Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Plans
1 COMMUNITY MEDICAL PAVILION 11911 NORTH MERIDIAN STREET CARMEL, INDIANA 46032 1 13 MAY uAN&� DAVID POWERS ARCHITECT, P.C. I CARSON DESIGN I SET NUMBER 5816 CARROLLTON AVENUE ASSOCIATES g t r INDIANAPOLIS IN 46220 TEL 317.843.5979 AMf Ll FAX7 I .843.5975 3 TEL 317.627.5820;5 FAX 317.255.0468 EMAIL Carson@carsondesign.com� � i ii "fs4 za E MAILersarch Ian@aol.com' 4 P P 11590 N. MERIDIAN d (t 3 x { p r SUITE 104 CARMEL INDIANA 46032 INDIANA HEART ASSOCIATES COMMUNITY MEDICAL PAVILION 77711 2'-0" 2'-0" �,, �0 WALL TYPE NOTES ATTACH METAL STUDS TO UNDERSIDE ATTACH METAL STUDS TO UNDERSIDE SUSPENDED ACOUSTICAL CEILING TILE_ SUSPENDED ACOUSTICAL CEILING TILE. OF DECK. OF STRUCTURE. PROVIDE DEEP LEG TRACK WHERE STUDS ATTACH TO STRUCTURE SOUND BATT INSULATION 2'-0" EA. SIDE OF UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLANS ABOVE Cx_ STUD ABOVE CEILING. ALL WALLS TO BE WALL TYPE #2. CHICAGO METALLIC ELIMINATOR CHICAGO METALLIC ELIMINATOR TRACK. BUILT IN TRIM EDGE W/ 3/4' TRACK. BUILT IN TRIM EDGE W/ 3/466(" NOTE; REFER TO ROOM FINISH SCHEDULE FOR WALL BASE TYPES.AT RATED WALL ONLY-PROVIDE PROTECTIVE TAPE. FLAT TAPE ONLY_ PROTECTIVE TAPE. FLAT TAPE ONLY. CARSON DESIGN NOTE; PROVIDE CONTROL JOINTS IN ALL METAL STUD/ A 1/4" BEAD OF FIRE RATED CAULKING. SPACKLE AND SAND. SPACKLE AND SAND. 3-5/8" METAL STUDS AT 16' GYP BOARD WALLS AT 30'-0" MAXIMUM SPACING. O.C. WITH 5/8" GYPSUM BOARD &=<SUSPENDED ACOUSTICAL CEILING TILE. ASSOCIATES AT RATED WALLS STUFF CONTROL JOINT FULL WITH SUSPENDED ACOUSTICAL CEILING TILE. SUSPENDED ACOUSTICAL CEILING TILE. EACH SIDE. 3-5 8 METAL STUDS AT SOUND ATTENUATION FIRE BLANKET. CHICAGO METALLIC ELIMINATOR 16" O.C. WITH 5/8" GYPSUM BOARD TEL 317.8435979 REFER TO FLOOR PLANS FOR LOCATION OF EACH D:� TRACK. BUILT IN TRIM EDGE W/ 3/4" EACH SIDE. FAX 317.843.5975 INDIVIDUAL WALL TYPE. PROTECTIVE TAPE. FLAT TAPE ONLY. AT RATED WALL; FOLLOW MANUFACTURERS PREVIOUSLY TESTED SPACKLE AND SAND. 11590 N. MERIDIAN ASSEMBLY CONSTRUCTION TECHNIQUES AS NOTED. COORDINATE SUITE 104 WITH MANU FOR ADDITIONAL INFORMATION. ASSEMBLY NUMBER AS TESTED IS 'SWRI PROJECT NO. 01-2602-620'. CARMEL INDIANA 46032 FILL WALL SOLID WITH SAFB(2.5 PCF) FILL WALL SOLID WITH SOUND ATTENUATION FILL WALL SOLID WITH SOUND ATTENUATION TEL 512977.0520 INSULATION IN THICKNESS TO BATTS INSULATION IN THICKNESS TO BATTS INSULATION IN THICKNESS TO FILL WALL SOLID WITH SOUND ATTENUATI�PJ MATCH REQUIRED METAL STUD SIZE. MATCH REQUIRED METAL STUD SIZE. MATCH REQUIRED METAL STUD SIZE. BATTS INSULATION IN THICKNESS TO FAX 512977.0384 3-5/8" METAL STUDS AT 16" O.C. 3-5/8' METAL STUDS AT 16" O.C.C>< MATCH REQUIRED METAL STUD SIZE. 4201 W PARMER LANE WITH 5/8" TYPE X' GYPSUM BOARD EA SIDE. WITH 5/8" GYPSUM BOARD EA SIDE. 3 5/8" 25 GA METAL STUDS AT 16' O.C. SUFE 104 f WITH 5/8' GYP. BOARD EACH SIDE FLOOR LINE FLOOR LINE FLOOR LINE TO 6' ABOVE CEILING. FLOOR LINE AUSTIN TEXAS 78727 C>< L�j . ---" vrww.cwsorde0vxC0m WALL TYPE #5 NOT USED WALL TYPE #4 WALL TYPE NOT USED WALL TYPE #2 WALL TYPE #1 ONE HOUR RATED ASSEMBLY POWERS ATTACH GYP BD WITH 1 1 /4" TYPE "S" DRYWALL � NOTE; TYPICAL FOR ALL NEW WALLS ENCLOSING DAVID, P.C. TYPICAL WALL TYPES EXAM ROOMS, TREATMENT ROOMS, OFFICES, RESTROOMS, SCREWS 8' O.C. TO EDGES ANS 12" O.C. TO INTERMEDIATE NOT ALL MAY APPLY STUDS. SUSPENDED CEILING GRID IS SCREW ATTACHED AT 4' &BREAK ROOMS. LION WITH WALLTYPE 4. SEE PLANS. 5816 CARROLLTON AVENUE CENTERS TO THE ELIMINATOR TRACK. NO $CAS INDIANAPOLIS IN 46220 ABBREVIATIONS SCOPE NOTES MORE STRINGENT. ANY MISCELLANEOUS PROTECTED FROM DAMAGE OF ANY KIND. PRINTED MATTER TO THE OWNER AT THE EXISTING CONDITIONS WALL LEGEND OUTSIDE DIAMETER LION UNLESS OTHERWISE NOTED FAX 331717SYMBOL LEGEND TEL A.F.F. ABOVE FINISHED FLOOR FD FLOOR DRAIN OD .255.0468 THE CONTRACTOR SHALL BE RESPONSIBLE ITEMS OR MATERIALS NOT SPECIFICALLY TIME OF SUBSTANTIAL COMPLETION. THE CHARGE ORDERS ACT ACOUSTICAL CEILING TILE FIN FINISH OPNG OPENING UR URINAL KEYED NOTE � CONTRACTORS NOTED, BUT REQUIRED FOR PROPER CONTRACTOR SHALL INSTRUCT THE OWNER O FLOOR OPP OPPOSITE 1 INSTALLATION SHALL BE FURNISHED AND FOR FIELD VERIFYING ALL EXISTING WORK OR OWNER'S REPRESENTATIVE IN THE PROPER EXISTING PARTITIONS TO APP APPROXIMATE FLR REFER SHEET WHERE SHOWN. eeai °O■' RESPONSIBILITIES INSTALLED BY THE CONTRACTOR(S). WHICH IS TO REMAIN, AND DETERMINING PROPER USE OF THE EQUIPMENT FURNISHED RE: ALL SHEETS REMAIN. AWT ACOUSTICAL WALL TREATMENT FT FEET O.H. OPPOSITE HAND VCT VINYL COMPOSITION TILE VERT VERTICAL WHETHER OR NOT IT CAN BE REPAIRED BY THEIR TRADE_ FD FLOOR DRAIN 0 TO 0 OUT TO OUT X WALL TYPE. SEE PLANS FOR LOCATION STAMP RE: ALL SHEETS ALL WORK SHALL BE WARRANTED AND/OR RECONDITIONED TO MATCH AND BLKG BLOCKING VT VINYL TILE SEE THIS. SHEET FOR CONSTRUCTION. EXISTING CONDITIONS SHOWN ON THESE SATISFACTORY, IN MATERIALS AND BLEND WITH NEW MATERIALS AND - - - B.O. BOTTOM OF FE FIRE EXTINGUISHER PLAS LAM PLASTIC LAMINATE GENERAL CONTRACTOR IS TO PROVIDE A DRAWINGS ARE BASED UPON BASE - EXISTING PARTITIONS TO BE SHOULD THERE BE ANY QUESTIONS WORKMANSHIP, FOR A MINIMUM PERIOD COMPONENTS. HE SHALL OBTAIN THE - - - - FEC FIRE EXTINGUISHER CABINET PLWD PLYWOOD W% WITH 'S APPROVAL OF THE SCOPE AND THOROUGH CONSTRUCTION CLEAN-UP AT BUILDING OR OTHER CONSTRUCTION REMOVED. SEE DEMO DRAWING. BOT BOTTOM DOOR NUMBER. REFER TO OWNER REGARDING THE CONTRACT DOCUMENTS, OF ONE (1) YEAR, OR FOR THE PERIOD OF CLOSE-OUT, INCLUDING VACUUMING AND DOCUMENTS MADE AVAILABLE TO THE PS PROJECTION SCREEN W/O WITHOUT DOOR SCHEDULE EXISTING CONDITIONS, AND/OR DESIGN WARRANTY CUSTOMARY, OR STIPULATED FOR, LIMIT O SAID WORK PRIOR TO STARTING CHANGE ORDERS SHALL ALL CONTRACTOR OR SUPPLIER REQUESTS FOR CLEANING ALL CARPETING. ARCHITECT BY THE BUILDING OWNER. CAB CABINET GA GAUGE WB WOOD BASE Preliminary INTENT, THE CONTRACTOR SHALL BE THE TRADE, CRAFT, OR PRODUCT, WHICHEVER SUBSTITUTIONS OF SPECIFIED ITEMS SHALL UNLESS OTHERWISE NOTED, AS-BUILT CAR CARPET GB GRAB BAR QT QUARRY TILE WC WATER CLOSET OFFICE RESPONSIBLE FOR OBTAINING A IS LONGER. THEREFORE, ONLY COMPETENT BE ACCEPTED FOR COMPLETED WORK THAT BE SUBMITTED IN WRITING, ACCOMPANIED DESIGN ARCHITECTURAL CONDITIONS HAVE NOT BEEN NEW PARTITIONS TO BE CJ CONTROL JOINT ROOM NAME, SIZE AND NUMBER. REFER Not For Construction CLARIFICATION FROM THE ARCHITECT PRIOR TO MECHANICS CAPABLE OF PRODUCING GOOD DOES NOT CONFORM TO THE STANDARDS GWB GYPSUM WALLBOARD R RISER WD WOOD '000 BID SUBMITTAL AND PROCEEDING WITH WORKMANSHIP CUSTOMARY TO THE TRADE BY THE ALTERNATIVE PRODUCT INFORMATION FIELD VERIFIED AND MAY VARY FROM THOSE CONSTRUCTED 10-0x14-0 TO ROOM FINISH SCHEDULE ESTABLISHED AT THE TIME OF BID COMPLIANCE REVIEW CL CENTER LINE RA RETURN AIR WH WATER HEATER TO THE ARCHITECT. ALL SUBSTITUTIONS SHOWN. ANY WORK, OR RELATED WORK, IN SHOULD BE USED. COMMENCING WORK ACCEPTANCE. SHALL BE SUBMITTED TO THE ARCHITECT, NO PRIOR TO SUBMITTING THE CONSTRUCTION CMU CONCRETE MASONRY UNIT HDWR HARDWARE RB RESILIENT BASE wp WORKING POINT ELEVATION NUMBER 13 MAY 02 QUESTION. BY A CONTRACTOR OR SUBCONTRACTOR THE CONTRACTOR SHALL BE RESPONSIBLE LATER THAN (10) WORKING DAYS PRIOR TO RE: ALL SHEETS BID, THE CONTRACTOR SHALL BE DESIGMTES INTERIOR WALL CONST. COL COLUMN HM HOLLOW METAL REF REFERENCE A( - CONSTITUTES ACCEPTANCE OF THE FOR FAMILIARIZING HIMSELF WITH THE BID OPENING DATE. SUBSTITUTIONS SHALL ONLY RESPONSIBLE FOR FIELD VERIFYING ALL X TYPES. REFER TO FLOOR PLANS FOR CONC CONCRETE HORIZ HORIZONTAL REFR REFRIGERATOR THESE CONTRACT DOCUMENTS ARE CONDITIONS AND SURFACE CONCERNED. IF PROJECT SCOPE OF WORK, BUILDING BE CONSIDERED ONLY IF THEY DO NOT THE CONTRACTOR SHALL SUBMIT SHOP EXISTING CONDITIONS AND ANY CRITICAL LOCATIONS. REFER TO WALL TYPES ON CONST CONSTRUCTION HVAC HEATING, VENTILATING, AIR COND. SHEET NUMBER INTENDED TO DESCRIBE ONLY THE SCOPE ANY SUCH CONDITIONS ARE UNACCEPTABLE, DRAWINGS OF CUSTOM MILLWORK, CUSTOM READ REQUIRED STANDARDS, SCHEDULE AND DEADLINES. SACRIFICE QUALITY, APPEARANCE, AND DIMENSIONS ASSOCIATED WITH THE THIS SHEET FOR ACTUAL WALL CONSTRUCTION. CONT CONTINUOUS HW HOT WATER RO ROUGH OPENING AND APPEARANCE OF THE REAL PROPERTY THE GENERAL CONTRACTOR SHOULD BE THE CONTRACTOR SHALL FURTHER BE FUNCTION. UNDER NO CIRCUMSTANCES WILL FABRICATION OR MANUFACTURE, AND PROPOSED WORK. THE CONTRACTOR SHALL AND NUMBER mi IMPROVEMENTS, INCLUDING THE NOTIFIED AT ONCE AND NO WORK DONE PHYSICAL SAMPLES OF ALL FINISH NOTE: ALL WALLS ARE W1 UNLESS CT CERAMIC TILE JST JOIST - RESPONSIBLE FOR ADVISING THE OWNER OF THE OWNER BE REQUIRED TO PROVE THAT A CONFIRM THAT ALL WORK OUTLINED WITHIN W PERFORMANCE AND LEVEL OF QUALITY UNTIL CONDITIONS ARE ACCEPTABLE. ALL LONG LEAD TIME ITEMS AFFECTING THE PRODUCT PROPOSED FOR SUBSTITUTION IS OR MATERIALS SPECIFIED TO THE ARCHITECT FOR THESE DOCUMENTS MAY BE ACCOMPLISHED OTHERVISE NOTED. CW COLD WATER JT JOINT SA SUPPLY AIR EXPECTED OF ITS COMPONENTS. IT IS REVIEW AND APPROVAL BY THE OWNER. SHEET NUMBER PROJECT SCHEDULE AND SHALL UPON IS NOT OF EQUAL QUALITY TO THE PRODUCT AS SHOWN, PRIOR TO THE COMPLETION OF SCHED SCHEDULE INCUMBENT UPON THE CONTRACTOR TO THE CONTRACTOR SHALL COORDINATE WITH DET DETAIL KIT KITCHEN INSURE THAT ALL WORK COMPLETED AND THE OWNER, OR THEIR AUTHORIZED AGENT, REQUEST FROM THE OWNER, SUBMIT ORDER SPECIFIED. THE BIDDING PROCESS, AND SHALL NOTIFY SEC SECTION X ENLARGED PLAN CONFIRMATIONS AND DELIVERY DATES FOR REVIEWED SHOP DRAWINGS AND BOTH THE ARCHITECT AND THE BUILDING DF DRINKING FOUNTAIN LAM LAMINATE �000ac MATERIALS INSTALLED BE IN FULL TO DETERMINE ALL EXISTING MATERIALS TO SUCH LONG LEAD TIME ITEMS TO THE UNDER NO CIRCUMSTANCES SHALL THE SCHEDULES PREPARED BY OTHERS SHALL NOT OWNER OF ANY CONDITIONS ENCOUNTERED DIM DIMENSION SIM SIMILAR ---, COMPLIANCE, AS A MINIMUM STANDARD, BE SALVAGED AND RETAINED BY THE OWNER. CONTRACTOR SCALE THE DRAWINGS TO BE CONSTRUED TO BE PART OF THE WHICH MAY EFFECT BUILDING CODE LAV LAVATORY SPECS SPECIFICATIONS WITH ALL APPLICABLE CODES, DWG DRAWING REGULATIONS OWNER. THE CONTRACTOR SHALL REMOVE DETERMINE THE DIMENSIONS. SEE FLOOR CONTRACT DOCUMENTS, AS THE ARCHITECT COMPLIANCE. LIFE SAFETY AND ISSUANCE LLH LONG LEG HORIZONTAL SF SQUARE FOOT 1 1 AND ORDINANCES HAVING JURISDICTION. SALVAGEABLE MATERIALS FROM THE SPACE THE CONTRACTOR SHALL COORDINATE WITH PLAN FOR DIMENSION LOCATIONS. ASSUMES NO RESPONSIBILITY FOR OF A CERTIFICATE OF OCCUPANCY, THE DWC DRINKING WATER COOLER LLV LONG LEG VERTICAL SA SUPPLY AIR------� AND STORE IN A LOCATION AS DIRECTED BY THE BUILDING OWNER ACCESS TO THE DRAWINGS, SCHEDULES AND/OR TIMELY COMPLETION FOR THE PROJECT OR EA THESE CONTRACT DOCUMENTS DO NOT THE OWNER. ALL OTHER MATERIALS , SPACE AND THE ONGOING CONSTRUCTION THE CONTRACTOR SHALL BE RESPONSIBLE SPECIFICATIONS FOR WORK ON THE PROJECT ESTABLISHED BUDGET OF SUCH WORK. EACH MAS MASONRY SS STAINLESS STEEL O FINISH NOTE. REFER TO ROOM EJ EXPANSION JOINT z FLLJ — ATTEMPT TO INSTRUCT THE CONTRACTOR IN RUBBISH, AND DEBRIS, SHALL BE REMOVED WORK. DISRUPTIVE OR POTENTIALLY FOR THE INSTALLATION OF ALL SELECTED PREPARED OR ACCOMPLISHED BY OTHERS. MAX MAXIMUM STD STANDARD FINISH LEGEND C) W THE DETAILS OF HIS TRADE. THEY ARE AND PROMPTLY DISPOSED OF BY THE HAZARDOUS CONSTRUCTION ACTIVITIES SHALL MATERIALS WHICH SHALL BE COMPLETE IN NO ADDITIONAL FUNDS WILL BE APPROVED EL ELEVATION MB MARKER BOARD STL STEEL U CV PERFORMANCE SPECIFICATIONS IN THAT THEY CONTRACTOR AT AN OFFSITE LOCATION. THE BE COORDINATED TO OCCUR AFTER NORMAL ALL RESPECTS PRIOR TO THE FINAL THE ARCHITECT WILL REVIEW THE FOR WORK OMITTED FROM THE EIFS EXTERIOR INSULATION FINISH SYSTEM SUSP SUSPENDED © REVISION CA DO REQUIRE THAT ALL MANUFACTURED CONTRACTOR SHALL TAKE ALL NECESSARY OFFICE HOURS, SO AS TO MINIMIZE ACCEPTANCE, UNLESS OTHERWISE NOTED. DRAWINGS AND SAMPLES FOR CONFORMITY CONSTRUCTION BID DUE TO LACK OF EXIS EXISTING MECH MECHANICAL L t- O ITEMS, MATERIALS AND EQUIPMENT BE PRECAUTIONS TO ASSURE THAT ALL PROPERTY DISTURBANCE TO BUILDING OCCUPANTS. WITH THE INFORMATION CONTAINED IN THE VERIFICATION BY THE CONTRACTOR, EXCEPT MEZZ MEZZANINE TB TACK BOARD Q INSTALLED IN STRICT ACCORDANCE WITH THE IMPROVEMENTS I.E., PARTITIONS, DOORS, CONSTRUCTION DOCUMENTS, AND RETURN EXP EXPANSION ELEVATION TARGET � THE CONTRACTOR SHALL PRESERVE ALL AS OTHERWISE APPROVED BY THE OWNER MFR MANUFACTURER TEL TELEPHONE � �' Z MANUFACTURER'S �- RECOMMENDED FRAMES, CABINETS, CEILING GRID, CEILING THE CONTRACTOR SHALL COORDINATE WITH PRINTED INSTRUCTIONS AND WARRANTIES THE SUBMITTALS TO THE CONTRACTOR WITHIN FOR WORK ASSOCIATED WITH "HIDDEN" EXT EXTERIOR MIN MINIMUM T.O. TOP OF a J < Q SPECIFICATIONS, EXCEPT IN THE CASE TILE, AND THE ELECTRICAL AND MECHANICAL THE BUILDING OWNER FOR DELIVERY TO THE THAT ARE PROVIDED WITH EQUIPMENT OR FIVE (5) WORKING DAYS OF RECEIPT, CONDITIONS NOT ACCESSIBLE PRIOR TO SEMI-RECESSED FIRE EXTINGUISHER WHERE THE CONTRACT DOCUMENTS ARE DEVICES, ETC.] WHICH ARE TO REMAIN, ARE SPACE OF ALL BUILDING MATERIALS. MATERIALS USED, AND DELIVER SAID EXCEPT AS MAY OTHERWISE BE PROVIDED CONSTRUCTION_ M.O. MASONRY OPENING TV TELEVISION F E CABINET TO BE PROVIDED/INSTALLS BY U 0 z G.C., SEE DETAIL THIS SHEET. FOR BY THE OWNER. TYP TYPICAL PAINT CABINET TO MATCH DOOR FRAMES. CO2 LL Q 0LU z SHEET INDEX DOCUMENT APPROVAL y �_ LOCATION h16TH ST. zm TITLE SHEET W INDEX SHEET A431 ST %TH T. a z TO CHICAGO cc A1.1 AREA '400' FLOOR PLAN 86TH ST. CLIENT/TENANT DATE A2.1 AREA '400' REFLECTED CEILING PLAN G T C" 3" VENT THRU AREA '400' ELECTRICAL PLAN Q ROOF,q A3.1 ENLARGED PLANS & ELEVATIONS o� TITLE V T I A4.1 AREA '400' FINISH PLAN & SCHEDULE ' AVRENCE W 1 1/2" REVENT 11911 465 J THRU N. MERIDIAN STREET , W TH ST. 38TH S . 3' VENT ROOF I M PROPERTY MANAGER DATE =>N 9y� 465 - L m SPEEDW LLJ W Q N I 1 1/2- REVENTN. O a 1 TH ST N IHGTI♦+ ST. CARSON DESIGN ASSOCIATES DATE � Z 0 I a Ofo ❑ IS AVEy d UPON EXECUTION, THE CLIENT AND PROPERTY 1 o o A E 74 MANAGER APPROVE ALL ASPECTS OF THE SCOPE z z TO ST. L OF WORK SHOWN IN THESE DOCUMENTS, INCLUDING �V 3" ( 65 IHOMPSM Ra r, DESIGN CONTENT, SCOPE OF CONSTRUCTION AND 3" �FINISH SELECTION FOR THE FOLLOWING PHASE: 3. LAV 3- 3- i J / - LAV I / 5 SPACE PLANNING TO EXIST. ISSUE: 1-1 WHP THPORT STORT RA ci °F1PRELIMINARY PRICING 13 MAY 02 BID PRICING SET CDG SAN. MAIN TO EXIST. 3' b DOUBLE COMPARTMENT SINK SAN. MAIN /) C�� TO LOUISVILLE � � CONSTRUCTION DOCUMENTATION NOTE: SEE PLAN FOR LOCATIONS OF SINKS. w.c. ❑ METROPOLITAN INDIANAPOLIS SINGLE/DOUBLE ALL COSTS INCURRED DUE TO MISINTERPRETATION OF THESE DOCUMENTS OR ANY CHANGES TO THE COMPARTMENT SINK ISOMETRIC SANITARY WASTE ISOMETRIC S MAP VICINITY MAP PROJECT REQUESTED AFTER SIGN -OFF SHALL NOT BE THE RESPONSIBILITY OF CARSON DESIGN ORTH ASSOCIATES AND SHALL BE THE SOLE sc N.T.S. NO ale NO SCALE NO SCALE RESPONSIBILITY OF THE CLIENT. REFER TO FLOOR PLANS FOR WALL TYPES. ANY EXISTING CONSTRUCTION (WALL, REFER TO FLOOR PLANS FOR TYPE COLUMN WRAP, ETC) TO REMAIN. _ NEW DOOR FRAME. REFER TO DOOR FINISH SCHEDULE FOR TYPE OR USE NEW OR EXISTING WINDOW MULLION METAL STUD RUNNER BETWEEN VERT STUDS. BUILDING OWNER STANDARDS_ BLACK NEOPRENE SEAL ADHERED TO FACE OF NEW INTERIOR WALL CONSTRUCTION. MULLION AND SILL CAP AT ALL EXPOSED REFER TO FLOOR PLANS FOR TYPE. MATCH NEW WALL TYPE UNLESS OTHERWISE NOTED OR SURFACES ADJACENT TO ALUMINUM CHANNEL. WITH EXISTING WALL DIMENSIONED ALIGN FACE OF ANY NEW c� REFER TO FLOOR CODEGPILANS FOR INET CONSTRUCTION TO REMAIN. CONSTRUCTION WITH FACE OF ADJACENT FIRESEMI RECESSED EXTINGUISHEREXISTING CONSTRUCTION TO REMAIN. z LOCATIONS. ANCHOR CABINET TO DOUBLE oSTUDS AT JAMBS. NEW INTERIOR WALL CONSTRUCTION. ALUMINUM BRAKE METAL CHANNEL W/EDGES = REFER TO FLOOR PLANS FOR TYPE RETURNED (COLOR TO MATCH WINDOW FRAMING o I SYSTEM). SQUARE FOOTAGE: ANY EXISTING CONSTRUCTION (WALL., EDGE OF SILL BELOW. NEW DOOR FRAME. REFER TO DOOR COLUMN WRAP, ETC) TO REMAIN. CL WOOD SHIMS AS REQ'D AT SILL & JAMBS. EXISTING COLUMN FINISH SCHEDULE FOR TYPE OR USE o BUILDING OWNER STANDARDS. WITH WRAP. DRAWING TITLE: a o NEW INTERIOR WALL CONSTRUCTION. INDEX - WALL CONSTRUCTION (REF. TO FLOOR PLAN) REFER TO FLOOR PLANS FOR TYPE. CENTERED ON WINDOW MULLION z UNLESS OTHERWISE NOTED OR UNLESS OTHERWISE NOTED DIMENSIONED ALIGN FACE OF ANY NEW Typ.Details0ALIGN FACE OF ANY NEW CONSTRUCTION WITH FACE OF ADJACENT NOTE; UNLESS OTHERWISE NOTED OR DIMENSIONED ON PLANS PROVIDE CONSTRUCTION WITH FACE OF EXISTING CONSTRUCTION TO REMAIN_ NOTE; PROVIDE TIGHT FIT WHERE WALL IS COPED 4" OF SPACE AT HINGE SIDE OF ALL DOOR FRAMES. ADJACENT COLUMN WRAP FIN FACE. Typ,lnfo. NEW INTERIOR WALL CONSTRUCTION. AROUND ANY WINDOW SILL CONSTRUCTION. REFER TO FLOOR PLANS FOR TYPE JOB NO. DATE: SEMI-RECESSED F.E. CABINET ID TYPICAL DOOR JAMB REQUIREMENTS 1 C TYPICAL WALL ALIGNMENT PLAN 1 B TYPICAL WALL @ MULLION DETAIL 1A NO SCALE NO SCALE NO SCALE NO SCALE in= TYPICAL DETAILS NOT ALL MAY APPLY 1SHEET NUMBER: NO SALE INDEX GENERAL FLOOR PLAN NOTES i NOT ALL MAY APPLY. REFER TO PLANS FOR ADDITIONAL NOTES AND INFORMATION. 5' 1. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS, JOB CONDITIONS, ETC. 2'-6' 2'-6" 2. ALL DIMENSIONS ON PLANS ARE TO FACE OF MTL STUD WALL, CONCRETE MASONRY UNIT OR BRICK. 4' 11' 3. WHERE DISSIMILAR FLOOR MATERIALS MEET THEY SHALL DO SO UNDER THE CENTERLINE - _ CUSTOM UPPER CABINET. OF THE DOOR, UNLESS NOTED OTHERWISE. 5 4. PROVIDE DEEP LEG TRACKS AT ALL METAL STUD CONNECTIONS TO STRUCTURE ABOVE. UNLESS NOTED OTHERWISE. 5. HINGE SIDE OF DOOR JAMBS IN METAL STUD WALLS WILL TYPICALLY BE LOCATED 4" FROM ADJACENT WALL. N \ / \ / t * UNLESS NOTED OTHERWISE. SEE TYPICAL DETAILS ON INDEX SHEET FOR ADDITIONAL INFORMATION. - - - - ---- ------ o -o ------ 6. PROVIDE BLOCKING IN NEW METAL STUD WALLS FOR ALL WALL SUPPORTED ITEMS. 7. PROVIDE FIRE STOPPING AT PENETRATIONS OF ALL RATED WALLS. t0 � 1 8. SEE REFLECTED CEILING PLANS FOR BULKHEAD LOCATIONS AND ASSOCIATED DETAIL REFERENCES. M 6 6 9. REFER TO DEMOLITION PLAN FOR ALL REQUIRED DEMOLITION WORK. PLASTIC LAMINATE COUNTERTOP41.1 1YP 43.1 10. REFER TO ROOM FINISH SCHEDULE FOR ALL REQUIRED FINISH INFORMATION. �., 11. REFER TO DOOR SCHEDULE FOR ALL DOOR AND FRAME TYPES, HARDWARE INFORMATION AND ALL OTHER DOOR �, EXAM 4 INFORMATION. EXAM 1 EXAM 2 413 412 1 R.R. 12. WHERE NEW WALL CONSTRUCTION IS SHOWN ABUTTING WINDOW MULLIONS, CENTER WALL CONSTRUCTION ON MULLION CUSTOM BASE CABINET. 415 414 1 i 411 BREAK REFER TO TYPICAL DETAILS ON INDEX SHEET FOR ADDITIONAL CONSTRUCTION INFORMATION. 4, ROOM 13. WHERE NEW WALL CONSTRUCTION IS REQUIRED ADJACENT TO OR ABUTTING EXISTING CONSTRUCTION ALIGN FACE EQ. EQ. 410 OF NEW CONST. WITH FACE OF EXISTING CONST. SEE TYPICAL DETAILS ON INDEX SHEET FOR ADDITIONAL INFORMATION. 14. ALL FINISHES SHALL CONFORM TO CHAPTER 42 OF THE INDIANA BUILDING CODE. �, OPEN 15. WHERE POSSIBLE LEAVE 1'-6' OF UNOBSTRUCTED SPACE ON LATCH/PULL SIDE OF ALL DOORS AND / \ � \ F 1 N 412 1 1 1'-0" OF UNOBSTRUCTED SPACE ON LATCH/PUSH SIDE OF DOORS FOR A.D.A. COMPLIANCE. 16. USE ONLY PLENUM RATED CABLE. / \ +ts 4t+ 1 ata Ott { 4t0A 17. THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS SCOPE OF WORK TO DISCONNECT AND RECONNECT 00 AJI TENANT'S EXISTING POWERED SYSTEMS FURNITURE. IF TENANT IS INSTALLING NEW POWERED SYSTEMS FURNITURE 2'-6" 2'-6" r 3/A1.1 �'----- 3'-6" 5/A1.1 �`----------- 2 ELECTRICAL CONTRACTOR SHALL INCLUDE PRICE TO CONNECT. 5''� 2 HAS i� 18. UNLESS OTHERWISE NOTED ALL INTERIOR WALLS WILL BE TYPE #2. SEE WALL TYPES ON INDEX SHEET FOR 19. PRI DDITIONAL INFO. ,�.1 403 PROVIDE CONTROL JOINTS IN ALL RUNS OF METAL STUD/GYP BD WALLS OVER 30' IN LENGTH. COORDINATE CHECK-OUT _- - SIM. 16'-8' LOCATIONS WITH CARSON DESIGN ASSOCIATES PRIOR TO INSTALLATION FOR COMPLIANCE WITH DESIGN INTENT. 8 7 400 --- 20. PROVIDE NEW BLDS. STANDARD BUNDS 0 EXTERIOR WINDOWS AS REQUIRED. 41.1 41.1 - C HALL PLAN KEYNOTES F.E.C. 408 A1.1 4 ao� ; ELEVATION 6/ _j -1 1/2'-1-0 M 1 4 EXAM O Ol EXISTING WALL, PROVIDE ONE LAYER OF 5/8" GYPSUM BOARD ON TENANT SIDE. N NUBS 431 407 O2 REMOVE jNDOW, FRAME, AND WALL BELOW. PROVIDE NEW DOOR, FRAME, SIDELITE, AND HARDWARE. REFER TO KEY- o� NOTE 5 BELOW FOR EXISTING DOOR AND SIDELITE TO MATCH IN IT'S ENTIRETY. FINISH ENDS OF WALL EXPOSED 8 2 -•� 4'_g^ 1 (5 EQUAL 2 DR. CABINETS) 14'-8" 1 3 DURING DEMOLITION. HARDWARE TO BE PUSH/PULL, CLOSER, & DEADBOLT (3 BOLTS). 1'-1 " PROVIDE GYPSUM BOARD BULKHEAD. 3 REFER TO DETAIL 1A ON INDEX SHEET. PROVIDE WHITE MELAMINE ON ALL M RETURN TRANSACTION TOP AROUND CORNER, OVERHANG TO BE EQUAL TO FRONT OVERHANG. � i � ------- - EXPOSED SURFACES OF CABINET AND CABINET DOOR TO RECEIVE PLASTIC BACK SIDE OF CABINET DOOR. LAMINATE ON ALL EXPOSED SURFACES 1 /A3.1 __�� 5 MATCH THIS DOOR, FRAME, SIDELITE. &HARDWARE. / O BUSINESS 3/4" MDF ADJUSTABLE WHITE MELAMINE OFFICE O WORK COUNTER, REFER TO 3/A3.1. SHELVES ON RECESSED SHELF O OFFICE STANDARDS. 1 r 9 O 409 HARDWARE TO BE WIRE PULLS. TREADMILV t ECHO HALL EXAM 6 1" DEEP FLOURESCENT LIGHT FIXTURE. 404 405 06 i HUBBELL 01 SERIES (120 VOLT). 6 416 3/4" PARTICLE BOARD COVERED WITH TEL CLOSET �., 2'-0" PLASTIC LAMINATE. 1 416 N PROVIDE WHITE MELAMINE ON ALL i EXPOSED SURFACES OF DRAWER. 4'- ^ 1 8" 4'- HARDWARE TO BE WIRE PULLS. 12 10 1 3' CABINET DOOR TO RECEIVE PLASTIC 3/4" MDF ADJUSTABLE WHITE MELAMINE LAMINATE ON ALL EXPOSED SURFACES _ SHELVES ON RECESSED SHELF o --------------------------------- - STANDARDS. PROVIDE WHITE MELAMINE ON ALL EXPOSED SURFACES OF CABINET AND BACK SIDE OF CABINET DOOR. NOTE; PLUMBING LEGEND _ -------------------------I --1. ALL ANGLED WALLS TO BE PERPENDICULAR OR PARALLEL TO EXISTING WALL NOTED IN KEYNOTE 1 ON SHEET 41.1. FOR MILLWORK FIXTURES ONLY. REFER TO PLAN DETAILS FOR ALL OTHER FIXTURES. NOTE: 2. ALL EXAM ROOM (406, 407, 412, 413, 414, & 415) MILLWORK TO BE 6/A1.1 OR OPP. HAND. 1. PROVIDE WOOD BLOCKING AS REQUIRED. *O DOUBLE BOWL SINKS- ELKAY CR -3321 33x21 DOUBLE BOWL SINK WITH RINSING BASKET. 2. PROVIDE 1/4" CHAMFER ALONG FRONT 3. REFER TO 5/41.1 TYPICAL RESTROOM PLAN FOR R.R. 411 DIMENSIONS &EQUIPMENT IDENTIFICATIONS. F4UCET- DELTA 400 EDGE OF COUNTER TOP.O GyRBAGE DISPOSAL TYPE- INSINKERATOR BADGER 1. I AREA 400 FLOOR PLAN 1/A1 .1 SECTION 7/A1 .1 1/4"= V-011 3/4* = 11v NORTH 2'-0" 3/4" X 3' CONT. WOOD BLOCKING. 1/4' 3/4' DOOR SCHEDULE 3/4' PARTICLE BOARD COVERED 4' DOOR FRAME WITH PLASTIC LAMINATE. SEE ROOM WOOD TRIM FINISH SCHEDULE. CHAMFER EDGE. NO. TYPE SIZE MATERIAL FINISH I`ATING MATERIAL FINISH TYPE RATING HEAD JAMB HDWRE. REMARKS AREA '300' WOOD CASING WRAPPED PROVIDE BACKSPIASH WHERE SHOWN. WOOD CASING WRAPPED AROUND ENTIRE OPENING 400 2 3-0 x 7-0 Solid Wood/Glass Stain -- Wood Stain 2 -- H1 J1 3 SEE NOTE 2 C14 ROUTE OUT UNDERSIDE OF TOP TO AROUND ENTIRE OPENING LEAVE A 1/4" THICK SCRIBE. DOOR STOP SUPPLIED FELT PADS, PROVIDE A ' FIELD TRIM AS REQUIRED TO WHEN NECESSARY NEOPRENE PAD AT BOTTOM 404 1 3-0 x 7-0 Solid Wood Pre -finished -- Timely Pre -finished 1 -- -- -- 1 SEE NOTE 4 PROVIDE TIGHT FIT ALONG WALL. ------------------------ ------- - 1/4' CLEAR GLASS 406 1 3-0 x 7-0 Solid Wood Pre -finished -- Timely Pre -finished 1 -- -- -- 1 SEE NOTE 4 f WOOD TRIM GLASS STOP407 1 3-0 x 7-0 Solid Wood Pre -finished -- Timely Pre -finished 1 -- -- -- 1 SEE NOTE 4 O PROVIDE ON BOTH SIDES / 3/4' X 3- CONT. WOOD BLOCKING. DOOR (REFER TO 409 1 3-0 x 7-0 Solid Wood Pre -finished -- Timely Pre -finished 1 -- -- -- 4 / AREA 400 '/ DOOR SCHEDULE) HEAD - H1 4104 1 3-0 x 7-0 Solid Wood Pre -finished -- Timely Pre -finished 1 -- -- -- 1 � 1/4- 3/4' 1" X 4" SOLID OAK TOP PLATE. 4* 410B SEE NOTE 3 O CENTER ON VERTICAL SUPPORT LEG. M WOOD TRIM *10 TYPICAL AT EACH LEG. PLACE 411 1 3-0 x 7-0 Solid Wood Pre -finished -- Timely Pre -finished 1 -- -- -- 2 ` \ BETWEEN FRONT &BACK BLOCKING. AREA 200 ANCHOR COUNTERTOP TO THIS PLATE. WOOD CASING WRAPPED AROUND ENTIRE OPENING 412 1 3-0 x 7-0 Solid Wood Pre -finished -- Timely Pre -finished 1 -- -- -- 1 SEE NOTE 4 ' W CL 3" OP. PENCIL DRAWER OF HARDWOOD WDOOR STOP SUPPLIED 413 1 3-0 x 7-0 Solid Wood Pre -finished -- Timely Pre -finished 1 -- -- -- 1 SEE NOTE 4 MOUNTED TO UNDERSIDE OF WORKSURFACE cn J WHEN NECESSARY PLASTIC LAMINATE ON ALL EXPOSED a SURFACES (PL -2), WHITE MELAMINE 414 1 3-0 x 7-0 Solid Wood Pre -finished -- Timely Pre -finished 1 -- -- -- 1 SEE NOTE 4 \ AREA f 1 001 ON DRAWER INTERIOR. PROVIDE WIRE PULL 3/4" PARTICLE BOARD END PANEL FINISH TO MATCH COUNTERTOP 415 1 3-0 x 7-0 Solid Wood Pre -finished -- Timely Pre -finished 1 -- -- -- 1 SEE NOTE 4 ABOVE. DOOR (REFER TO PROVIDE 2' DIA. GROMMETS (COLOR: JAMB - J1 DOOR SCHEDULE) 416 1 3-0 x 7-0 Solid Wood Pre -finished -- Timely Pre -finished 1 -- -- -- 1 BLACK) PLACE 4- FROM BACK OF WALL NOTE: EASE ALL EXPOSED EDGES. TO CENTER OF GROMMETS DOOR SCHEDULE NOTES DOOR TYPES FRAME TYPES KEY PLAN 2/A1 .1 SECTION 8/Al a I JAMB DETAIL 4041 ■1 1 . DON, ALL DOORS WILL BE BIRCH WITH A TIMELY FRAME. FRAME FINISH TO DOOR WIDTH NO SCALE 11/2' =1'-0' 3' =1'-O' BE NAVAJO WHITE (SC104). HARDWARE WILL HAVE A 26D FINISH. 2. NEW MAPLE DOOR AND FRAME. STAIN TO MATCH PLASTIC LAMINATE; NEVAMAR, CARMEL SAGAWOOD, #RIM -8-350. SEE SCHED. SEE SCHED. DOOR WIDTH '00 ❑ 5 8 4 3. NEW DOOR AND FRAME WITH SIDEUTE, REFER TO KEYNOTE 2 ON SHEET A1.1. 6 3 PLAN KEYNOTES 4. PROVIDE A COAT HOOK WITH BUMPER, BOBRICK MODEL B-212, MOUNT 0 H1 7 NOTE; DIMENSIONS ARE FROM FINISH FACE OF WALL TO CENTERLINE OF FIXTURE. UON. 4 -6 AFF TO HOOK AND HORIZONTALLY CENTERED ON DOOR. 5' J1 ORECESSED PAPER TOWEL DISPENSER/DISPOSAL UNIT. MOUNT 0 50' TO TOP. BOBRICK B-36903. HARDWARE LEGEND 2 O2 SURFACE MOUNTED SOAP DISPENSER. MOUNT VERTICALLY SO CENTERLINE OF CONTROL IS AT 48" AFF. �w �w HOD BOBRICK B-2112. SUPPLIED BY TOILET PAPER/ SOAP VENDOR. HARDWARE SET /1 HARDWARE SET 2 HARDWARE SET ll3 HARDWARE SET #4 N N U.1 Uj = _ O3 ADA COMPLIANT, WALL MOUNTED LAVATORY. MOUNT AT 34' TO RIM. AMERICAN STANDARD COMRADE SPS 3 HINGES 3 HINGES 3 HINGES 3 HINGES C) C) 0124 WHITE. INSULATE HOT WATER & DRAIN LINES. PROVIDE A DELTA 2529-HDF FAUCET WITH METAL cWn vwi o 0 1 PASSAGE LATCH 1 PRIVACY LOCK 1 ENTRANCE/ 1 ENTRAACE/ o 2'-2' GRID STRAINER. 1 BUMPER 1 BUMPER OFFICE LOCK OFFICE LOCK O4 WALL MOUNTED MIRROR. MOUNT BOTTOM AT 40' AFF CENTERED OVER SINK. BOBRICK B-166 2430. 3 MUTES 3 MUTES 1 CLOSER 1 BUMPER 7' 1'-6' 1 1 BUMPER 3 MUTES O5 ADA COMPLIANT, FLOOR MOUNTED WATER CLOSET. AMERICAN STANDARD CADET SPS 2168.100 PRESSURE 3 MUTES ASSISTED! 1 DEADBOLT N 1 1/2" DIA S.S. GRAB BARS WITH SNAP FLANGES. BOBRICK B-6137. MOUNT SO CENTERLINE IS 6S AT 36 AFF. tu U Li i� 77 SURFACE MOUNTED MULTI -ROLL TOILET TISSUE DISPENSER. MOUNT 0 28' AFF TO TOP. MOUNT TYPE 1 TYPE TYPE 1 TYPE 1 C14 I _ HORIZONTALLY AT 36" FROM FACE OF BACK WALL TO FRONT EDGE OF PAPER ROLL BOBRICK B-2888. HARDWARE NOTES: SEE DETAIL 4/A1.1 � 7 COLUIr+N SUPPLIED BY TOILET PAPER/ SOAP VENDOR. O8 NEW WALL FURRING FOR PLUMBING. FURRING TO BE 3 5/8' METAL STUDS 0 16' O.C. WITH ONE REQUIRED TYPE PER SITUATION AND LOCATION OF DOOR. 1. BUMPER TO BE A WALL OR FLOOR MOUNTED BUMPER. PROVIDE LAYER OF 5/8* GYPSUM BOARD. 2. ALL NEW DOORS TO RECEIVE BUILDING STANDARD LEVER HANDLES. 3 5/8' METAL STUDS WITH 5/8' GYPSUM BOARD ONE SIDE. STEEL COLUMN. COLUMN TYPICAL RESTROOM PLAN 5/41 ■1 ENLARGED COLUMN 3041 a 1/2'=1'-0' 1'=1'-0' CARSON DESIGN ASSOCIATES TEL 317.843.5979 FAX 317.8435975 11590 N. MERIDIAN SURE 104 CARMEL INDIANA 46032 TEL 512.977.0520 FAX 512.977.0384 4201 W. PARMER LANE SURE 104 AUSTIN TEXAS 78727 www. DAVID POWERS ARCFNTECT, P.C. 5816 CARROLLTON AVENUE INDIANAPOLIS IN 46220 TEL 317.627.5820 FAX 317.255.0468 wrWk pawwsarchplan@aol.aom STAMP Preliminary Not For Construction 13 MAY 02 mi W O101/ V-6' 2'-9' -1'-3- '-3"5'-6" 0 � 0 i N to 5'- 6 NOTE; DIMENSIONS ARE FROM FINISH FACE OF WALL TO CENTERLINE OF FIXTURE. UON. 4 -6 AFF TO HOOK AND HORIZONTALLY CENTERED ON DOOR. 5' J1 ORECESSED PAPER TOWEL DISPENSER/DISPOSAL UNIT. MOUNT 0 50' TO TOP. BOBRICK B-36903. HARDWARE LEGEND 2 O2 SURFACE MOUNTED SOAP DISPENSER. MOUNT VERTICALLY SO CENTERLINE OF CONTROL IS AT 48" AFF. �w �w HOD BOBRICK B-2112. SUPPLIED BY TOILET PAPER/ SOAP VENDOR. HARDWARE SET /1 HARDWARE SET 2 HARDWARE SET ll3 HARDWARE SET #4 N N U.1 Uj = _ O3 ADA COMPLIANT, WALL MOUNTED LAVATORY. MOUNT AT 34' TO RIM. AMERICAN STANDARD COMRADE SPS 3 HINGES 3 HINGES 3 HINGES 3 HINGES C) C) 0124 WHITE. INSULATE HOT WATER & DRAIN LINES. PROVIDE A DELTA 2529-HDF FAUCET WITH METAL cWn vwi o 0 1 PASSAGE LATCH 1 PRIVACY LOCK 1 ENTRANCE/ 1 ENTRAACE/ o 2'-2' GRID STRAINER. 1 BUMPER 1 BUMPER OFFICE LOCK OFFICE LOCK O4 WALL MOUNTED MIRROR. MOUNT BOTTOM AT 40' AFF CENTERED OVER SINK. BOBRICK B-166 2430. 3 MUTES 3 MUTES 1 CLOSER 1 BUMPER 7' 1'-6' 1 1 BUMPER 3 MUTES O5 ADA COMPLIANT, FLOOR MOUNTED WATER CLOSET. AMERICAN STANDARD CADET SPS 2168.100 PRESSURE 3 MUTES ASSISTED! 1 DEADBOLT N 1 1/2" DIA S.S. GRAB BARS WITH SNAP FLANGES. BOBRICK B-6137. MOUNT SO CENTERLINE IS 6S AT 36 AFF. tu U Li i� 77 SURFACE MOUNTED MULTI -ROLL TOILET TISSUE DISPENSER. MOUNT 0 28' AFF TO TOP. MOUNT TYPE 1 TYPE TYPE 1 TYPE 1 C14 I _ HORIZONTALLY AT 36" FROM FACE OF BACK WALL TO FRONT EDGE OF PAPER ROLL BOBRICK B-2888. HARDWARE NOTES: SEE DETAIL 4/A1.1 � 7 COLUIr+N SUPPLIED BY TOILET PAPER/ SOAP VENDOR. O8 NEW WALL FURRING FOR PLUMBING. FURRING TO BE 3 5/8' METAL STUDS 0 16' O.C. WITH ONE REQUIRED TYPE PER SITUATION AND LOCATION OF DOOR. 1. BUMPER TO BE A WALL OR FLOOR MOUNTED BUMPER. PROVIDE LAYER OF 5/8* GYPSUM BOARD. 2. ALL NEW DOORS TO RECEIVE BUILDING STANDARD LEVER HANDLES. 3 5/8' METAL STUDS WITH 5/8' GYPSUM BOARD ONE SIDE. STEEL COLUMN. COLUMN TYPICAL RESTROOM PLAN 5/41 ■1 ENLARGED COLUMN 3041 a 1/2'=1'-0' 1'=1'-0' CARSON DESIGN ASSOCIATES TEL 317.843.5979 FAX 317.8435975 11590 N. MERIDIAN SURE 104 CARMEL INDIANA 46032 TEL 512.977.0520 FAX 512.977.0384 4201 W. PARMER LANE SURE 104 AUSTIN TEXAS 78727 www. DAVID POWERS ARCFNTECT, P.C. 5816 CARROLLTON AVENUE INDIANAPOLIS IN 46220 TEL 317.627.5820 FAX 317.255.0468 wrWk pawwsarchplan@aol.aom STAMP Preliminary Not For Construction 13 MAY 02 mi W 2 a C3 � OW y J CE CV W Q � o Q Q Q Q UCJ o Q � LU W 0 CA >_ Ca z o :5 G T Q C ISSUE: 13 MAY 02 BID PRICING SET CDG SQUARE FOOTAGE: 2,632 RSF DRAWING TITLE: AREA'400' FLOOR PLAN JOB NO. DATE: SHEET NUMBER: A1 .1 KEY PLAN 3/A2.1 NO SCALE v NOTE: PROVIDE BUILDING STANDARD CEILING TREATMENT AT ALL WINDOW LOCATIONS. AREA'400' REFLECTED CEILING PLAN 1/4' =1'-0' 1/A2.1 NORTH AREA '400' ELECTRICAL PLAN 1/4'= 1'4Y 2/A2.1 NORTH REFLECTED CEILING PLAN GENERAL NOTES NOT ALL MAY APPLY. REFER TO REFL. CEILING PLAN FOR ADDITIONAL NOTES AND CEILING INFORMATION. 1. REFER TO INDEX SHEET FOR TYPICAL WALL TYPES (WALLS TO DECK, RATED WALLS, ETC) AND ADDITIONAL WALL -TO -CEILING DESIGN CONDITIONS AND CONSIDERATIONS. 2. PROVIDE NIGHT LIGHT CIRCUITS AS REQUIRED. 3. REFER TO ROOM FINISH SCHEDULE FOR SPECIFIC CEILING TYPES, MATERIALS, ETC. 4. THE ARCHITECTURAL REFLECTED CEILING PLANS SHALL GOVERN THE LAYOUT OF ALL CEILING ELEMENTS AND/OR PENETRATIONS. COORDINATE WITH ARCHITECT ANY FIELD VERIFIED OR AS -BUILT CONDITIONS THAT DIFFER FROM WHAT IS SHOWN ON THESE PLANS. 5. SIZES OF MECHANICAL EQUIPMENT (IF SHOWN HERE) ARE SHOWN FOR REFERENCE ONLY. COORDINATE ACTUAL SIZES WITH MECHANICAL ENGINEER. 6. SIZES AND SHAPES OF LIGHTING AND OTHER MISC ELECTRICAL EQUIPMENT (IF SHOWN HERE) ARE SHOWN FOR REFERENCE ONLY. COORDINATE ACTUAL SIZES WITH ELECTRICAL ENGINEER. 7. UNLESS OTHERWISE NOTED INSTALL SUSPENDED CEILING GRID WITH EQUAL SIZE PANELS AT EACH SIDE OR ENDS OF ROOMS. NO PANELS SHOULD BE LESS THAN 1'-O" WIDE. 8. IF POSSIBLE ANY CEILING MOUNTED ITEMS (SPRINKLER HEADS, MOUNTING MECHANISMS, ETC) SHOULD BE CENTERED IN CEILING PANELS. 9. WHERE EXISTING CEILING GRID IS REMODELED TO MEET NEW CONSTRUCTION THE CONTRACTOR SHALL; A. REPLACE ALL DAMAGED OR UNREPAIRABLE PORTIONS OF EXISTING GRID WITH NEW GRID TO MATCH EXISTING BUILDING STANDARDS. B. REMOVE PORTIONS OF EXISTING GRID OR PROVIDE NEW GRID AS REQUIRED BY NEW CONSTRUCTION. ALL NEW GRID MUST MATCH EXISTING TO REMAIN OR BE BUILDING STANDARD. C. REPLACE ALL DAMAGED CEILING TILES WITH NEW TILES TO MATCH EXISTING TO REMAIN OR TO MATCH EXISTING BUILDING STANDARDS. 10. HVAC CONTRACTOR SHALL SUBMIT LAYOUT OF SUPPLY & RETURN DIFFUSERS TO ARCHITECT PRIOR TO INSTALLATION. REFLECTED CEILING LEGEND NOT ALL MAY APPLY. 2X4 FLUORESCENT 4 LAMP LIGHT FIXTURE WITH ACRYLIC LENS - HUBBELL R244BL277 2X2 FLUORESCENT LIGHT O : iXTURE WITH ACRYLIC LENS - HUBBELL RA4GNAO1F4E b6dNL FLUORESCENT LIGHT FIXTURE ON NIGHT LIGHT CIRCUIT (U.O.N.) INDICATES NEW CEILING GRID TO BE 'NSTALLED. INDICATES NEW GYPSUM BOARD BULKHEAD TO BE INSTALLED. $ WALL MOUNTED LIGHT SWITCH. COVER $3 PLATE COLOR TO MATCH EXISTING D ADJACENT COVER PLATES. ("3" DENOTES $ 3 -WAY SWITCH.) ("D" DENOTES DIMMER SWITCH.) ® COMBINATION LIGHT/EXHAUST FAN ®LED EXIT LIGHTS- HUBBELL PRB SOLID DENOTES DIRECTION OF FACEPLATE. RECESSED FLUORESCENT CAN LIGHTS- HUBBELL FMX13-277-62W NL INDICATES LIGHT FIXTURE TO BE ON A NIGHT LIGHT CIRCUIT. ALL ITEMS SHOWN ARE NEW. REFER TO ROOM FINISH SCHEDULE FOR SPECIFIC CEILING TYPES AND HEIGHTS. REFER TO FLOOR PLANS FOR SPECIFIC WALL CONSTRUCTION. NOTE: HVAC CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ADEQUATE HEATING, COOLING AND HUMIDITY CONTROL (AS APPLICABLE) IN ALL SPACES FORMED BY NEW CONSTRUCTION AS WELL AS ANY EXISTING SPACES RECONFIGURED BY NEW CONSTRUCTION. REFER TO MECHANICAL DRAWINGS FOR ALL LOCATIONS OF HVAC EQUIPMENT, EITHER SHOWN HERE OR NOT SHOWN HERE, AND COORDINATE WITH ARCHITECT OR ARCHITECT'S FIELD REPRESENTATIVE ANY CONFLICTS DISCOVERED BETWEEN ARCHITECT'S AND MECHANICAL ENGINEER'S DRAWINGS. NOTE: SPRINKLER CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ADEQUATE SPRINKLER LAYOUT IN ALL SPACES FORMED BY NEW CONSTRUCTION AS WELL AS ANY EXISTING SPACES RECONFIGURED BY NEW CONSTRUCTION. LAYOUT MUST MEET ALL APPLICABLE LOCAL AND STATE CODES. REFER TO SPRINKLER DRAWINGS FOR ALL LOCATIONS OF THAT EQUIPMENT, EITHER SHOWN OR NOT SHOWN HERE, AND COORDINATE WITH ARCHITECT OR ARCHITECT'S FIELD REPRESENTATIVE, AND MECHANICAL ENGINEER ANY CONFLICTS DISCOVERED BETWEEN SPRINKLER CONTRACTOR'S DRAWINGS AND ARCHITECT'S OR MECHANICAL ENGINEER'S DRAWINGS. NOTE; ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR THE REWIRING AND/OR RE -SWITCHING OF ALL LIGHT FIXTURES AND/OR LIGHT SWITCHES AS REQUIRED BY NEW CONSTRUCTION. COORDINATE WITH ARCHITECT ANY ADDITIONAL REQUIRED WORK NOT SHOWN HERE. ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENT OVER OTHER TRADES DRAWINGS WHEN CONFLICTS ARISE. GENERAL ELECTRICAL NOTES NOT ALL MAY APPLY. REFER TO ELECTRICAL PLAN FOR ADDITIONAL NOTES AND ELECTRICAL INFORMATION. 1. THIS DRAWING IS INTENDED TO PROVIDE INFORMATION RELATING TO THE LOCATION OF WIRING DEVICES AND OUTLETS ONLY. IT IS THE RESPONSIBILITY OF THE ELECTRICAL DESIGN/BUILD CONTRACTOR TO PROVIDE NECESSARY DOCUMENTS RELATING TO THE ACTUAL ELECTRICAL INSTALLATION AND TD INSTALL ALL WIRING DEVICES IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES. 2. ALL DIMENSIONS ARE FROM FINISHED WALL SURFACE OR COLUMN CENTERLINE TO CENTERLINE OF OUTLETS OR CENTERLINE OF PAIRS OF OUTLETS. 3. ALL W kLL MOUNTED WIRING DEVICES AND RECEPTACLES SHOWN BACK TO BACK SHALL BE OFFSET A MINIMUM OF 8' AND ACOUSTICALLY SEALED. 4. WHERE DIRECT CONNECTION TO PREWIRED FURNITURE PANELS OCCURS, PROVIDE POWER AND TELECOMMUNICATION FEEDS TO INDICATED PANEL LOCATION FROM WALL, COLUMN OR FLOOR SOURCE DIRECTLY ADJACENT TO THIS LOCATION. 5. ALL D(ISTING FLOOR MOUNTED ELECTRICAL/TELECOMMUNICATION LOCATIONS WHICH ARE NOT REUSED ARE TO BE REMOVED. REMOVE ALL ASSOCIATED CABLE, WIRE AND CONDUIT BACK TO SOURCE. PROPERLY PATCH AND REPAIR AFFECTED WALL, FLOOR AND/OR CEILING CONSTRUCTION. 6. UNLESS OTHERWISE NOTED ALL DEVICE ELEVATIONS REFER TO BOTTOM OF OUTLET BOX. 7. REFER TO REFLECTED CEILING PLANS FOR LOCATIONS OF LIGHT SWITCHES. 8. ALL OUTLETS THAT ARE IN THE VICINITY OF ANY WET AREAS (KITCHENS, BREAK ROOMS, RESTROOMS, JANITORIAL ROOMS WITH FLOOR SINKS, LAUNDRY ROOMS, STAND ALONE WALL MOUNTED SINKS, ELECTRIC WATER FOUNTAINS,ETC.) GROUND FAULT INTERRUPT (G.F.I.) TYPE. SEE ELECTRICAL LEGEND. ELECTRICAL LEGEND NOT ALL MAY APPLY. REFER TO ELECTRICAL PLAN FOR ADDITIONAL NOTES AND ELECTRICAL INFORMATION. 0 BUILDING STANDARD FLOOR MOUNTED SPECIAL MOUNTING HEIGHT INDICATION DUPLEX ELECTRICAL OUTLET. +420 FOR WALL OUTLETS. TAKEN TO Q BOTTOM OF PLATE. ® BUILDING STANDARD FLOOR MOUNTED Q DATA AND OR TELEPHONE LINE GFI INDICATES GROUND FAULT INTERRUPT OUTLET. L1J OUTLET. BUILDING STANDARD ELECTRICAL DIRECT CONNECTION LOCATION FOR POWER F_ AND COMMUNICATIONS FOR SYSTEMS � JUNCTION BOX. FURNITURE PANELS. =0 BUILCING STANDARD WALL MOUNTED C) CT) T U DUPLEX OUTLET. PP INDICATES POWER POLE LOCATION. 220 220 OUTLET p V SYSTEMS FURNITURE MOUNTED VOICE BUILDING STANDARD WALL MOUNTED FOUR-PLEX ELECTRICAL OUTLET. 4 D SYSTEMS FURNITURE MOUNTED BUILDING STANDARD WALL MOUNTED DATA OUTLET DEDICATED DUPLEX OUTLET. (1) THERMOSTAT b BUILDNG STANDARD WALL MOUNTED TELEPHONE AND OR DATA LINE OUTLET. ALL ITEMS SHOWN ARE NEW. -� BUILDING STANDARD T.V. CABLE OUTLET PLAN KEYNOTES O48 PAINTED PHONE BOARD. MOUNT BOTTOM 0 6" AFF CARSON DESIGN ASSOCIATES TEL 317.8435979 FAX 317.8435975 I I S90 N. MERIDIAN SUITE 104 CARMEL IND~ 46032 TEL 512.977.0520 FAX 512.977.0384 4201 W. PARMER LANE SUITE 104 AUSTIN TEXAS 78727 vm-W. ,. DAVID POWERS AItCHNTEC'f, P.C. 5816 CARROLLTON AVENUE INDWVAPOI.IS IN 46220 TEL 317.6275820 FAX 317.255.0468 amalk paw+arsar dVbn@aoLaom STAMP J W a v h W H a 0 ca y a oC a W Z a a a 0 z ISSUE: Preliminary Not For Construction 13 MAY 02 z W LU Q � Q p C') DC Uj L1J F_ F_ o � z T T C) CT) T U T 13 MAY 02 BID PRICING SET CDG SQUARE FOOTAGE: DRAWING TITLE: AREA '400' REFL, CLNG. & ELECTRICAL PLAN JOB NO. DATE: SHEET NUMBER: All PROVIDE GYPSUM BOARD BULKHEAD. --- - - - --- -- 8'-0" PROVIDE WHITE MELAMINE ON ALL 4" EQ. EQ. EQ. EQ. EQ. EQ. EQ. 4-1 EXPOSED SURFACES OF CABINET AND CABINET DOOR TO RECEIVE PLASTIC BACK SIDE OF CABINET DOOR- 1"x3/4" OOR.1"x3/4" APPLIED WOOD MUNTIN LAMINATE ON ALL EXPOSED SURFACES _ _ TYPICAL BOTH SIDES. A_ o LIEF7 C 3/4" MDF ADJUSTABLE WHITE MELAMINE � 6" 2'-0' SUSPENDED CEILING. -1 1 4- r �" SHELVES ON RECESSED SHELF HARDWARE TO BE WIRE PULLS. - `---- STANDARDS. TACKABLE SURFACE PLAN 11 1'-0" 6" 2,-0" � 3/4' SOLID WOOD. � A3.1 // I FELT PADS. PROVIDE NEOPRENE PADS ®BOTTOM. - HORIZONTAL SLIDING PASS-THRU 2,_0" 3/4' PARTICLE BOARD COVERED WITH PLASTIC LAMINATE. PROVIDE 4' HIGH _ 1/4" WHITE ACRYLIC DIVIDERS ®2" O.C. _ 1/4" CLEAR GLASS. co BACKSPLASH. "' PROVIDE A ROUTED CHANNEL FOR DIVIDERS 0 TO SLIDE IN ® TOP & BOTTOM. 1'x3/4" WOOD STOPPERS. PROVIDE WHITE MELAMINE ON ALL 10 EXPOSED SURFACES OF DRAWER. 1 HARDWARE TO BE WIRE PULLS. PROVIDE 1/2" x 3/4" WOOD TRIM LIP TO TO BE PAINTED WITH ACCENT PAINT. - COVER ROUTED CHANNELS. TYP. AROUND io BENJAMIN MOORE AMAZON GREEN CABINET DOOR TO RECEIVE PLASTIC 3/4' MDF ADJUSTABLE WHITE MELAMINE C ENTIRE OPENING ON BOTH SIDES. # 2136-30 LAMINATE ON ALL EXPOSED SURFACES _ SHELVES ON RECESSED SHELF HORIZONTAL SLIDING PASS-THRU ASSEMBLY. D1029A 'BARBARA MODEL' (C.R. LAURENCE 4" WOOD BASE PROVIDE WHITE MELAMINE ON ALL AROUND ENTIRE OPENING ON BOTH SIDES. OR EQUAL). EXPOSED SURFACES OF CABINET AND BACK SIDE OF CABINET DOOR. wALL BASE ELEVATION NOTE; STAIN ALL EXPOSED WOOD TO MATCH -- ADJACENT PASS-THRU WINDOW WOOD TRIM. 12 -°._ TE 1. EASE ALL EXPOSED EDGES. _ _ _ - - - _ - 2. S ME- A>� NOTE: ALL WOOD TRIM TO MATCH PLASTIC `r M �•1 1. PROVIDE WOOD BLOCKING AS REQUIRED. LAMINATE; NEVAMAR, CARMEL SAGAWOOD, WM-8-350T. 2. WOOD SPECIES TO BE Mt1'LE. PROVIDE 1/4' CHAMFER ALONG FRONT EDGE OF COUNTER TOP. 18" @ DEEPEST POINT, SOLID SURFACE ELEVATION 8/A3.1 TRANSACTION TOP. WALL BELOW TO SECTION NAM ELEVATION/ ENLARGED PLAN 1/A3■1 FOLLOW CURVE. _____________________ 1R=1'-0' `n 3. 00 L 2" 2'-0' AT CHECK-OUT 400 PROVIDE 12" DEEP SOLID SURFACE TRANSACTION TOP WITH BULLNOSE EDGE. CENTERED ON WALL. AT NURSE STATION 402 PROVIDE 12"D PLAS. LAM. 1'-0" TRANSACTION TOP WITH SELF EDGE. CENTERED ON WALL. -�_- -___- --_- ________ CABINET DOOR TO RECEIVE PLASTIC LAMINATE --------------------- -- _ --------------------------- 1"x3/4 APPLIED WOOD MULLION ON ALL EXPOSED SURFACES EXCEPT BACK - El 1 :1 El El [Sl SURFACE TO BE WHITE MELAMINE. REFER TO o TYPICAL BOTH SIDES. __ -____ _ _-____ - FINISH SCHEDULE. �I PROVIDE WHITE MELAMINE ON ALL INTERIOR GYPSUM BOARD, PROVIDE REQUIRED 11 I SURFACES OF CABINET. THICKNESS FOR CURVE. A3.1 � _-_-=_=-= _-------------------------- \X ____ ______ ____-___-___-___-_-= - ==- �X _ I - __ _____________________ N 00 TYPICAL WORK COUNTER. 10 j. TYPICAL COUNTER, REFER TO 3/A3.1. HARDWARE TO BE WIRE PULLS. WOOD BASE TO FOLLOW CURVE TACKABLE SURFACE TYPICALWORK COUNTER. 2' W WOODi'RIM PROVIDE PLASTIC LAMINATE ON ALL EXPOSED N SURFACES OF CABINET. N 4" VINYL BASE E77_777777__-___-_-_____=-==--=--=-=�= NOTE: PROVIDE WOOD BLOCKING AS REQUIRED. 3 5/8" METAL STUDS ® 16" O.C. W/ NOTE; 1. EASE ALL EXPOSED EDGES. 1'-6' 5/8' GYPSUM BOARD. 12 2. STAIN FRAME AND ALL W001 TRIM TO MATCH PLASTIC A3.1 LAMINATE; NEVAMAR, CARMEL SAGAWOOD, WM-8-350T. WOOD SPECIES TO BE MAPL. SECTION 12/A3■1 ELEVATION 9/A3■1 SECTION 5/A3■1 SECTION 2/A3■1 11/7 =1'-0' 1/2' =1' 0' 11/2' = Nr 11/2' =1'-0' 2'-0" 3/4' X 3" CONT. WOOD BLOCKING. 8'-3" 3/4" PARTICLE BOARD COVERED 2'-9" 3' 2'-6' WITH PLASTIC LAMINATE. CHAMFER CUSTOM UPPER CABINET. EDGE. ALIGN EDC OF UPPER CABINET ROUTE OUT UNDERSIDE OF TOP TO WITH EDGIOF CABINET BELOW. ��� /' `.\ LEAVE A 1/4" THICK SCRIBE. FIELD TRIM AS REQUIRED TO --------- ` ' ` ' WINDOW FRAME LINE = PROVIDE TIGHT FIT ALONG WALL TACKABLE SURFACE TO BE TAC WALL, ACORN 8'-0' COLOR, #C250-86 BY WALLTALKERS OR EQUAL. ' REFRIGERATOR I ,'\�`� ,'�`� ROUTE A GROVE IN WOOD TRIM TO HIDE EDGES 4' 6'-0' 4' 1'-0' 4' i BY TENANT I OF TACKABLE MATERIAL. I ' 3/4" X 3" CONT. WOOD BLOCKING. P.T.D. S.D. A3 1 PLASTIC LAMINATE COUNTERTOP 3/4" THICK WOOD TRIM. TYPICAL , I 2' X 2" WIRE CHASE CUTOUT AS REQUIRED. 1 I I I 1 1 1 1 I I I 1 I I I i I I rA WOOD BASE TO FOLLOW CURVE OF WALL I I L---------- 3/8'T CURVED GYPSUM BOARD. RADIUS 0 10'-4". e i I o I I o I DISHWASHER BY TENANT Cj I i LU I I L ---------J c C\, W Q C/)o 1'-3" 2' 3' 1 2' CUSTOM BASE CABINET. 1" X 4" SOLID OAK TOP PLATE. 10 CENTER ON VERTICAL SUPPORT LEG. TYPICAL AT EACH LEG. PLACE `14 BETWEEN FRONT & BACK BLOCKING. ANCHOR COUNTERTOP TO THIS PLATE. 3/4' PARTICLE BOARD SUPPORT LEG. FINISH TO MATCH COUNTERTOP ABOVE. COORDINATE WITH TENANT FOR 11'-4" SUPPORT & EQUIPMENT LAYOUT. 7'-4" NOTE; ' 1. PRVIDE A 1/4" COPPER WATER LINE FOR TENANT SUPPLIED COFFEE MAKER, REFRIGERATOR, 4 _ & ISHWASHER. COORDINATE WITH MANUFACTURER ON DRAIN REQUIREMENTS. DETAILS I O/A3■1 2. PRVIDE POWER AND SWITCH FOR GARBAGE DISPOSAL INSTALLED ON SINK. ® 24' DEEP UNIT ELEVATION 6/A3■1 TYP. WORK COUNTER SECTION 3/A3■1 1/2'= T -T 1112' = V4 PROVIDE GYPSUM BOARD BULKHEAD. GENERAL MILLWORK/CABINETRY NOTES ALIGN WITH WALL BEYOND. NOT ALL MAY APPLY. REFER TO PLANS, ELEVATIONS & SECTIONS FOR ADDITIONAL NOTES AND INFORMATION. 1. UNLESS OTHERWISE NOTED ON THIS DRAWING, REFER TO ROOM FINISH SCHEDULE (AND ROOM FINISH LEGEND) FOR ALL FINISH SELECTIONS. 2. UNLESS 01HERWISE NOTED ON THIS DRAWING, REFER TO ROOM FINISH SCHEDULE (AND ROOM FINISH 1" MDF ADJUSTABLE WHITE MELAMINE LEGEND) FOR ALL CABINET TYPES, MANUFACTURERS AND HARDWARE SELECTIONS. CABINET DOOR TO RECEIVE SHELVES ON RECESSED SHELF 3, WHERE FILLER STRIPS ARE REQUIRED BETWEEN CABINETS, CASEWORK ETC AND ADJACENT WALLS, PROVIDE PLASTIC LAMINATE ON ALL = = STANDARDS. MATCHING, EQUAL SIZE STRIPS AT EACH END. BY CABINET CONTRACTOR. EXPOSED SURFACES. 4. UNLESS OTHERWISE NOTED ON THIS DRAWING ALL COUNTERTOPS MUST BE CONTINUOUS. 3/4" 6'-0• 3/4' ALL COUNTERTOPS WITHOUT BACKSPLASHES MUST BE SCRIBED TO WALL AS NOTED ON SECTIONS AND DETAILS. 3/4' THICK WOOD TRIM. TYPICAL 5. CONTRACTOR SHALL BE RESPONSIBLE FOR THE FIELD VERIFICATION OF ALL DIMENSIONS, ROUGH OPENINGS 4" _ 4' 1'-O' 4' AND JOB CONDITIONS PRIOR TO BEGINNING FABRICATION OF ANY WORK SHOWN OR NOTED ON THIS DRAWING. CONTRACTOR MUST COORDINATE WITH CARSON DESIGN ASSOCIATES ANY DISCREPANCIES BETWEEN WHAT IS SHOWN 1 /4" OR NOTED ON THIS DRAWING AND ACTUAL FIELD VERIFIED CONDITIONS. HARDWARE TO BE WIRE PULLS. 6. UNLESS OTHERWISE NOTED, SINKS (WHERE INDICATED) WILL BE CENTERED WITHIN THE WIDTH OF CD THEIR CABINETS. SEE PLANS AND/OR ELEVATIONS FOR CABINET WIDTHS. t: Kl- 7. WHERE GARBAGE DISPOSALS ARE INDICATED PROVIDE A WALL MOUNTED SWITCH AS NEAR AS POSSIBLE TO 1'0/4" WOOD TRIM ON SIDES AND TOP. 8' FROM CENTERLINE OF SINK WITH BOTTOM OF SWITCHPLATE MIN OF 2" ABOVE TOP OF BACKSPLASH N TYPICAL BOTH SIDES. `- `-_ " PROVIDE WHITE MELAMINE ON ALL 8. PROVIDE 2' DIA. PLASTIC GROMMETS. LOCATE 4' FROM BACK WALL TO CENTER OF GROMMETS AND SPACE APPROX. EXPOSED SURFACES OF CABINET AND 3'-0" O.C. MAX. ON ALL WORK COUNTERS. PROVIDE SAMPLES IN ALL AVAILABLE COLORS FOR APPROVAL. PROVIDE TACKABLE SURFACE TO BE TAC WALL, ACORN BACK SIDE OF CABINET DOOR. GROMMET LOCATION LAYOUT TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 3/4" 3/4' COLOR, #C250-86 BY WALLTALKERS OR EQUAL. 9. PROVIDE A FAKE FRONT ON ALL BASE CABINETS WITH SINKS. ROUTE A GROVE IN WOOD TRIM TO HIDE EDGES OF TACKABLE MATERIAL 10. P.T.D.= PAPER TOWEL DISPENSER, BOBRICK MODEL 82621. LINE DENOTES WALL BELOW.S.D.= SOAP DISPENSER, BOBRICK MODEL 82112. SUPPIED BY TOILET PAPER/ SOAP VENDOR. ----- MOUNT SO THAT BOTTOM OF ITEMS ARE 4ABOVE TOP OF BACK SPLASH. SOLID SURFACE TRANSACTION TOP. K, 7'-4" RADIUS 0 10'-6". NOTE: 1. PROVIDE WOOD BLOCKING AS REQUIRED. 2. PROVIDE CABINET LOCKS ON ALL CABINETS d IN NURSE STATION 402. DETAILS A 11 3■1 -°" / SECTION 7/A3■1 LIJ GIBBON DESIGN ASSOCIATES TEL 317.8435979 FAX 317.843.5975 11590 N. MERIDIAN k Il bio. CARMEL INDIANA 46032 TEL 512977.0520 FAX 512.977.0384 4201 W. PARMER LANE SUIT E 104 AUSTIN TEXAS 78727 DAVID POWERS ARCHITECT, P.C. 5816 CARROLLTON AVENUE INDWVAPOLIS IN 46220 TEL 317.627.5820 FAX 317.255.0468 wnWk p---- sarchaom STAMP Preliminary Not For Construction 13 MAY 02 ISSUE: 13 MAY 02 BID PRICING SET CDG SQUARE FOOTAGE: DRAWING TITLE: DETAILS & ELEVATIONS JOB NO. DATE: 0200082 SHEET NUMBER: A3.1 W Cj LU y c C\, W Q C/)o � J Q Q Q Q U Q C= Q m 75 w 0 z yz o a � ZD z O 4 T W ISSUE: 13 MAY 02 BID PRICING SET CDG SQUARE FOOTAGE: DRAWING TITLE: DETAILS & ELEVATIONS JOB NO. DATE: 0200082 SHEET NUMBER: A3.1 AREA '400' FINISH PLAN 1/4'= l' -O' ROOM FINISH LEGEND 1/A4.1 [iC•I�1L CODE DESCRIPTION MANUFACTURER COLOR NUMBER PATTERN / MODEL REMARKS CPT -1 CARPET SHAW CONTRACT MAKE YOUR MARK 50462-62500 VENTURE CAPITAL --- VCT-1 VINYL COMPOSITION TILE MANNINGTON SANDRIFT LU 137 y-� ESSENTIALS 12"x12" TILE VCT -2 Q VINYL COMPOSITION TILE MANNINGTON OYSTER WHITE 131 a ESSENTIALS o 12"x12" TILE VCT -3 U VINYL COMPOSITION TILE MANNINGTON MINERAL GRAY � LU 175 0 ESSENTIALS 12"x12" TILE 8-1 VINYL WALL BASE J JOHNSONITE z PEARL 22 --- 4" COVE BASE WC -1 VINYL WALLCOVERING 'I.. JM LYNNE T SAVANNAH KYL-8848-69 KYLIN TYPE 1, 54" WIDE ORDER WITH QUOTE NUMBER 518904 WC -2 T VINYL WALLCOVERING W SYMPHONY (DL COUCH) --- SSP40 SYMPHONY SELECT PROGRAM TYPE 2, 54" WIDE WC -3 VINYL WALLCOVERING LEN—TEX MDC WALLCOVERING ( � ARMORY 4812—CS CASSIA TYPE 2, 54" WIDE ORDER WITH QUOTE NUMBER 40094697 WC -4 VINYL WALLCOVERING LEN—TEX (MDC WALLCOVERING) ASHLER 4808—CS CASSIA TYPE 2, 54" WIDE ORDER WITH QUOTE NUMBER 40094697 WC -5 VINYL WALLCOVERING JM LYNNE HASAKI ERL-4115-69 ERLANO TYPE 2, 54" WIDE PL -1 PLASTIC LAMINATE FORMICA STRINGMET 7705-58 --- MATTE FINISH PL -2 PLASTIC LAMINATE FORMICA PUMICE 858-58 --- MATTE FINISH PL -3 PLASTIC LAMINATE WILSONART BRUNE SLATE 1763-60 --- PL-4 PLASTIC LAMINATE FORMICA EARTH WASH 7213-58 --- MATTE FINISH SS -1 SOLID SURFACE CORIAN SILT (C) --- --- --- CL-1 ACOUSTICAL CEILING TILE USG WHITE 76575 ECLIPSE CLIMA PLUS 2'x2'x3/4" TILE. USE WITH THE USG DONN DX GRID SUSPENSION SYSTEM. ROOM FINISH SCHEDULE ROOM FLOOR CABINETS / MILLWORK WALLS CEILING NO. NAME FLOOR BASE CABS. COUNTER TOP NORTH EAST SOUTH WEST MATERIAL HEIGHT REMARKS 400 CHECK—OUT CPT -1 B-1 -- * WC -1 WC -1 WC -1 WC -1 CL -1 +8'-6" *TRANSACTION TOP TO BE SS -1. 401 BUSINESS OFFICE CPT -1 B-1 * PL -3 WC -1 WC -1 WC -1 WC -1 CL -1 +8'-6" *CHART PASSTHRU ON EAST WALL TO BE PL -2. 402 NURSE CPT -1 B-1 PL -2 �'PL-3 WC -1 WC -1 WC -1 WC -1 CL -1 +8'-6" *TRANSACTION TOPS TO BE PL -4. 403 HALL CPT -1 B-1 -- -- WC -1 WC -1 WC -1 WC -1 CL -1 +8'-6" -- 404 TREADMILL/ECHO CPT -1 B-1 -- -- WC -2 WC -2 WC -2 WC -2 CL -1 +8'-6" -- 405 HALL CPT -1 B-1 -- -- WC -1 WC -1 WC -1 WC -1 CL -1 +8'-6" -- 406 EXAM 6 CPT -1 B-1 PL -2 PL -3 WC -4 WC -4 WC -4 WC -4 CL -1 +8'-6" -- 407 EXAM 5 CPT -1 B-1 PL -2 PL -3 WC -3 WC -3 WC -3 WC -3 CL -1 +8'-6" -- 408 HALL CPT -1 B-1 -- -- WC -1 WC -1 WC -1 WC -1 CL -1 +8'-6" -- 409 M.D. OFFICE CPT -1 B-1 -- -- WC -5 WC -5 WC -5 WC -5 CL -1 +8'-6" -- 410 BREAK ROOM *VCT— 1,2,3 B-1 PL -2 PL -1 WC -2 WC -2 WC -2 WC -2 CL -1 +8'-6" *SEE FINISH PLAN 1/A4.1. 411 R.R. *VCT— 1,2,3 B-1 -- -- WC -2 WC -2 WC -2 WC -2 CL -1 +8'-6" *SEE FINISH PLAN 1/A4.1. 412 EXAM 4 CPT -1 B-1 PL -2 PL -3 WC -4 WC -4 WC -4 WC -4 CL -1 +8'-6- 413 EXAM 3 CPT -1 B-1 PL -2 PL -3 WC -3 WC -3 WC -3 WC -3 CL -1 +8'-6" -- 414 EXAM 2 CPT -1 B-1 PL -2 PL -3 WC -4 WC -4 WC -4 WC -4 CL -1 +8'-6" -- 415 EXAM 1 CPT -1 B-1 PL -2 PL -3 WC -3 WC -3 WC -3 WC -3 CL -1 +8'-6" -- 416 TEL. CLOSET CPT -1 B-1 -- -- WC -1 WC -1 WC -1 WC -1 CL -1 +8'-6" -- GENERAL FINISH PLAN NOTES NOT ALL MAY APPLY. REFER TO PLANS FOR ADDITIONAL NOTES AND INFORMATION. 1. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS, JOB CONDITIONS, ETC. 2. ALL DIMENSIONS ON PLANS ARE TO FACE OF FINISHED WALL. 3. WHERE DISSIMILAR FLOOR MATERIALS MEET THEY SHALL DO SO UNDER THE CENTERLINE OF THE DOOR, UNLESS NOTED OTHERWISE. 4. ALL FINISHES SHALL CONFORM TO CHAPTER 42 OF THE INDIANA BUILDING CODE. 5. ALL VCT GRAPHIC LINES TO BE AT A 450 ANGLE AND THE VCT TILE TO BE INSTALLED AT A 45° ANGLE. 6. USE JOHNSONITE TRANSITION STRIP WHERE CARPET AND VCT MEET IN COLOR #22 PEARL. 7. USE DOUG MOCKS T & COMPANY DRAWER PULLS STYLE DP -36 IN SATIN STAINLESS STEEL FOR ALL CABINETRY WHERE PULLS ARE REQUIRED. VCT GRAPHIC LEGEND REFER TO ROOM FINISH LEGEND FOR EXACT SPECIFICATIONS. KEY PLAN 2/A1.1 mm CARSON DESIGN ASSOCIATES TEL 317.8435979 FAX 317.8435975 11590 N. MERIDIAN SUITE 104 CARMEL INDIANA 46032 TEL 512.977.0520 FAX 512.977.0364 4201 W. PARMER LANE SUITE 104 AUSTIN TEXAS 78727 wwwA2raondesVLcom DAVID POWERS ARCMECT, P.C. 5816 CARROLLTON AVENUE INDIANAPOLIS IN 46220 TEL 317.6275820 FAX 317.255.0468 STAMP Preliminary Not For Construction 13 MAY 02 mi W a w o LU y-� CV W Q C/)o co a Q o Q U Q � LU 0 LU � z Ca J Ca z oUj 'I.. T U CD rn U T W Cm ISSUE: 13 MAY 02 BID PRICING SET CDG SQUARE FOOTAGE: DRAWING TITLE: AREA'400'FINISH PLANAEGEND & SCHEDULE JOB NO. DATE: SHEET NUMBER: A4.1