Loading...
HomeMy WebLinkAbouttrussRe: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Timberland Home Center-Brazil, IN. Pages or sheets covered by this seal: I35120833 thru I35120843 My license renewal date for the state of Indiana is July 31, 2020. 1500312 Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. IMPORTANT NOTE: MERIDIAN D 16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. October 30,2018 Liu, Xuegang Job 1500312 Truss A Truss Type MOD. QUEEN Qty 3 Ply 1 MERIDIAN D Job Reference (optional) I35120833 8.220 s Oct 6 2018 MiTek Industries, Inc. Mon Oct 29 16:29:36 2018 Page 1 Timberland Home Center, Brazil, IN - 47834, ID:zrnD?hJQ8196XrjEltqqBiyi1AM-Y3JJ1jJVjFHfOh_6OpXXEFwniT04ZOA9gtLPRyyOVIz Scale = 1:68.9 1 2 3 4 5 6 7 8 9 10 11 17 16 15 14 13 12 18 19 6x6 3x6 3x6 5x6 3x6 3x4 2x4 3x4 3x4 3x8 3x4 4x6 3x6 2x8 3x6 10-1-1 10-1-1 20-0-0 9-10-15 29-10-15 9-10-15 38-0-0 8-1-1 -0-9-12 0-9-12 6-9-6 6-9-6 13-4-11 6-7-5 20-0-0 6-7-5 26-7-5 6-7-5 33-2-10 6-7-5 38-0-0 4-9-6 38-9-12 0-9-12 0-6-610-6-61-6-66.00 12 Plate Offsets (X,Y)-- [2:0-1-1,0-0-8], [2:0-6-12,0-1-1], [2:Edge,0-3-2] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.77 0.93 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.26 -0.75 0.15 (loc) 2-17 2-17 12 l/defl >999 >607 n/a L/d 240 180 n/a PLATES MT20 Weight: 162 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-17,9-13,9-12,10-12: 2x4 SPF Stud/No.3 WEDGE Left: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 2-17. WEBS 1 Row at midpt 5-15, 7-15, 9-12 REACTIONS.(lb/size) 2=1566/0-3-8, 12=1566/0-3-8 Max Horz 2=-3(LC 5) Max Uplift 2=-231(LC 5), 12=-230(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2702/389, 3-5=-2448/375, 5-6=-1675/344, 6-7=-1676/345, 7-9=-2085/333 BOT CHORD 2-17=-253/2321, 15-17=-125/1897, 13-15=-109/1743, 12-13=-171/1708 WEBS 3-17=-307/181, 5-17=-7/544, 5-15=-782/206, 6-15=-163/1053, 7-15=-579/183, 7-13=0/253, 9-12=-2041/250 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=231, 12=230. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 30,2018 Job 1500312 Truss A1 Truss Type MOD. QUEEN Qty 2 Ply 1 MERIDIAN D Job Reference (optional) I35120834 8.220 s Oct 6 2018 MiTek Industries, Inc. Mon Oct 29 16:29:37 2018 Page 1 Timberland Home Center, Brazil, IN - 47834, ID:R2LbC1K2vKHz9?IQJaM3jvyi1AL-0FthF3J7UZPW0rZIyX2mnSTzVsLgIrPIvX4z_PyOVIy Scale = 1:68.5 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 6x6 3x6 3x6 5x6 3x6 3x4 2x4 3x4 3x4 3x8 3x4 4x6 3x6 2x8 3x6 10-1-1 10-1-1 20-0-0 9-10-15 29-10-15 9-10-15 38-0-0 8-1-1 6-9-6 6-9-6 13-4-11 6-7-5 20-0-0 6-7-5 26-7-5 6-7-5 33-2-10 6-7-5 38-0-0 4-9-6 38-9-12 0-9-12 0-6-610-6-61-6-66.00 12 Plate Offsets (X,Y)-- [1:0-1-1,0-0-8], [1:0-6-12,0-1-1], [1:Edge,0-3-2] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.77 0.97 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.28 -0.78 0.15 (loc) 1-16 1-16 11 l/defl >999 >583 n/a L/d 240 180 n/a PLATES MT20 Weight: 161 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-16,8-12,8-11,9-11: 2x4 SPF Stud/No.3 WEDGE Left: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 1-16. WEBS 1 Row at midpt 4-14, 6-14, 8-11 REACTIONS.(lb/size) 1=1508/0-3-8, 11=1567/0-3-8 Max Horz 1=-13(LC 5) Max Uplift 1=-190(LC 5), 11=-231(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2709/395, 2-4=-2453/379, 4-5=-1676/345, 5-6=-1678/346, 6-8=-2086/334 BOT CHORD 1-16=-261/2328, 14-16=-126/1900, 12-14=-110/1744, 11-12=-171/1709 WEBS 2-16=-312/188, 4-16=-10/545, 4-14=-784/206, 5-14=-164/1054, 6-14=-572/183, 6-12=0/253, 8-11=-2042/251 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=190, 11=231. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 30,2018 Job 1500312 Truss AGE Truss Type GABLE Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I35120835 8.220 s Oct 6 2018 MiTek Industries, Inc. Mon Oct 29 16:29:38 2018 Page 1 Timberland Home Center, Brazil, IN - 47834, ID:vEv_QNKggePqm9tctHtIG7yi1AK-URR3SPKlFtXNe?8UVEZ?Jg0HyGvb1PzS8BqWWryOVIx Scale = 1:68.5 Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 2728 29 30 31 32 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 333x8 3x6 5x6 3x6 3x6 5x6 38-0-0 38-0-0 20-0-0 20-0-0 38-0-0 18-0-0 38-9-12 0-9-12 0-6-610-6-61-6-66.00 12 Plate Offsets (X,Y)-- [1:0-0-8,0-1-1], [1:0-1-1,0-6-12], [1:0-3-8,Edge], [54:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.14 0.09 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 32 32 33 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 264 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 *Except* 16-48,15-49,14-50,13-51,12-52,17-47,18-46,19-45,20-44: 2x4 SPF No.2 WEDGE Left: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 16-48, 15-49, 14-50, 13-51, 17-47, 18-46, 19-45 REACTIONS.All bearings 38-0-0. (lb) - Max Horz 1=-13(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 46, 45, 44, 42, 41, 40, 39, 38, 37, 36, 35 except 34=-135(LC 5) Max Grav All reactions 250 lb or less at joint(s) 1, 33, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 47, 46, 45, 44, 42, 41, 40, 39, 38, 37, 36, 35, 34 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 13-14=-30/261, 14-15=-31/290, 15-16=-33/302, 16-17=-31/302, 17-18=-29/290, 18-19=-28/261 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 46, 45, 44, 42, 41, 40, 39, 38, 37, 36, 35 except (jt=lb) 34=135. 11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 30,2018 Job 1500312 Truss AT Truss Type SPECIAL Qty 6 Ply 1 MERIDIAN D Job Reference (optional) I35120836 8.220 s Oct 6 2018 MiTek Industries, Inc. Mon Oct 29 16:29:39 2018 Page 1 Timberland Home Center, Brazil, IN - 47834, ID:rd1kr3MwCFfY0S0?_ivmLYyi1AI-ye?RflLN?AfEF8jh3y5EstYGKg5RmigbMrZ32HyOVIw Scale = 1:69.6 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 19 20 8x8 5x9 3x6 2x8 2x4 4x9 2x8 6x12 2x4 2x4 3x6 2x4 5x9 3x4 3x4 4x6 3x6 2x8 2-3-8 2-3-8 8-2-0 5-10-8 12-10-8 4-8-8 20-0-0 7-1-8 29-5-3 9-5-3 38-0-0 8-6-13 2-3-8 2-3-8 8-2-0 5-10-8 12-10-8 4-8-8 20-0-0 7-1-8 25-10-13 5-10-13 31-9-11 5-10-13 38-0-0 6-2-5 38-11-4 0-11-4 0-6-610-6-61-6-61-0-06.00 12 Plate Offsets (X,Y)-- [2:0-8-4,0-0-0], [3:0-3-8,Edge], [16:0-6-0,0-2-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.94 0.76 0.72 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.29 -0.74 0.38 (loc) 2-17 2-17 11 l/defl >999 >612 n/a L/d 240 180 n/a PLATES MT20 Weight: 194 lb FT = 0% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-5: 2x4 SPF-S 1650F 1.6E, 1-3: 2x8 SP 2250F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 1-18,2-18: 2x4 SPF Stud/No.3, 2-16: 2x4 SPF-S 1650F 1.6E WEBS 2x4 SPF Stud/No.3 *Except* 5-16,5-14,6-14,6-12: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-9-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-14, 8-11 REACTIONS.(lb/size) 1=1509/0-3-8, 11=1573/0-3-8 Max Horz 1=-21(LC 5) Max Uplift 1=-189(LC 5), 11=-237(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-565/111, 2-3=-3350/421, 3-4=-2630/405, 4-5=-2639/537, 5-6=-1660/351, 6-8=-2083/357, 8-9=-283/135, 9-11=-342/163 BOT CHORD 2-17=-280/3097, 16-17=-276/3105, 12-14=-91/1704, 11-12=-158/1792 WEBS 4-16=-439/200, 3-17=0/279, 3-16=-977/148, 14-16=0/1365, 5-16=-281/1500, 5-14=-28/456, 6-14=-567/172, 6-12=0/296, 8-11=-1991/200 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=189, 11=237. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 30,2018 Job 1500312 Truss V1 Truss Type VALLEY Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I35120837 8.220 s Oct 6 2018 MiTek Industries, Inc. Mon Oct 29 16:29:40 2018 Page 1 Timberland Home Center, Brazil, IN - 47834, ID:rd1kr3MwCFfY0S0?_ivmLYyi1AI-QqZqt5M?mUn5tIItdfcTP55fN4caVK6lbVJdakyOVIv Scale = 1:7.5 1 2 3 2x4 3x6 2x4 2-6-11 2-6-11 1-3-6 1-3-6 2-6-11 1-3-6 0-11-89.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.02 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-6-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=67/2-6-11, 3=67/2-6-11 Max Uplift 1=-8(LC 3), 3=-8(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 30,2018 Job 1500312 Truss V2 Truss Type VALLEY Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I35120838 8.220 s Oct 6 2018 MiTek Industries, Inc. Mon Oct 29 16:29:40 2018 Page 1 Timberland Home Center, Brazil, IN - 47834, ID:o?8UGlOAjtvGFmAN67xEQzyi1AG-QqZqt5M?mUn5tIItdfcTP55dV4b1VKllbVJdakyOVIv Scale = 1:14.2 1 2 3 4 2x4 4x6 2x4 2x4 5-2-11 5-2-11 2-7-6 2-7-6 5-2-11 2-7-6 1-11-89.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.14 0.09 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=96/5-2-11, 3=96/5-2-11, 4=156/5-2-11 Max Uplift 1=-25(LC 5), 3=-25(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 30,2018 Job 1500312 Truss V3 Truss Type VALLEY Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I35120839 8.220 s Oct 6 2018 MiTek Industries, Inc. Mon Oct 29 16:29:41 2018 Page 1 Timberland Home Center, Brazil, IN - 47834, ID:GCitT5OpUA17twlagrTTzAyi1AF-u07C4RMdXnvyVSs3BM7ixIelgUwcEnjuq92A7AyOVIu Scale = 1:19.6 1 2 3 4 5 6 2x4 4x6 2x4 2x4 7-10-11 7-10-11 3-11-6 3-11-6 7-10-11 3-11-6 2-11-89.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.37 0.14 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 22 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=156/7-10-11, 3=156/7-10-11, 4=250/7-10-11 Max Uplift 1=-36(LC 5), 3=-36(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 30,2018 Job 1500312 Truss V4 Truss Type VALLEY Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I35120840 8.220 s Oct 6 2018 MiTek Industries, Inc. Mon Oct 29 16:29:41 2018 Page 1 Timberland Home Center, Brazil, IN - 47834, ID:kOGFgRPRFU9zU4KmDY_iWOyi1AE-u07C4RMdXnvyVSs3BM7ixIenKUviEmAuq92A7AyOVIu Scale = 1:25.1 1 2 3 4 5 6 2x8 4x6 2x8 2x4 10-6-11 10-6-11 5-3-6 5-3-6 10-6-11 5-3-6 3-11-89.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.20 0.19 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 30 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=200/10-6-11, 3=200/10-6-11, 4=374/10-6-11 Max Uplift 1=-35(LC 5), 3=-35(LC 5), 4=-1(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 30,2018 Job 1500312 Truss V5 Truss Type VALLEY Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I35120841 8.220 s Oct 6 2018 MiTek Industries, Inc. Mon Oct 29 16:29:42 2018 Page 1 Timberland Home Center, Brazil, IN - 47834, ID:CaqdumQ30oHq6DvynFVx2byi1AD-MDgaImNFI51p6cRGk4exUWAyItHTzDO12pojfcyOVIt Scale = 1:30.7 1 2 3 4 5 8 7 6 9 10 3x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 13-2-11 13-2-11 6-7-6 6-7-6 13-2-11 6-7-6 4-11-89.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.19 0.10 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 41 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-2-11. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=252(LC 1), 8=306(LC 2), 6=306(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 30,2018 Job 1500312 Truss V6 Truss Type VALLEY Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I35120842 8.220 s Oct 6 2018 MiTek Industries, Inc. Mon Oct 29 16:29:42 2018 Page 1 Timberland Home Center, Brazil, IN - 47834, ID:gnO?56Rhn5PhkNU9Lz0Abpyi1AC-MDgaImNFI51p6cRGk4exUWAydtHWzDy12pojfcyOVIt Scale = 1:36.9 1 2 3 4 5 8 7 6 9 10 3x4 4x6 3x4 5x6 2x4 2x4 2x4 2x4 15-10-11 15-10-11 7-11-6 7-11-6 15-10-11 7-11-6 5-11-89.00 12 Plate Offsets (X,Y)-- [7:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.16 0.09 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 51 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-10-11. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 8 except 6=-101(LC 5) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=365(LC 2), 6=364(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-276/146, 4-6=-276/145 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb) 6=101. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 30,2018 Job 1500312 Truss VG7 Truss Type GABLE Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I35120843 8.220 s Oct 6 2018 MiTek Industries, Inc. Mon Oct 29 16:29:43 2018 Page 1 Timberland Home Center, Brazil, IN - 47834, ID:8zyNJSRJYPYYLX3LvgXP70yi1AB-rPEyV6Ou3P9gkm0SIn9A0jj8eHdFifpBHTXHB3yOVIs Scale = 1:38.5 Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 11 21 20 19 18 17 16 15 14 13 12 22 23 3x4 4x6 3x4 3x6 17-0-3 17-0-3 8-6-2 8-6-2 17-0-3 8-6-2 6-4-99.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.08 0.06 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 79 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 17-0-3. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 18, 19, 20, 21, 15, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 1, 11, 17, 18, 19, 20, 21, 15, 14, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 19, 20, 21, 15, 14, 13, 12. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. October 30,2018 edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 8 7 6 54321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015WEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 8 7 6 54321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System General Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.