HomeMy WebLinkAbout41OPart Mark Key
1 GCC07208,4
2 JBC1
3 GFA106
Non -Std Secondary Part
Schedule
1 2'-2"
Part
Thick,
Depth
Lap
00163102017
0.0651)
8 1/2"
1'-0"
003G3209011
0.1200
8 1/2"
1'-0"
00463209017
0.0590
8 1/2"
1'-0"
6
1
i---------------------------------------------------------------------------------
40G3203417
-------------------------- —40G3203417
i
0 31
i
4063203417
�40G32031<17(�yp.)
i
I o6gp
CV V lO
40G3106417(Typ.) 46G3L03411 00363209011
4063203411
�I j
0160907017 DH1008017 1Z
0163005015 0 0)1G�102017 ( yp )
o 2L -01G0903017
'T o I 00463209017 T
h
1
i
-77777
Not by VP - Masonry
/f777
// // , 063/ / //� /� / / /
l'-2
'-10 1/2" 10'-81,- 9'-6 1/2"
30'-1" 3011-1"I 29'-6"
123' -0" -
SECONDARY ELEVATION AT A
3 2'-10 3/4"
2 4'-3.3/4"
1 2'-2"
O[Dimension.Key
VP Ref: Shape Name = Capitol, Wall = 2
1. UNLESS NOTED, USE 1/2 DIAMETER A-325 BOLTS FOR GIRT LAP,
THE VP ENGINEER'S SEAL APPLIES
Building Code: 97UBC
THIS DRAWING, INCLUDING THE INFORMATION
GIRT TO FRAME, FLANGE BRACE TO FRAME, FLANGE BRACE TO GIRT,
ONLY TO THE WORK PRODUCT OFREMAINS
Live Load: (Not Reducible)
THE PROPERTY OF VP BUILDINGS.
JAMB AND HEADER CONNECTIONS. SEE JOB DETAILS FOR BOLT LENGTHS.
VP AND DESIGN AND PERFORMANCE
20.00 psf
IT IS PROVIDED SOLELY FOR ERECTING THE BU
2. WIND AND FLANGE BRACING ARE AN INTEGRAL PART OF THE WALL STRUCTURAL
REQUIREMENTS SPECIFIED BY VP.
Coll. Load:Gravity 5.00, Uplift 0.00 psf
DESCRIBED IN THE APPLICABLE PURCHASE OR
THE VP ENGINEER'S SEAL DOES
Wind Speed: 71.00 mph
SHALL NOT BE MODIFIED, REPRODUCED OR US
SYSTEM AND SHOULD BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL
NOT APPLY TO THE PERFORMANCE
Wind Ex
Exposure: B
ANY OTHER PURPOSE WITHOUT PRIOR WRITTE
AND ROOF SHEETS. REMOVAL OR ALTERATION OF WALL BRACING WITHOUT
OR DESIGN OF ANY OTHER PRODUCT
Ground Snow: 20.00 Roof
APPROVAL OF VP BUILDINGS.
PRIOR AUTHORIZATION IS PROHIBITED.
OR COMPONENT FURNISHED BY VP
, Snow: 20.00 psf
Snow Exposure Category: 3
THE GENERAL CONTRACTOR AND/ORERECTOF
EXCEPT TO ANY DESIGN OR PER-
Seismic: Zone 1
RESPONSIBLE FOR ACCURATE, GOOD QUALITY
FORMANCE REQUIREMENTS
IN
SPECIFIED BY VP.
Building Use: Standard occupancies
g P
DRAWINTINGTHISBUILDINGINCONFORMANCE
DRAWING, DETAILS REFERENCED IN THIS DRAB
ALLAPPLICABLE VPERECTION GUIDES,
AND INDUSTRY STANDARDS PERTAINING TO PR
ERECTION, INCLUDING THE CORRECT USE OF 1
BRACING.
ING VP Buildings, Inc.
Z A14D 3200 Players Club Circle Memphis TN 38125
FOR
REV DATE DESCRIPTION
Y
10/17/2001
NTS
12:49:45
W,4
gyp. l�\sz&9
PE10
9 TATE QF
•%
O�� �•• p� ANP
Ss�ONAL
SECONDARY ELEVATION AT A
Systems Builders, Inc.
Capitol Construction
Indianapolis, Indiana
OH0111248-010EIDWGS
FILENAME
OH0111248-OlOE1DWGS.vpc
4101 1
JOB R
OH0111243-01
DATE
10/2/2001
P BUILDINGS DRAWN/CHECK
VAROO-PRUDEN GJS GSS