Loading...
HomeMy WebLinkAboutA300O123'-11 9/1 f "F TOP OF TRUSS 112' - 0" `� TRUSS BEARING OL 109' - 0" "F HEAD HEIGHT 100' - 0" `� MAIN LEVEL BUILDING SECTION SCALE: 1 /4"=1 '-0" 1�23'-11 `F TOP OF 1�12'-0' `� TRUSS 1�00'-0' `r MAIN LE 9�8'-0" `r ICE RINI 5 A305 SLOPE MIN. 1 /4" PER FT. / SLOPE MIN. 1/4" PER FT. r,, 5 A305 *a�/ \ *40--.050 / 2 BUILDING SECTION A300 SCALE:1/4"=1'-0" RELEASED FOR CONSTRUCTION Subjeut to compliance with alll redulh46uns of State and local Eod�s 5 12 A305 0 1 12 0 1 5 A305 SECTION KEYNOTES: 1. CONCRETE FOOTING/FOUNDATION, REFER TO FOUNDATION PLAN, DETAILS & SECTIONS. 2. REINFORCED CONCRETE SLAB, REFER TO FOUNDATION PLAN & DETAILS. 3. 2" RIGID INSULATION. 4. UNDISTURBED OR WELL COMPACTED SOIL. 5. 4" MIN. GRANULAR FILL OVER 10 MIL. VISQUEEN VAPOR BARRIER. 6. 6" OF 3/4" CRUSHED STONE 7. 3" OF LIMESTONE SCREENING BY "CUSTOM ICE, INC." 8. 5/8" UNDER FLOOR HEATING TUBES BY "CUSTOM ICE, INC." 9. VAPOR BARRIER OVER (2) LAYERS OF 1 1 /2" INSULATION BY "CUSTOM ICE, INC." 10. 2" STEEL CHAIR SUPPORTS SPACED ® 24" O.C. BY "CUSTOM ICE, INC." 11. 4x4x4/4 WWM REINFORCING STEEL GRID #2 BY "CUSTOM ICE, INC." 12. 5/8" PRE-FAB POLYETHYLENE PIPING SPACED ® 1 1 /2" O.C. BY "CUSTOM ICE, INC." 114'-0" 13. 4x4x4/4 WWM REINFORCING STEEL GRID #1 BY "CUSTOM ICE, INC." LOW EAVE HEIGHT 14. 5" CONCRETE PAD BY "CUSTOM ICE, INC." 15. 1" EXPANSION MATERIAL W/SELF LEVELING EXPANSION JOINT SEALANT. 16. PERIMETER SLAB POURED CONTINUOUS W/RINK SLAB BY "CUSTOM ICE, INC. 17. 5/8" BOARD ANCHOR W/2" CONCRETE ANCHOR BY "CUSTOM ICE, INC." 18. 5%42" RINK BOARD SYSTEM BY "CUSTOM ICE, INC." 19. 48" GLASS PANEL ASSEMBLY BY "CUSTOM ICE, INC." 20. PERIMETER NETTING FROM TOP OF GLASS ASSEMBLY TO UNDERSIDE OF CEILING BY "CUSTOM ICE, INC." 21. PLAYERS BENCH BY "CUSTOM ICE, INC." 22. GLULAM COLUMN AND BEAM BY "GLU-LAM ERECTORS, INC." REFER TO STRUCTURAL PLANS AND DETAILS. 23. ANCHOR PLATE, REFER TO STRUCTURAL PLANS AND DETAILS. 24. 2x6 P.T. BASE PLATE OVER SILL SEALER W/A.B., REFER TO STRUCTURAL VARIES PLANS AND DETAILS. FIN. GRADE 25. 2x6 STUD WALL, REFER TO STRUCTURAL. 98' 0" � 26. 7/16" "ZIP SYSTEM" WALL SHEATHING INSTALLED PER MANUFACTURERS ICE RINK RECOMMENDATIONS. 27. EXTERIOR FINISH PANEL & BATTEN BOARDS TO MATCH EXISTING ADJACENT BUILDING. STAIN TO MATCH ADJACENT WALLS. 28. CLOSED CELL SPRAY INSULATION. 29. 10 MIL. VISQUEEN VAPOR BARRIER OVER 2" RIGID INSULATION. 30. 5/8" GYPSUM BOARD 31. GLULAM PURLINS BY "GLU-LAM ERECTOR, INC.", REFER TO STRUCTURAL PLANS & DETAILS. 32. 2" ROOF DECKING BY "GLU-LAM ERECTOR, INC." 33. 10 MIL. VAPOR BARRIER OVER 7/16" OSB SHEATHING. 34. 4" POLYISO INSULATION W/ 7/16" COVER BOARD. 35. 60 MIL. EPDM MEMBRANE FULLY ADHERED SYSTEM INSTALLED PER MANUFACTURES RECOMMENDATIONS. 36. 2x BLOCKING AS REQ'D. 37. EPDM ROOF EDGE PER MANUFACTURES RECOMMENDATIONS. 38. CONTINUOUS METAL ROOF EDGE. 39. METAL GUTTER. TYPE & DESIGN TO MATCH EXISTING GUTTER AT ADJACENT BUILDING. 40. 2x8 ALUM. CLAD FASCIA BOARD 41. 1x6 TRIM BOARD 42. DOUBLE TOP PLATE TO MATCH WALL WIDTH 43. 4 TIER BLEACHER FOR ICE RINK BY "BLEACHER INTERNATIONAL", 1550 W. EVANS AVE., UNIT A, DENVER, CO 80223, PHONE 303-646-1038, WEB WWW.GETSEATING.COM, OR APPROVED EQUAL. 44. INSULATED ROLLING DOOR ASSEMBLY BY "CORNELL COOKSON", 24 ELMWOOC AVE., MOUNTAIN TOP, PA 18707, PHONE 800-233-8366, WEB WWW.CORNELL000KSON.COM, OR APPROVED EQUAL. 45. DOOR/WINDOW ASSEMBLY, REFER TO DOOR/WINDOW SCHEDULE FOR TYPE & 114'-00"" SIZE. EAVE HEIGHT 46. CAULK ALL AROUND BOTH SIDES OF ASSEMBLY 47. BEAM/HEADER, PROVIDE BEAM OR HEADER PER SCHEDULE ON STRUCTURAL FRAMING PLANS. 48. R-38 BATT INSULATION MIN. 49. PRE-ENGINEERED ROOF TRUSS ® 24" O.C. 50. EPDM MEMBRANE EXPANSION JOINT PER MANUFACTURES RECOMMENDATION. 51. 7/16" OSB SHEATHING. 52. WINDOW SILL, REFER TO FINISH SCHEDULE 53. CABINET AND COUNTERTOP, REFER TO FINISH SCHEDULE FOR STYLE & COLORS. 54. R-21 (5 1 /2") BATT INSULATION 55. SOFFIT PANEL TO MATCH EXIST. ON ADJACENT BUILDING. 56. 3" WIDE SOFFIT VENT WITH INSECT SCREEN 57. INSULATION STOP 58. ICE & WATER SHIELD SELF -ADHERED ROOFING MEMBRANE UNDERLAYMENT OVER 7/16" OSB SHEATHING. 59. SLATE SHINGLES TO MATCH EXIST. SLATE ON ADJACENT BLDG. INSTALL PER 98'_00"" MANUF. RECOMMENDATIONS. ICE RINK LEVEL 60. SNOW/ICE GUARD TO MATCH EXIST. SNOW/ICE GUARDS ON ADJACENT BLDG. INSTALL PER MANUF. RECOMMENDATIONS. 61. MORTAR SETTING BED OVER MORTAR SCRATCH COAT OVER METAL LATHE 62. METAL FLASHING 63. CULTURED STONE, STYLE & COLOR TO MATCH EXISTING CULTURED STONE ON ADJACENT BLDG. 64. WEEP SCREED. MAINTAIN CLEARANCE FROM GRADE OR FIN. CONC. AS RECOMMENDED BY CULTURED STONE MANUF. 65. EXIST. CONC. SLAB TO REMAIN AS SHOWN. CUT & REMOVE AS REQ'D. FOR NEW BLDG. CONSTRUCTION. 66. NEW BRACKET. USE EXIST. BRACKET AS TEMPLATE FOR CONSTRUCTION OF NEW BRACKET. 67. ROOF EXTENSION TO MATCH EXIST. CONDITION ON ADJACENT BLDG. LJJ Z � Q (If Z a LU 2 p V Z F Cfl - �' W J W w a. LU fir- U ti DISCLAIMER: This is an original design, created by KJG Architecture, Inc. The concepts, ideas, plans and details are the sole property of KJG Architecture, Inc. None of the aforementioned shall be used by or disclosed to any person, firm or organization for any purpose without the prior written permission of KJG Architecture, Inc. PROFESSIONAL SEAL: PROJECT DATE: 09/14/2018 No. DESCRIPTION: DRAWN DATE BY: ISSUED: PROJECT NUMBER: DRAWN BY: A2018.078 MSM DRAWING TITLE: BUILDING SECTIONS SHEET NUMBER: A300 DATE: 11/26/18 William Hohlt