Loading...
HomeMy WebLinkAbout33Beam/Column Sizes Beam/Column Flange Thk. Flange Width Web Thk. Depth CONNECTION END 1 CONNECTION END 2 Qty. Size Qty. Size MBX001 .25 5 .1875 21 5 1" X 2 1/2" 5 1" X 2 3/4" M13XO02 .25 5 .1875 21 5 1" X 2 3/4" 5 1" X 2 3/4" MBX003 .625 8 .25 24 6 1" X 2 3/4" 6 1" X 2 3/4" MBX004 .5 6 .1875 24 5 1" X 2 3/4" 5 1" X 2 3/4" MBX005 .25 5 .1875 21 5 1" X 2 3/4" 5 1" X 2 1/2" MBX006 .3125 6 .25 24 6 3/4" X 2" 2 3/4" X 2" MBX007 .3125 6 .25 24 2 3/4" X 2" 6 3/4" X 2" MBX008 .25 6 .25 24 6 3/4" X 2" 12 3/4" X 2" MBX009 .5 6 .25 24 4 3/4" X 2" 6 3/4" X 2" MBX010 .5 7 .25 24 6 3/4" X 2" 6 3/4" X 2" MBX011 .5 10 .25 24 6 1" X 2 3/4" 6 1" X 2 3/4" MBX012 .3125 6 .1644 24 6 3/4" X 2" 6 3/4" X 2" MBX013 .5 6 .25 24 6 1" X 2 1/2" 6 1" X 2 1/2" MBX014 .1875 5 .1644 10 2 3/4" X 2" 2 3/4" X 2" MBX015 .1345 5 .1345 10 2 3/4" X 2" 2 3/4" X 2" MBX016 .1345 5 .1345 10 2 3/4" X 2" 2 3/4" X 2" 1XP07203190 I � � I ! I rl MBX005 � I � ~ I m ' I ! i �\ ** MBX009 MBX004 ** I I CID ** W I MBX010� N ■ In MBX008 � �! a , m 0 ** DENOTES END 1 Ln w ** MBX011 i MBX003 ! ! rN I MBX007 N I MBX002 i I MBX006 - � I s I i r MBX001 N � I i I ** ** I I hi 29'-6" -30'-1" 30'-1" 123'-0" MEZZANINE BEAM LAYOUT 1 2'-2" Dimension Key Finished Floor Elevation = 100-0" (Unless Notel Otherwise) 1. CONCRETE, GROUT, ANCHOR BOLTS, AND ANY OTHER EMBEDDED ITEMS ARE THE VP ENGINEER'S SEAL APPLIES Building Code: 97UBC THIS DRAWING, INCLUDING THE INFORMATION ERE N, TO BE FURNISHED BY OTHERS ONLY TO THE WORK PRODUCT OFREMAINS THE PROPERTY OF VP BUILDINGS. Live L.(Not Reducible) 20.00 psf VP Buildings, inc. 2. ANCHOR BOLT DIAMETERS WERE DETERMINED BY ALLOWABLE SHEAR AND TENSION VP AND DESIGN AND PERFORMANCEPROVIDED SOLELY FOR ERECTING THE BU LDING, REQUIREMENTS SPECIFIED BY VP, Coll. Load:Gravity 5.00, Uplift 0.00 psf DESCRIBED IN THE APPLICABLE PURCHASE OR ERA D 3200 Pia MEZZANINE BEAM LAYOUT PER AI SC SPECIFICATIONS (FY = 36 KSI). ANCHOR BOLT LENGTH, EFFECTS Wind Speed: 71.00 m SHALL NOT BE MODIFIED, REPRODUCED OR US D F0� Players Club Circle Memphis TN 38125 THE VP ENGINEER'S SEAL DOES P ph ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN OF EMBEDDED ANCHOR BOLT EDGE DIMENSIONS AND METHOD OF TRANSFERRING NOT APPLY TO THE PERFORMANCE Wind Exposure B APPROVAL OF VP BUILDINGS, REv DATE By DESCRIPTION BUILDER FORCES FROM ;ANCHOR BOLTS TO FOOTINGS ARE TO BE DETERMINED BY OTHERS. OR DESIGN OF ANY OTHER PRODUCT Ground Snow: 20.00 , Roof Snow: 20.00 psf __ Systems Builders, Inc. THE GENERAL CONTRACTOR AND/OR ERECTO IS ELY CUSTOMER 3. DESIGN LOADS AND REACTIONS ARE FURNISHED ON OTHER DOCUMENTS. OR COMPONENT FURNISHED BY VP Snow Exposure Category: 3 � Capitol Construction 4. FOUNDATION MUST BE LEVEL, SQUARE AND SMOOTH. ANCHOR BOLTS MUST BE EXCEPT TO ANY DESIGN OR PER- RESPONSIBLE FOR ACCURATE, GOOD QUALITY NORKMANSHI FORMANCE REQUIREMENTS Seismic: Zone 1 IN ERECTING THIS BUILDING IN CONFORMANCE WITH HIS LOCATION ACCURATELY PLACED AS SHOWN ON THIS DRAWING OR STEEL WILL NOT FIT. Building Use Standard occupancies DRAWING, DETAILS REFERENCED IN THIS DR NG, Indianapolis, Indiana SPECIFIED BY VP. P ALL APPLICABLEVP ERECTION GUIDES, PROJECT AND INDUSTRY STANDARDS PERTAINING TO PR PER OH0111248-OlOElDWGS ERECTION, INCLUDING THE CORRECT USE OF EMPORARY SUILDeasPott BRACING. NTS FILENAME 10/19/2001 14:42:08 OH0111248-01OE1DWGS.vpc .......... TER�; e PEI 00��� c T •NO I ANP•: t�/0NAL �..# (3/,241 OH0111248-01 DATE 10/2/2001 P BUILDINGS D-N/CHECK VARCO-PRUDEN GJS GJS VPC VERSION PAGE 2.6 1 PS -2