Loading...
HomeMy WebLinkAboutC2.1 - Utility PlanTOPOGRAPHIC & BOUNDARY NOTE ALL EXISTING HORIZONTAL AND VERTICAL INFORMATION HAS BEEN SHOWN PER AN ALTA/NSPS LAND TITLE SURVEY PREPARED BY SEA GROUP, LLC. DATED 05/24/2018; THEREFORE, CIVIL SITE GROUP, INC. CANNOT BE HELD RESPONSIBLE IF ACTUAL HORIZONTAL AND VERTICAL DATA IS DIFFERENT FROM THAT SHOWN ON THESE PLANS. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO COMMENCING WITH CONSTRUCTION. THESE DRAWINGS REFLECT ABOVE GROUND INDICATIONS OF EXISTING UTILITIES. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. OWNER: DERMATOLOGY, INC. 3755 EAST 82nd STREET, STE. 75 INDIANAPOLIS, IN 46240 ATTN: AMY SUMMERS (317) 410-0056 ENGINEER: CIVIL SITE GROUP, INC. 160 WEST CARMEL DRIVE SUITE 240 CARMEL, INDIANA 46032 (317) 810-1677 EXISTING SANITARY MANHOLE T.C.=842.95 INV.=834.95 (S-10" PVC) INV.=834.95 (N-10" PVC) EXISTING IRRIGATION VALVE SURVEYOR: SEA GROUP, LLC. 494 GRADLE DRIVE CARMEL, INDIANA 46032 (317) 844-3333 ARCHITECT: ENVIROSPACE, INC. ATTN: CANDACE BERGER 645 BLOOR LANE ZIONSVILLE, IN 46077 (317) 873-9950 CONNECT TO EXISTING 6" SAN. LAT. STUB (PER C.T.R.W.D. STANDARDS) 10f LF of EXISTING 6" SANITARY LATERAL (CONTRACTOR TO FIELD VERIFY DEPTH & LOCATION PRIOR TO COMMENCING WITH CONSTRUCTION) EXISTING SANITARY MANHOLE T.C.=842.84 INV.=836.34 (W-10" PVC) INV.=836.34 (N-10" PVC) —SAN — SANITARY LATERAL NOTE UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPER'S RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OR THE PROPOSED RIGHT-OF-WAY LINE. \S74 —FBOP CROSS -HATCH DENOTES 0.05 ACRE BMP EASEMENT —FBOP FBOP CONTRACTOR NOTE NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 1 r/1Nrn1n. LAKEFRONT COURT -------- —STM —STM -STM sTM .... STM —STM STM STM STM — FBOP� EX. WATER MAIN WWj�y VTR FBOP W.TR WTR WTR WTR WTR WTR WTR V O rig] EX PBS,,—,, . .... . G G G G — --------------- 2" WATER SERVICE LINE TAP w/ CURB WTR STOP VALVE & FULL CIRCLE CLAMP COM PER CARMEL UTILITIES STD CW4-1 —FBOP UGE STM SAN E E T T W W— G G C.O. ISI A AI AI/'NTrC%. PROPERTY BOUNDARY RIGHT-OF-WAY EASEMENT NORTH PROPOSED CONCRETE 20 0 10 20 PROPOSED STORM SEWER ( IN FEET ) PROPOSED STORM STRUCTURE 1 inch= 20 ft. UTILITY CROSSING (EXISTING UTILITY DEPTH UNKNOWN / CONTRACTOR TO FIELD VERIFY PRIOR TO COMMENCING WITH CONSTRUCTION) ROOF DRAIN EXISTING WATER LINE EXISTING COMMUNICATION LINE EXISTING FIBER OPTIC LINE EXISTING UNDERGROUND ELECTRIC LINE EXISTING STORM SEWER EXISTING STORM SEWER PROPOSED ELECTRIC SERVICE PROPOSED TELECOM SERVICE PROPOSED WATER SERVICE PROPOSED GAS SERVICE PROPOSED SANITARY LATERAL WITH CLEANOUT (SEE DETAIL 17/C10.1) SPLIT 1" INTERIOR SET METER ASSEMBLIES PER CARMEL UTILITIES STDS. / OBACKFLOW PREVENTER TO BE FIRST CONNECTION DOWNSTREAM OF METER TREE (CONTRACTOR TO VERIFY ADEQUATE PRESSURE & FLOW PRIOR TO COMMENCING WITH CONSTRUCTION) UX UTILITY CROSSING CC CONCRETE CRADLE REQUIRED SITE LIGHTING NOTE IRRIGATION NOTE UTILITY VALVE NOTE UTILITY NOTES 1. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO THEIR PHASE OF WORK. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATIONS FOR EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED. 2. STANDARD SPECIFICATIONS FOR THE LOCAL GOVERNING AGENCY SHALL APPLY FOR ALL SANITARY SEWERS, STORM SEWERS, AND WATER MAINS. 3. ANY PART OF THE SANITARY OR STORM SEWER TRENCHES RUNNING UNDER PAVED AREAS TO BE BACKFILLED WITH GRANULAR MATERIAL. 4. ALL WATER SERVICE / FIRE LINES ARE REQUIRED TO HAVE A 54" MINIMUM COVER OVER TOP OF PIPE. ALL WATER/SANITARY LINE CROSSINGS MUST MAINTAIN 18" VERTICAL SEPARATION BETWEEN OUTSIDE OF PIPES PER INDIANA STATE DEPARTMENT OF HEALTH. 5. STERILIZATION OF WATER MAIN SHALL BE IN ACCORDANCE WITH STATE BOARD OF HEALTH REQUIREMENTS. (APPLIES TO COMMERCIAL ONLY) 6. CONTRACTOR RESPONSIBLE TO INSTALL ALL UNDERGROUND CONDUIT PER UTIITY COMPANY'S SPECIFICATIONS. 7. CONTRACTOR RESPONSIBLE FOR RESTORATION TO ALL AREAS AFFECTED DURING CONSTRUCTION. REFER TO THE CITY OF NOBLESVILLE STANDARDS FOR RESTORATION REQS. 8. CONTRACTOR TO LOCATE ALL EXISTING UTLITIES AT ANY PROPOSED CROSSING AND PROVIDE EXISTING TOP OF PIPE ELEVATIONS WITHIN 10 DAYS OF NOTICE TO PROCEED. PROVIDE CONCRETE CRADLE AS REQUIRED FOR ANY VERTICAL SEPARATION LESS THAN 18 INCHES. UTILITY CONTACTS Natural Gas: Telephone: CATV: ' Vectren Energy AT&T Brighthouse Networks I I I I ` :i. • t: Joanie Clark Steve Krebs Jason Kirkman *. (317) 776-5532 (317) 252-4275 (317) 632-9077 x291 jlclark@Vectren.com SK4986@att.com jason.kirkman@mybrlghthouse.com _ I I Sanitary Sewer: Fire Service: Water: ow what's helnW. Q111 before you dig.I I — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Clay Township Regional Waste District Office of Fire Chief, Fire Station #1 Carmel City Utilities _--I-- ------------------------------------------------- Ryan Hartman David Haboush John Duffy — — — — — — — — — — — — — — — — — — — — — — — — — — — — 10701 N. College Avenue, Ste. A Two Civic Square 760 Third Avenue SW Indianapolis, IN 46280 Carmel, IN 46032 Carmel, IN 46032 UTILITY LOCATE NOTE i°OMS°pM_CON— I °°M_ —STM STM STM (317) 844-9200 ext. 203 (317) 571-2600 (317) 632-9077 �$T.. I—STM STM STM —SIM-�01aF�—�5 ^�"�-51�� -���6� COM 5C0M—_ CpM STM S COM S= , dhaboush@carmel.in.gov 4NA 811 FAILED TO LOCATE ALL EXISTING I I — °°M— 35 REGULATED DRAIN EASEMENT y� Drainage: Electric: ITIES ON AND/OR SURROUNDING THE SUBJECT THEREFORE, CONTRACTOR IS RESPONSIBLE To I 30' UTILITY EASEMENT & REAR YARD SETBACK ❑ Carmel Engineering Streets: Duke Energy ATE AND FIELD VERIFY ANY EXISTING UTILITIESGoy I I E Alex Jordan or John Thomas Carmel Street Department Shirley Hunter DRE COMMENCING WITH CONSTRUCTION. CIVIL X — X—X 1 Civic Square Dave Klingensmith 16475 Southpark Dr. GROUP, INC. CANNOT BE HELD RESPONSIBLE) Carmel, IN 46032 3400 West 131st Street Westfield, IN 46074 HE PROPOSED IMPROVEMENTS INTERFERE WITH EXISTING UTILITY INFORMATION NOT SHOWN ON (317) 571-2441 Westfield, IN 46074 (317) 896-6721 SE PLANS. gduncan@carmel.in.gov (317) 733-2001 shirley.hunter@duke-energy.com U z L0 (L C� uC\1 o 00 W � o Q C/) Z:1;4- 0� .N w� OLX �LV �o �� (0� W�� I QID wQ IW—E=0 L0 00 L0 ,_, 10 1� 0 CY) O V � G .`% G L ESS P . N ° No s PE10403858 e = STATE OF 00X,/ P,P O 1 L `, DATE: 07/20/2018 DWN BY: KPB CHKD. BY: EAG SCALE: 1 to20' DATE: 07/20/18 N N�M `, J W O a� O� I� VO� C8 a O O V) O o O H� �W OLo PROJECT NUMBER DER. 001 DRAWING NUMBER C2.1 SHEET 4 OF 15 =