HomeMy WebLinkAboutM501NOTES: TRAP SUCTION LINE PER MANUFACTURER RECOMMENDATION. HARD START KIT INSTALLED ON OUTDOOR UNIT. ON GRADE SUCTION LINE LIQUID AND SUCTION REFRIGERANT LINES (INSULATE LINES) DUCTLESS SPLIT OUTDOOR (DSO) LIQUID LINE SIGHT GLASS REFRIGERANT PIPING DIAGRAM NO SCALE 3/8"x2-1/2" ANCHOR BOLT (4 MIN READ) EQUIPMENT MOUNTING TAB OR 1/8"x2x3x3" LONG BENT ANGLE GRADE CONDENSING UNIT FILTER DRIER PROVIDE 5/16" WAFFLE PAD UNDER MOUNTING FEET CONDENSING UNIT MOUNTING DETAIL NO SCALE NOTES: UNITS SHALL BE INTERNALLY ISOLATED AND BOLTED TO CURB. OSALOUVER 0-100% ECONOMIZER EXHAUST LOUVER EQUIPMENT CURB MUST BE LEVEL & DIMENSIONALLY COMPATIBLE WITH UNIT DUCTLESS SPLIT INDOOR (DSI) 20' DIFFERENCE IN HEIGHT OR >80' IN TOTAL EQUIVALENT LENGTH = LONG -LINE APPLICATION TYP 4" CONCRETE EQUIPMENT PAD 6" LARGER THAN UNIT ALL AROUND EXPAND AS NEEDED FOR MULTIPLE UNITS. PROVIDE MANUFACTURER"S RECOMMENDED CLEARANCES BETWEEN UNITS. TYP FILTER SECTION COIL & BLOWER SECTION DISCHARGE SECTION CONDENSING SECTION HOUSEKEEPING PAD ON GRADE PACKAGED AIR CONDITIONER DETAIL"ADD ALTERNATE" SCALE: NONE RELEASED FOR CONSTRUCTION Subjeutto can pfi@ ce with alll redullatiuns of State and local Codes City of camel DATE: 11/26/18 William Hohlt NOTES: 1. ALL BRANCH TAKE -OFFS TO BE INSTALLED PER SMACNA DUCT CONSTRUCTION STANDARDS. 2. ALL MANUAL BALANCING DAMPERS ON SUPPLY AIR DUCT SERVING VAV BOXES TO BE LOCKED IN OPEN POSITION WITH SCREW THROUGH HANDLE. DUCT TAKE -OFFS NO SCALE EXHAUST FAN HOUSING BLOCKING, BOTH SIDES - OF FAN AS REQUIRED CEILING JOIST GYPSUM BOARD CEILING EXHAUST GRILLE 1 I ifI EXHAUST DUCT NOTES: FLEXIBLE CONNECTION SHALL HAVE A FLAME SPREAD INDEX OF 75 OR LESS AND A SMOKE -DEVELOPED RATING OF 150. CEILING MOUNTED EXHAUST FAN NO SCALE FLEXIBLE DUCT (TYP) (MAXIMUM LENGTH 6') CLAMP (TYP) MANUAL BALANCING DAMPER WITH LOCKING QUADRANT ROUND DUCT TAKE -OFF TO MATCH FLEXIBLE DUCT ROUND DUCT 3RANCH DUCT MANUAL BALANCING DAMPER KITH LOCKING QUADRANT SPIN -IN DUCT TAKE -OFF WITH EXTRACTOR RECTANGULAR OR ROUND DUCT MANUAL BALANCING DAMPER WITH LOCKING QUADRANT RECTANGULAR DUCT INSTALL PER MANUFACTURER'S INSTRUCTION TYP FLEXIBLE CONNECTION EXHAUST DUCT TYP SHEET METAL SCREW - (4 PER COLLAR MIN) COLLAR FACTORY INSTALLED CLAMP FLEXIBLE DUCT (MAX LENGTH 6') II I I 0 CEILING SURFACE MOUNTED NOTE: FLEXIBLE DUCT MUST BE SEALED TO COLLAR. COLLAR FACTORY - INSTALLED SPIN -IN FITTING DISTRIBUTION BOX 24 GAGE MINIMUM ----- OR ----- FLEXIBLE DUCT (MAXIMUM LENGTH 6') CLAMP SHEET METAL SCREW (4 PER COLLAR MIN) TURN UP 1" MINIMUM CEILING SURFACE MOUNTED NOTES: FLEXIBLE DUCT MUST BE SEALED TO COLLAR. AIR DISTRIBUTION CONNECTION NO SCALE NOTES: FAN & PRE-FAB CURB SHALL SIT LEVEL. PROVIDE LEVEL BASE IF ROOF IS PITCHED. EXHAUST FAN PRE-FAB CURB WITH CANT RIGID INSULATI SUPPORT ELBOW FROM STRUCTURE W/SHEET METAL STRAP WRAPPED AROUND DUCT AS INDICATED EXTERNAL INSULATE UP TO BACK OF DIFFUSER, REGISTER OR GRILLE (NOT READ FOR EXHAUST DUCTS) HARD CONNECTION CEILING INLAY DIFFUSER, REGISTER OR GRILLE SUPPORT BOX FROM STRUCTURE W/ (2) SHEET METAL STRAPS EXTERNAL INSULATE ENTIRE BOX UP TO BACK OF DIFFUSER, REGISTER OR GRILLE (NOT READ FOR EXHAUST DUCTS) CEILING INLAY DIFFUSER, REGISTER OR GRILLE ROOFING ROOF BACKDRAFT DAMPER EXHAUST DUCT ROOF MOUNTED EXHAUST FAN INSTALLATION DETAIL NO SCALE TYP TYP W Z Uj Q Z Q � W � z �U C-0_ v LU � J U) a Q � W 0� > U � ti DISCLAIMER: This is an original design, created by KJG Architecture, Inc. The concepts, ideas, plans and details are the sole property of KJG Architecture, Inc. None of the aforementioned shall be used by or disclosed to any person, firm or organization for any purpose without the prior written permission of KJG Architecture, Inc. PROFESSIONAL SEAL: Q ,OFESS/O D. NO. PE10910442 z m m s�gTF O PROJECT DATE: 09/ 14/2018 No. DESCRIPTION: DRAWN BY: DATE ISSUED: PROJECT NUMBER: DRAWN BY: DRAWING TITLE: MECHANICAL DETAILS SHEET NUMBER: