Loading...
HomeMy WebLinkAbout18120002 State ReleaseELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 1/2 CONSTRUCTION DESIGN RELEASE State Form 41191 (R9/5-98) Report Printed on: November 28, 2018 Project number Release date 403207 11/28/18 Construction type Occupancy classification Scope of release II-B, SPK A-3, REM Type of release Project name Street address City County ARCH ELEC MECH PLUM Standard Sol Hot Yoga Studio Inc 7245 E 146th St CARMEL HAMILTON To: Owner / Architect / Engineer Soe Lin & Associates Michael Greigg AR11800170 4340 East West HWY Ste 105 Bethesda MD 20814 Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: 14B 4G0412AE 4G0603AF 14B0601IIB 14B1008110 14B101163 14B11092 14M05041 14M05044 This project has been reviewed under the 2014 Indiana Building Code. The proposed building, addition, or remodel shall not put the existing building in noncompliance or into further noncompliance in accordance with 675 IAC 12-4-12. Detailed plans and specifications for the revised fire suppression system shall be filed with the required application and appropriate fees in accordance with 675 IAC 12-6- 3(a), 675 IAC 12-6- 7(g)(17), and 675 IAC 13-1-8. (N.F.P.A. 13) The minimum construction type permitted for this building is Type II-B. Building elements shall be protected as specified in Chapters 5, 6, and Table 601, IBC (675 IAC 13-2.6). Doors serving a Group H occupancy, or an occupant load of 50 or more in a Group A or E occupancy, shall not be provided with a latch or lock unless it is panic hardware or fire exit hardware in accordance with Section 1008.1.10, IBC (675 IAC 13-2.6). Exit illumination and exit signs shall be connected to a separate emergency power source in ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report Page 2/2 9E21008B 9E41036 AREL In other than dwelling units all 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in (1) through (5) shall have ground-fault circuit-interrupter protection for personnel: (1) Bathrooms (2) Kitchens (3) Rooftops (4) Outdoors and (5) within six (6) feet of the outside edge of sinks in accordance with Section 210.8(B), IEC (675 IAC 17-1.8). Luminaires shall be installed and supported in accordance with Section 410.36. IEC (675 IAC 17- 1.8). Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from required compliance with all applicable rules of the commission, even if noncompliant conditions appear in the plans and specifications that have been filed with the division. The owner is responsible for correcting any and all areas of noncompliance even if they are discovered subsequent to the issuing of this design release. Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above - stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will be final, and you must comply with its requirements. Code review official Address (name,title of local official,street,city,state and ZIP code EDWARD HENN JIM BLANCHARD ONE CIVIC SQUARE CARMEL, IN 46032 DEPT OF COMMUNITY SERVICE Fax & e-mail: 3175712499, jblanchard@carmel.in.gov ehenn@dhs.in.gov Director, Division of Fire and Building Safety accordance with Section 1011.6.3, IBC (675 IAC 13-2.6). Each toilet room and bathing room shall be handicapped accessible in accordance with Section 1109.2, IBC (675 IAC 13-2.6). (Clear turning radius, Door Swing, Grab Bars, Fixture Clearances, Fixture Mounting Heights, Shower/Bathtub seats) Dryer exhaust systems shall be independent of all other systems and shall convey the moisture and any products of combustion to the outside of the building, in accordance with Section 504.1, IMC (675 IAC 18-1.6). Clothes dryer exhaust ducts shall terminate on the outside of the building, and shall be equipped with a backdraft damper; ducts shall not be connected or installed with sheet metal screws or other fasteners that will obstruct exhaust flow; in accordance with Section 504.4, IMC (675 IAC 18-1.6). Indiana Department of Homeland Security DIVISION OF FIRE & BUILDING SAFETY PLAN REVIEW DIVISION 402 W. Washington St., Room E245 Indianapolis, IN 46204 Fax & e-mail: SUPPORT HOOSIER SAFETY Available At Your Local Licence Branch In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. 3019860500, mgreigg@soelin.com