1 DEMOLITION PLAN
AI J5CALE:1/4'=1'-0'
GENERAL DEMOLITION NOTES:
A ALL DEMOLITION ITEMS SHALL BE CONSIDERED PROPERTY OF THE OWNER UNTIL SUCH A TIME
VERIFICATION HAS BEEN MADE AS TO THOSE ITEMS NOT TO BE RETAINED BY THE OWNER PRIOR TO
REMOVAL FROM THE SITE. ALL ITEMS NOT TO BE RETAINED SHALL BE REMOVED COMPLETELY
FROM THE SITE BY THE GENERAL CONTRACTOR.
B THE GENERAL CONTRACTOR SHALL PROVIDE ALL TEMPORARY PARTITIONS AND TEMPORARY
DOORS AS INDICATED ON THIS DEMOLITION PLAN, OR AS DEEMED NECESSARY BY THE ARCHITECT
AND OWNER. THEY SHALL BE MAINTAINED, WITH ANY DAMAGE REPAIRED IMMEDIATELY, TO AVOID
MIGRATION OF DUST INTO THE ADJOINING AREAS.
C GENERAL CONTRACTOR TO VERIFY DUCTWORK OR PIPING PENETRATIONS THROUGH WALLS ABOVE
CEILING. IF PENETRATIONS OCCUR AND DUCTWORK OR PIPING 15 TO BE REMOVED OR RELOCATED,
FILL IN OPENINGS TO BE FLUSH WITH AND OF THE SAME MATERIAL AS THE SURROUNDING WALL.
p MAKE ALL DEMOLITION CLEAN AND COMPLETE AND IN A MANNER SUITABLE TO ACCEPT NEW
FINISHES AND OR SURFACES. REFER TO ARCHITECTURAL PLANS, SPECFICATION5, AND DETAILS FOR
SPECIFIC INFORMATION REGARDING APPLICATION OF NEW MATERIAL.
E SALVAGE ALL REMOVED DOORS AND FRAMES FOR OWNER, OR RE -USE IN THE SPACE. REPAIR
AND/OR RESTAIN DOORS FOR RE -USE IF CONDITION OF SUCH WILL ALLOW. VERIFY ANY QUESTION
WITH ARCHITECT.
GENERAL NOTESi
A ALL WORK 15 TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES,
ORDINANCES, RULES, REGULATIONS, AND STANDARDS, INCLUDNG, BUT NOT LIMITED TO: THE INDIANA
BUILDING CODE, THE INDIANA CODES, THE INDIANA FIRE CODES, THE AMERICANS WITH DISABILITIES
ACT (ADA), UNIVERSAL BUILDING CODE, AND APPLICABLE TRADE STANDARDS. ALL APPLICABLE
RULES AND REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITIONS.
B THE CONTRACTOR 15 RESPONSIBLE FOR FIELD VERIFYING ALL CONDITIONS AND DIMENSIONS PRIOR
TO THE START OF WORK. REPORT ANY DISCREPANCIES TO THE ARCHITECT/DESIGNER IMMEDIATELY.
C THE CONTRATOR 15 RESPONSIBLE FOR OBTAINING ALL LOCAL PERMITS REQUIRED FOR
COMPLETION OF THIS PROJECT,
D ALL WORK 15 TO BE COORDNATED BY THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT,
FINISH, SYSTEM OPERATION, AND FULL COMPLETION OF THE WORK INCLUDING SERVICE
REQUIREMENTS OF THE OWNER'S F.F.E.
E CONTRACTOR TO PROVIDE BUILDING STANDARD WINDOW BLINDS. RE -USE EXISTING WHERE
APPLICABLE.
F ALL DIMENSIONS ARE SHOU,N ON THE DRAWINGS. ANY DIMENSIONS NOT SHOWN OR DEEMED
QUE5TIOINA5LE ARE TO BE VERIFIED WITH THE ARCHITECT/DESIGNER DO NOT SCALE DIMENSIONS
ON THE DRAWINGS. ALL DIMENSIONS ARE TO THE FACE OF GYPSUM BOARD, MASONRY/CONCRETE
WALLS, OR CENTERLINE OF COLUMNS UNLESS NOTED OTHERWISE.
G CONTRACTOR IS TO SIGN EACH SHOP DRAWING SUBMITTAL CERTIFYING THAT THE SUBMITTAL HAS
BEEN REVIEWED, APPROVED, AND THAT THE CONTRACTOR COORDINATION HAS BEEN PERFORMED.
H DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION, ALL EXISTING EXITS, EXIT
LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED.
PREPARE ALL EXISTING WALLS AND FLOORS TO RECEIVE NEW FINISHES.
J FINISHED DOOR OPENINGS IN NEW PARTITIONS SHALL BE SET 4' FROM ADJACENT PERPENDICULAR
PARTITIONS, UNLESS NOTED OTHERWISE.
K PROVIDE BLOCKING IN WALLS TO ACCOMMODATE ALL CASEWORK AND WALL MOUNTED EQUIPMENT.
L ALL FINISH CARPENTRY IS TO BE COMPLETED IN STRICT ACCORDANCE WITH A.W.I. STANDARDS,
PREMIUM GRADE,
M ALL FIRE EXTINGUISHER CABINET LOCATIONS ARE TO BE COORDINATED WITH THE
ARCHITECT/DESIGNER AND THE LOCAL FIRE OFFICIALS PRIOR TO INSTALLATION.
N CONTRACTOR(S) SHALL PROVIDE ALL NECESSARY LABOR, MATERIALS, AND EQUIPMENT FOR THE
WORK N THESE DOCUMENTS, UNLESS CLEARLY NOTED 'NOT IN CONTRACT' (N.1Z.). EXISTING WORK
ADJACENT TO OR 1N THE AREA OF NEW WORK SHALL BE PROTECTED BY ALL SUITABLE MEANS
NECE88ARY TO PREVENT OR MINIMIZE DAMAGE. WHERE EXISTING WORK IS TO BE REMOVED OR
ALTERED, RESTORE ADJACENT FINISH TO ORIGINAL CONDITION. EXTEND/REFINISH ALL FRAMES,
BASE, AND TRIM WHERE CUTTING HAS EXPOSED ANY UNFINISHED SURFACES. REPAIR ANY DAMAGE
TO EXISTING WORK AND RESTORE TO ORIGINAL CONDITION.
O ALL DOOR 51ZE DIMENSIONS GIVEN ARE APPROXIMATE. DOOR SUPPLIER SHALL VERIFY EXACT
REQUIREMENTS.
P CONTRACTORS SHALL KEEP WORK AREAS AND ADJACENT PUBLIC CORRIDORS AND FACILITIES
FREE OF DEBRIS. MATERIALS STORED ON SITE ARE THE RESPONSIBILITY OF THE CONTRACTOR
AND SHALL BE STORED N A LOCATION APPROVED BY THE LANDLORD. PERSONAL RADIO$ SHALL
BE KEPT AT ACCEPTABLE VOLUME LEVELS IN OCCUPIED TENANT AREAS.
Q ALL PLUMBING ITEMS AND/OR EQUIPMENT ITEMS ARE TO BE COORDINATED AND VERIFIED WITH
INTERIOR ELEVATIONS PRIOR TO ROUGH -IN. ANY DISCREPANCIES SHALL BE COORDINATED WITH
THE ARCHITECT/DESIGNER
R COORDINATE WITH OWNER AND FACILITY STAFF PROJECT PHASING TO MINIMIZE DISRUPTION OF
EXISTING FACILITY SERVICES. PHASING TO INCLUDE ASSURANCE FOR CLEAN AIRFLOW, WRITTEN
NOTIFICATION OF INTERRUPTIONS, AND COMMUNICATION AUTHORITY. CONTRACTOR OWNER AND
FACILITY STAFF TO PLAN FOR PROCEDURES ON THE EFFECTS OF NOISE AND VIBRATION ON HUMAN
HEALTH AND SAFETY. THE RENOVATED AREAS SHALL BE ISOLATED FROM THE OCCUPIED AREAS
DURING ALL PHASES OF CONTRUCTION USING AIR -TIGHT BARRIERS, AND EXHAUST AIR FLOW SHALL
BE SUFFICIENT TO MAINTAIN NEGATIVE AIR PRESSURE IN THE CONSTRUCTION ZONE.
DOOR SCHEDULE NOTES E`
f
A. ALL HARDWARE TO BE LEVER TYPE (WHERE APPLICABLE) WITH BRUSHED ALUMINUM FINISH.
B. ALL HARDWARE SHALL COMPLY WITH INDIANA HANDICAPPED ACCESSIBILITY CODES.
C. BUILDING STANDARD DOOR FRAMES AND 6 -PANEL DOORS TO BE USED AT ALL DOOR LOCATIONS.
D. DOOR STAIN TO BE PROVIDED BY TENANT.
KEYNOTES:
OO ADJUSTABLE SHELVING TO BEGIN 42' AF -F., PROVIDED BY TENANT.
O CASEWORK WITH DROP-IN SINK, PROVIDED BY TENANT.
O WORKSUWACE INSTALLED OVER FRONT LOAD WASHER AND DRYER,
WALL CABINETS ABOVE, TO BE PROVIDED BY TENANT.
O BUILT-IN DISPLAY CABINET TO BE PROVIDED BY TENANT.
O SHOWER UNIT PROVIDED BY TENANT. SEE SPECIFICATIONS FOR ELECTRICAL
AND/OR PLUMBING REQUIREMENTS.
O ALIGN NEW PARTITION WITH EXISTING.
0
0
0
3(
,40
1
A R C H I T E C T S
PL A N N E R S
1132 S. RANGEUNE RD. SUITE 202
CARMEL, IN 46032
2-N\_ ARCPTECTUIRAL FLAN
Al
V
DOOR/HARDWARE SCHEDULE
FLOOR PLAN WALL SYMBOLS LEGEND
DOOR
DIMENSIONS
�4
----- EXISTING WALL PARTITION TO BE DEMOLISHED.
7TTTTT EXISTING WALL PARTITION TO REMAIN.
NEW WALL PARTITION 25 GA - 2 1/2' METAL STUDS 0 24' O.G. WITH 5/5' GYPSUM
WALLBOARD ON EACH SIDE, TERMINATED AT THE CEILING GRID, WITH
INSULATION IN STUD CAVITIES AND ABOVE WALL HORIZONTALLY 2'-0' IN EACH
DIRECTION.
TYPE
GENERAL NOTESi
A ALL WORK 15 TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES,
ORDINANCES, RULES, REGULATIONS, AND STANDARDS, INCLUDNG, BUT NOT LIMITED TO: THE INDIANA
BUILDING CODE, THE INDIANA CODES, THE INDIANA FIRE CODES, THE AMERICANS WITH DISABILITIES
ACT (ADA), UNIVERSAL BUILDING CODE, AND APPLICABLE TRADE STANDARDS. ALL APPLICABLE
RULES AND REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITIONS.
B THE CONTRACTOR 15 RESPONSIBLE FOR FIELD VERIFYING ALL CONDITIONS AND DIMENSIONS PRIOR
TO THE START OF WORK. REPORT ANY DISCREPANCIES TO THE ARCHITECT/DESIGNER IMMEDIATELY.
C THE CONTRATOR 15 RESPONSIBLE FOR OBTAINING ALL LOCAL PERMITS REQUIRED FOR
COMPLETION OF THIS PROJECT,
D ALL WORK 15 TO BE COORDNATED BY THE GENERAL CONTRACTOR TO ASSURE ADEQUATE FIT,
FINISH, SYSTEM OPERATION, AND FULL COMPLETION OF THE WORK INCLUDING SERVICE
REQUIREMENTS OF THE OWNER'S F.F.E.
E CONTRACTOR TO PROVIDE BUILDING STANDARD WINDOW BLINDS. RE -USE EXISTING WHERE
APPLICABLE.
F ALL DIMENSIONS ARE SHOU,N ON THE DRAWINGS. ANY DIMENSIONS NOT SHOWN OR DEEMED
QUE5TIOINA5LE ARE TO BE VERIFIED WITH THE ARCHITECT/DESIGNER DO NOT SCALE DIMENSIONS
ON THE DRAWINGS. ALL DIMENSIONS ARE TO THE FACE OF GYPSUM BOARD, MASONRY/CONCRETE
WALLS, OR CENTERLINE OF COLUMNS UNLESS NOTED OTHERWISE.
G CONTRACTOR IS TO SIGN EACH SHOP DRAWING SUBMITTAL CERTIFYING THAT THE SUBMITTAL HAS
BEEN REVIEWED, APPROVED, AND THAT THE CONTRACTOR COORDINATION HAS BEEN PERFORMED.
H DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION, ALL EXISTING EXITS, EXIT
LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED.
PREPARE ALL EXISTING WALLS AND FLOORS TO RECEIVE NEW FINISHES.
J FINISHED DOOR OPENINGS IN NEW PARTITIONS SHALL BE SET 4' FROM ADJACENT PERPENDICULAR
PARTITIONS, UNLESS NOTED OTHERWISE.
K PROVIDE BLOCKING IN WALLS TO ACCOMMODATE ALL CASEWORK AND WALL MOUNTED EQUIPMENT.
L ALL FINISH CARPENTRY IS TO BE COMPLETED IN STRICT ACCORDANCE WITH A.W.I. STANDARDS,
PREMIUM GRADE,
M ALL FIRE EXTINGUISHER CABINET LOCATIONS ARE TO BE COORDINATED WITH THE
ARCHITECT/DESIGNER AND THE LOCAL FIRE OFFICIALS PRIOR TO INSTALLATION.
N CONTRACTOR(S) SHALL PROVIDE ALL NECESSARY LABOR, MATERIALS, AND EQUIPMENT FOR THE
WORK N THESE DOCUMENTS, UNLESS CLEARLY NOTED 'NOT IN CONTRACT' (N.1Z.). EXISTING WORK
ADJACENT TO OR 1N THE AREA OF NEW WORK SHALL BE PROTECTED BY ALL SUITABLE MEANS
NECE88ARY TO PREVENT OR MINIMIZE DAMAGE. WHERE EXISTING WORK IS TO BE REMOVED OR
ALTERED, RESTORE ADJACENT FINISH TO ORIGINAL CONDITION. EXTEND/REFINISH ALL FRAMES,
BASE, AND TRIM WHERE CUTTING HAS EXPOSED ANY UNFINISHED SURFACES. REPAIR ANY DAMAGE
TO EXISTING WORK AND RESTORE TO ORIGINAL CONDITION.
O ALL DOOR 51ZE DIMENSIONS GIVEN ARE APPROXIMATE. DOOR SUPPLIER SHALL VERIFY EXACT
REQUIREMENTS.
P CONTRACTORS SHALL KEEP WORK AREAS AND ADJACENT PUBLIC CORRIDORS AND FACILITIES
FREE OF DEBRIS. MATERIALS STORED ON SITE ARE THE RESPONSIBILITY OF THE CONTRACTOR
AND SHALL BE STORED N A LOCATION APPROVED BY THE LANDLORD. PERSONAL RADIO$ SHALL
BE KEPT AT ACCEPTABLE VOLUME LEVELS IN OCCUPIED TENANT AREAS.
Q ALL PLUMBING ITEMS AND/OR EQUIPMENT ITEMS ARE TO BE COORDINATED AND VERIFIED WITH
INTERIOR ELEVATIONS PRIOR TO ROUGH -IN. ANY DISCREPANCIES SHALL BE COORDINATED WITH
THE ARCHITECT/DESIGNER
R COORDINATE WITH OWNER AND FACILITY STAFF PROJECT PHASING TO MINIMIZE DISRUPTION OF
EXISTING FACILITY SERVICES. PHASING TO INCLUDE ASSURANCE FOR CLEAN AIRFLOW, WRITTEN
NOTIFICATION OF INTERRUPTIONS, AND COMMUNICATION AUTHORITY. CONTRACTOR OWNER AND
FACILITY STAFF TO PLAN FOR PROCEDURES ON THE EFFECTS OF NOISE AND VIBRATION ON HUMAN
HEALTH AND SAFETY. THE RENOVATED AREAS SHALL BE ISOLATED FROM THE OCCUPIED AREAS
DURING ALL PHASES OF CONTRUCTION USING AIR -TIGHT BARRIERS, AND EXHAUST AIR FLOW SHALL
BE SUFFICIENT TO MAINTAIN NEGATIVE AIR PRESSURE IN THE CONSTRUCTION ZONE.
DOOR SCHEDULE NOTES E`
f
A. ALL HARDWARE TO BE LEVER TYPE (WHERE APPLICABLE) WITH BRUSHED ALUMINUM FINISH.
B. ALL HARDWARE SHALL COMPLY WITH INDIANA HANDICAPPED ACCESSIBILITY CODES.
C. BUILDING STANDARD DOOR FRAMES AND 6 -PANEL DOORS TO BE USED AT ALL DOOR LOCATIONS.
D. DOOR STAIN TO BE PROVIDED BY TENANT.
KEYNOTES:
OO ADJUSTABLE SHELVING TO BEGIN 42' AF -F., PROVIDED BY TENANT.
O CASEWORK WITH DROP-IN SINK, PROVIDED BY TENANT.
O WORKSUWACE INSTALLED OVER FRONT LOAD WASHER AND DRYER,
WALL CABINETS ABOVE, TO BE PROVIDED BY TENANT.
O BUILT-IN DISPLAY CABINET TO BE PROVIDED BY TENANT.
O SHOWER UNIT PROVIDED BY TENANT. SEE SPECIFICATIONS FOR ELECTRICAL
AND/OR PLUMBING REQUIREMENTS.
O ALIGN NEW PARTITION WITH EXISTING.
0
0
0
3(
,40
1
A R C H I T E C T S
PL A N N E R S
1132 S. RANGEUNE RD. SUITE 202
CARMEL, IN 46032
2-N\_ ARCPTECTUIRAL FLAN
Al
V
DOOR/HARDWARE SCHEDULE
d
DOOR
DIMENSIONS
�4
TYPE
CONST.
MAT'L.
FINISH
HDWR.
REMARKS }
WID11
MT.
I THK.
NO.
DEMOLITION &
a
ARCH. PLANS
.
P CUEcr-
.
101
3'-0'
6--a-11-3/4'
EXISTING TO REMAIN
103
3'-0'
6'-i3'
1-3/4'
FLUSH
SOLID CORE
BIRCH
STAINED
P, C
FRENCH DOOR
104
3'-0'
6'-8'
1-3/4'
FLUSH
SOLID CCO1RE
BIRCH
STAINED
LS
d '
W
C
d 0 } O,.
'0
V
C6 a
105
3'-0"
N
L
C
FLUSH
SOLID CORE
-1BIRCH
STAINED
LS
~ H c
O
Z
� std- 0.W.
}
-
a
)Oro
3'-0"
6'-S'
1-3/4'
FLUSH
SOLID CORE
BIRCH
STAINED
LS
d
O_
C
U
+"
o c y
10-1
3'-0
6'-8'
i-3/4'
FLUSH
SOLID CORE
BIRCH
STAINED
LS
3
t
o o v
d
W
X
6
C
1093'-0'
6'-6'
1-3/4'
FLUSH
SOLID CORE
BIRCH
STAINED
BPL
T
ZCM
�a
(L
C .= 0 .. `
H
V)
> i
111
3'-0'
6'-8'
1-3/4'
FLUSH
SOLID CORE
BIRCH
STAINED
P
v
m I
112
3'-0'
6'-8'
1-3/4'
FLUSH
SOLID CORE
BIRCH
STAINED
BPL
113
(2) 1'-6'
6'-i3'
1-3/4'
FLUSH
SOLID CORE
BIRCH
STAINED
F'
114
2'-6"
6'-S'
1-3/4'1
FLUSH
SOLID CORE
BIRCH
i STAINED
LS
LEGEND: P = PASSAGE, C = CLOSER, LS= LOCKSET, BPL =
� SECOND FLOOR KEiPLAN
� SCALE: NONE
CONSTRUCTION DOCUMENTS
ssas�s�ra�Martaa��rslr,�
R R.%%
JP G1 S
No. 4184
= T STATE OF T ,�
�, ✓'� PYA `-�'D i A{'tP � `\�.
7
i
18 SEP
SCALE; 1/4001
DRwwN= MLE/DCZ
REVIS ONS-
All ideas, designs, and plane indicated or
W L
�4
Mftk Design. Contractors d" VsWy and
V)
be .tMpnsible for all dta mmiead' h the
)ab 00.. AN ftW r Wrod, except for
t
+ rn0
d;o
DEMOLITION &
a
ARCH. PLANS
.
P CUEcr-
-
}mo "
o°
�
V
H lL C 4
�d cry
L
Q
x
L
'O
N C
E y 'W�1
W
C
d 0 } O,.
'0
V
C6 a
N
L
C
L 0'2
d
.gyp
L
4-
~ H c
O
Z
� std- 0.W.
}
d N
o u
�
O_
C
U
+"
o c y
g
V
40-u .c
y v <
d
� � V
oU
t
o o v
d
W
X
6
C
ZCM
�a
(L
C .= 0 .. `
H
V)
d + + o
N o -0
Q
.n
U
L + C
°
LL,
�.
v
4-
H d N
1
� SECOND FLOOR KEiPLAN
� SCALE: NONE
CONSTRUCTION DOCUMENTS
ssas�s�ra�Martaa��rslr,�
R R.%%
JP G1 S
No. 4184
= T STATE OF T ,�
�, ✓'� PYA `-�'D i A{'tP � `\�.
7
i
18 SEP
SCALE; 1/4001
DRwwN= MLE/DCZ
REVIS ONS-
All ideas, designs, and plane indicated or
represented by these dravium are owned
by, and the property of brand
Mftk Design. Contractors d" VsWy and
be .tMpnsible for all dta mmiead' h the
)ab 00.. AN ftW r Wrod, except for
uses expressly permitted in writing.
DRAWING NAME
DEMOLITION &
ARCH. PLANS
.
P CUEcr-
71
41
V_
4'— 3
DD Q,
42' P.
GPA.
42' APP.
14
1 ELECTRICAL FLAN
AZ 5CALE:1/4" =1'-0"
O
ELECTRICAL LEGEND
0
OTHERWISE.
42' APP.
c'v
I1
H COLOR FOR SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES SHALL BE PROVIDED BY
N
VW�U SPECIFICATIONS FOR DETAILS
lf')
uIA". ! o
GROUND FAULT INTERRUPTER
l
I ALL DIMENSIONS SHOWN ARE TO CENTERLINE OF OUTLETS OR GROUPS OF OUTLETS, UNLESS NOTED
SINGLE POLE SWITCH
Cu
DIRECTIONAL RECESSED
OTHERWISE.
I
DIMMER SWITCH
0 SPEAKER SYSTEM CONNECTION
LIGHT FIXTURE
co
BAND SYSTEM
C1
WALL -MOUNTED FIXTURE,
MOUNTED AT 68' AFF
- _
EXHAUST FAN W/ LIGHT
TRANSMISSION.
2 X 2 LAY -IN GRID
OS
SPEAKER
SUSPENSION SYSTEM
®
CEILIWj-MTD. EXIT LIGHT
C�
K ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE G4NGED, THEY SHALL BE
INSTALLED WITH A MINIMUM DISTANCE BETWEEN UNITS. -- —�— —�---
L PROVIDE EMERGENCY STROBES AND HORNS AS REQUIRED BY STATE AND LOCAL BUILDING CODES.
v Y_
3
'v
M DO NOT SCALE DRAWINGS. ALL DIMENSIONS GIVEN ARE TO BE ADHERED TO, UNLESS FIELD CONDITIONS
DEEM OTHERWISE. ANY CONFLICTS THAT MAY EXIST W/ NEW CONSTRUCTION MU5? BE REVIEWED BY
CD
_
ARCHITECT PRIOR TO CONSTRUCTION OF WORK. DO NOT CIRCUMVENT DIMENSIONS BY ATTACHING
O
L
m
c
0
/
a�
C_
c
b U
a
C_
/
<n
W
O
a:
CL
w
6-i
A
I
7'_2"
1 I
3. 0„
4'-0"
CENTER ARCHWAY ON WALL.
i,:
3 ARGHL A* E VAT I ON
A2 SCALE' i/4`=?' -0'
/ 2
O
P
- S'-4 3/4 -
_L SCONCE
TENANT
— ` •
QWASHER/ DRYER 1 -LOOK -UP TO BE INSTALLED, COORDINATE WITH APPLIANCE SF'EGS PROVIDED BY
TENANT.
OCASEWORK TO RECEIVE UNDER -CABINET LIGHTING. SWITCHING FOR THE LIGHTING TO BE LOCATED
BETWEEEN UPPER AND LOWER CABINETS. LIGHTING SPECS TO BE PROVIDED BY TENANT.
O / �
GENERAL ELECTRICAL PLAN NOTES
A THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR, MATERIAL, EQUIPMENT, AND Lp
CONTRACTORS SERVICES NECESSARY TO COMPLETE INSTALLATION OF SYSTEMS REQUIRED IN FULL`
CONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE FINISHED JOB SHALL BE FUNCTIONAL
AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR A COMPLETE SYSTEM. ----- - —
8 ALL MATERIAL AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE AND LOCAL CODES, I I Y \
ORDINANCES, UTILITY COMPANY REGULATIONS AND NATIONALLY ACCEPTED CODES AND STANDARDS.
THE ELECTRICAL CONTRACTOR WILL BEAR ALL COSTS ARISING IN CORRECTING ANY NON-COMPLIANCE -- - WITH THE REQUIRMENT5 OF APPLICABLE CODES.
i I m
C THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/DESIGNER OF ANY DISCREPANCIES r
BETWEEN THE CONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO CONSTRUCTION.
D ELECTRICAL CONTRACTOR TO COORDINATE SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTS OF
TENANT'S AS SPECIFICALLY INDICATED ON DRAWINGS. VERIFY ACTUAL REQUIREMENTS WITHL--
ARCHITECT/DESIGNER PRIOR TO INSTALLATION. J
E ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AT TELEPHONE/DATA LOCATIONS AS
INDICATED ON PLANS. COMPLETE TELEPHONE/DATA SYSTEMS (MATERIAL AND LABOR) ARE PROVIDED
BY THE TENANT UNLESS NOTED OTHERWISE. 4
F ELECTRICAL CONTRACTOR SHALL COORDINATE ANY ELECTRICAL OR LIGHTING REQUIREMENTS OF �
MILLWORK WITH ARCHITECTURAL WOODWORK CONTRACTOR AS NECESSARY.
G ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED 15' AFF. TO CENTERLINE OF OUTLET, UNLESS NOTED
ELECTRICAL LEGEND
OTHERWISE.
42' APP.
r�
I1
H COLOR FOR SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES SHALL BE PROVIDED BY
j
VW�U SPECIFICATIONS FOR DETAILS
TENANT.
uIA". ! o
/ 2
O
P
- S'-4 3/4 -
_L SCONCE
TENANT
— ` •
QWASHER/ DRYER 1 -LOOK -UP TO BE INSTALLED, COORDINATE WITH APPLIANCE SF'EGS PROVIDED BY
TENANT.
OCASEWORK TO RECEIVE UNDER -CABINET LIGHTING. SWITCHING FOR THE LIGHTING TO BE LOCATED
BETWEEEN UPPER AND LOWER CABINETS. LIGHTING SPECS TO BE PROVIDED BY TENANT.
O / �
GENERAL ELECTRICAL PLAN NOTES
A THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR, MATERIAL, EQUIPMENT, AND Lp
CONTRACTORS SERVICES NECESSARY TO COMPLETE INSTALLATION OF SYSTEMS REQUIRED IN FULL`
CONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE FINISHED JOB SHALL BE FUNCTIONAL
AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR A COMPLETE SYSTEM. ----- - —
8 ALL MATERIAL AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE AND LOCAL CODES, I I Y \
ORDINANCES, UTILITY COMPANY REGULATIONS AND NATIONALLY ACCEPTED CODES AND STANDARDS.
THE ELECTRICAL CONTRACTOR WILL BEAR ALL COSTS ARISING IN CORRECTING ANY NON-COMPLIANCE -- - WITH THE REQUIRMENT5 OF APPLICABLE CODES.
i I m
C THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/DESIGNER OF ANY DISCREPANCIES r
BETWEEN THE CONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO CONSTRUCTION.
D ELECTRICAL CONTRACTOR TO COORDINATE SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTS OF
TENANT'S AS SPECIFICALLY INDICATED ON DRAWINGS. VERIFY ACTUAL REQUIREMENTS WITHL--
ARCHITECT/DESIGNER PRIOR TO INSTALLATION. J
E ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AT TELEPHONE/DATA LOCATIONS AS
INDICATED ON PLANS. COMPLETE TELEPHONE/DATA SYSTEMS (MATERIAL AND LABOR) ARE PROVIDED
BY THE TENANT UNLESS NOTED OTHERWISE. 4
F ELECTRICAL CONTRACTOR SHALL COORDINATE ANY ELECTRICAL OR LIGHTING REQUIREMENTS OF �
MILLWORK WITH ARCHITECTURAL WOODWORK CONTRACTOR AS NECESSARY.
G ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED 15' AFF. TO CENTERLINE OF OUTLET, UNLESS NOTED
ELECTRICAL LEGEND
OTHERWISE.
LEGEND
8 110 VOLT DUPLEX WALL RECEPTACLE
I1
H COLOR FOR SWITCH PLATES, MONUMENTS, AND ELECTRICAL COVER PLATES SHALL BE PROVIDED BY
j
VW�U SPECIFICATIONS FOR DETAILS
TENANT.
GROUND FAULT INTERRUPTER
l
I ALL DIMENSIONS SHOWN ARE TO CENTERLINE OF OUTLETS OR GROUPS OF OUTLETS, UNLESS NOTED
SINGLE POLE SWITCH
AFF ABOVE FINISH FLOOR
DIRECTIONAL RECESSED
OTHERWISE.
I
DIMMER SWITCH
0 SPEAKER SYSTEM CONNECTION
LIGHT FIXTURE
J DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS. STAGGER AS REQUIRED TO MINIMIZE SOUND ----- -
BAND SYSTEM
WALL -MOUNTED FIXTURE,
MOUNTED AT 68' AFF
- _
EXHAUST FAN W/ LIGHT
TRANSMISSION.
2 X 2 LAY -IN GRID
OS
SPEAKER
SUSPENSION SYSTEM
®
CEILIWj-MTD. EXIT LIGHT
C�
K ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE G4NGED, THEY SHALL BE
INSTALLED WITH A MINIMUM DISTANCE BETWEEN UNITS. -- —�— —�---
L PROVIDE EMERGENCY STROBES AND HORNS AS REQUIRED BY STATE AND LOCAL BUILDING CODES.
v Y_
WALL MOUNTED LIGHT BAR MOUNTED
--
M DO NOT SCALE DRAWINGS. ALL DIMENSIONS GIVEN ARE TO BE ADHERED TO, UNLESS FIELD CONDITIONS
DEEM OTHERWISE. ANY CONFLICTS THAT MAY EXIST W/ NEW CONSTRUCTION MU5? BE REVIEWED BY
_
ARCHITECT PRIOR TO CONSTRUCTION OF WORK. DO NOT CIRCUMVENT DIMENSIONS BY ATTACHING
RECEPTACLES t0 NEAREST STUD. _
N THESE ELECTRICAL DRAWINGS REFLECT LOCATIONS ONLY. CONSULT WITH ELECTRICAL ENGINEER FOR -(Y}
FURTHER TECHNICAL INFORMATION. —
O ELECTRICAL DATA OUTLET LOCATIONS TO BE COORDINATED WITH TENANT PRIOR TO ROUGH -IN. ALL `----
LOCATI" TO BE VERIFIED WITH FURNITURE PLACEMENT. -
II
II
I
I
II
GENERAL REFLECTED CEILING PLAN NOTESi
A PAINT EX15TMG GYPSUM BOARD BULKHEADS TO MATCH CEILING AS REQUIRED, UNLE55 NOTED OTHERWISE.
B RE"O /E EXISTING SWITCHES THAT ARE NOT RE -USED. REMOVE CONDUIT AND j!RING BACK TO NEAREST
BASE 5U LOWx JUNCTION BOX. PATCH AND REPAIR WALL FOR NEW FINISH.
C PROVIDE FIRE DAMPERS AT FIRE -RATED PARTITIONS.
D REFER TO ELECTRICAL PLAN FOR LIGHTING SCHEDULE/SPECIFICATIONS.
E THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHT AND
CEILING PLENUM CONDITIONS FOR C L_ E: 4RANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO
ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE
ARC,HITECT/DESIGNER'S ATTENTION IMMEDIATELY, PRIOR TO THE COMMENCEMENT OF ANY WORK
F CEILING IN ALL AREAS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS, AND STATE AND LOCAL BUILDING CODES.
G UNLESS NOTED OTHERWISE, CEILING HEIGHT THROUGHOUT THE SPACE IS xxxxxx AFF.
H ALL DIMENSIONS ARE FROM CENTERLINE TO CENTERLINE OF FIXTURES.
EXISTING CEILING GRID AND ACOUSTICAL TILE TO REMAIN, UNLESS NOTED OTHERWISE. CONTRACTOR TO
REMOVE AND REPLACE ANY EXISTING CEILING TILES AND CEILING GRID THAT 15 BROKEN, CHIPPED, OR
PUNCTURED WITH NEW TO MATCH EXISTING.
J ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH
&'-S' FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE.
4 Fi�ENCH DOOIR ELEVATION
A2 F
SCALE: 1/4' =1' -m'
2 CEILING FDL4N
A2 JSCALE:1/4'=1'-m'
fi
M
a
ELECTRICAL LEGEND
[:REFLECTED CEILING PLAN
LEGEND
8 110 VOLT DUPLEX WALL RECEPTACLE
,}DEQ SPECIAL RECEPTACLE, SEE EQUIPMENT
VW�U SPECIFICATIONS FOR DETAILS
6G.F.I, DUPLEX WALL RECEP. W/ 110 VOLT ON
GROUND FAULT INTERRUPTER
2 X 4 FLUORESCENT
LIGHT - RECESSED
® TELEPHONE JACK
SINGLE POLE SWITCH
AFF ABOVE FINISH FLOOR
DIRECTIONAL RECESSED
® TELEPHONE/DATA WALL RECEPTACLE
DIMMER SWITCH
0 SPEAKER SYSTEM CONNECTION
LIGHT FIXTURE
2 CEILING FDL4N
A2 JSCALE:1/4'=1'-m'
fi
M
a
SLM i00
INDMAPOUS,
INDIANA 46290
(VOlm
317-573-=
(F'A)O
;317-573-7130
A R C H IT E C T S
P L A N N E R S
1132 S. RANGEUNE RD. SUITE 202
CARMEL, IN 46032
mmol
qY
O
L)
G s T C, \
_ yy No. 4184yy
T STATE OF �(T`
DATE 18 SEP 01
SCALE; 1/4••1'-0'
DRAWN= MLE/DCZ ,'
1XI
r
An WWA 1 11161r and pine indieaad er
repmented by bees drawtnp an owned
by, and the property of Hillenbrand
Mitach Daaisa. Contractors shall verify and
be responsible for all dimensions on the
5ECOi I iyo ������ lob site. All rights reserved, except for
u
[t��j `[VJ ps expretely permitted in writing.
DRAWING T4: 4.
SCALE: �!
ELECTRICAL
& CEILING PLANS
PROJEC"I` SHEET
C 0 T R U C T 10 D 0 C U _M NTS
01688 A2
[:REFLECTED CEILING PLAN
LEGEND
2 X 4 FLUORESCENT
LIGHT - RECESSED
SINGLE POLE SWITCH
DIRECTIONAL RECESSED
$D
DIMMER SWITCH
T
LIGHT FIXTURE
RECESSED LIGHT FIXTUREg
BAND SYSTEM
WALL -MOUNTED FIXTURE,
MOUNTED AT 68' AFF
®
EXHAUST FAN W/ LIGHT
2 X 2 LAY -IN GRID
OS
SPEAKER
SUSPENSION SYSTEM
®
CEILIWj-MTD. EXIT LIGHT
C�
EMERGENCY LIGHTING
v Y_
WALL MOUNTED LIGHT BAR MOUNTED
ABOVE MIRROR AT T-6' AFF
SLM i00
INDMAPOUS,
INDIANA 46290
(VOlm
317-573-=
(F'A)O
;317-573-7130
A R C H IT E C T S
P L A N N E R S
1132 S. RANGEUNE RD. SUITE 202
CARMEL, IN 46032
mmol
qY
O
L)
G s T C, \
_ yy No. 4184yy
T STATE OF �(T`
DATE 18 SEP 01
SCALE; 1/4••1'-0'
DRAWN= MLE/DCZ ,'
1XI
r
An WWA 1 11161r and pine indieaad er
repmented by bees drawtnp an owned
by, and the property of Hillenbrand
Mitach Daaisa. Contractors shall verify and
be responsible for all dimensions on the
5ECOi I iyo ������ lob site. All rights reserved, except for
u
[t��j `[VJ ps expretely permitted in writing.
DRAWING T4: 4.
SCALE: �!
ELECTRICAL
& CEILING PLANS
PROJEC"I` SHEET
C 0 T R U C T 10 D 0 C U _M NTS
01688 A2