HomeMy WebLinkAbout20180713 18250 Carmel Detox ComcheckCOMcheck Software Version 4.1.0.0 Interior Lighting Compliance Certificate Project Title: 90.1 (2007) Standard Project Type: New Construction Construction Site: 13590 N. MERIDIAN ST. CARMEL, IN 46302 Owner/Agent: AVON CARMEL, LLC 106 FINNELL DR. UNIT 1 WEYMOUTH, MA 02188 Designer/Contractor: Keith A. Pharis, PE LEED AP FORZA ARCHITECTURE 654 S. SHELBY ST SUITE 301 LOUISVILLE, KY 40202 502-471-7963 ka.pharis@pharisengineering.com Project Information Energy Code: LANDMARK RECOVERY OF CARMEL Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Detox Facility (Office) 15600 1.00 15600 Total Allowed Watts = 15600 Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures 1-Detox Facility (Office) LED 1: D1: LED Other Fixture Unit 16W: 1 96 15 1440 LED 2: D2: LED Other Fixture Unit 36W: 1 27 35 945 LED 3: D3: LED Other Fixture Unit 25W: 1 8 25 200 LED 4: DW: LED Other Fixture Unit 28W: 1 8 30 240 LED 5: T1: LED Panel 44W: 1 35 47 1645 LED 6: T2: LED Panel 36W: 1 22 36 792 LED 7: T3: LED Panel 60W: 1 3 64 192 Name - Title Signature Date Project Title: Data filename: LANDMARK RECOVERY OF CARMEL C:\Users\Keith\OneDrive\Engineering\2018\18250 Carmel IN Forza\Calcs\CARMELDETOXashrae.cck Report date: 07/13/18 Page 2 of 8 Keith A. Pharis, PE LEED AP Electrical Engineer 07/13/2018 COMcheck Software Version 4.1.0.0 Exterior Lighting Compliance Certificate Project Title: 90.1 (2007) Standard Project Type: New Construction Construction Site: 13590 N. MERIDIAN ST. CARMEL, IN 46302 Owner/Agent: AVON CARMEL, LLC 106 FINNELL DR. UNIT 1 WEYMOUTH, MA 02188 Designer/Contractor: Keith A. Pharis, PE LEED AP FORZA ARCHITECTURE 654 S. SHELBY ST SUITE 301 LOUISVILLE, KY 40202 502-471-7963 ka.pharis@pharisengineering.com Project Information Energy Code: LANDMARK RECOVERY OF CARMEL Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) Main entry/exit 6 ft of door 30 Yes 180 Other entry/exit 3 ft of door 20 Yes 60 Other entry/exit 3 ft of door 20 Yes 60 Other entry/exit 3 ft of door 20 Yes 60 Other entry/exit 6 ft of door 20 Yes 120 Other entry/exit 6 ft of door 20 Yes 120 Other entry/exit 6 ft of door 20 Yes 120 Illuminated length of wall or surface 150 ft 5 No 750 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 720 1470 74 (a) Wattage tradeoffs are only allowed between tradable areas/surfaces. (b) A supplemental allowance equal to 74 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Illuminated length of facade wall or surface (150 ft): Non-tradable Wattage LED 2: OL2: Ext LED Flood: LED Other Fixture Unit 46W: 1 6 45 270 Total Tradable Proposed Watts = 165 Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Exterior Lighting PASSES: Design 79% better than code Project Title: Data filename: LANDMARK RECOVERY OF CARMEL C:\Users\Keith\OneDrive\Engineering\2018\18250 Carmel IN Forza\Calcs\CARMELDETOXashrae.cck Report date: 07/13/18 Page 4 of 8 Keith A. Pharis, PE LEED AP Electrical Engineer 07/13/2018 Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.0.0 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 90.1 (2007) Standard Section # & Req.ID Plan Review Complies? Comments/Assumptions 4.2.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable 8.4.1.1, 8.4.1.2 [PR6]2 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: LANDMARK RECOVERY OF CARMEL C:\Users\Keith\OneDrive\Engineering\2018\18250 Carmel IN Forza\Calcs\CARMELDETOXashrae.cck Report date: 07/13/18 Page 5 of 8 X X Requirement is met. Requirement is met. Section # & Req.ID Rough-In Electrical Inspection Complies? Comments/Assumptions 9.4.1.1 [EL1]2 Automatic controls to shut off all building lighting installed in buildings >5,000 ft2. Complies Does Not Not Observable Not Applicable 9.4.1.2 [EL2]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable 9.4.1.3 [EL3]2 Automatic lighting controls for exterior lighting installed. Complies Does Not Not Observable Not Applicable 9.4.1.4 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable 9.4.2 [EL5]3 Ballasted one and three lamp fixtures with >30 W/lamp have two lamp tandem wired ballasts when >=2 fixtures in same space on same control. Complies Does Not Not Observable Not Applicable 9.4.3 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable 9.4.4 Section # & Req.ID Final Inspection Complies? Comments/Assumptions 8.7.1 [FI16]3 Furnished as-built drawings for electric power systems within 30 days of system acceptance. Complies Does Not Not Observable Not Applicable 8.7.2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable 9.2.2.3 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. 9.4.5 [FI19]1 Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Exterior Lighting fixture schedule for values. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: LANDMARK RECOVERY OF CARMEL C:\Users\Keith\OneDrive\Engineering\2018\18250 Carmel IN Forza\Calcs\CARMELDETOXashrae.cck Report date: 07/13/18 Page 7 of 8 Will be provided at project completion X X Project Title: Data filename: LANDMARK RECOVERY OF CARMEL C:\Users\Keith\OneDrive\Engineering\2018\18250 Carmel IN Forza\Calcs\CARMELDETOXashrae.cck Report date: 07/13/18 Page 8 of 8 X X Will be installed per plans and specs Will be installed per plans and specs Will be provided at project completion [EL7]1 Exterior grounds lighting over 100 W provides >60 lm/W unless on motion sensor or fixture is exempt from scope of code or from external LPD. Complies Does Not Not Observable Not Applicable 9.6.2 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: LANDMARK RECOVERY OF CARMEL C:\Users\Keith\OneDrive\Engineering\2018\18250 Carmel IN Forza\Calcs\CARMELDETOXashrae.cck Report date: 07/13/18 Page 6 of 8 X X X X X X X X Requirement is met. Will be installed per plans and specs Will be installed per plans and specs Will be installed per plans and specs Requirement is met. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Main entry (6 ft of door width): Tradable Wattage LED 1: OL1: LED Wall Sconce: LED Other Fixture Unit 13W: 1 2 15 30 Other door (not main entry) (3 ft of door width): Tradable Wattage LED 2: OL1: LED Wall Sconce: LED Other Fixture Unit 13W: 1 1 15 15 LED 1: OL1: Ext LED Wall Sconce: LED Other Fixture Unit 13W: 1 1 15 15 LED 1: OL1: Ext LED Wall Sconce: LED Other Fixture Unit 13W: 1 1 15 15 Other door (not main entry) (6 ft of door width): Tradable Wattage LED 1: OL1: Ext LED Wall Sconce: LED Other Fixture Unit 13W: 1 2 15 30 LED 1: OL1: Ext LED Wall Sconce: LED Other Fixture Unit 13W: 1 2 15 30 LED 1: OL1: Ext LED Wall Sconce: LED Other Fixture Unit 13W: 1 2 15 30 Project Title: Data filename: LANDMARK RECOVERY OF CARMEL C:\Users\Keith\OneDrive\Engineering\2018\18250 Carmel IN Forza\Calcs\CARMELDETOXashrae.cck Report date: 07/13/18 Page 3 of 8 LED 8: T4: LED Panel 44W: 1 18 45 810 LED 9: T5: LED Panel 33W: 1 51 28 1428 LED 10: T6: LED Panel 54W: 1 8 54 432 LED 11: T7: LED Panel 33W: 1 23 28 644 LED 12: LED Linear 33W: 1 4 33 132 Total Proposed Watts = 8900 Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Interior Lighting PASSES: Design 43% better than code Project Title: Data filename: LANDMARK RECOVERY OF CARMEL C:\Users\Keith\OneDrive\Engineering\2018\18250 Carmel IN Forza\Calcs\CARMELDETOXashrae.cck Report date: 07/13/18 Page 1 of 8