GENERAL DATA
1. ALL CONSTRUCTION MATERIALS AND WORK MUST COMPLY WITH CODE REQUIREMENTS OF
THE INDIANA ADMINISTRATIVE BUILDING COUNCIL, THE STATE BOARD OF HEALTH, THE
STATE FIRE MARSHALL, AND THE LOCAL GOVERNING AUTHORITY AS SET BY, BUT NOT
LIMITED TO THE FOLLOWING:
• 2014 INDIANA BUILDING CODE (IBC) (2012 INTERNATIONAL BUILDING CODE W/
INDIANA AMENDMENTS)
• 2010 INDIANA ENERGY CONSERVATION CODE (IECC) (ASHRAE 90.1-2007 W/ INDIANA
AMENDMENTS)
• 2014 INDIANA FIRE CODE (IFC) (2012 INTERNATIONAL FIRE CODE W/ INDIANA
AMENDMENTS)
• 2014 INDIANA MECHANICAL CODE (IMC) (2012 INTERNATIONAL MECHANICAL CODE W/
INDIANA AMENDMENTS)
• 2012 INDIANA PLUMBING CODE (IPC) (2006 INTERNATIONAL PLUMBING CODE W/
INDIANA AMENDMENTS)
• 2009 INDIANA ELECTRICAL CODE (IEC) (2008 NATIONAL ELECTRICAL CODE W/
INDIANA AMENDMENTS)
• 2014 INDIANA FUEL GAS CODE (IFGC) (2012 INTERNATIONAL FUEL GAS CODE W/
INDIANA AMENDMENTS)
• ALL CURRENT LOCAL CODES, ORDINANCES, AND REGULATIONS.
1. THE OWNER WILL OBTAIN APPROVAL FROM THE APPLICABLE AGENCIES REFERENCED
ABOVE PRIOR TO BEGINNING CONSTRUCTION.
2. DO NOT SCALE DRAWINGS; USE ONLY WRITTEN DIMENSIONS. IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ALL DIMENSIONS OF THE PROPOSED
STRUCTURE ARE CORRECT BEFORE WORK BEGINS.
3. INTERIOR FINISHES SHALL BE IN ACCORDANCE WITH CHAPTER 8 OF THE IBC AND ANY
OTHER APPLICABLE PART OF THE IBC.
4. ALL WOOD AND METAL STUD WALLS SHALL HAVE STUDS SPACED AT 16" ON CENTER
UNLESS NOTED OTHERWISE. SEE STRUCTURAL FOR LUMBER GRADE AND/OR METAL
GAUGE REQUIREMENTS. SEE WALL KEYS FOR WALL MATERIALS.
5. ALL DIMENSIONS ARE ROUGH FRAMING DIMENSIONS (OUTSIDE FACE OF STUD TO
OUTSIDE FACE OF STUD OR OUTSIDE FACE OF MASONRY TO OUTSIDE FACE OF
MASONRY).
6. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO INFORM KJG ARCHITECTURE, INC.
OF ANY UNSAFE CONDITION OR CODE VIOLATION, EITHER STATE OR LOCAL, PRIOR TO
THE START OF CONSTRUCTION.
7. THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL WORK WITH ALL TRADES
(PLUMBING, ELECTRICAL, MECHANICAL AND OTHERS) TO ENSURE THAT ALL REQUIRED
CLEARANCES ARE MADE PRIOR TO PROCEEDING WITH THE PROJECT, AND SHALL NOTIFY
THE ARCHITECT OF ANY CONFLICTS PRIOR TO THE START OF CONSTRUCTION.
8. IF FIELD CONDITIONS EXIST THAT REQUIRE ALTERATIONS TO THESE PLANS, KJG
ARCHITECTURE, INC. MUST BE NOTIFIED AT ONCE AND BEFORE ANY FURTHER
CONSTRUCTION TAKES PLACE.
9. PROVIDE SOLID BLOCKING FOR ALL WALL -MOUNTED ITEMS SUCH AS (BUT NOT LIMITED
TO) HANDRAILS, CABINETS, TOWEL BARS, GRAB BARS, TOILET ACCESSORIES AND
SHELVING.
10. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE APPROVED
PRESSURE -TREATED MATERIAL.
INTERIOR FINISHES
1. INTERIOR FINISH RATINGS SHALL COMPLY WITH CHAPTER 8 AND TABLE 803.9 OF THE
2014 IBC.
GYPSUM WALLBOARD
1. ALL NON -RATED WALL CONSTRUCTION SHALL HAVE 5/8" REGULAR GYPSUM WALLBOARD.
2. PROVIDE MOISTURE -RESISTANT GYPSUM WALLBOARD (GREEN BOARD) AT ALL PLUMBING
WALLS. AT WALLS REQUIRED TO BE FIRE -RATED, INSTALL (1) LAYER OF 5/8"
MOISTURE -RESISTANT GYPSUM BOARD OVER THE TOP OF ALL REQUIRED TYPE 'X'
GYPSUM BOARD.
FLOOR COVERINGS
1. INTERIOR FLOOR FINISHES AND FLOOR COVERING MATERIALS WHICH ARE TO BE OF
CLASS I OR II MATERIALS SHALL BE CLASSIFIED IN ACCORDANCE WITH NFPA 253.
2. INTERIOR FLOOR FINISH AND FLOOR COVERING MATERIALS SHALL BE TESTED BY AN
APPROVED AGENCY IN ACCORDANCE WITH NFPA 253 AND SHALL BE IDENTIFIED BY A
HANG TAG OR OTHER SUITABLE METHOD SO AS TO IDENTIFY THE MANUFACTURER OR
SUPPLIER AND STYLE, AND SHALL INDICATE THE INTERIOR FLOOR FINISH OR FLOOR
COVERING CLASSIFICATION.
3. SEE FINISH SCHEDULE FOR FLOOR FINISHES.
PAINTING
1. ALL PAINTED INTERIOR FINISHES SHALL CONSIST OF A MINIMUM OF ONE COAT PRIMER
AND TWO COATS LATEX PAINT. UNLESS NOTED OR SCHEDULED OTHERWISE, KITCHENS,
BATHROOMS AND LAUNDRIES SHALL RECEIVE SEMI -GLOSS FINISH. COMMERCIAL KITCHENS
SHALL RECEIVE GLOSS FINISH.
W
Z � Q
(If Z
Q
F LU Q
F V cfl Z
w
LLB J
0 w
w fir-
U
ti
DISCLAIMER:
This is an original design, created by KJG Architecture, Inc. The
concepts, ideas, plans and details are the sole property of KJG
Architecture, Inc. None of the aforementioned shall be used by or
disclosed to any person, firm or organization for any purpose
without the prior written permission of KJG Architecture, Inc.
PROFESSIONAL SEAL:
PROJECT DATE:
09/14/2018
No. DESCRIPTION: DRAWN DATE
BY: ISSUED:
PROJECT NUMBER: DRAWN BY:
A2018.078 MSM
DRAWING TITLE:
FLOOR PLAN
SHEET NUMBER:
Al 05
vvuudni nunu