Loading...
HomeMy WebLinkAbout0419.01 Building Plans1. ALL WORK SHALL BE GOVERNED BY THE LATEST ADOPTED FEDERAL, STATE AND LOCAL CODES, REGULATIONS AND STANDARDS. THEY SHALL GOVERN THE CHARACTER, QUALITY, STYLE, TYPE AND CAPACITY OF ALL INSTALLATIONS, MATERIALS AND EQUIPMENT USED. 2. ALL STATE AND LOCAL AGENCY APPROVALS AND PERMITS SHALL BE OBTAINED PRIOR TO CONSTRUCTION. 3. GENERAL CONTRACTOR IS TO VERIFY ALL EXISTING FIELD CONDITIONS, DIMENSIONS, EQUIPMENT, ITEMS PROVIDED BY THE OWNER AND LOCATION OF ALL UTILITIES TO THE SPACE PRIOR TO CONSTRUCTION. VERIFY THE SIZE AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL WORK, ELECTRICAL WORK AND EQUIPMENT WITH SUBCONTRACTORS INVOLVED. IF DISCREPANCIES EXIST, NOTIFY THE ARCHITECT. 4. GENERAL CONTRACTOR SHALL COORDINATE ALL PHASES AND TIMING OF CONSTRUCTION WITH ARCHITECT, TENANT AND BUILDING OWNER. 5. GENERAL CONTRACTOR IS TO ASSUME RESPONSIBILITY FOR THE COMPLETE FINISH AND BUILD -OUT OF THE PROJECT. ALL SURFACES AND EQUIPMENT EFFECTED BY THE NEW CONSTRUCTION OR MOVEMENT OR REMOVAL OF EXISTING OUTLETS, FIXTURES, WALLS, EQUIPMENT, ETC. SHALL BE REPAIRED TO MATCH SURROUNDING SURFACES. 6. IT IS THE INTENT OF THE DRAWINGS THAT ALL EXPOSED SURFACES SHALL RECEIVE FINISHES AS INDICATED ON THE DRAWINGS OR IN THE SPECIFICATIONS UNLESS OTHERWISE NOTED. IF A SURFACE IS NOT NOTED TO EITHER REMAIN UNFINISHED, EXISTING FINISH TO REMAIN OR TO RECEIVE A SPECIFIC FINISH, NOTIFY THE ARCHITECT. 7. ALL NEW WALL CONSTRUCTION SHALL BE 3-5/8" 26 GA. METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM BOARD APPLIED TO EACH SIDE. PARTITIONS SHALL EXTEND FLOOR TO 12" ABOVE CEILING HEIGHT EXCEPT AS NOTED. DEMISING PARTITIONS BETWEEN TENANTS SHALL EXTEND FLOOR TO STRUCTURAL OR FIRE RATED FLOOR OR ROOF MEMBRANE ABOVE WITH 5/8" TYPE 'X' GYPSUM BOARD APPLIED TO EACH SIDE, SEALED TO MEMBRANE ABOVE. ALL NEW WALL DIMENSIONS SHOWN ARE TO FACE OF STUD FRAMING UNLESS OTHERWISE NOTED. ALIGN NEW WALLS WITH EXISTING WALLS, COLUMNS OR SURFACES AS REQUIRED. IF THERE ARE QUESTIONS OF DESIGN INTENT, NOTIFY THE ARCHITECT FOR CLARIFICATION. MISCELLANEOUS ROOM EQUIPMENT TOILET ROOM #106 ** SINGLE ROLL TOILET TISSUE DISPENSER, CHROME, WALL HUNG. ** BRUSHED CHROME 'C' FOLD PAPER TOWEL DISPENSER, WALL HUNG. ** DROP IN OVAL WHITE CHINA SINK IN PLAS. LAM. TOP (INSUL. PIPES) w/ LAVATORY FAUCET & SINGLE LEVER HANDLE ** HANDICAPPED WHITE CHINA TOILET w/ POWER FLUSH ** 30" & 42" BRUSHED CHROME STAINLESS STEEL GRAB BARS TOILET ROOM #122 ** SINGLE ROLL TOILET TISSUE DISPENSER, CHROME, WALL HUNG. ** BRUSHED CHROME 'C' FOLD PAPER TOWEL DISPENSER, WALL HUNG. ** H.C. WALL HUNG WHITE CHINA SINK (INSUL. PIPES) w/ LAVATORY FAUCET & SINGLE LEVER HANDLE ** HANDICAPPED WHITE CHINA TOILET w/ POWER FLUSH ** 30" & 42" BRUSHED CHROME STAINLESS STEEL GRAB BARS LOUNGE #120 ** STAINLESS STEEL 24"x21" SINK IN PLASTIC LAMINATE COUNTERTOP w/ GOOSENECT FAUCET AND DOUBLE BLADE CHROME HANDLES ** BRUSHED CHROME 'C' FOLD PAPER TOWEL DISPENSER, WALL HUNG. DARK RM. #113 ** FIBERGLAS FREE STANDING LAUNDRY TUB SINK w/ SWIVELING GOOSENECT FAUCET AND DOUBLE BLADE CHROME HANDLES ** BRUSHED CHROME 'C' FOLD PAPER TOWEL DISPENSER, WALL HUNG. LAB #114 ** STAINLESS STEEL 24"x21" SINK IN PLASTIC LAMINATE COUNTERTOP w% GOOSENECT FAUCET AND DOUBLE BLADE CHROME HANDLES, CLAY TRAP ** BRUSHED CHROME 'C' FOLD PAPER TOWEL DISPENSER, WALL HUNG. STERILIZATION #115 ** DOUBLE STAINLESS STEEL SINK IN PLASTIC LAMINATE COUNTERTOP w/ GOOSENECT FAUCET, SINGLE LEVER CHROME HANDLE AND HOSE SPRAYER ** BRUSHED CHROME 'C' FOLD PAPER TOWEL DISPENSER, WALL HUNG. ADD ALTERNATE BID: HYGIENE ROOMS #109, 110 ** STAINLESS STEEL BAR TYPE SINK IN PLASTIC LAMINATE COUNTERTOP w/ CHROME FAUCET AND SINGLE LEVER CHROME HANDLE a ® RAME"W lel 0 C) a-1 o Q a� DOOR SIZE _ C Q ®� o z o_ ®,� Q � w �� Q_ �� w Q z �I. z Q REMARKS 1 EXIST'G 3'-0"x7'-0" ANDD. ALUM. DARK BRONZE 5/8" INSL. TEMP. ANDD. ALUM. DARK BRONZE MANFR. PUSH/PULL HARDWR., CLOSERS, THRESHOLD, DEAD BOLT W1 THUMB TURN, WEATHERSTRIP 2 3'-O"x7'-0"x1 3/4" FRENCH S.C. WD. STAIN TEMP. H.MTL. PAINT LOCKSET, CLOSER 3 3'-O"x7'-0"x1 3/4" FRENCH S.C. WD. STAIN 1/4" TEMP. H.MTL. PAINT PRIVACY LOCKSET, CLOSER 4 3' -0"x7' -0"x1 3/4" S.C. WD. STAIN H.MTL. PAINT PRIVACY LOCKSET 5 3'-0"x7'-O"x1 3/4" S.C. WD. STAIN H.MTL. PAINT LOCKSET 6 PAIR 3' -0"x7' -Q" BIFOLD S.C. WD, STAIN WOOD PAINT PULL KNOBS 7 3' -0"x7' -0"x1 3/4" S.C. WD. STAIN H.MTL. PAINT PASSAGE LATCH SET 8 3' -0"x7' -0"x1 3/4" S.C. WD. STAIN H.MTL. PAINT PROPCDQWNC KSETSWEEP DGE RIP LIGHT SEALS 9 PAIR 2' -6"x7' -0"x1 3/4" S.C. WD, STAIN H.MTL. PAINT TOP & BOTTOM BOLTS, PASSAGE LATCH SET 10 3'-0"x7'-0" POCKET S.C. WD. STAIN H.MTL. PAINT RECESSED FINGER PULLS, END PULL & LATCH 11 PAIR 2' -6"x7' -O" BIFOLD WOOD STAIN WOOD PAINT PULL KNOBS 12 3'-O"x7'-O"x1 3/4" S.C. WD, STAIN H.MTL. PAINT PASSAGE LATCH SET 13 2'-O"x7'-O"x1 3/4" S.C. WD. STAIN H.MTL. PAINT PASSAGE LATCH SET 14 3' -0"x7' -0"x1 3/4" S.C. WD. STAIN H.MTL. PAINT 45 MIN. PASSAGE LATCH SET 15 EXISTING 3'-O"x7'-0"x1 3/4" INSUL H.MTL. PAINT H.MTL. PAINT LOCKSET, DEADBOLT LOCK, CLOSER, THRESHOLD WEATHERSTRIP, STRIKE GUARDS, TAMPER PROOF HINGES ALL LOCKSETS ARE TO BE MASTERKEYED WITH AN ADDITIONAL SEPARATE KEY PROVIDED FOR EACH LOCK, ALL LOCK CYLINDERS ARE TO BE AS MANUFACTURED BY "BEST" ACCESS SYSTEMS. DOOR HARDWARE FINISH IS TO MATCH ALUMINUM STORERONTS WITH 26D FINISH ON WOOD AND HOLLOW METAL DOORS. 8 -x8 ­x4^ CLLAh 3'-6" CASED OPENING 118" ( 4'-8" 1 1� i Tro�rn nl ncc DI nnv n®I'nunlc ELEVATIo� A ELEVATION B ELEVATIO M 0 w 7 m a z 00 L _ I 00 N M co en 34'-6 9/16" I 3 5/8" 3 5/8" 3 5/8" 3 5/8" 11'-1 1/2" 4'-1" 3'-11" 8'-8 9/16" 5'-6"r777777777777774 7 1,17177=1 1 ' 7 J I x KTAKS TANK ROOM ENCL. (� I 121 IS TO BE ONE HOUR U RATED CONSTRUCTION 0 5/8" TYPE 'X' G.B. _ TREATMENT #2 00® EACH SIDE OF WALL M w/ 2 LAYERS ON STAFF 119 CEILING (A-) LOUNGETOILET t2Q � t22 0 REF. BY TENANT W/D B EQUIPMENT TENANT 115 000 11'-i 3/16" M 1 7'-4" TREATMENT #1 I0 STERILIZATION 3 5/8" t t LAB 11 1 t4 11 00 STORAGEM N ° a _ O oc I o ,w) I X D K RM. FILE RM, M X - RAY t t3 104 HYGIENE 2 „2 t t0 `4 a HALL 5,_8" 5'-19/16" ru- O 1t1 7-4" r 4'-6„ ADMINISTRATION Fl 031I M «> GLASS I I 1'-0 3/4" BLOCK //I) ( 5'-2 1/2" 3' 0' HYGIENE # 1 tog o CHECK OUTOI , I to, x Lr, 150' TORAGE tai � `'1° � �- ® � � o ~' 6h 2'-3 5/8 3'-4" BLOCK 6 GLASS CHECK IN UD if GLASS BLOCK OFFICE � H.C. 1a7 TOILET I VESTIBULE `00, WAITING Lr) tQi r- GLASS 102, BLOCK / 11'-1 1/2" 11 5'-6" SCALE: 1/4" = 1'-0" I 00 00 N 00 M IN' KEY PLAN 0 c Io W 0 Sal tV Q' w N O LLj QLL c�% ti Opo cc o r-, :.oto M F- '4,­ -. � . � -. 61 to x NN w M C6 M T T VC� � '�j h P• 0(D MT co Ate m _ o jE m a Z C -O cn C w C-7 tl � C Io W 0 Sal tV Q' w N O LLj QLL c�% ti Opo cc o r-, :.oto M F- '4,­ -. � . � -. 61 to x NN w M C6 M T T VC� � '�j h P• 0(D MT co Ate m _ o jE m a ROOM FINISH SCHEDULE uW4830 W3624 W4830 B48 SB36 DB4-18 B30 TERIL17ATION -. 0 MELAMINE SHELF @ D R11 A @ 36" A.F.; 66" A.F. STORAGE11 7 o (4) 18" WIDE MELAMINE '�4 LAB SHELVES ON H.D. STANDARDS SECURE OPEN & BRACKETS ADMINISTRATION D K RM. X—RAY DB4-15 SB30 618 113 J 112 Q ii V � Z TRANSACTION B33 OPEN O M 30" WIDE PLASTIC LAM. WORK 4 TOP @ 427A. F.— co �- TOP @ 30 A.F. o N G PENCIL .. F— W N Z DRAWER H CK �� -� PENCIL T OUT ,% DRAWER 105 n n >Q. C N N com Iwo r' o `m FLOORCOVERING WALLCOVERING PAINT -LAMINATES MISCELLANEOUS TREATMENT #2 119 PROVIDE BLOCKING IN u WALL @ 84" A.F. FOR THRU WALL XRAY FUTURE VIDEO MONITORS EQUIPMENT; VERIFY TYPICAL OF 4 LOCATIONS OPENING w/ DENTAL EQUIPMENT SUPPLIER TREATMENT #1 01181 1'-4'1 5-8" ADD ALTERNATE BID: PROVIDE THE ADDITIONAL M o COST IF PROVIDING ALL OF HYGIENE #2 THE CABINETRY, PLAS. LAM. 11 > 3 COUNTERTOPS AND SINKS 2'-4" IN HYGIENE ROOMS ILI #109, 110" VBS36 OPEN B LOW Q o i THRU WALL XRAY EQUIPMENT; VERIFY VBS36 OPEN BELOW OPENING w/ DENTAL t'-4 5'-8" EQUIPMENT SUPPLIER 0 HYGIENE 1 4 3 1 21" DP. WORK TOP VB36 V836 VB24 @ 33" A.F. W3630 W3630 W3030 TS ORAGE108 JR11 & SHELF (4) 12 WIDE MELAMINE SHELVES ON H.D. STANDARDS & BRACKETS LOUNGE 128 S830 D84-12 624 W3624 MOS30 W3012 W3030 STAFF TOILET 122 E UIPMENT 115 o uW4830 W3624 W4830 B48 SB36 DB4-18 B30 TERIL17ATION -. 0 MELAMINE SHELF @ D R11 A @ 36" A.F.; 66" A.F. STORAGE11 7 o (4) 18" WIDE MELAMINE '�4 LAB SHELVES ON H.D. STANDARDS SECURE OPEN & BRACKETS ADMINISTRATION D K RM. X—RAY DB4-15 SB30 618 113 J 112 Q ii V � Z TRANSACTION B33 OPEN W3030 STAFF TOILET 122 E UIPMENT 115 o FLIP UP WORK TOP, / \ (1) FIXED 12" WIDE 111 - 0 MELAMINE SHELF @ D w/ WORK TOP @ 36" A.F.; 66" A.F. J W o ON WALL TO LAB i SECURE OPEN TOP ADMINISTRATION � O CL DB4-15 SB30 618 o J FILE RM, l!.�J HALL FLIP UP WORK TOP, / \ (1) FIXED 12" WIDE 111 HINGED AT WALL, FLUSH MELAMINE SHELF @ D w/ WORK TOP @ 36" A.F.; 66" A.F. O M PROVIDE LATCH ON WALL TO o p i SECURE OPEN TOP ADMINISTRATION � O CL 1 o � o 15" WIDE P.L.6"R Q ii V � Z TRANSACTION 1 O M 30" WIDE PLASTIC LAM. WORK 4 TOP @ 427A. F.— co �- TOP @ 30 A.F. o N G PENCIL .. F— W N Z DRAWER H CK �� -� PENCIL T OUT ,% DRAWER 105 n n OFFICE H.C. 7 TOILET olm 0 PL=== -Ll Nzz:�7 :Z� 12" WIDE P.L. TRANSACTION TOP @ 42"A.F. CHECK IN 30"Wx24"D PLAS. LAM LAV. TOP @ 33" A.F. WAITING 182 VESTIB LE 101 24"W. PLAS. LAMINATE WORK TOP @ 30" A.F. (2) 12" WIDE MELAMINE SHELVES ON HEAVY DUTY ADJUSTABLE BRACKETS & WALL STANDARDS 6" DROP IN COUNTERTOP 'PROVIDE CLOSURE PROVIDE BLOCKING ABOVE SINK FOR PLASTER BIN; VERIFY w/ D.E.S. (4) 18" WIDE MELAMINE SHELVES ON H.D. STANDARDS & BRACKETS 24" WIDE PLASTIC LAM. WORK TOP @ 30" A.F. 2" GROMMET HOLES IN COUNTERTOPS (TYP. OF 5) SEE WALL DIMENSIONS ON SHEET A-1 CABINETRY "'a' FIN PLAN Ilham D r: PLAN sm C 0 o p c c E N w rL- 6 E dsd Z Q D z W O M V o p i V 0 Z Q v °s W � O CL Baa o � o Q ii V � Z o o C� J O M 4 U co N G .. F— W N Z X01111i1UJ1,,00 ,% 3cn i ti tea. (Irk \ K 110- flt. >Q. C N N com r' o `m FIXTURE SCHEDULE 2' X 4' (4) LAMP FLUORESCENT RECESSED TROUFFER, 120V METALUX OR EQUAL W/ ACRYLIC PRISMATIC LENSE "P" INDICATES 1 /2"x 1 /2" PARAWEDGE CHROME LENSE 0 RECESSED 75W INCANDESCENT "CAN" LIGHT HALO OR EQUAL ® EXHAUST FAN, NUTONE OR EQUAL. {� EXIT LIGHT WITH BATTERY E DIRECTIONAL EMERGENCY EXIT LIGHT WITH BATTERY 15A, SINGLE POLE SWITCH �3 15A, 3 -WAY SWITCH tR SLIDE CONTROL RHEOSTAT SWITCH, SIZED FOR LOAD 2' X 4' (4) LAMP FLUORESCENT SURFACE MTD. TROUFFER, 120V METALUX OR EQUAL. 2' X 4' (4) LAMP OR 2' X 2' FLUORESCENT RECESSED TROUFFER, 120V METALUX OR EQUAL. HALF OF LAMPS ALWAYS ILLUMINATED (NIGHT LIGHT) PROGRESS #P3520-30 WHITE UTILITY LIGHT OR EQUAL WALL MOUNTED 75W INCANDESCENT DECORATIVE SCONCE FIXTURE (SEE INTERIOR DETAILS FOR TYPE) LAY -IN RECESSED AIR DIFFUSERS AND RETURN AIR GRILLES SEE H.V.A.C. PLAN O CEILING SPEAKER LOCATION; PROVIDED AND INSTALLED BY S TENANT'S CONTRACTOR APPROX. LOCATION FOR ATTIC MASTER CONTROL SWITCH FOR EQUIP. SUPPLIER MAE9lL4KMjM9j1j 11 1 m PLAN eutow a ms c c � � L o w c E Cyd (A VL Sg.=- E o s� 8 a`Naa S Q z Q 0 z w o :2 o p V 9) V 0 z Q ch V) w r)ollo LAJ ro 9 C:) CL o o < z o o p oRanw Q V 000 C'4 o " f'— V N ' Z p W W H N c � soy .000 . .............. �pp •C Jc- ' ( N N to co � rr Z 01 01 f: f: CDLco co m o.: IE A -3 HVAC GENERAL NOTES 1. WORK SHALL BE DONE IN STRICT ACCORDANCE WITH ALL LOCAL, COUNTY AND STATE CODES AND ALL APPLICABLE LAWS, RULES AND REGULATIONS COVERING THE INSTALLATION OF HEATING, VENTILATING AND AIR-CONDITIONING SYSTEMS. 2. THE MECHNICAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES AND INSPECTION FEES AS REQUIRED FOR THE INSTALLATION OF THE HVAC SYSTEMS. 3. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ORDERING EQUIPMENT WITH THE PROPER VOLTAGES TO MATCH EXISTING ELECTRICAL SERVICE AVAILABLE. 4. AIR HANDLING UNITS SHALL BE HUNG IN THE ATTIC. CONTRACTOR SHALL PROVIDE ALL ANGLES, RODS AND BEAMS TO SUSPEND UNITS FROM THE STRUCTURAL MEMBERS. PROVIDE AND SUPPORT SERVICE PLATFORM ON SIDE OF A.H. UNITS. PROVIDE VIBRATION ISOLATORS FOR A.H. UNITS. 5. INSULATE ALL GALVANIZED DUCTWORK WITH 1" INTERNAL LINER. 6. DUCTWORK RUNNING THROUGH ATTIC SHALL BE DOUBLE INSULATED. 7. SQUARE CEILING DIFFUSERS SHALL BE 24" X 24" PANEL TYPE, ROUND NECK AND BAKED ENAMEL FINISH. DIFFUSERS SHALL FIT 2' X 4' LAY -IN CEILING, COLOR TO MATCH CEILING SYSTEM. 8. RETURN AIR GRILLES SHALL BE EGG -CRATE 1/2" X 1/2" X 1/2' LOUVER TYPE. GRILLES SHALL LAY -IN 24" X 48" "T" BAR TYPE CEILING GRID, UNLESS OTHERWISE NOTED. 9. FURNISH ALL DIFFUSERS WITH OPPOSED BLADE VOLUME DAMPERS OPPERABLE FROM THE FACE OF DIFFUSER. 10. IN "SUPPLY" SHEET METAL DUCTWORK, PROVIDE TURNING VANES IN ALL SQUARE ELBOWS AND EXTRACTORS IN ALL BRANCH TAKE -OFFS. 11. FLUE INSTALLATION SHALL COMPLY WITH N.F.P.A. #9B AS WELL AS STATE AND LOCAL CODES. 12. PROVIDE VOLUME DAMPER AT EACH BRANCH DUCT. 13. CONNECT DIFFUSER TO SHEET METAL DUCT WITH ROUND FLEXIBLE DUCT. FLEXIBLE DUCT IS 5'-0" MAXIMUM LENGTH. NOTE: THIS PLAN IS A SCHEMATIC LAYOUT OF A SUGGESTED SYSTEM FOR THIS TENANT SPACE. IT IS THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO PROVIDE A FINAL DESIGN OF ALL UNITS, DUCT SIZES AND DUCT LAYOUTS WITH WARRANTEES AS REQUIRED BY THE BUILDING OWNER. 4" THRU WALL VGKIT YPICAL ADJUSTABLE /GLUME DAMPER YPICAL CEILING SUPPLY IR CEILING DIFFUSER YPICAL RETURN AIR GRILLE V SUSPENDED CEILING TO JR PLENUM ABOVE CEILING JSULATED FLEX DUCT ONNECTOR THRU DRYWALL ECK ISULATED METAL DUCT I ATTIC n93V93l%93(C93 F)UN OULOW 0 KE1 IN, Y PLAN Z5 �5'78O y .L cOO vQ'� �. p d O y N C 45 dC.0 E z �J z w o ckf Aft o p (9 o U z no w ccll o w C) (09o C) � o Q o � J p w M J� Q U 00 cl*4 o v z o Ln CL o sgg 008 MW` NN C Ut ctf M M titi 0 CO M CO Ad O. — `: d3 M-1 PLUMBING GENERAL NOTES: 1 . WORK SHALL BE DONE IN STRICT ACCORDANCE WITH ALL LOCAL, COUNTY AND STATE CODES AND ALL APPLICABLE LAWS, RULES AND REGULATIONS COVERING THE INSTALLATION OF PLUMBING SYSTEMS. 2. ALL HOT AND COLD WATER PIPING SHALL BE TYPE "L" HARD COPPER WITH COPPER OR WROUGHT BRASS FITTINGS. 3. ALL WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC. 4. REFRIGERATE PIPING SHALL BE TYPE T' HARD COPPER WITH SILVER SOLDERED JOINTS. 5. THE PLUMBING CONTRACTOR SHALL VERIFY WITH THE LOCAL GAS COMPANY THE LOCATION OF GAS SERVICE AND SHALL PROVIDE A COMPLETE NEW GAS SERVICE TO EACH OFFICE SUITE. 6. ALL GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE. 7. ALL SANITARY DRAIN LINES SHALL SLOPE A MINIMUMOF 1/8" PER FOOT INSIDE BUILDING. 8. INSTALL PDI RATED SHOCK ABSORBERS IN COLD WATER SYSTEM WHERE REQUIRED. ALL WATER SUPPLY PIPING TO FIXTURES SHALL BE VALVED TO ISOLATE FIXTURES FROM REMAINDER OF SYSTEM. 9. PIPE INSULATION SHALL BE 1/2" THICK FOAMED ELASTOMERIC OR 1„ THICK FIBERGLAS WITH VAPOR BARRIER. ALL INSULATION AND JACKETS SHALL NOT EXCEED A FLAME SPREAD OF 25 OR SMOKE DEVELOPED OF 150. INSULATION WILL BE REQUIRED AROUND ALL PVC PIPING IN RETURN AIR PLENUMS AS REQUIRED BY CODES. -I §LjWM:%jNjG PLAN BUILDING STE LINE KEVAQ �l X91 NT �i em c Cc C O i N 0 .O p p O 0 E� O .00 V N C 'D d N ` C Q Z Q LJ z J W m o�nno VU Q 0 o V na o U z a w � o L_Lj CIL C) c1:1-0 Caa o � o � Z f� ® p J o w Q U 00 o 0 C> g Q:� � V N Z p LAJ O W t!') C o LLLL 000.�. ✓ �: 0 '_u oc _ O F� ep woe 1111 �; C_ � � tA~ ��► t15 .CC ' N N T T Ga w T a m cGG' d. o : . . s ELECTRICAL SCHEDULE_ It 220V OUTLET, VERIFY SPECIAL PLUG CONFIGURATION ELECTRICAL 'HARDWIRE' JUNCTION BOX; VERIFY SPECIFIC EQUIPMENT REQUIREMENTS © BOX LOCATION FOR TENANT'S COMMUNICATIONS AND/OR COMPUTER NETWORK INSTALLATION a TELEPHONE BOX AND RISER, SIMPLEX b wm TELEPHONE BOX AND RISER, WALL MOUNT, SIMPLEX ® ELECTRICAL PANEL BOARD, LPA ELECTRICAL NOTES 1. CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO INITIATING WORK. 2. CONTRACTOR TO COORDINATE WORK WITH ALL OTHER TRADES. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL STATE AND LOCAL BUILDING CODES AND PER 1990 NEC. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECTS AS REQUIRED BY ALL NATIONAL AND LOCAL CODES. 5. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL SERVICE WITH LOCAL POWER COMPANY. 6. ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK IN STRICT COMPLIANCE WITH NATIONAL ELECTRICAL CODES AND LOCAL CODES. 7. ELECTRICAL CONTRACTOR SHALL NOT PROVIDE OR USE ROMAX WIRE UNLESS APPROVED BY ARCHITECT AND BUILDING OWNER. 8. ELECTRICAL CONTRACTOR SHALL NOT EXCEED EIGHT (8) DUPLEX OUTLET PER CIRCUIT. 9. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL ELECTRICAL AND TELEPHONE OUTLETS ® 15" A.F.F. TO CENTER LINE, UNLESS SPECIFED OTHERWISE ON DRAWING. ELEC IN Tf R00N OUTL REAL EQUII VERY EQUII 911NE4COTRICAL PLAN IN eNDW D KEY PLAN Boa c p y �c� o�S oyi�o E CO O p� N j N O CONVENIENCE OUTLET 20 AMP, 3 WIRE, 120 V DUPLEX RECEPTACLE NEMA 5-15R 0 =@GFl CONVENIENCE OUTLET 20 AMP, 3 WIRE, 120 V DUPLEX RECEPTACLE NEMA 5-15R na 0 WITH GROUND FAULT PROTECTION o =@ CONVENIENCE OUTLET 20 AMP, 3 WIRE, 120 V DUPLEX RECEPTACLE NEMA 5-15R Z a DEDICATED CIRCUIT LJ— 0 CONVENIENCE OUTLET 20 AMP, 3 WIRE, 120 V GFS FOURPLEX RECEPTACLE NEMA 5-15R V WITH GROUND FAULT PROTECTION CONVENIENCE OUTLET 20 AMP, 3 WIRE, 120 V o FOURPLEX RECEPTACLE NEMA 5-15R It 220V OUTLET, VERIFY SPECIAL PLUG CONFIGURATION ELECTRICAL 'HARDWIRE' JUNCTION BOX; VERIFY SPECIFIC EQUIPMENT REQUIREMENTS © BOX LOCATION FOR TENANT'S COMMUNICATIONS AND/OR COMPUTER NETWORK INSTALLATION a TELEPHONE BOX AND RISER, SIMPLEX b wm TELEPHONE BOX AND RISER, WALL MOUNT, SIMPLEX ® ELECTRICAL PANEL BOARD, LPA ELECTRICAL NOTES 1. CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO INITIATING WORK. 2. CONTRACTOR TO COORDINATE WORK WITH ALL OTHER TRADES. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL STATE AND LOCAL BUILDING CODES AND PER 1990 NEC. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECTS AS REQUIRED BY ALL NATIONAL AND LOCAL CODES. 5. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL SERVICE WITH LOCAL POWER COMPANY. 6. ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK IN STRICT COMPLIANCE WITH NATIONAL ELECTRICAL CODES AND LOCAL CODES. 7. ELECTRICAL CONTRACTOR SHALL NOT PROVIDE OR USE ROMAX WIRE UNLESS APPROVED BY ARCHITECT AND BUILDING OWNER. 8. ELECTRICAL CONTRACTOR SHALL NOT EXCEED EIGHT (8) DUPLEX OUTLET PER CIRCUIT. 9. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL ELECTRICAL AND TELEPHONE OUTLETS ® 15" A.F.F. TO CENTER LINE, UNLESS SPECIFED OTHERWISE ON DRAWING. ELEC IN Tf R00N OUTL REAL EQUII VERY EQUII 911NE4COTRICAL PLAN IN eNDW D KEY PLAN Boa c p y �c� o�S oyi�o E CO O p� N j N O H Vj 6j Ets d E 0- L' u g.�'$-� i N O .` w p H O z Q 0 z W o V D na 0 V z no Cn cm W o LAJ a � o < Z a LJ— 0 o p J o W rz Q V 00 Re— cv o W N � � W f- a o � ;P 0 Wy =cc 21 ►- c; w _ I � a . ,C w, M M Z Q, N m co 19 m co c� O`.; ...., .. [E�11