Joint Locations=============== 1) 0- 0- 0 3) 4- 0- 8 2) 4- 0- 8 4) 0- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 0 -11 0 BOT PIN 3-11-12 0 0 0 BOT H-ROLL 4-0-8 L 1 4 00 2X FTI 1-8-4 3X4 2X4 0-1-8 3-11-0 4 3 0# 3.50" 0# 1.50" 1-0-0 ele 4-0-8 (" (RI-0-10) r EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs CST 1-4-0 o.c. scale = 0.7500 T M C WARNING: READ ALL NOTES ON THIS SHEET. Eng. Job: Dwg: CENTEX WO: Truss ID: JGE A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING I Dsgnr: JRH Chk: Date: 10-11-00 CONTRACTOR. TIC Live 20.0 psf DurFac - Lbr: 1.15 TRUSS MANUFACTURING COMPANY INC. BRACING WARNING: Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing TIC Dead 10.0 psf DurFae - Plt: 1.15 PO BOX 418 which is a pan ul the building design and which mast he considered by the building designer. Bracing BC Live 0.0 P sf O.C. Spacing: 24.0" WESTFIELD IND 46074 he must ne shown is for lateral support of true members only t" reduce buckling length. a building made w anchor lateral bracing at ends and specified locations determined by the building designer. BC Dead 10.0 psf Design Criteria: TPI Additional bracing of the overall structure may he required. (See HIB-91 of TPI). For specific Code D,, --: TPI 1-1995 WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located at 583 D'Onolrio Drive. Madison. Wiser-1719). TOTAL 40.0 psf V:01.0-306823- 7 l)rriwr dlnnn 1"nl�cir l0f7 P1711 r-•71! 101 If/\ It, ` ,. , ULN l EX I LAURENS MODEL 1018 TC FORCE AXL BND CSI TOP CHORDS- 2x4 SPF #1/#2 (N) 1- 2 31 0.01 0.23 0.24 BOT CHORDS: 2x4 SPF #1/#2 (N) WEBS: 2x4 SPF STUD (N) BC FORCE AXL BND CSI MAX LIVE LOAD DEFLECTION: 4- 3 0 0.00 0.08 0.08 L/999 L=-0.01" D=-0.01" T=-0.01" WEB FORCE WEB FORCE MAX HORIZONTAL DEFLECTION: 2- 3 -108 T= 0.01" RMB = 1.15 0 E ` N AR c Q� NoEFF', 16442 STATE OF ifs 1NDIAN FSSIO N Al M1 All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. TI: J QTY:I I ==============Joint Locations=============== 1) 0- 0- 0 3) 4- 0- 8 2) 4- 0- 8 4) 0- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 221 0 0 BOT PIN 3-11-12 1131 0 0 HOT H-ROLL 4-0-8 1 2 4 0000 0-1-8 3-11-0 4 3 222# 3.50" 162N 1.50" 1-0-0 4-0-8 -� (° (R1-0-10) EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 scale = 0.7500 WARNING: READ ALL NOTES ON THIS SHEET. Eng. Job: WO: T M C A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING Dwg: CENTEX Truss ID: J CONTRACTOR. Dsgnr: JRH Chk: Date: 10-11-00 TRUSS MANUFACTURING BRACING WARNING: TC Live 20.0 psf DurFac - Lbr: 1.15 COMPANY INC. Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing TC Dead 10.0 pSr DurFac - Pit: 1.15 PO BOX 418 which is a pan of the building design and which must he considered by the building designer. Bracing BC Li00 sf O.C. Spacing: 24.0" shown is for lateral support of truss member Live . only to reduce buckling length. Provisions must he p WESTFIELD IND 46074 made to anchor lateral bracing at ends and specified locations determined by the building designer. Design Criteria: TPI Additional bracing of the overall structure may he required. (See HIB-91 of TPI). For specific BC Dead 10.0 pSr WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located at Code Desc: TPI 1-1995 583 D'Onofrio Drive, Madison, Wiscon,;- 53719). TOTAL 40.0 pSf V •01.0-306825- 8 JOR PATH: C.-ITF.F-l.0KY11N I1CS nl ql CENTEX I TC FORCE AXL BND CSI 1- 2 22 0.01 0.12 0.13 BC FORCE AXL BND CSI 4- 3 0 0.00 0.04 0.04 WEB FORCE WEB FORCE 2- 3 -81 RMB = 1.15 ,��wrrrrrlrr, ST c . No, f F 16442 STATE OF INDIAN A /0 N M- �00`� jj1irru% LAURENS MODEL 1018 TOP CHORDS: 2x4 SPF #1/#2 (N) BOT CHORDS: 2x4 SPF #1/#2 (N) WEBS: 2x4 SPF STUD (N) MAX LIVE LOAD DEFLECTION: L/999 L= 0.00" D= 0.0011 T= 0.00" MAX HORIZONTAL DEFLECTION: T= 0.00" 0-4-1 All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. TI: JI QTY:3 ==============Joint Locations=============== 1) 0- 0- 0 3) 3- 0- 8 2) 3- 0- 8 4) 0- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 181 0 0 SOT PIN 2-11-12 121 0 0 BOT H-ROLL 3-0-8 �1 2 04 0 2X T1-4-4 3X4 2X4 0-1-8 2-11-0 4 3l 182# 3,50" 122# 1.50" 1-0-0 3-0-8 r (R1-0-10) EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 scale = 0.7500 T M C TRUSS MANUFACTURING WARNING: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR. Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: 1VO: Truss ID: J1 Date: 10-11-00 TC Live 20.0 psf DurFac - Lbr: 1.15 COMPANY INC. BRACING WARNING: Bracing shown on this Drawing is not erection hracing, wind bracing, portal bracing or similar bracing TC Dead 10.0 p sf DurFac - Pit: 1.15 PO BOX 418 which is a part ut the building design and which must he considered by the building designer. Bracing BC Live 0.0 Psi` P O.C. Spacing: 24.0" WESTFIELD IND 46074 shown is for lateral support of truss members only to reduce buckling length. Provisions must he made w anchor lateral bracing at ends and specified locations determined by the building designer. BC Dead 10.0 psf er Design Criteria: TPI Additional bracing(it the overall structure may he required. (See HIB-91 of TPI). For specific _ Code DP"^( TPI I-199a WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute. TPI, is located at 583 D'Onutrio Drive, Madison. Wiwi), 1719). TOTAL 40.0 psf V:01.(). 306826- 9 MR P1711 i 11! /!14 RIV fll'1 ri,...... CENTEX TC FORCE AXL BND CSI BC FORCE AXL BND CSI WEB FORCE WEB FORCE RMB = 1.15 •`Q= No. F11 16442 STATE OF =fir 1Np1ANA O FFSSIO N NL LAURENS MODEL 1018 TOP CHORDS: 2x3 SPF #1/#2 (N) BOT CHORDS: 2x3 SPF #1/#2 (N) Analysis based on Simplified Analog Model. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. MULTIPLE LOADS -- This design is the composite result of multiple loads. Wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt.=15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. TI: VA011008 QTYA ==============Joint Locations=============== 1) 0- 0- 0 3) 3- 0- 0 5) 0- 0- 0 2) 1- 6- 0 4) 3- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 0 0 0 BOT PIN 2-10- 4 0 0 0 BOT H-ROLL 1-6-0 k 1-6-0 Ilk 1 1 3 10 00 -10 00 2X5 T 1-3-6 1-3-6 0-0-6 0-0-6 2X5 2X5 3-0-0 5 4 0# 3.50" 0# 3.50" F 3-0-0 EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs ® 4-2-0 o.c. T M C WARNING: READ ALL NOTES ON THIS SHEET. Eng. Job: A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING Dwg: CENTEX CONTRACTOR. Dsgnr: JRH Chk: TRUSS MANUFACTURING BRACING WARNING: TC Live 20.0 psf COMPANY INC. Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing TC Dead 10.0 psf PO BOX 418 W ESTFI ELD IND 46074 which is a part of the building design and which must be considered by the building designer. Bracing shown is for lateral support of truss members only to reduce buckling length. Provisions must he BC Live 0.0 psf made to anchor lateral bracing at ends and specified hwations determined by the building designer. Additional bracing of the overall structure may he required. (See HIB-91 of TPH. For specific $C Dead 10.0 psf WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI. is heated at 583 D'Onofriu Drive, Madis(,n, Wisconsin 53719). TOTAL 40.0 psf Design: MMrarit Analysis JOB PATH. C, ITF_F-C.OXIBIN scale = 0.7500 WO: Truss ID: VA011008 Date: 2-10-00 DurFac - Lbr: 1.15 DurFac - Pit: 1.15 O.C. Spacing: 24.0" Design Criteria: TPI Code Desc: TPI 1-1995 IQ�'lt„It� CENTEX TC FORCE AXL BND CSI BC FORCE AXL BND CSI WEB FORCE AXL BND CSI 5- 2 0 0.00 0.37 0.37 WEB FORCE WEB FORCE RMB = 1.15 N�0 ,E �101Ar1,r'' R01 G S Tt ''� No. c� 16442 —STq E OF = IN DIA NA` �4 O �C,\ ���' FFSS/OVAL �,.• LAURENS MODEL 1018 TOP CHORDS: 2x3 SPF #1/#2 (N) BOT CHORDS: 2x3 SPF #1/#2 (N) GABLE STUD: 2x3 SPF #3 (N) MULTIPLE LOADS -- This design is the composite result of multiple loads 2-7-6 0-0-6 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. Analysis based on Simplified Analog Model. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. Wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt.=15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. Ti: VA021008 QTY:1 ==============Joint Locations=============== 1) 0- 0- 0 3) 6- 2- 6 5) 3- 1- 3 2) 3- 1- 3 4) 6- 2- 6 6) 0- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 0 0 0 BOT PIN 6- 0-10 0 0 0 BOT H-ROLL 3-1-3 k 3-1-3 L �1 f 3 10 00 -10 00 4X4 2X5 2X4 2X5 2-7-6 0-0-6 0# 3.50" 0# 3.50" 6-2-6 -� EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs @ 4-2-0 o.c. T M C WARNING: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING Eng. Job: Dwg: CENTEX I CONTRACTOR. Dsgnr: JRH Chk: TC Live 20.0 psf TRUSS MANUFACTURING BRACING WARNING: COMPANY INC. Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing TC Dead 10.0 psf PO BOX 418 which is a part or the building design and which must he considered by the building designer. Bracing Live BC Li0.0 W ESTFI ELD IN D 46074 shown is for lateral support or truss members only to reduce buckling length. Provisions must he psf P made to anchor lateral bracing at ends and specified locations determined by the building designer. Additional bracing BC Dead 10.0 sf p WHERE QUALITY COUNTS or the overall structure maybe required. (Ste HIB-91 nr TPI). For spccific truss bracing requirements, cumact building designer. (Truss Plate Institute, TPI, is located at 583 D'Onorrio Drive, Madison, Wiwon•;- M19). TOTAL 40.0 psf Desi,en: Mnrrir AnnAsis JOB PATH C ITEE-VOKIBIN scale = 0.7500 Truss ID: VA021008 Date: 2-10-00 DurFac - Lbr: 1.15 DurFac - Plt: 1.15 O.C. Spacing: 24.0" Design Criteria: TPI Code Detw: TPI 1-1995 Il(-.S 01 Ill 01 TC FORCE AXL BND CSI BC FORCE AXL BND CSI WEB FORCE AXL BND CSI 5- 2 0 0.00 0.89 0.89 WEB FORCE WEB FORCE RMB = 1.15 t; S TF No. F 16442 STATE OF= INDIANA 17; FSS10 N Al LAURENS MODEL 1018 TOP CHORDS: 2x3 SPF #1/#2 (N) BOT CHORDS: 2x3 SPF #1/#2 (N) GABLE STUD: 2x3 SPF #3 (N) MULTIPLE LOADS -- This design is the composite result of multiple loads 3-11-6 0-0-6 WO: 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. Analysis based on Simplified Analog Model. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise. wind analysis based on: ASCE-Combined, V= 75 MPH, I=0.90, Mean Hgt.=15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. TI: VA031008 QTY:1 ==============Joint Locations=============== 1) 0- 0- 0 3) 9- 4-13 5) 4- 8- 7 2) 4- 8- 7 4) 9- 4-13 6) 0- 0- 0 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 0 0 0 BOT PIN 9- 3- 1 0 0 0 BOT H-ROLL 4-8-7 4-8-7 1 3 10 00 10 00 4X4 2X5 2X4 2X5 3-11-6 0-0-6 T_ 9-4-13 6 5 0# 3.50" 0# 3.50" 9-4-13 -1 EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs ® 4-2-0 o.c. scale = 0.5000 T M C WARNING: READ ALL NOTES ON THIS SHEET. Eng. Job: Dwg: CENTEX WO: Truss ID: VA031008 A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING I Dsgnr: JRH Chk: Date: 2-10-00 CONTRACTOR. TRUSS MANUFACTURING TC Live 20.0 psf DurFac - Lbr: 1.15 COMPANY INC. BRACING WARNING: Bracing shown on this drawing is our erection bracing. wind hracing, portal bracing or similar bracing TC Dead 10.0 psf DurFac - Pit: 1.15 PO BOX 418 which is apart of the building design and which must he considered by the building designer. Bracing BC Live 0.0 psf O.C.S acing : 24.0" P g WESTFIELD IND 46074 it) is (or lateral support of truss members only , reduce buckling length. Provisions must he made to anchor lateral bracing at ends and specirted fixations determined by the building designer. BC Dead 10.0 psf Design Criteria: TPI Additional bracing of the overall structure may he required. (See HID-91 of TPI). For specific Code Desc• TPI 1-1995 WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is fixated at 583 D'Onufriu Drive, Madison. Wisconsin 53719). JOB PATHS C-ITFF-LOKMN TOTAL 40.0 psf `: 1 .1 fi0187-17S llf"ti ill !ll �.� Design: Mruri.r Annlvsis CENTEX TC FORCE AXL BND CSI BC FORCE AXL BND CSI WEB FORCE AXL BND CSI 10- 2 0 0.00 0.08 0.09 8- 3 0 0.00 0.79 0.79 7- 4 0 0.00 0.08 0.09 WEB FORCE WEB FORCE RMB = 1.15 �0E.Ac� No. F 16442 STATE OF _ =fir INDIAN _ /0 N AL ,AURENS MODEL 1018 TOP CHORDS: 2x3 SPF #1/#2 (N) BOT CHORDS: 2x3 SPF #1/#2 (N) GABLE STUD: 2x3 SPF #3 (N) [I: Plate OFFSET from joint center. Refer to Joint Detail Report. All COMPRESSION Chords are assumed to be continuously braced unless noted otherwise 5-3-6 0-0-6 WO: 2X4 TRANSVERSE BRACING nailed flat to edge of web with 12d nails at 8" o.c. TRANSVERSE BRACING to extend for center 80% of length. Analysis based on Simplified Analog Model. MULTIPLE LOADS -- This design is the composite result of multiple loads. Wind analysis based on: ASCE-Cowbined, V- 75 MPH, I=0.90, Mean Hgt.=15.0 ft, Exp. Cat. C, internal pressure coef. I, interior zone. TI: VA041008 TY:1 =------ =-- ==Joint Locations=============== 1) 0 0- 0 5) 12- 7- 3 9) 6- 0- 0 2) 2- 3-10 6) 12- 7- 3 10) 2- 3-10 3) 6- 3-10 7) 10- 3-10 11) 0- 0- 0 4) 10- 3-10 8) 6- 3-10 ----MAX. REACTIONS PER BEARING LOCATION----- X-Loc Vert Horiz Uplift Y-Loc Type 0- 1-12 0 0 0 BOT PIN 12- 5- 7 0 0 0 BOT H-ROLL 6-3-10 6-3-10 Ilk 1 2 4 5 10 00 -10 0000 [5X41 2X5 2X4 2X4 2X4 2X5 2X5 5-3-6 0-0-6 � 12-7-3 11 10 9 8 7 6 0B 3.50" ON 3.50" `e 12-7-3 EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs Q 2-0-0 o.c. scale = 0.3750 T M C TRUSS MANUFACTURING WARNING: READ ALL NOTES ON THIS SHEET- A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR. BRACING WARNING: Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: VA041008 Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 COMPANY INC. Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing TC Dead 10.0 psf DurFae - Pit: 1.15 PO BOX 418 which is a part of the building design and which must be considered by the building designer. Bracing shown is for lateral support of truss members only to reduce buckling length. Provisions must he BC Live 0.0 psf O.C. Spacing: 24.0" W ESTFI ELD IND 46074 made to anchor lateral bracing at ends and specified locations determined by the building designer. Additional bracing BC Dead 10.0 p sf Design Criteria: TPI WHERE QUALITY COUNTS of the overall structure may he required. (See H IB-9I of TPI). For specific truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located at Code Dese• TPI 1-1995 583 D'Onofrio Drive, Madison, Wiscun^- 537I9). TOTAL 40.0 psf V• 1-160188-176 Design: Matrir Anatvsis JOB PAT11: CITE£-I.O KIBIN 1lC W tN W CENTEX I LAURENS MODEL 1018 WO: TI: VA051008 TY:1 TC FORCE AXL BND CSI TOP CHORDS: 2x3 SPF #1/#2 (N) 2X4 TRANSVERSE BRACING nailed flat to edge ==============Joint Locations=============== BOT CHORDS: 2x3 SPF #1/#2 (N) of web with 12d nails at 8" o.c. TRANSVERSE 1) 0-0- 0 5) 15- 9- 8 9) 3-10-12 BC FORCE AXL BND CSI GABLE STUD: 2x3 SPF #3 (N) BRACING to extend for center 80% of length. 2) 3-10-12 6) 15- 9- 8 10) 0- 0- 0 2x3 SPF #1/#2 (N) 2 Analysis based on Simplified Analog Model. 3) 7-10-12 7) 11-10-12 WEB FORCE AXL BND CSI MULTIPLE LOADS -- This design is the [1: Plate OFFSET from joint center. Refer 4) 11-10-12 8) 7-10-12 9- 2 0 0.00 0.28 0.28 composite result of multiple loads. to Joint Detail Report. ----MAX. REACTIONS PER BEARING LOCATION----- 8-3 0 0.00 0.72 0.72 All COMPRESSION Chords are assumed to be X-Loc Vert Horiz Uplift Y-Loc Type 7- 4 0 0.00 0.28 0.28 Wind analysis based on: ASCE-Combined, V= 75 continuously braced unless noted otherwise. 0- 1-12 0 0 0 BOT PIN MPH, I-0.90, Mean Hgt.=15.0 ft, Exp. Cat. C, 15- 7-12 0 0 0 BOT H-ROLL WEB FORCE WEB FORCE internal pressure coef. I, interior zone. RMB = 1.15 `o%"\o E r„r,,. No. F 16442 STgTE OFF 1NDIANA -.''FFSS�O 6-7-5 I 0-0-6 7-10-12 k7-10-12 Ilk 1 2 4 5 10 0000 -10 00 [5X41 2X5 2X4 4X4 2X4 0-0-6 2X5 T 1 _ _ 15-9-8 I, �10 9 8 7 6 0# 3.50" 0# 3.50" -- 15-9-8 -1 EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs C 2-0-0 o.c T M C WAKNIN(a: READ ALL NOTES ON THIS SHEET. A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING CONTRACTOR.BRACING TRUSS MANUFACTURING COMPANY INC. WARNING: Bracing shown on this drawing is not erection bracing, wind bracing, portal bracing or similar bracing PO BOX 418 which is a part of the building design and which must he considered by the building designer. Bracing WESTFIELD IND 46074 shown is for lateral support (if truss members only it) reduce buckling length. Provisions must be made to anchor lateral bracing at ends and specified locations determined by the building designer. Additional bracing of the overall structure may he required. (See HIB-91 of TPI). For specific WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is located at 583 D'Onufrio Drive, Madison, Wiscu, 53719). D,ri,esMatrir Annlcrir JOB PATII: C-ITRE-f.OK'RI.V scale = 0.2500 Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: VA051008 Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - Plt: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code D---: TPI 1-1995 TOTAL 40.0 psf V: 1-160189-177 IlCc of o/ !v, CENTEX I LAURENS MODEL 1018 WO: T1: VA061008 TY:I TC FORCE AXL BND CSI TOP CHORDS: 2x3 SPF #1/#2 (N) 2X4 TRANSVERSE BRACING nailed flat to edge == --==========Joint Locations=============== BOT CHORDS: 2x3 SPF #1/#2 (N) of web with 12d nails at 8" o.c. TRANSVERSE 1) 0- 0- 0 5) 19- 0- 0 9) 5- 2-13 BC FORCE AXL BND CSI GABLE STUD: 2x3 SPF #3 (N) BRACING to extend for center 80% of length. 2) 5- 2-13 6) 19- 0- 0 10) 0- 0- 0 2x3 SPF #1/#2 (N) 2 Analysis based on Simplified Analog Model. 3) 9- 6- 0 7) 13- 9- 3 WEB FORCE AXL BND CSI MULTIPLE LOADS -- This design is the [1: Plate OFFSET from joint center. Refer 4) 13- 9- 3 8) 9- 6- 0 9- 2 0 0.00 0.35 0.35 composite result of multiple loads. to Joint Detail Report. ----MAX. REACTIONS PER BEARING LOCATION----- 8-3 0 0.00 0.69 0.69 All COMPRESSION Chords are assumed to be X-Loc Vert Horiz Uplift Y-Loc Type 7- 4 0 0.00 0.35 0.35 Wind analysis based on: ASCE-Combined, V= 75 continuously braced unless noted otherwise. 0- 1-12 0 0 0 BOT PIN MPH, I=0.90, Mean Hgt.=15.0 ft, Exp. Cat. C, 18-10- 4 0 0 0 BOT H-ROLL WEB FORCE WEB FORCE internal pressure coef. I, interior zone. RMB = 1.15 E. A � 0 E .` oN R G STf F ; No. c� 16442 STATE OF`= 1NDIAN ,off A O 11iaunut ' — 7-10-6 0-0-6 9-6-0, 9-6-0 1 2 4 5 10 00 -10 -0 2X5 2X4 4X5 2X4 0-0-6 2X5 19-0-0 L 110 9 8 7 6� 0# 3.50" Ott 3.50" �- 19-0-0 - EXCEPT AS SHOWN PLATES ARE TL20 GA TESTED PER ANSI/TPI 1-1995 Studs ® 1-4-0 o.c. scale = 0.2500 WAKNINU: READ ALL NOTES ON THIS SHEET. T M C A COPY OF THIS DRAWING TO BE GIVEN TO ERECTING TRUSS MANUFACTURING CONTRACTOR. COMPANY INC. BRACING WARNING: Bracing shown on this drawing is not erection bracing, wind hracing, portal bracing or similar bracing PO BOX 418 which is a pan of the building design and which must he considered by the building designer. Bracing WESTFIELD IND 46074 shown is for lateral support of truss members only to reduce buckling length. Provisions must he made m anchor lateral bracing at ends and specified locations determined by the building designer. Additional bracing of the overall structure may he required. (See HIB-91 of TPI). Fur specific WHERE QUALITY COUNTS truss bracing requirements, contact building designer. (Truss Plate Institute, TPI, is heated at 583 D'Onofrio Drive, Madison, Wiscr 1719). Drri,en: Mmrir An,A,is JOB PATH CITFF-1.OR'VNIN Eng. Job: Dwg: CENTEX Dsgnr: JRH Chk: WO: Truss ID: VA061008 Date: 2-10-00 TC Live 20.0 psf DurFac - Lbr: 1.15 TC Dead 10.0 psf DurFac - Pit: 1.15 BC Live 0.0 psf O.C. Spacing: 24.0" BC Dead 10.0 psf Design Criteria: TPI Code ID TPI 1-1995 TOTAL 40.0 psf V 1. . •160190-178 !l(C 1), 'I /Y