Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Plans
ARCHITECT: cso 600 E. 96TH STREET, SUITE 550 INDIANAPOLIS, INDIANA 46240 (317) 848.7800 (317) 574.1869 FAX CONTRACTOR: Duke REALTY CORPORATION 600 E. 96th STREET SUITE 100 INDIANAPOLIS, IN 46240 PHONE: (317)808-6000 U*I"F DRAWINGS INDEX 0* • COVER • 1 D20 DEMOLITION PLAN • 1A201 CONSTRUCTION PIAN • 1A202 REFLECTED CEILING PAN • 1A601 ELEVATIONS &DETAILS • 1 A80 FINISH PIAN &DETAILS • 1E201 ELECTRICAL PLAN • SM -1 HVAC PLAN rl APPROVED AS SUBMITTED APPROVED AS NOTED F-1 REJECTED SIGNATURE DATE COMPANY KEYPLAN I il 'N SCALE: NTS 4 A_ C _ E�WAR�S THREE PARKWOOD SUITE 100 INDIANAPOLIS, INDIANA SPECIFICATIONS AND GENERAL NOTES 0 CONTRACT CONDITIONS 0.1 THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION, ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE RESPONSIBILMES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED AS FOLLOWS: 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE PROCEEDING WITH CONSTRUCTION. 3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND WORKMANSHIP. 10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 0.2 WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, RULES AND REGULATIONS. 0.3 ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. 0.4 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTILIZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT. 0.5 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL GOVERN THE WORK. 0.6 NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. 0.7 INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 1 GENERAL REQUIREMENTS 1.1 WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. 1.2 THE CONTRACTOR SHALL. COORDINATE AND SCHEDULE WORK BY OTHERS INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE AND "FURNISHED AND/OR INSTALLED" ITEMS. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. 1.3 CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. 1.4 SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE FOLLOWING ITEMS: .1 METAL FABRICATIONS. .2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. .3 DOORS, FRAMES AND HARDWARE. .4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6" X 6' ACOUSTICAL PANEL ). .5 VCT FLOORING AND BASE ( COLOR SAMPLES ). .6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS ). .7 PAINT ( 6" X 6" ON ACTUAL SURFACE ). .8 WALLCOVERINGS ( 9" X 9" DYE LOT CUTTING ). .9 SIGNAGE ( SAMPLE SIGN ). .10 LIGHT FIXTURES ( CATALOG CUTS ). 1.5 TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, TEMPORARY ENCLOSURES, FIRE PROTECTION, HEAT AND POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S AGENT. 1.6 THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT ADDITIONAL CHARGE TO THE PARTY AFFECTED. 1.7 THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE LENGTH OF HIS CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARMS TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. 1.8 SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBMIT THE FOLLOWING INFORMATION: .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. .2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. .3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO ACCOMMODATE THE SUBSTITUTION. .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL AFFECT THE CONTRACT SUM AND CONTRACT TIME. 1.9 STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME FOR THEIR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. 1.10 THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. 1.11 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 1.12 PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. 2 DEMOLITION 2.1 COORDINATE DEMOLITION WITH CONSTRUCTION PLANS TO DETERMINE EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW WORK. 2.2 WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. 2.3 WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL BE INCLUDED. 2.4 REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE DRAWINGS. 2.5 ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW FINISHES. 2.6 EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR NOTED TO BE REPAIRED. 2.7 SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. 2.8 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALITY OF WORK IN SCOPE OF CONTRACT. 2.9 PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. 2.10 CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTILITY SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALV OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS PLUMBING, HVAC, ELECTRICAL, AND FIRE PROTECTION SYSTEMS. CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON RECORD SEPIA TO SERVE AS PART OF THE AS -BUILT" SET. 2.11 PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT, SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. 5 METAL FABRICATIONS 5.1 PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS REQUIRED TO COMPLETE WORK. 6 WOOD AND PLASTIC 6.1 CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION GRADE" LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE CONTENT. 6.2 PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32". 6.3 FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. 6.4 FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE" AWI STANDARDS. .1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR TO FABRICATION OF MULTIPLE UNITS. 6.5 COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS). .1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL SURFACES. .2 PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE ELECTRICAL OR DATA OUTLET LOCATIONS. 6.6 CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 400B FOR PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. .1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 (0.028" NOMINAL THICKNESS); EDGES: GP -28 (0.028" NOMINAL THICKNESS). .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. .3 CABINET HARDWARE SCHEDULE: .1 HINGES: FULLY CONCEALED, SELF-CLOSING '1000 SERIES" BY GRASS OR EQUAL. .2 PULLS: WIRE PROJECTING TYPE, DRILLING 4" ON CENTER, #4483 OR EQUAL AS MANUFACTURED BY STANLEY. .3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH MINIMUM 8 LBS. PULL, # SP 45 OR SP 46 OR EQUAL AS MANUFACTURED BY STANLEY. .4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES WITH POSITIVE STOP AND LOCKOUT POSITION, WITH HEAVY-DUTY FULL EXTENSION; 11429 OR EQUAL AS MANUFACTURED BY KNAPE & VOGT. .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT OR EQUAL. 6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR 12 FURNISHINGS PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAINT IS DRY, 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, REINSTALL SUCH ITEMS. 12.1 CASEWORK: WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY i INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT .1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE OPERATING FOR TEN DAYS. SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD FOLLOWING: 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND FOR THE VARIOUS SUBSTRATES, AS INDICATED. .1 IMPERIAL CABINET CO., INC. STRAIGHT WITH NO DISTORTIONS. .2 MERILLAT INDUSTRIES, INC. 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM 1. FERROUS METAL: .3 YORKTOWNE CABINETS WIDTH NOT TO EXCEED 1/8 U.O.N. A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC 15/16 MECHANICAL AND ELECTRICAL OUTLETS. LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC 15/16.1 MECHANICAL (INCLUDING PLUMBING, FIRE PROTECTION AND HVAC) AND SEMI -GLOSS ENAMEL. ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE Ul 7 JOINT SEALERS 2. NON-FERROUS METAL: RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS 1. PRIMER: 1 COAT #41702 METALCLAD ACRYLIC CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL AND FIXTURES: LATEX PRIMER. BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, .1 "DOW CORNING 786" DOW CORNING CORP. 2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND .2 "SCS 1702 SANITARY"; GENERAL ELECTRIC CO. SEMI -GLOSS FINISH ELECTRICAL SYSTEMS. 'y .3 "863 #345 WHITE"; PECORA CORP. 3. FERROUS STRUCTURE: 15/16.2 GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF .4 "PROGLAZE WHITE"; TREMCO CORP. A. ACRYLIC DRY FOG FLAT FINISH: DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND .5 "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER PLUMBING, SIGNED AND STAMPED FOR STATE FILING PROCESS BY A REDUCIBLE ACRYLIC DRY FOG COATING CERTIFIED ENGINEER. 7.2 ACRYLIC -EMULSION SEALANT - AT INTERIOR UNLIKE ADJOINING 4. NON-FERROUS STRUCTURE: 15/16.3 IN CASE OF CONFLICT BETWEEN ARCHITECT'S AND ENGINEER'S SURFACES: A. ACRYLIC DRY FOG FLAT FINISH: DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS .1 "CHEM -CALK 600"; BOSTIK CONSTRUCTION PRODUCTS DIV. 1. FINISH: 2 COATS #57601 UNI -GRIP -WB WATER DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) .2 AC -20"; PECORA CORP. REDUCIBLE ACRYLIC DRY FOG COATING. AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL .3 "SONOLAC"; SONNEBORN BUILDING PRODUCTS 8. WOOD: DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND .4 "TREMCO ACRYLIC LATEX 834"; TREMCO, INC. A. ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. 1. PRIMER: 1 COAT #51701 WONDER -PRIME LATEX 15/16.4 SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY THE 8 DOORS AND WINDOWS PRIMER -SEALER. OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SHALL COORDINATE WITH PATTERN OF LIGHTING LAYOUT AND SHALL 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS SEMI -GLOSS ENAMEL. COORDINATE WITH OTHER CEILING COMPONENTS. ' NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. B. STAIN -VARNISH RUBBED FINISH: 15/16.5 DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED 1. FILLER: 1 COAT #4800 WONDER WOODSTAIN SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH. PASTE WOOD FILLER (OPEN GRAIN WOODS). OWNER'S AGENT. 8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH 2. STAIN: 1 COAT #96XX WONDER WOODSTAIN 15/16.6 OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED AND LOCKSETS. ALKYD STAIN. WITH THE EQUIPMENT/APPLIANCE FOR WHICH IT WAS DESIGNATED. 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 3. SEALER: 1 COAT #4900 WONDER WOODSEALER VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. QUICK DRY SEALER. EQUIPMENT. 4. FINISH: 2 COATS #4600 WONDER WOODSTAIN 15/16.7 SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE 9 FINISHES ALKYD SATIN VARNISH. GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. 10. GYPSUM WALLBOARD: 15/16.8 DATA AND COMMUNICATION CABLES ARE PROVIDED BY OTHERS AND 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. A. ACRYLIC LATEX SATIN ENAMEL FINISH: INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL ul 1. PRIMER: 1 COAT #50801 WONDER TONES LATEX COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND .1 INSTALL "ELIMINATOR" TYPE HEAD TRACK AT WALLS TERMINATING PRIMER -SEALER. TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE AT CEILING. USE PREFORMED OUTSIDE CORNERS. 2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC INSTALLATION SHALL OCCUR. -y LATEX SATIN ENAMEL. 15/16.9 DIMENSIONS, IF IDENTIFIED, ARE TO CENTERLINE OF OUTLET OR GANG OF 9.2 GYPSUM BOARD: PROVIDE 5/8" THICK REGULAR AND TYPE "X" TAPERED 13. PRECAST CONCRETE: OUTLETS, UNLESS OTHERWISE NOTED. EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND A. LATEX TEXTURE COATING -SAND FINISH (WET AREAS) 15/16.10 ALL SWITCHES AND SWITCHPLATES SHALL BE BUILDING STANDARD JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE 1. PRIMER: 1 COAT #1502 WONDER -SHIELD ACRYLIC COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. LATEX HOUSE PAINT PRIMER. IVORY. m (3 2. FINISH: 1 COAT #44101 DEV-`.'O-TEX LATEX 15/16.11 WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY .1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED TEXTURE COATING. SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILL INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH PROVIDING PROPER ACCESS TO RECEPTACLES. (♦ MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA- AND 15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND .,� 9.11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, LLE FOR SPECIFIC LOCATION. IN GYPSUM BOARD. - WITHOUT WRINKLES, GAPS OR OVERLAPS. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO 9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM.1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT OBSERVE PRIOR TO ANY COMMENCEMENT OF "ROUGH -IN" DAMAGED OR SOILED TILES. ACCEPTABLE. CONSTRUCTION. ci .2 SEAMS MUST BE AT LEAST 2" FROM INSIDE CORNERS AND 6" FROM .1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS OUTSIDE CORNERS. IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL GN GENERAL NOTES REFLECTED CEILING PLAN SHALL GOVERN. 10 SPECIALTIES .2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS 10.1 ARE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO 0 own UNLESS NOTED OTHERWISE. BUILDING STANDARD, PROVIDE JL INDUSTRIES AMBASSADOR' SERIES, PROCEEDING WITH CONSTRUCTION. SEMI RECESSED, DUO -PANEL, FIELD PAINTED. GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR - CASED OPENING UNLESS NOTED OTHERWISE. A TO FINISHED FACE OF GYPSUM BOARD. B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS. .1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET C. TO TOP OF FINISHED FLOORS. MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH D. TO BOTTOM OF FINISHED CEILINGS. CARPET. GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, G �` 9.6 RESILIENT FLOORING: EXISTING CONSTRUCTION AND WALL TYPES. GNA TERMINATE WALLS AT UNDERSIDE OF CEILING UNLESS INDICATED Q .1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS OTHERWISE. ESTABLISHED WITH PRINCIPAL WALLS, SO THAT TILE AT GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITI N�C60 OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIO AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER. SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF1� .2 BASE: FIT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCE ��� V� BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING WITH CONSTRUCTION. (j ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT ri FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. 9.7 USE AN APPROVED CEMENTITIOUS FILLER TO PATCH CRACKS, SMALL DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM OBSERVATION. SURFACE VARIATION OF '%" IN 10 FEET, NON -CUMULATIVE. GN.7 FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4" IN 20'-0" NON- CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING STANDARDS: GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO CLOSE -IN OF WALLS. FLAMMABILITY: ASTM 2859 GN.9 SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT _ PERIMETER WITH ACOUSTICAL OR FIRE RATED SEALANT AS APPLICABLE. SMOKE DENSITY: ASTM SURFACE BURNING: ASTM E66 PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. 0 1423 PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED 6E FADE RESISTANCE: AATCC i 6E SOUND ABSORPTION: ASTM TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL STATIC RESISTANCE: AATCC 134 JUNCTION BOXES ARE NOT PERMITTED. WARRANTY: 10 YEARS GNAO ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY , CONTRACTOR. .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. 3-28-02 CSO #22124 F_ 17 M 01 L= 44 +44 I I b b a b� +44" +4D� G DP 1 +4i +4< D +44 DEMOLITION PLAN SCALE: 1/8" = V-0" FR (L1 D �I q AV �� tI� ®® AL1` ISD_ �1 LP o FH1 _ D f (L1 77— 77 F��, ° )1A �� xx < 220V '4 \ 10V 110v1 1ov 110V (LP DEMOLITION NOTES 1. DEMOLISH DENOTED EXISTING CEILING SYSTEM, CLEARLY AND CLEANLY BACK TO A POINT WHEREAS INSTALLATION OF NEW CEILING SYSTEM IS POSSIBLE. 2. DEMOLISH EXISTING TO BE REMOVED WALL SURFACES BACK TO A POINT WHEREAS INSTALLATION OF NEW FLOORING FINISHES IS POSSIBLE. 3. REMOVE ELECTRICAL AND DEVICE LINES IN WALLS THAT ARE SHOWN INCLUDING ALL ATTACHED WIRING. DEMOLISH ELECTRICAL DEVICES AND WIRING BACK TO A POINT WHEREAS PROPER PREPARATION FOR NEW FINISHES IS POSSIBLE. SEE ELECTRICAL AND FINISH PLANS FOR FURTHER INFORMATION. 4. REMOVE ALL WALLS, MILLWORK, DOORS, SIDELITE, AND DOOR FRAMES AS SHOWN DASHED. RESERVE DOORS AND DOOR FRAMES FOR RE -USE IN THE NEW PROJECT SCOPE. 5. REMOVE ALL EXISTING FINISHES WHERE NEW FINISHES ARE TO BE INSTALLED. REFERENCE FINISH SHEET, A801, TO COORDINATE LOCATIONS OF NEW FINISHES 6. REMOVE ALL EXISTING FLOOR OUTLETS, POWERPOLES AND JUNCTION BOXES SHOWN. PROVIDE AN EVEN FLOOR OR WALL SURFACE IN PREPARATION FOR NEW FLOOR FINISH. DEMOLITION PLAN NOTES DP) REMOVE EXISTING CASEWORK AND SAVE CABINETRY FOR REUSE. REMOVE EXISTING SURFACE MOUNTED FIRE EXTINGUISHER AND SAVE FOR RE -USE. VERIFY EXISTING DRAIN WITH PROPERTY MANAGMENT, SYSTEM WILL NEED TO BE FLUSHED AND PLUMBING CAPPED OFF. DEMO. ELECTRICAL OUTLET LEGEND ==== EXISTING CONSTRUCTION TO BE REMOVED EXISTING PARTITION TO REMAIN DENOTES AREA NOT IN CONTRACT 6 ` uAke REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone:(317) 808-6000 Fax: (317) 808-6797 N71 EXISTING DUPLEX WALL OUTLET TO BE DEMOLISHED Engineering EXISTING QUADRAPLEX WALL OUTLET TO BE DEMOLISHED ,,D EXISTING DEDICATED CIRCUIT OUTLET TO BE DEMOLISHED ® EXISTING POWER POLE OUTLET TO BE DEMOLISHED 0 EXISTING POWER POLE OUTLET TO BE DEMOLISHED V EXISTING PHONE WALL OUTLET TO BE DEMOLISHED �� EXISTING JUNCTION BOX TO BE DEMOLISHED WALL LEGEND - ==== EXISTING CONSTRUCTION TO BE REMOVED EXISTING PARTITION TO REMAIN DENOTES AREA NOT IN CONTRACT 6 ` uAke REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone:(317) 808-6000 Fax: (317) 808-6797 N71 M cso ArcW* tre Engineering Interiors l.snd®cape Archkwwre Lud Suing Six Parkwood Office 600 East 96th Street, Suite 550 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 @Copyright 2001 (N 0 I Ib CV I r� z 0 0 st O O mp mV co _� CV U ar op o t!) Q z � Z oQ Q Ix Q o 0 J 0. Q QY- Z 0 LU Q �0 a H H W �W12 _ J ® coza Q ~0 W Q z 0 Certified By: Drawing Number: 1D201 Of Sheets Duke Job Number: A/E Job Number: 22124 M CONSTRUCTION PLAN oa01r-El SCALE: 1/4" = 1'-0" 1/8" = 1'-0" J—V J—V w Q Z C) DOOR FRAME HARDWARL REMARKS SIZE J � Q O _1 lLl Q Q O J W L J w U� ck: VOnOQOf O () < UD N V) _j mck� N CL U o cf> I— 'S C.� W = U H 100 RECEPTION E X I S T I N G L,S,DB L � <o 3'-0" 8'-0" 1 3/4" WOOD D3 HM D3 PS,S CO) 102 CLOSET H Q 3'-0" 8'-0" 1 3/4" WOOD W HM D3 L,S 103 CAGE 8'-0" 1 3/4" WOOD D3 HM D3 SRL,S 104 PHONE SERVER 3'-0" 106 CONFERENCE 203'-0 8'-0" 1 3/4" WD/GL 0 HM D2 PS,S 8'-0" 1 3/4" j U D4 HM D4 PS,S /i 108A C/F STORAGE 3'-0" 108B C/F STORAGE 3'-0" 8'-0" 1 3/4" WOOD D4 o� D4 S,PS 109 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 S,PS 110 CORRIDOR E X I S T I N G L,S,DB �z 111 OFFICE 3'-0" 8'-0" 0 WOOD D1 HM D1 PS,S 112 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 �LAJ 114 OFFICE 3'-0" r 1 3/4" WOOD 0 HM D1 PS,S 115 O w 3'-0" 8'-0" 1 3/4" WOOD D1 U D] D1 PS,S 116 OFFICE HARDWARE TIMELY FRAME 1/4" TEMPEREE GLASS INSET - LEVER HARDWARE CONSTRUCTION PIAN NOTES FP1 ALIGN FINISHED FACES. FP2 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 13/1A601. FP3 NEW OR RELOCATED WALL MOUNTED FIRE EXTINGUISHER TO BE INSTALLED ON WALL AT THIS LOCATION. FP4 PROVIDE 1/4- COLD COPPER LINES WITH VALVE FOR TENANT SUPPLIED ICE MAKER/REFRIGERATOR AND COFFEEMAKER. VERIFY EXACT LOCATION OF ALL APPLIANCES, REQUIRING A WATER SOURCE. SEE DETAIL 12/1A601. FP5 PROVIDE STANIDARD HEIGHT CDATAIRLOD AND SHELF WITH 1/3 AT ADA ACCESSIFP6 COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. VERIFY ELECTRICAL REQ. WITH MANUF. MANUAL. (5) 12"dp. 3/4" WHITE MELAMINE SHELVES ON HEAVY DUTY KV 187-72" FP7 STANDARDS & KV 87-12" BRACKETS. PROVIDE ADDITIONAL BLOCKING AS REQ'D PROVIDE ADDITIONAL BLOCKING AS REQUIRED. SEE DETAIL 10/1A601. FPa REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. PROVIDE 3/4" x 4' x 8' FIRE RETARDANT PLYWOOD PHONE BOARD. PHONE BD. FP9 PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH. EXACT LOCATION OF PHONE BD TO BE DETERMINED BY TENANT. Pio RELOCATE EXISTING CABINETRY TO THIS LOCATION. RETROFIT TO NEW SPACE, INSTALL NEW LAMINATE TOP. OFP>> MILLWORKER TO VERIFY EXISTING COUNTERTOPS OVER FILING AT CURRENT TENANT LOCATION. LENGTH TO BE CUT ACCORDING TO NEW FILING SPACES. MILLWORKER TO BUILD NEW PLASTIC LAMINATE (PL2) FILE COUNTERTOP TO P12 MATCH SIZE OF EXISTING FILE COUNTERS AT EXISTING TENANT LOCATION. COUNTERTOP TO REST ON TOP OF FILE CABINETS. P13 LOW WALL TO RECIEVE PLASTIC LAMINATE CAP, REFER TO 15/1A601 FOR DETAIL CHEDULE NOTES 1. HLL LA101 nvV vvvnJ - - - - - TO MATCH TENANT FURNITURE, CHERRY STAIN. SAMPLE TO BE PROVIDED BY PROJECT DESIGNER. OFFICE DOORS TO BE CUT FOR GLASS INSET. REFER TO DOOR ELEVATIONS. 2. PROVIDE NEW MEDIUM E LEVER HARDWARE TO MATCH BUILDING DARD WHERE NEEDED. 3. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 4. COORDINATE KEYING LOCKSETS WITH TENANT. 5. ALL RELOCATED DOOR FRAMES ARE TO BE PREFINISHED TO MATCH BLDG STANDARD. 6. ALL WOOD DOOR FRAMES ARE TO BE STAINED TO MATCH REFINISHED DOORS. F;D 0 0 R S C H E D U L E Z W �M O Z w Q Z C) DOOR FRAME HARDWARL REMARKS SIZE J � Q O _1 lLl Q Q O J W L J w U� ck: VOnOQOf O () < UD N V) _j mck� N CL U o cf> I— 'S C.� W = U H 100 RECEPTION E X I S T I N G L,S,DB L � <o 3'-0" 8'-0" 1 3/4" WOOD D3 HM D3 PS,S CO) 102 CLOSET H Q 3'-0" 8'-0" 1 3/4" WOOD D3 HM D3 L,S 103 CAGE 8'-0" 1 3/4" WOOD D3 HM D3 SRL,S 104 PHONE SERVER 3'-0" 106 CONFERENCE 203'-0 8'-0" 1 3/4" WD/GL D2 HM D2 PS,S 8'-0" 1 3/4" WOOD D4 HM D4 PS,S 108A C/F STORAGE 3'-0" 108B C/F STORAGE 3'-0" 8'-0" 1 3/4" WOOD D4 HM D4 S,PS 109 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 S,PS 110 CORRIDOR E X I S T I N G L,S,DB 111 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 112 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 114 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 115 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 116 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 117 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 118 CORRIDOR 3'-0" 8'-0" 1 3/4" WOOD D3 HM D3 L,S,CL RELOCATED, KEYPAD 119 BREAK ROOM 3'-0" 8'-0" 1 3/4" WOOD D4 HM D4 PS,S 120 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 121 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 123 OPEN OFFICE 3'-0" 8'-0" 1 3/4" WOOD D3 HM D3 L,S,CL RELOCATED, KEYPAD 124 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 125 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 126 MAN. OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 L,S 127 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 128 OFFICE OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 129 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 130 OFFICE OFFICE 3'-0" 8'-0" 1 3/4" WOOD -WOOD D1 HM D1 PS,S 132 3'-0" 8'-0" _13/4" D1 HM D1 PS,S 133 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 134 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 135 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 136 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 137 OFFICE 3'-0" 8'-0" WOOD D1 HM D1 PS,S 138 OFFICE 3'-O" 8'-0" r13/4"l /4" WOOD D1 HM D1 PS,S 139 OFFICE 3'-0" 8'-0" /4" WOOD D1 HM D1 PS,S 140 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S 141 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 PS,S CONSTRUCTION NOTES 1. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. 2. SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES. 3. SAVE ALL REMOVED ITEMS FOR OWNER, PER OWNER'S DIRECTION, UNLESS OTHERWISE SPECIFIED 4. REUSE DOORS, FRAMES, AND PARTITIONS SYSTEMS AS MUCH AS FEASIBLE. VERIFY WITH ARCHITECT AND OWNER ANY ITEMS WHICH ARE QUESTIONABLE FOR REUSE. 5. ALL NEW DOORS TO BE HINGED 6" AWAY FROM WALL. 6. PROVIDE CONCEALED WALL BLOCKING AS REQUIRED WHERE NEW SHELVING, PLUMBING AND CASEWORK ARE NOTED. 7. ALL WALLS SHALL BE CHAULKED OFF FOR DESIGNER'S REVIEW TO NEW WALL CONSTRUCTION 8. ALL NEW DOORS SHALL ALLOW 12" CLEAR ON PUSH SIDE AND 18" CLEAR ON PULL SIDE OF DOOR UNLESS NOTED OTHERWISE TO MEET ADA CODE REGULATIONS. 9. ALL NEW WORKSURFACES TO RECIVE 2-1/2" GROMMETS. NEW GROMMET LOCATIONS TO BE VERIFIED WITH TENANT IN FIELD AND WITH RESPECT TO NEW ELECTRICAL LAYOUT 10. ALL WALLS SCHEDULED TO REMAIN (I.E. COORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. 11. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. 12. ALL NEW TRACK AND TRIM AT WALL/CEILING CONDITIONS SHALL MATCH EXISTING COLOR AND MATERIAL TO PROVIDE CONTINUOUS/CONSISTENT APPEARANCE THROUGHOUT CEILING, 13. BUILDING OWNER AND/OR G.C. TO PROVIDE MINISBLINDS AT ALL PERIMETER WINDOWS. EXISTING MINIBLINDS TO BE RELOCATED ARE TO BE STORED DURING CONSTRUCTION PHASE, THEN CLEANED AND REINSTALL UPON COMPLETION OF CONSTRUCTION. 14. ALL NEW AND EXISTING WALL MOUNTED FIRE EXTINGUISHERS TO BE RELOCATED WHERE NOTED. LIFSAFETY CONTRACTOR TO VERIFY NEED FOR ANY ADDITIONAL FIRE EXTINGUISHER CABINET LOCATIONS. IF ADDITIONAL FIRE EXTINGUISHER CABINETS ARE REQUIRED, LOCATIONS OF MUST BE SUBMITTED TO CSO INTERIORS FOR LOCATION REVIEW FOR AESTHETICS PURPOSES ONLY. 15. EXISTING DOORS AND DOOR FRAMES TO BE REMOVED DURING CONSTRUCTION PHASE, CLEANED AND REINSTALLED UPON COMPLETION OF CONSTRUCTION. DOORS THAT ARE QUESTIONABLE FOR REUSE, PLEASE CALL FOR DESIGNERS REVIEW AND APPROVAL OF REUSE BEFORE INSTALLATION. WALL LEGEND- NOTE: ALL WALLS TO BE W1 UNLESS OTHERWISE NOTED EXISTING PARTITION TO REMAIN W1= NEW WALL CONSTRUCTION TO BE: 2-1/2" METAL STUDS @ 24" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING LINE. W2= NEW LOW WALL CONSTRUCTION TO BE 42" A.F.F.: 2 1/2" METAL STUDS @ 24" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. PROVIDE STAINED WOOD CAP TO MATCH DOORS. W3= NEW WALL CONSTRUCTION TO MATCH ADJACENT CORRIDOR WALL CONSTRUCTION. DENOTES AREA NOT IN CONTRACT DENOTES NEW MILLWORK NEW DOOR AND FRAME. SEE DOOR SCHEDULE. 1/2" QUARTER ROUND EDDGE AROUND FRAME \ APPLIED 1 " WOOD MULLIONS WITH 1/4' STEP L9qWq arr�lw � SCALE: 1 "=1'-0" Duke REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 cso ArchkeCttlre Engineering InWor8 Uindec" AnIliibedure Lend Surveying Six Parkwood Office 600 East 96th Street, Suite 550 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 Wopyright 2001 N 0 I ao N I r7 z 0 V) 0 st C4 O O _ m 0 m 0 /U� CD i U �/ N/ Q) CO o� 60 0 o o W U Certified By: Drawing Number: 1A201 Of Sheets Duke Job Number: A/E Job Number: 22124 ,j :y 1 J Q J ® 0 z Q a 000 o- Z L � <o (j) W ,j a- • R CO) � z Q H Q z Z W U Certified By: Drawing Number: 1A201 Of Sheets Duke Job Number: A/E Job Number: 22124 ,j :y 1 J REFLECTED CEILING PLAN SCALE: 1/8" = V-0" i REFLECTED CEILING PLAN NOTES 1. REPLACE ANY DAMAGED OR MISSING TILES TO MATCH EXISTING. GENERAL CONTRACTOR TO VERIFY EXISTING GRID LAYOUT AND CONDITION. 2. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN/BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO CSO INTERIORS FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. CSO INTERIORS REVIEW IS FOR ASTHETIC REVIEW ONLY. 3. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED. CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT CONDITION AS TO NOT SHOW LINE OF DEMOLITION. 4. RE—USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED FIXTURES TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED, RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION. 5. MECHANICAL AND ELECTRICAL IS DESIGN -BUILD. DESIGN -BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS AND THERMOSTATS. DESIGN -BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. 6. CEILING HEIGHT IS 8'-6" A.F.F. UNLESS OTHERWISE NOTED. 7. IN LOCATIONS OF (2) TWO OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLODATED TO A GANG PLATE CONDITION. 8, CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DESCREPANCIES TO ARCHITECT AND/OR DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. 9. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. 10. VERIFY THAT EXISTING CEILING GRID IN THE EXISTING TWO SUITES ARE COMPATABLE IN BUILDING STANDARD CEILING GRID AND TILES AND ALIGN WITH ONE ANOTHER. REELECTED CEILING PLAN NOTES CPi NEW CEILING GRID TO ALIGN WITH EXISTING. 8NEW THREE—WAY SWITCHING FOR CORRIDOR TO BE SWITCHED FROM THIS LOCATION REFLECTED CEILING LEGEND EXISTING 2 X 4 FLOURESCENT LIGHT TO REMAIN NEW OR RELOCATED 2' X 4' FLOURESCENT FIXTURE, BUILDING STANDARD SPECIFICATION. EXISTING 2 X 4 FLOURESCENT FIXTURE TO BE REMOVED D _ NEW OR RELOCATED 2' X 2' FLOURESCENT FIXTURE, BUILDING STANDARD SPECIFICATION. D EXISTING 2 X 2 FLOURESCENT FIXTURE TO BE REMOVED X -i EXISTING DOWNLIGHT TO BE REMOVED XRELOCATED DOWNLIGHT FIXTURE N: NEW DOWNLIGHT FIXTURE, NEW WALL WASHER FIXTURE, SEE XXXX FOR SPECIFICATION t EXISTING CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION DUAL—LITE t; RELOCATED CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION DUAL—LITE t; NEW CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION DUAL—LITE, SEE XXXXX FOR SPECIFICATION EXISTING CEILING MTD. EXIT LIGHT W/ DIRECTION INDICATION DUAL—LITE TO BE DEMOLISHED EXISTING 2 X 2 LAY—IN GRID SUSPENSION SYSTEM TWO WAY SWITCH TD NEW DIMMER SWITCH T3 THREE—WAY SWITCH NL NIGHTLIGHT LOCATION 6 `� Ue REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: (317) 808-6000 Fax: (317) 808-6797 .y 4 I d 1 so AArchkecture Engineering Interiors Umdecape Architecture L and Surveying Six Parkwood Office 600 East 96th Street, Suite 550 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 N O I a� N I z 0 Vn n w 0 N a� C4 t m0 �V �CO R: Q)V goo n a O o U Z Q J CA Q a d oa 000 Z Q Y z .J c� W �°0 W = W Q 0 tr z W Q U ® F-0 z W J LL W Certified By: Drawing Number: 1A202 Of Sheets Duke Job Number: A/E Job Number: 22124 .y 4 I d 1 I 'y ue REALTY CORPORATION 12" 600 East 96th Street Suite 100 1/2"HW, UPPER CABINETS TO BE 12" Indianapolis, IN 46240 1/2 -CW, TIMBERLAKE WHITE WITH Phone: (317) 808-6000 PREFINISHED ALUMINUM 4" CHROME WIRE PULLS AND UPPER CABINETS TO BE Fax: (317) 808-6797 UPPER CABINETS TO BE TIM ERLAKE WHITE WITH RECIEVER TRIM "G8350"— �� i „ & 1-1/4"V FASTEN AT WINDOW SILL (2) ADJUSTABLE SHELVES TIMBERLAKE BAINBRIDGE WITH 4 CHROME WIRE PULLS & & SET IN A CONTINUOUS I 4" CHROME WIRE PULLS AND TYPICAL WALL TYPE BEAD OF ACCO CONTINUOUS SEALANT `� F� ZO" dX1-1/2" PLASTIC LAMINATE (PL2) TRIM COLOR TO MATCH (2) ADJUSTABLE SHELVES COUNTER WITH 4" BACKSPLASH. �' (2) ADJUSTABLE SHELVES BLDG. WINDOW MULLIONS. ® N N I TYPICAL AT ALL EXTERIOR WALLS— 5(8" TYPE X G.W.B. LINE OF EXISTING WINDOW FINISH BELOW EXISTING SILL COVER BELOW WINDOW SILL COVER 25" dX1-1/2" PLASTIC I CONNECT TO LAMINATE (PL1) COUNTER 25"D X1-1/2" PLASTIC / 25' dX 1 1 2 PLASTIC BUILDING MAINS ICN 2'-1" WITH 4 BACKSPLASH ( ) LAMINATE PL2 COUNTER LAMINATE (PL1) COUNTER WI H 4" BACKSPLASH II & ENDSPLASH AS REQ. & ENDSPLASH AS REQ. I N 2'- WITH 4" BACKSPLASH I N------------Ir------------==-Ir LOWER CABINETS TO BE 11 1111 _ SINK X4"VINYL4'-0" ERLAKE - BAINBRIDGE = cso STAINLESS STEEL DOUBLE i c 1 i c i i' 1 1 II I ' LONER CABINETS TO BE 4" WIRE PULLS AND BOWL SINK WITH PADDLE I 1, I1 11 I TI BERLAKE - BAINBRIDGE I _______ J L--------------JII�--------------J W p��� ��O O���y — — ADJUSTABLE SHELF I ----- i i -------------- 1 ii °�� ��� �\�� » ONEHANDLE HARDWARE i i -- i i illi i l \`\ ������� ��� WI H 4 WIRE PULLS AND deCture .� METAL STUD o i c c II `� ''I I\'`, 0 E ADJUSTABLE SHELF Engineering I1 c== 111 I —= I I Q ��\QUO ` 0 CONTINUOUS BEAD OF - — 3/4" PLAS. LAM. (PL2) I i ` \ OHO O� fe ACOUSTICAL SEALANT '`� I i W OHO O �`� ���m� • ,�` I I IIII I J � ������ � � �������� �' / / / \ \ � �. i.w"a�wwMv NL�IteMr 1� 11 I1 I I 11 Q J� ���0 REMOVABLE PANEL III' ----- 1 1 ---- , I l r-------------- , U �, �., y �= , __J 2'W - Ir-------------- II Ir---------- II O O� �y L�g714 Surveying OCKING IN `�' N 7 r—_------- II �\� : ` r �" 1 Q I IIII " ` ` \ �� LL AS REQ D w = ; 1 ' u' ; I ;. ;.;;;�"�:,�,�� b N J =— — I U „ 11 IIII \��`����`� $�0 PBfkWOOd CB VINYL BASE I I 1 _ Soo East sstn street, suite 550 jl IL _ JII�--- 1-� J� L� ---__ ___=__� 1--------------- =— �__—____________ ___ �� Indianapolis, Indiana 46240 317.848.7800 TO BUILDING BASE (B1) 12'-9" 6'-$y^ FAX 317.574.0957 ®copyl9nt zoos DRAIN CASEWORK CASEWORK 00 00 MULLION CASEWORK PLUMBING SECTION 8 COUNTERTOP ELEVATION 1 ELEVATION SECTION 6 _ 13 DETAIL _ � _ _ _ � (�l2 SOMETRIC 1 A601 SCALE: 1/2" 1'-0 SCALE: NTS " 1 A601 SCALE: 1/2" = 1'-0" 1 A601 SCALE: 1 /2" - 1' 0" 1 A601 SCALE: 1 /2" 1'-0" '4 1 A601 SCALE: NTS 1 A601 Z 0 > Li o 10 431-40" 8 rz 7 1A601-0" 1 ' 0C4,_04 -04_0_r;;; '-6 _ UPPER CABINETS TO BE %%; fi C) m V :y HR UPPER CABINETS TO BE TIMBERLAKE WHITE WITHCID ` TIMBERLAKE WHITE WITH U „ _ 1,-6„ -------- -- \-- ;\\ --- =- /--- -- — - -- -- -- ---\ - -- -- =---- ----= -- 2 CADJLL OUSTABLEME ESHELVESPULLS AND 4" CHROME WIRE PULLS AND \ r o p o 1 /4 PLEXI GLASS () (2) ADJUSTABLE SHELVES ,;,;,% DIVIDERS THAT SLIDE INTO 1/2"D WOOD NOTCH 1'-0 „ IN 1 THK W � --- --- -----------�--- PAINTED TO MATCH(WC1) 3/4 WHITE MELAMINE �� ---- -�--- -�-- �----- �--- � ---- \ SHELVING �`,I I, ,I I,�'', .I i,',I I,'� TRANSACTION TOP „ 25" dX 1-1 /2" PLASTIC 25" dX 1-1 /2 PLASTIC 3/4 WHITE MELAMINE LAMINATE 1 /2" COUNTER LAMINATE (PL2) COUNTER WITH 4" BACKSPLASH o WITH 4" BACKSPLASH & ENDSPLASH AS REQ. I & ENDSPLASH AS REQ. 3/4"D HARDWOOD END N SUPPORTS (TYP. EACH END. 1-1/4" dia. CHROME ROD LOWER CABINETS TO BE — — LOWER CABINETS TO BE — _ — — — — — — TIMBERLAKE - BAINBRIDGE TIMBERLAKE - BAINBRIDGE o � WITH 4" WIRE PULLS AND WITH 4 WIRE PULLS AND - I I ONE ADJUSTABLE SHELF ONE ADJUSTABLE SHELF o Ire NOTE: WHERE SPAN EXCEEDS '------------------- 4'-0" A CENTER SUPPORT r BRACKET IS TO BE USED 4,-0„ 4,-0„ 4,_0„ 4'- 8'-6 2-1 cn Q Q 4,-0„ WORK SURFACE ® 0 z 16'-0" � o o W Q�z MAILBOX COAT ROD 2 CASEWORK ELEVATION w IL(`q�DETAIL 5 CASEWORK ELEVATION SCALE: 1/2" = 1-0 ~0 Z 14 DETA1A601 W W 12 601 SCALE: 1 " = 1'-0" 1 A601 SCALE: 1/2- = 1'-0" 1 A601 SCALE: 1 /2" = 1 -0 co�z — Q H �o Q z > W J 8 W 3'-0» 3,-0" 1A601 3,-0» 3'-0" 15"dX1-1/2" PLASTIC LAMINATE UPPER CABINETS (PL1) TRANSACTION TOP RELO "ATED FROM 2" PLASTIC LAMINATE (PL1 EXIST NG SPACE SWINGING DOOR WITH LEVER HARDWARE 1-1/2 11 PLASTIC LAMINATE (PL2) --- ---���� COU N3TSR WITH 4" BACKSPLASH. AND GROMMETS WITH IVORY COVERS 3" GROMMET WITH COVER ---- ---% - MAILBOX SLOTS BUILT INTO WALL "— 1 2" 14"dX1-1/2" PLASTIC LAMINATE `,I �,��' REFER TO DETAIL 14/A601 W X '� 6 / TRANSACTION TOP K & V SHELF STANDARDS THK PLASTIC/(PL1)#87-78" (VARIES) J 3" GROMMET WITH COVER BUILT-OUT MAILBOXES, REFER NEW 25"D PLASTIC LAMINATE(PL1 TO 14/A60 LAMI ATE (PL1) TOP LOW WALL CAP 1-1/2" PLASTIC LAM (PL2) COUNTER WITH 1' O" GROMMETSBACKSPWITH IVORY COVERS K & V SHELF BRACKETS _ — (� _�� 18" DEPTH L� Certified By: 6„ LOW CABINETS o RELO ATED FROM C° � ' EXIST NG SPACE ------ ------ --- - 3" GROMMET AND CUT-OUT 00 PEN 4" KICK IN SUPPORT BRACKET '' ' - 1 "thk. PLASTIC LAMINATE 3/4" WHITE MELAMINE 4'-Q" 3'-6" 2'-7" 6" 3'-0» �» 4'-0 N (_PL2) SUPPORT BRACKETS SHELVING W 3 -0„ ITH END PANELS 3'-0" 3'-0" 3'-0» ' 18'-4" 12'-0" o Drawing Number: 1Af01 \\—BLOCKING AS REQUIRED Of Of Duke Job Number: CASEWORK SHELVING�3CASEWORK ELEVATION 4 CASEWORK ELEVATION ,_.DETAIL 11 SECTION 10 SECTION" 1A601 SCALE: 1/2" = 1 0 A/E Job Number: 1 A601 SCALE: 1 /2 = 1 -0' L' A601 SCALE: 1/2" = 1'-0" 1 A601 SCALE: 1/2' = 1'-0° 1 A601 SCALE: 1/2" = 1'-0" 22124 , FINISH PLAN SCALE: 1/8" = V-0" X// FINISH GENERAL NOTES 1, ALL DOORS TO BE FINISHED TO MATCH BUILDING STANDARD. 2. ALL DOOR FRAMES TO BE FINISHED TO MATCH BUILDING STANDARD. 3. ALL WOOD TRIM TO BE FINISHED TO MATCH BUILDING STANDARD. 4. G.C. TO PROVIDE VINYL REDUCER STRIP TO MATCH VINYL BASE WHERE CARPET AND VINYL TILE TRANSITIONS TAKE PLACE. 5. PAINT PLYWOOD PHONE BOARD/S WITH FIRE RETARDANT PAINT, COLOR TO MATCH ADJACENT WALL FINISH. 6. PAINT EXISTING FIRE EXTINGUISHER CANINETS TO MATCH ADJACENT WALL FINISH. 7. CARPET TO CARPET AND/OR CARPET TO HARDSURFACE FLOORING TRANSITIONS TO BE FEATHERED AS REQUIRED TO PROVIDE A SMOOTH TRANSITION FROM FINISH TO FINISH 8. G.C. TO SUBMIT STAINED AND/OR PAINTED SAMPLE OF MILLWORK, TO ARCHITECT AND/OR DESIGNER FOR REVIEW AND APPROVAL, BEFORE FINISHES BEFORE PROCEEDING WITH MILLWORK FINISHING PROCESS. 9. PROVIDE MINIBLINDS TO MATCH BUILDING STANDARD MINIBLINDS , AT ALL PERIMETER AND INTERIOR WINDOWS. FINISH PLAN NOTES 9 PROVIDE 4" PLASTIC LAMINATE (PL1) CAP ON ALL LOW WALLS. FINISH LEGEND FLOORCOVERINGS C 1 CARPET - DIRECT GLUE MFG: SHAW PATTERN: INTERACTIVE BL 60277 COLOR: BORDEAUX 77830 LOCATION: THROUGHOUT vCT1 VINYL COMPOSITION TILE MFG: MANNINGTON PATTERN: ESSENTIALS COLOR: 137 SANDRIFT PATTERN: RANDOM (60%) vCT2 VINYL COMPOSITION TILE MFG: MANNINGTON PATTERN: ESSENTIALS COLOR: 255 FROSTED JADE PATTERN: RANDOM (20%) VCT3 VINYL COMPOSITION TILE MFG: MANNINGTON PATTERN: ESSENTIALS COLOR: 239 BROWN EARTH PATTERN: RANDOM (20%) ST1 STONE MFG: STONE DESIGN STYLE: SLOPE BASE 0B, VINYL BASE -4" COVE BASE MANUFACTURER: VPI COLOR: 29 MOON ROCK WOOD FINISH OWOOD STAIN TO MATCH ws1 EXISTING DOORS WALLCOVERING W1 MFG: DL COUCH PATTERN: AGATE COLOR: BEV -9558-54 DESC: TYPE 1 W2 MFG: MDC, LEN-TEX PATTERN: CATALAN COLOR: MARSH 1515 -CT DESC: TYPE 1 VU3 MFG: DL COUCH/VERSA PATTERN: MORENO COLOR: A49-875 MONTEREY DESC: TYPE 1 W4 MFG: DL COUCH/SYMPHONY PATTERN: SELECT PROGRAM COLOR: SSP36 DESC: TYPE II PAINT P 1 MFG: BENJAMIN MOORE COLOR: HC -105 FINISH: EGGSHELL P2 MFG: BENJAMIN MOORE COLOR: HC -113 FINISH: EGGSHELL PLASTIC LAMINATE PL1 MANUFACTURER: WILSONART COLOR: 4813-60 NICKEL EV FINISH: TEXTURED Flt MANUFACTURER: NEVAMAR COLOR: ES -7 -IT WHITE ESSENCE FINISH: TEXTURED Duke `• REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: 317 808-6000 Fax: 317 808-6797 ;y I i cso Arch�Cture Er4lneering Interiors Undecape Architecture Land Sur ying Six Parkwood Office 600 East 96th Street, Suite 550 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 @Copyright 2001 N O I 00 N I z O V) U) �C 0 a� o' O cy O eco �V a0 J cn Q Q � Z oQ �— 000 W � Qom -0a p Uja_o z W = Lj a- . co a � Q �o = a zcr) E W Certified By: Drawing Number: 1A801 Of Sheets Duke Job Number: A/E Job Number: 22124 ;y I i ELECTRICAL PLAIN SCALE: 1/8" = 1'-0" ELECTRICAL NOTES 1 . E.C. TO COORDINATE ELECTRICAL REQUIREMENTS FOR SPECIAL EQUIPMENT WITH TENANT. 2. E.C. TO PROVIDE JUNCTION BOXES AT TELEPHONE AND COMPUTER LOCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE AND COMPUTER SYSTEMS (MATERIAL & LABOR) ARE PROVIDED BY TENANT UNLESS OTHERWISE INDICATED, 3. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. 4. E.C. TO INSURE DEDICATED OUTLET TYPES TO BE COMPATIBLE WITH EQUIPMENT 5. FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. COORDINATE ELECTRICAL LOCATIONS AND CIRCUITING REQUIREMENTS WITH TENANT AND/OR FURNITURE DEALERSHIP. ELECTRICAL CONTRATOR TO HARDWIRE FURNITURE SYSTEM TO BUILDING POWER SOURCE. 6. ELECTRICAL CONTRACTOR TO COORDINATE WITH FURNITURE SUPPLIERS BASE FEED. 7. ALL RECEPTACLES REMOVED FROM EXISTING WALLS SHALL HAVE DRYWALL PATCHED AND REPAIRED PRIOR TO INSTALLATION OF WALL FINISHES. 8. WALL MOUNTED OUTLETS TO BE MOUNTED 0 18" A.F.F. UNLESS OTHERWISE NOTED. 9. VERIFY WITH TENANT ANY SPECIFIC SERVER ROOM NEEDS OR EQUIPMENT LAYOUT THAT IS NOT CALLED OUT. ELECTRICAL PLAN NOTES EP1 PROVIDE POWER FOR COPIER. E.C. TO VERIFY POWER REQUIREMENTS. 8 PROVIDE DEDICATED POWER FOR COFFEE MAKER AND MICROWAVE. EP3 PROVIDE BLACK FACEPLATES FOR ALL DEDICATED OUTLETS IN SERVER 104. ELECTRICAL LEGEND SYMBOL DESCRIPTION m = NEW DUPLEX WALL OUTLET T Q NEW QUADRAPLEX WALL OUTLET d)D NEW DEDICATED CIRCUIT OUTLET 6GFI NEW GROUND FAULT INTERUPT CIRCUIT OUTLET 6ISO NEW ISOLATED GROUND CIRCUIT OUTLET 17 NEW TELEPHONE WALL OUTLET (BOX AND PULL STRING) JO NEW JUNCTION BOX v NEW DATA WALL OUTLET (BOX AND PULL STRING) © NEW CABLE OUTLET *D NEW DEDICATED 20AMP 110V SINGLE OUTLET `,� Duke] REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: (317) 808-6000 Fax: (317) 808-6797 ! 18 j cso ArcfllteCture Eroneering Interior$ landscape Architecture Land Surveying Six Parkwood Office 600 East 96th Street, Suite 550 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 I "r = m = " 1*4% C) T Q 0 a J I 000 U� op a t n o o v Certified By: L Number:E201 Of Sheets b Number: A/E Job Number: 22124 6 I Q Z a 0 a J 000 a Qz V � � Q �, J a p ��o U LU DwQ H cl) cr- �o Q U Q Z W W Certified By: L Number:E201 Of Sheets b Number: A/E Job Number: 22124 6 I A.G. EDWARDS SCALE: 1/8"=1'-0" GENERAL NOTES: 1.ALL DUCT GALVANIZED CONSTRUCTION PIAN NOTES: 1.RELOCATE DIFFUSER,TAP AND FLEX REQ'D. 2.RELOCATE DIFFUSER,FLEX MAYBE REQ'D. 3.RELOCATE RETURN GRILLE 5.RELOCATE THERMOSTAT 8.AIR BALANCE UNIT 9.DEMO THIS ITEM 11.CAP 12.NEW DIFFUSER 13.NEW DIFFUSER,TAP AND FLEX REQ'D. 15.NEW RETURN GRILLE 16.NEW RETURN AIR TRANSFER 17.NEW TAP NO SCALE FIRST FLOOR :y 1 i