Loading...
HomeMy WebLinkAboutM003.0Indianapolis Design Center 352 South County Road 300 E Danville, IN 46122 317-745-9984 These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intended for product application assurance; and, is not intended to circumvent the need for a design professional as determined by the building codes. The designer of record and/or builder/framer is responsible to assure these drawings are compatible with the overall project. These documents are not intended to replace the building plan (which should be used to determine bearing placement). Please insure measurements of the foundation match those provided at the time of design. Builder is responsible to place load bearing members in load path. Architectural Drawings Prepared By: Pyatt Builders Structural Drawings Prepared By: 10/19/2018 84 Lumber 0707 Kevin Beher Pyatt Builders TG 35 Rev. By Date Comments FOR SUBMITTAL USE FIRST FLOOR SYTEM NOT TO SCALE Drawn By: CB Checked By: Date: 10/26/2018 1802684 Sheet 1 of 1 Confirm this layout with the builder and designer of record. Make sure all discrepencies are corrected before ordering floor system. All Dimensions are Approximate and Must Be Field Verified. Framing Connector Summary PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff H1 1 User HUS1.81/10 User Defined - - Not Required Not Required Not Required H2 1 Simpson HUS1.81/10 Designed 30- 10d common - 10- 10d common - - No No No H5 19 Simpson IUS2.06/11.88 Designed 10- 10d x 1-1/2 - - - - No No No H6 6 Simpson IUS2.37/11.88 Designed 10- 10d x 1-1/2 - - - - No No No Products PlotID Length Product Plies Net Qty F20' 20' 0" 11 7/8" TJI® 210 1 7 F18' 18' 0" 11 7/8" TJI® 210 1 3 F8' 8' 0" 11 7/8" TJI® 210 1 3 F6' 6' 0" 11 7/8" TJI® 210 1 6 F4' 4' 0" 11 7/8" TJI® 210 1 1 R42' 42' 0" 11 7/8" TJI® 360 1 7 R20' 20' 0" 11 7/8" TJI® 360 1 8 M1-2 24' 0" 1 3/4" x 24" 2.0E Microllam® LVL 2 2 M2-2 20' 0" 1 3/4" x 20" 2.0E Microllam® LVL 2 2 TS1-2 14' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 4 TS2-2 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 2 2 TS3 4' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand® LSL 1 3 STRm1 16' 0" 1 1/8" x 11 7/8" TJ® Rim Board 1 7 Accessories PlotID Length Product Plies Net Qty 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF 1 38 Blocking PlotID Length Product Plies Net Qty FBk1 2' 0" 11 7/8" TJI® 210 1 6 FBk2 2' 0" 11 7/8" TJI® 210 1 1 FBk1 1' 6" 11 7/8" TJI® 210 1 1 FBk2 1' 6" 11 7/8" TJI® 210 1 16 FBk1 1' 0" 11 7/8" TJI® 210 1 2 RBk1 2' 0" 11 7/8" TJI® 360 1 1 RBk1 1' 6" 11 7/8" TJI® 360 1 1 LEVEL NOTES Current Date: 10/31/2018 File Name: 2018-1127CB.jvl Level Name: First FLoor System TJ-Pro Rating (Weighted Average): 34 Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 31, joist = F18'(i3167) Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 67, joist = F8'(i3233) Building Code - Design Methodology: IBC 2006 FLOOR Floor Container: FC7 Use/Occupancy: ResidentialLivingAreas Floor Area Loading is: 30.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load Operator Added Additional Loads Maximum Allowed Deflection: L/480 Live Load & L/240 Total Load TJ-Pro Rating Information: Weighted Average: 34 Directly Applied Ceiling: Gypsum 1/2" Decking Attachment: Glue and Nail Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF Perpendicular Partition: No Strapping at max 8' o.c.: None Blocking at max 8' o.c.: No Poured Flooring: No Code Approved Rim Board Assembly PlotID Length Product Plies Net Qty STRm1 16' 0" 1 1/8" x 11 7/8" TJ® Rim Board 1 1 11 7/8" TJI-joists @ 19.2" o.c. 11 7/8" TJI-joists @ 24" o.c. 11 7/8" TJI-joists @ 24" o.c. B1 A3 A3 A3 H2 B1 E1 B1 B4 E1 E1 M2-2 BBO TS1-2 TS1-2 TS2-2 STRm1 STRm1 STRm1 STRm1 STRm1 STRm1 STRm1 STRm1 STRm1 STRm1 STRm1 F4' TS3 TS3 TS3 FBk2 FBk2 4' 6" 1' 9" 1' 5 15/16" H5 H5 H5 H5 H6 H5 H5 H5 H5 H6 H6 H5 H5 H5 H5 H5 H6 H5 H5 H2 H5 H6 H1 H5 F20' H6 M1-2 STRm1 FJ1 H5 H5 1' 7 3/4" 2' 0" 7 15/16" F18' F8' F6' F20' R20' FBk2 FBk1 FBk1 R42' RBk1 3/4” rim is not a code approved rim board assembly. Builder is responsible for proving a code approved rim board assembly. Roof is assumed to be a truss roof system with all the roof loads being transferred to exterior walls. No roof loads have been applied to the interior walls for the design of this structure unless shown on the roof truss layout. Please verify roof truss system prior to construction. Design Loads Floor Loads Live Load = 40 psf Live Load = 30 psf (Sleeping Area only) Dead Load = 10 psf Roof Load Snow Load = 20 psf Dead Load = 20 psf (4) 2x6's 11/21/18 Mike Sheeks