HomeMy WebLinkAbout09 72 00 Wall CoveringsTHE KENT 09 72 00 - THE KENT Issue Date 05.09.18 WALL COVERINGS THE KENT SECTION 09 72 00 - WALL COVERINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Vinyl wall covering. 1.3 PRE-INSTALLATION MEETINGS A. Pre-installation Conference: Conduct conference at Project site. 1.4 ACTION SUBMITTALS A. Product Data: For each type of product. 1. Include data on physical characteristics, durability, fade resistance, and fire-test-response characteristics. B. Shop Drawings: Show location and extent of each wall-covering type. Indicate pattern placement, seams and termination points. C. Samples: For each type of wall covering and for each color, pattern, texture, and finish specified, full width by 36-inch- long in size. 1. Wall-Covering Sample: From same production run to be used for the Work, with specified treatments applied. Show complete pattern repeat. Mark top and face of fabric. D. Samples for Initial Selection: For each type of wall covering. E. Samples for Verification: For each type of wall covering and for each color, pattern, texture, and finish specified, full width by 36-inch- long in size. 1. Wall-Covering Sample: From same production run to be used for the Work, with specified treatments applied. Show complete pattern repeat. Mark top and face of fabric. 2. Wood-Veneer Wall-Covering Sample: From same flitch to be used for the Work, with specified finish applied. 1.5 INFORMATIONAL SUBMITTALS A. Qualification Data: For testing agency. B. Product Test Reports: For each wall covering, for tests performed by a qualified testing agency. THE KENT 09 72 00 - THE KENT Issue Date 05.09.18 WALL COVERINGS THE KENT 1.6 CLOSEOUT SUBMITTALS A. Maintenance Data: For wall coverings to include in maintenance manuals. 1.7 MAINTENANCE MATERIAL SUBMITTALS A. Furnish extra materials, from the same product run, that match products installed and that are packaged with protective covering for storage and identified with labels describing contents. 1. Wall-Covering Materials: For each type, color, texture, and finish, full width by length to equal to 5 percent of amount installed. 1.8 QUALITY ASSURANCE A. Mockups: Build mockups, if requested in writing by Architect, to verify selections made under Sample submittals and to demonstrate aesthetic effects and to set quality standards for installation, if requested in writing by Architect. 1. Build mockups for each type of wall covering on each substrate required. Comply with requirements in ASTM F 1141 for appearance shading characteristics. 2. Approval of mockups does not constitute approval of deviations from the Contract Documents contained in mockups unless Architect specifically approves such deviations in writing. 3. Subject to compliance with requirements, approved mockups may become part of the completed Work if undisturbed at time of Substantial Completion. B. Manufacturer Qualifications: A qualified manufacturer that is certified for chain of custody by an FSC-accredited certification body. 1.9 FIELD CONDITIONS A. Environmental Limitations: Do not deliver or install wall coverings until spaces are enclosed and weathertight, wet work in spaces is complete and dry, work above ceilings is complete, and temporary HVAC system is operating and maintaining ambient temperature and humidity conditions at levels intended for occupants after Project completion during the remainder of the construction period. B. Lighting: Do not install wall covering until lighting that matches conditions intended for occupants after Project completion is provided on the surfaces to receive wall covering. C. Ventilation: Provide continuous ventilation during installation and for not less than the time recommended by wall-covering manufacturer for full drying or curing. PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. Wall materials shall comply with the requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." THE KENT 09 72 00 - THE KENT Issue Date 05.09.18 WALL COVERINGS THE KENT B. Fire-Test-Response Characteristics: As determined by testing identical wall coverings applied with identical adhesives to substrates according to test method indicated below by a qualified testing agency. Identify products with appropriate markings of applicable testing agency. 1. Surface-Burning Characteristics: Comply with ASTM E 84; testing by a qualified testing agency. Identify products with appropriate markings of applicable testing agency. a. Flame-Spread Index: 25 or less. b. Smoke-Developed Index: 70 or less. 2. Fire-Growth Contribution: No flashover and heat and smoke release according to NFPA 286. 2.2 VINYL WALL COVERING W3 A. Refer to Finish Legend on Drawings. B. Description: Provide products in rolls from same production run and complying with the following: 1. FS CCC-W-408D and CFFA-W-101-D for Type II, Medium-Duty products. 2. ASTM F 793 for wall coverings. a. Category: II, Decorative with Medium Serviceability. C. Total Weight: 20 oz., excluding coatings. D. Width: 54 inches. E. Backing: Nonwoven fabric. F. Repeat: Straight, non-reversible match. G. Colors, Textures, and Patterns: Refer to Finish Legend on Drawings. 2.3 VINYL WALL COVERING W4 A. Refer to Finish Legend on Drawings. B. Description: Provide products in rolls from same production run and complying with the following: 1. FS CCC-W-408D and CFFA-W-101-D for Type II, Medium-Duty products. 2. ASTM F 793 for wall coverings. a. Category: II, Decorative with Medium Serviceability. C. Total Weight: 20.3 oz., excluding coatings. D. Width: 54 inches. E. Backing: Nonwoven fabric. F. Repeat: Straight, non-reversible match. G. Colors, Textures, and Patterns: Refer to Finish Legend on Drawings. THE KENT 09 72 00 - THE KENT Issue Date 05.09.18 WALL COVERINGS THE KENT 2.4 ACCESSORIES A. Adhesive: Mildew-resistant, non-staining, strippable adhesive, for use with specific wall covering and substrate application indicated and as recommended in writing by wall-covering manufacturer. 1. Adhesives shall have a VOC content of 50 g/L or less. 2. Adhesive shall comply with the testing and product requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." B. Primer/Sealer: Mildew resistant, complying with requirements in Section 09 91 00 "Painting" and recommended in writing by primer/sealer and wall-covering manufacturers for intended substrate. C. Metal Primer: Interior ferrous metal primer complying with Section 09 91 00 "Painting" and recommended in writing by primer and wall-covering manufacturers for intended substrate. D. Wall Liner: Nonwoven, synthetic underlayment and adhesive as recommended in writing by wall-covering manufacturer. 1. Adhesives shall have a VOC content of 50 g/L or less. 2. Adhesive shall comply with the testing and product requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." E. Seam Tape: As recommended in writing by wall-covering manufacturer. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates and conditions, with Installer present, for compliance with requirements for levelness, wall plumbness, maximum moisture content, and other conditions affecting performance of the Work. B. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Comply with manufacturer's written instructions for surface preparation. B. Clean substrates of substances that could impair bond of wall covering, including dirt, oil, grease, mold, mildew, and incompatible primers. C. Prepare substrates to achieve a smooth, dry, clean, structurally sound surface free of flaking, unsound coatings, cracks, and defects. 1. Moisture Content: Maximum of 5 percent on new plaster, concrete, and concrete masonry units when tested with an electronic moisture meter. 2. Plaster: Allow new plaster to cure. Neutralize areas of high alkalinity. Prime with primer recommended in writing by primer/sealer manufacturer and wall-covering manufacturer. THE KENT 09 72 00 - THE KENT Issue Date 05.09.18 WALL COVERINGS THE KENT 3. Metals: If not factory primed, clean and apply primer recommended in writing by primer/sealer manufacturer and wall-covering manufacturer. 4. Gypsum Board: Prime with primer as recommended in writing by primer/sealer manufacturer and wall-covering manufacturer. 5. Painted Surfaces: Treat areas susceptible to pigment bleeding. D. Check painted surfaces for pigment bleeding. Sand gloss, semi-gloss, and eggshell finish with fine sandpaper. E. Remove hardware and hardware accessories, electrical plates and covers, light fixture trims, and similar items. F. Acclimatize wall-covering materials by removing them from packaging in the installation areas not less than 24 hours before installation. 3.3 WALL LINER INSTALLATION A. Install wall liner, without gaps or overlaps. Form smooth wrinkle-free surface for finished installation. Do not begin wall-covering installation until wall liner has dried. 3.4 WALL-COVERING INSTALLATION A. Comply with wall-covering manufacturers' written installation instructions applicable to products and applications indicated. B. Cut wall-covering strips in roll number sequence. Change the roll numbers at partition breaks and corners. C. Install strips in same order as cut from roll. 1. For solid-color, even-texture, or random-match wall coverings, reverse every other strip. D. Install wall covering without lifted or curling edges and without visible shrinkage. E. Match pattern 72 inches above the finish floor. F. Install seams vertical and plumb at least 6 inches from outside corners and 6 inches from inside corners unless a change of pattern or color exists at corner. Horizontal seams are not permitted. G. Trim edges and seams for color uniformity, pattern match, and tight closure. Butt seams without overlaps or gaps between strips. H. Fully bond wall covering to substrate. Remove air bubbles, wrinkles, blisters, and other defects. 3.5 CLEANING A. Remove excess adhesive at seams, perimeter edges, and adjacent surfaces. B. Use cleaning methods recommended in writing by wall-covering manufacturer. C. Replace strips that cannot be cleaned. THE KENT 09 72 00 - THE KENT Issue Date 05.09.18 WALL COVERINGS THE KENT D. Reinstall hardware and hardware accessories, electrical plates and covers, light fixture trims, and similar items. END OF SECTION 09 72 00