HomeMy WebLinkAbout 18040234 Energy CertificateHome Energy Rating Certificate Rating Date: 2018-10-12 49%,�,>E,rysi^,�ut�� Final Report Registry ID: 721428268 p Ekotrope ID: AvjgRV02 Your Home's Estimated Energy Use: Use (MBtul Annual Cost Heating 85.4 $ 765 Cooling 3.9 $124 Hot Water 10.8 $347 Lights/Appliances 42.9 $1,374 Service Charges $248 Generation (e.g. Solar) 0.0 -$0 Total: 143.1 $2,858 Moot E",NY E5o Existing Homes :40 30 szo Reference Home 1QU 90 80 ra ft c.n sr, This Home 10 S' sr. Zero EnAlgy sc #0 Home fescE-,gv Home Feature Summary: Home Type: Single family detached Conditioned Floor Area: 4,652 sq. ft. Number of Bedrooms 4 Primary Heating System: Primary Cooling System: Primary Water Heating: House Tightness: Ventilation: Duct Leakage to Outside: Above Grade Walls: Ceiling: Window Type: Foundation Walls: Furnace• Natural Gas -93 AFUE Air Conditioner -Electric • 13 SEER Water Heater • Electric • 0.93 Energy Factor 2146 CFM50 (2.85 ACH50) 50.0 CFM • 100.0 Watts 73 CFM25 This home meets or exceeds the criteria of the following: 2009 International Energy Conservation Code Rating Completed by: Energy Rater.Michael Hill RESNETID:9479271 Rating Company:TSI Energy Solutions 4650 Killarney Dr, Carmel IN 46082 317-846-4655 Rating Provider:TSl Energy Solutions 4650 Killarney Dr, Carmel IN 46082 317-846-4655 R-15 Attic, -38 e:0 U-Value:0.31, SHGC:0.3 R-11 Michael Hill, Certified Energy Rater Digitally signed: 10/12/18at 3:01 PM IECC 2009 Performance Compliance Property 14207 KODIAK DR CARMEL, IN 46201 BCE064 (AS BUILT) BEAR CREEK ESTATES 64_11000E Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PULTE HOMES (QErergySdutlons Inspection Status 2018-10-12 Rater ID (RTIN): 9479271 RESNET Registered (Confirmed) Annual Energy Cost Design IECC 2009 As Designed Performance Heating $1,691 $1,153 Cooling $227 $163 Water Heating $376 $376 SubTotal - Used to determine compliance $2,294 $1,692 Lights & Appliances $1,246 $1,243 Onsite generation $0 $0 Total $3,539 $2,935 402.5 405.3 402.4.2.1 Performance -based compliance Air Leakage Testing Area -weighted average fenestration sasses by 26.2% SHGC 402.5 40322 Mandatory Checklist Area -weighted average fenestration Duct Testing U-Factor Design exceeds requirements for IECC 2009 Performance compliance by 26.2%. As a 3rd party extension of the code jurisdiction utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected; t certify that the building design described herein is consistent with the building plans: specifications; and other calcutations submitted with the permit application. If rating is Confirmed. I certify that the address referenced above has been inspectedRested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Michael Hill Signature: 40 Organization: TSI Energy Solutions Digitally signed: 10112/18 at 3:01 PM Ekotrope RATER - Version 3.1.02026 IECC 2009 Performance compliance resul6 calculated using Ekotrope's energy algorithm. which is a RESNET Accredited HERS Ratinq Tool. 14207 KODIAK DR CARMEL, IN 46201 PULTE HOMES Building Features Ceiling Attic, R-38 Duct Supply R-10.0, Return R-10.0 Above Grade Walls R-15 Foundation Walls R-11 F2-7uT1I� • • :Ill Slab R-0.0 Perimeter, R-0.0 Under Infiltration 2146 CFM50 (2.85 ACH50) Window U-Value: 0.31, SHGC: 0.3 Duct Leakage to Outside 73.0 CFM @ 25 Pa Total Duct Leakage 622.0 CFM @ 25 Pa Heating Furnace • Natural Gas • 93 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter T of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced atXNe has been inspected.lested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or A411 be verified as such by another party. Name: Michael Hill Signature: Organization: TSI Energy Solutions Digitally signed: 10/12/18 at 3:01 PM Ekotrope RATER - Version 3.1.0.2026 No version or this software has been reviewed or approved by [CC or its affiliates. The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc (ICC') This software is a RESNET Accredited HERS Rating Tool RESNET HOME ENERGY Solutions RATING Standard Disclosure i<V46(YSIEnergy Sa�uta For home(s) located at: 14207 KODIAK DR, CARMEL, IN Check the applicable disclosure(s) in accordance with the instructions on the reverse of this page. M 1. The Rater or the Rater's employer is receiving a fee for providing the rating on this home. 2. In addition to the rating, the Rater of Rater's employer has also provided the following consulting services for this home: _71A. Mechanical system design B. Moisture control or indoor air quality consulting C. Performance testing and/or commissioning other than required for the rating itself D. Training for sales or construction personnel E. Other(specify) if 3. The Rater of the Rater's employee is: :]A. The seller of this home or their agent B. The mortgagor for some portion of the financed payments on this home C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home 4. The Rater or Rater's employer is a supplier or installer of products, which may include: Products Installed in this home by OR is in the business of HVAC systems Rater Employer Rater Employer m Thermal insulation systems Rater 7 Employer Rater r7Employer Air sealing of envelope or duct systems Rater Employer Rater aEmployer Energy efficient appliances Rater E.Employer Rater Employer Construction builder, developer, construction contractor, etc Rater Employer , ... ( p ) ..E. Rater l ;Employer Other (specify): EIRater FlEmployer -Rater ? Employer 5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). Rater Certification #: 9479271 Name: Michael Hill Organization: TSI Energy Solutions Signature: 40 Digitally signed: 10/12/18 at 3:01 PM I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at http iresnet.us'standa ds RESNET.",-.Mo,tga.ae_...Industry_. National HERS Standards,pdf The Home Energy Rating Standard Disclosure for this home is available from the rating provider. RESNET Form 03001-2 - Amended April 24, 2007