HomeMy WebLinkAbout48Covering
Schedule
Parts
Id
Qty
Start Panel Last Panel
Direction
#799
12
V10003261KAG V18096261KAG
Left to Right
#800
23
V26020261KAG
Left to Right
#801
6
V21006261KAG
Left to Right
Insulation Schedule (Install in same direction as Covering)
Id Qty Start Run Last Run
BLK1 1 IB012006004OPS
BLK2 5 IB014007204OPS IB020007204OPS
BLK3 15 IB028007204OPS IB028007204OPS
VP Ref: Shape Name = Capitol, Wall = 4
c
I
rn
Start Dim.
4"
36'-4",51'-4",111'-4"
42'-4",102'-4"
Trim Schedule
Id
Kit Qty
Parts
Tl
123'-0"
HSEPI,RFR10,RKF20
T2
64'-1"
BAl,TRMX01
T3
3'-4"
DF05,JT05
T4
3'-4"
DF05,HTS05
T5
3'-4"
TDFH05
T6
5'-1 1/4"
DF10,JT07
T7
10'-8"
DF12,HTS12
T8
7'-0 1/4"
MWT10
Color
Egyptian White
Ash Gray
Regal White
Regal White
Regal White
Regal White
Regal White
Ash Gray
Details
RC34H4,RC35L2,WC13B3
WCX001
WC24B1
WC24B2
WC24B4
WC24B1
WC24B2
WCX002
1
6
(12)#799 (2)#800 (3)#801-- (17) #800 # uQm
123'-0"
COVERING ELEVATION AT R
1. WALL SHEETS, ARE AN INTEGRAL PART OF THE STRUCTURAL SYSTEM,
REMOVAL OR ALTERATION WITHOUT PRIOR AUTHORIZATION IS PROHIBITED.
2- SEE JOB DETAILS FOR SHEETING AND TRIM FASTENER SPECIFICATION.
3. PRE -DRILLING 1/8 DIAMETER HOLES FOR WALL STRUCTURAL FASTENERS
MAY BE REQUIRED AT 11 GAGE GIRTS, NESTED GIRTS, GIRT LAP
LOCATIONS, AND/OR SECONDARY STRUCTURAL BEAMS
THE VP ENGINEER'S SEAL APPLIES
ONLY TO THE WORK PRODUCT OF
VP AND DESIGN AND PERFORMANCE
REQUIREMENTS SPECIFIED BY Vp.
THE VP ENGINEER'S SEAL DOES
NOT APPLY TO THE PERFORMANCE
OR DESIGN OF ANY OTHER PRODUCT
OR COMPONENT FURNISHED BY VP
EXCEPT TO ANY DESIGN OR PER-
FORMAANCE REQUIREMENTS
SPECIFIED BY VP.
VP Ref: Shape Name
Building Code: 97UBC
Live Load: (Not Reducible) 20.00 psf
Coll. Load:Gravity 5.00, Uplift 0.00 psf
eed
Wind S : 71.00 m
p ph
Wind Exposure: B
Ground Snow: 20.00 Roof Snow: 20.00 psf
Snow Exposure Category: 3
Seismic: Zone 1
Building Use:Standard occupancies
= Capitol, Wall = 4
THISDRAWING ,INCLUDINGTHE INFORMATIONHERON,
REMAINS THE PROPERTY OF VP BUILDINGS.
IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING
DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND
SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR
ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN
APPROVAL OF VP BUILDINGS.
VP Buildings, Inc.
3200 Players Club Circle Memphis TN 38125
REV DATE 13Y DESCRIPTION
THE GENERAL CONTRACTOR AND/OR ERECTOR ISS LELY
RESPONSIBLE FOR ACCURATE, GOOD QUALITY WO KMANSHI
IN ERECTING THIS BUILDING IN CONFORMANCE WITH I THIS
DRAWING, DETAILS REFERENCED IN THIS DRAWING,
ALL APPLICABLE VP ERECTION GUIDES,
AND INDUSTRY STANDARDS PERTAINING TO PROPER
ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY
BRACING.
NTS
10/16/2001 17:59:23
� j k.,. WA
� ,..•....,, ,yam
O � ASTER '
Fa
� N
i
�t
STATE OF
FssIONM-���
COVERING ELEVATION AT R
ILDER
Systems Builders, Inc.
STOMER
Capitol Construction
CATION
Indianapolis, Indiana
OJECT
OH0111248-01EP2 Drawings
FILENAME:
OH0111248-01EP2 Drawings.vpc
JOB #
OH0111248-01
DATE
10/17/2001
P BUILDINGS DRAWN/CHECK
VARCO-PRUDEN TCW/ TGW
VPC VERSION: 2.6 PAGE C5