Loading...
HomeMy WebLinkAboutFooting inspection 10-10 (column footings repour)FOOTING INSPECTION Type of Footings: Column Pads Location of Footings: B-2,B-4 The above referenced footing excavations were inspected at design elevation. A visual classification of the soil, housel penetrometer and hand penetrometer tests were performed on the materials in the base of the footings. Our test results indicate soil strengths at or above 2000 psf to a depth of eighteen (18) inches below design elevation. Type of Footings: Column Pad Location of Footings: B-6 The above referenced footing excavations were inspected at design elevation. A visual classification of the soil, housel penetrometer and hand penetrometer tests were performed on the materials in the base of the footings. The test results indicate the presence of unsuitable/unstable materials. Therefore, the following modifications were made. Modifications Unstable soils were removed to a depth of 18" below design bottom of footing elevation where suitable soils were then encountered. The excavation was then re-inspected and approved for design bearing capacity of 2000 psf to a depth of eighteen (18) inches below the base of the undercut. Concrete was used to re-establish design bottom of footing elevation. Sr. Engineering Technician: Jake Williams Tested For: Mr. Alex Jakacki White Oak Construction 10967 East Crawfordsville Road Indianapolis, IN 46234 Project: Meijer Outlot C - Restaurant & Retail Shell, PO#438.1 1424 West Carmel Drive Carmel, IN A&W Project TD18202 Inspection Date: Wednesday, October 10, 2018 Report No: TD18202-FTG-A page 1 of 1W&A Alt & Witzig Engineering, Inc. 4105 West 99th Street · Carmel, IN 46032 (317) 875-7040 · FAX (317) 876-3705 SUBSURFACE INVESTIGATION AND FOUNDATION ENGINEERING CONSTRUCTION MATERIALS TESTING AND INSPECTION ENVIRONMENTAL SERVICES