Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
S500.0
HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 HGUS26-2 Wall heights noted are from top of finished floor 8-06-14 TOP 8-06-14 TOP 8-06-14 TOP 8-06-14 TOP 8-06-14 TOP MUS26 MUS26 MUS26 MUS26 MUS26 MUS26 MUS26 MUS26 MUS26 MUS26 HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 HTU26 Framer to add solid blocking as needed to support hangers HTU26 MUS26 MUS26 11-05-00 TOB 12-01-02 TOP Stick frame No brick loads on trusses 10-01-02 TOP 10-01-02 TOP 10-01-02 TOP TG01 T01 T02 T03 T04 T05 T08 T09 T10 T11 T12 T13 TG02 TG03 T14 T15 TG04 J01 TG05 T17 TG06 M02 CG01 CG02 J02 J03 J04 J05 TG07 TG08 J06 J07 CG03 CG04 J08 J05 J04 J09 J10 J11 J03 TG05 TG05 J01 CG02 CG02 J02 J01 J02 J03 TG09 T18 T20 T21 J12 J13 TG10 T25 T25 TG10 J14 J15 CG05 CG05 M05 J16 J17 M05 J18 J19 TG11 TG12 T26 T27 T28 T29 T30 T31 CG06 CG06 J20 J21 J22 J23 J24 TG13 T36 T37 M07 CG06 J21 J25 J23 J26 TG14 J15 J14 TG10 T25 M04 CG05 J19 J18 M05 TG15 T38 T39 J27 TG16 TG16 J28 CG07 CG07 J29 J28 J29 J27 V01 V02 V03 V04 V05 V06 V07 V08 V09 V10 V11 V12 V13 V14 V15 V16 V17 V18 T06(2) T07(2) T16(4) M01(14) M03(13 ) M01(6) T19(3) T22(3) T23(3) T24(3) M04(6) T34(4) T35(3) M06(9) M06(2) M08(7) M09(11) T33(2) 11-10-00 6-00-00 7-00-00 23-11-00 21-10-00 21-02-00 2-02-00 3-08-00 23-08-00 13-00-00 29-03-00 43-04-00 15-05-00 23-04-00 20-00-00 49-07-00 37-09-00 11-10-00 11-10 11-10 11-10 6-13 4-13 IRC 2003 TPI 2002 20TLL- 10TDL- 10BDL Homes by McKenzie McCurdyResidence 295Westvale 1/4"=1' November 12, 2018 PH B18803340 CUSTOMER: LOCATION: MODEL: JOB #: DATE: DESIGNER: DESIGN INFORMATION: SCALE: 9028 Old SR 67 South Mooresville, IN 46158 (317) 834-5380 Truss Placement Guide 1) This layout is intended for the purpose of truss location and placement only. Refer to the building plans for actual building construction. 2) All dimensions shown 00-00-00 are in feet-inches-sixteenths. 3) Trusses are spaced 24" on center unless otherwise noted. 4) Do not cut or modify trusses. 5) Refer to the individual truss design drawings for the location of member bracing, uplift and truss end reactions. 6) Installation of all temporary and permanent bracing is essential. See truss drawings, BCSI-B2 Summary Sheet and building designer requirements. 7) Non-bearing walls may not be shown on layout. Left end of truss, as shown on engineering drawing, is indicated by the triangle symbol 11/16/18 Mike Sheeks