Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Plans
FIRST FLOOR PLAN SCALE: 1/8" = 1'-0" NORTH _QFrnNn 1:1 nnR Di AN CONSTRUCTION NOTES 1. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. 2. SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION 3. ALL NEW DOORS TO BE HINGED 6" AWAY FROM WALL, UNLESS 4. PROVIDE CONCEALED, FIRE RATED, WALL BLOCKING AS REQUIRED WHERE NEW SHELVING, PLUMBING AND CASEWORK ARE NOTED. 5. ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION 6. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR UNLESS NOTED OTHERWISE TO MEET ADA CODE REGULATIONS. 7. ALL NEW WORKSURFACES TO RECEIVE 2-1/2" GROMMETS. NEW GROMMET LOCATIONS TO BE VERIFIED WITH TENANT IN FIELD AND WITH RESPECT TO NEW ELECTRICAL LAYOUT. GROMMET COLOR TO BE IVORY. 8. ALL WALLS SCHEDULED TO REMAIN I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. 9. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. 10. ALL NEW TRACK AND TRIM AT WALL/CEILING CONDITIONS SHALL MATCH EXISTING COLOR AND MATERIAL TO PROVIDE CONTINUOUS/CONSISTENT APPEARANCE THROUGHOUT CEILING. 11. BUILDING OWNER AND/OR G.C. TO PROVIDE MINIBLINDS AT ALL PERIMETER WINDOWS. EXISTING MINIBLINDS TO BE RELOCATED ARE TO BE STORED DURING CONSTRUCTION PHASE, THEN CLEANED AND REINSTALL UPON COMPLETION OF CONSTRUCTION. 12. ALL NEW FIRE EXTINGUISHER CABINETS TO BE PAINTED TO MATCH ADJACENT WALL FINISH. LIFESAFETY CONTRACTOR TO VERIFY NEED FOR ANY ADDITIONAL FIRE EXTINGUISHER CABINET LOCATIONS. IF ADDITIONAL FIRE EXTINGUISHER CABINETS ARE REQUIRED, LOCATIONS MUST BE SUBMITTED TO CSO INTERIORS FOR LOCATION REVIEW FOR AESTHETICS PURPOSES ONLY. 13. RADIUS ALL OUTSIDE CORNERS OF COUNTER TOPS. SIZE OF RADIUS TO BE VERIFIED WITH DESIGNER TO DETERMINE SIZE OF EACH RADIUSED CORNER CONSTRUCTION PLAN NOTES 8 ALIGN FINISHED FACES. FP2 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 1/A603. FP3 NEW SEMI RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION. PAINT TO MATCH ADJACENT WALL SURFACE. FIRE EXTINGUISHER CABINET TO MATCH BLDG. STANDARD, UNLESS �a PROVIDE 1/4- COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE MAKER, REFRIGERATOR AND COFFEEMAKER. VERIFY EXACT LOCATION OF ALL APPLIANCES REQUIRING A WATER SOURCE. SEE SERIES A200 AND A600 SHEETS FOR FURTHER INFORMATION. ROOMS 209, 215, 244 & 245 TO HAVE WATER UNE FOR COFFEE MAKER & ICE MAKER. IN ADDITION, ROOM 244 TO HAVE WATER LINE FOR REFRIGERATOR. FPS PROVIDE ADA ACCESSIBLE COAT ROD AND SHELF; REFERENCE DETAIL 6/A601. �s PROVIDE STANDARD HEIGHT COAT ROD AND SHELF; REFERENCE DETAIL 6/A601 --r'41 J-0,4s6a/76a� COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. VERIFY ELECTRICAL REQ. WITH MANUF. MANUAL. O VENDING MACHINES PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR VENDING MACHINE. VERIFY ELECTRICAL REQ. WITH MANUF. MANUAL. O (XX} 12"dp. 3/4" PAINTED PLYWOOD SHELVES ON HEAVY DUTY KV 187-72" STANDARDS & KV 87-12" BRACKETS. PROVIDE ADDITIONAL BLOCKING AS REQ'D PROVIDE ADDITIONAL BLOCKING AS REQUIRED. COLOR TO BE P1. �o UNDERCOUNTER GARBAGE DISPOSAL TO BE PROV. AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR GARBAGE DISPOSAL. VERIY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. �» REFRIGERATOR PROVIDED AND INSTALLED BY G.C. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQ. WITH MANUF. MANUAL. REFRIGERATOR AS MANUF. BY G.E., SPECIFICATION: XXXXX, COLOR: WHITE. Pi G.C. TO PROVIDE AND INSTALL DISHWASHER. SERVICE TO CONFIRM UNIT IS IN WORKING ORDER AND IS NOT LEAKING BEFORE TURNING UNIT OVER TO TENANT. DISHWASHER AS MANUF. BY G.E.; SPECIFICATION: XXXXX, COLOR: WHITE. is PROVIDE 3/4" x 4' x 8' FIRE RETARDANT PLYWOOD PHONE BOARD. PHONE BD. PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH. �4 WALL MOUNTED TELEVISION;TO BE MOUNTED 8'-6" AFF. �s PROVIDE BLOCKING IN WALL AS NECESSARY. �s EXISTING CONSTRUCTION TO BE REMOVED. WALL LEGEND ALL WALL TO BE W1 UNLESS NOTED OTHERWISE. FRAME HARDWARE REMARKS DASHED LINES INDICATE EXISTING CONSTRUCTION — TO BE DEMOLISHED. EXISTING PARTITION TO REMAIN W1= NEW WALL CONSTRUCTION TO BE: Z W Z 3-5/8" METAL STUDS ® 16" O.C. WITH 5/8' O Q O YCL GYPSUM BOARD EACH SIDE. WALLS TO Z m W2 dMLLI EXTEND TO UNDERSIDE OF CEILING UNE. W2= NEW WALL CONSTRUCTION TO BE: N p�N� tJJCU 3-5/8" METAL STUDS 0 16" O.C. WITH 5/8" O Z GYPSUM BOARD EACH SIDE. WALLS TO = :3= EXTEND TO STRUCTURAL DECK. til if1111 W _J (n a U C c=i PROVIDE 2 1/2" SOUND INSULATION IN 103 MAIL CENTER HORIZONTAL SURFACE ABOVE CEILING AND FH 1 3/41 INSIDE WALL. INSULATION TO EXTEND D/F-1 WILSON D/F-1 2'-0" IN BOTH DIRECTIONS FROM CENTER— 200 RECEPTION LINE OF WALL. FH W3= NEW WALL CONSTRUCTION TO BE: I w WILSON D/F-3 (2) 3-5/8" METAL STUDS 0 16" O.C. WITH 5/8" 201 LIBRARY/CONF. GYPSUM BOARD ONE SIDE. WALLS TO HAVE 6" PLUMBING CHASE FH 1 3/4" BETWEEN STUDS. WALL TO EXTEND TO STRUCTURAL DECK. — WILSON D/F-1 W4= DEMOUNTABLE WALL AS MANUF. BY. XXXXXXXX. (� 3'-0" FH MANUFACTURER TO SUPPLY LETTER TO TENANT DESCRIBING WD D/F-1 WILSON D/F-1 ACTUAL STC FIELD RATINGS AND EXPECTED PERFORMANCE 203 TRAINING B 3'-0" OF PANEL. 1 3/4 WD W5= NEW WALL CONSTRUCTION TO BE: I 204 TRAINING A 3-5/8" METAL STUDS 0 16" O.C. WITH 5/8" Cn 1 3/4" GYPSUM BOARD EACH SIDE. WALLS TO D/F-1 .WILSON D/F-1 EXTEND TO 7'-0" AFF. = DENOTES AREA NOT IN CONTRACT = DENOTES NEW MILLWORK = NEW DOORS, NUMBERS REFERENCE DOOR SCHEDULE = EXISTING DOOR TO REMAIN DOOR SCHEDULE NOTES 1. ALL DOORS TO BE STAINED TO MATCH BUILDING STANDARD. 2. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD. 3. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. ALL DOORS TO BE FULL HEIGHT. 4. COORDINATE KEYING LOCKSETS WITH TENANT. 5. ALL NEW KD ALUMINUM DOOR FRAMES SHALL MATCH BUILDING STANDARD. DOOR FRAMES SHALL BE PREPPED AND PAINTED SEMI—GLOSS TO MATCH ADJACENT WALL FINISH. 6. ALL OFFICE DOORS TO HAVE LOCKS. DOOR/FRAME ELEVATIONS D 0 0 R S C H E D U L E Drawn By Chwked B DOOR FRAME HARDWARE REMARKS SIZE J c Nffi0C Z W Z Q O Q O YCL Z m W2 dMLLI p�N� tJJCU O Z = :3= til if1111 W _J (n a U C c=i 103 MAIL CENTER (2)3'-0 FH 1 3/41 WD D/F-1 WILSON D/F-1 200 RECEPTION 2)3'-0 FH 1 3/44 WD D/F-3 WILSON D/F-3 201 LIBRARY/CONF. 3'-O" FH 1 3/4" WD D/F-1 WILSON D/F-1 202 DIRECTOR 3'-0" FH 1 3/4 WD D/F-1 WILSON D/F-1 203 TRAINING B 3'-0" FH 1 3/4 WD D/F-1 WILSON D/F-1 204 TRAINING A 3'-0" FH 1 3/4" WD D/F-1 .WILSON D/F-1 205 TRAINING C 3'-0" FH 1 3/4 WD D/F-1 WILSON D/F-1 206 I.T. 3'-0" FH 1 3/4 WD D/F-1 WILSON D/F-1 207 STORAGE 3'-0" FH 1 3/4 WD D/F-1 WILSON D/F-1 208 SERVER 3'-0" j FH 1 3/4 WD D/F-1 WILSON D/F-1 209 COATS (2)3'-0 FH 1 3/4'.WD D/F-1 WILSON D/F-1 210 COATS (2)3'-0 FH 1 3/4" WD D/F-1 WILSON D/F-1 211 STORAGE 3'-0" FH 1 3/4 WD D/F-1 WILSON D/F-1 212 DIRECTOR 3'-0" FH 1 3/4 WD D/F-1 WILSON D/F-1 213 ENCLAVE 3'-0' FH 1 3/4 WD D/F-1 WILSON D/F-1 214 STORAGE 3'-0' FH i 3/4 WD D/F-1 WILSON D/F-1 215 CONFERENCE 3'-0" FH 1 3/4' WD D/F-1 WILSON D/F-1 216 EXEC. OFFICE 3'-0' FH 1 3/4 WD D/F-1 WILSON D/F-1 217A CONFERENCE 3'-0" FH 1 3/4 WD I D/F-2 WILSON D/F-2 POCKET DOOR 217B CONFERENCE 3'-0' FH 1 3/4 WD D/F-2 WILSON D/F-2 SEE NOTE #5 217C CONFERENCE 3'-0" FH 1 3/4 WD D/F-2 WILSON D/F-2 SEE NOTE #5 218 STOKE 3'-0" FH 1 3/4' WD D/F-1 WILSON D/F-1 219 CONFERENCE 3'-0" FH 1 3/4 WD ID/F-1 WILSON D/F-1 220 SLAVE 3'-0" FH 1 3/4 WD D/F-2 WILSON D/F-2 POCKET DOOR 221 ENCLAVE 3'-0" FH 1 3/4 WD D/F-2 WILSON D/F-2 POCKET DOOR 222 DIRECTOR 3'-0" FH 1 3/4' WD D/F-1 WILSON D/F- 11 223 DIRECTOR 3'-0" FH 1 3/4' WD D/F-1 WILSON D/F-1, 224 DIRECTOR 3'-O" FH 1 3/4' WD D/F-1 WILSON D/F-1 225 LIVING RM. 3'-0" FH 1 3/4 WD D/F-1 WILSON D/F-1 L - yeas - s 226 DEMO 3'-0" FH 1 3/4 WD D/F_1 WILSON D/F-1 " 227 ENCLAVE 3'-0" FH 1 3/4 WD D/F-1 WILSON D/� 229 CORRIDOR 3'-0" FH 1 3/4 WD D/F-1 WILSON D 1:�, 230 BREAKROOM 3'-0' FH 1 3/4" WD D/F-1 F-1`' r 231 OFFICE 3'-0" FH 1 31el WD D/F_I W F � t 232 OFFICE 3'-0" FH 1 3/4 WD D/F-1 WILSON -1 r 233 OFFICE 3'-0" FH 1 3/4" WD 1D/F-1 WILSON D11VA, 234 STORAGE 3'-0" FH 1 3/4' WD D/F-1 WILSON DA/F f 236 OFFICE 3'-0" FH 1 3/4" WD D/F-1 WILSON D 237 OFFICE 3'-0" FH 1 3/4' WD D/F-1 WILSON D/F-1 "� c 238 OFFICE 3'-0" FH 1 3/4" WD D/F-1 WILSON D/F-1/ 239 ENCLAVE 3'-0" FH 1 3/4' WD D/F-1 WILSON D/F-1 �,r►„ r 240 OFFICE 3'-0" FH 1 3/4 WD D/F-1 WILSON D/F-1 241 OFFICE 3'-0" FH 1 3/4" WD D/F-1 WILSON D/F-1r�£ " " 242 OFFICE 3'-0" FH 1 3/4 WD D/F-1 WILSON D/F-1' 243 COATS 3'-0" FH 1 3/4" WD D/F-1 WILSON D/F-1 BREAKROOM S-0" FH 1 31el WD DA -1 WILSON D/F-1 C S Architecture Engineering Interiore Landscape Architecture Land Surveying Corporate Office 280 Ent Nth Street Suft 200 kwwup^ Irwena 40240 517.848.7800 FAX 317.574.0957 I ®Copyright 2002 Project DEBORAH WOOD 8 ASSOCIATES LAKESIDE CORPORATE CENTER 630 WEST CARMEI CARMEL, INDIANA 46032 SCOP DrawIn6w. These drawings indicate the general scope of the projei in terms of architectural design concept, the dimensions i the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or describe the trade contractors shall furnish all items required for th proper execution and completion of the work. 11 Drawk* Tft ONSTRUCTIO1 f6AN- lmmWe Drawn By Chwked B 10/30/02 BB LH 1 CWNW By: 0R� . sv� ���� AR 00380145 a TATE QEF A201 Project *M*W.. 22286C FIRST FLOOR PLAN SCALE: 1/8" = 1'-0" SECOND FLOOR PLAN SCALE: 1/801 = V-0" 9 xoxnH REFLECTED CEILING PLAN NOTES 1. ALL CAN LIGHTS TO BE CENTERED ON CEILING TILE UNLESS OTHERWISE NOTED. PENDANT FIXTURE HOUSING IN RECEPTION AREA NOT CENTERED. 2. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR AESTHETIC REVIEW ONLY. 3. ALL ROOM WALLS TO UNDERSIDE OF SUSPENDED CEILING, TYPICAL UNLESS OTHERWISE NOTED. SEE A200 SERIES DRAWINGS FOR FURTHER WALL TYPE INFORMATION. 4. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES, PROJECTION SCREENS OR PARTITIONS HAVE BEEN REMOVED. CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT CONDITION AS TO NOT SHOW LINE OF DEMOLITION. 5. MECHANICAL AND ELECTRICAL IS DESIGN—BUILD. DESIGN—BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN—BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. 6. CEILING HEIGHT IS 8'-11" A.F.F. UNLESS OTHERWISE NOTED. 7. LOCATE NEW SMOKE DETECTORS BASED ON NEW LIGHT FIXTURE LAYOUT. INFORM DESIGNER AND DESIGN BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. 8. IN LOCATIONS OF (2) TWO OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. 9. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. 10. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. 11. PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS. 12. SUPPLY/INSTALL NEW VOICE/DATA CABLE TRAY AS DIRECTED ON DATA/CABLING DRAWINGS. 13. INSTALL ALL THERMOSTATES AT +72"A.F.F. TO CLEAR SYSTEMS FURNITURE PANELS. REFLECTED CEILING PLAN NOTES 8 PROVIDE POWER AND SWITCHING IN CEILING FOR MOTORIZED PROJECTION SCREEN MOTORIZED PROJECTION SCREEN AND HOUSING TO BE PROVIDED BY THE AUDIO—VISUAL CONTRACTOR. HOUSING TO BE INSTALLED BY CONTRACTOR DURING CONSTRUCTION. CP2 PROVIDE POWER, SWITCHING AND NETWORK ADAPTER IN CEILING FOR RECESSED PROJECTOR. RECESSED PROJECTOR LIFT TO BE PROVIDED BY THE AUDIO—VISUAL CONTRACTOR AND INSTALLED BY CONTRACTOR DURING CONSTRUCTION. REFLECTED CEILING LEGEND NEW WALL WASHER 6- APATURE/WHITE CONE AND WHITE TRIM RING NEW DOWNLIGHT FIXTURE INCONDESCENT 15OW WHITE CONE AND WHITE TRIM RING NSW DOWNLIGHT FIXTURE—FLOURESCENT 32 WATT TRIPLE TUBE 8 CONE WHITE CONE AND WHITE TRIM RING NF,�W DOWNLIGHT FIXTURE—FLOURESCENT 32 WATT TRIPLE TUBE 8 CONE WHITE CONE AND WHITE TRIM RING NEW 2' X 4' FLOURESCENT FIXTURE, SEE BUILDING STD FOR SPECIFICATION. E NEW 2' X 2' FLOURESCENT FIXTURE, LITHONIA INDIRECT AVANTE F NEW CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION DUAL—LITE, TO MATCH BUILDING STANDARD NEW 2 X 2 LAY—IN GRID SUSPENSION SYSTEM, SEE BUILDING STD FOR CEILING SUSPENSION SYSTEM AND CEILING TILE SPECIFICATION. NEW 2 X 4 LAY—IN GRID SUSPENSION SYSTEM, SEE BUILDING STD FOR CEILING SUSPENSION SYSTEM AND CEILING TILE SPECIFICATION. NEW 2 X 2 LAY—IN GRID SUSPENSION SYSTEM, SEE ARMSTRONG FOR CEILING SUSPENSION SYSTEM AND CEILING TILE SPECIFICATION—RECEPTION AREA NEW 2 X 2 LAY—IN GRID SUSPENSION SYSTEM, SEE ARMSTRONG FOR CEILING SUSPENSION SYSTEM AND CEILING TILE SPECIFICATION—RECEPTION AREA NL NEW EMERGENCY 24 HOUR BALLAST. WALL SCONCE—LEUCOS LIGHTING / VENYS S15—S20 GLOSS AMBER PENDANT FIXTURE/DESIGN GALLERY Owner: !i CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 98th Street Suite 200 Indanapoli% Indiana 48240 3V.848.7800 FAX 317.574.0957 ®Copyright 2002 Contractor/Consultant: Project: DEBORAH WOOD 8 ASSOCIATES LAKESIDE CORPORATE CENTER 630 WEST CARMEL CARNAL, INDIANA 46032 Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanicol and electrical systems. The drawings do not necesaarily indicate or describe all work required for full performance and completion of the requirements of theContract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. 11 Drawing Title: REFLECTED CEILING PLAN Revisions: Issue Date Drawn By Checked By 10/30/02 DN LH Certilled By: 11 �1 M0 9 AR 00880145 STATE OF "VI) AN =J —1f r il Drawing Number: A202 11 Project Number: 11 22286C Owner: 1/2"HW 1 /2"CW, & 1-1/4"V V—O" PLASTIC LAMINATE UPPER CABINET. -2" 5EE ELEVATION FOR FINfSH. PLASTIC LAMINATE UPPER CABINET. • FINISH PI-3. CONNECT TO � (2) ADJUSTABLE SHELVES ON PIN -IN-HOLE SUPPORT. BUILDING MAINS N ADJUSTABLE SHELF ON 4" WHITE METAL PULLS PIN -IN-HOLE SUPPORT. I iV 4" WHITE METAL PULLS SINK 2'W4" BACKSPLASH IN COFFEE/BREAK AREAS. SCRIBE TO WALL IN ZZ COPY/WORK AREAS. 3/4" PLASTIC LAMINATE COUNTER —' WITH 1 1/2" LIP. SEE ELEVATION 2 -6" 3/4" PLASTIC LAMINATE COUNTER TO BUILDING FOR FINISH. WITH 1 1/2" LIP. FINISH PI -4. AN DRAIN PLASTIC LAMINATE BASE CABINET W/6" DRAWER. SEE ELEVATION TYPICAL PLUMBING COFFEE/FAX/PRINT RM. 209 COFFEE/COPY RM. 245 FOR FINISH. riT�ELEVATION E L E VA T I O N o 4" WHITE METAL PULLS 3/4" PLASTIC LAMINATE SUPPORT Architecture 15 ISOMETRIC" i ® 4'-0" MIN. O.C. FINISH PI -3. CSO A6O1 SCALE: NOT TO SCALE A601 SCALE: 1/2" = 1'-O" A601 SCALE: 3/4 = 1 -0 N Engineering N Interiors Landscape Architecture Land Surveying PLASTIC LAMINATE BASE TO MATCH Corporate Office CABINET 200 East 96th Street { SuRe 200 Indanspolis, Indiana 46240 317.848.7800 COFFEE AREA COUNTERTOP FAX 317.574.0957 EN �Copyrighi 2002 --- -- 3 TYPICAL SECTION TYPICAL SECTION I Contractor/Consultant A601 SCALE: 1" = 1'-0" A601 SCALE: 1" = 1'-0" Ii i a( i f -o" 1-0" PLASTIC LAMINATE UPPER CABINET. PLASTIC LAMINATE UPPER CABINET. SEE ELEVATION FOR FINISH. SEE ELEVATION FOR FINISH. I ! I I I I I (2) ADJUSTABLE SHELVES ON PIN -IN-HOLE SUPPORT. (2) ADJUSTABLE SHELVES ON ,i PIN -IN-HOLE SUPPORT. ' C14 i 4 4" WHITE METAL PULLS --~ 4" WHITE METAL PULLS Project I tf DEBORAH WOOD & BREAK ROOM 244 COFFEE/COPY RM. 215 ri2 ELEVATION $ ELEVATION " " ASSOCIATES 4 BACKSPLASH IN COFFEE/BREAK 4 BACKSPLASH IN COFFEE/BREAK A601 SCALE: 1 j2" = 1'-0" A601 SCALE: 3/4" = 1'-0" AREAS. SCRIBE TO WALL IN 1 AREAS. SCRIBE TO WALL IN I i COPY/WORK AREAS. 2'-0" CO"ORK AREAS. `—"-` ; 3/4" PLASTIC LAMINATE COUNTER { 3/4" PLASTIC LAMINATE COUNTER �� WITH 1 1/2" LIP. SEE ELEVATION } WITH 1 1/2" LIP. SEE ELEVATION FOR FINISH. LAKESIDE FOR FINISH. CORPORATE i PLASTIC LAMINATE BASE CABINET — PLASTIC LAMINATE BASE CABINET CENTER W/6" DRAWER. SEE ELEVATION W/6" DRAWER. SEE ELEVATION 830 WEST CARMEL I FOR FINISH. FOR FINISH. CARMEL, INDIANA CD 4" WHITE METAL PULLS o 4" WHITE METAL PULLS 46032 fI I V f ADJUSTABLE SHELF ON I I PIN -IN-HOLE SUPPORT. Scope Drawings: ' These drawings indicate the general scope of the project • in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type PLASTIC LAMINATE BASE TO MATCH PLASTIC LAMINATE BASE TO MATCH of structural, mechanical and electrical systems. - A CABINET PLA TIC The drawrn9e da not necessarily indicate or describe all work required for full performance and completion of the IN requirements of the Contract. 3"FN 3" On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. ADA SINK CABINETRY Drawing Title: ICE 4 TYPICAL SECTION 2 TYPICAL SECTION A601 SCALE: 1" = 1'-0" A601 SCALE: 1" = 1'-0" ELEVATIONS/ i DETAILS COFFEE/COPY RM. 215 BREAK ROOM 244 9 ELEVATION 13 ELEVATION A601 SCALE: 3/4" = 1'-0" �._6.. Revisions: A601 SCALE: 1/2" = 1'-0" 01 3/4" HARDWOOD PLYWOOD SHELF PAINTED P2. 2'-6" _ BLOCKING AS REQUIRED 3/4" HARDWOOD TRIM, SINK AND HARDWARE ABOVE PAINTED P2. RETRACTABLE HAEFELE 3/4"D HARDWOOD END SUPPORT. - HARDWARE PAINTED P2 (TYP. EACH END) INDICATES DOOR IN RETRACTED POSITION 1-1/4" IF ADJACENT CABINET dia. CHROME ROD �� Issue Date Drawn By Checked By I�` ' j� 3:RECESSED BASE LINE BELOW 10/30/02 DN LH W NOTE: WHERE SPAN EXCEEDS N C " ARROW INDICATES DIRECTION I 4 -0 A CENTER SUPPORT I CABINET BRACKET IS TO BE USED CertNield By: OF MOVEMENT BY RECTRACTABLE ��� o — -- — — q (� AR 00880145 1 NOTE: -�TATF OF SINK PIPES BELOW ARE TO BEx'\ "0 b I A 11� WRAPPED FOR COMPLIANCE WITHi��� ADA GUIDELINES. I f Drawing Number: ADA SINK A601 COPY/FAX RM. 235 COAT ROD & SHELFK`5-TYPICAL PLAN SECTION BREAK ROOM 2 44Aho 1 SCALE: NOT TO SCALE 14 ELEVATION ri-o"A� ELEVATION 6 SECTION Project Number: A601 SCALE: 1/2" = 1'-0" A601 SCALE: 3/4" = 1'-0" A601 SCALE: 1 1/2" = l'-0" 22286C EXEC. EXEC. STORGE OFFICE ASSISTANT 214 2166 216A C3 B1 C3 B1 a O P1 O C4 gl W2 00o P1 O CONFERENCE p7 217 C4 B1 W2 OPEN OFFICE 250 DIRECTOR 222 eS 8 DIRECTOR 223 i C3 B1 P1 i i O DIRECTOR 212 P3 ENCLAVE 213 eacm COFFEE/COPY/PRINT/FAX 215 ALL P7 SIDES C3 B1 P1 O STORAGE 218 C3 B1 P1 P4 ONFERENCE 219 C3 61 P1 m C7 r- FN2 246 C3 B1 P1 OPEN OFFICE 249 STORAGE 248 VVD 8CPi DIRECTOR 202 ON P1 COLUMN Q IZ FIRST FLOOFJ PLAN SCALE: 1/8" = V-0" NORTH OPEN OFFICE 246 DIRECTOR 224 SECOND FLOOR PLAN SCALE: Oil FINISH PLAN NOTES NORTH 1. ALL DOORS TO BE FINISHED XXX, SEE SPECIFICATONS BELOW 2. ALL DOOR FRAMES TO BE FINISHED XXX, SEE SPECIFICATONS BELOW 3. ALL WOOD TRIM TO BE FINISHED XXX, SEE SPECIFICATION BELOW 4. ALL DRYWALL BULKHEAD FINISHES ARE CALLED OUT ON REFLECTED CEILING PLAN, SEE A202 SERIES SHEETS FOR FURTHER INFORMATION. 5. ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO AS CLOSE AS POSSIBLE TO THIER ORIGINAL CONDITION. 6. PAINT EXISTING FIRE EXTINGUISHER CABINETS AND METAL HVAC GRILLES TO MATCH ADJACENT WALL FINISH. 7. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED TO PROVIDE A SMOOTH TRANSITION FROM FINISH TO FINISH 8. G.C. TO SUBMIT SEAMING DIAGRAMS, OF ALL NEW CARPETS IN PROJECT SCOPE, FOR REVIEW AND APPROVAL BY ARHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH FLOORING INSTALLATION. 9. G.C. TO PROVIDE ZINC AND/OR BRASS, TYPE TO BE DETERMINED BY DESIGNER, TRANSITION STRIP WHERE CARPET AND TERRAllO AND/OR TERRAllO AND TERRAllO FINISHES MEET. 10. SEE FINISH SHEET, SERIES A800 DRAWINGS, FOR FURTHER INFORMATION ON CORNER GUARD LOCATIONS. 11. PAINT FIRE RATED PLYWOOD FIRE RATED PHONE BOARD/S TO MATCH ADJACENT WALL FINISH. 12. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK, TO ARCHITECT AND/OR DESIGNER FOR REVIEW AND APPROVAL, BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. 13, PROVIDE MINIBLINDS TO MATCH BUILDING STANDARD MINIBLINDS , AT ALL PERIMETER WINDOWS, TO BE PROVIDED BY BUILDING OWNER UNLESS SPECIFIED OTHERWISE. 14. SUPPLY INSTALL FULL HEIGHT OR PARTIAL HEIGHT, CLEAR OR COLOR CORNER GUARDS. REFER TO FINISH PLAN FOR LOCATIONS. 15. BASE IN RESTROOMS MUST BE MIN. 5" HEIGHT TO MEET BOARD OF HEALTH CODE. ALTERNATES ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF ARCHITECT/DESIGNER. SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. FINISH PLAN NOTES 9 ALIGN FINISHES 9 END ACCENT PAINT COLOR ON INSIDE CORNER. 9 FLOOR FINISH TO ALIGN WITH BULKHEAD FN4 SEE RECEPTION DESK DETAILS FOR FINISHES ON DESK. COATS 210 S Ei SERVER STORAGE 208 207 VCT1 a 8'_1 VCT1� I.T. 206 C3 61 P1 P7 ALL SIDES I PL1 ( PL1 Fu I PL2 TRAINING A I TRAINING B 204 i 203 1 I e ON OPERABLE PARTITION PL1 PL2 TRAINING C 205 e S 8 SC1 G1 LION P7 COFFEE/COPY/FAX/PRINT sc1 245 a P 1 ALL P7 SIDES C3 B1 SC1 WD 1 LIBRARY/ CONE. 201 RECEPTION 200 .......... L OFFICE OFFICE OFFICE C1 //%�,%�i�,' 231 232 233 ENCLAVEPei '/'/'' i' '' /' ' ' '' / ' ' /'''/ /' /'''' / P6 C3 B 1 C3 Bi P 1 C3 P 1 227 /' /',',/' /' ,' / / / / / ,/' /' ,' ,/' i C2 z " /, C3 B1 ' / ' / ' / STORAGPi E C3 DEMO ',/ ,',/ �/ , ' / / ' ,' ,/ �/ ,',/ �/ SEE ENLARGED PLAN BREA 234 226 g1 /',',/ .',',/�',',/ /',',/ . o THIS SHEET FOR IT TS VCT PATTERN 244 LOS , I 245 / 1 O / , ,', ,', ,'; , ,', ,', c3 COPY 235 c2 OFFICE B1 Pi '''/' 42OW/2 C4 OFFICE 236 LIVING ROOM '; ,',',/ ,',',� ,',',/ ,',',/ ; ,',/ ,',',� , � �.F PL2 Q3 sa 225 ',';'' /',','' /' ,','' ;'' /',','' OFFICE .'; .',' , .',/ .',/ .',' .',/ ::•.�'• �• a241 Pi OFFICE ' 237 sC1 OFFICE ' 240 ::::.............................:...... .................................. ............................................. ............................. OFFICE 238 ENCLAVE , see 239 11 on a FINISH LEGEND FLOORCOVERINGS PLASTIC LAMINATE PAINT BASE CARPET - DIRECT GLUE F_P_L1__1 MANUFACTURER: NEVAMAR P1 MFG: BENJAMIN MOORE B1 VINYL BASE -2 1/2" COVE C1 MFG: ATLAS COLOR: PURE SPUN YARN -TEXTURED COLOR: MONTEREY WHITE HC -27 MANUFACTURER: JOHNSONITE CONTOUR 36 FINISH: YSN-002T FINISH: EGGSHELL COLOR: 79 BONE WHITE COLOR: CU51 AGAVE TILE BASE PLz MANUFACTURER: XXX g2 P2 MFG: BENJAMIN MOORE COLOR: PUTTY TEXTURED MFG: XXXX FINISH: S PUTTY T a OC2 CARPET - DIRECT GLUE O COLOR:MONTEREY WHITE HC -27 MFG: ATLAS FINISH: SATIN PATTERN: XXXX COLOR: XXXX PATTERN: CIRCLE BACK FINISH: XXXX COLOR: CK19 PALE IRIS PL3 MANUFACTURER: NEVAMAR P3 MFG: BENJAMIN MOOR- 63 PAINTED WOOD BASE COLOR: AMBER GREEN HAUTELINK-TEXTURED COLOR: SHADOW 2117-30 C3 CARPET - DIRECT GLUE FINISH: HLG-002T FINISH: EGGSHELL SEE DETAIL XXXX MFG: PATCRAFT WALLCOVERING 64 PATTERN: SOUND INVESTMENT i0050 MFG: BENJAMIN MOORE P 1 COLOR: 50504 MUTUAL FUNDS W 1 MFG: KNOLL TEXTILES COLOR: ROSEMARY SPRIG 2144-30 PATTERN: AVALON WC275/1 FINISH: EGGSHELL COLOR: STARDUST C4 CARPET - DIRECT GLUE CONFIRM BACKING MATERIAL WITH MFG: BENJAMIN MOORE MFG: J & J COMMERCIAL WALL PARTITION MANUFACTURER P2 PATTERN: FORM COLOR: LIGHT KHAKI 2148-40 F-1COLOR: TBD W2 MFG: KNOLL TEXTILES FINISH: EGGSHELL PATTERN: ATLANTIS WC278/8 COLOR: GRANITE MFG: BENJAMIN MOORE UPHOLSTRY C4 CARPET - DIRECT GLUE NEED ACRYLIC BACKING ON PRODUCT P3 COLOR: NUGGET AC -9 MFG: PT FINISH: EGGSHELL uP1 TYPE: ARIZONA ECK PATTERN: TBD TTBDBD O COLOR: TBD MFG: MAHARAM COLOR: NOGALES AR1040 W3 PATTERN: RAKU 397270 O CASTINGS ES COLOR: 012 RAIN P3 COLOR: CUSTOM FINISH uP2 PATTERN: STEPPINGFG: KNOLL K346 3 VCT1 VINYL COMPOSITION TILE TYPE I VINYL CONTACT: ELIZABETH GIBSON 253-3844 / MFG: ARMSTRONG COLOR: TERRA PATTERN: STONETEX EXCELON LOCATION: BOLSTER PILLOWS FOR BUILT IN DESK COLOR: 52128 DESERT DUST GLASS MFG: RUDY ART GLASS STUDIO CERAMIC WALL TILE vcT2 VINYL COMPOSITION TILE G1 717-843-3345 ❑MFG: ARMSTRONG PRODUCT #: 05169T CW MFG: XXXX PATTERN: STONETEX EXCELON LOCATION: CONF. ROOMS 203,204,205 COLOR: XXXX COLOR: 52132 DUSTY KHAKI AND ENCLAVE 227 SIZE: XXXX G2 MFG: TBD 1/4" TEMPERED ETCHED GLASS WOOD FINISH VCT3 VINYL COMPOSITION TILE BACK PAINTED TO MATCH: MFG: ARMSTRONG BENJAMIN MOORE PAINT: WOOD STAIN AND SPECIES TO MATCH ° PATTERN: STONETEX EXCELON wD1 EXISTING BUILDING STANDARD COLOR: 52150 PEAT GRAY G3 MFGn TBD SKIN SPECIES: CHERRY 3/4 TEMPERED CLEAR GLASS COLOR: NATURAL VCT4 VINYL COMPOSITION TILE LOCATION: RECEPTION DESK ®MFG: ARMSTRONG WOOD VENEER PATTERN: STONETEX EXCELON w02 FORMICA LIGNA COLOR: 52156 BAMBOO YELLOW COLOR: 4419 CARMINE SC1 SEALED CONCRETE MFG: SCOFII LD COMPANY PATTERN: CHROMIX ADMIXTURE COLOR: 0288 AUTUMN BEIGE CT1 CERAMIC TILE MFG: XXXX PATTERN: XXXX COLOR: XXXX FINISH: XXXX ENLARGED BREAK ROOM FLOOR PATTF.RN SCALE: 1/4" = 1'-0" Owner: Architecture Engineering Interiors Landscape Architecture Land Surveying rveyl 9 Corporate Office 280 East g6th Street Suite 200 Indianapolis, kWiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2002 Contractor/Consultant: Project DEBORAH WOOD & ASSOCIATE LAKESIDE CORPORATE CENTER 630 WEST CARMEL CARMEL, INDIANA 46032 Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the Wilding. the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. Drawing Title: FINISH PLAN Revisions: Issue Date Drawn By Checked By 10/30/02 SDB --- Certified By: A. e5EHt6 `t a AR 00880145 STATE OF 1 A V1 f Drawing Number. A801 Project Number. ZzzssC IW EXEC STORGE ENCLAVE EXEC. ASSISTANT 214gr OFFICE A 213 Y z 2168 216A 4'-0" 4'-0° t,=� i ®C�ONC4� 4 217 g." DIRECTOR 212 12'-515/16 L EP3 0000��� COFFEE/COPY/PRINT/FAX Ili OPEN OFFICE 249 J J__J--J--J L—_J--JI_ — -- -- -- -- -- EP3 COATS EP3 210 COFFEE/COPY/FAX/PRINT 1 EP2 6 209 ® STORAGE STORAGE ---P11 $ 207 $ ERVE 218 ENCLAVE I3 a f ri 220 '/ /,'/ ' ' / �/ // Z11 EP3 / , / / , / , /IT/-/, / LC DIRECTOR �I► Maai �Q,il �, r. i A DIRECTOR lir , FIRST FLOOR ELECTRICAL LOCATION PLAN DIRECTOR 224 OPEN OFFICE 246 I.T. 206 «t SECOND FLOOR ELECTRICAL LOCATION PLAN SCALE: 1/8" = V-0" NORTH ELECTRICAL NOTES 1. E.C. TO COORDINATE SPECIAL ELECTRICAL EQUIPMENT REQUIREMENTS OF TENANTS EQUIPMENT AS SPECIFICALLY INDICATED ON DRAWINGS VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/ OR DESIGN BUILD CONTRACTOR PRIOR TO INSTALLATION. 2. E.C. TO PROVIDE JUNCTION BOXES AT TELEPHONE AND COMPUTER LOCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE AND COMPUTER SYSTEMS (MATERIAL & LABOR) ARE PROVIDED BY TENANT UNLESS OTHERWISE INDICATED. 3. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. 4. E.C. TO COORDINATE LOCATIONS OF ALL DEDICATED OUTLETS WITH TENANT. E.C. TO INSURE DEDICATED OUTLET TYPES TO BE COMPATIBLE WITH EQUIPMENT 5. COORDINATE ELECTRICAL LOCATIONS AND CIRCUITING REQUIREMENTS WITH FURNITURE DEALERSHIP. ELECTRICAL CONTRACTOR TO HARDWIRE FURNITURE SYSTEM TO BUILDING POWER SOURCE. 6. ELECTRICAL CONTRACTOR TO COORDINATE WITH FURNITURE SUPPLIERS BASE FEED. 7. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. 8. ALL DEMOLISHED RECEPTACLES FROM EXISTING WALLS TO REAMAIN SHALL HAVE DRYWALL PATCHED AND REPAIRED PRIOR TO INSTALLATION OF WALL FINISHES. 9. WALL MOUNTED OUTLETS TO BE MOUNTED VERTICALLY 0 18' A.F.F. TO CENTER UNE OF PLATE UNLESS OTHERWISE NOTED. 10. ALL ELECTRICAL. COVER PLATES AND SWITCH PLATES TO BE COLOR IVORY 11. PROVIDE FLOOR MOUNTED POWER/COMMUNICATIONS AS TOMBSTONES OR FLUSH MOUNTED. ELECTRICAL PLAN NOTES EP1 PROVIDE POWER AND SWITCH FOR MOTORIZED RECESSED PROJECTION SCREEN. SEE ELECTRICAL DRAWINGS FOR FURTHER INFORMATION. OPROVIDE POWER FOR COPIER. E.C. TO VERIFY POWER REQUIREMENTS. PER EP2 COPIER MANUFACTURER'S SPECIFICATIONS. EP3 PROVIDE POWER FOR WORKSTATIONS FROM WALL LOCATION EP4 PROVIDE POWER FOR WORKSTATIONS FROM FLOOR CORE DRILL LOCATION EPS PROVIDE ACCESS IN BACK OF CABINET FOR ELECTRICAL AND NETWORK CONNECTION ACCESS. EP6 WALL MOUNTED 27" TV MONITOR EP7 EXISTING CYPHER LOCK --- CONTRACTOR TO GET FROM DEBORAH WOOD AND ASSOCIATES AND INSTALL EPs PROVIDE NETWORK CONNECTION EP9 PROVIDE CABLE HOOK UP FOR TELEVISION/PLASMA SCREEN M 0 TRAINING A 204� -=-A y,:..: � �4 Y 3e fie;, f i� i. �; 13 , I f�. H, i b4 ll�`NG # B 203 . .ef xa 1 cfl 1 t 'r xO �I�rwK CONNECTION , m , xo TRAINING C _ 5' x0 io DIRECTOR 202 COFFEE/COPY FAX/PRIN 245 1 56 j EP2 ' NORTH ELECTRICAL LEGEND SYMBOL DESCRIPTION Checked By NEW DUPLEX WALL OUTLET LH NEW QUADRAPLEX WALL OUTLET 6D NEW DEDICATED CIRCUIT OUTLET 6GFI NEW GROUND FAULT INTERUPT CIRCUIT OUTLET NEW IN -FLOOR DUPLEX OUTLET NEW IN -FLOOR TELEPHONE OUTLET V NETWORK CONNECTION 17 NEW VOICE/DATA WALL OUTLET (BOX AND PULL STRING) 0 NEW JUNCTION BOX +44" HEIGHT A.F.F. TO CENTER OF OUTLET MOUNTED VERTICALLY. 0 NEW POWER POLE - GC TO COORDINATE EXACT LOCATION WITH TENANT. © CABLE TV OUTLET ® BASE FEED FOR WORKSTATIONS SEE ELECTRICAL PLAN NOTES FOR WALL OR CORE DRILL LOCATION D SECURITY LOCK TO TIE IN WITH BUILDING SECURITY SYSTEM ® CYPHER LOCK X NETWORK I" i. r,u semi; I $'r55 / RECEPTION +60" 200 EP3 f OFFICE OFFICE OFFICE ' 231 232 233 ENCLAVE 227 / NETWORK CONNECTION ,' ' ,' / ' / ' ,',' / , �'h ,,• , /,' 234 DEMO " > s BREAK ROOM 8�-6" ° 24226 0� NETWORK CONNECTION / � !. 2 i / EP6 EP9 O / a COPY FAX +4 ''�''''''' ' /'''''�''''' /''+� 235 3 OFFICE / i/,'/ / / /, /. / i 242 II I II r~ ',' r /' CORKI COIF E TION` / / ' / ' / ' / ' / ' / ' / : ' i ,N I / , ' , , ' , , ' , , / , / , , n � ::�;��:'✓'• ,• OFFICE / , / , / , , , , , , , qi. ,• -.._O ' ' , / ' /' ' / �' ' , / ' ,' ' + 236 yr j„ ,/,/�/,,� ,,//,/ �; ,: •.:;i it I I� �/ -�--_—_� LI QOM ' ' S OFFICE I- i, 241 6 I I 3 / / L 1 _J / OFFICE r::: 237 / r / / , , / / , / , , / / / OFFICE ...................... ............ 240 ENCLAVE ....................... / 239 OFFICE >_ 238 *O rl go 0 EQUIPMENT LEGEND 0 COPIER -E.C. TO VERIFY EXACT ELECTRICAL AND DATA REQUIREMENTS WITH TENANT. 0 VENDING MACHINE Q REFRIGERATOR Q DISHWASHER GARGABE DISPOSAL ICEMAKER a TV Owner: Architecture Engineering Interiors Landscape Architecture Land Surveying rve� 9 Corporate Office 280 East 96th Street Suite 200 Indlanapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2002 Contractor/Consultant 11 Project DEBORAH WOOD & ASSOCIATES LAKESIDE CORPORATE CENTER 830 WEST CARMEL CARMEL, INDIANA 46032 Scope Drawings: These drawings Indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. il Drawing Title: I ELECTRICAL LOCATION PLAN Revisions: Issue Date Drawn By Checked By 10/30/02 LH LH Certified By: AR 00880145 �t ST"•TF OF Drawing Number: E201 Project Number: 22286C FIRST FLOOR PLAN L NORTH SECOND FLOOR PLAN SCALE: 1/8" = 1'-0" REFLECTED CEILING PLAN NOTES 1. REPLACE ANY DAMAGED OR MISSING TILES TO MATCH EXISTING. GENERAL_ CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND CONDITION. 2. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW 1S FOR AESTHETIC REVIEW ONLY. 3. ALL ROOM WALLS TO UNDERSIDE OF SUSPENDED CEILING, TYPICAL UNLESS OTHERWISE NOTED. SEE A200 SERIES DRAWINGS FOR FURTHER WALL TYPE INFORMATION. 4. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES, PROJECTION SCREENS OR PARTITIONS HAVE BEEN REMOVED, CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT CONDITION AS TO NOT SHOW LINE OF DEMOLITION. 5. RE -USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED FIXTURES TO BE COORDINATED WITH OWNER. ALL FIXTURES TO BE CLEANED, RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION. 6. MECHANICAL AND ELECTRICAL IS DESIGN -BUILD. DESIGN -BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN -BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. 7. RE -LAMP ALL EXISTING LIGHT FIXTURES TO MEET ENERGY SAVING REQUIREMENTS. 8. CEILING HEIGHT 1S X' -X" A.F.F. UNLESS OTHERWISE NOTED. 9. LOCATE NEW AND RELOCATED EXISTING SMOKE DETECTORS DUE TO NEW LIGHT FIXTURE LAYOUT. INFORM DESIGNER AND DESIGN BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. 10. IN LOCATIONS OF (2) TWO OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. 11. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. 12. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. 13. PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS. 14. SUPPLY/INSTALL NEW VOICE/DATA CABLE TRAY AS DIRECTED ON REFLECTED CEILING PLAN. 15. INSTALL ALL THERMOSTATES AT +72"A.F.F. TO CLEAR SYSTEMS FURNITURE PANELS. REFLECTED CEILING PLAN NOTES rPi EXISTING BULKHEAD TO REMAIN. 8 N MONITOR, MODEL, POWER, REFLECTED CEILING LEGEND NEW EMERGENCY 24 HOUR BALLAST. SPEAKER SECURITY CAMERA 1r�Er -r ESTE-..4.51.oi _5-. R12L7404-C_ N(Itt-v it2�.p — kac • 1- -%'( C.tWO o:F.;" X.1 'C t N s .F•G2 _iPtMEN� s _WW !LOW ~ C.atir�.a t.. Owner: CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 I I ®Copyright 2002 1 I Contractor/Consultant _PA? lam_. �T szt E( t�, zoo2 Project DEBORAH WOOD ASSOCIATES ADDRESS NEW 2' X 4' FLOURESCENT FIXTURE, SEE XXXXX 1 FOR SPECIFICATION. LINE NEW 2' X 2' FLOURESCENT FIXTURE, SEE XXXXX ADDRESS LIME FOR SPECIFICATION. 13: NEW DOWNLIGHT FIXTURE, SEE XXXX FOR SPECIFICATION aNEW DOWNLIGHT FIXTURE, SEE XXXX FOR SPECIFICATION LINE NEW WALL WASHER FIXTURE, SEE XXXX FOR SPECIFICATION NEW CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION DUAL -1--"1- -LITE, SEE XXXXX FOR SPECIFICATION NEW 2 X 2 LAY -IN GRID SUSPENSION SYSTEM, SEE XXXX FOR CEILING SUSPENSION SYSTEM AND CEILING TILE SPECIFICATION. NEW 2 X 4 LAY -IN GRID SUSPENSION SYSTEM, SEE XXXX FOR CEILING SUSPENSION SYSTEM AND CEILING TILE SPECIFICATION. NEW EMERGENCY 24 HOUR BALLAST. SPEAKER SECURITY CAMERA 1r�Er -r ESTE-..4.51.oi _5-. R12L7404-C_ N(Itt-v it2�.p — kac • 1- -%'( C.tWO o:F.;" X.1 'C t N s .F•G2 _iPtMEN� s _WW !LOW ~ C.atir�.a t.. Owner: CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 I I ®Copyright 2002 1 I Contractor/Consultant _PA? lam_. �T szt E( t�, zoo2 Project DEBORAH WOOD ASSOCIATES ADDRESS LINE 1 ADDRESS LINE 2 ADDRESS LIME 3 ADDRESS LINE 4 ADDRESS LINE 5 Scope Drawings: These drawings Indicate the general scope of the pro)ect in terms of architectural dtsign concept, the 6merMons of the building. the major architectural elements and the type of structural, mechanical and electrical systema. The drawings do not neceaeorily indicole or describe oli work required for full performance and completion of the requiromente of the Contract On the boeis of the general scope indicoted or deecnbed, the trade contractors sholl fumish all items roquired for the proper execution and completion of the work. Drawing Title: Revisions: Issue Date Drawn By Checked By II Certified Br. 11 0 Drawing Number: L0 Project Number: 2XXXX