Loading...
HomeMy WebLinkAboutM002.0Truss Connector Total List Manuf Product Qty HUS26 24 JL24 7 USP JL24IF-TZ 1 JUS24 8 USP One RT4 67 Two RT4 1 ATTIC ACCESS CGE01 CT01 BGE01 BGR01 FGE01 DGR01 EGE01 FGR01 AGE03 AGE01 DGR02 AGE02 AT06 AT09 AGE04 V11 V8 V6 V4 V2 V9 V11 V8 V6 V11 V8 V6 V10 V7 V5 V3 V1 V JL24IF-TZ Two RT4 BT01(2) ET01(4) AT01(2) AT02(3) AT05(3) AT08(2) DT01(9) AT04(4) AT03(4) AT07(5) HUS26 JL24 HUS26 HUS26 JUS24 JL24 HUS26HUS26 JUS24 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 1-06-00 1-04-08 1-06-00 2-00-00 2-00-00 3-00 1-02-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 20-07-00 9-09-08 4-10-00 8-10-15 71-07-01 1-04-00 1-06-00 2-00-00 2-00-00 1-09-00 4-10-00 6-02-00 10-08-00 8-08-08 1-04-00 30-04-08 86-08-00 8-11-08 15-01-08 5-08-00 19-02-00 14-07-08 34-03-08 IMPORTANT THIS DRAWING IS FOR FIELD PLACEMENT OF INDIVIDUAL COMPONENTS ONLY, AND DOES NOT CONSTITUTE AN ENGINEERED DOCUMENT. NOTE PROPER BEARING AND BEARING DESIGN INCLUDING ANCHORAGE, IS THE RESPONSIBILITY OF THE BUILDING DESIGNER, ARCHITECT AND / OR BUILDING ENGINEER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR REACTIONS, MINIMUM REQUIRED BEARING SIZE, UPLIFT, AND ADDITIONAL LOADS. 84 COMPONENTS DOES NOT ASSUME RESPONSIBILITY IN THESE AREAS OF CONCERN. BRACING ERECTION, TEMPORARY, AND PERMANENT BRACING IS THE RESPONSIBILITY OF THE CONTRACTOR AND / OR BUILDING DESIGNER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR ADDITIONAL BRACING REQUIREMENTS. REFER TO BCSI-B1 SUMMARY SHEET. THE STRUCTURAL BUILDING COMPONENTS ASSOCIATION COMMENTARY, AND RECOMMENDATIONS FOR HANDLING, INSTALLING & BRACING METAL PLATE CONNECTED WOOD TRUSSES. www.sbcindustry.com INSTALLATION DO NOT CUT, DRILL, OR ALTER TRUSSES. ANY QUESTIONS CALL 84 COMPONENTS. PROPER INSTALLATION, AND HANDLING OF COMPONENTS IS THE RESPONSIBILITY OF THE ERECTING CONTRACTOR. 84 COMPONENTS MUST BE NOTIFIED OF ANY PROBLEMS, AND AFFORDED THE OPPORTUNITY TO REVIEW, AND MAKE NECESSARY CORRECTIONS, OR NO BACK CHARGES WILL BE ACCEPTED OR APPROVED. WARNING WARNINGS, AND INSTRUCTIONS FOR ERECTION OF COMPONENTS ARE INCLUDED IN THE DELIVERY PACKAGE. KEEP TH IS INFORMATION ON THE JOB SITE. THESE DOCUMENTS WILL ALSO BE NEEDED FOR JOB SITE INSPECTION. MISUSE AND IMPROPER INSTALLATION OF COMPONENTS MAY RESULT IN FAILURE, BODILY INJURY, LOSS OF PROPERTY, AND / OR LIFE. Roof Area: Overhang Length: Eave Length: Hip Length: Valley Length: Ridge Length: SHEET NUMBER: R1.1 Roof Truss Placement Plan SCALE: NTS Job#: 1802947RA PO#: Date: 11/20/2018 Drawn By: Designed By: Checked By: ROOF LOADS: TCLL: 20.0 lb/ft² TCDL: 10.0 lb/ft² BCLL: 0.0 lb/ft² BCDL:10.0 lb/ft² Building Code: IRC2015 Wind Speed: 115 mph On-Center Spacing: 24" U.N.O. 2833 SF 181 LF 246 LF 0 LF 144 LF 132.19 LF ROOF DATA THIS LAYOUT IS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENT ONLY. REFER TO THE BUILDING PLANS FOR ACTUAL BUILDING CONSTRUCTION. TG59 A/B Pyatt Builders 59, The Grove at Legacy Carmel, IN ROOF TRUSS PLACEMENT PLAN 1802947RA 1850 N Graham Road Franklin, Indiana 46131 Office:(317) 346-4274 Fax: (317) 346-0916 PLAN DATE: 11/14/18_SHEET-2 12/26/18 Adam Schriner