HomeMy WebLinkAboutDER001.C2.1TOPOGRAPHIC & BOUNDARY NOTE
ALL EXISTING HORIZONTAL AND VERTICAL INFORMATION
HAS BEEN SHOWN PER AN ALTA/NSPS LAND TITLE
SURVEY PREPARED BY SEA GROUP, LLC. DATED
05/24/2018; THEREFORE, CIVIL SITE GROUP, INC.
CANNOT BE HELD RESPONSIBLE IF ACTUAL HORIZONTAL
AND VERTICAL DATA IS DIFFERENT FROM THAT SHOWN
ON THESE PLANS. CONTRACTOR IS RESPONSIBLE FOR
FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR
TO COMMENCING WITH CONSTRUCTION. THESE
DRAWINGS REFLECT ABOVE GROUND INDICATIONS OF
EXISTING UTILITIES. THE SURVEYOR MAKES NO
GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN
COMPRISE ALL SUCH IN THE AREA, EITHER IN SERVICE
OR ABANDONED. THE SURVEYOR FURTHER DOES NOT
WARRANT THAT THE UNDERGROUND UTILITIES SHOWN
ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HE
DOES CERTIFY THAT THEY ARE LOCATED AS
ACCURATELY AS POSSIBLE FROM THE INFORMATION
AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY
LOCATED THE UNDERGROUND UTILITIES.
OWNER:
DERMATOLOGY, INC.
3755 EAST 82nd STREET, STE. 75
INDIANAPOLIS, IN 46240
ATTN: AMY SUMMERS
(317) 410-0056
ENGINEER:
CIVIL SITE GROUP, INC.
160 WEST CARMEL DRIVE
SUITE 240
CARMEL, INDIANA 46032
(317) 810-1677
EXISTING SANITARY MANHOLE
T.C.=842.95
INV.=834.95 (S-10" PVC)
INV.=834.95 (N-10" PVC)
EXISTING
IRRIGATION VALVE
SURVEYOR:
SEA GROUP, LLC.
494 GRADLE DRIVE
CARMEL, INDIANA 46032
(317) 844-3333
ARCHITECT:
ENVIROSPACE, INC.
ATTN: CANDACE BERGER
645 BLOOR LANE
ZIONSVILLE, IN 46077
(317) 873-9950
CONNECT TO EXISTING 6" SAN. LAT. STUB
(PER C.T.R.W.D. STANDARDS)
10f LF of EXISTING 6" SANITARY LATERAL
(CONTRACTOR TO FIELD VERIFY DEPTH & LOCATION
PRIOR TO COMMENCING WITH CONSTRUCTION)
EXISTING SANITARY MANHOLE
T.C.=842.84
INV.=836.34 (W-10" PVC)
INV.=836.34 (N-10" PVC)
—SAN —
SANITARY LATERAL NOTE
UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE
THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE
RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT
IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE
DEVELOPER'S RESPONSIBILITY TO RESOLVE WITH THE UTILITY.
EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN
ONE FOOT OR THE PROPOSED RIGHT-OF-WAY LINE.
\S74
—FBOP
CROSS -HATCH
DENOTES 0.05 ACRE
BMP EASEMENT
—FBOP FBOP
CONTRACTOR NOTE
NO EARTH DISTURBING ACTIVITY MAY COMMENCE
WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT.
1 r/1Nrn1n.
LAKEFRONT COURT --------
—STM
—STM -STM sTM
.... STM —STM
STM STM STM —
FBOP� EX. WATER MAIN
WWj�y
VTR FBOP W.TR WTR WTR WTR WTR WTR WTR V O rig]
EX PBS,,—,, . ....
. G G G G —
---------------
2" WATER SERVICE LINE TAP w/ CURB WTR
STOP VALVE & FULL CIRCLE CLAMP COM
PER CARMEL UTILITIES STD CW4-1 —FBOP
UGE
STM
SAN
E
E
T
T
W
W—
G
G
C.O.
ISI A AI AI/'NTrC%.
PROPERTY BOUNDARY
RIGHT-OF-WAY
EASEMENT
NORTH
PROPOSED CONCRETE 20 0 10 20
PROPOSED STORM SEWER ( IN FEET )
PROPOSED STORM STRUCTURE 1 inch= 20 ft.
UTILITY CROSSING (EXISTING UTILITY DEPTH
UNKNOWN / CONTRACTOR TO FIELD VERIFY PRIOR
TO COMMENCING WITH CONSTRUCTION)
ROOF DRAIN
EXISTING WATER LINE
EXISTING COMMUNICATION LINE
EXISTING FIBER OPTIC LINE
EXISTING UNDERGROUND ELECTRIC LINE
EXISTING STORM SEWER
EXISTING STORM SEWER
PROPOSED ELECTRIC SERVICE
PROPOSED TELECOM SERVICE
PROPOSED WATER SERVICE
PROPOSED GAS SERVICE
PROPOSED SANITARY LATERAL WITH
CLEANOUT (SEE DETAIL 17/C10.1)
SPLIT 1" INTERIOR SET METER ASSEMBLIES PER CARMEL UTILITIES STDS. /
OBACKFLOW PREVENTER TO BE FIRST CONNECTION DOWNSTREAM OF METER
TREE (CONTRACTOR TO VERIFY ADEQUATE PRESSURE & FLOW PRIOR TO
COMMENCING WITH CONSTRUCTION)
UX UTILITY CROSSING
CC CONCRETE CRADLE REQUIRED
SITE LIGHTING NOTE
IRRIGATION NOTE
UTILITY VALVE NOTE
UTILITY NOTES
1. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO
VERIFY ALL EXISTING UTILITIES AND CONDITIONS
PERTAINING TO THEIR PHASE OF WORK. IT SHALL ALSO BE THE
CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF
THE VARIOUS UTILITIES FOR PROPER STAKE LOCATIONS FOR
EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR
SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF
ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE
PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR
RESUMED.
2. STANDARD SPECIFICATIONS FOR THE LOCAL GOVERNING
AGENCY SHALL APPLY FOR ALL SANITARY SEWERS, STORM
SEWERS, AND WATER MAINS.
3. ANY PART OF THE SANITARY OR STORM SEWER TRENCHES
RUNNING UNDER PAVED AREAS TO BE BACKFILLED WITH
GRANULAR MATERIAL.
4. ALL WATER SERVICE / FIRE LINES ARE REQUIRED TO HAVE A 54"
MINIMUM COVER OVER TOP OF PIPE. ALL WATER/SANITARY LINE
CROSSINGS MUST MAINTAIN 18" VERTICAL SEPARATION BETWEEN
OUTSIDE OF PIPES PER INDIANA STATE DEPARTMENT OF HEALTH.
5. STERILIZATION OF WATER MAIN SHALL BE IN ACCORDANCE
WITH STATE BOARD OF HEALTH REQUIREMENTS.
(APPLIES TO COMMERCIAL ONLY)
6. CONTRACTOR RESPONSIBLE TO INSTALL ALL UNDERGROUND
CONDUIT PER UTIITY COMPANY'S SPECIFICATIONS.
7. CONTRACTOR RESPONSIBLE FOR RESTORATION TO ALL AREAS
AFFECTED DURING CONSTRUCTION. REFER TO THE
CITY OF NOBLESVILLE STANDARDS FOR RESTORATION REQS.
8. CONTRACTOR TO LOCATE ALL EXISTING UTLITIES AT ANY
PROPOSED CROSSING AND PROVIDE EXISTING TOP OF PIPE
ELEVATIONS WITHIN 10 DAYS OF NOTICE TO PROCEED.
PROVIDE CONCRETE CRADLE AS REQUIRED FOR ANY VERTICAL
SEPARATION LESS THAN 18 INCHES.
UTILITY CONTACTS
Natural Gas: Telephone: CATV:
' Vectren Energy AT&T Brighthouse Networks
I I I I ` :i. • t: Joanie Clark Steve Krebs Jason Kirkman
*.
(317) 776-5532 (317) 252-4275 (317) 632-9077 x291
jlclark@Vectren.com SK4986@att.com jason.kirkman@mybrlghthouse.com
_ I I Sanitary Sewer: Fire Service: Water:
ow what's helnW. Q111 before you dig.I I — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Clay Township Regional Waste District Office of Fire Chief, Fire Station #1 Carmel City Utilities
_--I-- ------------------------------------------------- Ryan Hartman David Haboush John Duffy
— — — — — — — — — — — — — — — — — — — — — — — — — — — — 10701 N. College Avenue, Ste. A Two Civic Square 760 Third Avenue SW
Indianapolis, IN 46280 Carmel, IN 46032 Carmel, IN 46032
UTILITY LOCATE NOTE i°OMS°pM_CON—
I °°M_ —STM STM STM (317) 844-9200 ext. 203 (317) 571-2600 (317) 632-9077
�$T.. I—STM STM STM —SIM-�01aF�—�5 ^�"�-51�� -���6� COM 5C0M—_ CpM STM S COM S= , dhaboush@carmel.in.gov
4NA 811 FAILED TO LOCATE ALL EXISTING I I — °°M— 35 REGULATED DRAIN EASEMENT y� Drainage: Electric:
ITIES ON AND/OR SURROUNDING THE SUBJECT
THEREFORE, CONTRACTOR IS RESPONSIBLE To I 30' UTILITY EASEMENT & REAR YARD SETBACK ❑ Carmel Engineering Streets: Duke Energy
ATE AND FIELD VERIFY ANY EXISTING UTILITIESGoy I I E Alex Jordan or John Thomas Carmel Street Department Shirley Hunter
DRE COMMENCING WITH CONSTRUCTION. CIVIL X — X—X 1 Civic Square Dave Klingensmith 16475 Southpark Dr.
GROUP, INC. CANNOT BE HELD RESPONSIBLE) Carmel, IN 46032 3400 West 131st Street Westfield, IN 46074
HE PROPOSED IMPROVEMENTS INTERFERE WITH
EXISTING UTILITY INFORMATION NOT SHOWN ON (317) 571-2441 Westfield, IN 46074 (317) 896-6721
SE PLANS. gduncan@carmel.in.gov (317) 733-2001 shirley.hunter@duke-energy.com
U
z
L0 (L
C�
uC\1
o
00
W � o
Q
C/) Z:1;4-
0� .N
w�
OLX
�LV �o
�� (0�
W�� I
QID
wQ IW—E=0
L0 00
L0 ,_,
10
1� 0
CY) O
V �
G
.`% G L ESS
P
. N
°
No
s PE10403858 e =
STATE OF
00X,/ P,P
O 1 L `,
DATE: 07/20/2018
DWN BY: KPB
CHKD. BY: EAG
SCALE: 1 to20'
DATE: 07/20/18
N
N�M
`, J
W O
a�
O�
I�
VO�
C8 a
O
O
V) O
o
O
H�
�W
OLo
PROJECT NUMBER
DER. 001
DRAWING NUMBER
C2.1
SHEET 4 OF 15
=