HomeMy WebLinkAboutBuilding Plans6/12
NOTE
UTILITY LOCATIONS (5ENER, WATER,
ELECTRIC 4 GAS) ARE DETERMINED
BY EACH MUNI G I PAL I TY AND THE
UTILITY COMPANIES. TRINITY
HOMES HA5 NO JURI5DIGTION
GONGERNING THEIR LOCATION
Ix2 OVER Ixb RAKE
Ix4 TRIM
HORIZONTAL SIDING
Ixb TRIM
Ixb FASCIA
Ix4 TRIM
BRICK SOLDIERS
BRICK VENEER
NOTE
FOUNDATION TYPE AND LOT CONDITION5
MAY GAU9E VARIATION BETWEEN ACTUAL
ELEVATION5 AND THE -5E DRANINCG5
12/12
Ix4 CORNER —
(U5E Ixb N/ BRICK
ON FRONT ELEV.)
HORIZONTAL SIDING
Left Elevation
1/8" SCALE
12/12
Ix4 CORNER
(USE 1x6 W/ BRICK
ON FRONT ELEV.) E2
Right Elevation
I/8" SCALE
6/12
I x4 CORNER 12
I
— — ■■■ ■■■ ■■ ■■■ ■■■ ■■■
... ■■■ E.. ■■■ ■■■ ...
111 ...� ...� ■■■ No ■. ■■■ ■.....
■■■ ■■■ .. ... ■■■ ■■■
... ■■■ l■■ ....smo.....
i
I x6'
FRONT ELEVATION -B
1/4" SCALE
6/12
6/12
HORIZONTAL SIDING
PROVIDE GAS LINE TO
FURNACE, WATER HEATER,
& FIREPLACE
Ix4 CORNER
BRICK SOLDIERS
15" PANEL SHUTTER
BRICK SILL
8735
01/04/02 GAD
W
I
I
� I
e
Q
�
Z<
. o
COD0
~Q
z
e
• �4
W
e
LL-
Lu�-
e
J
01/04/02 GAD
1
d
I
I
� I
e
. o
e
• �4
e
• 1
�Y
e
1
NOTE
LOCATION OF SEVER LINE TO BE DIGTATED BY
SEWER LATERAL LOCATION PER PLOT PLAN; 5EE
AREA 50PERINTENDENT IF OPTIMUM LOCATION 15
NOT APPARENT; MIN. 10' BTWN 5EWER LINE AND
WATER LINE; WHERE WATER LOCATION 15
PREDETERMINED, WATER LINE 8 SEWER LINE
CANNOT GRO55
8735
SLAB
01 /04/02 GAD
ELEVATION B
1/4" SCALE
e
' �Y
e
e
•
8
•
• .y
3
' �Y
w
I
0
0
0
N
Cu
M
L6
IT
lb
0
v
Cu
L-
CL d
Q
c
0
M:
0
F --
cc
w
ELL
01
O
ryL
a�
Q,
O
cc
i
0
F-
Y
w
0
3
CD0
z
3
PER 12 MANUFACTURED TRUSSES ® 2'-0" O.G.
ELEV[ OR RAFTERS PER PLAN
FIBER6LA55 5HIN&LE
I5# FELT
-7/I6" WAFER BOARD
R-38 BLONN INSULATION
I x6 FASCIA BOAR I/2" DRYWALL
2"xb" GUTTER BDA 2x4 DBL. TOP PLATE
3/8" R/5 PLYWOOD 2x4 STUD ® 16" O.G.
SOFFIT BOARD R-13 FIBER6LA55 INSULATION
2 "x4" BLOCK
1/2" DRYWALL
1/2" R161D INSULATION
VAPOR BARRIER
GOMP051TE R -VALUE = 19
(TYP.)
51DIN6 PER
SPEC.
2 "x4" SOLE PLATE
3/4" PLYWOOD, GLUED $ NAILED
BAND BOARD a 1/2" I -JOIST #2 5.Y.P. KD 24" O.G.
2"xb" GGA SILL PLATE— j
3/8" x 18" ANCHOR BOLT
8" THICK POURED GONG. FOUNDATION WALL
(HEIGHT PER 5PEG5)
TUFF -N -DRY RIGID INSULATI
4" PERFERATED DRAIN PIP II 4" GONG. SLAB
GRANULAR FILL
\-8"A(b" CONT. POURED GONG. FOOTING
WALL DETAIL W/BASEMENT
GOMPOSITE R VALUE
FOR TYPIGAL WALL GONSTRUGTION
In5lde Air Film
.68
I/2" Drywall
.45
Insulation
13.0
R -Board
3.5
Siding
.7
Air5poce Btwn R -Board
2x4 DBL. TOP PLATE
and Sidnig
5
Outside Air Film
.17
TOTAL
Iq.O
(2).
W 0)
N W
U)
W_
� Z
>�
E I REPLAGE DETAIL
8" GLEARANGE METAL FLUE
8" CLEARANCE METAL FIREPLACE
:OMB. AIR FROM OUTSIDE
O
i
(V
I d
FIBER6LA55 5HIN6LE
15# FELT
l/16WAFER BOARD
I"xb" FASCIA BOARD
2 x(bGUTTER BOARD -
3/8" R/5 PLYWOOD
SOFFIT BOARD
Ix4 FRIEZE BOARD -
2x4 BLOGK
BRICK
2x4 GGA SILL PLA'
(1) COURSE OF
8x16 "L" BLOCK
MANUFACTURED TRUSSES @ 2'-0" O.G.
PER 12 OR RAFTERS PER PLAN
ELEVj
JR ) R-38 BLOWN INSULATION
-1/2" DRYWALL
2x4 DBL. TOP PLATE
2x4 STUD ® 16" O.G.
R-13 FIBERGLASS INSULATION
1/2" DRYWALL
VAPOR BARRIER
2"x4" SOLE PLATE
/-3/4" PLYWOOD, GLUED 8 NAILED
Q 1/2" I -JOIST #2 5.Y.P. RD 24" O.G.
"-- BAND BOARD
&RADE 3/8" x IS" ANCHOR BOLT
I/2" RIGID IN5UL. (R-7.5 MIN) DO NOT USE BEADBOARD
(3) COURSES OF 8"xi6" GONG. BLOCK
�811x16" CONT. POURED GONG. FOOTING
GRANULAR FILL
WALL SECTION ON GRAWL
12 MANUFACTURED TRU55ES ® 2'-0" O.G.
u� OR RAFTERS PER PLAN
EL
FIBEROLAS5 5HIN6LE5
m
15# FELT
7/16" WAFER BOARD
R-38 BLOWN INSULATION
I"xb" FASCIA BOA
1/2" DRYWALL
2"xb" &UTTER BOA
2x4 DBL. TOP PLATE
3/8" R/5 PLYWOOD
2x4 STUD ® 16" O.G.
SOFFIT BOARD
R-13 FIBERGLASS INSULATION
1"x4" FRIEZE BOAR
2x4 BLOCK
I/2" DRYWALL
VAPOR BARRIER
1
1/2" RIGID INSULATION
BRICK VENEER
WOOD BASEBOARD
O GGA BOTTOM PLATE.
4" GONG. SLAB
3/8" x 18" ANCHOR BOLT 6 MIL. VAPOR BARRIER
® 48" O.G. RI61D INSULATION 2"x 48" GOVT.
GRANULAR FILL
"L" GONG. BLOCK
N 8" GONG. BLOCK
12"x24" POURED GONG. FOOTING
WALL SECTION ON SLAB
z
m
Q/
Qz�
•
N��