HomeMy WebLinkAboutDaily Field Report_2018.11.29Contractor: J G Morris Construction
Weather: Cloudy Temperature (°F): 35
Arrival Time: 10:35 Departure Time: 11:31
ATC Rep: Goldman, Raymond
Date: 11/29/2018
Sequential: 1 of 1 Report No: 112918RG1
A. Description of Work:
Building Pad soils placement and compaction.
B. Location Details: Building Pad appox 165 ft. X 65 ft.
C. Tests Performed: Proofrolling Inspection.
D. Equipment and Crew: NA
E. Problems/NonCompliance/Failing Tests
Note that no new discrepancies were reported.
Specs. Available OnSite: Yes No Plans Available OnSite: Yes No
Request for other information; specs./plans, mill certifications, details or manufacturer's literature: NA
Remarks or Comments:
The ATC representative arrived on site at 10:00am as requested by J G Morris Construction. Upon arriving at site, ATC representative
checked in with J G Morris Construction. ATC representative was informed of work requiring testing and inspections.
The area being proofrolled included Building Pad approx. 165 ft. X 65 ft.. The equipment utilized for proofrolling consisted of
Peterbuilt Triangle Dump Truck loaded approx. 65,000 lbs..
No significant pumping or deflection was observed.
Proofrolling Inspection passes.
The area(s) was/were approved.
Any rainfall event that occurs after the proofroll observation may impact the condition of any exposed subgrade. It is our
recommendation that if a rainfall event occurs after the proofroll observation, the soils should be reevaluated by ATC prior to further
work.
Before departing the site, ATC representative notified J G Morris Construction of field inspection results.
✔ ✔
Daily Field Report Report #: DRPO000007
7988 Centerpoint Drive
Suite 100
Indianapolis, IN 46256
Phone: 3175794031
Fax: 3178494278
Client:
J G Morris Construction
., .
., YY .
Project:
170MT00382
Belle Tire, Carmel
Page 1 of 3 2
Before departing the site, ATC representative notified J G Morris Construction of field inspection results.
Upload Image/PDF: Image/PDF Description:
Building Pad approx. 165 ft. X 65 ft.
Daily Field Report Report #: DRPO000007
7988 Centerpoint Drive
Suite 100
Indianapolis, IN 46256
Phone: 3175794031
Fax: 3178494278
Client:
J G Morris Construction
., .
., YY .
Project:
170MT00382
Belle Tire, Carmel
Page 2 of 3 2