HomeMy WebLinkAbout 18030104 Energy CertificateHome Energy Rating Certificate Rati ng Date: 2018- 10-10 TitEreWSdutions
Final Report Registry ID: 517588502 p Ekotrope ID: ILXgAO72
Your Home's Estimated Energy Use:
This home meets or exceeds the
criteria of the following:
Use [MBtuj
Annual Cost
Heating
67.5
$618
2009 International Energy Conservation Code
Cooling
3.5
$1 19
Hot Water
10.1
$90
Lights/Appliances
31.1
$1,003
Service Charges
$248
Generation (e.g. Solar)
0.0
-SO
Total:
112.3
$2,079
HERSIndex
Homo Feature Summary:
Rating Completed by:
oweurrar
Home Type:
Single family detached
Energy Rater.Matthew Timmons
rso
Conditioned Floor Area:
2,748 sq. ft.
RESNET ID:593S319
Errrsnr� 14°
Number of Bedrooms:
3
Homes lw
lm
Primary Heating System:
Furnace • Natural Gas • 92.1 AFUE
Rating Company:T51 Energy Solutions
4650 Killarney Dr, Carmel IN 46082
lw
Primary Cooling System:
Ali Conditioner • Electric . 13 SEER
317-8464655
Reference
Home IN
Primary Water Heating:
Water Heater . Natural Gas • 0.96 Energy Factor
�,...�.
w
House Tightness:
1385 CFM50 (2b3 ACH50)
Rating Provider.TSI Energy Solutions
'
0Ventilation:
None
4650 Killarney Dr, Carmel IN 46082
70
w ThbNor"
Duct Leakage to Outside:
29 CFM25
317 846 4655 S
'o
Above Giade Walls:
R-15
40
so
Ceiling:
Attic, R-38
m
Window Type:
U-Value:0.3, SHGC:0.27
1O
Zero E C
Foundation Walls:
R-10
Matthew Timmons, Certified Energy Rater
Digitally signed: 10/10/18at 8.42 AM
IECC 2009 Performance Compliance
(Zi Fnergy Solutions
Property Organization
9861 WINDSONG LN TSI Energy Solutions
INDIANAPOLIS IN .46280 hlatthe,.v Timmons Inspection Status
2018-10-10
SOM72 (AS BUILT) Builder Rater ID (RTINi 5935319
SUNRISE ON THE MONON 72_109 OLD TOWN DESIGN GROU14RESNET Registered (Confirmed]
Annual Energy Cost
Design
IECC 2009
As Designed
Performance
Heating
31 255
$1.171
Cooling
5186
$151
Water Heating
5189
5189
SubTotal - Used to determine compliance
$1,630
$1,511
Lights & Appliances
S846
$8-16
Onsite generation
SO
SO
Total
$2,477
$2,357
402.5
406.3 402.4.2.1
Performance -based compliance Air Leakage Testing
Area -weighted average fenestration
passes by 7 3%
SHGC
®
402.6 403.2.2 Mandatory Checklist
Area -weighted average fenestration Duct esrr.;
IJ-Factor _
Design exceeds requirements for IECC 2009 Performance compliance by 7.3%.
As a 3rd par% extension of -he code iunsaKtan iWing -hose reporis + cenfi hat 'his erierg, :, ore compnance document has peen created in accorciance firm the reQwrements of
Chapter d of tyre adopted international =nerg% --onservation Code based on Curate Zone x, if ramp is Drolected I certrA tnat the oullding design described herein is consistent Him
the building plans specifications and other calculati0ns submitted Arth the permit application if rating is Contirmea I cerTA that the address referenced above has been
inspected tested and mat the mandator provisions of me IECC nave Deen installed to meet or exceed me intent of the IECC or xill De verified as such b, another pain
Name Nlatthe,.•, Timmons
Organization TSI Energy Solutions
Signature:
Digitally signed 10 10%18 at 8 .42 AM
Ekotrope RATER - Version 3 1 0 2023
IECC 2009 Performance compiiance results aicu!ated .,sing Ewotrooe s erwq, alcionthm Nh¢h ,s a RESNET Accredded HERS Rating Tool
9861 WINDSONG LN
INDIANAPOLIS, IN 46280
OLD TOWN DESIGN GROUP
Ceiling Attic. R-38
Above Grade Walls R-15
Foundation Walls R-10
Framed Floor NiA
Slab R-0 0 Perimeter R-0 0 Under
Infiltration 1385 CFM50 (2 63 ACH50)
Window U-Value: 0.3, SHGC 0 27
Building Features
Duct Supply R-9 0 Return R-10 0
Duct Leakage to Outside 29.0 CFM @ 25 Pa
Total Duct Leakage 345 0 CFM @ 25 Pa
Heating Furnace • Natural Gas • 92 1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Natural Gas • 0 96 Energy Factor
As a 3rd pain extension of the code jurisdiction utilizing these reports I certify that thts energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5 if rating is Projected I Certify that the building design described herein is consistent with the
building plans specifications and other calculations submitted with the permit application If rating is Confirmed I certify that the address referenced above has been InspectedAested and
that the mandator} provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as suc n by another part, -
Name Matthew Timmons Signature
Organization TSI Energy Solutions Digitally signed 10/10/18 at 8 42 AM
Ekotrope RATER -Version 3.1.0.2023
No version of this software has been re.ie Ate or approved by CC or its affiliates
The 2004 international Energy Conservation Code is a registered trademark of the international Code ;Council (ICC'l
This software is a RESNET Accredited HERS Rating Tool
r M
RESNET HOME ENERGY (ZI -orgy Soutions
RATING Standard Disclosure
For home(s) located at: 9861 WINDSONG LN,
INDIANAPOLIS, IN
Check the applicable disclosure(s) in accordance with the Instructions on the reverse of this page
1�11. The Rater or the Rater's employer is receiving a fee for providing the rating on this home
L2. In addition to the rating. the Rater of Rater's employer has also provided the following consulting services for
this home
E:A. Mechanical system design
ElB. Moisture control or indoor air quality consulting
EC. Performance testing and/or commissioning other than required for the rating itself
WID. Training for sales or construction personnel
[IE. Other(specify)
D3. The Rater of the Rater's employee is
E[A. The seller of this home or their agent
E B. The mortgagor for some portion of the financed payments on this home
L C. An employee. contractor. or consultant of the electric and/or natural gas utility serving this home
.4. The Rater or Rater's employer is a supplier or installer of products, which may include
Products
HVAC systems
Thermal insulation systems
Air sealing of envelope or duct systems
Energy efficient appliances
Construction (builder. developer. construction contractor. etc)
Other ispecify):
Installed in this home by
Rater Employer
Rater Employer
Rater EEmpioyer
Rater ElEmployer
Rater EEmployer
Rater EEmployer
OR is in the business of
Rater EEmpioyer
Rater EiEmployer
Rater Employer
Rater Employer
Rater Employer
Rater Employer
—75. This home has been verified under the provisions of Chapter 6. Section 603 "Technical Requirements for
Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy
Services Network (RESNET). Rater Certification # 5935319
Name. Matthew Timmons Signature:
Organization. TSI Energy Solutions Digitally signed 10/10/18 at 8.42 AM
I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating
Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating
Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality
control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at
http' resnet.us/standards,RESNET_Mortgage_Industry_National_HERS_Standards.pdf
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
RESNET Form 03001-2 - Amended April 24. 2007