Loading...
HomeMy WebLinkAboutA000.3SCALE:FRONT ELEVATION1/4" = 1'-0"- \A1;1'-1" 1012 1012 3:12 SHINGLES PERSUB. SPECS. 9" CROSSHEAD14" PANELED SHUTTERS (TYP.) FYPON LV12x36 OR EQUIV., TYP. SHINGLES PERSUB. SPECS. STONE VENEERPER SPECS9" CROSSHEAD OPT. STANDING SEAM METAL ROOF W/ SEAMS @ 18" O.C. 4" TRIM SURROUND ON DOOR STONE VENEER PER SPECS \A1;2'-11{\H0.75x;\S5#8;}" \A1;3'-6" VERTICAL SIDING PER SPECS STONE SILL6" TRIM BOARD (TYP.)DRIP CAP 9" CROSSHEAD OVER DOOR \A1;2'-11{\H0.75x;\S5#8;}" C L 10123:12 20202020 GABLE VENT PER SPEC SHINGLES PER SUB SPECS.SHINGLES PER SUB SPECS.FIXEDFIXED \A1;24'-6{\H0.75x;\S1#2;}"\A1;6'-0" \A1;8'-1{\H0.75x;\S1#8;}"\A1;7'-2{\H0.75x;\S7#8;}" ROOF W/\POPT. LOFT \A1;9'-1{\H0.75x;\S1#8;}"\A1;OPT. 10'-1{\H0.7x;\S1#8;}" \A1;8'-2{\H0.75x;\S7#8;}"\A1;9'-2{\H0.7x;\S7#8;}" @ OPT. 10' PL. WINDOW HEIGHT 1st FLR LINE PLATE HEIGHT SECOND FLOOR PLATE (OPT. LOFT)WINDOW HDR. HGT. TOP OF FOUNDATION\A1;4'-6" A.F.F. 9" CROSSHEAD4" TRIM BOARD4" SILL (SEE PORCH DETAIL)VERTICAL SIDING PER SPECS SCALE:REAR ELEVATION1/8" = 1'-0"- OPT. BRICK HEIGHT SCALE:LEFT ELEVATION1/8" = 1'-0"- OPT. DOOR\PPER PLAN \A1;8'-4{\H0.75x;\S3#8;}"\A1;HDR. HGT. @ 4010 OPT. BRICK HEIGHT 127 127 SCALE:ROOF PLAN1/8" = 1'-0"- ROOF AREA"A"3104 SQ. FT. 10:12 10:12 \A1;10'-0"10:1210:12 5:12 5:12 OPT. POT VENTS \A1;14'-0"5:12 10:12 3:12 3:12 OPT. GUTTER AND DOWNSPOUTS OPT 7:12 OPT 7:12 OPT 7:12 5:12OPT 7:12 5:12OPT 7:12 \A1;8'-0"\A1;8'-0" \A1;8'-0" ELEVATION CT2H ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3104 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.14 5.17 5.08 49.73 12 0 AT EAVE 6.21 5.17 5.14 50.27 0 74.00 TOTAL (MIN)10.35 10.35 10.22 100.00 3 HIGH - RIDGE VENT 4.14 5.17 6.00 53.87 0 0 48.00 AT EAVE 6.21 5.17 5.14 46.13 0 74.00 TOTAL (MIN)10.35 10.35 11.14 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE SCALE:RIGHT ELEVATION1/8" = 1'-0"- \A1;1'-1"\A1;1'-1" 512 \A1;2'-0"WINDOW HEIGHT 1st FLR LINE CEILING HEIGHT STONE VENEER PER SPECS6" CORNER BD. ON FRONT ELEV. &4" ON SIDES& REAR ELEV.OPT. BRICK HEIGHT SECOND FLOOR PLATE (OPT. LOFT) \A1;8'-1{\H0.75x;\S1#8;}"\A1;7'-2{\H0.75x;\S7#8;}" WINDOW HDR. HGT. OPT. WINDOWS\PPER PLAN 127ROOF W/\POPT. LOFT 127 \A1;9'-1{\H0.75x;\S1#8;}"\A1;OPT. 10'-1{\H0.7x;\S1#8;}" \A1;8'-2{\H0.75x;\S7#8;}"\A1;9'-2{\H0.7x;\S7#8;}" @ OPT. 10' PL.TOP OF FOUNDATION \A1;1'-1"1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2017 RICK STARKEY06/07/2013 GARAGE LEFT Croix 1993.301 -- 08/01/2017 PLOTTED: October 6, 2017 / Mark Muurisepp / 1993-CROIX-CZ-BAS2-EL-CT2H.DWG A3 CT2H-2GS.1Cottage 2H - Slab2 Car Front Entry w/ Golf Cart Storage AreaFront, Side and Rear Elevations, Roof Plan and Ventilation Schedulestone wainscoting in shadow 6:12 in shadow wood 12" overhangs 4 sides 12/03/18 Mike Sheeks