Loading...
HomeMy WebLinkAboutS100a CV CV I CqCV CD M I PO CD POI rM LO CD I CV RELEASED FOR CONSTRUCTION Subjeut to compliance with alll iegulhtiuns of State and local Codes 8 S300 Ip�l� lall _ 8 6 $ S300 S305 2 S105 I I I I I I I SIM. 7 I 1 4 k s3oo S300 S305 S305 I 16 05 98.0 J'2 B.F.F.) L J L — LOWE i s3oo _ 1 i - - - - _ _ I � I II II I I 1 1 I I I I I 11 j S300 I 1 1 1 1 I I s3oo I L I I I I I I 1 P-1— L —P-1 I 18'-2 1/2" U_ 8 S300 I r -- — —-- IU_ I I I I I I $ I I I I II I � S305 LP 1— F— � I 100.00' (0' 0" A.F.F.) MAIN LEVEL F.F. CJ r I I II 3 Now I l CJ 1 I ILP\1-� I F- � I CJ — 5 — I I 7 I r CJ 6 1 S300 1 I I I 'I I 1 CJ LP-1-� CJ 1 0 � I r L L_ — CJ 4 � 1 I I III 1 1 I I I I I I I I 1 1PC7J\ 1 I I 1 8 1 II 1 S300 NI LI I I I I S305 \ I- 1 I CJ - - - -- - - - --- - - - - - I 7 1 P- I I I I 1 L- S300 I —1 J L I � � � I I I I I I I SIM. I I s 3 to TYP 1 1 5 NS305,r-) 4 S305 2 S30 5 S305 I I � I I 1 5 1 s305 1 I 98.00' (2r Orr B.F.F.) — LP-1— L —P-1 J I 1 I (T LOWER L EL o lo`F—\ /F-1 — — — — — — — — — — — — — — —-—---- — —�— �- 1 I 8 L--� L I I s3oo I I I I I I I 1 1 I I 1 I I I � 3 1 II I I I I II 1 S300 P-1 I 1 LP-1 7 F_1J -- F-3 1----- — F— P-2 F-2 P-2 F-2 �7 P-2 P-2 F-2 — 1 1 r4 — — — ----- — — — ----- — — — -----_�-2 — — — —---- J/ — --------------------- 4'-0" 18'-2 1 /2" 1 82'-0" 9 1/8" 105-8 3/4" SIM. 9 1/8" s I Ln CV LO CV co M 0 0 0 0 0 FOUNDATION PLAN NOTES: A. DO NOT SCALE DRAWINGS, USE ONLY WRITTEN DIMENSIONS. B. ALL DIMENSIONS ARE TAKEN FROM OUT TO OUT OF STUD, UNLESS OTHERWISE NOTED. DIMENSIONS WITH +/— ARE TO BE FIELD VERIFIED BY CONTRACTOR. C. ALL FOOTINGS SHALL BEAR ON UNDISTURBED SOIL AT OR BELOW LOCAL FROST LINE MINIMUM. WHERE FOOTINGS ARE REQUIRED TO BE STEPPED, STEP DOWN IN VERTICAL INCREMENTS OF 2'-0" FOR EVERY 6'-0" MINIMUM OF HORIZONTAL DISTANCE. D. RAKE EXCAVATED MATERIALS BACK 12" MINIMUM FROM EDGES OF ALL EXCAVATIONS TO PREVENT LOOSE SOIL FROM FALLING BACK INTO TRENCH. E. PROVIDE CONTROL JOINTS ("C.J.") AND CONSTRUCTION JOINTS ("CONST. JT.") AS SHOWN ON PLANS. SOME CONSTRUCTION JOINT LOCATIONS SHOWN ON PLAN MAY BE OMITTED AS DIRECTED BY THE CONTRACTOR, HOWEVER ALL CONSTRUCTION JOINTS MUST FALL ON COLUMN LINES. REFER TO SHEET S300 FOR SLAB JOINT DETAILS. F. REFER TO ARCHITECTURAL SITE PLAN FOR EXTERIOR CONCRETE SIDEWALKS, STOOPS, ETC. WHICH SHALL HAVE BROOM FINISH PERPENDICULAR TO LINE OF TRAFFIC, UNLESS NOTED OTHERWISE. RAMPS AND OTHER INCLINED CONCRETE SURFACES TO HAVE COARSE, NON —SLIP STIFF —BRISTLED BROOM FINISH, PERPENDICULAR TO LINE OF TRAFFIC, UNLESS NOTED OTHERWISE. G. THE CONTRACTOR SHALL VERIFY THE SIZE AND LOCATION OF ALL PLUMBING, MECHANICAL AND ELECTRICAL REQUIREMENTS AND CLEARANCES PRIOR TO PROCEEDING WITH THE PROJECT. PENETRATIONS THROUGH THE STRUCTURE SHALL BE SUBJECT TO APPROVAL BY THE STRUCTURAL ENGINEER. H. PROVIDE TWO—PIECE BRICK TIES AT 16" O.C. HORIZONTAL AND VERTICAL TO SUPPORT BRICK AND STONE VENEER. I. COORDINATE FINIAL TOP OF SLAB ELEVATION WITH THICKNESS OF FLOOR FINISH MATERIALS TO DETERMINE RECESSED SLAB REQUIREMENTS. SEE DETAIL 8/S300. J. FOOTING SIZES ARE PRELIMINARY AND NEED TO BE UPDATED ONCE REACTIONS ARE RECIEVED FROM THE GLULAM MANUFACTURER. LINE KEY: = REINFORCED CONCRETE FOOTING = WOOD STUD WALL = CONCRETE TURNDOWN SLAB = CONTROL JOINT = THICKENED SLAB = CONCRETE WALL FOOTING SCHEDULE MARK SIZE REINFORCEMENT F-1 7'-0" x 7'-0" x 12" THICK (8) #5's E.W. ON BOTTOM F-2 4'-0" x 4'-0" x 12" THICK (5) #5's E.W. ON BOTTOM F-3 2'-0" x 2'-0" x 24" THICK (8) #6's VERT. & #3 TIES AT 6" O.C. WF-1 3'-0" x CONT. x 12" THICK (3) #5 REBAR CONT. WF-2 2'-0" x CONT. x 12" THICK (2) #5 REBAR CONT. WF-3 6'-0" x CONT. x 24" THICK (7) #6 REBAR CONT. TOP AND BOTTOM PIER SCHEDULE MARK SIZE REINFORCEMENT P-1 3'-0" x 2'-6" x 24" THICK (14) #6's VERT. & #3 TIES AT 6" O.C. P-2 2'-0" x 2'-0" x 24" THICK (8) #6's VERT. & #3 TIES AT 6" O.C. KEYNOTES: l 4" CONCRETE SLAB ON GRADE REINFORCED WITH 6x6 W1.4xW1.4 W.W.F. OVER 10 MIL. CLASS A NON— PERMEABLE VAPOR BARRIER OVER 4" MIN. 7 GRANULAR FILL. SEE NOTE "I" ABOVE. 2❑ 5" CONCRETE SLAB WITH 2 LAYERS OF 4x4x4/4 W.W.M. REINFORCING, REFER TO ICE RINK PLANS FOR ADDITIONAL INFORMATION. 3❑. RAISED SLAB AREA AS REQUIRED FOR TILE, SEE ARCHITECTURAL FOR REQUIREMENTS. GLULAM COLUMN, SEE ICE RINK PLANS. 1 N S30o 5❑ STEEL PIPE BOLLARD, SEE DETAIL 1/S305. EXISTING BUILDING AND FOUNDATIONS TO REMAIN. 7❑ #4 REBAR AT EACH SLAB CORNER FOR CRACK 2 CONTROL. ;300 a' 8 N FOUNDATION PLAN SCALE: 1 /8"=1 '—O" W Z � Q (If Z Q h LU 0 F V Z WLU J w a. W fir- �> U LL � DISCLAIMER: This is an original design, created by KJG Architecture, Inc. The concepts, ideas, plans and details are the sole property of KJG Architecture, Inc. one of the aforementioned shall be used by or disclosed to any person, firm or organization for any purpose without the prior written permission of KJG Architecture, Inc. PROFESSIONAL SEAL: PROJECT DATE: 09/14/2018 No. DESCRIPTION: DRAWN DATE BY: ISSUED: PROJECT NUMBER: DRAWN BY: A2018.078 ASW DRAWING TITLE: FOUNDATION PLAN SHEET NUMBER: S100 DATE: 11/26/18 William Hohlt