HomeMy WebLinkAbout25 Shadow Wood LAYOUTHTU26HTU26HTU26HTU26HTU26HTU262x4 Nailer for Decking
Comment 1
MUS26
MUS26
MUS26
MUS26
MUS26
MUS26
MUS26
MUS26
MUS26 HTU26Add a 2x4 plate to wall to
raise 2x8 beam up 1-1 /2" to
match Print Elevation
Comment 2 Stick Frame Dormer in Field MUS26
MUS26
GE05
GE02
T03
GE07
TG02GE03T13T11TG03T17 GE04T05 GE01TG01 GE06T04
J02V10
V11
V12
V13
V14
V15
V01
V02
V03
V04
V18V05
V06
V07
V08
V16 V17V19 V09T12(2) T16(3)T19(6)
J01(4)
T01(4)
T10(3) T10(3)T02(2)T06A(5)T06(4) T04A(2)T15(5) 45-00-0066-11-004-00-00 56-11-00 6-00-0066-11-0020-11-00 12-00-00 7-01-00 13-11-00
63-11-00
53-11-00
2-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-00 2-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-09-08 2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
1-10-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
19-11-00 20-01-00 13-11-00
16-00-00 4-09-047-06-08
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00 19-11-00 10-00-00 2-00-00 2-00-002-00-002-00-002-00-002-00-0010-00-00 2-00-00 A- H2.5A A - LTHJR B- HGUS26-2 B - LUS24 C- HGUS26-2-2 C - LUS26-2 D- HGUS28-2 D - LUS410 E- HTU26 E - MUS26 F - LTHJL F -THA422-2 PULTE HOMES25 Shadow Wood - Croix - CT2HHANGER SCHEDULE QTY DESCRIPTION SYM QTY DESCRIPTION ROOF LOADINGTCLL 25 PSFTCLS 0 PSFTCLD 10 PSFBCLL 10 PSFBCLD 10 PSFWIND SPEED 90 MPHCODE: IRC 2006Address: Salesperson:Scale: Quote Number:B18803353 Drawn by:Katherine SelvaDate: 11/13/2018 Lot Number:25 Designed by: Katherine SelvaTRUSS PLACEMENT GUIDE
CUSTOMER:JOB NAME & MODEL:NOTES:
DO NOT CUT OR MODIFY TRUSSES.
TRUSSES ARE SPACED 24" ON CENTER UNLESS NOTED OTHERWISE.
REFER TO THE INDIVIDUAL TRUSS DESIGN DRAWINGS FOR THE LOCATION OF
LATERAL BRACING AND MULTY-PLY CONNECTION REQUIREMENTS.
PER ANSI TPI 1-2002 THE TRUSS ENGINEER IS RESPONSIBLE FOR TRUSS TO TRUSS
CONECTIONS AND TRUSS PLY TO PLY CONNECTIONS. THIS PLACEMENT PLAN
RECOMMENDS TRUSS TO BEARING CONNECTIONS AND TRUSS TO BEAM
CONNECTIONS WHICH SHALL BE REVIEWED BY THE BUILDING DESIGNER TO
RESOLVE ALL ROOF FORCES ADEQUATELY TO THE FOUNDATION.
ALL TRUSS TIES TO BE INSTALLED BEFORE
O.S.B. IS APPLIED TO ROOF
DO NOT CUT TRUSSES! TRUSSES CUT BY ANY TRADE / SUB-CONTRACTOR WITHOUT FIRST RECEIVING PERMISSIONAND DIRECTION FROMPROBuild, (317) 834 5380, SHALL BE CONTRACTOR / BUILDER RESPONSIBILITY! NO EXCEPTIONS3D VIEW 1
3D VIEW 2
12/03/18
Mike Sheeks