HomeMy WebLinkAbout332675 11/21/18 CITY OF CARMEL, INDIANA VENDOR: 131135
ONE CIVIC SQUARE HOOSIER FIRE EQUIPMENT INC CHECK AMOUNT: $*****3,332.50*
CARMEL, INDIANA 46032 4009 MONTDALE PARK DRIVE CHECK NUMBER: 332675
9MiTON VALPARAISO IN 46383 CHECK DATE: 11/21/18
DEPARTMENT ACCOUNT PO NUMBER INVOICE NUMBER AMOUNT DESCRIPTION
1120 4237000 0101419IN 232.00 REPAIR PARTS
1120 4351000 101395IN 3,100.50 AUTO REPAIR & MAINTEN
VOUCHER NO. WARRANT NO. Prescribed by State Board of Accounts City Form No.201(Rev.1995)
Vendor# 131135 ALLOWED 20 ACCOUNTS PAYABLE VOUCHER
HOOSIER FIRE EQUIPMENT INC IN SUM OF$ CITY OF CARMEL
4009 MONTDALE PARK DRIVE An invoice or bill to be property itemized must show:kind of service,where performed,dates service
rendered,by whom,rates per day,number of hours,rate per hour,number of units,price per unit,etc.
VALPARAISO, IN 46383
Payee
$3,332.50
Purchase Order#
ON ACCOUNT OF APPROPRIATION FOR
Carmel Fire Terms
Date Due
PO# ACCT# DATE INVOICE# DESCRIPTION
DEPT# INVOICE# Fund# AMOUNT Board Members DEPT# FUND# (or note attached invoice(s)or bill(s)) AMOUNT
0101419-IN 42-370.00 $232.00 1 hereby certify that the attached invoice(s),or 11/18/18 0101419-IN Misc.Parts $232.00
1120 101 1120 101
101395-IN 43-510.00 $3,100.50 bill(s)is(are)true and correct and that the 11/18/18 101395-IN Pump Test-340,341,342,343,344,345, $3,100.50
1120 101 materials or services itemized thereon for 1120 101 346,349,L340,
which charge is made were ordered and
received except
Sunday, November 18,2018
David Haboush
Fire Chief
I hereby certify that the attached invoice(s),or bill(s),is(are)true and correct and I have
audited same in accordance with IC 5-11-10-1.6
,20—
Cost
20Cost distribution ledger classification if claim paid motor vehicle highway fund. Clerk-Treasurer
Page: 1
Invoice
Hoosier Fire Equipment,Inc. Invoice Number: 0101419-IN
4009 Montdale Park Drive Invoice Date: 11/8/2018
Valparaiso,Indiana 46383
(219)462-1707
Order Number: 0124421
Order Date 11/3/2018
Salesperson: 0400 R.W.Pressel
Customer Number: CARM01
Sold To: Ship To:
Carmel Fire Department Carmel Fire Department
2 Civic Square 4925 East 106th Street
Carmel,IN 46032-7543 Carmel,IN 46032-7543
Confirm To:
Customer P.O. Ship VIA F.O.B. Terms
UNITED PARCEL SHIPPING POINT Net 10
Item Code Unit Ordered Shipped Back Ordered Price Amount
/SORDER EACH 3.00 3.00 0.00 72.00 216.00
#FC503F-FIRE RESEARCH FOCUS GLASS LENS&GASKET
Net Invoice: 216.00
Less Discount: 0.00
Freight: 16.00
Sales Tax: 0.00
Invoice Total: 232.00
Page: 1
Invoice
Hoosier Fire Equipment,Inc. Invoice Number: 0101395-IN
4009 Montdale Park Drive Invoice Date: 11/6/2018
Valparaiso,Indiana 46383
(219)462-1707
Order Number:
Order Date
Salesperson: 0000 House
Customer Number: CARM01
Sold To: Ship To:
Carmel Fire Department Carmel Fire Department
2 Civic Square 2 Civic Square
Carmel,IN 46032-7543 Carmel,IN 46032-7543
Confirm To:
Customer P.O. Ship VIA F.O.B. Terms
Net 10
Item Code Unit Ordered Shipped Back Ordered Price Amount
/SERVICE EACH 1.00 1.00 0.00 344.50 344.50
ANNUAL PUMP TESTING ON CUSTOMER'S 2003 KME PUMPER(SN:5340)
/SERVICE EACH 1.00 1.00 0.00 344.50 344.50
ANNUAL PUMP TESTING ON CUSTOMER'S 2011 SEAGRAVE PUMPER(SN:78G45)
/SERVICE EACH 1.00 1.00 0.00 344.50 344.50
ANNUAL PUMP TESTING ON CUSTOMER'S 2003 ALF 75'QUINT(SN:0108975)
/SERVICE EACH 1.00 1.00 0.00 344.50 344.50
ANNUAL PUMP TESTING ON CUSTOMER'S 2002 KME PUMPER(SN:5016)
/SERVICE EACH 1.00 1.00 0.00 344.50 344.50
ANNUAL PUMP TESTING ON CUSTOMER'S 2011 SEAGRAVE PUMPER(SN:78G46)
/SERVICE EACH 1.00 1.00 0.00 344.50 344.50
ANNUAL PUMP TESTING ON CUSTOMER'S 2016 PIERCE PUMPER(SN:29584-02)
/SERVICE EACH 1.00 1.00 0.00 344.50 344.50
ANNUAL PUMP TESTING ON CUSTOMER'S 2016 PIERCE PUMPER(SN:29584-01)
/SERVICE EACH 1.00 1.00 0.00 344.50 344.50
ANNUAL PUMP TESTING ON CUSTOMER'S 1996 KME PUMPER(SN:2930)
/SERVICE EACH 1.00 1.00 0.00 344.50 344.50
ANNUAL PUMP TESTING ON CUSTOMER'S(SN:18125)
Net Invoice: 3,100.50
Less Discount: 0.00
Freight: 0.00
Sales Tax: 0.00
Invoice Total: 3,100.50
(� HOOSIER FIRE EQUIPMENT, INC. ❑ HOOSIER FIRE EQUIPMENT, INC.
QTY. PART NO. AND/OR DESCRIPTION PRICE 4009 Montdale Park Drive 3863 North Commercial Parkway
Valparaiso, IN 46383 Greenfield, IN 46140
Phone: 219-462-1707 Phone: 317-891-8375
Toll Free: 800-552-2691 Toll Free: 888-436-6075
REPAIR ORDER
NAME: Carmel Fire Department RECEIVED: 10/9/2018 DATE: 10/9/2018
CUSTOMER
ADDRESS: 2 Civic Square PROMISED: ORDER# 058675
CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB
PHONE: Scott Osborne cell 317-371-3140
MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR#
KME pumper 2003 5340 1 Engine 340 96,990.0 9189
LABOR 'LABOR
OURS REPAIR ORDER INSTRUCTIONS ' CHARGE
Perform annual pump testing $ 325.00
Set up fee $ 19.50
ADDITIONAL PARTS SEE LIST ON BACK
PARTS TOTAL y $ -
SUBLET WORK PRICE
I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees
permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing
and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto.
X TOTAL LABOR: $ 344.50
TOTAL PARTS: $ -
MILES TRAVEL RATE PRICE SUBLET WORK: $
NOT RESPONSIBLE FOR -. a
LOSS OR DAMAGE TO TRAVEL EXP. $ -
CARS OR ARTICLES
LEFT IN CARS IN CASE
T '
OF FIRE,THEFT OR ANY
OTHER CAUSE BEYOND -
SUBLET WORK TOTAL $ - OUR CONTROL. TOTAL TRAVEL EXPENSES: $ - TOTAL IIIIIIIIIIIIII10I $ 344.50
HOOSIER FIRE EQUIPMENT, INC.
MAIN OFFICE MID-STATE OFFICE
4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY
VALPARAISO, IN 46383 GREENFIELD, IN 46140
800-552-2691 888-436-6075
PUMP TEST REPORT
Customer: Carmel Fire Department Date: 10/9/2018
Address: 2 Civic Square Unit No#: Engine 340
City&St: Carmel, IN 46032 Engine: Gas: ❑ Diesel: X❑
Place of Test: Carmel Maintenance Facility Temperature: 75
Serial# 5340 Apparatus Year&Make: 2003 KME pumper
Miles: 96,990.0 Engine Hrs: 10,161.0
Pump Model: QMAX150-23L Serial No: 84575 Pump Hours: 982.0
Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: unknown
Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 7.23 Sec.
Vacuum Test: 22.5 In.with 0.5 Inches drop in 5 minutes Test Auxiliary Cooler: yes
Auto Pressure Control Type: governor Test-Max Increase: 10 P.S.I.
Test Plate Readings: 1504 GPM at 150 PSI at 1381 RPM
1051 GPM at 200 PSI at 1480 RPM
750 GPM at 250 PSI at 1665 RPM
Recommended Governed Engine Speed: 2400 RPM
Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min.
No.2-1/2" Lines: 3 Pump Control Position: 1,2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
10:00 1404 150 flowmeter 1510
10:05 1410 150 flowmeter 1510
10:10 1421 150 flowmeter 1500
10:15 1413 150 flowmeter 1500
Overload Test:
10:20 1 1 1471 165 flowmeter 1560
Oil Pressure: 44 PSI Water Temp: 150 F. Vacuum: 10 In. Volts 12.8
70% Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min.
No. 2-1/2"Lines: 2 Pump Control Position: 2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
10:25 1 1524 200 flowmeter 1050
10:30 1525 200 flowmeter 1050
10:35 1521 200 flowmeter 1050
Oil Pressure: 36 PSI Water Temp: 184 F. Vacuum: 6 In. Volts 12.7
50% Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min.
No. 2-1/2" Lines: 2 Pump Control Position: 2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
10:40 1669 250 flowmeter 750
10:45 1661 250 flowmeter 750
10:50 1663 250 flowmeter 750
Oil Pressure: 37 PSI Water Temp: 186 F. Vacuum: 3 In. Volts 12.7
Barometric Pressure 30.02 Test Water Temperature 84
CERTIFIED B) Christian Real TESTING ENGINEER
[-] HOOSIER FIRE EQUIPMENT, INC. [J HOOSIER FIRE EQUIPMENT, INC.
QTY. PART NO-.AND/OR DESCRIPTION , PRICE 4009 Montdale Park Drive 3863 North Commercial Parkway
Valparaiso, IN 46383 Greenfield, IN 46140
Phone: 219-462-1707 Phone: 317-891-8375
Toll Free: 800-552-2691 Toll Free: 888-436-6075
REPAIR ORDER
NAME: Carmel Fire Department RECEIVED: 10/8/2018 DATE: 10/8/2018
ADDRESS: 2 CIVIC Square PROMISED: ORDER#R ST2029
CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB
PHONE: Scott Osborne cell 317-371-3140
MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR#
Seagrave pumper 2011 78G45 I Engine 341 64,489.0 9189
LABOR. LABOR
REPAIR ORDER INSTRUCTIONS.
HOURS' CHARGE .
Perform annual pump testing $ 325.00
Set up fee $ 19.50
ADDITIONAL PARTS SEE LIST ON BACK
PARTS TOTAL
SUBLET WORK PRICE
I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees
permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing
and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto.
X TOTAL LABOR: $ 344.50
TOTAL PARTS: $ -
MILES TRAVEL RATE PRICE SUBLET WORK: $
NOT RESPONSIBLE FOR a
LOSS OR DAMAGE TO - TRAVEL EXP. $ -
CARS OR ARTICLES
LEFT IN CARS IN CASE TAX:
OF FIRE,THEFT OR ANY
-- OTHER CAUSE BEYOND . _
SUBLET WORK TOTAL $ - OUR CONTROL. TOTAL TRAVEL EXPENSES: $ - TOTAL $ 344.50
HOOSIER FIRE EQUIPMENT, INC.
MAIN OFFICE MID-STATE OFFICE
4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY
VALPARAISO, IN 46383 GREENFIELD, IN 46140
800-552-2691 888-436-6075
PUMP TEST REPORT
Customer: Carmel Fire Department Date: 10/8/2018
Address: 2 Civic Square Unit No#: Engine 341
City&St: Carmel, IN 46032 Engine: Gas: El Diesel: 0
Place of Test: Carmel Maintenance Facility Temperature: 83
Serial# 78G45 Apparatus Year&Make: 2011 Seagrave pumper
Miles: 64,489.0 Engine Hrs: 6,206.0
Pump Model: QMAX150-23L Serial No: A6794 Pump Hours: unknown
Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: unknown
Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 7.93 Sec.
Vacuum Test: 22.5 In.with 0.5 Inches drop in 5 minutes Test Auxiliary Cooler: yes
Auto Pressure Control Type: valve Test-Max Increase: 10 P.S.I.
Test Plate Readings: 1510 GPM at 150 PSI at 1354 RPM
1051 GPM at 200 PSI at 1496 RPM
750 GPM at 250 PSI at 1636 RPM
Recommended Governed Engine Speed: 2200 RPM
Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min.
No.2-1/2" Lines: 3 Pump Control Position: 1,2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
11:45 1373 150 flowmeter 1500
11:50 1373 150 flowmeter 1510
11:55 1374 150 flowmeter., 1510
12:00 1370 150 flowmeter 1500
Overload Test:
12:05 1 1 1416 165 1 flowmeter 1540
Oil Pressure: 48 PSI Water Temp: 188 F. Vacuum: 10 In. Volts 14.4
70%Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min.
No. 2-1/2" Lines: 2 Pump Control Position: 1,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
12:10 1 1491 200 flowmeter 1060
12:15 1490 200 flowmeter 1060
12:20 1493 200 flowmeter 1050
Oil Pressure: 48 PSI Water Temp: 186 F. Vacuum: 6.5 In. Volts 14.4
50%Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min.
No. 2-1/2" Lines: 2 Pump Control Position: 1,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
12:25 1623 250 flowmeter 750
12:30 1624 250 flowmeter 750
12:35 1623 250 flowmeter 760
Oil Pressure: 51 PSI Water Temp: 188 F. Vacuum: 45 In. Volts 14.4
Barometric Pressure 30.02 Test Water Temperature 86
CERTIFIED B) Christian Real TESTING ENGINEER
HOOSIER FIRE EQUIPMENT, INC. ❑ HOOSIER FIRE EQUIPMENT, INC.
QTY. PART NO. AND/OR DESCRIPTION PRICE 4009 Montdale Park Drive 3863 North Commercial Parkway
Valparaiso, IN 46383 Greenfield, IN 46140
Phone: 219-462-1707 Phone: 317-891-8375
Toll Free: 800-552-2691 Toll Free: 888-436-6075
REPAIR ORDER
NAME: Carmel Fire Department RECEIVED: 10/9/2018 DATE: 10/9/2018
CUSTOMER
ADDRESS: 2 CIVIC Square PROMISED: ORDER# K92637
CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB
PHONE: Scott Osborne cell 317-371-3140
MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE ARp
ALF 75'Quint 2003 0108975 Engine 342 107,386.0 9189
LABOR LABOR
REPAIRORDER INSTRUCTIONS .
HOURS CHARGE
Perform annual pump testing $ 325.00
Set up fee $ 19.50
ADDITIONAL PARTS SEE LIST ON BACK
PARTS TOTAL $ - -
SUBLET WORK PRICE
I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees
permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing
and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto.
X TOTAL LABOR: $ 344.50
TOTAL PARTS: $, -
NOT RESPONSIBLE FOR
MILES TRAVEL RATE PRICE SUBLET WORK: $ , -
_ ;_ ,
LOSS OR DAMAGE TO - 4` -
CARS OR ARTICLES TRAVEL EXP. $ _
LEFT IN CARS IN CASE
OF FIRE,THEFT OR ANY T '
OTHER CAUSE BEYOND _ -
SUBLETWORKTOTAL $ - OUR CONTROL. TOTALTRAVELEXPENSES: $ - - TOTAL $. 344.50
HOOSIER FIRE EQUIPMENT, INC.
MAIN OFFICE MID-STATE OFFICE
4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY
VALPARAISO, IN 46383 GREENFIELD, IN 46140
800-552-2691 888-436-6075
PUMP TEST REPORT
Customer: Carmel Fire Department Date: 10/9/2018
Address: 2 Civic Square Unit No#: Engine 342
City&St: Carmel, IN 46032 Engine: Gas: Diesel: X❑
Place of Test: Carmel Maintenance Facility Temperature: 80
Serial# 0108975 Apparatus Year&Make: 2003 ALF 75'Quint
Miles: 107,386.0 Engine Hrs: 8,730.0
Pump Model: QMAX150-23S Serial No: 82481 Pump Hours: 104.0
Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: 2.3
Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 5.2 Sec.
Vacuum Test: 22.5 In.with 1.5 Inches drop in 5 minutes Test Auxiliary Cooler: yes
Auto Pressure Control Type: governor Test-Max Increase: 10 P.S.I.
Test Plate Readings: 1504 GPM at 150 PSI at 1352 RPM
1051 GPM at 200 PSI at 1482 RPM
750 GPM at 250 PSI at 1629 RPM
Recommended Governed Engine Speed: 2225 RPM
Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min.
No.2-1/2" Lines: 3 Pump Control Position: 1,2,4
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
11:30 1396 150 flowmeter 1510
11:35 1397 150 flowmeter 1500
11:40 1383 150 flowmeter 1500
11:45 1382 150 flowmeter 1500
Overload Test:
11:50 1 1 1456 165 flowmeter 1600
Oil Pressure: 36 PSI Water Temp: 185 F. Vacuum: 11 In. Volts 14
70% Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min.
No.2-1/2" Lines: 2 Pump Control Position: 2,4
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
11:55 1 1504 200 flowmeter 1060
12:00 1512 200 flowmeter 1050
12:05 1507 200 flowmeter 1050
Oil Pressure: 36 PSI Water Temp: 194 F. Vacuum: 7 In. Volts 13.9
50%Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min.
No. 2-1/2" Lines: 2 Pump Control Position: 2,4
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
12:10 1 1667 250 1 flowmeter 1 760
12:15 1661 250 flowmeter 1 750
12:20 1657 250 flowmeter 1 750
Oil Pressure: 37 PSI Water Temp: 193 F. Vacuum: 4 In. Volts 13.9
Barometric Pressure 30.03 Test Water Temperature 84
CERTIFIED Bti Christian Real TESTING ENGINEER
[j] HOOSIER FIRE EQUIPMENT, INC. HOOSIER FIRE EQUIPMENT, INC.
'OTY.- PART NO:•AND/OR'DESCRIPTION PRICE. _ 4009 Montdale Park Drive 3863 North Commercial Parkway
Valparaiso, IN 46383 Greenfield, IN 46140
Phone: 219-462-1707 Phone: 317-891-8375
Toll Free: 800-552-2691 Toll Free: 888-436-6075
REPAIR ORDER
NAME: Carmel Fire Department RECEIVED: 10/8/2018 DATE: 10/8/2018
CUSTOMER
ADDRESS: 2 CIVIC Square PROMISED: ORDER# N058489
CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB
PHONE: Scott Osborne cell 317-371-3140
MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR#
KME pumper 2002 5016 Engine 343 103,265.0 9189
LABOR 1 `LABOR. v,
REPAIR-ORDER'INSTRUCTIONS
HOURS. T rCHARGE
Perform annual pump testing $ 325.00
Set up fee $ 19.50
ADDITIONAL PARTS SEE LIST ON BACK
4 PARTS 7OTAL $,
SUBLET WORK PRICE
hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees
permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing
and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto.
X TOTAL LABOR: $ •344.50
?OTAL PARTS: $. -
MILES TRAVEL RATE PRICE SUBLET WORK: $_ -
NOT RESPONSIBLE FOR _
LOSS OR DAMAGE TO TRAVEL'EXP $<
CARS OR ARTICLES _ -
LEFT IN CARS IN CASE '.TAX
OF FIRE,THEFT OR ANY
OTHER CAUSE BEYOND
SUBLET WORK TOTAL $ - ouRcoNTROL. TOTAL TRAVEL EXPENSES:, $ TOTAL $ 344.50
HOOSIER FIRE EQUIPMENT, INC.
MAIN OFFICE MID-STATE OFFICE
4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY
VALPARAISO, IN 46383 GREENFIELD, IN 46140
800-552-2691 888-436-6075
PUMP TEST REPORT
Customer: Carmel Fire Department Date: 10/8/2018
Address: 2 Civic Square Unit No#: Engine 343
City&St: Carmel, IN 46032 Engine: Gas: 1:1 Diesel: XD
Place of Test: Carmel Maintenance Facility Temperature: 71
Serial# 5016 Apparatus Year&Make: 2002 KME pumper
Miles: 103,265.0 Engine Hrs: 10,477.0
Pump Model: QMAX150-23L Serial No: 82415 Pump Hours: 829.6
Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: unknown
Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 15.6 Sec.
Vacuum Test: 22.5 In.with 9 Inches drop in 5 minutes Test Auxiliary Cooler: pass
Auto Pressure Control Type: governor Test-Max Increase: 10 P.S.I.
Test Plate Readings: 1504 GPM at 150 PSI at 1325 RPM
1051 GPM at 200 PSI at 1498 RPM
750 GPM at 250 PSI at 1662 RPM
Recommended Governed Engine Speed: 2400 RPM
Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min.
No. 2-1/2" Lines: 3 Pump Control Position: 1,2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
9:30 1410 151 flowmeter 1500
9:35 1394 150 flowmeter 1500
9:40 1395 150 flowmeter 1510
9:45 1390 150 flowmeter 1500
Overload Test:
9:50 1 1 1466 165 1 flowmeter 1590
Oil Pressure: 36 PSI Water Temp: 191 F. Vacuum: 11 In. Volts 13.7
70% Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min.
No.2-1/2" Lines: 2 Pump Control Position: 2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
9:55 1506 200 flowmeter 1060
10:00 1518 200 flowmeter 1060
10:05 1520 200 flowmeter 1050
Oil Pressure: 37 PSI Water Temp: 194 F. Vacuum: 5 In. Volts 13.8
50% Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min.
No. 2-1/2" Lines: 2 Pump Control Position: 2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
10:10 1656 250 flowmeter 750
10:15 1654 250 flowmeter 750
10:20 1658 250 flowmeter 750
Oil Pressure: 35 PSI Water Temp: 199 F. Vacuum: 4 In. Volts 13.7
Barometric Pressure 30.01 Test Water Temperature 70
CERTIFIED B) Christian Real TESTING ENGINEER
[__J HOOSIER FIRE EQUIPMENT, INC. HOOSIER FIRE EQUIPMENT, INC.
QTY. PART NO.-AND/OR DESCRIPTION PRICE 4009 Montdale Park Drive 3863 North Commercial Parkway
Valparaiso, IN 46383 Greenfield, IN 46140
Phone: 219-462-1707 Phone: 317-891-8375
Toll Free: 800-552-2691 Toll Free: 888-436-6075
REPAIR ORDER
NAME: Carmel Fire Department RECEIVED: 10/8/2018 DATE: 10/8/2018
CUSTOMER
ADDRESS: 2 CIVIC Square PROMISED: ORDER# ST2030
CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB
PHONE: Scott Osborne cell 317-371-3140
MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR#
Seagrave pumper 2011 78G46 Engine 344 56,899.0 9189
LABOR REPAIR ORDER INSTRUCTIONS' LABOR
HOURS. CHARGE
Perform annual pump testing $ 325.00
Set up fee $ 19.50
ADDITIONAL PARTS SEE LIST ON BACK am*
PARTS TOTAL y $ -
SUBLET WORK PRICE
I hereby authorise the above repair work to be done w/the necessary material,and hereby grant you and/or your employees
permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing
and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto.
X TOTAL LABOR: $ 344.50
TOTAL PARTS: $ -
MILES TRAVEL RATE PRICE SUBLET WORK: $ -
NOT RESPONSIBLE FOR a
LOSS OR DAMAGE TO TRAVEL EXP. $ -
CARS OR ARTICLES _
LEFT IN CARS IN CASE
OF FIRE,THEFT OR ANY TAX'
_ OTHER CAUSE BEYOND - _
SUBLET WORK TOTAL $- - 0UR CONTROL. TOTAL TRAVEL EXPENSES: $ - TOTAL -4 $ 344.50
HOOSIER FIRE EQUIPMENT, INC.
MAIN OFFICE MID-STATE OFFICE
4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY
VALPARAISO, IN 46383 GREENFIELD, IN 46140
��� 800-552-2691 888-436-6075
PUMP TEST REPORT
Customer: Carmel Fire Department Date: 10/8/2018
Address: 2 Civic Square Unit No#: Engine 344
City&St: Carmel, IN 46032 Engine: Gas: Diesel: 0
Place of Test: Carmel Maintenance Facility Temperature: 83
Serial# 78G46 Apparatus Year&Make: 2011 Seagrave pumper
Miles: 56,899.0 Engine Hrs: 4,586.0
Pump Model: QMAX150 Serial No: A6793 Pump Hours: unknown
Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: unknown
Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 13.1 Sec.
Vacuum Test: 22.5 In.with 4 Inches drop in 5 minutes Test Auxiliary Cooler: yes
Auto Pressure Control Type: valve Test-Max Increase: 10 P.S.I.
Test Plate Readings: 1510 GPM at 150 PSI at 1376 RPM
1051 GPM at 200 PSI at 1503 RPM
750 GPM at 250 PSI at 1644 RPM
Recommended Governed Engine Speed: 2200 RPM
Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min.
No.2-1/2" Lines: 3 Pump Control Position: 1,2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
12:45 1367 150 flowmeter 1510
12:50 1366 150 flowmeter 1510
12:55 1364 150 flowmeter 1500
13:00 1368 150 flowmeter 1500
Overload Test:
13:05 1 1 1433 1 165 flowmeter 1580
Oil Pressure: 45 PSI Water Temp: 190 F. Vacuum: 7 In. Volts 14.3
70% Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min.
No.2-1/2"Lines: 2 Pump Control Position: 2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
13:10 1490 200 flowmeter 1060
13:15 1486 200 flowmeter 1060
13:20 1489 200 flowmeter 1060
Oil Pressure: 47 PSI Water Temp: 192 F. Vacuum: 6.5 In. Volts 14.3
50%Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min.
No.2-1/2"Lines: 2 Pump Control Position: 2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
13:25 1636 250 flowmeter 750
13:30 1635 250 flowmeter 760
13:35 1630 250 flowmeter 750
Oil Pressure: 49 PSI Water Temp: 192 F. Vacuum: 45 In. Volts 14.3
Barometric Pressure 30.02 Test Water Temperature 82
CERTIFIED Bl Christian Real TESTING ENGINEER
El HOOSIER FIRE EQUIPMENT, INC. �_.) HOOSIER FIRE EQUIPMENT, INC.
QTY..; PART NO. AND/OR'DESCRIPTI:ON _ PRICE 4009 Montdale Park Drive 3863 North Commercial Parkway
Valparaiso, IN 46383 Greenfield, IN 46140
Phone: 219-462-1707 Phone: 317-891-8375
Toll Free: 800-552-2691 Toll Free: 888-436-6075
REPAIR ORDER
NAME: Carmel Fire Department RECEIVED: 10/8/2018 DATE: 10/8/2018
ADDRESS: 2 CIVIC Square PROMISED: ORDEOR#R 01675
CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB
PHONE: Scott Osborne cell 317-371-3140
MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR#
Pierce pumper 2016 29584-02 Engine 345 24,934.0 9189
LABOR' REPAIR ORDER-INSTRUCTIONS LABOR.
HOURS _ CHARGE
Perform annual pump testing $ 325.00
Set up fee $ 19.50
ADDITIONAL PARTS SEE LIST ON BACK
PARTS TOTAL $.. -
SUBLET WORK PRICE
I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees
permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing
and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto.
X TOTAL LABOR: $, 344.50
TOTAL PARTS: $ -
MILES TRAVEL RATE PRICE SUBLET WORK: $
NOT RESPONSIBLE FOR
LOSS OR DAMAGE TO _ ,TRAVEL EXP. $ -
CARS OR ARTICLES "'
jLEFTIN CARS IN CASE 'T' ;
FIRE,THEFT OR ANY., YON -.HER CAUSE BE D � _SUBLET WORK TOTAL 4 R CONTROL. 'TOT"L TRAVEL EXPENSES: $ - TOTAL =4 $ 344.50
HOOSIER FIRE EQUIPMENT, INC.
MAIN OFFICE MID-STATE OFFICE
4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY
VALPARAISO, IN 46383 GREENFIELD, IN 46140
800-552-2691 888-436-6075
PUMP TEST REPORT
Customer: Carmel Fire Department Date: 10/8/2018
Address: 2 Civic Square Unit No#: Engine 345
City&St: Carmel, IN 46032 Engine: Gas: Diesel: X❑
Place of Test: Carmel Maintenance Facility Temperature: 87
Serial# 29584-02 Apparatus Year&Make: 2016 Pierce pumper
Miles: 24,934.0 Engine Hrs: 2,072.0
Pump Model: QMAX150-23L Serial No: H10562 Pump Hours: 165.0
Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: unknown
Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 6.42 Sec.
Vacuum Test: 22.5 In.with 1.5 Inches drop in 5 minutes Test Auxiliary Cooler: pass
Auto Pressure Control Type: valve Test-Max Increase: 10 P.S.I.
Test Plate Readings: 1509 GPM at 150 PSI at 1410 RPM
1053 GPM at 200 PSI at 1533 RPM
750 GPM at 250 PSI at 1657 RPM
Recommended Governed Engine Speed: 2400 RPM
Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min.
No. 2-1/2"Lines: 3 Pump Control Position: 1,2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
14:10 1410 150 flowmeter 1500
14:15 1410 150 flowmeter 1500
14:20 1410 150 flowmeter 1510
14:25 1420 150 flowmeter 1500
Overload Test:
14:30 F 1490 165 flowmeter 1570
Oil Pressure: 43 PSI Water Temp: 194 F. Vacuum: 10.5 In. Volts 13.8
70% Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min.
No. 2-1/2"Lines: 2 Pump Control Position: 1,2
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
14:35 1 1520 200 flowmeter 1 1050
14:40 1510 200 flowmeter 1050
14:45 1510 200 flowmeter 1 1060
Oil Pressure: 42 PSI Water Temp: 194 F. Vacuum: 7 In. Volts 13.8
50% Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min.
No. 2-1/2"Lines: 2 Pump Control Position: 1,2
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
14:50 1 1650 250 flowmeter 760
14:55 1630 250 flowmeter 750
15:00 1640 250 flowmeter 760
Oil Pressure: 46 PSI Water Temp: 189 F. Vacuum: 5.5 In. Volts 13.8
Barometric Pressure 30.04 Test Water Temperature 80
CERTIFIED B) Christian Real TESTING ENGINEER
HOOSIER FIRE EQUIPMENT, INC. ❑ HOOSIER FIRE EQUIPMENT, INC.
QTY. PART NO. AND/OR DESCRIPTION PRICE 4009 Montdale Park Drive 3863 North Commercial Parkway
Valparaiso, IN 46383 Greenfield, IN 46140
Phone: 219-462-1707 Phone: 317-891-8375
Toll Free: 800-552-2691 Toll Free: 888-436-6075
REPAIR ORDER
NAME: Carmel Fire Department RECEIVED: 10/9/2018 DATE: 10/9/2018
ADDRESS: 2 CIVICS Square PROMISED: CUSTOMER 01674
q ORDER#
CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB
PHONE: Scott Osborne cell 317-371-3140
MAKE: MODEL: YR. SERIAL N0. UNIT MILEAGE ARM
Pierce pumper 2016 29584-01 Engine 346 21,541.0 9189
LABOR - LABOR
OURS REPAIR ORDER INSTRUCTIONS CHARGE
Perform annual pump testing $ 325.00
Set up fee $ 19.50
ADDITIONAL PARTS SEE LIST ON BACK
PARTS TOTAL ly $ -
SUBLET WORK PRICE
I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees
permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing
and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto.
X TOTAL LABOR: $ 344.50
TOTAL PARTS: $ -
MILES TRAVEL RATE PRICE SUBLET WORK: $ -
NOT RESPONSIBLE FOR
LOSS OR DAMAGE TO TRAVEL EXP. $ -
CARS OR ARTICLES
LEFT INCA SIN CASE
OF FIRE,THEFT OR ANY TAX'
OTHER CAUSE BEYOND
SUBLET WORK TOTAL $ - IOUR CONTROL. I TOTAL TRAVEL EXPENSES: $ - TOTAL $ 344.50
HOOSIER FIRE EQUIPMENT, INC.
MAIN OFFICE MID-STATE OFFICE
4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY
VALPARAISO, IN 46383 GREENFIELD, IN 46140
800-552-2691 888-436-6075
PUMP TEST REPORT
Customer: Carmel Fire Department Date: 10/9/2018
Address: 2 Civic Square Unit No#: Engine 346
City&St: Carmel, IN 46032 Engine: Gas: El Diesel: X❑
Place of Test: Carmel Maintenance Facility Temperature: 69
Serial# 29584-01 Apparatus Year&Make: 2016 Pierce pumper
Miles: 21,541.0 Engine Hrs: 11718.0
Pump Model: QMAX150-23L Serial No: H10562 Pump Hours: 128.0
Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: unknown
Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 16.2 Sec.
Vacuum Test: 22.5 In.with 1 Inches drop in 5 minutes Test Auxiliary Cooler: pass
Auto Pressure Control Type: valve Test-Max Increase: 10 P.S.I.
Test Plate Readings: 1509 GPM at 150 PSI at 1418 RPM
1053 GPM at 200 PSI at 1540 RPM
750 GPM at 250 PSI at 1680 RPM
Recommended Governed Engine Speed: 2400 RPM
Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min.
No. 2-1/2"Lines: 3 Pump Control Position: 1,2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
9:15 1420 150 flowmeter 1510
9:20 1410 150 flowmeter 1500
9:25 1420 150 flowmeter 1510
9:30 1410 150 flowmeter 1500
Overload Test:
935 1490 165 flowmeter 1590
Oil Pressure: 49 PSI Water Temp: 190 F. Vacuum: 10 In. Volts 12.7
70%Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min.
No.2-1/2"Lines: 2 Pump Control Position: 1,2
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
9:40 1520 1 200 flowmeter 1050
9:45 1530 200 flowmeter 1 1060
9:50 1530 200 flowmeter 1 1060
Oil Pressure: 47 PSI Water Temp: 187 F. Vacuum: 7 In. Volts 12.8
50%Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min.
No. 2-1/2" Lines: 2 Pump Control Position: 1,2
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
9:55 1660 250 1 flowmeter 750
10:00 1660 250 1 flowmeter 750
10:05 1650 250 1 flowmeter 750
Oil Pressure: 47 PSI Water Temp: 190 F. Vacuum: 3 In. Volts 12.9
Barometric Pressure 30.01 Test Water Temperature 76
CERTIFIED Bl Christian Real TESTING ENGINEER
( 1 HOOSIER FIRE EQUIPMENT, INC. Ej HOOSIER FIRE EQUIPMENT, INC.
QTY: PART NO.AND/OR DESCRIPTION PRICE 4009 Montdale Park Drive 3863 North Commercial Parkway
Valparaiso, IN 46383 Greenfield, IN 46140
Phone: 219-462-1707 Phone: 317-891-8375
Toll Free: 800-552-2691 Toll Free: 888-436-6075
REPAIR ORDER
NAME: Carmel Fire Department RECEIVED: 10/8/2018 DATE: 10/8/2018
CUSTOMER
ADDRESS: 2 CIVIC Square PROMISED: ORDER# 058491
CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB
PHONE: Scott Osborne cell 317-371-3140
MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR It
KME pumper 1996 2930 Engine 349 106,959.0 9186
LABOR : - REPAIR ORDER INSTRUCTIONS' .'LABOR
HOURS ;- CHARGE:
Perform annual pump testing $ 325.00
Set up fee $ 19.50
ADDITIONAL PARTS SEE LIST ON BACK
PARTS TOTAL $.' -
SUBLET WORK PRICE
I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees
permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing
and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto.
X TOTAL LABOR: $ 344.50
TOTAL PARTS: $ -
MILES TRAVEL RATE PRICE SUBLET WORK: $
NOT RESPONSIBLE FOR - - - _
LOSS OR DAMAGE TO 'TRAVEL
CARS OR ARTICLES
LEFT IN CARS IN CASE TAX:
OF FIRE,THEFT OR ANY _ - -
OTHER CAUSE BEYO" F77
-
SUBLET WORK TOTAL .$ OUR CONTROL. TOTAL TRAVEL EXPENSES: ' $ - TOTAL = '$ "344.50
HOOSIER FIRE EQUIPMENT, INC.
. , MAIN OFFICE MID-STATE OFFICE
4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY
VALPARAISO, IN 46383 GREENFIELD, IN 46140
800-552-2691 888-436-6075
PUMP TEST REPORT
Customer: Carmel Fire Department Date: 10/8/2018
Address: 2 Civic Square Unit No#: Engine 349
City&St: Carmel, IN 46032 Engine: Gas: Diesel:
Place of Test: Carmel Maintenance Facility Temperature: 72
Serial# 2930 Apparatus Year&Make: 1996 KME pumper
Miles: 106,959.0 Engine Hrs: 11,312.0
Pump Model: QSMG150-23L Serial No: 69971 Pump Hours: 1,261.0
Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: unknown
Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 10.7 Sec.
Vacuum Test: 22.5 In.with 4 Inches drop in 5 minutes Test Auxiliary Cooler: yes
Auto Pressure Control Type: valve Test-Max Increase: 10 P.S.I.
Test Plate Readings: 1504 GPM at 150 PSI at 1417 RPM
1051 GPM at 200 PSI at 1533 RPM
750 GPM at 250 PSI at 1678 RPM
Recommended Governed Engine Speed: 2400 RPM
Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min.
No.2-1/2" Lines: 3 Pump Control Position: 1,2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
10:10 1430 150 flowmeter 1510
10:15 1430 150 flowmeter 1510
10:20 1430 150 flowmeter 1500
10:25 1430 150 flowmeter 1500
Overload Test:
10:30 1 1 1500 165 1 flowmeter 1560
Oil Pressure: 50 PSI Water Temp: 180 F. Vacuum: 10.5 In. Volts 13.8
70% Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min.
No.2-1/2"Lines: 2 Pump Control Position: 2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
10:35 1 1530 200 flowmeter 1060
10:40 1530 200 flowmeter 1060
10:45 1530 200 flowmeter 1050
Oil Pressure: 40 PSI Water Temp: 205 F. Vacuum: 7 In. Volts 13.8
50% Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min.
No. 2-1/2"Lines: 2 Pump Control Position: 2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
10:50 1670 250 flowmeter 750
10:55 1670 250 flowmeter 750
11:00 1670 250 flowmeterF 750
Oil Pressure: 36 PSI Water Temp: 210 F. Vacuum: 5 In. Volts 13.8
Barometric Pressure 30.01 Test Water Temperature 76
CERTIFIED Bl Christian Real TESTING ENGINEER
E HOOSIER FIRE EQUIPMENT, INC. ❑ HOOSIER FIRE EQUIPMENT, INC.
QTY. PART NO: AND/OR DESCRIPTION" PRICE 4009 Montdale Park Drive 3863 North Commercial Parkway
Valparaiso, IN 46383 Greenfield, IN 46140
Phone: 219-462-1707 Phone: 317-891-8375
Toll Free: 800-552-2691 Toll Free: 888-436-6075
REPAIR ORDER
NAME: Carmel Fire Department RECEIVED: 10/9/2018 DATE: 10/9/2018
ADDRESS: 2 CIVICS uare CUSTOMER
PROMISED: ORDER#
088012
Q
CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB
PHONE: Scott Osborne cell 317-371-3140
MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR#
Grumman 102'tower 1989 18125 ILadder3401 56,526.0 9189
LABOR REPAIR ORDER INSTRUCTIONS LABOR
HOURS : CHARGE
Perform annual pump testing $ 325.00
Set up fee $ 19.50
ADDITIONAL PARTS SEE LIST ON BACK
PARTS TOTAL $ -
SUBLET WORK PRICE
I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees
permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing
and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto.
X TOTAL LABOR: $ 344.50
TOTAL PARTS: $ -
MILES TRAVEL RATE PRICE SUBLET WORK: $ -
NOT RESPONSIBLE FOR " a
LOSS OR DAMAGE TO TRAVEL EXP. $
CARS OR ARTICLES
LEFT IN CARS IN CASE _
OF FIRE,THEFT OR ANY TAX.
SUBLET WORK TOTAL $ _ OTHER CAUSE BEYOND
oUR CONTROL. TOTALTRAVELEXPENSES: $ TOTAL [Lii�d
HOOSIER FIRE EQUIPMENT, INC.
MAIN OFFICE MID-STATE OFFICE
4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY
VALPARAISO, IN 46383 GREENFIELD, IN 46140
800-552-2691 888-436-6075
PUMP TEST REPORT
Customer: Carmel Fire Department Date: 10/9/2018
Address: 2 Civic Square Unit No#: Ladder 340
City&St: Carmel, IN 46032 Engine: Gas: 1-1 Diesel: MR
Place of Test: Carmel Maintenance Facility Temperature: 80
Serial# 18125 Apparatus Year&Make: 1989 Grumman 102'tower
Miles: 56,526.0 Engine Hrs: 6,809.0
Pump Model: CMU YBX Serial No: 13977W Pump Hours: unknown
Rated Capacity: 1500 GPM Stages: 2 Pump Ratio: 2.48
Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 7.43 Sec.
Vacuum Test: 22.5 In.with 0.5 Inches drop in 5 minutes Test Auxiliary Cooler: yes
Auto Pressure Control Type: valve Test-Max Increase: 10 P.S.I.
Test Plate Readings: 1500 GPM at 150 PSI at 1468 RPM VOLUME MODE
1050 GPM at 200 PSI at 1563 RPM VOLUME MODE
750 GPM at 250 PSI at 1360 RPM PRESSURE MODE
Recommended Governed Engine Speed: unknown RPM
Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min.
No.2-1/2" Lines: 3 Pump Control Position: 1,2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
12:30 1480 150 flowmeter 1500 VOLUME MODE
12:35 1480 150 flowmeter 1500 VOLUME MODE
12:40 1480 150 flowmeter 1510 VOLUME MODE
12:45 1480 150 flowmeter 1500 VOLUME MODE
Overload Test:
12:50 1 1 1510 1 165 flowmeter 1590 VOLUME MODE
Oil Pressure: 40 PSI Water Temp: 190 F. Vacuum: 11.5 In. Volts 12.8
70%Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min.
No.2-1/2" Lines: 2 Pump Control Position: 2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
flowmeter VOLUME MODE
0:05 flowmeter VOLUME MODE
0:10 flowmeter VOLUME MODE
Oil Pressure: PSI Water Temp: F. Vacuum: In. Volts
50% Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min.
No.2-1/2" Lines: 2 Pump Control Position: 2,3
Time Counter Eng. RPM Pump Press. Pitot GPM Notes
flowmeter T PRESSURE MODE
0:05 1 flowmeter PRESSURE MODE
0:10 1 flowmeter PRESSURE MODE
Oil Pressure: PSI Water Temp: F. Vacuum: In. Volts
Barometric Pressure Test Water Temperature
CERTIFIED B) Christian Real TESTING ENGINEER
Customer: Carmel Fire Department Date: 10/9/2018
Address: 2 Civic Square Unit No#: Ladder 340
City& St: Carmel, IN 46032
Serial# 18125 Apparatus Year& Make: 1989 Grumman 102' tower
Pump Model: CMU YBX Serial No: 13977W
Miles: 56,526.0 Engine Hrs: 6,809.0
NOTES TO PUMP TEST:
TEST'STOPPED AFTER 1'50-PS('CAPA`CITY'T,EST.—Engine overheating. rf