Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
I35298934.116_Woods_at_Shelborne
Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). Pages or sheets covered by this seal: I35298934 thru I35298990 My license renewal date for the state of Indiana is July 31, 2020. 116_Woods_at_Shelborne Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. IMPORTANT NOTE: 116 Woods at Shelborne 16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. November 13,2018 Johnson, Andrew Job 116_WOODS_AT_SHELBOR~E Truss GE01 Truss Type MONOPITCH SUPPORTED Qty 2 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298934 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:16:56 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-TsWXEK_lssZV7k45HVmRxhrE2aotT0F9ffeq7uyJZ4r Scale = 1:15.0 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 5 4 2x4 2x4 2x4 2x4 -1-0-0 1-0-0 1-11-8 1-11-8 1-1-02-4-118.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.13 0.03 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 5=160/1-11-8, 4=45/1-11-8 Max Horz 5=69(LC 5) Max Uplift 5=-30(LC 6), 4=-32(LC 5) Max Grav 5=160(LC 1), 4=48(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss GE02 Truss Type Monopitch Supported Gable Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298935 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:16:57 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-x24vRg?NdAhMkufHrCHgUuOQL_8mCTVIuJONfKyJZ4q Scale: 1"=1' Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 5 4 3x6 2x4 2x4 -1-0-0 1-0-0 3-3-8 3-3-8 0-9-01-10-34.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.05 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 5=203/3-3-8, 4=109/3-3-8 Max Horz 5=55(LC 5) Max Uplift 5=-48(LC 4), 4=-11(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss GE03 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298936 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:16:57 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-x24vRg?NdAhMkufHrCHgUuOQK_89CTEIuJONfKyJZ4q Scale = 1:21.3 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 3x8 4x6 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 9-7-8 9-7-8 -1-0-0 1-0-0 4-9-12 4-9-12 9-7-8 4-9-12 10-7-8 1-0-0 0-10-02-10-10-10-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.03 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 9 9 10 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 9-7-8. (lb) - Max Horz 16=31(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 16, 10, 14, 15, 12, 11 Max Grav All reactions 250 lb or less at joint(s) 16, 10, 13, 14, 15, 12, 11 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10, 14, 15, 12, 11. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss GE04 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298937 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:16:58 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-QEeHf00?OUpDM2EUOwov06xb3NUTxw5R6z7wCmyJZ4p Scale = 1:37.5 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 3x8 4x6 3x8 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 19-11-0 19-11-0 -1-0-0 1-0-0 9-11-8 9-11-8 19-11-0 9-11-8 20-11-0 1-0-0 0-10-04-11-130-10-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.02 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 17 17 18 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 194 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 19-11-0. (lb) - Max Horz 33=51(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 33, 18, 26, 27, 28, 29, 31, 32, 24, 23, 22, 21, 20, 19 Max Grav All reactions 250 lb or less at joint(s) 33, 18, 25, 26, 27, 28, 29, 31, 32, 24, 23, 22, 21, 20, 19 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 33, 18, 26, 27, 28, 29, 31, 32, 24, 23, 22, 21, 20, 19. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss GE05 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298938 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:16:59 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-uRCfsM0d9nx4_BpgydJ8ZJTmpnpegNabLdtUkDyJZ4o Scale = 1:27.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 3x8 4x6 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 14-11-0 14-11-0 -1-0-0 1-0-0 7-5-8 7-5-8 14-11-0 7-5-8 15-11-0 1-0-0 0-10-03-11-50-10-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.03 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 126 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 14-11-0. (lb) - Max Horz 24=41(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss GE06 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298939 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:01 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-qpJQH12ugPBoDVz242McekZ_2bOs824uoxMao5yJZ4m Scale: 1/4"=1' Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 19 18 17 15 14 13 12 11 10 9 8 52 16 4x6 3x6 3x4 3x4 3x4 3x4 8x8 8x8 5x6 8-5-13 8-5-13 14-11-0 6-5-3 16-9-3 1-10-3 25-3-0 8-5-13 -1-0-0 1-0-0 6-5-0 6-5-0 12-7-8 6-2-8 18-10-0 6-2-8 25-3-0 6-5-0 26-3-0 1-0-0 0-10-06-1-20-10-05.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-12], [2:0-1-12,0-0-12], [4:0-2-12,0-2-0], [4:0-3-0,0-0-1], [6:0-1-14,0-0-0], [8:0-1-4,0-6-0], [17:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.62 0.49 0.99 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.32 0.02 (loc) 18-19 18-19 8 l/defl >999 >556 n/a L/d 240 180 n/a PLATES MT20 Weight: 307 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-19,6-8: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 10-7-8 except (jt=length) 19=0-3-8, 16=0-3-8. (lb) - Max Horz 19=61(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 19 except 14=-107(LC 7), 8=-102(LC 7), 15=-347(LC 1) Max Grav All reactions 250 lb or less at joint(s) 13, 12, 11, 10, 9 except 14=1017(LC 1), 19=692(LC 1), 8=285(LC 11), 16=493(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-432/103, 3-4=-720/173, 4-5=0/270, 2-19=-387/146, 6-8=-300/156 BOT CHORD 18-19=-83/781, 16-18=0/263, 15-16=0/263, 14-15=0/263 WEBS 4-14=-778/96, 5-14=-400/184, 4-18=-51/577, 3-18=-346/172, 3-19=-500/76 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19 except (jt=lb) 14=107, 8=102, 15=347. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss GE07 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298940 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:02 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-I0toUN3WRiJfrfXFdmtrBy5H3?rWtkL11b58LXyJZ4l Scale = 1:25.8 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 3x8 4x6 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-11-0 13-11-0 -1-0-0 1-0-0 6-11-8 6-11-8 13-11-0 6-11-8 14-11-0 1-0-0 0-10-03-8-130-10-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.02 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 114 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 13-11-0. (lb) - Max Horz 24=-39(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss GE08 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298941 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:03 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-mCRAij38C0RWSp6RBTO4j9eFlOzmczQBGFrht_yJZ4k Scale = 1:46.0 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 16 15 14 13 12 11 10 9 8 4x6 4x8 3x8 8x8 8x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 6x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 6x8 2x4 2x4 2x4 2x4 2x4 8-4-0 8-4-0 10-11-12 2-7-12 21-11-8 10-11-12 -1-0-0 1-0-0 5-7-2 5-7-2 10-11-12 5-4-10 16-4-6 5-4-10 21-11-8 5-7-2 22-11-8 1-0-0 0-10-05-4-140-10-05.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-0-12], [2:Edge,0-3-0], [3:0-4-0,0-2-0], [5:0-4-0,0-2-0], [6:0-1-12,0-0-12], [8:Edge,0-3-0], [12:0-3-12,0-1-4], [12:0-0-0,0-1-12], [13:0-1-4,0-0-0], [19:0-1-6,0-1-0], [21:0-1-6,0-1-0], [29:0-1-6,0-1-0], [32:0-1-6,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.93 0.91 0.93 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.34 -0.89 0.05 (loc) 8-9 8-9 8 l/defl >480 >183 n/a L/d 240 180 n/a PLATES MT20 Weight: 241 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-16,6-8: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-10 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 9-10. REACTIONS.All bearings 8-4-0 except (jt=length) 8=0-3-8, 10=0-3-8, 10=0-3-8. (lb) - Max Horz 16=-55(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 8, 11, 10 except 16=-116(LC 6) Max Grav All reactions 250 lb or less at joint(s) 11, 13, 14, 15, 10, 10 except 16=839(LC 1), 8=902(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-329/121, 3-4=-1027/161, 4-5=-1027/161, 5-6=-495/35, 2-16=-333/146, 6-8=-395/113 BOT CHORD 15-16=-140/1137, 14-15=-140/1137, 13-14=-140/1137, 11-13=-140/1137, 10-11=-140/1137, 9-10=-140/1137, 8-9=-130/1156 WEBS 4-9=-1/483, 5-9=-339/170, 3-9=-318/181, 3-16=-1008/133, 5-8=-856/212 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 11, 10 except (jt=lb) 16=116. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss GE09 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298942 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:04 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-EO?Yv34mzKZN4zhdlAvJGNBdZoX_LesKVvaFPQyJZ4j Scale = 1:24.4 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 3x8 4x6 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-3-0 13-3-0 -1-0-0 1-0-0 6-7-8 6-7-8 13-3-0 6-7-8 14-3-0 1-0-0 0-10-03-7-20-10-05.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.09 0.02 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 107 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 13-3-0. (lb) - Max Horz 24=38(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 14, 20, 21, 22, 23, 18, 17, 16, 15. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss GE10 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298943 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:05 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-ibZx7P5OkdhEi6GqJuQYpajonCsq43jTjZKoxsyJZ4i Scale = 1:61.7 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 3x8 5x6 3x8 3x6 5x6 5x6 3x6 35-11-0 35-11-0 -1-0-0 1-0-0 17-11-8 17-11-8 35-11-0 17-11-8 36-11-0 1-0-0 0-10-08-3-130-10-05.00 12 Plate Offsets (X,Y)-- [4:0-3-0,0-3-0], [26:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.13 0.04 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 29 29 30 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 505 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 35-11-0. (lb) - Max Horz 58=-82(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 58, 30, 45, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31 Max Grav All reactions 250 lb or less at joint(s) 58, 30, 44, 45, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 43, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 58, 30, 45, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss GE11 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298944 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:06 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:BHm343G?TZ_4gsKviQ1PdzyNcdj-Bn7JKl60Vxp5JGr0sbxnLoGyNcBYpYFdyD3LUJyJZ4h Scale = 1:20.8 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 -1-0-0 1-0-0 10-0-0 10-0-0 0-8-83-7-83.50 12 Plate Offsets (X,Y)-- [9:0-1-15,0-0-11], [15:0-3-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.14 0.07 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 1 1 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 78 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 8-9: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-0-0. (lb) - Max Horz 15=109(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 15, 9, 10, 11, 12, 14 Max Grav All reactions 250 lb or less at joint(s) 15, 9, 10, 11, 12, 13, 14 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 9, 10, 11, 12, 14. 10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 9. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss J01 Truss Type MONO TRUSS Qty 3 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298945 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:07 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-fzhhY56eGFxxxQQCQJS0u?oz00SsY_ymBtpv0lyJZ4g Scale = 1:22.9 1 2 4 3 2x4 3x8 2x4 8-3-8 8-3-8 8-3-8 8-3-8 0-9-03-6-30-3-84.00 12 Plate Offsets (X,Y)-- [3:0-1-14,0-0-9] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-AS 0.78 0.39 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.31 -0.45 0.00 (loc) 3-4 3-4 l/defl >313 >212 n/a L/d 240 180 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 1-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS.(lb/size) 4=322/0-3-8, 3=322/0-1-8 Max Horz 4=91(LC 6) Max Uplift 4=-76(LC 4), 3=-114(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-4=-255/101 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 3=114. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss J02 Truss Type MONO TRUSS Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298946 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:07 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-fzhhY56eGFxxxQQCQJS0u?o3x0VyY?WmBtpv0lyJZ4g Scale = 1:17.3 1 2 4 3 3x8 2x4 2x4 5-3-8 5-3-8 5-3-8 5-3-8 0-9-02-6-30-3-84.00 12 Plate Offsets (X,Y)-- [1:0-0-7,0-1-4], [3:0-1-12,0-0-9], [4:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.41 0.26 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.07 -0.10 0.00 (loc) 3-4 3-4 l/defl >916 >639 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 4=203/0-3-8, 3=203/0-1-8 Max Horz 4=60(LC 6) Max Uplift 4=-47(LC 4), 3=-74(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 3. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss J03 Truss Type Jack-Open Qty 17 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298947 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:08 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-79E3lR7H1Y4oZa?P_0_FQDLE8PqfHSDwQXYSYByJZ4f Scale = 1:20.0 1 2 5 3 4 3x8 5-9-8 5-9-8 -1-0-0 1-0-0 5-9-8 5-9-8 0-10-03-2-152-10-93-2-155.00 12 Plate Offsets (X,Y)-- [5:0-4-4,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.44 0.29 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.04 -0.13 0.05 (loc) 4-5 4-5 3 l/defl >999 >516 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 5=299/0-3-8, 3=151/Mechanical, 4=65/Mechanical Max Horz 5=102(LC 6) Max Uplift 5=-34(LC 6), 3=-59(LC 6) Max Grav 5=299(LC 1), 3=151(LC 1), 4=106(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-253/132 NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss M01 Truss Type Monopitch Qty 5 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298948 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:08 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-79E3lR7H1Y4oZa?P_0_FQDLIMPuNHS5wQXYSYByJZ4f Scale = 1:15.0 1 2 3 5 4 2x4 2x4 3x4 2x4 1-10-12 1-10-12 -1-0-0 1-0-0 1-11-8 1-11-8 1-1-02-4-110-3-88.00 12 Plate Offsets (X,Y)-- [4:0-2-0,0-0-9] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.17 0.05 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 5 4-5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 5=160/0-3-8, 4=45/0-1-8 Max Horz 5=82(LC 6) Max Uplift 5=-12(LC 6), 4=-36(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss M02 Truss Type MONO TRUSS Qty 4 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298949 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:09 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-bMoRym8vosCfAkabYkVUzQuNap9z0vu3eBI05dyJZ4e Scale = 1:19.4 1 2 3 5 4 3x8 2x4 2x4 6-3-8 6-3-8 -1-0-0 1-0-0 6-3-8 6-3-8 0-9-02-10-30-3-84.00 12 Plate Offsets (X,Y)-- [4:0-2-2,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.52 0.35 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.18 0.00 (loc) 4-5 4-5 l/defl >999 >396 n/a L/d 240 180 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 5=317/0-3-8, 4=235/0-1-8 Max Horz 5=86(LC 6) Max Uplift 5=-44(LC 4), 4=-34(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-264/143 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss M03 Truss Type MONO TRUSS Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298950 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:09 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-bMoRym8vosCfAkabYkVUzQuNxp9q0vt3eBI05dyJZ4e Scale = 1:19.4 1 2 4 3 3x8 2x4 2x4 6-3-8 6-3-8 6-3-8 6-3-8 0-9-02-10-30-3-84.00 12 Plate Offsets (X,Y)-- [3:0-1-14,0-0-7] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.57 0.36 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.19 0.00 (loc) 3-4 3-4 l/defl >999 >383 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 4=242/0-3-8, 3=242/0-1-8 Max Horz 4=70(LC 6) Max Uplift 4=-6(LC 4), 3=-37(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 3. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss M04 Truss Type MONO TRUSS Qty 4 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298951 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:10 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-3YMqA69XZAKWou9n5R0jWeQaxDXslMHCtr1Zd4yJZ4d Scale = 1:17.3 1 2 3 5 4 3x8 2x4 2x4 5-3-8 5-3-8 -1-0-0 1-0-0 5-3-8 5-3-8 0-9-02-6-30-3-84.00 12 Plate Offsets (X,Y)-- [4:0-1-13,0-0-9] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.36 0.24 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.06 -0.09 0.00 (loc) 4-5 4-5 l/defl >974 >684 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 5=278/0-3-8, 4=194/0-1-8 Max Horz 5=76(LC 6) Max Uplift 5=-85(LC 4), 4=-71(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss M05 Truss Type Monopitch Qty 16 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298952 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:10 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:BHm343G?TZ_4gsKviQ1PdzyNcdj-3YMqA69XZAKWou9n5R0jWeQaBDXclJxCtr1Zd4yJZ4d Scale = 1:21.9 1 2 3 4 7 6 5 6x6 2x4 3x8 3x4 2x4 5-0-0 5-0-0 10-0-0 5-0-0 -1-0-0 1-0-0 5-0-0 5-0-0 10-0-0 5-0-0 0-8-83-7-80-3-83.50 12 Plate Offsets (X,Y)-- [4:0-1-12,0-1-8], [5:0-2-0,0-0-10], [7:0-1-11,0-0-8], [7:0-2-12,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.34 0.19 0.24 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.06 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 37 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 7=463/0-3-0, 5=386/0-1-8 Max Horz 7=109(LC 6) Max Uplift 7=-54(LC 4), 5=-49(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-650/79, 3-4=-659/143, 2-7=-415/131 WEBS 4-5=-344/120, 3-6=-324/177, 4-6=-187/706, 2-6=-11/363 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss MG01 Truss Type Monopitch Girder Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298953 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:11 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-XkwCNSA9KTSNQ1jzf9Xy2rzgIdiGUpzM6Vn69WyJZ4c Scale = 1:19.3 1 2 3 4 5 2x4 2x4 4x6 3x8 6-3-8 6-3-8 6-3-8 6-3-8 0-9-02-10-34.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.70 0.94 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.32 0.00 (loc) 1-3 1-3 3 l/defl >579 >223 n/a L/d 240 180 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-3-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 5-0-0 oc bracing. REACTIONS.(lb/size) 3=1754/Mechanical, 1=1024/0-3-8 Max Horz 1=81(LC 4) Max Uplift 3=-124(LC 5), 1=-66(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 3=124. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 763 lb down and 51 lb up at 2-0-12, and 763 lb down and 51 lb up at 4-0-12, and 772 lb down and 46 lb up at 6-1-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 1-3=-20 Concentrated Loads (lb) Vert: 3=-772(F) 4=-763(F) 5=-763(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T01 Truss Type Common Qty 5 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298954 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:12 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-?xUaboAn5naE1BIADs2Bb3Wrn14TD5ZVK9WghyyJZ4b Scale = 1:35.1 1 2 3 4 5 6 7 10 9 8 4x6 5x12 3x4 3x4 8x8 8x8 9-11-8 9-11-8 19-11-0 9-11-8 -1-0-0 1-0-0 5-1-0 5-1-0 9-11-8 4-10-8 14-10-0 4-10-8 19-11-0 5-1-0 20-11-0 1-0-0 0-10-04-11-130-10-05.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-0], [2:0-1-12,0-0-12], [3:0-1-8,0-1-8], [5:0-1-8,0-1-8], [6:Edge,0-3-0], [6:0-1-12,0-0-12], [9:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.65 0.75 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.48 0.04 (loc) 9-10 9-10 8 l/defl >999 >492 n/a L/d 240 180 n/a PLATES MT20 Weight: 72 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-6 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 10=854/0-3-8, 8=854/0-3-8 Max Horz 10=-51(LC 7) Max Uplift 10=-76(LC 6), 8=-76(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-388/40, 3-4=-1005/148, 4-5=-1005/148, 5-6=-388/40, 2-10=-344/110, 6-8=-344/110 BOT CHORD 9-10=-113/1087, 8-9=-113/1087 WEBS 4-9=-2/488, 5-9=-279/151, 3-9=-279/151, 3-10=-888/183, 5-8=-888/183 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 8. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T02 Truss Type Common Qty 4 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298955 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:12 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-?xUaboAn5naE1BIADs2Bb3Wrm14SD4zVK9WghyyJZ4b Scale = 1:34.0 1 2 3 4 5 6 9 8 7 4x6 8x8 5x12 3x4 3x4 8x8 9-11-8 9-11-8 19-11-0 9-11-8 -1-0-0 1-0-0 5-1-0 5-1-0 9-11-8 4-10-8 14-10-0 4-10-8 19-11-0 5-1-0 0-10-04-11-130-10-05.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-0], [2:0-1-12,0-0-12], [3:0-1-8,0-1-8], [5:0-1-8,0-1-8], [6:Edge,0-3-0], [6:0-1-12,0-0-12], [8:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.66 0.75 0.72 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.48 0.04 (loc) 8-9 8-9 7 l/defl >999 >491 n/a L/d 240 180 n/a PLATES MT20 Weight: 71 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-9,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-3 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 9=856/0-3-8, 7=783/Mechanical Max Horz 9=59(LC 6) Max Uplift 9=-76(LC 6), 7=-39(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-388/40, 3-4=-1009/150, 4-5=-1010/150, 5-6=-357/28, 2-9=-344/111 BOT CHORD 8-9=-141/1090, 7-8=-147/1103 WEBS 4-8=-5/490, 5-8=-293/157, 3-8=-279/151, 3-9=-892/185, 5-7=-937/201 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 7. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T03 Truss Type Common Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298956 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:13 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-T72yo8BPs5i5fLtMnZZQ7G21pQTfya1fZoGDEPyJZ4a Scale: 3/8"=1' 1 2 3 4 5 9 8 7 6 4x6 3x6 3x6 3x4 3x4 3x6 8x8 8-5-12 8-5-12 16-11-8 8-5-12 -1-0-0 1-0-0 5-1-0 5-1-0 9-11-8 4-10-8 16-11-8 7-0-0 0-10-04-11-132-0-135.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-0], [2:0-1-12,0-0-12], [3:0-1-12,0-1-8], [4:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.64 0.56 0.54 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.10 -0.27 0.03 (loc) 6-8 6-8 6 l/defl >999 >746 n/a L/d 240 180 n/a PLATES MT20 Weight: 62 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-6,2-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-6 REACTIONS.(lb/size) 6=664/Mechanical, 9=738/0-3-8 Max Horz 9=66(LC 6) Max Uplift 6=-25(LC 7), 9=-74(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-342/63, 3-4=-817/133, 5-6=-253/114, 2-9=-328/121 BOT CHORD 8-9=-110/884, 6-8=-12/602 WEBS 3-8=-260/136, 4-8=0/427, 4-6=-602/23, 3-9=-705/118 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 9. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T04 Truss Type Common Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298957 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:13 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-T72yo8BPs5i5fLtMnZZQ7G21?QVLyhvfZoGDEPyJZ4a Scale = 1:28.7 1 2 3 4 5 8 7 6 4x6 8x8 8x8 3x8 7-5-8 7-5-8 14-11-0 7-5-8 -1-0-0 1-0-0 7-5-8 7-5-8 14-11-0 7-5-8 15-11-0 1-0-0 0-10-03-11-50-10-05.00 12 Plate Offsets (X,Y)-- [6:Edge,0-5-11], [6:0-1-12,0-0-0], [8:0-1-12,0-0-0], [8:Edge,0-5-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.62 0.38 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.15 0.01 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 53 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8,4-6: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-10-1 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 8=654/0-3-8, 6=654/0-3-8 Max Horz 8=41(LC 6) Max Uplift 8=-66(LC 6), 6=-66(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-792/121, 3-4=-792/121, 2-8=-589/173, 4-6=-589/173 BOT CHORD 7-8=-134/509, 6-7=-120/509 WEBS 3-7=0/294, 2-7=-19/289, 4-7=-19/289 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T05 Truss Type Common Qty 2 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298958 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:14 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-yJcK0UC2dOqyHVSYKH4fgUb8CqnEh0pooS?nmryJZ4Z Scale = 1:43.7 1 2 3 4 5 6 7 12 11 10 9 813 4x6 3x6 3x4 3x4 3x4 3x4 8x8 8x8 8-5-13 8-5-13 16-9-3 8-3-5 25-3-0 8-5-13 -1-0-0 1-0-0 6-5-0 6-5-0 12-7-8 6-2-8 18-10-0 6-2-8 25-3-0 6-5-0 26-3-0 1-0-0 0-10-06-1-20-10-05.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-0-12], [2:Edge,0-2-8], [6:0-1-12,0-0-12], [6:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.85 0.66 0.63 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.25 -0.42 0.07 (loc) 9-11 9-11 8 l/defl >999 >710 n/a L/d 240 180 n/a PLATES MT20 Weight: 91 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-12,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-12, 5-8 REACTIONS.(lb/size) 12=1122/0-3-8, 8=1122/0-3-8 Max Horz 12=61(LC 6) Max Uplift 12=-87(LC 6), 8=-87(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-532/115, 3-4=-1685/257, 4-5=-1685/257, 5-6=-532/115, 2-12=-435/152, 6-8=-435/152 BOT CHORD 11-12=-140/1626, 9-11=-25/1169, 8-9=-140/1626 WEBS 4-9=-38/574, 5-9=-282/165, 4-11=-38/574, 3-11=-282/165, 3-12=-1351/146, 5-8=-1351/146 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 8. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T06 Truss Type Common Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298959 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:15 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-QW9jDqDgNiypuf1lu_cuDh8KmE3oQOwy16lKIHyJZ4Y Scale = 1:38.4 1 2 3 4 5 6 7 10 9 8 4x6 5x12 3x4 3x4 8x8 8x8 10-11-12 10-11-12 21-11-8 10-11-12 -1-0-0 1-0-0 5-7-2 5-7-2 10-11-12 5-4-10 16-4-6 5-4-10 21-11-8 5-7-2 22-11-8 1-0-0 0-10-05-4-140-10-05.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-0], [2:0-1-12,0-0-12], [3:0-1-8,0-1-8], [5:0-1-8,0-1-8], [6:Edge,0-3-0], [6:0-1-12,0-0-12], [9:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.80 0.90 0.90 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.27 -0.70 0.05 (loc) 8-9 8-9 8 l/defl >953 >371 n/a L/d 240 180 n/a PLATES MT20 Weight: 79 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-11 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 2-2-0 oc bracing. REACTIONS.(lb/size) 10=935/0-3-8, 8=935/0-3-8 Max Horz 10=-55(LC 7) Max Uplift 10=-80(LC 6), 8=-80(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-466/44, 3-4=-1124/164, 4-5=-1124/164, 5-6=-466/44, 2-10=-385/117, 6-8=-385/117 BOT CHORD 9-10=-134/1231, 8-9=-134/1231 WEBS 4-9=-4/549, 5-9=-325/170, 3-9=-325/170, 3-10=-970/206, 5-8=-970/206 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 8. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T07 Truss Type Common Qty 9 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298960 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:15 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-QW9jDqDgNiypuf1lu_cuDh8JHE61QRXy16lKIHyJZ4Y Scale = 1:60.8 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 3x6 5x6 3x6 8x8 3x6 4x8 3x4 3x6 3x4 3x6 3x6 8x8 9-1-0 9-1-0 17-11-8 8-10-8 26-10-0 8-10-8 35-11-0 9-1-0 -1-0-0 1-0-0 9-1-0 9-1-0 17-11-8 8-10-8 26-10-0 8-10-8 35-11-0 9-1-0 36-11-0 1-0-0 0-10-08-3-130-10-05.00 12 Plate Offsets (X,Y)-- [3:0-1-12,0-1-8], [7:0-1-12,0-1-8], [10:0-2-9,0-1-1], [10:0-3-0,0-2-0], [11:0-2-0,0-1-8], [15:0-2-0,0-1-8], [16:0-2-9,0-1-1], [16:0-3-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.89 0.75 0.73 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.49 0.11 (loc) 10-11 11-13 10 l/defl >999 >874 n/a L/d 240 180 n/a PLATES MT20 Weight: 132 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-16,8-10: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-13, 3-13 REACTIONS.(lb/size) 16=1492/0-3-8, 10=1492/0-3-8 Max Horz 16=-83(LC 7) Max Uplift 16=-111(LC 6), 10=-111(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2589/351, 3-5=-1853/319, 5-7=-1853/319, 7-8=-2589/351, 2-16=-1404/278, 8-10=-1404/278 BOT CHORD 15-16=-170/762, 13-15=-201/2295, 11-13=-201/2295, 10-11=-131/762 WEBS 5-13=-55/850, 7-13=-814/179, 7-11=0/282, 3-13=-814/179, 3-15=0/282, 2-15=-70/1537, 8-11=-70/1537 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 16=111, 10=111. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T08 Truss Type COMMON Qty 7 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298961 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:16 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-uij5QADI804gWpcxSi77lvgTzeSG9ul5FmUtqjyJZ4X Scale = 1:60.0 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 3x6 5x6 3x6 8x8 3x6 3x4 3x6 4x8 3x4 4x6 10x10 3x6 9-1-0 9-1-0 17-11-8 8-10-8 26-8-4 8-8-12 35-7-8 8-11-4 -1-0-0 1-0-0 9-1-0 9-1-0 17-11-8 8-10-8 26-8-4 8-8-12 35-7-8 8-11-4 0-10-08-3-130-11-75.00 12 Plate Offsets (X,Y)-- [3:0-1-12,0-1-8], [7:0-1-12,0-1-8], [8:Edge,0-7-11], [9:0-1-12,0-0-0], [10:0-2-8,0-2-0], [14:0-2-0,0-1-8], [15:0-2-9,0-1-1], [15:0-3-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.90 0.75 0.73 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.48 0.10 (loc) 9-10 12-14 9 l/defl >999 >885 n/a L/d 240 180 n/a PLATES MT20 Weight: 130 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 6-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-15: 2x6 SPF No.2, 8-9: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-12, 7-12 REACTIONS.(lb/size) 15=1485/0-3-8, 9=1409/Mechanical Max Horz 15=92(LC 6) Max Uplift 15=-111(LC 6), 9=-71(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2574/350, 3-5=-1835/318, 5-7=-1835/320, 7-8=-2534/349, 2-15=-1397/278, 8-9=-1321/223 BOT CHORD 14-15=-178/758, 12-14=-229/2281, 10-12=-230/2255, 9-10=-63/467 WEBS 3-14=0/284, 3-12=-816/180, 5-12=-60/850, 7-12=-797/182, 7-10=0/257, 2-14=-72/1528, 8-10=-167/1794 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9 except (jt=lb) 15=111. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T09 Truss Type Common Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298962 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:17 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-MuHTeWEwvJCX8yB70PeMI6DeZ2oKuLWEUQERNAyJZ4W Scale = 1:60.3 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 3x6 5x6 3x6 8x8 3x6 4x8 3x4 3x6 3x4 3x8 3x6 8x8 9-1-0 9-1-0 17-11-8 8-10-8 26-10-0 8-10-8 35-11-0 9-1-0 9-1-0 9-1-0 17-11-8 8-10-8 26-10-0 8-10-8 35-11-0 9-1-0 36-11-0 1-0-0 0-10-08-3-130-10-05.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-1-8], [6:0-1-12,0-1-8], [9:0-2-9,0-1-1], [9:0-3-0,0-2-0], [10:0-2-0,0-1-8], [14:0-2-8,0-1-8], [15:0-1-12,0-0-0], [15:Edge,0-5-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.91 0.77 0.76 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.48 0.11 (loc) 14-15 10-12 9 l/defl >999 >880 n/a L/d 240 180 n/a PLATES MT20 Weight: 131 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-3: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-15: 2x4 SP 2400F 2.0E, 7-9: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-12, 2-12 REACTIONS.(lb/size) 15=1420/Mechanical, 9=1497/0-3-8 Max Horz 15=-91(LC 7) Max Uplift 15=-72(LC 6), 9=-111(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2626/360, 2-4=-1866/323, 4-6=-1863/322, 6-7=-2599/354, 1-15=-1331/226, 7-9=-1409/279 BOT CHORD 14-15=-106/603, 12-14=-214/2339, 10-12=-203/2305, 9-10=-131/761 WEBS 4-12=-61/868, 6-12=-814/180, 6-10=0/282, 2-12=-851/191, 2-14=0/285, 1-14=-155/1739, 7-10=-73/1547 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15 except (jt=lb) 9=111. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T10 Truss Type Common Qty 2 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298963 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:17 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-MuHTeWEwvJCX8yB70PeMI6DfV2oIuLVEUQERNAyJZ4W Scale = 1:59.8 1 2 3 4 5 6 7 14 13 12 11 10 9 8 3x6 5x6 3x6 8x8 3x6 4x8 3x4 3x8 3x4 3x8 8x8 3x6 9-1-0 9-1-0 17-11-8 8-10-8 26-10-0 8-10-8 35-11-0 9-1-0 9-1-0 9-1-0 17-11-8 8-10-8 26-10-0 8-10-8 35-11-0 9-1-0 0-10-08-3-130-10-05.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-1-8], [6:0-1-12,0-1-8], [7:Edge,0-5-11], [8:0-1-12,0-0-0], [9:0-2-8,0-1-8], [13:0-2-8,0-1-8], [14:0-1-12,0-0-0], [14:Edge,0-5-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.85 0.77 0.77 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.48 0.11 (loc) 8-9 9-11 8 l/defl >999 >890 n/a L/d 240 180 n/a PLATES MT20 Weight: 129 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-3,5-7: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-14,7-8: 2x4 SPF 2100F 1.8E BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-11, 2-11 REACTIONS.(lb/size) 14=1425/Mechanical, 8=1425/0-3-8 Max Horz 14=-70(LC 7) Max Uplift 14=-72(LC 6), 8=-72(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2637/363, 2-4=-1876/325, 4-6=-1876/325, 6-7=-2637/363, 1-14=-1335/227, 7-8=-1335/227 BOT CHORD 13-14=-114/601, 11-13=-244/2349, 9-11=-244/2349, 8-9=-84/601 WEBS 4-11=-67/885, 6-11=-851/192, 6-9=0/285, 2-11=-851/192, 2-13=0/285, 1-13=-160/1752, 7-9=-160/1752 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 8. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T11 Truss Type Hip Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298964 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:18 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-q5rrrrFYgdKOm6mKZ79bqKmrVR7adoJOj4z_vcyJZ4V Scale = 1:62.3 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 3x6 5x12 3x6 8x8 3x6 3x4 4x6 3x4 3x4 3x4 4x6 8x8 3x6 9-0-0 9-0-0 17-9-8 8-9-8 18-1-8 0-4-0 26-11-0 8-9-8 35-11-0 9-0-0 9-0-0 9-0-0 17-9-8 8-9-8 18-1-8 0-4-0 26-11-0 8-9-8 35-11-0 9-0-0 0-10-08-2-150-10-08-2-155.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-1-8], [4:0-6-0,0-2-2], [7:0-1-12,0-1-8], [8:Edge,0-5-11], [9:0-1-12,0-0-0], [10:0-2-8,0-2-0], [15:0-2-8,0-2-0], [16:0-1-12,0-0-0], [16:Edge,0-5-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.83 0.76 0.73 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.47 0.11 (loc) 9-10 13-15 9 l/defl >999 >901 n/a L/d 240 180 n/a PLATES MT20 Weight: 135 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5: 2x6 SPF No.2, 1-3,6-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-16,8-9: 2x4 SPF 2100F 1.8E BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (5-4-15 max.): 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-13, 7-12 REACTIONS.(lb/size) 16=1425/Mechanical, 9=1425/Mechanical Max Horz 16=-69(LC 7) Max Uplift 16=-72(LC 6), 9=-72(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2639/361, 2-4=-1899/327, 4-5=-1644/339, 5-7=-1899/327, 7-8=-2639/361, 1-16=-1336/226, 8-9=-1336/226 BOT CHORD 15-16=-111/595, 13-15=-243/2351, 12-13=-75/1644, 10-12=-243/2351, 9-10=-83/595 WEBS 2-15=0/282, 2-13=-841/186, 4-13=-31/448, 5-12=-31/448, 7-12=-841/186, 7-10=0/282, 1-15=-160/1760, 8-10=-160/1760 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 9. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T12 Truss Type Hip Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298965 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:19 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-IHPD3BGARxSENGLW7qgqNXIz5rUsMGoXxkjXR2yJZ4U Scale = 1:61.7 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 3x6 5x8 5x6 3x6 8x8 3x6 3x4 4x6 3x4 3x8 3x4 4x6 8x8 3x6 8-0-0 8-0-0 15-9-8 7-9-8 20-1-8 4-4-0 27-11-0 7-9-8 35-11-0 8-0-0 8-0-0 8-0-0 15-9-8 7-9-8 20-1-8 4-4-0 27-11-0 7-9-8 35-11-0 8-0-0 0-10-07-4-150-10-07-4-155.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-1-8], [4:0-5-12,0-2-8], [5:0-3-0,0-2-4], [7:0-1-12,0-1-8], [8:Edge,0-5-11], [9:0-1-12,0-0-0], [10:0-2-8,0-2-0], [15:0-2-8,0-2-0], [16:0-1-12,0-0-0], [16:Edge,0-5-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.97 0.70 0.65 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.50 0.11 (loc) 13-15 13-15 9 l/defl >999 >856 n/a L/d 240 180 n/a PLATES MT20 Weight: 136 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-16,8-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-2-3 max.): 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-13, 4-12, 7-12 REACTIONS.(lb/size) 16=1425/Mechanical, 9=1425/Mechanical Max Horz 16=-61(LC 7) Max Uplift 16=-63(LC 6), 9=-63(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2654/348, 2-4=-2029/324, 4-5=-1785/332, 5-7=-2030/324, 7-8=-2654/348, 1-16=-1344/214, 8-9=-1344/214 BOT CHORD 15-16=-99/490, 13-15=-239/2374, 12-13=-95/1784, 10-12=-239/2374, 9-10=-70/490 WEBS 2-13=-690/160, 4-13=-4/444, 5-12=-4/445, 7-12=-689/161, 1-15=-170/1890, 8-10=-170/1889 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 9. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T13 Truss Type Hip Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298966 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:20 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-mTzcGXHoCEa5?QvihXB3wlrAIFmO5i7hAOS5zVyJZ4T Scale = 1:61.8 1 2 3 4 5 6 14 13 12 11 10 9 8 715 8x8 5x8 5x8 8x8 3x8 3x4 4x6 3x4 3x8 3x4 4x6 3x6 7-0-0 7-0-0 13-9-8 6-9-8 22-1-8 8-4-0 28-11-0 6-9-8 35-11-0 7-0-0 7-0-0 7-0-0 13-9-8 6-9-8 22-1-8 8-4-0 28-11-0 6-9-8 35-11-0 7-0-0 0-10-06-6-150-10-06-6-155.00 12 Plate Offsets (X,Y)-- [1:Edge,0-5-11], [2:0-1-12,0-1-8], [3:0-4-8,0-2-0], [4:0-4-0,0-1-13], [5:0-1-12,0-1-8], [6:Edge,0-5-11], [7:0-1-12,0-0-0], [8:0-2-4,0-2-0], [13:0-2-4,0-2-0], [14:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.88 0.93 0.71 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.25 -0.58 0.12 (loc) 9-12 9-12 7 l/defl >999 >740 n/a L/d 240 180 n/a PLATES MT20 Weight: 131 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-4: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-14,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-4 oc purlins, except end verticals, and 2-0-0 oc purlins (4-1-14 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 12-13. WEBS 1 Row at midpt 3-9 REACTIONS.(lb/size) 14=1498/Mechanical, 7=1481/Mechanical Max Horz 14=-53(LC 7) Max Uplift 14=-54(LC 6), 7=-54(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2794/336, 2-3=-2379/320, 3-4=-2084/325, 4-5=-2332/320, 5-6=-2758/336, 1-14=-1418/205, 6-7=-1401/205 BOT CHORD 13-14=-79/455, 12-13=-236/2510, 9-12=-117/2127, 8-9=-236/2476, 7-8=-56/450 WEBS 2-12=-458/132, 3-12=0/482, 4-9=0/462, 5-9=-469/133, 1-13=-180/2062, 6-8=-181/2034 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 7. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T14 Truss Type Hip Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298967 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:20 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-mTzcGXHoCEa5?QvihXB3wlrEpFq05guhAOS5zVyJZ4T Scale = 1:61.9 1 2 3 4 5 6 7 14 13 12 11 10 9 8 8x8 5x6 5x6 8x8 3x6 3x8 3x8 2x4 3x8 3x8 3x8 3x6 11-9-8 11-9-8 17-11-8 6-2-0 24-1-8 6-2-0 35-11-0 11-9-8 6-0-0 6-0-0 11-9-8 5-9-8 17-11-8 6-2-0 24-1-8 6-2-0 29-11-0 5-9-8 35-11-0 6-0-0 0-10-05-8-150-10-05-8-155.00 12 Plate Offsets (X,Y)-- [1:0-1-12,0-0-12], [1:Edge,0-2-12], [3:0-3-0,0-2-4], [5:0-3-0,0-2-4], [7:0-1-12,0-0-12], [7:Edge,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.59 0.70 0.85 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.39 -1.02 0.13 (loc) 8-9 8-9 8 l/defl >999 >419 n/a L/d 240 180 n/a PLATES MT20 Weight: 131 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 10-12: 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-14,7-8: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-3 oc purlins, except end verticals, and 2-0-0 oc purlins (3-8-5 max.): 3-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-14, 6-8 REACTIONS.(lb/size) 14=1425/Mechanical, 8=1425/Mechanical Max Horz 14=-46(LC 7) Max Uplift 14=-43(LC 6), 8=-43(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-630/18, 2-3=-2348/297, 3-4=-2110/300, 4-5=-2110/300, 5-6=-2348/297, 6-7=-630/18, 1-14=-376/57, 7-8=-376/57 BOT CHORD 13-14=-283/2301, 11-13=-179/2365, 9-11=-179/2365, 8-9=-283/2301 WEBS 3-13=0/559, 4-13=-466/86, 4-9=-466/86, 5-9=0/559, 2-14=-2023/372, 6-8=-2023/372 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 8. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T15 Truss Type Hip Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298968 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:21 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-EgX_UtHRzYiydaUuFFjISyOKrf6BqAxqP2CeWxyJZ4S Scale = 1:61.9 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 8x8 5x6 3x8 5x6 8x8 3x8 MT18HS3x8 3x8 2x4 3x8 3x8 3x8 3x8 MT18HS 9-9-8 9-9-8 17-11-8 8-2-0 26-1-8 8-2-0 35-11-0 9-9-8 5-0-0 5-0-0 9-9-8 4-9-8 17-11-8 8-2-0 26-1-8 8-2-0 30-11-0 4-9-8 35-11-0 5-0-0 0-10-04-10-150-10-04-10-155.00 12 Plate Offsets (X,Y)-- [1:0-1-12,0-0-12], [1:Edge,0-3-0], [3:0-3-0,0-2-4], [6:0-3-0,0-2-4], [8:0-1-12,0-0-12], [8:Edge,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.95 0.90 0.67 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.24 -0.67 0.18 (loc) 14-15 14-15 9 l/defl >999 >640 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 127 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-15,8-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-6-7 oc purlins, except end verticals, and 2-0-0 oc purlins (2-2-0 max.): 3-6. BOT CHORD Structural wood sheathing directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 4-14, 4-10, 2-15, 7-9 REACTIONS.(lb/size) 15=1425/Mechanical, 9=1425/Mechanical Max Horz 15=38(LC 6) Max Uplift 15=-36(LC 4), 9=-36(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-483/29, 2-3=-2468/297, 3-4=-2241/298, 4-6=-2241/298, 6-7=-2468/297, 7-8=-483/29, 1-15=-313/54, 8-9=-313/54 BOT CHORD 14-15=-262/2267, 12-14=-232/2851, 10-12=-232/2851, 9-10=-262/2267 WEBS 3-14=0/581, 4-14=-813/100, 4-12=0/284, 4-10=-813/100, 6-10=0/581, 2-15=-2132/331, 7-9=-2133/332 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 9. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss T16 Truss Type Hip Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298969 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:22 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-js5MhDI3ksqpEk35oyEX?9waI3S?ZdY_eixC2NyJZ4R Scale = 1:61.8 1 2 3 4 5 6 7 14 13 12 11 10 9 8 8x8 5x8 3x6 5x8 8x8 3x8 MT18HS4x8 3x4 3x4 3x4 4x8 3x8 MT18HS 7-9-8 7-9-8 17-11-8 10-2-0 28-1-8 10-2-0 35-11-0 7-9-8 7-9-8 7-9-8 14-6-13 6-9-5 21-4-3 6-9-5 28-1-8 6-9-5 35-11-0 7-9-8 0-10-04-0-150-10-04-0-155.00 12 Plate Offsets (X,Y)-- [1:Edge,0-5-11], [2:0-4-0,0-1-13], [6:0-4-0,0-1-13], [7:Edge,0-5-11], [8:0-1-12,0-0-0], [9:0-1-12,0-2-4], [13:0-3-12,0-2-4], [14:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.59 0.92 0.65 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.25 -0.79 0.15 (loc) 11 9-11 8 l/defl >999 >542 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 122 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E *Except* 2-4,4-6: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 10-12: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 1-14,7-8: 2x4 SPF 2100F 1.8E BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-1 oc purlins, except end verticals, and 2-0-0 oc purlins (2-9-7 max.): 2-6. BOT CHORD Structural wood sheathing directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 3-13, 5-9 REACTIONS.(lb/size) 14=1425/Mechanical, 8=1425/Mechanical Max Horz 14=30(LC 6) Max Uplift 14=-55(LC 4), 8=-55(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2623/279, 2-3=-2351/293, 3-5=-3367/361, 5-6=-2351/293, 6-7=-2623/279, 1-14=-1351/193, 7-8=-1351/193 BOT CHORD 13-14=-107/558, 11-13=-294/3271, 9-11=-294/3271, 8-9=-107/558 WEBS 2-13=0/611, 3-13=-1150/145, 3-11=0/284, 5-11=0/284, 5-9=-1150/145, 6-9=0/611, 1-13=-64/1782, 7-9=-64/1782 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 8. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss TG01 Truss Type Common Girder Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298970 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:23 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-B2ekvZJhV9ygsteHMglmXNTq9SwkI817sMhlapyJZ4Q Scale = 1:19.2 1 2 3 4 5 67 8 9 5x8 3x6 4x6 5x8 3x6 3x6 4-9-12 4-9-12 9-7-8 4-9-12 4-9-12 4-9-12 9-7-8 4-9-12 0-10-02-10-10-10-05.00 12 Plate Offsets (X,Y)-- [1:0-0-12,0-2-4], [5:0-0-12,0-2-15] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.26 0.44 0.44 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.06 0.01 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 36 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 2-6-10, Right 2x4 SPF-S Stud 2-6-10 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-8 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=833/0-3-8, 5=1030/0-3-8 Max Horz 1=23(LC 5) Max Uplift 1=-150(LC 5), 5=-209(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1334/273, 3-5=-1329/272 BOT CHORD 1-6=-205/1137, 5-6=-205/1137 WEBS 3-6=-158/810 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=150, 5=209. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 302 lb down and 88 lb up at 3-0-12, 302 lb down and 88 lb up at 5-0-12, and 302 lb down and 88 lb up at 7-0-12, and 188 lb down and 56 lb up at 9-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 1-5=-20 Concentrated Loads (lb) Vert: 6=-302(F) 7=-302(F) 8=-302(F) 9=-188 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss TG02 Truss Type Common Girder Qty 1 Ply 2 116 Woods at Shelborne Job Reference (optional) I35298971 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:23 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-B2ekvZJhV9ygsteHMglmXNTnfSqSI2a7sMhlapyJZ4Q Scale = 1:42.1 1 2 3 4 5 6 10 9 8 711 12 13 14 15 16 17 18 19 6x16 5x8 7x16 MT18HS 12x12 4x8 3x12 4x8 3x12 6x16 6-5-0 6-5-0 12-7-8 6-2-8 18-10-0 6-2-8 25-3-0 6-5-0 6-5-0 6-5-0 12-7-8 6-2-8 18-10-0 6-2-8 25-3-0 6-5-0 26-3-0 1-0-0 0-10-06-1-20-10-05.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-0-10], [2:0-2-8,0-1-12], [3:0-3-12,0-2-8], [4:0-2-8,0-1-12], [5:Edge,0-0-10], [8:0-6-0,0-6-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.49 0.78 0.79 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.46 0.13 (loc) 7-8 7-8 5 l/defl >999 >656 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 342 lb FT = 20% GRIP 169/123 244/190 LUMBER- TOP CHORD 2x6 SP 2400F 2.0E BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 3-8: 2x4 SPF 2100F 1.8E, 4-7,2-10: 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-11 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-8, 2-8 REACTIONS.(lb/size) 1=9585/0-3-8 (req. 0-4-0), 5=7756/0-3-8 Max Horz 1=-58(LC 6) Max Uplift 1=-547(LC 5), 5=-539(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-17607/1002, 2-3=-12565/728, 3-4=-12556/729, 4-5=-17006/1086 BOT CHORD 1-10=-899/15896, 8-10=-899/15896, 7-8=-916/15282, 5-7=-916/15282 WEBS 3-8=-457/9089, 4-8=-4147/449, 4-7=-263/3955, 2-8=-4827/366, 2-10=-181/4368 NOTES-(11-12) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) WARNING: Required bearing size at joint(s) 1 greater than input bearing size. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=547, 5=539. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1400 lb down and 84 lb up at 1-4-12, 1405 lb down and 84 lb up at 3-4-12, 1405 lb down and 84 lb up at 5-4-12, 1405 lb down and 84 lb up at 7-4-12, 1405 lb down and 75 lb up at 9-4-12, 1478 lb down and 66 lb up at 11-4-12, 1405 lb down and 55 lb up at 13-4-12, 1405 lb down and 48 lb up at 15-4-12, and 1405 lb down and 67 lb up at 17-4-12, and 2562 lb down and 302 lb up at 19-4-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).Continued on page 2 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss TG02 Truss Type Common Girder Qty 1 Ply 2 116 Woods at Shelborne Job Reference (optional) I35298971 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:23 2018 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-B2ekvZJhV9ygsteHMglmXNTnfSqSI2a7sMhlapyJZ4Q LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-6=-60, 1-5=-20 Concentrated Loads (lb) Vert: 9=-1405(B) 11=-1400(B) 12=-1405(B) 13=-1405(B) 14=-1405(B) 15=-1478(B) 16=-1405(B) 17=-1405(B) 18=-1405(B) 19=-2562(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 116_WOODS_AT_SHELBOR~E Truss TG03 Truss Type Common Girder Qty 1 Ply 2 116 Woods at Shelborne Job Reference (optional) I35298972 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:24 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-fEC66vKJGT5XU1DTwNG?4a0xxs6G1USG50QI6GyJZ4P Scale = 1:36.8 1 2 3 4 5 6 7 8 12 11 10 913 14 15 16 17 18 6x16 8x16 5x8 6x18 MT18HS 10x10 4x6 3x8 4x6 3x8 6x16 8x16 5-7-10 5-7-10 10-11-12 5-4-2 16-3-14 5-4-2 21-11-8 5-7-10 5-7-10 5-7-10 10-11-12 5-4-2 16-3-14 5-4-2 21-11-8 5-7-10 22-11-8 1-0-0 0-10-05-4-140-10-05.00 12 Plate Offsets (X,Y)-- [1:0-4-9,0-0-0], [1:1-7-6,0-3-0], [1:0-1-12,0-0-12], [1:0-0-12,0-2-12], [3:0-1-12,0-2-0], [5:0-1-12,0-2-0], [7:0-10-14,0-0-12], [7:0-11-0,0-6-8], [7:0-4-9,0-0-0], [7:0-0-12,0-2-12], [9:0-4-12,0-1-8], [12:0-4-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.52 1.00 0.88 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.38 0.12 (loc) 9-10 9-10 7 l/defl >999 >679 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 298 lb FT = 20% GRIP 169/123 244/190 LUMBER- TOP CHORD 2x6 SP 2400F 2.0E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF No.2 *Except* 5-10,3-10: 2x4 SPF-S Stud SLIDER Left 2x8 SP 2400F 2.0E 2-9-13, Right 2x8 SP 2400F 2.0E 2-9-13 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-13 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=7782/0-3-8, 7=6475/0-3-8 Max Horz 1=-49(LC 6) Max Uplift 1=-437(LC 5), 7=-468(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-14177/792, 3-4=-10461/615, 4-5=-10448/615, 5-7=-13546/912 BOT CHORD 1-12=-706/12736, 10-12=-706/12736, 9-10=-757/12055, 7-9=-757/12055 WEBS 4-10=-361/7160, 5-10=-2684/366, 5-9=-253/3198, 3-10=-3447/253, 3-12=-127/3587 NOTES-(10-11) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 5-9 2x4 - 1 row at 0-2-0 oc, member 3-12 2x4 - 1 row at 0-2-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=437, 7=468. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1405 lb down and 84 lb up at 2-1-4, 1405 lb down and 84 lb up at 4-1-4, 1405 lb down and 75 lb up at 6-1-4, 1461 lb down and 66 lb up at 8-1-4, 1405 lb down and 55 lb up at 10-1-4, 1405 lb down and 48 lb up at 12-1-4, and 1405 lb down and 67 lb up at 14-1-4, and 2565 lb down and 303 lb up at 16-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss TG03 Truss Type Common Girder Qty 1 Ply 2 116 Woods at Shelborne Job Reference (optional) I35298972 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:24 2018 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-fEC66vKJGT5XU1DTwNG?4a0xxs6G1USG50QI6GyJZ4P LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-8=-60, 1-7=-20 Concentrated Loads (lb) Vert: 11=-1461(F) 9=-2565(F) 13=-1405(F) 14=-1405(F) 15=-1405(F) 16=-1405(F) 17=-1405(F) 18=-1405(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 116_WOODS_AT_SHELBOR~E Truss TG04 Truss Type COMMON GIRDER Qty 1 Ply 2 116 Woods at Shelborne Job Reference (optional) I35298973 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:25 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-7RmVJFKx1nDO5BogU5nEcoY4XGahm09QKgAsfiyJZ4O Scale = 1:25.0 1 2 3 4 5 6 7 10 9 819 20 21 22 8x8 3x6 4x6 8x8 3x6 8x8 3x4 2x4 3x4 2x4 3-5-8 3-5-8 6-7-8 3-2-0 9-9-8 3-2-0 13-3-0 3-5-8 3-5-8 3-5-8 6-7-8 3-2-0 9-9-8 3-2-0 13-3-0 3-5-8 0-10-03-7-20-10-05.00 12 Plate Offsets (X,Y)-- [1:0-1-4,0-2-8], [3:0-1-8,0-1-8], [5:0-1-8,0-1-8], [7:0-0-15,0-1-13], [9:0-4-0,0-4-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.65 0.48 0.53 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.18 0.03 (loc) 8-9 8-9 7 l/defl >999 >894 n/a L/d 240 180 n/a PLATES MT20 Weight: 126 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 4-9: 2x4 SPF No.2 SLIDER Left 2x4 SPF-S Stud 1-6-0, Right 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-9 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=5492/0-3-8, 7=5296/0-3-8 Max Horz 1=-26(LC 14) Max Uplift 1=-318(LC 5), 7=-309(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-7321/440, 3-4=-6102/376, 4-5=-6102/376, 5-7=-7259/437 BOT CHORD 1-10=-397/6662, 9-10=-397/6662, 8-9=-368/6598, 7-8=-368/6598 WEBS 4-9=-232/4320, 5-9=-1163/112, 5-8=-47/1160, 3-9=-1237/116, 3-10=-49/1199 NOTES-(9-10) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=318, 7=309. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1395 lb down and 79 lb up at 0-4-12, 1389 lb down and 83 lb up at 2-4-12, 1389 lb down and 83 lb up at 4-4-12, 1389 lb down and 83 lb up at 6-4-12, 1389 lb down and 83 lb up at 8-4-12, and 1389 lb down and 83 lb up at 10-4-12, and 1390 lb down and 82 lb up at 12-4-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss TG04 Truss Type COMMON GIRDER Qty 1 Ply 2 116 Woods at Shelborne Job Reference (optional) I35298973 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:25 2018 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-7RmVJFKx1nDO5BogU5nEcoY4XGahm09QKgAsfiyJZ4O LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-7=-60, 11-15=-20 Concentrated Loads (lb) Vert: 9=-1389(F) 13=-1395(F) 17=-1390(F) 19=-1389(F) 20=-1389(F) 21=-1389(F) 22=-1389(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 116_WOODS_AT_SHELBOR~E Truss TG05 Truss Type Flat Girder Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298974 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:26 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-bdKtXaLZo4LFjLNs1oIT9?59QguAVMYZYKvPB8yJZ4N Scale = 1:61.2 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 463x6 5x12 4x8 3x6 4x10 6x18 MT18HS8x16 2x4 4x8 2x4 2x4 5x12 2x4 6x16 4x8 5x10 MT18HS 7-2-15 7-2-15 14-4-10 7-1-11 21-6-6 7-1-11 28-8-1 7-1-11 35-11-0 7-2-15 7-2-15 7-2-15 14-4-10 7-1-11 21-6-6 7-1-11 28-8-1 7-1-11 35-11-0 7-2-15 3-2-15Plate Offsets (X,Y)-- [1:Edge,0-2-4], [3:0-2-12,0-2-0], [11:0-4-0,0-2-8], [15:0-6-8,0-4-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.96 0.59 0.97 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.45 -1.14 0.18 (loc) 11-13 11-13 9 l/defl >958 >374 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 215 lb FT = 20% GRIP 169/123 244/190 LUMBER- TOP CHORD 2x6 SP 2400F 2.0E *Except* 1-4: 2x6 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF 2100F 1.8E *Except* 1-16,8-9: 2x4 SPF No.2, 2-15,3-13,5-11,7-10: 2x4 SPF-S Stud BRACING- TOP CHORD 2-0-0 oc purlins (2-0-12 max.): 1-8, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-15, 7-9 REACTIONS.(lb/size) 16=2582/Mechanical, 9=2585/Mechanical Max Horz 16=81(LC 4) Max Uplift 16=-290(LC 3), 9=-291(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-16=-2435/341, 1-2=-5525/637, 2-3=-5525/637, 3-5=-8193/936, 5-7=-8193/936, 8-9=-302/102 BOT CHORD 13-15=-960/8219, 11-13=-960/8219, 10-11=-647/5547, 9-10=-647/5547 WEBS 1-15=-655/5828, 2-15=-794/305, 3-15=-2892/334, 3-13=0/516, 5-11=-726/272, 7-11=-323/2839, 7-10=0/548, 7-9=-5863/666 NOTES-(11-12) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 16=290, 9=291. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 91 lb down and 58 lb up at 1-11-12, 91 lb down and 58 lb up at 3-11-12, 91 lb down and 58 lb up at 5-11-12, 91 lb down and 58 lb up at 7-11-12, 91 lb down and 58 lb up at 9-11-12, 91 lb down and 58 lb up at 11-11-12, 91 lb down and 58 lb up at 13-11-12, 91 lb down and 58 lb up at 15-11-12, 91 lb down and 58 lb up at 17-11-12, 91 lb down and 58 lb up at 19-11-12, 91 lb down and 58 lb up at 21-11-12, 91 lb down and 58 lb up at 23-11-12, 91 lb down and 58 lb up at 25-11-12, 91 lb down and 58 lb up at 27-11-12, 91 lb down and 58 lb up at 29-11-12, and 91 lb down and 58 lb up at 31-11-12, and 91 lb down and 58 lb up at 33-11-12 on top chord, and 66 lb down at 1-11-12, 66 lb down at 3-11-12, 66 lb down at 5-11-12, 66 lb down at 7-11-12, 66 lb down at 9-11-12, 66 lb down at 11-11-12, 66 lb down at 13-11-12, 66 lb down at 15-11-12, 66 lb down at 17-11-12, 66 lb down at 19-11-12, 66 lb down at 21-11-12, 66 lb down at 23-11-12, 66 lb down at 25-11-12, 66 lb down at 27-11-12, 66 lb down at 29-11-12, and 66 lb down at 31-11-12, and 66 lb down at 33-11-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Continued on page 2 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss TG05 Truss Type Flat Girder Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298974 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:26 2018 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-bdKtXaLZo4LFjLNs1oIT9?59QguAVMYZYKvPB8yJZ4N 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-8=-60, 9-16=-20 Concentrated Loads (lb) Vert: 4=-91(F) 14=-45(F) 6=-91(F) 12=-45(F) 17=-91(F) 18=-91(F) 19=-91(F) 20=-91(F) 21=-91(F) 22=-91(F) 23=-91(F) 24=-91(F) 25=-91(F) 26=-91(F) 27=-91(F) 28=-91(F) 29=-91(F) 30=-91(F) 31=-91(F) 32=-45(F) 33=-45(F) 34=-45(F) 35=-45(F) 36=-45(F) 37=-45(F) 38=-45(F) 39=-45(F) 40=-45(F) 41=-45(F) 42=-45(F) 43=-45(F) 44=-45(F) 45=-45(F) 46=-45(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 116_WOODS_AT_SHELBOR~E Truss V01 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298975 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:27 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-3puFkwMBZOT6LVy2bWpiiDdVD4DbE2wjn_fzjbyJZ4M Scale = 1:12.4 1 2 3 2x4 2x4 2x4 6-7-11 6-7-11 3-3-13 3-3-13 6-7-11 3-3-13 0-0-41-4-100-0-45.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.26 0.64 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=221/6-7-11, 3=221/6-7-11 Max Horz 1=-11(LC 7) Max Uplift 1=-11(LC 6), 3=-11(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V02 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298976 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:27 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-3puFkwMBZOT6LVy2bWpiiDdWX4LLE2wjn_fzjbyJZ4M Scale = 1:8.5 1 2 3 2x4 2x4 2x4 3-5-9 3-5-9 0-0-41-1-144.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.24 0.15 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-9 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=107/3-5-9, 3=107/3-5-9 Max Horz 1=31(LC 5) Max Uplift 1=-7(LC 4), 3=-12(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V04 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298977 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:28 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-X0SdyGNqKibzyfXF9DLxEQAi0ThtzU3s0eOWF1yJZ4L Scale = 1:29.8 1 2 3 4 5 6 7 13 12 11 10 9 83x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 10-6-6 10-6-6 17-2-14 6-8-8 10-6-6 10-6-6 17-2-14 6-8-8 0-0-44-4-101-7-25.00 12 Plate Offsets (X,Y)-- [4:0-3-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.19 0.19 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 17-2-14. (lb) - Max Horz 1=47(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 11, 13, 10 except 8=-108(LC 11), 9=-130(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 8 except 11=297(LC 1), 13=366(LC 10), 10=322(LC 1), 9=311(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-13=-274/130 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 13, 10 except (jt=lb) 8=108, 9=130. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V05 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298978 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:29 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-?C0?9cOS4?jqao6RjwsAnejq0t1?iyS?FI83oTyJZ4K Scale = 1:24.9 1 2 3 4 5 9 8 7 63x4 3x6 3x8 2x4 2x4 2x4 2x4 2x4 15-2-14 15-2-14 8-6-6 8-6-6 15-2-14 6-8-8 0-0-43-6-100-9-25.00 12 Plate Offsets (X,Y)-- [1:0-1-3,Edge], [5:0-0-8,0-1-4], [5:Edge,0-2-8], [6:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.37 0.13 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-2-14. (lb) - Max Horz 1=34(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 6, 9, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 8=281(LC 1), 9=369(LC 10), 7=314(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-265/125 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6, 9, 7. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V06 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298979 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:29 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-?C0?9cOS4?jqao6RjwsAnejnvt_bixH?FI83oTyJZ4K Scale = 1:21.3 1 2 3 43x6 4x8 3x6 2x4 13-0-12 13-0-12 6-6-6 6-6-6 13-0-12 6-6-6 0-0-42-8-110-0-45.00 12 Plate Offsets (X,Y)-- [1:0-0-6,Edge], [3:0-1-6,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.56 0.35 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=203/13-0-12, 3=204/13-0-12, 4=517/13-0-12 Max Horz 1=-23(LC 7) Max Uplift 1=-23(LC 6), 3=-26(LC 7), 4=-1(LC 6) Max Grav 1=208(LC 10), 3=208(LC 11), 4=517(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-343/129 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V07 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298980 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:30 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-UOZONyO4rJrhCygdGeNPJrFyGHKGRO09TytdKwyJZ4J Scale = 1:16.6 1 2 3 4 2x4 3x4 2x4 2x4 9-0-12 9-0-12 4-6-6 4-6-6 9-0-12 4-6-6 0-0-41-10-100-0-45.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.53 0.32 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=156/9-0-12, 3=156/9-0-12, 4=323/9-0-12 Max Horz 1=-16(LC 7) Max Uplift 1=-22(LC 6), 3=-25(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V08 Truss Type Valley Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298981 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:30 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:1hUJ8lEvSVnRgCoHR7G444yJZwd-UOZONyO4rJrhCygdGeNPJrF2RHK8ROg9TytdKwyJZ4J Scale = 1:9.8 1 2 3 2x4 2x4 2x4 5-0-2 5-0-2 5-0-12 0-0-10 2-6-6 2-6-6 5-0-12 2-6-6 0-0-41-0-100-0-45.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.13 0.33 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-12 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=158/4-11-8, 3=158/4-11-8 Max Horz 1=-8(LC 7) Max Uplift 1=-8(LC 6), 3=-8(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V09 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298982 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:31 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-yb7maIPicdzXp6FpqLues3o89hgDArJIicdAsMyJZ4I Scale = 1:15.6 1 2 3 4 2x4 3x4 2x4 2x4 8-5-12 8-5-12 4-2-14 4-2-14 8-5-12 4-2-14 0-0-41-9-30-0-45.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.45 0.28 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=145/8-5-12, 3=145/8-5-12, 4=300/8-5-12 Max Horz 1=15(LC 6) Max Uplift 1=-21(LC 6), 3=-23(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V10 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298983 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:31 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-yb7maIPicdzXp6FpqLues3o90hiEAqoIicdAsMyJZ4I Scale = 1:24.3 1 2 3 4 5 9 8 7 63x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-11-6 13-11-6 8-10-10 8-10-10 13-11-6 5-0-12 0-0-43-8-71-7-25.00 12 Plate Offsets (X,Y)-- [1:0-2-15,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.40 0.15 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 13-11-6. (lb) - Max Horz 1=42(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 6, 9, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 8=292(LC 1), 9=388(LC 10), 7=333(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-275/135, 4-7=-259/126 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6, 9, 7. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V11 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298984 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:33 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-uzFW?_Ry8EDF3QPCymw6xUtXpUPCejOb9w6HxEyJZ4G Scale = 1:53.1 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 3x6 4x6 3x6 3x4 3x6 4x6 33-1-6 33-1-6 17-10-14 17-10-14 33-1-6 15-2-8 0-0-47-5-81-1-85.00 12 Plate Offsets (X,Y)-- [1:0-1-2,Edge], [36:0-1-4,0-0-0], [36:0-3-0,0-1-4], [37:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.31 0.12 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 26 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 409 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-3,23-25: 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 *Except* 37-40: 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 33-1-6. (lb) - Max Horz 1=72(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 39, 41, 42, 43, 44, 45, 46, 47, 48, 49, 35, 34, 33, 32, 31, 30, 29, 28, 27 Max Grav All reactions 250 lb or less at joint(s) 26, 1, 38, 39, 41, 42, 43, 44, 45, 46, 47, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27 except 49=330(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 39, 41, 42, 43, 44, 45, 46, 47, 48, 49, 35, 34, 33, 32, 31, 30, 29, 28, 27. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V12 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298985 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:33 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-uzFW?_Ry8EDF3QPCymw6xUtZNUMIeiMb9w6HxEyJZ4G Scale = 1:53.5 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 122122 3x6 4x6 3x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 3x4 31-1-6 31-1-6 15-10-14 15-10-14 31-1-6 15-2-8 0-0-46-7-80-3-85.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.15 0.30 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 90 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 15-18: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 31-1-6. (lb) - Max Horz 1=59(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 17, 19, 20, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 1, 11 except 16=459(LC 1), 17=418(LC 10), 19=307(LC 1), 20=322(LC 10), 14=418(LC 11), 13=308(LC 1), 12=317(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-17=-260/118, 7-14=-259/118 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 19, 20, 14, 13, 12. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V13 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298986 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:34 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-MApuCKRavYL6ga_OVURLUhQiluj9NAFlOarqThyJZ4F Scale = 1:44.6 1 2 3 4 5 6 7 13 12 11 10 9 83x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 27-9-12 27-9-12 13-10-14 13-10-14 27-9-12 13-10-14 0-0-45-9-80-0-45.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [7:0-1-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.30 0.20 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 27-9-12. (lb) - Max Horz 1=-52(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 7, 12, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=478(LC 1), 12=378(LC 10), 13=423(LC 1), 9=378(LC 11), 8=423(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-13=-305/134, 6-8=-305/134 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 12, 13, 9, 8. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V14 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298987 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:35 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-qMNGQfSDgrTzIjZb3Bza0vzvpI496eEudEbO?7yJZ4E Scale = 1:38.2 1 2 3 4 5 6 7 13 12 11 10 9 814153x4 4x6 3x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 23-9-12 23-9-12 11-10-14 11-10-14 23-9-12 11-10-14 0-0-44-11-80-0-45.00 12 Plate Offsets (X,Y)-- [11:0-1-4,0-0-0], [12:0-3-0,0-1-4], [12:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.15 0.15 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 63 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-12: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 23-9-12. (lb) - Max Horz 1=44(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 11, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=279(LC 1), 11=342(LC 10), 13=314(LC 1), 9=342(LC 11), 8=314(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-262/120, 5-9=-263/120 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11, 13, 9, 8. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V15 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298988 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:35 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-qMNGQfSDgrTzIjZb3Bza0vzsOI1m6eoudEbO?7yJZ4E Scale: 3/8"=1' 1 2 3 4 5 9 87 63x4 4x6 3x4 4x6 2x4 2x4 2x4 2x4 19-9-12 19-9-12 9-10-14 9-10-14 19-9-12 9-10-14 0-0-44-1-80-0-45.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [5:0-1-8,0-1-8], [7:0-1-4,0-0-0], [8:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.37 0.37 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 19-9-12. (lb) - Max Horz 1=-36(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 9=461(LC 10), 6=461(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-346/147, 4-6=-346/147 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 9, 6. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V16 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298989 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:36 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-IYxfd?TrR9bqwt8ndvUpZ6V1ziR0r6I1stKxYZyJZ4D Scale = 1:25.4 1 2 3 4 5 8 7 63x4 3x6 3x4 2x4 2x4 2x4 2x4 2x4 15-9-12 15-9-12 7-10-14 7-10-14 15-9-12 7-10-14 0-0-43-3-80-0-45.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.38 0.11 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-9-12. (lb) - Max Horz 1=-28(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=282(LC 1), 8=339(LC 10), 6=339(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 Job 116_WOODS_AT_SHELBOR~E Truss V17 Truss Type GABLE Qty 1 Ply 1 116 Woods at Shelborne Job Reference (optional) I35298990 8.220 s Oct 6 2018 MiTek Industries, Inc. Tue Nov 13 15:17:37 2018 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:dP6q1w9rTxnUbh9yLknLczzZMnA-mlV1rLUTCTjhX1jzBc?26K2C56imaZlB4X4U40yJZ4C Scale = 1:19.2 1 2 3 4 5 3x8 3x6 3x8 2x4 4x6 11-9-12 11-9-12 5-6-14 5-6-14 6-2-14 0-8-0 11-9-12 5-6-14 0-0-42-3-140-0-42-3-145.00 12 Plate Offsets (X,Y)-- [1:0-7-3,Edge], [2:0-4-4,0-1-12], [3:0-3-8,0-1-10], [4:0-1-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.36 0.33 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.01 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 2-3. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size) 1=266/11-9-12, 4=246/11-9-12, 5=313/11-9-12 Max Horz 1=19(LC 6) Max Uplift 1=-48(LC 6), 4=-32(LC 6), 5=-6(LC 7) Max Grav 1=306(LC 10), 4=246(LC 1), 5=378(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-390/114, 2-3=-300/130, 3-4=-344/112 BOT CHORD 1-5=-66/300, 4-5=-66/300 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. November 13,2018 edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 8 7 6 54321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015WEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 8 7 6 54321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System General Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.