ELECTRICAL PLAN SCALE = 1/8" = 1'-0" 1 )L 1-..d t 1 1--d1 11 N NOT TO SCALE U it AREA OF WORK I ELECTRICAL LEGEND 6 110 VOLT DUPLEX WALL RECEPTACLE 6 D.E.D. 110 VOLT DUPLEX WALL RECEPTACLE ON DEDICATED CIRCUIT 6 D.F.I. DUPLEX WALL RECEP. W/ 110 VOLT ON GROUND FAULT INTERRUPTER Q DATA WALL RECEPTACLE . TELEPHONE 7 TELEPHONE/DATA WALL RECEPTACLE JO JUNCTION BOX I � ELECTRICAL PANEL AFF ABOVE FINISH FLOOR O ELECTRICAL - FLOOR RECEPTACLE t DATA - FLOOR RECEPTACLE KEYED ELECTRICAL NOTES © VERIFY ALL ELECTRICAL NEEDS AND ELECTRICAL PANEL. LOCATION FOR SERVER ROOV WITH TEN.=\T OELECTRICAL IN THE CEILING TO ACCOMMODATE CEILING HUNG PROJECTOR OELECTRICAL IN CEILING TO ACCOMMODATE RECESSED PROJECTOR SCREEN OSECURITY CAMERA TO BE INSTALLED IN THIS AREA WITH (3)MONTTORS THROUGFIOUT THE SPACE. EXACT LOCATION TO BE VERIF:_�_ WITH TENANT. SEE KEYED NOTE 5 FOR DETAIL. VERIFY ALL ELECTRICAL NEEDS FOR SECURITY SYSTEM WITH TENA\ . OTHIS ROOM TO HAVE SECURITY MONITOR. COORDINATE WITH TENANT FOR EXACT LOCATION AND HEIGHT OF THE MONITOR. GENERAL ELECTRICAL PLAN NOTES A THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR. MATERIAL, EQUIPMENT, AND CONTRACTORS SERVICES NECESSARY TO COMPLETE INSTALLATION OF SYSTEMS REQUIRED IN FULL CONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE FINISHED JOB SHALL. BE FUNCTIONAL AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR A COMPLETE SYSTEM. B ALL MATERIAL AND WORKMANSHIP SHALL MEET ALL APPLICABLE STATE AND LOCAL CODES, ORDINANCES, UTILITY COMPANY REGULATIONS AND NATIONALLY ACCEPTED CODES AND STANDARDS. THE ELECTRICAL CONTRACTOR WILL BEAR ALL COSTS ARISING IN CORRECTING ANY NON-COMPLIANCE WITH THE REQUIRMENTS OF APPLICABLE CODES. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/DESIGNER OF ANY DISCREPANCIES BETWEEN THE CONTRACT DOCUMENTS AND APPLICABLE CODES PRIOI• TO CONSTRUCTION, D ELECTRICAL CONTRACTOR TO COORDINATE SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTS OF TENANT'S AS SPECIFICALLY INDICATED ON DRAWINGS. VERIFY ACTUAL REQUIREMENTS WITH ARCHITECT/DESIGNER PRIOR TO INSTALLATION. E ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AT TELEPHONE/DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE/DATA SYSTEMS (MATERIAL AND LABOR) ARE PROVIDED BY THE TENANT UNLESS NOTED OTHERWISE. F ELECTRIC.AI. CONTRACTOR SHALL COORDINATE ANY ELECTRICAL OR LICA ITIN('; REQUIREMEN'T'S OF MILLWORK WITH ARCHITECTURAL WOODWORK CONTRACTOR AS NECESSARY. G .ALI, WALL. MOUNTED OUTLETS ARE TO BE MOUNTED 15" A.F.F. TO CENTERLINE OF OUTLET, UNLESS NOTED OTHERWISE. Ff SWITCH PLATES, MONUMENTS. AND ELECTRICAL. COVER PLATES SHALL BE BCILDING STANDARD, UNLESS OTHERWISE NOTE'). I ALL DIMENSIONS SHOWN ARE TO CENTERLINE OF OUTLETS OR GfM;'PS OF 377LETS, UNLESS NOTED OTi J DO NOT LOCATE BOXES BACK T O BACK WITHIN PARTITIONS. STAGGER AS REQUIKED TO ';:Nl�lllE SG�.`.D 7'RANSMh�,u'- K ADJACENT OUTLETS SHALL, BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE GANGED. TI -Y SHALL BE INSTALLED WITI I 't MINIMUM DISTANCE BETWEEN UNITS. L PROVIDE EMERGENCY STROBES AND HORNS AS REQUIRED BY STATE AND LOCAL BUILDING CODF.� N1 ANY ABANDONED ELECTRICAL OR COMMUNICATIONS BOXES REMAINI.NG IN WALLS ARE T(% HAVE BLANK COVER PLATE - IN STALLED TO NI.ATCI I EXIST i',! N ELECTRICAL CONTRACTOR TO VERIFY WORKING CONDITION OF ALL SWITCHES, LIGHT Fff--,RES, BALLASTS, EXIT, AND EMERGENCY LIGHTS AND OUTLETS: REPLACE IF NECESSARY. 0 DO NOT SCALE DRAWINGS. ALL DIMENSIONS GIVEN ARE TO BE ADHERED TO. UNLESS FIE1_ CONDITIONS DEEM OTHERW:, i ANY CONFLICTS TI IAT MAY EX'ST W/ NEW CONSTRUCTION MUST BE REVIEWED BY ARCH:-'. -T PRIOR TO CONSTRUCTION OF WORK. DO NOT CIRCUMVENT DIMENSIONS BY ATTACHING RECEPTACLES TO 'NEAREST ST1 _ P THESE ELECTRICAL DRAWINGS REFLECT LOCATIONS ONLY. CONSL7-T WITH ELECTRICAL ENGINEER FOR FURTHER TECHNIC:'.) LNFORALATION Q ELECTRICAL/I)ATA Ot*T'.ET !.`)CATIONS TO BE COORDINATED WITH TENANT PRIOR TO PC i'. -IN. ALL LOCATIO) IS TO F,'_ t''RIFIED WITH FL F'\ITCRE I':.',_iE%1E'; 8/14/02 100% CONSTRUCTION SET HILLENBRAND MITSCH DESIGN 10401 NORTH MERIDIAN STREET SUITE 100 INDIANAPOLIS, INDIANA 46290 (VOICE) 317-573-2222 (FAX) 317-573-2230 LAKESIDE CDR PORATE CENTRE 0 vo TURLEY MARTIN NqW ARCHITECTS PLANNERS I 13 S. RAINGELINE RD. SUITE 20, CARMEL. IN 460:3 R� R• y% A,,�i GASTEp� ��.. o �o j No. 4184 STATE OF ` 4K �C i DATP: 30 JUL 02 SCALP: 1/8" = 1'-C' DRAWN: JHP RPS"?SION All tdca- designs, and plans indicated w represecced by these drawings are ownec by. anc to property of Hillenbrand Mitsch Design. Contractors sha'l verik an'. be responsible for all dimensions or th• job site All rights reserved, except for uses expressly permitted in Writing. D RA Ai' I N Cl N A'X 11: ELECTRICAL PLAt4 PROJEC -F: SI IPI; 0�,8�,1 F.