HomeMy WebLinkAbout45Covering Schedule
Id Qty Start Panel Last Panel
#445 6 V26022261KAG
#446 13 V18076261KAG
#447 9 V09016261KAG
Direction
Left to Right
Left to Right
Left to Right
Insulation Schedule (Install in same direction as Covering)
Id
Qty Start Run
Last Run
BLK1
1
IB027006004OPS
Regal White
BLK2
2
IB027007204OPS
IB027007204OPS
BLK3
7
IB0200072040PS
IB020007204OPS
BLK4
5
IB010007204OPS
IB010007204OPS
VP Ref:
Ash Gray
Shape Name = Capitol,
Wall = 1
a
a,
O
P4
0
E a
\ N
H
M
A
(6)#44
T12
T
rn
E
Start Ditn•
4"
18'-4"
57'-4"
Trim Schedule
Id Kit Qty Parts
T1 3'-4" DF05,JT05
T2 3'-4" DF05,HTS05
T3 3'-4" TDFHO5
T4 9'-6" MWT10
T5 30'-2" BAI,TRMX01
T6 7'-6 1/4" MWT10
T7 37'-11" BAI,TRMX01
T8 16'-11" BAI,TRMX01
T9 26'-2 1/4" AFTI2,AFT16,CTE12,CTE16,GAC1053
T10 9'-2 1/4" AFT10,CTE10,GAC1053
T11 85'-0" RFR10,RKF20,TDF710
T12 1 PRFI,RFCIL
T13 1 BSI,GGCI,HCPOR
T14 1 MCCl
(13)#44
T11
Color
Details
Regal White
WC24B1
Regal White
WC24B2
Regal White
WC24B4
Ash Gray
WCX002
Ash Gray
WCX001
Ash Gray
WCX002
Ash Gray
WCX001
Ash Gray
WCX001
Ash Gray
WC18B2
Ash Gray
WC18B2
Egyptian White
RCX002
Egyptian White
REMAINS THE PROPERTY OF VP BUILDINGS.
Egyptian White
RC38A1,RC52A6
Egyptian White
RC38A1
R
(9)#447
Irl A
sb'-0
COVERING ELEVATION AT 1
was
��. ,,......,•.
V4�G-Irt��Fo
(STATE OF
sSIPNM_. �
VP Ref: Shape
Name = Capitol, Wall = 1
(i
1. WALL SHEETS ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM,
THE VP ENGINEER'S SEAL APPLIES
Building Code: 97UBC
THIS DRAWING, INCLUDING THE INFORMATION HER
ON,
REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED.
ONLY TO THE WORK PRODUCT OF
Live Load: (Not Reducible) 20.00 psf
REMAINS THE PROPERTY OF VP BUILDINGS.
VP Buildings, Inc.
g �
2. SEE JOB DETAILS FOR SHEETING AND TRIM FASTENER SPECIFICATION.
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED
Coll. Load•Gravit 5.00, Uplift 0.00
y psf
IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING
DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND
3200 Players Club Circle Memphis TN 38125
COVERING ELEVATION AT
1
3. PRE -DRILLING 1/8 DIAMETER HOLES FOR WALL STRUCTURAL FASTENERS
BY VP.
Wind Speed: 71.00 mph
SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR
MAY BE REQUIRED AT 11 GAGE GIRTS, NESTED GIRTS, GIRT LAP
THE VP ENGINEER'S SEAL DOES
NOT APPLY TO THE PERFORMANCE
Wind Exposure: B
ANY OTHER PURPOSE WITHOUT PRIOR WRITTENBUILDER
APPROVAL OF VP BUILDINGS.
REv DATE BY DESCRIPTION
JOB#
LOCATIONS, AND/OR SECONDARY STRUCTURAL BEAMS
OR DESIGN OF ANY OTHER PRODUCT
Ground Snow: 20.00 , Roof Snow: 20.00 psf
Systems Builders, Inc.
OH0111248-01
OR COMPONENT FURNISHED BY VP
Snow Exposure Category: 3
THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY
CUSTOMER
Capitol Construction
L
DATE
EXCEPT TO ANY DESIGNOR PER-
Seismic: Zone 1
RESPONSIBLE FOR ACCURATE, GOOD QUALITY WORKMANSHI&
IN ERECTING THIS BUILDING IN CONFORMANCE WITH
THIS
LOCATION
AVARCO-P�RUDRN
10/17/2001
FORMANCE REQUIREMENTS
SPECIFIED
Building Use: Standard occupancies
g p
DRAWING, DETAILS REFERENCED IN THIS DRAWING
I
Indianapolis, Indiana
ILINGS
D—N/CHECK
By VP,
ALL APPLICABLE VP ERECTION GUIDES,
AND INDUSTRY STANDARDS PERTAINING TO PROPER
PROJECT
OH0111248-01EP2 Drawings
TGW/ TGW
ERECTION, INCLUDING THE CORRECT USE OF TEMP
RARY
BUILOERs PON
PAGE
BRACING.
NTS
VPC VERSION, 2.6
Ca
10/16/2001 17:59:20
FILENAME OH0111248-01EP2 Drawings.vpc