HomeMy WebLinkAbout18100001 State Release FULL ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Project numberRelease date CONSTRUCTION DESIGN RELEASE 40319910/26/18 State Form 41191 (R9/5-98) Construction typeOccupancy classification Report Printed on:December 20, 2018 I-B, SPKR-2, A-2 Scope of release ARCHELECFAMECH Indiana Department of Homeland Security PLUMSTR DIVISION OF FIRE & BUILDING SAFETY Type of release PLAN REVIEW DIVISION 402 W. Washington St., Room E245 Standard Indianapolis, IN 46204 Available At Your Local Licence Branch Project name SUPPORT HOOSIER SAFETY Hotel Carmichael at City Center To: Owner / Architect / Engineer GSB Inc Street address Ronald G. Smith AR19800135 One Carmel Square 3555 NW 58th St Ste 700W Oklahoma CityOK73112 CityCounty CARMELHAMILTON Fax & e-mail:4058489783,rsmith@gsb-inc.com The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. 14BThis project has been reviewed under the 2014 Indiana Building Code. A2An elevator installation permit shall be obtained from the Elevator Safety Division in accordance with IESC (675 IAC 21-1-1). Please visit: http://www.in.gov/dhs/2374.htm 9B1807BSmoke detectors shall be installed on elevator lobby ceilings which shall activate the operational functions of the elevator in accordance with Section 1807(h)2, IBC (675 IAC 13-2.l). 4G0603AE1Detailed plans and specifications of the fire suppression system shall be filed with the required application and appropriate fees in accordance with 675 IAC 12-6-3(a), 675 IAC 12-6-7(g)(17), and 675 IAC 13-1-25. (N.F.P.A. 13R) 14B0907The fire alarm system shall be designed as specified in Section 907, IFC, and N.F.P.A. 72, in accordance with Section 907, IBC (675 IAC 13-2.6). 14W09077Upon completion of the installation of the fire alarm system, a satisfactory test of the entire system shall be made. All functions of the system or alteration shall be tested in accordance with Section 907.7, IFC (675 IAC 22-2.5). 14B100815There shall be a floor or landing on each side of a door in accordance with Section 1008.1.5, IBC (675 IAC 13-2.6). 14B10107Ramps shall have landings at the bottom and top of each ramp, points of turning, entrance, exits and at doors in accordance with Section 1010.7, IBC (675 IAC 13-2.6). 14B12032Attic ventilation shall be provided in accordance with Section 1203.2, IBC (675 IAC 13-2.6). 14B12092A 20-inch by 40-inch attic access opening shall be provided in accordance with Section 1209.2, IBC (675 IAC 13-2.6). 14B24064Safety glazing shall be provided in hazardous locations in accordance with Section 2406.4, IBC (675 IAC 13-2.6). Page1/2 ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report 14B11092Each toilet room and bathing room shall be handicapped accessible in accordance with Section 1109.2, IBC (675 IAC 13-2.6). (Clear turning radius, Door Swing, Grab Bars, Fixture Clearances, Fixture Mounting Heights, Shower/Bathtub seats) 9E2108Commercial bathrooms, kitchens, and rooftops shall be provided with GFCI protection in accordance with Section 210.8, IEC (675 IAC 17-1.8). 9E11027BWhere electric equipment is likely to be exposed to physical damage, enclosures or guards shall be installed to prevent damage in accordance with Section 110.27(B), IEC (675 IAC 17-1.8). 5D0312BRequired guardrails shall have intermediate rails or ornamental closures that do not allow passage of a 4-inch diameter sphere in accordance with Section R312.2, IRC (675 IAC 14-4.3). 14M0920 Suspended-type unit heaters shall be installed and supported in accordance with Section 920, IMC (675 IAC 18-1.6). 10C5434AVestibules shall have self-closing interior and exterior doors having a minimum distance between them of not less than 7 ft. when in the closed position in accordance with Section 5.4.3.4, IECC (675 IAC 19-4). ARELPursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from compliance with all applicable rules of the commission, even if items contrary to those rules appear in the plans and specifications that have been filed with the division. The owner is responsible for correcting any and all areas of noncompliance even if they are discovered subsequent to the issuing of this design release. Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above - stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will be final, and you must comply with its requirements. Code review officialMICHAEL ANDERSON Director, Division of Fire and Building Safety mianderson@dhs.in.gov Address (name,title of local official,street,city,state and ZIP code DEPT OF COMMUNITY SERVICE JIM BLANCHARD ONE CIVIC SQUARE CARMEL,IN46032 Fax & e-mail: 3175712499,jblanchard@carmel.in.gov Page2/2