DANSCO ENGINEERING, LLC
P.O. Box 3400
Apollo Beach, FL 33572
Telephone (813) 645-0166
Facsimile (813) 645-9698
The truss drawing(s) listed below have been prepared by Stark Truss, Inc. under my
direct supervision based on the parameters provided by the truss designers.
Job: 1803054-12T
90 truss design(s)
62831-W1
12/6/18
Samuel A. Greenberg, P.E.
Indiana Reg. #19700485
Note: Gable end frames with stud lengths exceeding 4’ require permanent bracing. On structural
gables, where studs may be made from two or more boards as they cross diagonals, the 4’ length
is the distance from the top chord to bottom chord.
The seal on these drawings indicate acceptance of professional engineering
responsibility solely for the truss components shown. The suitability and use of this
component for any particular building is the responsibility of the building designer, per
ANSI/TPI 1-2007 Chapter 2.
Warning !—Verify design parameters and read notes before use.
These designs are based only upon parameters shown, and are for individual building components to be installed and loaded vertically. Applicability of
design parameters and proper incorporation of component is responsibility of building designer – not truss designer or truss engineer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to ensure stability during construction is the responsibility of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication,
quality control, storage, delivery, erection and bracing, consult ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss
Construction and BCSI 1-03 Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses from Truss Plate
Institute, 583 D’Onofrio Drive, Madison, WI 53719
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
J01
TrussType
Jack-OpenGirder
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:222018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-L9o6fZHksof4UKD31TGXH0uSJ9FnA0F87snSpByDzgN
Scale=1:16.4
W1
T1
B1
1
2
5
6
3
4
3x4
3x4
2-9-5
2-9-5
-2-10-0
2-10-0
2-9-5
2-9-5
1-9-8
2-8-1
0-4-2
2-3-14
2-8-1
3.8012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
J02
TrussType
Jack-Closed
Qty
6
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:232018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-pLMUtvIMc6nx6UoGbAnmqERmsZcdvTVHLWW0LeyDzgM
Scale=1:16.6
W1
T1
W2
B1
1
2
3
5
4
6
7
8
3x4
2x4
2x4
2x4
4-0-0
4-0-0
-1-10-12
1-10-12
4-0-0
4-0-0
1-4-13
2-8-13
2-5-5
0-3-8
2-8-13
4.0012
LOADING (psf)
TCLL
TCDL
BCLL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
J03
TrussType
Jack-Closed
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:242018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-HXws4FJ_NPvokeNS8uI?MRzxNzynewlRaAGZt4yDzgL
Scale=1:16.6
W1
T1
W2
B1
1
2
4
3
5
3x4
1.5x4
2x4
2x4
4-0-0
4-0-0
4-0-0
4-0-0
1-4-13
2-8-13
2-5-5
0-3-8
2-8-13
4.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
J04
TrussType
DiagonalHipGirder
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:252018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-lkUEIbKc8j1fLoyeibqEvfW7VNIuNN?apq?7PWyDzgK
Scale=1:14.2
W1
T1
B1
1
2
5
6
3
4
1.5x4
1.5x4
3-4-15
3-4-15
-1-3-3
1-3-3
3-4-15
3-4-15
1-2-15
2-3-0
0-4-1
1-10-14
2-3-0
3.5412
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
J05
TrussType
Jack-Open
Qty
14
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:262018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-Dw2dVxLEv1AWzyXrGJLTRs3Ilneo6qFj2UlgyzyDzgJ
Scale=1:14.4
W1
T1
B1
1
2
5
6
3
4
2x4
2x4
2-6-0
2-6-0
-0-10-12
0-10-12
2-6-0
2-6-0
1-2-15
2-3-7
1-11-0
2-3-7
5.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
J06
TrussType
Jack-Open
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:272018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-h6b?jHLsgKINb551q0si_4bUpA?UrHUtG8UDUPyDzgI
Scale=1:13.0
W1
T1
B1
1
2
5
3
1.5x4 4
2x4
1-9-7
1-9-7
-0-10-12
0-10-12
1-9-7
1-9-7
1-2-15
1-11-14
1-7-7
1-11-14
5.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
J07
TrussType
DiagonalHipGirder
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:282018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-9J9NwdMUReQECFgDNkNxXH8dYaIKakk0VoEn0ryDzgH
Scale=1:17.6
W1
T1
B1
1
2
5
6
7
8
9
3
10 11 12 4
3x4
2x4
5-2-2
5-2-2
-1-3-3
1-3-3
5-2-2
5-2-2
1-2-15
2-9-4
2-5-2
2-9-4
3.5412
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
J07
TrussType
DiagonalHipGirder
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:282018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-9J9NwdMUReQECFgDNkNxXH8dYaIKakk0VoEn0ryDzgH
LOADCASE(S) Standard
Trapezoidal Loads(plf)
Vert: 2=-2(F=24,B=24)-to-3=-66(F=-7,B=-7), 5=0(F=10,B=10)-to-4=-26(F=-3,B=-3)
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
J08
TrussType
Jack-Open
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:292018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-dVjl7zN7CyY5qPFQxRuA3Uhqr_gKJB_AkSzKYHyDzgG
Scale=1:11.6
W1
T1
B1
1
2
5
3
1.5x4 4
1.5x4
1-1-7
1-1-7
-0-10-12
0-10-12
1-1-7
1-1-7
1-2-15
1-8-9
1-4-2
1-8-9
5.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
J09
TrussType
Jack-Open
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:302018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-6hH7LIOlzFgySZqcV9PPciD_jO?i2eEJy6ju5kyDzgF
Scale=1:14.5
W1
T1
B1
1
2
5
6
3
4
2x4
2x4
2-6-7
2-6-7
-0-10-12
0-10-12
2-6-7
2-6-7
1-2-15
2-3-10
5.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
J10
TrussType
Jack-Open
Qty
2
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:312018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-aurWYeONkZop3jPo3swe8vm9yoKfn5USBmSRdAyDzgE
Scale=1:17.0
W1
T1
B1
1
4
5
2
3
2x4
2x4
3-9-0
3-9-0
3-9-0
3-9-0
1-2-15
2-9-11
2-5-4
2-9-11
5.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
J11
TrussType
Jack-Open
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:322018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-24Pum_P?Vtwfht__cZSth7IKeBgjWYUcQQC_9cyDzgD
Scale=1:17.0
0-1-10
W1
T1
T2
B1
W2
1
2
6
5
3
4
2x4
3x4
4x4
1.5x4
2-5-14
2-5-14
3-9-0
1-3-2
2-5-14
2-5-14
3-9-0
1-3-2
2-1-12
2-9-11
2-5-4
2-9-11
2-1-12
5.0012
LOADING (psf)
TCLL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
J12
TrussType
DiagonalHipGirder
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:332018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-WGzGzKQdGA2WJ0ZBAHz6DKrVUb2vF?zlf4xYh3yDzgC
Scale=1:13.9
W1
T1
B1
1
2
5
6
3
4
1.5x4
1.5x4
3-2-13
3-2-13
-1-3-3
1-3-3
3-2-13
3-2-13
1-2-15
2-2-6
3.5412
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
J13
TrussType
Jack-Open
Qty
7
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:342018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-_SWeBgRF1UANwA8Nk_ULmYOgd?Nk_RDvtkh5EVyDzgB
Scale=1:14.2
W1
T1
B1
1
2
5
3
4
2x4
2x4
2-4-8
2-4-8
-0-10-12
0-10-12
2-4-8
2-4-8
1-2-15
2-2-13
1-10-6
2-2-13
5.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
PB01
TrussType
GABLE
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:352018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-Sf40O0StooIEYKjZIi?aJlwtpPkrju_26OQemxyDzgA
Scale=1:29.3
T1 T1
B1
ST1 ST1
1
2
3
4
5
6
7
9 8
10
11
12
13
3x4
2x4 2x4
1.5x4
1.5x4
1.5x4
1.5x4
8-9-0
8-9-0
4-4-8
4-4-8
8-9-0
4-4-8
0-5-3
4-4-8
0-1-10
0-5-3
0-1-10
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
PB01GE
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:362018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-wrePcMSWY5Q5AUHmrPWprzT2Yp3_SL1CL2ACINyDzg9
Scale=1:27.7
T1 T1
B1
ST2
ST1
ST2
ST1
1
2
3
4
5
6
7
9 8
13 12 11 10
14
15
3x4
2x4 2x4
8-9-0
8-9-0
4-4-8
4-4-8
8-9-0
4-4-8
0-5-3
4-4-8
0-1-10
0-5-3
0-1-10
12.0012
PlateOffsets(X,Y)-- [2:0-2-6,0-1-0], [5:0-2-0,Edge], [8:0-2-6,0-1-0]
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
PB02
TrussType
GABLE
Qty
14
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:372018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-P1CnpiT8JPYynesyP712OA0BICOIBnYLZivlqqyDzg8
Scale=1:33.1
W1
T1
T2
B1
ST2
ST1
1
2
3
4
5
8 7 6
9
10
11
1.5x4
1.5x4
4x4
3x4
1.5x4
1.5x4
1.5x4
10-9-12
10-9-12
2-11-0
2-11-0
10-9-12
7-10-12
3-2-3
5-3-2
0-1-10
0-4-7
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
PB02GE
TrussType
GABLE
Qty
2
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:382018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-tEm901Um4jgpPoR8zqYHwOYNLclJwFOUoMfJNGyDzg7
Scale=1:31.0
W1
T1
T2
B1
ST1 ST1
ST2
ST3
1
2
3
4
5
6
7
8
13 12 11 10 9
14
15
3x4
3x4
10-9-12
10-9-12
2-11-0
2-11-0
10-9-12
7-10-12
3-2-3
5-3-2
0-1-10
0-4-5
0-1-10
0-1-6
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
PB03
TrussType
Piggyback
Qty
5
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:392018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-LQKXENVOr0og1x0LXX4WTb5WV04Ofipe10OsviyDzg6
Scale=1:19.6
T1 T1
B1
ST1
1
2
3
4
5
6
7
8
9
10
11
12
4x4
2x4 1.5x4 2x4
8-9-7
8-9-7
4-4-12
4-4-12
8-9-7
4-4-11
0-4-7
2-11-2
0-1-10
0-4-7
0-1-10
8.0012
LOADING (psf)
TCLL
TCDL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
PB03GE
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:402018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-pcuvRjV0cKwXf5bX4Fbl0peiFQRhO95nGg8PR9yDzg5
Scale=1:19.6
T1 T1
B1
ST1 ST1
1
2
3
4
5
6
7
9 8
10
11
12
13
3x4
2x4 1.5x4 2x4
1.5x4
1.5x4
1.5x4
8-9-7
8-9-7
4-4-12
4-4-12
8-9-7
4-4-11
0-4-7
2-11-2
0-1-10
0-4-7
0-1-10
8.0012
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
PB04
TrussType
Piggyback
Qty
5
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:412018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-HpSIf3WeNe2OGFAjey6_Y0Ar?qmF7cNxUKtz_byDzg4
Scale=1:19.4
W1
T1
T2
B1
ST1
1
2
3
4
6 5
7
8
9
1.5x4
1.5x4
4x4
1.5x4 2x4
6-0-12
6-0-12
1-8-0
1-8-0
6-0-12
4-4-11
1-8-3
2-11-2
0-1-10
0-4-7
0-1-10
8.0012
LOADING (psf)
TCLL
TCDL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
PB05
TrussType
Piggyback
Qty
1
Ply
3
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:422018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-l??gsPXG8xBFuPlvCgdD5Ej26D62s3z4jzdWW1yDzg3
Scale=1:16.7
T1
T2
W1
B1
ST1
1
2
3
4
6 5
7
8
9
4x4
1.5x4
2x4 1.5x4 1.5x4
7-11-14
7-11-14
5-10-10
5-10-10
7-11-14
2-1-3
0-4-1
2-5-7
0-1-10
1-5-5
0-1-10
5.0012
LOADING (psf)
TCLL
TCDL
BCLL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
PB06
TrussType
Piggyback
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:432018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-DBZ24lYvvFJ6WZK6mN8SdRG9zdQbbWjEydN42UyDzg2
Scale=1:16.7
T1
T2
W1
B1
ST1
1
2
3
4
6 5
7
8
9
4x4
1.5x4
2x4 1.5x4 1.5x4
7-11-14
7-11-14
5-10-10
5-10-10
7-11-14
2-1-3
0-4-1
2-3-15
0-1-8
1-5-7
0-1-8
5.0012
LOADING (psf)
TCLL
TCDL
BCLL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
PB07
TrussType
Piggyback
Qty
7
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:442018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-hO7QH5ZXgZRy7jvIJ5fhAfoKi1lGKzlNAH6dawyDzg1
Scale=1:19.6
T1 T1
B1
ST1
1
2
3
4
5
6
7
8
9
10
11
12
4x4
2x4 1.5x4 2x4
11-9-5
11-9-5
5-10-10
5-10-10
11-9-5
5-10-10
0-4-1
2-3-15
0-1-8
0-4-1
0-1-8
5.0012
LOADING (psf)
TCLL
TCDL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T01
TrussType
Common
Qty
2
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:452018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-AahoURZ9RsZpltUUtoBwjsLWNR0I3JyWPxsA7MyDzg0
Scale=1:61.6
T1
T2
B1
W3
W4
W3
W1
W2
W6
W5
B2
1
2
3
4
5
6
10 9
8 7
11
12
13
14
15
1.5x4
4x4
3x5
3x8
3x4 4x4
3x5 3x8
3x4
7-9-0
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T01GE
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:462018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-emFBinanCAhgN02hRWi9F4uh9rS?oqsgebbkfoyDzg?
Scale=1:63.0
W1
T1 T1
W1
B1
ST4
ST3
ST2
ST1
ST4
ST3
ST2
ST1
B2
1
2
3
4
5
6
7
8
9
10
11
12
13
24 23 22 21 20 19 18 17 16 15 14
25 26
3x4
3x5
3x4
3x5
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T02
TrussType
PiggybackBaseGirder
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:482018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-a9Nx7Sc1knxOcKC3YwkdKVz0xey7Gahz5v4qihyDzfz
Scale=1:68.4
T1
T2
T1
B1
W3 W4
W5
W6
W5
W7
W5
W4 W3
W1
W2
W9
B2 W8
1
2
3 4 5
6
7
15 14 13 12
11 10 9
8
16
17
18 19
20
21
22 23 24 25 26
3x8
4x8
4x8
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T02
TrussType
PiggybackBaseGirder
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:492018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-2LwJKocgV53FEUnG6eFstiWBh2IM?1x6KZqOF7yDzfy
NOTES-
11) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 1096 lb down and 94 lb up at 2-0-12, 1096 lb down and 94 lb up at
4-0-12, 1096 lb down and 94 lb up at 6-0-12, 1096 lb down and 94 lb up at 8-0-12, and 1096 lb down and 94 lb up at 10-0-12, and 1096 lb down and 94 lb up at 12-0-12
on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
LOADCASE(S) Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-3=-51, 3-5=-61, 5-7=-51, 8-15=-20
Concentrated Loads(lb)
Vert: 13=-1096(B) 22=-1096(B) 23=-1096(B) 24=-1096(B) 25=-1096(B) 26=-1096(B)
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T02GE
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:502018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-WXUhY8dIFPB6reMSgLm5Qw2H0SlHkUPFZDZxnayDzfx
Scale=1:68.4
T1
T2
T3
B1
W3
W4
W5
W6
W5
W7
W5
W4
W3
W1
W2
W1
W2
ST9
ST7
ST8
ST5
ST6
ST3
ST4
ST2
ST1
ST10
ST11
ST12
ST5
ST3
B2
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T02GE
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:512018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-_k23lUew0iJzToxeE3HKy7bSms5WTxfPntJVJ0yDzfw
NOTES-
13) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 58 lb down and 116 lb up at 0-11-5 on top chord, and 19 lb down and
18lb up at 0-11-5, 95 lb down and 57 lb up at 1-0-13, 95 lb down and 58 lb up at 3-0-13, 95 lb down and 58 lb up at 5-0-13, 95 lb down and 58 lb up at 7-0-13, 95 lb
down and 58 lb up at 9-0-13, and 95 lb down and 58 lb up at 10-11-4, and 128 lb down and 60 lb up at 12-5-4 on bottomchord.The design/selection of such
connection device(s)is the responsibility of others.
14)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S) Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-51, 2-4=-51, 4-6=-61, 6-8=-51, 8-9=-51, 10-17=-20
Concentrated Loads(lb)
Vert: 16=-89 42=34(F) 46=-90 47=-89 48=-89 49=-89 50=-89 51=-111
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T03
TrussType
PiggybackBase
Qty
14
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:522018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-SwcSyqfYn0Rq5xWqnmpZVL7ZpFQSCQNY0X22rSyDzfv
Scale=1:65.8
W1
T1
T2
B1
W2 W1
W2
W3
W4
W5
W7
W6
T3
B2
1 2 3
4
5
6
12 11
10 9 8
7
13 14 15
16
17
18
19
1.5x4
4x4 5x6
3x6
3x4
5x8
1.5x4
3x4
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T03AGE
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:542018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-PJkCNWgoJdhYKFgDvBr1amD5V3CNgRqrUrX9wLyDzft
Scale=1:73.5
W1
T1
T2
W3
B1
ST1 ST1 ST1 ST1 ST1 ST2
ST3
ST4
ST5
ST6
ST7
ST8
T3
B2
W2
1 2 3 4 5 6 7
8
9
10
11
12
13
14
15
16
17
32 31 30 29 28
27
26 25 24 23 22 21 20 19 18
33
34
3x4
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T03AGE
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:542018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-PJkCNWgoJdhYKFgDvBr1amD5V3CNgRqrUrX9wLyDzft
NOTES-
10)Gablestudsspaced at 2-0-0 oc.
11)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
12)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 32, 31, 30, 29, 28, 26, 25, 24, 23, 22, 21, 20 except
(jt=lb) 18=160, 19=432.
13)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T03GE
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:552018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-tVIabrhQ4xpPyPEPTvMG7zl9cTTcPu4?iVHiSnyDzfs
Scale=1:73.5
W1
T1
T2
W3
B1
ST1 ST1 ST1 ST1 ST1 ST2
ST3
ST4
ST5
ST6
ST7
ST8
T3
B2
W2
1 2 3 4 5 6 7
8
9
10
11
12
13
14
15
16
31 30 29 28 27
26
25 24 23 22 21 20 19 18 17
32
33
34
5x6
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T03GE
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:562018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-LhsyoBi3rFxFZZpc0ctVfBIJMtpr8LK8x90G_DyDzfr
NOTES-
11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 31, 30, 29, 28, 27, 25, 24, 23, 22, 21, 20, 19 except
(jt=lb) 17=302, 18=331.
12)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T04
TrussType
Common
Qty
5
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:572018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-puPL0XjhcY36BjOoaJOkCOrWWGAYtm?HApmpXgyDzfq
Scale=1:48.7
T1 T1
B1
W1 W2
W3
W2 W1
HW1
W5
1 B2 W4
2
3
4
5
6
7
8
13 12
11 10 9
18
19
20 21
22
23
4x4
3x5
3x4
3x4
3x5
1.5x4
3x8
3x5
4x4 1.5x4
5x6
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T04GE
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:582018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-H4zjDtjJNsCzpsz_81vzkcNhGgZ?cGgROTVM36yDzfp
Scale=1:51.7
T1 T1
W1
B1
ST5
ST4
ST3
ST2
ST1
ST5
ST4
ST3
ST2
HW1
ST1
1 B2
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
28 2726 25 24 23 22 21 20 19 1817
29
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T05
TrussType
CommonGirder
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:592018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-lGX5QDkx8AKqQ0YBikRCHpwoB4mPLc_ad7FwbYyDzfo
Scale=1:48.7
T1 T1
B1
W1 W2
W3
W2 W1
W5
B2 W4
1
2
3
4
5
6
7
12 11
10 9 8
16
17
18 19
20
21
5x6
4x6
4x6
3x5
2x4
3x10
3x5
4x4 3x4
4x8
5-11-0
5-11-0
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T05
TrussType
CommonGirder
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:56:592018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-lGX5QDkx8AKqQ0YBikRCHpwoB4mPLc_ad7FwbYyDzfo
LOADCASE(S) Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-4=-501, 4-6=-91, 6-7=-91, 8-13=-20
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T06
TrussType
PiggybackBase
Qty
5
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:012018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-iffrrvmBgnaYgKiZp9TgME?5NuSWpX3t5Rk1gRyDzfm
Scale=1:78.3
T1
T2
T3
B1
W3
W4 W5
W6 W6
W5
W7
W8
W1
W2 W10
W9
T4
B2 B3
1
2
3 4 5
6
7
8
9
17 16 15 14
13 12
11 10
18
19
20
21
22
23
24
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T06
TrussType
PiggybackBase
Qty
5
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:012018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-iffrrvmBgnaYgKiZp9TgME?5NuSWpX3t5Rk1gRyDzfm
LOADCASE(S) Standard
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T06GE
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:032018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-e2ncGbnSCOqGvesyxaV8Rf5SvhB9HQaAYlD7kJyDzfk
Scale=1:83.4
T1
T2
T3
B1
W4
W3
W5
W8
W1
W2
W10
W9
W6
W6
W5 W7
T4
B2 B3
ST13
ST14
ST11
ST12
ST10
ST8
ST9
ST6
ST7
ST5
ST3
ST4
ST1
ST2
ST13
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T06GE
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:042018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-6EK_Uwo4yiy7XnQ8UI0N_tddf5XO0tqJnPyhHmyDzfj
NOTES-
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 25 except(jt=lb) 19=159, 22=135, 10=199, 18=490,
11=126.
12)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T07
TrussType
PiggybackBase
Qty
5
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:052018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-aQuMhGpij04_8x?K2?XcX4AnkVsmlJfT?2iEpCyDzfi
Scale=1:66.8
W1
T1
T2
B1
W2
W3
W4
W5
W7
W6
T3
B2
1 2
3
4
5
6
11 10
9 8
7
12 13 14
15
16
17
3x4
3x4 5x6
3x4
3x4 3x4
3x5
4x4 3x4
6x12MT18H
6-0-12
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T08
TrussType
PiggybackBaseGirder
Qty
1
Ply
3
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:072018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-Wp076yqyFdKiOF9jAQa4cVF6OIWzD9FmTMBLt5yDzfg
Scale=1:59.5
T2
T3
W7
B1
W1 W2
W3 W4
W5 W6
W7 W8
W7 W8
T1
B2
1 HW1
2
3
4 5
6
7 8 9
16 15 14
13 12 11 10
21
22
23
24 25 26 27 28 29 30 31 32 33 34 35 36
5x10
1.5x4
8x8
6x16MT18H
5x6
6x8
3x4
3x6 8x8 10x10
5x8
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T08
TrussType
PiggybackBaseGirder
Qty
1
Ply
3
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:072018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-Wp076yqyFdKiOF9jAQa4cVF6OIWzD9FmTMBLt5yDzfg
NOTES-
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 10=1714, 1=1549.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
11) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 1140 lb down and 215 lb up at 2-0-12, 1140 lb down and 215 lb up at
4-0-12, 1140 lb down and 215 lb up at 6-0-12, 1140 lb down and 215 lb up at 8-0-12, 1140 lb down and 215 lb up at 10-0-12, 1140 lb down and 215 lb up at 12-0-12,
1140lb down and 215 lb up at 14-0-12, 1140 lb down and 215 lb up at 16-0-12, 1140 lb down and 215 lb up at 18-0-12, 1140 lb down and 215 lb up at 20-0-12, 1140 lb
down and 215 lb up at 22-0-12, 1140 lb down and 215 lb up at 24-0-12, and 1140 lb down and 215 lb up at 26-0-12, and 1142 lb down and 213 lb up at 28-0-12 on
bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
LOADCASE(S) Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-7=-51, 7-9=-61, 10-17=-20
Concentrated Loads(lb)
Vert: 13=-1140(F) 24=-1140(F) 25=-1140(F) 26=-1140(F) 27=-1140(F) 28=-1140(F) 29=-1140(F) 30=-1140(F) 31=-1140(F) 32=-1140(F) 33=-1140(F) 34=-1140(F)
35=-1140(F) 36=-1142(F)
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T09
TrussType
PiggybackBase
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:082018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-_?aVJIra0xSZ?Pkvj75J8joLrirlyfdvi0wuQXyDzff
Scale=1:63.3
T2
T3
W7
B1
W3 W4
W5
W6 W7 W8
W9
W1
W2
T1
B2
1
2
3
4
5 6 7
13 12 11
10 9
8
14
15
16
17
1819 20
3x4
4x6 1.5x4
3x4 3x4 3x4
3x4
5x6
3x4
3x4
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T10
TrussType
PiggybackBase
Qty
7
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:102018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-xOiFk_trYYiGFiuIrY7nD8tf6WV1QUnC9KP?UPyDzfd
Scale=1:71.0
T2
T3
T4
B1
W3 W4
W5
W6 W7
W8
W7 W8 W7
W1
W2
W10
W9
T1
B2 B1
1
2
3
4
5 6 7
8
17 16 15 14
13 12
11 10 9
18
19
20
21
22 23 24
25
26
3x6
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T11
TrussType
Hip
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:112018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-PaGdyKtTJsq7tsTUPGe0mLQwswtC9y1LO_9Y0syDzfc
Scale=1:91.9
0-1-10
0-1-10
T2
T3
T4
B1
B2
B3
W1
W2
W3
W5
W4
W6 W7
W8
W9
W10
W9
W11
W12
W13
W14
HW1
HW1
T1
T5
B4 B5
1
2 3
4
5 6
7
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T11
TrussType
Hip
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:122018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-tmp09gu549y_U02gyzAFJZy4cJDRuPGVceu6ZIyDzfb
NOTES-
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 1=287, 14=266.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T12
TrussType
Hip
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:132018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-LzNOM?vjrT4r6AdtWghUrmVFXjaGdtverIef5kyDzfa
Scale=1:91.9
0-1-10
0-1-10
T2
T3
T4
B1
B2
B3
W1
W2
W3
W5
W4
W6 W7
W8
W9
W10
W11 W10 W9
W12
W13
W14
W15
HW1
HW1
T1
T5
B4 B5
1
2 3
4
5
6
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T12
TrussType
Hip
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:132018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-LzNOM?vjrT4r6AdtWghUrmVFXjaGdtverIef5kyDzfa
NOTES-
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 1=272, 15=248.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T13
TrussType
Hip
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:152018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-HLV8nhxzN4LZLUmFe5jywBabeXGi5ntxJc7m9dyDzfY
Scale=1:92.1
0-1-10
0-1-10
T2
T3
T4
B1
B2
B3
W1
W2
W3
W5
W4
W6 W7
W8
W9
W10
W11 W10 W9
W12 W13
W14
W15
HW1
HW1
T5
B4 B5
1
2 3
4 5
6
7
8
9 10 11
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T13
TrussType
Hip
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:152018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-HLV8nhxzN4LZLUmFe5jywBabeXGi5ntxJc7m9dyDzfY
NOTES-
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 2=276, 16=228.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T14
TrussType
Roof Special
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:172018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-EkdvCNyEvibHbnwelWlQ0cgzTKynZi8EmwctEVyDzfW
Scale=1:92.1
0-1-10
0-1-10
T2
T3
T4
T5
B1
B2
B3
W1
W2
W3
W5
W4
W6 W7 W8
W9 W8 W9
W8 W10
W11
W12
W13 W14
W15
W16
HW1
HW1
T6
B4
1
2 3
4 5
6
7
8 9 10
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T14
TrussType
Roof Special
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:172018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-EkdvCNyEvibHbnwelWlQ0cgzTKynZi8EmwctEVyDzfW
NOTES-
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 2=361, 17=234.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T15
TrussType
Roof Special
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:192018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-A7kfd3_UQJr?q541txou51lJ_8eG1chXDE5zIOyDzfU
Scale=1:92.1
0-1-10
0-1-10
T2
T3
T4
T5
B1
B2
B3
W1
W2
W3
W5
W4
W6
W7
W8 W9 W8
W10
W11
W12
W13 W14
W15
W16
HW1
HW1
T6
B4
1
2 3
4 5
6
7
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T15
TrussType
Roof Special
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:192018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-A7kfd3_UQJr?q541txou51lJ_8eG1chXDE5zIOyDzfU
NOTES-
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 2=361, 16=234.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T16
TrussType
Roof Special
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:212018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-6VsP2k?kyw5i3PEP_MqMASqgQyGDVUFphYa4NHyDzfS
Scale=1:100.2
0-1-10
0-1-10
0-1-10
0-1-10
T2
T3
T4
T5
T6
B1
B2
B3
W1
W2 W3
W5
W4
W6
W7
W8
W7
W9 W10
W11
W12
W13
W14
W15
W14
W16 W17
W18
W19
T1
T7
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T16
TrussType
Roof Special
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:212018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-6VsP2k?kyw5i3PEP_MqMASqgQyGDVUFphYa4NHyDzfS
NOTES-
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 2=363, 19=229.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T17
TrussType
Roof Special
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:242018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-W4YYgm2dFrTHwsy_fUN3o5S9w9M8iqSGNWok_byDzfP
Scale=1:98.5
0-1-10
0-1-10
0-1-10
0-1-10
W1
T1
T2
T3
T4
T5
B1
B2
B3
W2 B4
W3 W4
W5 W6
W7 W8
W9
W11
W10
W12W13W12 W14
W15
W16
W17
W18 W19 W18
W20 W21
W22 W23
HW2
T6
B5 B6
F2 F4
F3 F3
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T17
TrussType
Roof Special
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:242018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-W4YYgm2dFrTHwsy_fUN3o5S9w9M8iqSGNWok_byDzfP
NOTES-
5)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flatroofsnow: Lumber DOL=1.15Plate
DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than
0.500/12in accordancewithIBC 1608.3.4.
6) Unbalancedsnowloads have been considered for this design.
7)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads.
8)Provide adequate drainage to preventwater ponding.
9)All plates are 4x4MT20 unless otherwiseindicated.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11)Bearing at joint(s) 34 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverifycapacity of bearingsurface.
12)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 34=349, 17=207.
13)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T18
TrussType
Roof Special
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:272018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-xfDgJo4VYmrsnKhZLdxmQj4j0MLhvDOi3U1PbwyDzfM
Scale=1:93.7
0-1-10
0-1-10
0-1-10
0-1-10
W1
T1
T2
T3
T4
T5
B1
B2
B3
W2 B4
W3 W4
W5 W6
W7 W8
W9
W11
W10 W12W13W12W14
W15
W16
W17
W18 W19W20W19 W18
W21 W22
W23 W24
B5 B6 HW2
F2 F4
F3 F3
1 2
3
4
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T18
TrussType
Roof Special
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:272018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-xfDgJo4VYmrsnKhZLdxmQj4j0MLhvDOi3U1PbwyDzfM
NOTES-
4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-C
Exterior(2)-0-10-12 to 4-0-1,Interior(1) 4-0-1 to 11-2-0,Exterior(2) 11-2-0 to 16-0-13,Interior(1) 21-2-6 to 36-6-0,Exterior(2) 36-6-0 to 41-4-13zone;cantileverleft and
right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
5)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flatroofsnow: Lumber DOL=1.15Plate
DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than
0.500/12in accordancewithIBC 1608.3.4.
6) Unbalancedsnowloads have been considered for this design.
7)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads.
8)Provide adequate drainage to preventwater ponding.
9)All plates are 4x4MT20 unless otherwiseindicated.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11)Bearing at joint(s) 35 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverifycapacity of bearingsurface.
12)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 35=336, 17=223.
13)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T19
TrussType
Roof Special
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:302018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-LEvpxp6NrhERenQ80lUT1MiFDaI86Yw8lRF3BFyDzfJ
Scale=1:93.9
0-1-10
0-1-10
0-1-10
0-1-10
W1
T1
T2
T3
T4
T5
B1
B2
B3
W2 B4
W3 W4
W5 W6
W7 W8W9
W11
W10
W12
W13
W12
W14
W15
W16
W17
W18 W19W20W21W20W19 W18
W22 W23
W24 W25
B5 B6 HW2
F2 F4
F3 F3
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T19
TrussType
Roof Special
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:302018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-LEvpxp6NrhERenQ80lUT1MiFDaI86Yw8lRF3BFyDzfJ
NOTES-
4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;MWFRS(envelope) gable end zone and C-C
Exterior(2)-0-10-12 to 4-0-1,Interior(1) 4-0-1 to 9-2-0,Exterior(2) 9-2-0 to 14-0-13,Interior(1) 19-2-6 to 38-6-0,Exterior(2) 38-6-0 to 43-4-13zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
5)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flatroofsnow: Lumber DOL=1.15Plate
DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than
0.500/12in accordancewithIBC 1608.3.4.
6) Unbalancedsnowloads have been considered for this design.
7)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads.
8)Provide adequate drainage to preventwater ponding.
9)All plates are 2x4MT20 unless otherwiseindicated.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11)Bearing at joint(s) 37 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverifycapacity of bearingsurface.
12)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 37=324, 18=251.
13)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T20
TrussType
Hip
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:312018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-pQTB8970c?MIGx?KaS?iaZFJh_iqr2vI_5?ckhyDzfI
Scale=1:55.8
0-1-10
0-1-10
T1
T2
T4
B1
W3 W4 W5 W4 W5 W4 W3
W1 W2 W6 W7
W8 W9
T3
B2
1
2 3 4 5 6
7
8
9
17 16 15 14
13 12 11 10
18
19 20 2122
23
24
6x6
3x4
3x8 3x8 3x5
3x4
1.5x4
3x10
6x6
3x4
3x4
5x6
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T21
TrussType
HipGirder
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:332018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-mpbyZr8G7cc0VF8jht2Af_KbmnLDJwJbSPUjoayDzfG
Scale=1:56.5
0-1-10
0-1-10
T1
T2
T4
B1
W3 W4 W5 W4 W5 W4 W5 W4 W3
W1 W6 W7
W2
W8 W9
T3
B2
1
2 3 4 5 6 7
8
9
10
19 18 17 16 15
14 13 12 11
20
6x6
3x6
3x8 5x6
4x6 5x6
3x5
3x10
1.5x4 3x4
3x5
6x6
3x4
3x4
6x6
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T21
TrussType
HipGirder
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:332018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-mpbyZr8G7cc0VF8jht2Af_KbmnLDJwJbSPUjoayDzfG
NOTES-
12) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 813 lb down and 316 lb up at 26-5-4 on bottomchord.The
design/selection of suchconnection device(s)is the responsibility of others.
13)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S) Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-51, 2-7=-61, 7-9=-51, 9-10=-51, 11-19=-20
Concentrated Loads(lb)
Vert: 12=-813(B)
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T22
TrussType
Hip
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:342018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-E?8KnB9uuwks7OjvFbZPCCtscBfb2Lfkg3DGK0yDzfF
Scale=1:49.5
0-1-10
0-1-10
T1 T2 T4
B1
W1 W3 W4 W3 W4 W3 W4 W3 W4 W3 W4 W3 W6
T3
B2
W2 W5
1 2 3 4 5 6
7 8 9
18 17 16 15
14 13 12 11
10
19 20
10x14MT18H 4x6
6x10
5x6
4x6 3x10MT18H
4x4
4x8
3x5
4x8
2x4 3x4
3x5
3x5
4x8 4x6
3x6
0-7-8
0-7-8
5-8-6
5-0-14
10-7-7
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T23
TrussType
HalfHipGirder
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:392018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-azyDquD1jSM9EAct289avFalMCV3jeETqLx10EyDzfA
Scale=1:54.8
0-1-10
W1
T1
T3
B1
W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W3
HW2
T2
B2
1 2 3 4 5 6 7 8 9
10 11
19 18 17 16 15
14 13 12
24 25 26 27 28 293031 32 33 34 35 36
37 38 39 40 41 42 43 44 45 46 47 4849
3x4
6x6 6x8
6x6 5x6
5x6
5x6
4x6
4x8
3x6 4x6
4x4
4x6
6x6
8x8
2x4 3x12MT18H
4x4
4-9-1
4-9-1
9-4-7
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T23
TrussType
HalfHipGirder
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:392018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-azyDquD1jSM9EAct289avFalMCV3jeETqLx10EyDzfA
NOTES-
6) Unbalancedsnowloads have been considered for this design.
7)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs non-concurrentwith otherliveloads.
8)Provide adequate drainage to preventwater ponding.
9)All plates areMT20 plates unless otherwiseindicated.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11) Refer to girder(s) for truss to trussconnections.
12)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb) 19=766, 10=1012.
13)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
14) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 22 lb down and 43 lb up at 1-7-4, 22 lb down and 43 lb up at 3-7-4,
22lb down and 43 lb up at 5-7-4, 22 lb down and 43 lb up at 7-7-4, 22 lb down and 43 lb up at 9-7-4, 22 lb down and 43 lb up at 11-7-4, 22 lb down and 43 lb up at
13-7-4, 22 lb down and 43 lb up at 15-7-4, 22 lb down and 43 lb up at 17-7-4, 22 lb down and 43 lb up at 19-7-4, 22 lb down and 43 lb up at 21-7-4, 22 lb down and 43
lb up at 23-7-4, and 22 lb down and 43 lb up at 25-7-4, and 42 lb down and 116 lb up at 27-8-0 on top chord, and 12 lb down and 32 lb up at 1-7-4, 12 lb down and 32
lb up at 3-7-4, 12 lb down and 32 lb up at 5-7-4, 12 lb down and 32 lb up at 7-7-4, 12 lb down and 32 lb up at 9-7-4, 12 lb down and 32 lb up at 11-7-4, 12 lb down and
32lb up at 13-7-4, 12 lb down and 32 lb up at 15-7-4, 12 lb down and 32 lb up at 17-7-4, 12 lb down and 32 lb up at 19-7-4, 12 lb down and 32 lb up at 21-7-4, 12 lb
down and 32 lb up at 23-7-4, 12 lb down and 32 lb up at 25-7-4, and 780 lb down and 302 lb up at 26-5-4, and 44 lb down and 75 lb up at 27-7-4 on bottomchord.The
design/selection of suchconnection device(s)is the responsibility of others.
LOADCASE(S) Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-8=-61, 8-11=-51, 19-20=-20
Concentrated Loads(lb)
Vert: 17=-2(B) 12=-1(B) 37=-2(B) 38=-2(B) 39=-2(B) 40=-2(B) 41=-2(B) 42=-2(B) 43=-2(B) 44=-2(B) 45=-2(B) 46=-2(B) 47=-2(B) 48=-2(B) 49=-780(F)
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T24
TrussType
HalfHipGirder
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:412018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-XL4zFaFHF4ctTTmF9ZB2_gf4005gBWKmHfQ846yDzf8
Scale=1:20.4
0-1-10
T1
T2
W7
B1
W3 W4
W5 W6 W7
W6
W1
W2
1
2
3
4 5 6
11
10 9 8
7
12
13 14
15 16
5x6
7x14MT18H 3x10
3x4
4x8 6x6
1.5x4
8x8
6x6
2-7-8
2-7-8
3-9-0
1-1-8
6-7-12
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T24
TrussType
HalfHipGirder
Qty
1
Ply
2
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:412018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-XL4zFaFHF4ctTTmF9ZB2_gf4005gBWKmHfQ846yDzf8
NOTES-
13) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 60 lb down and 100 lb up at 3-9-0, 55 lb down and 72 lb up at 4-8-4,
and 56 lb down and 72 lb up at 6-8-4, and 49 lb down and 32 lb up at 8-8-4 on top chord, and 1619 lb down and 786 lb up at 2-7-8, 32 lb down and 68 lb up at 3-9-0,
1313lb down and 487 lb up at 4-8-4, 28 lb down and 43 lb up at 4-8-4, 1465 lb down and 562 lb up at 6-8-4, 28 lb down and 43 lb up at 6-8-4, and 1243 lb down and
500lb up at 8-8-4, and 65 lb down and 53 lb up at 8-8-4 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
LOADCASE(S) Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-51, 2-4=-51, 4-6=-61, 7-11=-20
Concentrated Loads(lb)
Vert: 4=-30(F) 10=-1619(B) 9=-16(F) 5=-24(F) 8=-1485(F=-21,B=-1465) 13=-24(F) 14=-18(F) 15=-1334(F=-21,B=-1313) 16=-1307(F=-65,B=-1243)
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T25
TrussType
HalfHipGirder
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:422018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-?YdLSwFv0Nkk5dKRjGiHWuC9VPMUwAqvWJ9hdZyDzf7
Scale=1:16.8
0-1-10
T1 T2
W4
B1
W2 W3
W1
1
2 3
6
5 7 4
2x4
5x6
2x4
4x4
5x6
4x6
0-11-0
0-11-0
3-10-8
2-11-8
0-11-0
0-11-0
3-10-8
2-11-8
2-4-11
2-7-10
2-9-4
2-7-10
5.0012
LOADING (psf)
TCLL
TCDL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T26
TrussType
HalfHip
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:442018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-xwl6tcH9Y?_SKxUqqhklcJHXJD9VOwPCzdeohRyDzf5
Scale=1:32.7
0-1-10
T1
T2
W11
B1
B2 B3
B4
B1
W3 W5
W4 W6
W7 W8
W10
W9
W1
W2
1
2
3
4
5 6 7
15
14 13
12
11
10
9
8
16
17
18 19
6x6
1.5x4 1.5x4 3x4
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T27
TrussType
HalfHip
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:452018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-P7JU4yIoJI7Jy530OPF_8WqhFdWR7STMCHOMDuyDzf4
Scale=1:29.1
0-1-10
T1
T2
W11
B1
B2 B3
B4
B1
W3
W5
W4 W6
W7 W8
W10
W9
W1
W2
1
2
3
4
5 6 7
15
14 13
12
11
10
9
8
16
17 18 19
6x6
1.5x4 1.5x4 3x4
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T28
TrussType
HalfHip
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:462018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-tJtsIIJQ3cF9ZEeDy6nDhkNxX1rFsvqVRx7vmKyDzf3
Scale=1:28.2
0-1-10
T1
T2
W12
B1
B2 B3
B4
B1
W3 W5
W4
W6
W7 W8 W9 W8
W11
W10
W1
W2
1
2
3
4
5 6 7 8
17
16 15
14
13 12
11
10
9
18 19
6x6
1.5x4 3x4
1.5x4
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T29
TrussType
HalfHipGirder
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:482018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-pi?djzKgbDVtpYob3Xphm9SHWqWJKmpouFc0qCyDzf1
Scale=1:27.9
0-1-10
T1
T2
W5
B1
W3 W4 W5 W4 W5 W4
W1 W2
1
2
3 4 5 6
11
10 9 8
7
12 13 14 15 16
17 18 19 20 21
6x6
1.5x4 2x4
3x4 3x4
3x4 1.5x4
4x10
3x8
3x4
2-4-8
2-4-8
6-6-9
4-2-1
10-10-7
4-3-13
15-4-0
4-5-9
-0-10-12
0-10-12
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
T29
TrussType
HalfHipGirder
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:482018 Page2
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-pi?djzKgbDVtpYob3Xphm9SHWqWJKmpouFc0qCyDzf1
LOADCASE(S) Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-51, 2-3=-51, 3-6=-61, 7-11=-20
Concentrated Loads(lb)
Vert: 10=1(B) 9=-0(B) 16=-1(B) 17=-0(B) 18=-0(B) 19=-0(B) 20=-0(B) 21=-3(B)
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V01
TrussType
Valley
Qty
2
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:492018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-IuY?wJLIMXdkQiNodEKwJM?SAEyv3Jlx7vMZMfyDzf0
Scale=1:75.2
T2
W1
B1
ST2
ST1
T1
1
2
3
4
5
8 7 6
9
10
11
3x4
1.5x4
1.5x4
3x4
1.5x4
1.5x4
1.5x4
1.5x4
13-2-11
13-2-11
13-2-11
13-2-11
0-0-4
13-2-11
12.0012
LOADING (psf)
TCLL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V02
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:502018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-m46N7fMw7rlb2sy_Byr9raXf9eJ6ok35MZ56v5yDzf?
Scale=1:72.6
T2 T2
B1
ST3
ST2
ST1
ST2
ST1
T1 T1
B2
1
2
3
4
5
6
7
8
9
14 13 12 11 10
15
16
17 18
19
20
3x4
4x4
3x4
3x4
5x6
3x4
0-0-4
0-0-4
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V03
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:512018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-EHglL?MYu8tSg0WAlfMOOn4qt2fTXCtEaDrgRXyDzf_
Scale:3/16"=1'
T1 T1
B1
ST3
ST2
ST1
ST2
ST1
B2
1
2
3
4
5
6
7
13 12 11 10 9 8
14
15
16 17
18
19
3x4
4x4
3x4
3x4
21-1-2
21-1-2
21-1-6
0-0-4
10-6-11
10-6-11
21-1-6
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V04
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:522018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-iTE7YLNBfS?JH95MINtdw?dzIRzbGgLOpsaDy_yDzez
Scale=1:60.8
T1 T1
B1
ST2
ST1 ST1
B2
1
2
3
4
5
9 8 7 6
10
11
12 13
14
15
3x4
4x4
3x4
3x4 1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
0-0-4
0-0-4
18-5-6
18-5-2
9-2-11
9-2-11
18-5-6
9-2-11
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V05
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:532018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-AfoWmhOpQm7AvJgZs4PsTC9AFrKx?8BX2WKnUQyDzey
Scale=1:48.9
T1 T1
B1
ST2
ST1 ST1
1
2
3
4
5
8 7 6
9
10
11 12
13
14
3x4
4x4
3x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
0-0-4
0-0-4
15-9-6
15-9-2
7-10-11
7-10-11
15-9-6
7-10-11
0-0-4
7-10-11
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V06
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:542018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-erMuz1PRB3F1XTFlQow50QiLQFg4kcIgHA3K1syDzex
Scale=1:42.7
T1 T1
B1
ST2
ST1 ST1
1
2
3
4
5
8 7 6
9
10 11
12
3x4
4x4
3x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
13-1-2
13-1-2
13-1-6
0-0-4
6-6-11
6-6-11
13-1-6
6-6-11
0-0-4
6-6-11
0-0-4
12.0012
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V07
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:552018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-62wGBNQ3yNNu8dqx_VRKYdESkf_jT3pqVqptZIyDzew
Scale=1:34.5
T1 T1
B1
ST1
1
2
3
4
5
6
7 8
9
10
2x4
4x4
2x4
1.5x4
0-0-4
0-0-4
10-5-6
10-5-2
5-2-11
5-2-11
10-5-6
5-2-11
0-0-4
5-2-11
0-0-4
12.0012
LOADING (psf)
TCLL
TCDL
BCLL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V08
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:562018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-aEUeOiQhjgVlmnP8XCyZ5rngr3MTCXszkUYR5lyDzev
Scale=1:27.1
T1 T1
B1
ST1
1
2
3
4
5
6
7
8
2x4
4x4
1.5x4 2x4
0-0-4
0-0-4
7-9-6
7-9-2
3-10-11
3-10-11
7-9-6
3-10-11
0-0-4
3-10-11
0-0-4
12.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V09
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:572018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-3Q10c2RJU_dcOx_K5wTod2KtpSjlx_S7z8I_dByDzeu
Scale=1:18.6
T1 T1
B1
ST1
1
2
3
4
2x4
4x4
1.5x4 2x4
0-0-4
0-0-4
5-1-6
5-1-2
2-6-11
2-6-11
5-1-6
2-6-11
0-0-4
2-6-11
0-0-4
12.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V10
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:582018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-XdbPpOSyFIlS?4ZWfd_1AGs3es3CgR0GBo1YAdyDzet
Scale=1:8.9
T1 T1
B1
1
2
3
2x4
3x4
2x4
0-0-4
0-0-4
2-5-6
2-5-2
1-2-11
1-2-11
2-5-6
1-2-11
0-0-4
1-2-11
0-0-4
12.0012
PlateOffsets(X,Y)-- [2:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V11
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:57:592018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-?p9n0kTa0btJdE8jDLVHjTPDsGOUPsrPQSn5i4yDzes
Scale=1:71.7
T2
W1
B1
ST9
ST8
ST7
ST6
ST5
ST4
ST3
ST1 ST2
T1
B2
1
2
3
4
5
6
7
8
9
10
11
12
22 21 20 19 18 17 16 15 14 13
3x4
3x4
5x6
20-3-6
20-3-6
20-3-6
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V12
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:002018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-T?j9E4TCmv?AFOivm21WFhyL4gjR8HTZf6WeEWyDzer
Scale=1:67.3
T2
W1
B1
ST4
ST3
ST2
ST1
T1
B2
1
2
3
4
5
6
7
13 12 11 10 9 8
14
15
3x4
3x4
3x4
19-0-6
19-0-6
19-0-6
19-0-6
0-0-4
12-8-4
8.0012
LOADING (psf)
TCLL
TCDL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V13
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:012018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-xCHXRQUqXD81sYH5KmYlouUVU42NtmwiumGCmyyDzeq
Scale=1:59.9
T2
W1
B1
ST3
ST2
ST1
T1
B2
1
2
3
4
5
6
11 10 9 8 7
12
13
3x4
3x4
3x4
17-9-6
17-9-6
17-9-6
17-9-6
0-0-4
11-10-4
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V14
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:022018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-POrvfmVSIWGuUisHuT3_K61hiTPocAWs6Q?lJOyDzep
Scale=1:55.7
T2
W1
B1
ST3
ST2
ST1
T1
B2
1
2
3
4
5
6
11 10 9 8 7
12
13
14
3x4
3x4
3x4
16-6-6
16-6-6
16-6-6
16-6-6
0-0-4
11-0-4
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V15
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:032018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-taPHs6W43qOl6sRUSBaDtJatdtlALeW?L4lJrryDzeo
Scale=1:49.2
T2
W1
B1
ST3
ST2
ST1
T1
1
2
3
4
5
6
10 9 8 7
11
3x4
3x4
15-3-6
15-3-6
15-3-6
15-3-6
0-0-4
10-2-4
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V16
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:042018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-Lnzg4RXiq8Wcj00g?u5SQX6?JH3k46A9akUsNHyDzen
Scale=1:57.0
T2
W1
B1
ST2
ST1
T1
1
2
3
4
5
8 7 6
9
10
3x4
1.5x4
1.5x4
3x4
1.5x4
1.5x4
1.5x4
1.5x4
14-0-6
14-0-6
14-0-6
14-0-6
0-0-4
9-4-4
8.0012
LOADING (psf)
TCLL
TCDL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V17
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:052018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-qzW2HnXLbReTL9bsZbchykf9ShOIpYkIoOEPwjyDzem
Scale=1:51.6
T1 W1
B1
ST2
ST1
1
2
3
4
7 6 5
8
9 10
3x4
3x4
1.5x4 3x4
1.5x4
1.5x4
1.5x4
12-9-6
12-9-6
0-0-4
8-6-4
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V18
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:062018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-I94QU7YzMlmKzJA37J8wVyCIP5mnY0rR12zzSAyDzel
Scale=1:47.1
T1 W1
B1
ST2
ST1
1
2
3
4
7 6 5
8
9
3x4
1.5x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
11-6-6
11-6-6
0-0-4
7-8-4
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V19
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:062018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-I94QU7YzMlmKzJA37J8wVyCGC5mjY1RR12zzSAyDzel
Scale=1:42.1
T1 W1
B1
ST2
1 ST1
2
3
4
7 6 5
8
9
10
2x4
1.5x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
10-3-6
10-3-6
0-0-4
6-10-4
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V20
TrussType
GABLE
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:072018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-mMeoiTZb73uBbTlFh0f919kUeU5MHUubGijW_cyDzek
Scale=1:38.4
T1 W1
B1
ST1
1
2
3
5 4
6
7
8
2x4
1.5x4
1.5x4 1.5x4
1.5x4
9-0-6
9-0-6
0-0-4
6-0-4
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V21
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:082018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-EYCAvpaDuM02CdKREkAOaNHhfuSG0xUkVMS3W2yDzej
Scale=1:32.8
T1
W1
B1
ST1
1
2
3
5 4
6
7
2x4
1.5x4
1.5x4 1.5x4
1.5x4
7-9-6
7-9-6
0-0-4
5-2-4
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V22
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:092018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-ikmZ79arfg8vqnveoRhd7aquGIoflPnuj0Cd3VyDzei
Scale=1:27.9
T1
W1
B1
ST1
1
2
3
5 4
6
7
8
2x4
1.5x4
1.5x4 1.5x4
1.5x4
6-6-6
6-6-6
0-0-4
4-4-4
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V23
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:102018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-AwKxKVbTQ_GmSxTqM9CsfoM11i6uUs_1ygxAbxyDzeh
Scale=1:22.4
T1
W1
B1
1
2
3
4
5
6
2x4
1.5x4
1.5x4
5-3-6
5-3-6
0-0-4
3-6-4
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V24
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:112018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-e7uJYrc5BHOc3420wsj5C?vFd6TuDJEABKhk7NyDzeg
Scale=1:16.4
T1
W1
B1
1
2
3
4
2x4
1.5x4
1.5x4
4-0-6
4-0-6
0-0-4
2-8-4
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V25
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:122018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-6JRhlBdkybWThEdCTaEKkDSP_VotymUKP_QHfpyDzef
Scale=1:17.0
T1
W1
B1
1
2
3
4
2x4
1.5x4
1.5x4
4-2-13
4-2-13
0-0-4
2-9-14
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V26
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:122018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-6JRhlBdkybWThEdCTaEKkDSSOVqNymUKP_QHfpyDzef
Scale=1:11.6
T1
W1
B1
1
2
3
2x4
1.5x4
1.5x4
2-7-5
2-7-5
0-0-4
1-8-14
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V27
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:132018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-bV?3yWdMjveKJOCP1HmZHQ_bQv9YhDkTeeAqCGyDzee
Scale=1:15.8
T1
W1
B1
1
2
3
2x4
1.5x4
1.5x4
3-10-5
3-10-5
0-0-4
2-6-14
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V28
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:142018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-3iZSAse_TCmBwYnbb_HopeXjTJT6Qg_dtIvOkiyDzed
Scale=1:21.5
T1
W1
B1
1
2
3
4
5
2x4
1.5x4
1.5x4
5-1-5
5-1-5
0-0-4
3-4-14
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V29
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:152018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-Xu7qNCfcEWu2YiMn9io1Mr3wzjr397Hm6xfxG8yDzec
Scale=1:27.2
T1
W1
B1
ST1
1
2
3
5 4
6
7
8
2x4
1.5x4
1.5x4 1.5x4
1.5x4
6-4-5
6-4-5
0-0-4
4-2-14
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V30
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:162018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-?4hCbYgE?q0vAsx_iPJGv3c2w7BBuZTwKbOVobyDzeb
Scale:3/8"=1'
T1
W1
B1
ST1
1
2
3
5 4
6
7
2x4
1.5x4
1.5x4 1.5x4
1.5x4
7-7-5
7-7-5
0-0-4
5-0-14
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V31
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:172018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-THFaouhsm79mn?WAG7qVRG9FXWWvd1j3ZF82L1yDzea
Scale=1:12.4
T1
W1
B1
1
2
3
4
2x4
1.5x4
1.5x4
4-7-8
4-7-8
0-0-4
1-11-2
5.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
DE Job # 62831-W1
Dansco Engineering, LLC
Date: 11/30/18
WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!!
This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss
engineer. Permanent bracing
requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing
design shall be the
responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for
Metal Plate Connected Wood
Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood
Trusses” for additional
information.
Job
1803054-12T
Truss
V32
TrussType
Valley
Qty
1
Ply
1
1803054-12TDWH Jackson'sGrantLot117
Job Reference (optional)
Run:8.200 s Apr72018 Print:8.200 s Apr72018MiTekIndustries,Inc.FriNov3014:58:172018 Page1
ID:0sl2?b7GGKmI8OMqWkf_tizP6AS-THFaouhsm79mn?WAG7qVRG9GGWXRd1m3ZF82L1yDzea
Scale=1:20.8
T1
W1
B1
ST1
1
2
3
5 4
6
7
2x4
1.5x4
1.5x4 1.5x4
1.5x4
7-9-14
7-9-14
0-0-4
3-3-2
5.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.18
0.11
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 22 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=73/7-9-5(min. 0-1-8), 4=108/7-9-5(min. 0-1-8), 5=309/7-9-5(min. 0-1-8)
Max Horz1=127(LC 13)
Max Uplift4=-24(LC 16), 5=-105(LC 16)
MaxGrav1=85(LC 30), 4=122(LC 2), 5=350(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 2-5=-262/199
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-9-1 to 3-9-14,Interior(1) 3-9-14 to 7-8-2zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 4 except(jt=lb)
5=105.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.22
0.14
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 12 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-7-8 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=132/4-6-14(min. 0-1-8), 3=132/4-6-14(min. 0-1-8)
Max Horz1=68(LC 13)
Max Uplift1=-24(LC 16), 3=-38(LC 16)
MaxGrav1=149(LC 2), 3=149(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-9-1 to 3-9-1,Interior(1) 3-9-1 to 4-5-12zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.34
0.11
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 26 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=75/7-6-15(min. 0-1-8), 4=108/7-6-15(min. 0-1-8), 5=311/7-6-15(min. 0-1-8)
Max Horz1=185(LC 13)
Max Uplift1=-13(LC 12), 4=-40(LC 13), 5=-153(LC 16)
MaxGrav1=121(LC 30), 4=142(LC 29), 5=378(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-6=-273/261, 2-6=-256/265
WEBS 2-5=-306/207
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-7-5,Interior(1) 3-7-5 to 7-5-9zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 4 except(jt=lb)
5=153.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.23
0.10
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 21 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=14/6-3-15(min. 0-1-8), 4=111/6-3-15(min. 0-1-8), 5=281/6-3-15(min. 0-1-8)
Max Horz1=152(LC 13)
Max Uplift1=-38(LC 14), 4=-36(LC 13), 5=-138(LC 16)
MaxGrav1=78(LC 13), 4=144(LC 29), 5=341(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-6=-252/236
WEBS 2-5=-279/199
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-5-12,Interior(1) 3-5-12 to 6-2-9zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 4 except(jt=lb)
5=138.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.34
0.21
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-1-5 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=159/5-0-15(min. 0-1-8), 3=159/5-0-15(min. 0-1-8)
Max Horz1=119(LC 15)
Max Uplift1=-17(LC 16), 3=-58(LC 16)
MaxGrav1=179(LC 2), 3=200(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-5-12,Interior(1) 3-5-12 to 4-11-9zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.17
0.10
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 11 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-10-5 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=114/3-9-15(min. 0-1-8), 3=114/3-9-15(min. 0-1-8)
Max Horz1=86(LC 13)
Max Uplift1=-12(LC 16), 3=-42(LC 16)
MaxGrav1=129(LC 2), 3=144(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.06
0.04
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 7 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-7-5 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=70/2-6-15(min. 0-1-8), 3=70/2-6-15(min. 0-1-8)
Max Horz1=53(LC 13)
Max Uplift1=-7(LC 16), 3=-26(LC 16)
MaxGrav1=79(LC 2), 3=88(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.21
0.13
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 13 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-2-13 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=128/4-2-7(min. 0-1-8), 3=128/4-2-7(min. 0-1-8)
Max Horz1=96(LC 13)
Max Uplift1=-14(LC 16), 3=-47(LC 16)
MaxGrav1=144(LC 2), 3=161(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-5-12,Interior(1) 3-5-12 to 4-1-1zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Bearing at joint(s) 3 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.19
0.12
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 12 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-0-6 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=120/4-0-0(min. 0-1-8), 3=120/4-0-0(min. 0-1-8)
Max Horz1=90(LC 13)
Max Uplift1=-13(LC 16), 3=-44(LC 16)
MaxGrav1=136(LC 2), 3=152(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-5-12,Interior(1) 3-5-12 to 3-10-10zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.37
0.23
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-3-6 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=165/5-3-0(min. 0-1-8), 3=165/5-3-0(min. 0-1-8)
Max Horz1=124(LC 13)
Max Uplift1=-17(LC 16), 3=-61(LC 16)
MaxGrav1=186(LC 2), 3=208(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-5-12,Interior(1) 3-5-12 to 5-1-10zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.24
0.10
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 22 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=25/6-6-0(min. 0-1-8), 4=111/6-6-0(min. 0-1-8), 5=282/6-6-0(min. 0-1-8)
Max Horz1=157(LC 13)
Max Uplift1=-30(LC 14), 4=-37(LC 13), 5=-139(LC 16)
MaxGrav1=79(LC 13), 4=144(LC 29), 5=343(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-6=-254/238
WEBS 2-5=-280/198
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-5-12,Interior(1) 3-5-12 to 6-4-10zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 4 except(jt=lb)
5=139.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.36
0.11
0.07
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 27 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=82/7-9-0(min. 0-1-8), 4=107/7-9-0(min. 0-1-8), 5=318/7-9-0(min. 0-1-8)
Max Horz1=190(LC 13)
Max Uplift1=-11(LC 12), 4=-41(LC 13), 5=-157(LC 16)
MaxGrav1=128(LC 30), 4=141(LC 29), 5=386(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-6=-276/265, 2-6=-259/269
WEBS 2-5=-312/210
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-9-6,Interior(1) 3-9-6 to 7-7-10zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 4 except(jt=lb)
5=157.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.51
0.15
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 32 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=126/9-0-6(min. 0-1-8), 4=95/9-0-6(min. 0-1-8), 5=374/9-0-6(min. 0-1-8)
Max Horz1=223(LC 13)
Max Uplift1=-1(LC 12), 4=-44(LC 13), 5=-184(LC 16)
MaxGrav1=174(LC 30), 4=129(LC 29), 5=453(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-6=-303/272, 6-7=-279/299, 2-7=-276/303
WEBS 2-5=-363/247
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-5-12,Interior(1) 3-5-12 to 8-10-10zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 4 except(jt=lb)
5=184.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.68
0.12
0.10
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 38 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 10-3-0.
(lb)-Max Horz1=256(LC 13)
Max UpliftAll uplift 100 lb orless at joint(s) 1, 5 except 6=-159(LC 16), 7=-113(LC 16)
MaxGravAllreactions 250 lb orless at joint(s) 1, 5 except 6=391(LC 29), 7=277(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-374/368, 2-8=-297/259, 8-9=-273/286, 3-9=-270/290
WEBS 3-6=-311/213
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-5-12,Interior(1) 3-5-12 to 10-1-10zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 5 except(jt=lb)
6=159, 7=113.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.54
0.11
0.14
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 44 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 11-6-0.
(lb)-Max Horz1=289(LC 13)
Max UpliftAll uplift 100 lb orless at joint(s) 1, 5 except 6=-155(LC 16), 7=-133(LC 16)
MaxGravAllreactions 250 lb orless at joint(s) 1, 5 except 6=383(LC 29), 7=327(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-396/396, 2-8=-301/292, 3-8=-274/297
WEBS 3-6=-302/209, 2-7=-258/179
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-6-6,Interior(1) 3-6-6 to 11-4-10zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 5 except(jt=lb)
6=155, 7=133.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.42
0.19
0.19
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
-0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 50 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-5
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 12-9-0.
(lb)-Max Horz1=323(LC 13)
Max UpliftAll uplift 100 lb orless at joint(s) 1, 5 except 6=-144(LC 16), 7=-164(LC 16)
MaxGravAllreactions 250 lb orless at joint(s) 1, 5 except 6=351(LC 29), 7=403(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-8=-408/389, 2-8=-388/415, 2-3=-298/298
WEBS 3-6=-309/194, 2-7=-308/206
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-5-12,Interior(1) 3-5-12 to 12-7-10zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 5 except(jt=lb)
6=144, 7=164.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.32
0.21
0.21
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
6
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 56 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-6
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 14-0-6.
(lb)-Max Horz1=365(LC 16)
Max UpliftAll uplift 100 lb orless at joint(s) 6 except 7=-129(LC 16), 8=-200(LC 16)
MaxGravAllreactions 250 lb orless at joint(s) 6, 1 except 7=319(LC 29), 8=491(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-9=-366/280, 2-9=-346/313
WEBS 4-7=-259/186, 2-8=-356/238
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-5-12,Interior(1) 3-5-12 to 13-10-10zone;cantileverleft
exposed ; end verticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 6 except(jt=lb)
7=129, 8=200.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.19
0.11
0.30
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
7
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 64 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 6-7
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 15-3-6.
(lb)-Max Horz1=399(LC 16)
Max UpliftAll uplift 100 lb orless at joint(s) 7, 1 except 8=-149(LC 16), 9=-140(LC 16), 10=-132(LC 16)
MaxGravAllreactions 250 lb orless at joint(s) 7, 1 except 8=370(LC 29), 9=342(LC 29), 10=326(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-449/369, 2-3=-336/254, 3-4=-322/277
WEBS 5-8=-287/202, 4-9=-267/188
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-3-6,Interior(1) 3-3-6 to 15-1-10zone;cantileverleft exposed ;
endverticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)All plates are 1.5x4MT20 unless otherwiseindicated.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 7, 1 except(jt=lb)
8=149, 9=140, 10=132.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.20
0.12
0.35
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
7
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 72 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2
OTHERS 2x4SPFStud*Except*
ST3: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 6-7
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 16-6-6.
(lb)-Max Horz1=433(LC 16)
Max UpliftAll uplift 100 lb orless at joint(s) 7, 1 except 8=-151(LC 16), 9=-132(LC 16), 11=-160(LC 16)
MaxGravAllreactions 250 lb orless at joint(s) 7, 1 except 8=375(LC 29), 9=324(LC 29), 11=394(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-12=-470/361, 2-12=-445/386, 2-3=-333/230, 3-4=-319/270
WEBS 5-8=-289/204, 4-9=-254/182, 2-11=-289/198
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-5-12,Interior(1) 3-5-12 to 16-4-10zone;cantileverleft exposed
; end verticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)All plates are 1.5x4MT20 unless otherwiseindicated.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 7, 1 except(jt=lb)
8=151, 9=132, 11=160.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.29
0.19
0.18
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
7
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 79 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2
OTHERS 2x4SPFStud*Except*
ST3: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 6-7, 5-8
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 17-9-6.
(lb)-Max Horz1=467(LC 16)
Max UpliftAll uplift 100 lb orless at joint(s) 7 except 8=-155(LC 16), 9=-119(LC 16), 11=-195(LC 16)
MaxGravAllreactions 250 lb orless at joint(s) 7, 1 except 8=386(LC 22), 9=292(LC 29), 11=479(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-12=-493/376, 2-12=-473/408, 2-3=-328/221, 3-4=-304/261
WEBS 5-8=-296/207, 2-11=-345/234
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-5-12,Interior(1) 3-5-12 to 17-7-10zone;cantileverleft exposed
; end verticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)All plates are 1.5x4MT20 unless otherwiseindicated.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 7 except(jt=lb)
8=155, 9=119, 11=195.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.21
0.11
0.26
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
8
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 87 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2
OTHERS 2x4SPFStud*Except*
ST4: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 7-8, 6-9
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 19-0-6.
(lb)-Max Horz1=501(LC 16)
Max UpliftAll uplift 100 lb orless at joint(s) 8, 1 except 9=-150(LC 16), 10=-137(LC 16), 11=-143(LC 16),
13=-127(LC 16)
MaxGravAllreactions 250 lb orless at joint(s) 8 except 1=304(LC 16), 9=381(LC 22), 10=335(LC 29), 11=353(LC
29), 13=312(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-576/465, 2-14=-468/339, 3-14=-455/355, 3-4=-444/378, 4-5=-334/271
WEBS 6-9=-295/204, 5-10=-258/183, 4-11=-273/194
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-12 to 3-5-12,Interior(1) 3-5-12 to 18-10-10zone;cantileverleft
exposed ; end verticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)All plates are 1.5x4MT20 unless otherwiseindicated.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 8, 1 except(jt=lb)
9=150, 10=137, 11=143, 13=127.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
20-3-6
13-6-4
8.0012
PlateOffsets(X,Y)-- [21:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.11
0.03
0.16
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
13
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 132 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2
OTHERS 2x4SPFStud*Except*
ST9,ST8,ST7,ST6: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 12-13, 11-14, 10-15, 9-16
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 20-3-6.
(lb)-Max Horz1=535(LC 16)
Max UpliftAll uplift 100 lb orless at joint(s) 13, 1, 14, 15, 16, 17, 18, 19, 20,
21, 22
MaxGravAllreactions 250 lb orless at joint(s) 13, 14, 15, 16, 17, 18, 19, 20,
21, 22 except 1=329(LC 16)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-616/489, 2-3=-554/438, 3-4=-492/391, 4-5=-427/320, 5-6=-420/340, 6-7=-361/289,
7-8=-296/238
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-C Corner(3) 0-5-12 to 3-5-12,Exterior(2) 3-5-12 to 20-1-10zone;cantileverleft exposed ;
endverticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)All plates are 1.5x4MT20 unless otherwiseindicated.
6)Gablerequirescontinuous bottomchord bearing.
7)Gablestudsspaced at 2-0-0 oc.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 13, 1, 14, 15, 16,
17, 18, 19, 20, 21, 22.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S) Standard
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.01
0.03
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 6 lb FT= 20%
GRIP
185/148
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-5-6 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=62/2-4-14(min. 0-1-8), 3=62/2-4-14(min. 0-1-8)
Max Horz1=23(LC 13)
Max Uplift1=-7(LC 17), 3=-7(LC 17)
MaxGrav1=70(LC 2), 3=70(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.08
0.04
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 15 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-1-6 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=93/5-0-14(min. 0-1-8), 3=93/5-0-14(min. 0-1-8), 4=127/5-0-14(min. 0-1-8)
Max Horz1=-58(LC 12)
Max Uplift1=-29(LC 17), 3=-29(LC 17)
MaxGrav1=107(LC 2), 3=107(LC 2), 4=140(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.22
0.11
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 24 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=149/7-8-14(min. 0-1-8), 3=149/7-8-14(min. 0-1-8), 4=203/7-8-14(min. 0-1-8)
Max Horz1=-92(LC 12)
Max Uplift1=-47(LC 17), 3=-47(LC 17)
MaxGrav1=171(LC 2), 3=171(LC 2), 4=224(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-4 to 3-4-4,Interior(1) 3-4-4 to 3-10-11,Exterior(2) 3-10-11 to 6-10-11
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.44
0.21
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 33 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=205/10-4-14(min. 0-1-8), 3=205/10-4-14(min. 0-1-8), 4=280/10-4-14(min. 0-1-8)
Max Horz1=-127(LC 12)
Max Uplift1=-65(LC 17), 3=-65(LC 17)
MaxGrav1=236(LC 2), 3=236(LC 2), 4=308(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-4 to 3-4-4,Interior(1) 3-4-4 to 5-2-11,Exterior(2) 5-2-11 to 8-2-11zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.15
0.11
0.11
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 47 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 13-0-14.
(lb)-Max Horz1=-162(LC 12)
Max UpliftAll uplift 100 lb orless at joint(s) 1, 5 except 8=-227(LC 16), 6=-227(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 1, 5, 7 except 8=349(LC 29), 6=348(LC 30)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 2-8=-322/268, 4-6=-322/268
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-4 to 3-4-4,Interior(1) 3-4-4 to 6-6-11,Exterior(2) 6-6-11 to 9-6-11zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 5 except(jt=lb)
8=227, 6=227.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
0-0-4
12.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.18
0.10
0.17
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 59 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud*Except*
ST2: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 15-8-14.
(lb)-Max Horz1=197(LC 13)
Max UpliftAll uplift 100 lb orless at joint(s) 1, 5 except 8=-264(LC 16), 6=-263(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 1, 5, 7 except 8=411(LC 29), 6=411(LC 30)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 2-8=-359/296, 4-6=-359/296
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-4 to 3-4-4,Interior(1) 3-4-4 to 7-10-11,Exterior(2) 7-10-11 to 10-10-11
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 5 except(jt=lb)
8=264, 6=263.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
0-0-4
9-2-11
0-0-4
12.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.26
0.17
0.20
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.01
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 71 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud*Except*
ST2: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-7
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 18-4-14.
(lb)-Max Horz1=-232(LC 12)
Max UpliftAll uplift 100 lb orless at joint(s) 1 except 9=-317(LC 16), 6=-317(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 1, 5, 7 except 9=501(LC 29), 6=500(LC 30)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 2-9=-423/345, 4-6=-423/345
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-4 to 3-4-4,Interior(1) 3-4-4 to 9-2-11,Exterior(2) 9-2-11 to 12-2-11
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)Gablerequirescontinuous bottomchord bearing.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1 except(jt=lb)
9=317, 6=317.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
10-6-11
0-0-4
10-6-11
0-0-4
12.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.17
0.10
0.28
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.01
(loc)
-
-
7
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 88 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud*Except*
ST3: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-10
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 21-0-14.
(lb)-Max Horz1=267(LC 13)
Max UpliftAll uplift 100 lb orless at joint(s) 7 except 1=-106(LC 14), 11=-257(LC 16), 13=-196(LC 16),
9=-256(LC 17), 8=-196(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 1, 7 except 10=275(LC 32), 11=402(LC 29), 13=314(LC 29),
9=401(LC 30), 8=315(LC 30)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-338/220, 6-7=-294/186
WEBS 3-11=-364/307, 2-13=-284/233, 5-9=-364/306, 6-8=-284/233
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-4 to 3-4-4,Interior(1) 3-4-4 to 10-6-11,Exterior(2) 10-6-11 to 13-6-11
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)All plates are 1.5x4MT20 unless otherwiseindicated.
6)Gablerequirescontinuous bottomchord bearing.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 7 except(jt=lb)
1=106, 11=257, 13=196, 9=256, 8=196.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
23-9-6
23-9-2
11-10-11
11-10-11
23-9-6
11-10-11
0-0-4
11-10-11
0-0-4
12.0012
PlateOffsets(X,Y)-- [13:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.17
0.11
0.38
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.01
(loc)
-
-
9
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 104 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4 HF/SPF No.2 *Except*
ST1: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-12
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 23-8-14.
(lb)-Max Horz1=301(LC 13)
Max UpliftAll uplift 100 lb orless at joint(s) 1, 9 except 13=-252(LC 16), 14=-240(LC 16), 11=-247(LC 17),
10=-239(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 1, 9 except 12=298(LC 32), 13=392(LC 29), 14=381(LC 29),
11=385(LC 30), 10=383(LC 30)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-15=-355/217, 2-15=-327/245, 8-20=-271/187, 9-20=-299/159
BOT CHORD 1-14=-168/270, 13-14=-168/270, 12-13=-162/267, 11-12=-162/267, 10-11=-162/267,
9-10=-162/267
WEBS 4-13=-360/305, 2-14=-332/269, 6-11=-354/299, 8-10=-332/269
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-4 to 3-4-4,Interior(1) 3-4-4 to 11-10-11,Exterior(2) 11-10-11 to
14-10-11zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS for
reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)All plates are 1.5x4MT20 unless otherwiseindicated.
6)Gablerequirescontinuous bottomchord bearing.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 1, 9 except(jt=lb)
13=252, 14=240, 11=247, 10=239.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.32
0.17
0.20
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
6
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 67 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2
OTHERS 2x4 HF/SPF No.2 *Except*
ST1: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-6, 4-7
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 13-2-7.
(lb)-Max Horz1=519(LC 16)
Max UpliftAll uplift 100 lb orless at joint(s) 6, 1 except 7=-226(LC 16), 8=-296(LC 16)
MaxGravAllreactions 250 lb orless at joint(s) 6 except 1=404(LC 16), 7=364(LC 29), 8=472(LC 29)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-9=-616/482, 2-9=-591/518, 2-3=-348/237, 3-4=-317/288
WEBS 4-7=-349/288, 2-8=-406/321
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-4 to 3-4-4,Interior(1) 3-4-4 to 13-0-15zone;cantileverleft exposed ;
endverticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)Gablerequirescontinuous bottomchord bearing.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 6, 1 except(jt=lb)
7=226, 8=296.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
2-4-8
2-4-8
6-6-9
4-2-1
10-10-7
4-3-13
15-4-0
4-5-9
1-2-15
2-1-3
2-2-13
2-1-3
5.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.31
0.51
0.62
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.14
0.02
(loc)
8-9
8-9
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 62 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-1-11 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)7=608/0-6-0(min. 0-1-8), 11=642/0-6-0(min. 0-1-8)
Max Horz11=82(LC 9)
Max Uplift7=-178(LC 9), 11=-204(LC 8)
MaxGrav7=778(LC 31), 11=702(LC 31)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-803/216, 3-12=-1621/388, 4-12=-1624/388, 4-13=-1389/325, 13-14=-1389/325,
5-14=-1389/325, 5-15=-1389/325, 15-16=-1389/325, 6-16=-1389/325, 6-7=-728/199,
2-11=-689/208
BOT CHORD 10-17=-248/764, 9-17=-248/764, 9-18=-408/1621, 18-19=-408/1621, 8-19=-408/1621
WEBS 3-10=-279/129, 3-9=-190/939, 4-9=-299/131, 4-8=-252/81, 5-8=-379/157,
6-8=-333/1448, 2-10=-193/813
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate
grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
7=178, 11=204.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 63 lb down and 107 lb up at
2-4-8, 21 lb down and 40 lb up at 4-5-4, 21 lb down and 40 lb up at 6-5-4, 21 lb down and 40 lb up at 8-5-4, 21 lb down and 40 lb
up at 10-5-4, and 21 lb down and 40 lb up at 12-5-4, and 21 lb down and 41 lb up at 14-5-4 on top chord, and 12 lb down and 11
lb up at 2-4-8, 7 lb down and 4 lb up at 4-5-4, 7 lb down and 4 lb up at 6-5-4, 7 lb down and 4 lb up at 8-5-4, 7 lb down and 4 lb
up at 10-5-4, and 7 lb down and 4 lb up at 12-5-4, and 9 lb down and 2 lb up at 14-5-4 on bottomchord.The design/selection of
suchconnection device(s)is the responsibility of others.
Continued 11)In the LOAD on page CASE(2 S)section,loads applied to the face of the truss are noted as front(F) or back(B).
3x4
2x4
1.5x4
3x4
3x8
4x12
3x4 4x4
4x4
6x8
3x5
3x4
1-4-12
1-4-12
2-6-0
1-1-4
4-4-8
1-10-8
8-7-4
4-2-12
12-10-0
4-2-12
15-4-0
2-6-0
-0-10-12
0-10-12
1-4-12
1-4-12
2-6-0
1-1-4
4-4-8
1-10-8
8-7-4
4-2-12
12-10-0
4-2-12
15-4-0
2-6-0
1-2-15
2-11-3
3-0-13
2-11-3
1-0-0
5.0012
PlateOffsets(X,Y)-- [11:0-2-4,0-2-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.28
0.49
0.46
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.15
0.10
(loc)
12
12-13
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 71 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2 *Except*
B2,B4: 2x4SPFStud
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-0-3 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)9=600/0-6-0(min. 0-1-8), 17=626/0-6-0(min. 0-1-8)
Max Horz17=118(LC 13)
Max Uplift9=-128(LC 13), 17=-117(LC 12)
MaxGrav9=750(LC 35), 17=666(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-479/112, 3-4=-1349/431, 4-5=-1321/305, 5-18=-1709/296, 6-18=-1712/296,
6-19=-937/164, 7-19=-937/164, 7-8=-870/154, 8-9=-710/151, 2-17=-631/193
BOT CHORD 13-14=-522/1290, 12-13=-355/1233, 11-12=-351/1709, 7-11=-300/106
WEBS 3-16=-725/278, 14-16=-274/499, 3-14=-305/891, 5-12=-89/513, 6-11=-824/150,
8-11=-214/1075, 2-16=-76/503
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-12 to 2-4-4,Interior(1) 2-4-4 to 4-4-8,Exterior(2) 4-4-8 to 8-7-4zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
9=128, 17=117.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
3x8
6x8
4x4
1.5x4
3x4
3x8
4x12
4x4
3x5
3x4
1-4-12
1-4-12
2-6-0
1-1-4
6-4-8
3-10-8
12-10-0
6-5-8
15-4-0
2-6-0
-0-10-12
0-10-12
1-4-12
1-4-12
2-6-0
1-1-4
6-4-8
3-10-8
12-10-0
6-5-8
15-4-0
2-6-0
1-2-15
3-9-3
3-10-13
3-9-3
1-0-0
5.0012
PlateOffsets(X,Y)-- [10:0-2-4,0-2-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.63
0.46
0.47
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.19
0.08
(loc)
10-11
10-11
8
l/defl
>999
>975
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 73 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2 *Except*
B2,B4: 2x4SPFStud
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-9-8 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)8=593/0-6-0(min. 0-1-8), 15=613/0-6-0(min. 0-1-8)
Max Horz15=155(LC 13)
Max Uplift8=-126(LC 13), 15=-101(LC 12)
MaxGrav8=712(LC 35), 15=733(LC 36)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-496/95, 3-4=-1369/470, 4-16=-1042/219, 5-16=-1003/234, 5-17=-684/155,
17-18=-684/154, 18-19=-685/154, 6-19=-687/154, 6-7=-609/136, 7-8=-673/160,
2-15=-697/185
BOT CHORD 11-12=-648/1397, 10-11=-321/947, 6-10=-514/181
WEBS 3-14=-707/288, 12-14=-303/493, 3-12=-385/944, 4-11=-579/337, 5-11=0/301,
5-10=-446/137, 7-10=-216/916, 2-14=-66/501
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-12 to 2-4-4,Interior(1) 2-4-4 to 6-4-8,Exterior(2) 6-4-8 to 10-7-7zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
8=126, 15=101.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
5x8
6x8
2x4
1.5x4
3x5
3x8
4x12
4x4
3x4
3x4
1-4-12
1-4-12
2-6-0
1-1-4
8-4-8
5-10-8
12-10-0
4-5-8
15-4-0
2-6-0
-0-10-12
0-10-12
1-4-12
1-4-12
2-6-0
1-1-4
8-4-8
5-10-8
12-10-0
4-5-8
15-4-0
2-6-0
1-2-15
4-7-3
4-8-13
4-7-3
1-0-0
5.0012
PlateOffsets(X,Y)-- [10:0-2-12,0-2-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.52
0.57
0.78
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.06
-0.16
0.10
(loc)
11-12
11-12
8
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 77 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2 *Except*
B2,B4: 2x4SPFStud
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-3-4 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except:
6-0-0 oc bracing: 14-15
6-6-5 oc bracing: 11-12.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)8=583/0-6-0(min. 0-1-8), 15=603/0-6-0(min. 0-1-8)
Max Horz15=191(LC 13)
Max Uplift8=-122(LC 13), 15=-112(LC 16)
MaxGrav8=659(LC 35), 15=790(LC 36)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-539/86, 3-4=-1584/488, 4-16=-876/150, 16-17=-774/157, 5-17=-764/169,
5-18=-411/129, 18-19=-413/128, 6-19=-413/128, 6-7=-390/122, 7-8=-625/189,
2-15=-753/178
BOT CHORD 14-15=-256/201, 11-12=-758/1760, 10-11=-288/707, 6-10=-357/126
WEBS 3-14=-749/276, 12-14=-312/526, 3-12=-450/1173, 4-11=-1057/475, 5-11=0/318,
5-10=-499/151, 7-10=-209/697, 2-14=-53/533
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-12 to 2-4-4,Interior(1) 2-4-4 to 8-4-8,Exterior(2) 8-4-8 to 12-7-7zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
8=122, 15=112.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.73
0.99
0.14
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.03
-0.07
0.00
(loc)
4-5
4-5
4
l/defl
>999
>648
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 22 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x6SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-10-8 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 4-9-5 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)6=789/Mechanical, 4=795/Mechanical
Max Horz6=9(LC 52)
Max Uplift6=-282(LC 8), 4=-296(LC 8)
MaxGrav6=800(LC 30), 4=833(LC 30)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-6=-335/111
WEBS 2-5=-168/335
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone; porchleft and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7) Refer to girder(s) for truss to trussconnections.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
6=282, 4=296.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 1302 lb down and 484 lb up at
1-11-4 on bottomchord.The design/selection of suchconnection device(s)is the responsibility of others.
11)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S) Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-51, 2-3=-61, 4-6=-20
Concentrated Loads(lb)
Vert: 7=-1302(F)
2-10-12
9-10-0
3-2-4
-0-10-12
0-10-12
2-7-8
2-7-8
3-9-0
1-1-8
6-7-12
2-10-12
9-10-0
3-2-4
1-2-15
2-8-1
2-9-11
2-8-1
5.0012
PlateOffsets(X,Y)-- [8:0-1-8,Edge], [9:0-3-0,0-4-4], [10:0-3-8,0-2-0], [11:Edge,0-3-8], [11:0-0-0,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MP
0.33
0.64
0.99
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.04
-0.08
0.01
(loc)
8-9
8-9
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 104 lb FT= 20%
GRIP
185/144
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x6SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size)7=3674/0-6-0(min. 0-2-15), 11=2971/0-4-0(min. 0-2-7)
Max Horz11=65(LC 9)
Max Uplift7=-1488(LC 9), 11=-1291(LC 8)
MaxGrav7=3739(LC 31), 11=3075(LC 32)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-12=-3761/1612, 3-12=-3705/1614, 3-4=-3889/1681, 4-13=-3677/1499, 5-13=-3681/1499,
5-14=-3677/1497, 6-14=-3677/1497, 6-7=-2904/1169, 2-11=-2922/1228
BOT CHORD 9-10=-1517/3422, 9-15=-1562/3605, 8-15=-1562/3605
WEBS 3-10=-437/123, 3-9=-230/625, 4-9=-513/1173, 5-8=-360/165, 6-8=-1876/4608,
2-10=-1548/3649
NOTES-
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-7-0 oc.
Bottomchordsconnected as follows: 2x6- 2 rowsstaggered at 0-5-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3) Unbalancedroofliveloads have been considered for this design.
4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft exposed ; end verticalleft exposed; porchleft exposed; Lumber DOL=1.60 plate
grip DOL=1.60
5)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
6) Unbalancedsnowloads have been considered for this design.
7)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
8)Provide adequate drainage to preventwater ponding.
9)All plates areMT20 plates unless otherwiseindicated.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
7=1488, 11=1291.
12)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
Continued on page 2
4-7-5
13-11-12
4-7-5
18-7-1
4-7-5
23-2-7
4-7-5
27-8-0
4-5-9
30-2-0
2-6-0
4-9-1
4-9-1
9-4-7
4-7-5
13-11-12
4-7-5
18-7-1
4-7-5
23-2-7
4-7-5
27-8-0
4-5-9
30-2-0
2-6-0
31-0-12
0-10-12
2-1-13
2-3-7
1-2-15
2-1-13
5.0012
PlateOffsets(X,Y)-- [8:0-4-0,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.27
0.27
0.84
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.28
-0.47
0.03
(loc)
14-16
14-16
10
l/defl
>999
>773
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 415 lb FT= 20%
GRIP
197/144
244/190
LUMBER-
TOP CHORD2x8SP 2400F 2.0E*Except*
T3: 2x6SP 2400F 2.0E
BOT CHORD2x6SP 2400F 2.0E
WEBS 2x4SPFStud
SLIDER Right 2x6SP 2400F 2.0E 1-6-0
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size)19=1322/Mechanical, 10=1931/0-4-0(min. 0-1-8)
Max Horz19=-50(LC 13)
Max Uplift19=-766(LC 8), 10=-1012(LC 9)
MaxGrav19=1639(LC 31), 10=2129(LC 31)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-19=-1543/717, 1-24=-3824/1807, 24-25=-3824/1807, 2-25=-3824/1807,
2-26=-6331/3000, 26-27=-6331/3000, 3-27=-6331/3000, 3-4=-7566/3593,
4-28=-7566/3593, 28-29=-7566/3593, 5-29=-7566/3593, 5-30=-7566/3593,
30-31=-7566/3593, 31-32=-7566/3593, 6-32=-7566/3593, 6-33=-7493/3524,
33-34=-7493/3524, 7-34=-7493/3524, 7-35=-6211/2879, 35-36=-6211/2879,
8-36=-6206/2879, 8-9=-3397/1575, 9-10=-925/448
BOT CHORD 18-39=-1777/3824, 39-40=-1777/3824, 17-40=-1777/3824, 17-41=-2971/6331,
41-42=-2971/6331, 16-42=-2971/6331, 16-43=-3494/7493, 15-43=-3494/7493,
15-44=-3494/7493, 14-44=-3494/7493, 14-45=-2847/6205, 45-46=-2847/6205,
13-46=-2847/6205, 13-47=-1331/2910, 47-48=-1331/2910, 48-49=-1331/2910,
12-49=-1331/2910, 10-12=-1343/2946
WEBS 1-18=-1838/3892, 2-18=-1235/565, 2-17=-1265/2657, 3-17=-793/361, 3-16=-628/1309,
5-16=-343/165, 6-14=-420/190, 7-14=-687/1365, 7-13=-956/446, 8-13=-1627/3537,
8-12=-212/538
NOTES-
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x8- 2 rowsstaggered at 0-9-0 oc, 2x6- 2 rowsstaggered at 0-9-0 oc.
Bottomchordsconnected as follows: 2x6- 2 rowsstaggered at 0-9-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3) Unbalancedroofliveloads have been considered for this design.
4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverright exposed ; end verticalright exposed; porchleft and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
5)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
Continued on page 2
4-11-2
15-6-9
4-11-2
20-5-10
4-11-2
25-6-8
5-0-14
26-4-8
0-10-0
0-7-8
0-7-8
5-8-6
5-0-14
10-7-7
4-11-2
15-6-9
4-11-2
20-5-10
4-11-2
25-6-8
5-0-14
26-4-8
0-10-0
2-10-15
3-0-7
3-2-1
2-9-14
3-0-7
5.0012
PlateOffsets(X,Y)-- [1:Edge,0-3-0], [8:0-7-4,0-3-0], [12:0-3-8,0-2-0], [16:0-3-8,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.40
0.86
0.99
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.21
-0.41
0.09
(loc)
13-15
13-15
10
l/defl
>999
>758
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 137 lb FT= 20%
GRIP
185/144
185/144
LUMBER-
TOP CHORD2x8SP 2400F 2.0E*Except*
T2,T3: 2x6SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-10-10 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 4-3-5 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)18=1049/Mechanical, 10=1047/Mechanical
Max Horz18=-6(LC 17)
Max Uplift18=-467(LC 13), 10=-464(LC 13)
MaxGrav18=1333(LC 37), 10=1322(LC 37)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-19=-2292/1242, 3-19=-2292/1242, 3-4=-3248/1740, 4-5=-3248/1740, 5-6=-3258/1747,
6-7=-3258/1747, 7-20=-2348/1276, 8-20=-2348/1276, 8-9=-331/208, 1-18=-1089/709,
9-10=-1257/776
BOT CHORD 16-17=-144/259, 15-16=-1231/2292, 14-15=-1736/3258, 13-14=-1736/3258,
12-13=-1265/2348, 11-12=-213/375
WEBS 2-17=-1156/544, 2-16=-1227/2296, 3-16=-957/402, 3-15=-583/1087, 4-15=-415/142,
5-13=-396/135, 7-13=-551/1034, 7-12=-931/387, 8-12=-1187/2229, 8-11=-1166/561,
1-17=-599/971, 9-11=-705/1192
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 4-10-7,Interior(1) 4-10-7 to 25-6-8,Exterior(2) 25-6-8 to 26-2-12
zone; porchleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip
DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)All plates areMT20 plates unless otherwiseindicated.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8) Refer to girder(s) for truss to trussconnections.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
18=467, 10=464.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S) Standard
4x6
7x14MT18H
2-7-8
2-7-8
7-9-6
5-1-14
13-1-0
5-3-10
18-4-10
5-3-10
23-6-8
5-1-14
26-5-4
2-10-12
30-2-0
3-8-12
2-7-8
2-7-8
7-9-6
5-1-14
13-1-0
5-3-10
18-4-10
5-3-10
23-6-8
5-1-14
26-5-4
2-10-12
30-2-0
3-8-12
31-0-12
0-10-12
2-10-15
3-10-7
4-0-1
1-2-15
3-10-7
5.0012
PlateOffsets(X,Y)-- [11:0-0-0,0-1-12], [11:Edge,0-3-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.79
0.74
0.87
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.24
-0.47
0.08
(loc)
14-16
14-16
11
l/defl
>999
>760
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 153 lb FT= 20%
GRIP
185/144
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x6SPF No.2
WEBS 2x4SPFStud*Except*
W8: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-4-2 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-8-15 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)19=1273/Mechanical, 11=1918/0-4-0(min. 0-3-2)
Max Horz19=-87(LC 13)
Max Uplift19=-542(LC 8), 11=-757(LC 9)
MaxGrav19=1485(LC 34), 11=1981(LC 34)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-1061/393, 2-3=-2686/978, 3-4=-3493/1270, 4-5=-3493/1270, 5-6=-3493/1270,
6-20=-3507/1288, 7-20=-3504/1288, 7-8=-2840/1063, 8-9=-2926/1080, 1-19=-1475/538,
9-11=-1862/713
BOT CHORD 17-18=-309/1026, 16-17=-898/2683, 15-16=-1208/3504, 14-15=-1208/3504,
13-14=-918/2635, 12-13=-961/2669
WEBS 2-18=-981/346, 2-17=-714/2012, 3-17=-1039/367, 3-16=-352/970, 4-16=-430/147,
6-14=-505/232, 7-14=-477/1055, 7-13=-199/431, 8-13=-401/476, 8-12=-417/327,
1-18=-515/1455, 9-12=-908/2541
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverright exposed ; end verticalright exposed; porchleft and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0 Rainsurcharge applied to all
exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9) Refer to girder(s) for truss to trussconnections.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
19=542, 11=757.
11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
Continued on page 2
4x6
3x6
4x6
3x8
4-7-8
4-7-8
10-2-9
5-7-1
15-11-7
5-8-13
21-6-8
5-7-1
25-9-13
4-3-5
30-2-0
4-4-3
4-7-8
4-7-8
10-2-9
5-7-1
15-11-7
5-8-13
21-6-8
5-7-1
25-9-13
4-3-5
30-2-0
4-4-3
31-0-12
0-10-12
2-10-15
4-8-7
4-10-1
1-2-15
4-8-7
5.0012
PlateOffsets(X,Y)-- [15:0-3-8,0-1-8], [16:0-3-8,0-1-8], [17:0-4-8,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.57
0.61
0.73
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.17
-0.32
0.08
(loc)
13-15
13-15
10
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 137 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-11-1 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 5-2-6 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)10=1185/0-4-0(min. 0-2-1), 17=1153/Mechanical
Max Horz17=-101(LC 17)
Max Uplift10=-483(LC 13), 17=-480(LC 12)
MaxGrav10=1259(LC 2), 17=1263(LC 38)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-18=-1272/798, 2-18=-1228/809, 2-19=-2185/1333, 19-20=-2187/1332, 3-20=-2189/1332,
3-4=-2393/1471, 4-5=-2393/1471, 5-21=-2396/1472, 21-22=-2395/1472,
6-22=-2394/1473, 6-7=-1943/1280, 7-23=-1717/1212, 23-24=-1723/1201,
8-24=-1768/1194, 1-17=-1226/787, 8-10=-1208/801
BOT CHORD 15-16=-644/1182, 14-15=-1174/2187, 13-14=-1174/2187, 12-13=-1038/1788,
11-12=-1036/1585
WEBS 2-16=-600/265, 2-15=-702/1286, 3-15=-688/271, 3-13=-182/280, 5-13=-529/181,
6-13=-358/774, 7-12=-122/254, 7-11=-290/125, 1-16=-803/1349, 8-11=-1008/1527
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 4-7-8,Exterior(2) 4-7-8 to 25-9-13,
Interior(1) 25-9-13 to 31-0-12zone;cantileverright exposed ; end verticalright exposed; porchleft and right exposed;C-C for
members and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8) Refer to girder(s) for truss to trussconnections.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
10=483, 17=480.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S) Standard
1 2
3
4
5 6 7 8
9
10
11 12 13 14
15
16
17
18
19
37
36
35 34 33
32
31
30 29 28 27 26
25 24
23 22 21 20
46
47
48 4950
51
52 53 54
55
56
3x4
6x8
8x8 8x8
6x6
6x6
8x8 3x5
3x6
6x8
4x8
4x4
4x4
4x4
5x6
5x12 8x10
4x6
4x6
3x6
4x6
4x6
4x6
4x8
4x4
4x6 4x6
4x4
4x6
4x4
3x6 5x10
4x4
6x8
2-6-0
2-6-0
5-10-0
3-4-0
9-2-0
3-4-0
12-2-0
3-0-0
12-10-0
0-8-0
15-2-0
2-4-0
17-2-3
2-0-3
19-2-6
2-0-3
22-3-3
3-0-13
25-4-0
3-0-13
29-8-11
4-4-11
34-1-5
4-4-11
38-6-0
4-4-11
41-10-13
3-4-13
45-3-11
3-4-13
49-0-0
3-8-5
-0-10-12
0-10-12
2-6-0
2-6-0
5-10-0
3-4-0
9-2-0
3-4-0
12-2-0
3-0-0
15-2-0
3-0-0
17-2-3
2-0-3
19-2-6
2-0-3
22-3-3
3-0-13
25-4-0
3-0-13
29-8-11
4-4-11
34-1-5
4-4-11
38-6-0
4-4-11
41-10-13
3-4-13
45-3-11
3-4-13
49-0-0
3-8-5
49-10-12
0-10-12
1-2-15
4-11-2
7-5-13
7-7-7
1-2-15
2-0-0
5.0012
6.0012
PlateOffsets(X,Y)-- [5:0-4-0,0-3-4], [9:0-2-12,0-3-4], [18:0-5-12,0-0-1], [31:0-4-0,0-5-4], [36:0-1-6,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.11
0.89
0.91
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.27
-0.65
0.20
(loc)
29
29
18
l/defl
>999
>895
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 794 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x6SP 2400F 2.0E*Except*
T2: 2x8SP 2400F 2.0E
BOT CHORD2x8SP 2400F 2.0E*Except*
B1: 2x4SP 2400F 2.0E,B2: 2x6SP 2400F 2.0E
B3,F1,F4: 2x4SPFStud
WEBS 2x4SPFStud*Except*
W1,W3: 2x6SP 2400F 2.0E,W11: 2x4 HF/SPF No.2
F2: 2x6SPF No.2
SLIDER Right 2x6SP 2400F 2.0E 1-6-0
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size)37=1902/0-6-0(min. 0-1-8), 18=1886/0-6-0(min. 0-1-8)
Max Horz37=149(LC 16)
Max Uplift37=-324(LC 16), 18=-251(LC 12)
MaxGrav37=2019(LC 2), 18=2004(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-37=-2083/450, 2-3=-4682/920, 3-46=-4692/887, 46-47=-4662/891, 4-47=-4634/900,
4-5=-4509/854, 5-48=-5287/969, 6-48=-5297/968, 6-49=-8564/1501, 49-50=-8564/1501,
7-50=-8564/1501, 7-8=-8622/1510, 8-9=-9405/1641, 9-51=-6910/1235, 10-51=-6895/1245,
10-11=-5421/1005, 11-52=-4836/892, 12-52=-4838/892, 12-53=-4836/891,
53-54=-4836/891, 13-54=-4836/891, 13-14=-4300/803, 14-15=-3587/678,
15-55=-3478/647, 55-56=-3515/637, 16-56=-3516/632, 16-17=-2983/539,
17-18=-1867/322
BOT CHORD 36-37=-238/387, 35-36=-893/4144, 34-35=-846/4352, 33-34=-737/4182, 32-33=-119/712,
30-31=-1563/9386, 29-30=-1544/9221, 28-29=-1540/9208, 27-28=-1038/6340,
26-27=-761/4986, 25-26=-761/4986, 24-25=-617/4298, 23-24=-617/4298,
22-23=-465/3323, 21-22=-504/3246, 20-21=-413/2634, 18-20=-413/2634
WEBS 2-36=-713/3807, 3-35=-1/308, 4-34=-448/145, 5-34=-59/388, 5-33=-256/1712,
6-33=-3101/537, 31-33=-827/4894, 6-31=-688/4219, 8-31=-1122/186, 9-30=-113/360,
9-28=-3668/642, 10-28=-363/2346, 10-27=-2138/438, 11-27=-334/1939, 11-25=-383/166,
12-25=-410/135, 13-25=-155/821, 13-23=-1032/236, 14-23=-239/1478, 14-22=-41/264,
15-21=-260/81, 16-21=-108/816, 16-20=-493/125
NOTES-
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x6- 2 rowsstaggered at 0-9-0 oc, 2x8- 2 rowsstaggered at 0-9-0 oc.
Bottomchordsconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x6- 2 rowsstaggered at 0-9-0 oc, 2x8- 2 rowsstaggered at 0-9-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x6- 2 rowsstaggered at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3) Unbalancedroofliveloads have been considered for this design.
Continued on page 2
5
6 7 8
9
10
11 12 13
14
15
16
17
35
34
33 32 31
30
29
28 27 26 25 24
23 22
21 20 19
45
46 47 48
49 50
51
52 54 53
55 56
57
58
59
60
3x4
6x6
6x6 6x8
6x6
6x6
8x8
2x4
3x4
2x4
3x4
4x6
4x8
4x12
6x10
2x4
4x6
2x4
4x8
4x6 2x4 4x12
2x4
2x4
2x4
2x4
2x4
2-6-0
2-6-0
5-4-11
2-10-11
8-3-5
2-10-11
11-2-0
2-10-11
12-10-0
1-8-0
15-2-0
2-4-0
18-2-3
3-0-3
21-2-6
3-0-3
24-3-3
3-0-13
27-4-0
3-0-13
31-11-0
4-7-0
36-6-0
4-7-0
40-6-13
4-0-13
44-7-11
4-0-13
49-0-0
4-4-5
-0-10-12
0-10-12
2-6-0
2-6-0
5-4-11
2-10-11
8-3-5
2-10-11
11-2-0
2-10-11
15-2-0
4-0-0
18-2-3
3-0-3
21-2-6
3-0-3
24-3-3
3-0-13
27-4-0
3-0-13
31-11-0
4-7-0
36-6-0
4-7-0
40-6-13
4-0-13
44-7-11
4-0-13
49-0-0
4-4-5
49-10-12
0-10-12
1-2-15
5-9-2
8-3-13
8-5-7
1-2-15
2-0-0
5.0012
6.0012
PlateOffsets(X,Y)-- [2:0-2-8,0-2-12], [9:0-2-12,0-3-0], [17:0-7-12,0-0-4], [29:0-4-8,0-3-4], [34:0-1-6,0-1-0], [35:0-1-9,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.23
0.56
0.89
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.21
-0.53
0.19
(loc)
27
27
17
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 745 lb FT= 20%
GRIP
197/144
LUMBER-
TOP CHORD2x6SP 2400F 2.0E
BOT CHORD2x6SP 2400F 2.0E*Except*
B1: 2x4SP 2400F 2.0E,B3,F1,F4: 2x4SPFStud
WEBS 2x4SPFStud*Except*
W3,F2: 2x6SPF No.2
SLIDER Right 2x6SP 2400F 2.0E 1-6-0
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size)35=1882/0-6-0(min. 0-1-8), 17=1867/0-6-0(min. 0-1-8)
Max Horz35=163(LC 16)
Max Uplift35=-336(LC 16), 17=-223(LC 12)
MaxGrav35=2088(LC 44), 17=2096(LC 44)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-35=-2064/431, 2-3=-4834/951, 3-45=-4819/880, 4-45=-4790/891, 4-46=-4469/840,
46-47=-4432/843, 5-47=-4426/850, 5-6=-4159/809, 6-48=-5971/1127, 7-48=-5973/1127,
7-49=-6011/1132, 8-49=-6011/1132, 8-50=-6719/1246, 9-50=-6717/1246,
9-51=-5525/1042, 10-51=-5503/1050, 10-11=-4373/873, 11-52=-3713/762,
52-53=-3713/762, 53-54=-3714/761, 12-54=-3714/761, 12-55=-3714/761,
13-55=-3714/762, 13-56=-3371/669, 14-56=-3382/652, 14-57=-3417/645,
15-57=-3492/633, 15-58=-3086/556, 58-59=-3175/556, 16-59=-3196/542, 16-17=-940/151
BOT CHORD 33-34=-982/4308, 32-33=-907/4486, 31-32=-768/4091, 30-31=-87/509, 7-29=-303/105,
28-29=-1142/6716, 27-28=-1171/6875, 26-27=-1169/6874, 25-26=-831/5050,
24-25=-614/4010, 23-24=-614/4010, 22-23=-431/3087, 21-22=-431/3087,
20-21=-488/3223, 19-20=-415/2778, 17-19=-415/2778
WEBS 2-34=-796/4153, 3-33=-1/278, 4-32=-586/169, 5-32=-68/385, 5-31=-503/145,
6-31=-627/125, 29-31=-608/3468, 6-29=-465/2891, 8-29=-1020/163, 8-28=-20/424,
9-28=-344/76, 9-26=-2743/501, 10-26=-330/2048, 10-25=-1887/397, 11-25=-305/1751,
11-23=-567/181, 12-23=-471/154, 13-23=-203/1139, 13-21=-56/357, 14-21=-380/145,
15-20=-89/652, 15-19=-285/104
NOTES-
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x6- 2 rowsstaggered at 0-9-0 oc.
Bottomchordsconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x6- 2 rowsstaggered at 0-9-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x6- 2 rowsstaggered at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3) Unbalancedroofliveloads have been considered for this design.
Continued on page 2
12
3
4
5
6 7 8
9
10
11 12
13
14
15
16
17
18
34
33
32 31
30 29
28
27 26 2524
23 22
21 20 19
43
44
45
46
47 4849 50
51
52 53 54 55
56
57
3x4
6x6
6x6 6x8
5x6
6x6
4x6
8x8
2x4
3x4
2x4
5x6
4x6
4x8
5x10
2x4
6x8
4x6
4x8
4x6 2x4 5x12
2x4
2x4 2x4
2x4
2-6-0
2-6-0
6-0-11
3-6-11
9-7-5
3-6-11
12-10-0
3-2-11
13-2-0
0-4-0
15-2-0
2-0-0
19-2-3
4-0-3
23-2-6
4-0-3
26-3-3
3-0-13
29-4-0
3-0-13
34-6-0
5-2-0
39-2-13
4-8-13
43-11-11
4-8-13
49-0-0
5-0-5
-0-10-12
0-10-12
2-6-0
2-6-0
6-0-11
3-6-11
9-7-5
3-6-11
13-2-0
3-6-11
15-2-0
2-0-0
19-2-3
4-0-3
23-2-6
4-0-3
26-3-3
3-0-13
29-4-0
3-0-13
34-6-0
5-2-0
39-2-13
4-8-13
43-11-11
4-8-13
49-0-0
5-0-5
49-10-12
0-10-12
1-2-15
6-7-2
9-1-13
9-3-7
1-2-15
2-0-0
8-10-5
5.0012
6.0012
PlateOffsets(X,Y)-- [2:0-2-12,0-2-8], [6:0-3-8,0-2-8], [9:0-2-12,0-3-0], [17:0-7-0,0-0-8], [28:0-5-8,0-3-8], [33:0-1-6,0-1-0], [34:0-1-9,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.42
0.42
0.97
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.21
-0.52
0.20
(loc)
26
26-27
17
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 692 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x6SPF No.2
BOT CHORD2x6SP 2400F 2.0E*Except*
B1: 2x4SP 2400F 2.0E,B3,F1,F4: 2x4SPFStud
WEBS 2x4SPFStud*Except*
W3,F2: 2x6SPF No.2, W19: 2x4 HF/SPF No.2
SLIDER Right 2x6SP 2400F 2.0E 1-6-0
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except:
6-0-0 oc bracing: 28-29.
REACTIONS. (lb/size)34=1864/0-6-0(min. 0-1-8), 17=1845/0-6-0(min. 0-1-8)
Max Horz34=178(LC 16)
Max Uplift34=-349(LC 16), 17=-207(LC 17)
MaxGrav34=2151(LC 43), 17=2151(LC 43)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-34=-2116/447, 2-43=-5210/1022, 3-43=-5135/1022, 3-44=-4988/877, 4-44=-4949/889,
4-45=-4408/800, 45-46=-4337/806, 5-46=-4305/808, 5-6=-3972/777, 6-47=-4944/958,
7-47=-4944/957, 7-48=-5508/1044, 48-49=-5508/1044, 8-49=-5508/1044,
8-50=-5634/1067, 9-50=-5632/1067, 9-51=-4682/908, 10-51=-4656/917, 10-52=-3778/772,
11-52=-3696/779, 11-53=-3447/744, 12-53=-3447/744, 12-54=-3243/664,
54-55=-3337/645, 13-55=-3348/643, 13-14=-3634/651, 14-15=-3689/638,
15-56=-3368/570, 56-57=-3465/556, 16-57=-3477/553, 16-17=-1027/134
BOT CHORD 32-33=-1066/4669, 31-32=-930/4604, 30-31=-767/4015, 29-30=-65/337, 7-28=-763/173,
27-28=-873/4980, 26-27=-914/5508, 25-26=-933/5628, 24-25=-680/4268,
23-24=-680/4268, 22-23=-397/3014, 21-22=-397/3014, 20-21=-470/3386,
19-20=-425/3060, 17-19=-425/3060
WEBS 2-33=-864/4506, 4-31=-701/194, 5-31=-48/369, 5-30=-579/161, 6-30=-1447/240,
28-30=-691/3867, 6-28=-494/2995, 7-27=-118/758, 8-27=-529/152, 8-26=-60/321,
9-25=-2300/446, 10-25=-321/1822, 10-23=-1710/388, 11-23=-152/1159, 12-23=-214/894,
12-21=-63/438, 13-21=-527/175, 15-20=-61/471, 15-19=-326/113
NOTES-
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x6- 2 rowsstaggered at 0-9-0 oc.
Bottomchordsconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x6- 2 rowsstaggered at 0-9-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x6- 2 rowsstaggered at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3) Unbalancedroofliveloads have been considered for this design.
4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-12 to 4-0-1,Interior(1) 4-0-1 to 13-2-0,Exterior(2) 13-2-0 to 18-0-13,
Interior(1) 23-2-6 to 29-4-0,Exterior(2) 34-6-0 to 39-2-13zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
Continued on page 2
B4 B3
HW1
HW2
1 2
3
4
5
6
7 8
9 10
11
12
1314
15 16
17
18
19
20
34 33 32
31
30 29 28 27 26
2524 23
22 21
43
44
45
46 47 4849 50
51
52
53
54
55
56
6x8
8x10 8x8
5x6 6x6
4x6
5x12MT18H
5x6
3x6
6x8
4x6
3x6 5x10
4x6
8x10
4x8
3x6 4x8
3x6
3x6
5x6
5x6
4x8
4x6
4x4
4x6
4x4
6x8 3x6
5x12MT18H
4x6
5-3-8
5-3-8
10-3-8
5-0-0
15-2-0
4-10-8
18-7-10
3-5-10
21-11-12
3-4-2
25-3-14
3-4-2
28-4-11
3-0-13
31-5-8
3-0-13
32-4-8
0-11-0
37-9-13
5-5-5
43-3-3
5-5-5
49-0-0
5-8-13
-0-10-12
0-10-12
5-3-8
5-3-8
10-3-8
5-0-0
15-3-8
5-0-0
18-7-10
3-4-2
21-11-12
3-4-2
25-3-14
3-4-2
28-4-11
3-0-13
31-5-8
3-0-13
32-4-8
0-11-0
37-9-13
5-5-5
43-3-3
5-5-5
49-0-0
5-8-13
49-10-12
0-10-12
1-2-15
7-5-12
10-0-7
10-2-1
1-2-15
2-0-0
5.0012
PlateOffsets(X,Y)-- [2:0-4-12,0-1-6], [7:0-0-12,0-1-12], [8:0-6-4,Edge], [8:0-3-2,0-0-0], [11:0-2-12,0-3-4], [19:0-7-4,0-0-1], [31:0-3-4,0-5-4], [33:0-1-8,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.30
0.69
0.94
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.26
-0.63
0.20
(loc)
28
28-29
19
l/defl
>999
>936
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 440 lb FT= 20%
GRIP
185/144
197/144
LUMBER-
TOP CHORD2x6SP 2400F 2.0E*Except*
T2,T3,T1: 2x8SP 2400F 2.0E
BOT CHORD2x8SP 2400F 2.0E*Except*
B2: 2x4SPFStud
WEBS 2x4SPFStud*Except*
W5,W14,W15: 2x4 HF/SPF No.2
SLIDER Left 2x6SPF No.2 2-0-0, Right 2x6SPF No.2 2-0-0
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-10-5 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 11-27, 12-25
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)2=1846/0-6-0(min. 0-1-13), 19=1818/0-6-0(min. 0-1-13)
Max Horz2=212(LC 16)
Max Uplift2=-363(LC 16), 19=-229(LC 17)
MaxGrav2=2181(LC 43), 19=2196(LC 43)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-2034/311, 3-43=-3582/559, 43-44=-3564/562, 44-45=-3484/574, 4-45=-3471/574,
4-5=-3755/618, 5-6=-3653/631, 6-46=-4701/831, 7-46=-4613/848, 7-8=-4216/809,
8-47=-4294/818, 9-47=-4295/817, 9-48=-4939/865, 48-49=-4939/865, 10-49=-4939/865,
10-50=-4944/868, 11-50=-4942/868, 11-51=-4252/729, 51-52=-4234/732,
12-52=-4221/741, 12-13=-3522/648, 13-14=-3222/621, 14-53=-3364/624,
15-53=-3464/602, 15-16=-3756/613, 16-54=-3856/599, 54-55=-3856/596,
17-55=-3897/591, 17-56=-3693/563, 18-56=-3782/543, 18-19=-1511/171
BOT CHORD 2-34=-654/3160, 33-34=-654/3160, 7-31=-198/1444, 30-31=-796/4655, 29-30=-796/4655,
28-29=-733/4920, 27-28=-732/4922, 26-27=-506/3877, 25-26=-506/3877,
24-25=-331/3112, 23-24=-408/3560, 22-23=-408/3560, 21-22=-414/3388,
19-21=-414/3388
WEBS 4-34=-276/105, 4-33=-40/381, 6-33=-1370/312, 31-33=-673/3599, 6-31=-132/1043,
9-31=-739/124, 9-29=-65/501, 10-29=-463/129, 11-29=-108/329, 11-27=-2047/432,
12-27=-293/1569, 12-25=-1519/366, 13-25=-183/1020, 14-25=-186/819, 14-24=-50/358,
15-24=-627/204, 17-22=-46/276, 17-21=-305/104
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-12 to 4-0-1,Interior(1) 4-0-1 to 15-3-8,Exterior(2) 15-3-8 to 20-2-5,
Interior(1) 25-3-14 to 31-5-8,Exterior(2) 32-4-8 to 37-3-5zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
Continued on page 2
8 9
10
11
12
13
14
15
16
17
29 28 27
26
25 24 23 22
21 20
19 18
38
39
40
41
4243 44
45
46
47
48
4x6
6x8 6x8
5x6
5x6
5x10
4x8
3x5
3x4
5x6
4x4
2x4 5x10
4x4
8x12MT18H
2x4
4x8
2x4
2x4
5x8
4x4
4x4
4x4
2x4 5x10
4x8
4x6
5-9-4
5-9-4
10-2-8
4-5-4
15-2-0
4-11-8
17-3-8
2-1-8
22-3-11
5-0-3
27-3-14
5-0-3
31-11-0
4-7-2
37-10-11
5-11-11
43-1-5
5-2-10
49-0-0
5-10-11
-0-10-12
0-10-12
5-9-4
5-9-4
10-2-8
4-5-4
15-2-0
4-11-8
17-3-8
2-1-8
22-3-11
5-0-3
27-3-14
5-0-3
31-11-0
4-7-2
37-10-11
5-11-11
43-1-5
5-2-10
49-0-0
5-10-11
49-10-12
0-10-12
1-2-15
8-3-12
10-4-6
1-2-15
2-0-0
5.0012
PlateOffsets(X,Y)-- [8:0-2-0,0-2-4], [10:0-2-12,0-3-0], [26:0-3-12,0-4-0], [28:0-1-8,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.36
0.47
0.81
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.26
-0.66
0.22
(loc)
23-24
23-24
16
l/defl
>999
>888
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 364 lb FT= 20%
GRIP
185/144
185/144
LUMBER-
TOP CHORD2x6SP 2400F 2.0E*Except*
T3,T4,T5: 2x6SPF No.2
BOT CHORD2x6SP 2400F 2.0E
WEBS 2x4SPFStud*Except*
W5,W8,W12,W13: 2x4 HF/SPF No.2
SLIDER Left 2x6SP 2400F 2.0E 2-6-0, Right 2x6SP 2400F 2.0E 2-6-0
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-5-8 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 10-21
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)2=1835/0-6-0(min. 0-1-11), 16=1826/0-6-0(min. 0-1-11)
Max Horz2=214(LC 16)
Max Uplift2=-361(LC 16), 16=-234(LC 17)
MaxGrav2=2014(LC 2), 16=2014(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-349/42, 3-38=-3358/583, 4-38=-3282/598, 4-5=-3460/624, 5-39=-3457/629,
6-39=-3434/642, 6-40=-4366/832, 40-41=-4293/834, 7-41=-4272/841, 7-8=-4290/884,
8-42=-4080/769, 42-43=-4080/769, 9-43=-4081/769, 9-44=-4082/768, 10-44=-4080/769,
10-45=-3068/527, 11-45=-3034/541, 11-46=-2968/549, 46-47=-3018/536,
12-47=-3092/535, 12-48=-3347/541, 13-48=-3408/527, 13-14=-3444/527,
14-15=-3365/487, 15-16=-347/32
BOT CHORD 2-29=-674/2968, 28-29=-674/2968, 27-28=-61/320, 25-26=-671/3748, 24-25=-671/3741,
23-24=-606/4001, 22-23=-605/4003, 21-22=-605/4003, 20-21=-349/3167,
19-20=-349/3167, 18-19=-348/2976, 16-18=-348/2976
WEBS 4-28=-10/323, 6-28=-1245/291, 26-28=-643/3121, 6-26=-115/912, 8-26=-218/877,
8-25=-3/312, 8-24=-82/562, 9-24=-540/171, 10-24=-113/267, 10-21=-1982/447,
11-21=-295/2035, 12-21=-630/213, 14-19=-52/292
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-12 to 2-1-4,Interior(1) 2-1-4 to 17-3-8,Exterior(2) 17-3-8 to 20-3-8,
Interior(1) 27-3-14 to 49-10-12zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and
forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
Continued on page 2
11
12
13
14
15
16
17
18
31 30 29
28
27 26 25 24 23
22 21
20 19
40
41 42
43 44 45
46
47
5x6
6x8 6x8
5x6
5x6
5x10
4x8
3x5
3x4
5x6
4x4
2x4 5x10
4x4
8x12MT18H
2x4
4x4
4x4 2x4
4x8
2x4 5x8
4x4
4x4
4x4
2x4 5x10
4x8
4x6
5-9-4
5-9-4
10-2-8
4-5-4
15-2-0
4-11-8
19-3-8
4-1-8
22-7-1
3-3-9
26-0-6
3-5-5
29-3-14
3-3-9
31-11-0
2-7-2
37-10-11
5-11-11
43-1-5
5-2-10
49-0-0
5-10-11
-0-10-12
0-10-12
5-9-4
5-9-4
10-2-8
4-5-4
15-2-0
4-11-8
19-3-8
4-1-8
22-7-1
3-3-9
26-0-6
3-5-5
29-3-14
3-3-9
31-11-0
2-7-2
37-10-11
5-11-11
43-1-5
5-2-10
49-0-0
5-10-11
49-10-12
0-10-12
1-2-15
9-1-12
10-4-6
1-2-15
2-0-0
5.0012
PlateOffsets(X,Y)-- [8:0-2-4,0-1-12], [11:0-2-12,0-3-0], [28:0-3-12,0-4-0], [30:0-1-8,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.37
0.47
0.82
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.25
-0.64
0.22
(loc)
25
25-26
17
l/defl
>999
>924
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 377 lb FT= 20%
GRIP
185/144
185/144
LUMBER-
TOP CHORD2x6SPF No.2 *Except*
T1,T6: 2x6SP 2400F 2.0E
BOT CHORD2x6SP 2400F 2.0E
WEBS 2x4SPFStud*Except*
W5,W6,W12,W13: 2x4 HF/SPF No.2
SLIDER Left 2x6SP 2400F 2.0E 2-6-0, Right 2x6SP 2400F 2.0E 2-6-0
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-4-11 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 11-22
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)2=1831/0-6-0(min. 0-1-11), 17=1830/0-6-0(min. 0-1-11)
Max Horz2=214(LC 16)
Max Uplift2=-361(LC 16), 17=-234(LC 17)
MaxGrav2=2014(LC 2), 17=2014(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-359/44, 3-4=-3348/602, 4-5=-3460/625, 5-40=-3455/630, 6-40=-3378/642,
6-7=-4380/844, 7-41=-4373/907, 41-42=-4350/912, 8-42=-4339/925, 8-43=-3562/701,
9-43=-3564/701, 9-10=-3576/665, 10-44=-3579/666, 44-45=-3578/666, 11-45=-3577/667,
11-12=-3049/552, 12-46=-3025/549, 13-46=-3097/535, 13-47=-3345/540,
14-47=-3406/526, 14-15=-3442/526, 15-16=-3366/487, 16-17=-347/31
BOT CHORD 2-31=-676/2960, 30-31=-676/2960, 29-30=-61/302, 7-28=-297/150, 27-28=-584/3433,
26-27=-585/3428, 25-26=-577/3563, 24-25=-473/3392, 23-24=-472/3391,
22-23=-472/3391, 21-22=-355/3164, 20-21=-355/3164, 19-20=-353/2977,
17-19=-353/2977
WEBS 4-30=-4/302, 6-30=-1243/288, 28-30=-642/3137, 6-28=-122/934, 8-28=-324/1316,
8-27=0/256, 8-26=-72/412, 9-26=-339/103, 10-25=-367/114, 11-25=-158/534,
11-22=-1669/395, 12-22=-325/2061, 13-22=-619/211, 15-20=-52/289
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-12 to 2-1-4,Interior(1) 2-1-4 to 19-3-8,Exterior(2) 19-3-8 to 22-7-1,
Interior(1) 29-3-14 to 49-10-12zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and
forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
Continued on page 2
12
13
14
15
16
17
29 28 27
26
25 24 23 22
21 20
19 18
38
39
40
41 42 4344
45
46
47
5x6
6x6
6x6
5x6
5x10
4x8
3x5
3x4
4x6
4x4
2x4 5x10
4x4
8x12MT18H
4x10
2x4
4x6
2x4
4x8
4x4
4x4
4x4
4x4
2x4 5x12
4x8
4x6
5-9-4
5-9-4
10-2-8
4-5-4
15-2-0
4-11-8
18-2-12
3-0-12
21-3-8
3-0-12
26-10-13
5-7-5
32-6-2
5-7-5
37-9-8
5-3-6
43-3-11
5-6-3
49-0-0
5-8-5
-0-10-12
0-10-12
5-9-4
5-9-4
10-2-8
4-5-4
15-2-0
4-11-8
18-2-12
3-0-12
21-3-8
3-0-12
26-10-13
5-7-5
32-6-2
5-7-5
37-9-8
5-3-6
43-3-11
5-6-3
49-0-0
5-8-5
49-10-12
0-10-12
1-2-15
9-11-12
10-1-6
1-2-15
2-0-0
5.0012
PlateOffsets(X,Y)-- [16:0-8-12,0-0-8], [26:0-3-12,0-4-0], [28:0-1-12,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.45
0.51
0.86
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.26
-0.61
0.22
(loc)
25-26
25-26
16
l/defl
>999
>961
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 365 lb FT= 20%
GRIP
185/144
185/144
LUMBER-
TOP CHORD2x6SPF No.2 *Except*
T1,T5: 2x6SP 2400F 2.0E
BOT CHORD2x6SP 2400F 2.0E
WEBS 2x4SPFStud*Except*
W5,W9,W10,W11: 2x4 HF/SPF No.2
SLIDER Left 2x6SP 2400F 2.0E 2-6-0, Right 2x6SP 2400F 2.0E 2-6-0
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-3-5 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 8-24, 9-23
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)2=1831/0-6-0(min. 0-1-11), 16=1842/0-6-0(min. 0-1-12)
Max Horz2=208(LC 16)
Max Uplift2=-276(LC 16), 16=-228(LC 17)
MaxGrav2=2060(LC 39), 16=2121(LC 39)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-367/32, 3-4=-3490/470, 4-5=-3679/514, 5-38=-3665/518, 6-38=-3630/530,
6-39=-4642/683, 7-39=-4549/696, 7-40=-4630/743, 8-40=-4569/750, 8-9=-3494/632,
9-41=-3183/609, 41-42=-3184/609, 10-42=-3185/609, 10-43=-3185/609, 43-44=-3184/609,
11-44=-3183/609, 11-45=-3130/573, 12-45=-3229/552, 12-13=-3624/568,
13-46=-3626/550, 14-46=-3660/546, 14-47=-3578/499, 15-47=-3611/481, 15-16=-373/42
BOT CHORD 2-29=-529/3088, 28-29=-529/3088, 27-28=-42/333, 7-26=-297/137, 25-26=-436/3681,
24-25=-436/3681, 23-24=-352/3188, 22-23=-314/2891, 21-22=-314/2891,
20-21=-396/3347, 19-20=-396/3347, 18-19=-385/3196, 16-18=-385/3196
WEBS 4-28=-9/378, 6-28=-1369/223, 26-28=-469/3325, 6-26=-102/953, 8-26=-277/1211,
8-24=-1132/271, 9-24=-186/1101, 9-23=-160/318, 10-23=-575/189, 11-23=-121/710,
11-21=-81/566, 12-21=-648/200, 14-19=-13/305
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-12 to 2-1-4,Interior(1) 2-1-4 to 21-3-8,Exterior(2) 21-3-8 to 36-9-0,
Interior(1) 36-9-0 to 49-10-12zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and
forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
Continued on page 2
7
8 9 10
11
12
13
14
15
16
28 27 26
25
24 23 22 21
20 19
18 17
37
38
3940 41
42
43
44
4x6
6x6
6x6
5x6
5x12
4x8
3x5
3x4
4x6
4x4
2x4 5x10
4x4
8x12MT18H
4x12
2x4
4x6
2x4
4x8
4x4
4x4
4x4
4x4
2x4 6x12
4x8
5x6
5-9-4
5-9-4
10-2-8
4-5-4
15-2-0
4-11-8
19-2-12
4-0-12
23-3-8
4-0-12
26-10-13
3-7-5
30-6-2
3-7-5
36-6-14
6-0-13
42-7-11
6-0-13
49-0-0
6-4-5
5-9-4
5-9-4
10-2-8
4-5-4
15-2-0
4-11-8
19-2-12
4-0-12
23-3-8
4-0-12
26-10-13
3-7-5
30-6-2
3-7-5
36-6-14
6-0-13
42-7-11
6-0-13
49-0-0
6-4-5
49-10-12
0-10-12
1-2-15
10-9-12
10-11-6
1-2-15
2-0-0
5.0012
PlateOffsets(X,Y)-- [1:0-7-12,0-0-4], [25:0-3-8,0-4-0], [27:0-1-8,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.49
0.57
0.89
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.28
-0.64
0.24
(loc)
24-25
24-25
15
l/defl
>999
>922
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 372 lb FT= 20%
GRIP
185/144
185/144
LUMBER-
TOP CHORD2x6SPF No.2 *Except*
T1,T5: 2x6SP 2400F 2.0E
BOT CHORD2x6SP 2400F 2.0E
WEBS 2x4 HF/SPF No.2 *Except*
W1,W2,W3,W4,W7,W13,W14,W15: 2x4SPFStud
SLIDER Left 2x6SP 2400F 2.0E 2-6-0, Right 2x6SP 2400F 2.0E 2-6-0
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-1-12 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 7-23, 8-22, 9-22, 11-20
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=1767/0-6-0(min. 0-1-11), 15=1820/0-6-0(min. 0-1-13)
Max Horz1=210(LC 16)
Max Uplift1=-272(LC 16), 15=-248(LC 17)
MaxGrav1=2058(LC 39), 15=2170(LC 39)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-382/39, 2-37=-3571/459, 3-37=-3550/476, 3-4=-3781/507, 4-5=-3726/519,
5-38=-4864/667, 6-38=-4725/668, 6-7=-4890/730, 7-8=-3409/586, 8-39=-3049/565,
9-39=-3050/565, 9-40=-3050/564, 10-40=-3049/565, 10-41=-3101/554, 41-42=-3154/542,
11-42=-3267/529, 11-43=-3735/555, 12-43=-3757/538, 12-13=-3797/532,
13-44=-3708/496, 14-44=-3786/475, 14-15=-402/26
BOT CHORD 1-28=-570/3158, 27-28=-570/3158, 26-27=-46/328, 6-25=-345/154, 24-25=-400/3736,
23-24=-400/3736, 22-23=-287/3082, 21-22=-273/2912, 20-21=-273/2912,
19-20=-370/3468, 18-19=-370/3468, 17-18=-379/3367, 15-17=-379/3367
WEBS 3-27=-6/413, 5-27=-1432/225, 25-27=-517/3438, 5-25=-94/1085, 7-25=-318/1345,
7-23=-1268/301, 8-23=-203/1117, 9-22=-365/113, 10-22=-130/555, 10-20=-98/608,
11-20=-773/227, 11-18=0/267
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-0-0 to 3-0-0,Interior(1) 3-0-0 to 23-3-8,Exterior(2) 23-3-8 to 34-9-0,
Interior(1) 34-9-0 to 49-10-12zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and
forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
Continued on page 2
8 9
10
11
12
13
14
15
26 25 24
23
22 21 20 19 18
17 16
35
36
37
38 39
40
41
42
4x6
6x6
5x6
5x6
5x12
4x8
3x5
3x4
5x6
4x4
2x4 5x10
4x4
8x12MT18H
4x12
2x4
4x6
4x8
4x4
4x4
4x4
2x4 6x12
4x8
5x6
5-3-0
5-3-0
10-2-8
4-11-8
15-2-0
4-11-8
20-2-12
5-0-12
25-3-8
5-0-12
28-6-2
3-2-10
35-5-14
6-11-12
41-11-4
6-5-6
49-0-0
7-0-12
5-3-0
5-3-0
10-2-8
4-11-8
15-2-0
4-11-8
20-2-12
5-0-12
25-3-8
5-0-12
28-6-2
3-2-10
35-5-14
6-11-12
41-11-4
6-5-6
49-0-0
7-0-12
49-10-12
0-10-12
1-2-15
11-7-12
11-9-6
1-2-15
2-0-0
5.0012
PlateOffsets(X,Y)-- [1:0-8-12,0-0-8], [23:0-3-8,0-4-0], [25:0-1-8,0-2-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.50
0.61
0.92
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.28
-0.62
0.25
(loc)
22-23
22-23
14
l/defl
>999
>951
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 373 lb FT= 20%
GRIP
185/144
185/144
LUMBER-
TOP CHORD2x6SP 2400F 2.0E*Except*
T3,T4: 2x6SPF No.2
BOT CHORD2x6SP 2400F 2.0E
WEBS 2x4SPFStud*Except*
W5,W6,W8,W9,W10,W11: 2x4 HF/SPF No.2
SLIDER Left 2x6SP 2400F 2.0E 2-6-0, Right 2x6SP 2400F 2.0E 2-6-0
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-1-9 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 7-21, 8-20, 10-20
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)1=1749/0-6-0(min. 0-1-12), 14=1798/0-6-0(min. 0-1-13)
Max Horz1=224(LC 16)
Max Uplift1=-287(LC 16), 14=-266(LC 17)
MaxGrav1=2092(LC 39), 14=2216(LC 39)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-388/53, 2-35=-3593/479, 3-35=-3572/495, 3-4=-3863/522, 4-36=-5014/666,
5-36=-4944/676, 5-6=-4910/685, 6-37=-5082/762, 7-37=-5007/777, 7-38=-3321/521,
8-38=-3228/542, 8-9=-2923/524, 9-39=-3171/525, 39-40=-3211/506, 10-40=-3298/497,
10-41=-3739/528, 11-41=-3848/510, 11-42=-3906/509, 12-42=-3909/498,
12-13=-3928/486, 13-14=-397/2
BOT CHORD 1-26=-609/3172, 25-26=-609/3172, 24-25=-49/309, 6-23=-354/165, 22-23=-424/3769,
21-22=-424/3769, 20-21=-233/2976, 19-20=-332/3566, 18-19=-332/3566,
17-18=-332/3566, 16-17=-359/3499, 14-16=-359/3499
WEBS 3-25=-8/459, 4-25=-1467/257, 23-25=-564/3537, 4-23=-84/1184, 7-23=-356/1440,
7-22=0/274, 7-21=-1374/333, 8-21=-220/1157, 8-20=-348/142, 9-20=-92/870,
10-20=-862/256, 10-17=0/318
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-0-0 to 3-0-0,Interior(1) 3-0-0 to 25-3-8,Exterior(2) 25-3-8 to 28-6-2,
Interior(1) 32-9-0 to 49-10-12zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and
forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
Continued on page 2
5x8
4x6 3x6
3x4
6x6 3x4
3x4
3x4
5x8
1.5x4
4x8 4x6
6x8
3x4
4x6
3x6
7-2-6
7-2-6
14-1-4
6-10-14
21-0-2
6-10-14
26-10-13
5-10-10
32-9-7
5-10-10
39-0-0
6-2-9
7-2-6
7-2-6
14-1-4
6-10-14
21-0-2
6-10-14
26-10-13
5-10-10
32-9-7
5-10-10
39-0-0
6-2-9
1-2-15
10-0-0
7-4-15
10-0-0
5.0012
PlateOffsets(X,Y)-- [5:0-5-4,0-2-4], [7:0-5-4,0-2-4], [16:0-3-0,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.89
0.73
0.98
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.15
-0.41
0.10
(loc)
15-16
13-15
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 211 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W3,W5,W1,W2,W10: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied, except end verticals.
BOT CHORD Rigidceiling directly applied or 7-6-12 oc bracing.
WEBS 1 Row at midpt 4-13, 5-11, 6-11, 7-10, 8-9
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)17=1407/0-6-0(min. 0-2-10), 9=1452/0-6-0(min. 0-2-9)
Max Horz17=282(LC 16)
Max Uplift17=-217(LC 16), 9=-204(LC 12)
MaxGrav17=1578(LC 38), 9=1548(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-18=-2724/339, 2-18=-2663/358, 2-19=-2478/342, 3-19=-2385/343, 3-4=-2288/371,
4-20=-1783/323, 20-21=-1773/336, 5-21=-1674/355, 5-22=-1342/330, 6-22=-1342/330,
6-23=-1342/330, 23-24=-1342/330, 7-24=-1342/330, 7-25=-917/221, 25-26=-920/205,
8-26=-987/201, 1-17=-1506/253, 8-9=-1493/322
BOT CHORD 16-17=-339/267, 15-16=-556/2458, 14-15=-414/2202, 13-14=-414/2202, 12-13=-275/1554,
11-12=-275/1554, 10-11=-136/836
WEBS 2-15=-313/164, 4-15=0/397, 4-13=-938/264, 5-13=-105/782, 5-11=-574/154,
6-11=-570/188, 7-11=-186/1010, 7-10=-833/238, 1-16=-219/2286, 8-10=-206/1276
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 21-0-2,Exterior(2) 21-0-2 to 37-0-6,
Interior(1) 37-0-6 to 38-10-4zone;cantileverleft exposed ; end verticalleft exposed;C-C formembers and forces&MWFRS for
reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
17=217, 9=204.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
5x8
4x4
5x6
7-2-6
7-2-6
14-1-4
6-10-14
21-0-2
6-10-14
29-0-0
7-11-14
7-2-6
7-2-6
14-1-4
6-10-14
21-0-2
6-10-14
24-10-5
3-10-3
29-0-0
4-1-11
1-2-15
10-0-0
5.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.74
0.59
0.71
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.11
-0.29
0.06
(loc)
8-9
8-9
8
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 155 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W3,W5,W1,W2: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-0-14 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 7-10-14 oc bracing.
WEBS 1 Row at midpt 7-8, 4-9, 5-9, 6-8
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)8=1084/0-6-0(min. 0-1-14), 13=1027/0-6-0(min. 0-2-0)
Max Horz13=341(LC 16)
Max Uplift8=-202(LC 12), 13=-156(LC 16)
MaxGrav8=1148(LC 2), 13=1208(LC 35)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-14=-2010/223, 2-14=-1949/241, 2-15=-1655/175, 3-15=-1562/176, 3-4=-1465/204,
4-16=-924/102, 16-17=-796/107, 5-17=-794/121, 5-6=-734/151, 1-13=-1138/193
BOT CHORD 12-13=-394/292, 11-12=-508/1799, 10-11=-350/1442, 9-10=-350/1442, 8-9=-97/407
WEBS 2-11=-432/181, 4-11=-12/425, 4-9=-984/278, 6-9=-184/935, 6-8=-1057/258,
1-12=-114/1639
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 21-0-2,Exterior(2) 21-0-2 to 25-3-1
zone;cantileverleft exposed ; end verticalleft exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber
DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
3) Unbalancedsnowloads have been considered for this design.
4)Provide adequate drainage to preventwater ponding.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
8=202, 13=156.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
8x8
5x8
5x6
5x6
5-5-11
5-5-11
10-7-13
5-2-3
15-10-0
5-2-3
21-0-2
5-2-3
25-0-1
3-11-15
29-0-0
3-11-15
5-5-11
5-5-11
10-7-13
5-2-3
15-10-0
5-2-3
21-0-2
5-2-3
25-0-1
3-11-15
29-0-0
3-11-15
1-2-15
10-0-0
5.0012
PlateOffsets(X,Y)-- [1:0-11-2,Edge], [5:0-3-8,0-3-0], [5:0-0-0,0-1-12], [7:0-5-4,0-2-4], [8:0-2-8,0-2-0], [11:0-2-8,0-2-0], [12:0-3-8,0-4-0], [13:0-3-8,0-5-12], [15:0-3-8,0-6-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.98
0.63
0.91
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.22
-0.46
0.06
(loc)
15-16
15-16
10
l/defl
>999
>747
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 683 lb FT= 20%
GRIP
185/144
197/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2 *Except*
T1: 2x4SPF 2100F 1.8E
BOT CHORD2x8SP 2400F 2.0E
WEBS 2x4SPFStud*Except*
W7,W6: 2x4 HF/SPF No.2, W8: 2x4SPF 1650F 1.5E
SLIDER Left 2x8SP 2400F 2.0E 2-6-0
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-11-15 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 9-10
REACTIONS. (lb/size)10=9415/0-6-0(min. 0-2-10), 1=8671/0-6-0(min. 0-2-7)
Max Horz1=358(LC 12)
Max Uplift10=-1714(LC 8), 1=-1549(LC 12)
MaxGrav10=9419(LC 31), 1=8851(LC 31)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-7265/1206, 2-3=-14130/2482, 3-21=-13636/2357, 4-21=-13585/2372,
4-5=-10230/1762, 5-6=-10218/1786, 6-22=-6173/1082, 7-22=-6081/1096, 7-8=-3344/610
BOT CHORD 1-24=-2553/12826, 24-25=-2553/12826, 16-25=-2553/12826, 16-26=-2553/12826,
26-27=-2553/12826, 27-28=-2553/12826, 15-28=-2553/12826, 15-29=-2408/12590,
14-29=-2408/12590, 14-30=-2408/12590, 13-30=-2408/12590, 13-31=-1769/9358,
31-32=-1769/9358, 12-32=-1769/9358, 12-33=-1062/5727, 33-34=-1062/5727,
11-34=-1062/5727, 11-35=-610/3344, 35-36=-610/3344, 10-36=-610/3344
WEBS 3-16=-203/829, 3-15=-367/168, 4-15=-696/4034, 4-13=-4590/907, 6-13=-1118/6311,
6-12=-6409/1247, 7-12=-1409/7794, 7-11=-6177/1170, 8-11=-1464/8150,
8-10=-8918/1627
NOTES-
1) 3-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-4-0 oc.
Bottomchordsconnected as follows: 2x8- 2 rowsstaggered at 0-6-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft exposed ; end verticalleft exposed; Lumber DOL=1.60 plate grip DOL=1.60
4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
5) Unbalancedsnowloads have been considered for this design.
6)Provide adequate drainage to preventwater ponding.
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
Continued on page 2
6-0-12
13-6-10
7-5-14
21-4-0
7-9-6
6-0-12
6-0-12
13-6-10
7-5-14
21-4-0
7-9-6
23-6-12
2-2-12
11-6-0
1-3-13
11-6-0
8.0012
PlateOffsets(X,Y)-- [2:0-3-12,0-2-0], [5:0-3-0,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.93
0.48
0.66
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.09
-0.23
0.02
(loc)
7-8
7-8
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 124 lb FT= 20%
GRIP
185/144
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W5,W7: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-2-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 1-11, 2-11, 4-10
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)11=789/0-6-0(min. 0-1-8), 7=881/0-4-0(min. 0-1-12)
Max Horz11=-453(LC 17)
Max Uplift11=-205(LC 17), 7=-99(LC 17)
MaxGrav11=839(LC 35), 7=1080(LC 36)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-11=-266/88, 2-14=-354/53, 14-15=-455/33, 3-15=-473/31, 3-4=-687/7, 4-16=-935/40,
16-17=-1157/13, 5-17=-1174/0, 5-7=-1009/158
BOT CHORD 10-11=-69/463, 9-10=0/893, 8-9=0/893, 7-8=-53/320
WEBS 2-11=-820/242, 2-10=-93/579, 4-10=-677/278, 4-8=0/261, 5-8=0/788
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 6-0-12,Exterior(2) 6-0-12 to 9-0-12
zone;cantileverright exposed ; end verticalright exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber
DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)Provide adequate drainage to preventwater ponding.
6)All plates areMT20 plates unless otherwiseindicated.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 7 except(jt=lb)
11=205.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
ST14
ST11 ST15
ST16 ST17
ST18
ST19
ST20
ST21
ST22
1
2
3 4 5
6
7
8
9
25 24 23 2221 20 19 18 16
15 14
13 1110
63
64
65
66
67
68
69
70
17
12
4x6
5x6
5x6
3x6
2x4 3x6
3x8
3x5
3x4
3x5
4x4 2x4
4x10
4x4
4x8 3x6
2x4 2x4
2x4
2x4 2x4
2x4
2x4 2x4
2x4
2x4
2x4
6-3-6
6-3-6
12-3-5
5-11-14
13-10-8
1-7-3
21-0-12
7-2-4
28-6-10
7-5-14
34-3-8
5-8-14
36-4-0
2-0-8
6-3-6
6-3-6
12-3-5
5-11-14
16-8-0
4-4-11
21-0-12
4-4-11
28-6-10
7-5-14
36-4-0
7-9-6
38-6-12
2-2-12
3-3-13
11-6-0
1-3-13
11-6-0
8.0012
PlateOffsets(X,Y)-- [3:0-3-0,0-2-3], [5:0-3-0,0-2-3], [39:0-1-15,0-0-12], [41:0-1-15,0-0-12], [62:0-1-11,0-0-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.88
0.43
0.63
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.06
-0.17
0.02
(loc)
13-15
13-15
10
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 342 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2 *Except*
T2: 2x6SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W3,W8,W1,W2: 2x4SPFStud,W10: 2x6SPF No.2
OTHERS 2x4SPFStud*Except*
ST14,ST11,ST10,ST15,ST16: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-2-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 2-19, 3-19, 4-19, 5-15, 7-15
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 14-2-0 except(jt=length) 10=2-4-0, 11=2-4-0, 17=0-3-8, 12=0-3-8.
(lb)-Max Horz25=-361(LC 12)
Max UpliftAll uplift 100 lb orless at joint(s) 25 except 19=-159(LC 16),
22=-135(LC 16), 10=-199(LC 17), 18=-490(LC 7), 11=-126(LC 39)
MaxGravAllreactions 250 lb orless at joint(s) 25, 20, 21, 23, 24, 12 except
19=1546(LC 39), 22=358(LC 47), 10=1090(LC 39), 17=654(LC 7)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 3-66=0/403, 4-5=-464/255, 5-68=-472/228, 6-68=-503/200, 6-7=-671/183,
7-69=-884/204, 69-70=-1106/177, 8-70=-1122/153, 8-10=-991/279
BOT CHORD 24-25=-298/339, 23-24=-298/339, 22-23=-298/339, 18-19=-135/292, 17-18=-135/292,
16-17=-135/292, 15-16=-135/292, 14-15=-8/849, 13-14=-8/849, 12-13=-105/290,
11-12=-105/290, 10-11=-105/290
WEBS 2-19=-315/169, 2-22=-261/127, 3-19=-486/60, 8-13=-19/783, 4-19=-885/182,
4-15=-123/772, 7-15=-627/266
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 12-3-5,Exterior(2) 12-3-5 to 25-3-10,
Interior(1) 25-3-10 to 38-6-12zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and
forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
7)Provide adequate drainage to preventwater ponding.
8)All plates are 1.5x4MT20 unless otherwiseindicated.
9)Gablestudsspaced at 2-0-0 oc.
Continued on page 2
25
5x6
5x6
5x6
3x6
3x4 3x6
3x5
3x8 3x8
3x4
3x8
3x5
4x6 4x6
6x12MT18H
3x6
6-3-6
6-3-6
12-3-5
5-11-14
21-0-12
8-9-7
28-6-10
7-5-14
36-4-0
7-9-6
6-3-6
6-3-6
12-3-5
5-11-14
16-8-0
4-4-11
21-0-12
4-4-11
28-6-10
7-5-14
36-4-0
7-9-6
38-6-12
2-2-12
3-3-13
11-6-0
1-3-13
11-6-0
8.0012
PlateOffsets(X,Y)-- [3:0-3-12,0-2-0], [5:0-3-8,0-2-8], [8:0-3-0,0-1-8], [10:Edge,0-2-0], [16:0-3-8,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.95
0.63
0.57
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.13
-0.38
0.07
(loc)
13-15
13-15
10
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
MT18H
Weight: 204 lb FT= 20%
GRIP
185/144
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2 *Except*
T3: 2x4SPF 1650F 1.5E
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W3,W8,W1,W2,W10: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied, except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except:
6-0-0 oc bracing: 10-11.
WEBS 1 Row at midpt 2-15, 4-15, 4-13, 7-13
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)17=1319/0-6-0(min. 0-2-11), 10=1441/0-6-0(min. 0-2-13)
Max Horz17=-309(LC 12)
Max Uplift17=-137(LC 16), 10=-219(LC 17)
MaxGrav17=1637(LC 39), 10=1709(LC 39)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-18=-1559/218, 18-19=-1462/222, 19-20=-1449/225, 2-20=-1319/246, 2-21=-1535/310,
3-21=-1356/347, 3-22=-1131/328, 4-22=-1131/328, 4-5=-1238/349, 5-23=-1485/342,
6-23=-1529/314, 6-7=-1697/297, 7-24=-1865/285, 24-25=-2087/258, 8-25=-2104/234,
1-17=-1577/244, 8-10=-1635/340
BOT CHORD 16-17=-275/320, 15-16=-153/1217, 14-15=-73/1196, 13-14=-73/1196, 12-13=-62/1665,
11-12=-62/1665, 10-11=-59/340
WEBS 2-16=-475/132, 3-15=-67/434, 4-15=-367/193, 5-13=-38/463, 7-13=-599/261,
1-16=-124/1316, 8-11=-96/1540
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 12-3-5,Exterior(2) 12-3-5 to 25-3-10,
Interior(1) 25-3-10 to 38-6-12zone;cantileverright exposed ; end verticalright exposed;C-C formembers and forces&MWFRS for
reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates areMT20 plates unless otherwiseindicated.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
17=137, 10=219.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
Continued 1. on page 2
10-11-0
5-0-0
15-11-0
5-0-0
20-10-0
4-11-0
-1-2-12
1-2-12
5-11-0
5-11-0
10-11-0
5-0-0
15-11-0
5-0-0
20-10-0
4-11-0
23-0-12
2-2-12
0-7-13
7-11-2
1-3-13
8.0012
PlateOffsets(X,Y)-- [2:0-2-12,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.74
0.67
0.60
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.05
-0.12
0.04
(loc)
12
12
8
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 253 lb FT= 20%
GRIP
197/144
LUMBER-
TOP CHORD2x6SPF No.2
BOT CHORD2x6SPF No.2
WEBS 2x4SPFStud*Except*
W5: 2x6SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-6-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size)2=5054/0-6-0(min. 0-4-12), 8=2544/0-6-0(min. 0-2-4)
Max Horz2=234(LC 15)
Max Uplift2=-1151(LC 16), 8=-558(LC 17)
MaxGrav2=6023(LC 30), 8=2881(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-2=-65/407, 2-16=-7090/1301, 3-16=-6277/1173, 3-17=-4251/838, 17-18=-3473/715,
4-18=-3294/688, 4-19=-3169/685, 19-20=-3306/680, 5-20=-3388/680, 5-21=-3332/588,
6-21=-3362/582, 6-8=-2788/583
BOT CHORD 2-12=-995/5365, 11-12=-995/5365, 10-11=-995/5365, 9-10=-396/2689, 8-9=-32/444
WEBS 3-12=0/263, 3-10=-3261/748, 4-10=-400/2068, 5-9=-456/148, 6-9=-371/2403
NOTES-
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x6- 2 rowsstaggered at 0-9-0 oc.
Bottomchordsconnected as follows: 2x6- 2 rowsstaggered at 0-9-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3) Unbalancedroofliveloads have been considered for this design.
4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 10-11-0,Exterior(2) 10-11-0 to 13-11-0
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
5)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
6) Unbalancedsnowloads have been considered for this design.
7)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
2=1151, 8=558.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S) Standard
Continued on page 2
30
3x4
3x4
2x4
3x4
3x4
3x4
20-10-0
20-10-0
-1-2-12
1-2-12
10-11-0
10-11-0
20-10-0
9-11-0
23-0-12
2-2-12
0-7-13
7-11-2
1-3-13
8.0012
PlateOffsets(X,Y)-- [2:0-2-2,0-0-1], [9:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.49
0.10
0.16
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.05
-0.10
0.00
(loc)
16
16
17
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 108 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
SLIDER Left 2x4SPFStud 1-6-2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 20-10-0.
(lb)-Max Horz2=236(LC 15)
Max UpliftAll uplift 100 lb orless at joint(s) 17, 2, 23, 24, 25, 27, 28, 20, 19 except 21=-102(LC 17),
18=-218(LC 22)
MaxGravAllreactions 250 lb orless at joint(s) 2, 23, 24, 25, 27, 28, 22, 21, 20, 19, 18 except 17=447(LC
22)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 15-17=-426/189
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-C Corner(3)-1-2-12 to 1-11-0,Exterior(2) 1-11-0 to 10-11-0, Corner(3) 10-11-0 to
13-11-0zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS for
reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
7)All plates are 1.5x4MT20 unless otherwiseindicated.
8)Gablerequirescontinuous bottomchord bearing.
9)Gablestudsspaced at 2-0-0 oc.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 17, 2, 23, 24, 25,
27, 28, 20, 19 except(jt=lb) 21=102, 18=218.
12)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S) Standard
5-7-4
5-7-4
10-11-0
5-3-12
16-2-12
5-3-12
20-10-0
4-7-4
-1-2-12
1-2-12
5-7-4
5-7-4
10-11-0
5-3-12
16-2-12
5-3-12
20-10-0
4-7-4
23-0-12
2-2-12
0-7-13
7-11-2
1-3-13
8.0012
PlateOffsets(X,Y)-- [2:0-2-2,0-0-1], [7:0-3-0,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.49
0.31
0.38
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.03
-0.09
0.03
(loc)
11-13
11-13
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 98 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W3: 2x4 HF/SPF No.2
SLIDER Left 2x4SPFStud 1-6-0
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-2-5 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing,Except:
6-0-0 oc bracing: 9-10.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)2=790/0-6-0(min. 0-1-8), 9=858/0-5-3(min. 0-1-10)
Max Horz2=238(LC 15)
Max Uplift2=-137(LC 16), 9=-156(LC 17)
MaxGrav2=895(LC 2), 9=976(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-3=-461/0, 3-18=-1094/131, 4-18=-959/159, 4-19=-772/167, 19-20=-709/170,
5-20=-707/187, 5-21=-706/183, 21-22=-709/166, 6-22=-771/163, 6-23=-806/137,
7-23=-934/111, 7-9=-934/240
BOT CHORD 2-13=-137/922, 12-13=-137/922, 11-12=-137/922, 10-11=-6/717
WEBS 4-11=-423/199, 5-11=-74/528, 6-11=-275/160, 7-10=-68/764
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-1-2-12 to 1-9-4,Interior(1) 1-9-4 to 10-11-0,Exterior(2) 10-11-0 to 13-11-0
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
2=137, 9=156.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
5x6 3x4
3x4
3x5
3x4 3x6
3x4
25-7-0
25-7-0
10-9-12
10-9-12
25-7-0
14-9-4
11-6-0
1-7-13
11-6-0
8.0012
PlateOffsets(X,Y)-- [7:0-2-0,0-2-3]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.58
0.34
0.21
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.02
(loc)
-
-
17
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 193 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W1: 2x4SPF 1650F 1.5E
OTHERS 2x4 HF/SPF No.2 *Except*
ST5,ST6,ST7,ST8: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 7-7-5 oc bracing.
WEBS 1 Row at midpt 1-31, 2-30, 3-29, 4-28, 5-27, 6-25, 8-24,
9-23
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 25-7-0.
(lb)-Max Horz31=-444(LC 12)
Max UpliftAll uplift 100 lb orless at joint(s) 31, 30, 29, 28, 27, 25, 24, 23, 22,
21, 20, 19 except 17=-302(LC 15), 18=-331(LC 12)
MaxGravAllreactions 250 lb orless at joint(s) 31, 30, 29, 28, 27, 25, 24, 23,
22, 21, 20, 19 except 17=521(LC 12), 18=323(LC 15)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 9-10=-261/280, 10-11=-312/332, 11-12=-324/321, 12-13=-385/383, 13-34=-440/434,
14-34=-447/414, 14-15=-511/488, 15-16=-564/533, 16-17=-764/694
BOT CHORD 30-31=-493/534, 29-30=-493/534, 28-29=-493/534, 27-28=-493/534, 26-27=-493/534,
25-26=-493/534, 24-25=-493/534, 23-24=-493/534, 22-23=-493/534, 21-22=-493/534,
20-21=-493/534, 19-20=-493/534, 18-19=-493/534
WEBS 16-18=-637/685
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-C Corner(3) 0-1-12 to 3-1-12,Exterior(2) 3-1-12 to 10-9-12, Corner(3) 10-9-12 to 13-11-0
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)All plates are 1.5x4MT20 unless otherwiseindicated.
7)Gablerequirescontinuous bottomchord bearing.
8)Truss to be fullysheathed from one face orsecurely braced againstlateralmovement(i.e. diagonalweb).
9)Gablestudsspaced at 2-0-0 oc.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
Continued on page 2
3x4
3x5
3x4 3x6
3x4
25-7-0
25-7-0
10-9-12
10-9-12
25-7-0
14-9-4
26-9-12
1-2-12
11-6-0
1-7-13
11-6-0
8.0012
PlateOffsets(X,Y)-- [7:0-2-0,0-2-3]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.16
0.08
0.21
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.01
0.02
(loc)
17
17
18
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 195 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W1: 2x4 HF/SPF No.2
OTHERS 2x4 HF/SPF No.2 *Except*
ST5,ST6,ST7,ST8: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 9-3-0 oc bracing,Except:
6-0-0 oc bracing: 18-19.
WEBS 1 Row at midpt 1-32, 2-31, 3-30, 4-29, 5-28, 6-26, 8-25,
9-24
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 25-7-0.
(lb)-Max Horz32=-411(LC 17)
Max UpliftAll uplift 100 lb orless at joint(s) 32, 31, 30, 29, 28, 26, 25, 24, 23,
22, 21, 20 except 18=-160(LC 15), 19=-432(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 32, 31, 30, 29, 28, 26, 25, 24,
23, 22, 21, 20 except 18=582(LC 17), 19=254(LC 15)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 12-13=-273/220, 13-34=-331/271, 14-34=-337/259, 14-15=-406/326, 15-16=-455/376,
16-18=-568/444
BOT CHORD 31-32=-380/458, 30-31=-380/458, 29-30=-380/458, 28-29=-380/458, 27-28=-380/458,
26-27=-380/458, 25-26=-380/458, 24-25=-380/458, 23-24=-380/458, 22-23=-380/458,
21-22=-380/458, 20-21=-380/458, 19-20=-380/458
WEBS 16-19=-465/569
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-C Corner(3) 0-1-12 to 3-1-12,Exterior(2) 3-1-12 to 10-9-12, Corner(3) 10-9-12 to 13-11-0
zone;cantileverright exposed ; end verticalright exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber
DOL=1.60 plate grip DOL=1.60
2)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Provide adequate drainage to preventwater ponding.
7)All plates are 1.5x4MT20 unless otherwiseindicated.
8)Gablerequirescontinuous bottomchord bearing.
Continued 9)Truss to on be page fullysheathed 2 from one face orsecurely braced againstlateralmovement(i.e. diagonalweb).
3x5
4x4
3x4
4x4
5-6-10
5-6-10
10-9-12
5-3-2
18-3-4
7-5-9
25-7-0
7-3-12
5-6-10
5-6-10
10-9-12
5-3-2
18-3-4
7-5-9
25-7-0
7-3-12
11-6-0
1-7-13
11-6-0
8.0012
PlateOffsets(X,Y)-- [3:0-3-12,0-2-0], [6:0-1-4,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.94
0.50
0.66
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.19
0.03
(loc)
7-8
8-9
7
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 156 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W5,W7,W6: 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-2-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 9-4-8 oc bracing.
WEBS 1 Row at midpt 1-12, 2-11, 3-11, 5-9
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)12=979/Mechanical, 7=918/Mechanical
Max Horz12=-379(LC 17)
Max Uplift12=-195(LC 12), 7=-74(LC 17)
MaxGrav12=1160(LC 34), 7=1116(LC 35)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-12=-1110/268, 1-13=-442/98, 2-13=-442/98, 2-14=-442/98, 14-15=-442/98,
3-15=-442/98, 3-16=-686/124, 16-17=-720/104, 4-17=-735/103, 4-5=-951/79,
5-18=-1130/92, 18-19=-1274/65, 6-19=-1359/65, 6-7=-1050/110
BOT CHORD 11-12=-354/379, 10-11=0/604, 9-10=0/604, 8-9=0/1061
WEBS 1-11=-223/1004, 2-11=-581/192, 3-11=-559/199, 3-9=-101/527, 5-9=-622/271,
6-8=0/984
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 10-9-12,Exterior(2) 10-9-12 to
13-9-12zone;cantileverright exposed ; end verticalright exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
3) Unbalancedsnowloads have been considered for this design.
4)Provide adequate drainage to preventwater ponding.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 7 except(jt=lb)
12=195.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
1
2
3
4 5 6
7
8
9
17 16 15 14
13 12 11
10
42
43
44
45
46 47 48 49 50 51
4x8
4x8
3x4 3x4
3x6
3x4 3x4
3x8
3x4
3x6
3x4
5x6
2x4
5x6
3x4
3x4
5-4-0
5-4-0
9-11-8
4-7-8
12-9-0
2-9-8
18-8-8
5-11-8
23-4-0
4-7-8
28-8-0
5-4-0
-0-10-12
0-10-12
5-4-0
5-4-0
9-11-8
4-7-8
12-9-0
2-9-8
18-8-8
5-11-8
23-4-0
4-7-8
28-8-0
5-4-0
29-3-12
0-7-12
1-9-8
11-9-0
1-9-8
11-9-0
12.0012
PlateOffsets(X,Y)-- [2:0-2-12,0-1-8], [4:0-6-4,0-1-12], [6:0-6-4,0-1-12], [8:0-2-12,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.70
0.41
0.88
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.04
-0.09
0.01
(loc)
16-17
16-17
10
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 284 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W3,W1,W2: 2x4SPFStud
OTHERS 2x4SPFStud*Except*
ST9,ST5,ST12: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 9-5-5 oc bracing.
WEBS 1 Row at midpt 3-15, 4-14, 5-14, 6-14, 7-12
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)17=701/0-6-0(min. 0-1-8), 14=1539/0-6-0(min. 0-2-13), 10=564/0-4-0(min. 0-1-8)
Max Horz17=343(LC 11)
Max Uplift17=-234(LC 12), 14=-443(LC 9), 10=-115(LC 8)
MaxGrav17=904(LC 35), 14=1701(LC 35), 10=785(LC 35)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-42=-736/177, 42-43=-707/161, 3-43=-630/193, 3-4=-357/212, 6-7=-461/199,
7-45=-589/135, 8-45=-717/104, 2-17=-752/193, 8-10=-735/102
BOT CHORD 17-46=-355/375, 46-47=-355/375, 16-47=-355/375, 16-48=-257/514, 48-49=-257/514,
15-49=-257/514, 15-50=-212/276, 50-51=-212/276, 14-51=-212/276, 11-12=-50/416
WEBS 3-16=-104/332, 3-15=-577/345, 4-15=-348/701, 4-14=-845/296, 5-14=-589/167,
6-14=-589/198, 6-12=-180/424, 7-12=-399/257, 2-16=-74/354, 8-11=-51/334
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; porchright exposed;
Lumber DOL=1.60 plate grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0 Rainsurcharge applied to all
exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
7)Provide adequate drainage to preventwater ponding.
8)All plates are 1.5x4MT20 unless otherwiseindicated.
9)Gablestudsspaced at 2-0-0 oc.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
17=234, 14=443, 10=115.
12)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
Continued 1. on page 2
3x6
4x6 4x6
3x10
8x8 8x8
4x8
1.5x4
3x4
3x6
3x4
2x4
4-10-15
4-10-15
9-11-8
5-0-9
12-9-0
2-9-8
18-8-8
5-11-8
23-9-1
5-0-9
28-8-0
4-10-15
4-10-15
4-10-15
9-11-8
5-0-9
12-9-0
2-9-8
18-8-8
5-11-8
23-9-1
5-0-9
28-8-0
4-10-15
1-9-8
11-9-0
1-9-8
11-9-0
12.0012
PlateOffsets(X,Y)-- [3:0-6-4,0-1-12], [5:0-6-4,0-1-12], [13:0-3-8,0-4-8], [14:0-3-8,0-4-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.36
0.84
0.83
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.08
-0.17
0.01
(loc)
13-14
13-14
8
l/defl
>999
>889
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 414 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x6SPF No.2
WEBS 2x4 HF/SPF No.2 *Except*
W3,W2,W9,W8: 2x4SPFStud,W1: 2x6SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-12, 5-12
REACTIONS. (lb/size)15=3435/0-6-0(min. 0-2-14), 12=4656/0-6-0(min. 0-3-12), 8=574/0-4-0(min. 0-1-8)
Max Horz15=-316(LC 53)
Max Uplift15=-252(LC 12), 12=-521(LC 9), 8=-104(LC 8)
MaxGrav15=3643(LC 34), 12=4810(LC 34), 8=798(LC 34)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 1-16=-3164/221, 2-16=-2910/249, 2-17=-1325/173, 3-17=-1126/212, 5-20=-322/169,
6-20=-530/130, 6-21=-526/123, 7-21=-782/95, 1-15=-2941/224, 7-8=-757/89
BOT CHORD 15-22=-323/470, 22-23=-323/470, 14-23=-323/470, 14-24=-330/2165, 24-25=-330/2165,
13-25=-330/2165, 13-26=-232/839, 12-26=-232/839, 11-12=-105/259, 10-11=-105/259,
9-10=-56/484
WEBS 2-14=-171/2534, 2-13=-2159/391, 3-13=-409/3784, 3-12=-3348/374, 4-12=-603/167,
5-12=-449/289, 5-10=-223/307, 6-10=-404/254, 1-14=-116/1967, 7-9=-51/449
NOTES-
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-9-0 oc, 2x6- 2 rowsstaggered at 0-9-0 oc.
Bottomchordsconnected as follows: 2x6- 2 rowsstaggered at 0-7-0 oc.
Websconnected as follows: 2x4- 1 row at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3) Unbalancedroofliveloads have been considered for this design.
4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; porchright exposed;
Lumber DOL=1.60 plate grip DOL=1.60
5)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0 Rainsurcharge applied to all
exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
6) Unbalancedsnowloads have been considered for this design.
7)Provide adequate drainage to preventwater ponding.
8)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) except(jt=lb)
15=252, 12=521, 8=104.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
Continued on page 2
3x4 3x4
16-10-0
16-10-0
-0-7-12
0-7-12
8-5-0
8-5-0
16-10-0
8-5-0
17-5-12
0-7-12
1-9-8
10-2-8
1-9-8
12.0012
PlateOffsets(X,Y)-- [7:0-3-7,Edge], [14:Edge,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-R
0.31
0.18
0.21
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
13
13
14
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 105 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud*Except*
ST4: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 6-19, 8-18
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 16-10-0.
(lb)-Max Horz24=297(LC 15)
Max UpliftAll uplift 100 lb orless at joint(s) 21, 16 except 24=-253(LC 14),
14=-236(LC 15), 20=-182(LC 16), 23=-309(LC 16), 17=-182(LC 17), 15=-304(LC
17)
MaxGravAllreactions 250 lb orless at joint(s) 19, 20, 21, 18, 17, 16 except
24=327(LC 13), 14=311(LC 12), 23=347(LC 14), 15=335(LC 15)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 5-25=-261/335, 6-25=-239/340, 8-26=-239/340, 9-26=-261/335
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-C Corner(3)-0-7-12 to 2-4-4,Exterior(2) 2-4-4 to 8-5-0, Corner(3) 8-5-0 to 11-5-0zone;
cantileverleft and right exposed ; end verticalleft and right exposed; porchleft and right exposed;C-C formembers and forces &
MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
7)All plates are 1.5x4MT20 unless otherwiseindicated.
8)Gablerequirescontinuous bottomchord bearing.
9)Truss to be fullysheathed from one face orsecurely braced againstlateralmovement(i.e. diagonalweb).
10)Gablestudsspaced at 2-0-0 oc.
11)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
12)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 21, 16 except
(jt=lb) 24=253, 14=236, 20=182, 23=309, 17=182, 15=304.
13)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S) Standard
7-9-0
16-2-0
8-5-0
3-5-11
3-5-11
7-9-0
4-3-5
12-0-5
4-3-5
16-2-0
4-1-11
16-9-12
0-7-12
2-5-8
10-2-8
1-9-8
12.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.31
0.53
0.45
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.21
-0.28
0.01
(loc)
7-8
7-8
7
l/defl
>927
>690
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 92 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud*Except*
W4: 2x4 HF/SPF No.2
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-8
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)10=561/0-6-0(min. 0-1-8), 7=603/0-4-0(min. 0-1-8)
Max Horz10=-262(LC 12)
Max Uplift10=-86(LC 17), 7=-77(LC 16)
MaxGrav10=634(LC 2), 7=684(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-11=-484/462, 11-12=-445/477, 3-12=-439/495, 3-13=-434/486, 13-14=-445/469,
4-14=-487/461, 4-15=-191/282, 5-15=-240/264, 5-7=-278/266
BOT CHORD 9-10=-194/372, 8-9=-194/372, 7-8=-194/341
WEBS 3-8=-566/415, 2-10=-542/306, 4-7=-486/164
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-4-10,Interior(1) 3-4-10 to 7-9-0,Exterior(2) 7-9-0 to 10-9-0
zone;cantileverright exposed ; end verticalright exposed; porchleft and right exposed;C-C formembers and forces&MWFRS for
reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 10, 7.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.37
0.20
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.02
0.04
0.00
(loc)
5
5
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 28 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)2=201/9-6-11(min. 0-1-8), 4=201/9-6-11(min. 0-1-8), 6=342/9-6-11(min. 0-1-8)
Max Horz2=-40(LC 17)
Max Uplift2=-66(LC 16), 4=-73(LC 17), 6=-10(LC 16)
MaxGrav2=230(LC 2), 4=230(LC 2), 6=382(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 3-6=-263/123
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-7 to 3-5-7,Interior(1) 3-5-7 to 5-10-10,Exterior(2) 5-10-10 to 8-10-10
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Gablerequirescontinuous bottomchord bearing.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 4, 6.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S) Standard
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.37
0.16
0.05
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.02
0.00
(loc)
1
1
5
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 21 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)5=47/6-10-9(min. 0-1-8), 2=196/6-10-9(min. 0-1-8), 6=267/6-10-9(min. 0-1-8)
Max Horz2=56(LC 13)
Max Uplift5=-33(LC 17), 2=-57(LC 16), 6=-15(LC 16)
MaxGrav5=56(LC 2), 2=224(LC 34), 6=298(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-5-7 to 3-5-7,Interior(1) 3-5-7 to 5-10-10,Exterior(2) 5-10-10 to 7-10-2
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Gablerequirescontinuous bottomchord bearing.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 2, 6.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S) Standard
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.12
0.05
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.01
0.00
(loc)
1
1
5
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 64 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
REACTIONS. (lb/size)5=47/6-10-4(min. 0-1-8), 2=199/6-10-4(min. 0-1-8), 6=266/6-10-4(min. 0-1-8)
Max Horz2=56(LC 13)
Max Uplift5=-33(LC 17), 2=-59(LC 16), 6=-15(LC 16)
MaxGrav5=56(LC 2), 2=228(LC 34), 6=296(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) 3-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-9-0 oc.
Bottomchordsconnected as follows: 2x4- 1 row at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3) Unbalancedroofliveloads have been considered for this design.
4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-4-14 to 3-4-14,Interior(1) 3-4-14 to 5-10-10,Exterior(2) 5-10-10 to 7-10-2
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
5)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
6) Unbalancedsnowloads have been considered for this design.
7)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
8)Gablerequirescontinuous bottomchord bearing.
9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 5, 2, 6.
11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
12)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S) Standard
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.21
0.09
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.02
0.00
(loc)
4
4
3
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 19 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)6=37/5-3-10(min. 0-1-8), 3=148/5-3-10(min. 0-1-8), 5=204/5-3-10(min. 0-1-8)
Max Horz6=-89(LC 14)
Max Uplift6=-30(LC 16), 3=-38(LC 17), 5=-6(LC 17)
MaxGrav6=59(LC 30), 3=169(LC 2), 5=241(LC 31)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 4-8-0,Interior(1) 4-8-0 to 5-9-6zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Gablerequirescontinuous bottomchord bearing.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 6, 3, 5.
9)Beveled plate orshimrequired to provide full bearingsurfacewith trusschord at joint(s) 3.
10)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
LOADCASE(S) Standard
PlateOffsets(X,Y)-- [4:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.08
0.05
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
7
7
6
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 24 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 7-3-3.
(lb)-Max Horz2=-72(LC 14)
Max UpliftAll uplift 100 lb orless at joint(s) 9, 8
MaxGravAllreactions 250 lb orless at joint(s) 2, 6, 9, 8
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-3-5 to 3-4-11,Interior(1) 3-4-11 to 4-4-12,Exterior(2) 4-4-12 to 7-4-12
zone;cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
7)Gablerequirescontinuous bottomchord bearing.
8)Gablestudsspaced at 2-0-0 oc.
9)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
10)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 9, 8.
11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
12)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S) Standard
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.21
0.12
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.02
0.00
(loc)
5
5
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 23 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)2=163/7-3-3(min. 0-1-8), 4=163/7-3-3(min. 0-1-8), 6=237/7-3-3(min. 0-1-8)
Max Horz2=72(LC 15)
Max Uplift2=-52(LC 16), 4=-62(LC 17)
MaxGrav2=188(LC 2), 4=188(LC 2), 6=263(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-3-5 to 3-3-5,Interior(1) 3-3-5 to 4-4-12,Exterior(2) 4-4-12 to 7-4-12zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Gablerequirescontinuous bottomchord bearing.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 4.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
10)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S) Standard
8.0012
PlateOffsets(X,Y)-- [3:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.11
0.04
0.05
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
7
8
7
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 43 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 10-0-13.
(lb)-Max Horz13=-171(LC 12)
Max UpliftAll uplift 100 lb orless at joint(s) 13, 7, 12, 11, 10, 9
MaxGravAllreactions 250 lb orless at joint(s) 13, 7, 12, 11, 10, 9
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 5-11-0,Interior(1) 5-11-0 to 10-6-6zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
7)All plates are 1.5x4MT20 unless otherwiseindicated.
8)Gablerequirescontinuous bottomchord bearing.
9)Gablestudsspaced at 2-0-0 oc.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11)Bearing at joint(s) 13 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
12)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 13, 7, 12, 11, 10,
9.
13)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
14)Gap betweeninside of top chord bearing and first diagonal orverticalwebshall not exceed 0.500in.
LOADCASE(S) Standard
0-1-10
0-1-6
8.0012
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.19
0.09
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
5
5
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 37 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 10-0-10.
(lb)-Max Horz8=-171(LC 12)
Max UpliftAll uplift 100 lb orless at joint(s) 8, 4, 7 except 6=-163(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 8, 4 except 6=376(LC 31), 7=268(LC 31)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 3-6=-310/212
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 5-11-0,Interior(1) 5-11-0 to 10-6-6zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
4) Unbalancedsnowloads have been considered for this design.
5)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
6)Gablerequirescontinuous bottomchord bearing.
7)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
8)Bearing at joint(s) 8 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
9)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 8, 4, 7 except
(jt=lb) 6=163.
10)Beveled plate orshimrequired to provide full bearingsurfacewith trusschord at joint(s) 4.
11)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
12)Gap betweeninside of top chord bearing and first diagonal orverticalwebshall not exceed 0.500in.
LOADCASE(S) Standard
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.06
0.03
0.04
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
0.00
(loc)
8
8
8
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 31 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. All bearings 7-7-6.
(lb)-Max Horz2=109(LC 15)
Max UpliftAll uplift 100 lb orless at joint(s) 2, 8, 12, 11 except 13=-118(LC 16), 10=-119(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 2, 8, 12, 13, 11, 10
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-2-10 to 3-4-8,Interior(1) 3-4-8 to 4-4-8,Exterior(2) 4-4-8 to 7-4-8zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
3)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
4)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
5) Unbalancedsnowloads have been considered for this design.
6)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
7)All plates are 1.5x4MT20 unless otherwiseindicated.
8)Gablerequirescontinuous bottomchord bearing.
9)Gablestudsspaced at 2-0-0 oc.
10)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
11)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 100 lb uplift at joint(s) 2, 8, 12, 11
except(jt=lb) 13=118, 10=119.
12)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
13)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S) Standard
12.0012
PlateOffsets(X,Y)-- [2:0-2-6,0-1-0], [4:0-2-0,Edge], [6:0-2-6,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.06
0.03
0.03
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
0.00
0.00
(loc)
7
7
6
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 59 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
OTHERS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
REACTIONS. All bearings 7-7-6.
(lb)-Max Horz2=-109(LC 14)
Max UpliftAll uplift 100 lb orless at joint(s) except 9=-166(LC 16), 8=-165(LC 17)
MaxGravAllreactions 250 lb orless at joint(s) 2, 6 except 9=258(LC 30), 8=256(LC 31)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
WEBS 3-9=-253/205, 5-8=-254/206
NOTES-
1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Topchordsconnected as follows: 2x4- 1 row at 0-9-0 oc.
Bottomchordsconnected as follows: 2x4- 1 row at 0-9-0 oc.
2)Allloads areconsidered equally applied to all plies, exceptif noted as front(F) or back(B) facein the LOAD CASE(S)section.Ply to
plyconnections have been provided to distribute onlyloads noted as(F) or(B), unless otherwiseindicated.
3) Unbalancedroofliveloads have been considered for this design.
4)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-2-10 to 3-4-8,Interior(1) 3-4-8 to 4-4-8,Exterior(2) 4-4-8 to 7-4-8zone;
cantileverleft and right exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown;
Lumber DOL=1.60 plate grip DOL=1.60
5)Truss designed forwindloadsin the plane of the truss only.Forstuds exposed to wind(normal to the face),seeStandardIndustry
GableEnd Details as applicable, orconsult qualified building designer as perANSI/TPI 1.
6)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
7) Unbalancedsnowloads have been considered for this design.
8)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
9)Gablerequirescontinuous bottomchord bearing.
10)Gablestudsspaced at 2-0-0 oc.
11)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
12)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 166 lb uplift at joint 9 and 165 lb uplift
atjoint 8.
13)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI
1.
14)SeeStandardIndustryPiggybackTruss Connection Detail for Connection to base truss as applicable, orconsult qualified building
designer.
LOADCASE(S) Standard
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.15
0.08
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.00
-0.01
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 8 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-4-8 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)5=142/0-6-0(min. 0-1-8), 3=44/Mechanical, 4=20/Mechanical
Max Horz5=55(LC 13)
Max Uplift5=-25(LC 12), 3=-40(LC 16)
MaxGrav5=164(LC 2), 3=51(LC 2), 4=40(LC 7)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 25 lb uplift at joint 5 and 40 lb uplift at
joint 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.18
0.06
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
-0.01
-0.01
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 10 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-2-13 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)5=119/0-8-2(min. 0-1-8), 3=30/Mechanical, 4=12/Mechanical
Max Horz5=49(LC 11)
Max Uplift5=-68(LC 10), 3=-51(LC 16)
MaxGrav5=159(LC 18), 3=35(LC 2), 4=42(LC 7)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft and right exposed ; end verticalleft and right exposed; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 68 lb uplift at joint 5 and 51 lb uplift at
joint 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S) Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-51
Trapezoidal Loads(plf)
Vert: 2=-2(F=24,B=24)-to-3=-41(F=5,B=5), 5=0(F=10,B=10)-to-4=-16(F=2,B=2)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MP
0.19
0.18
0.02
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.03
-0.03
-0.05
(loc)
5-6
5-6
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 13 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-9-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)6=141/0-4-0(min. 0-1-8), 3=58/Mechanical, 4=75/Mechanical
Max Horz6=57(LC 13)
Max Uplift6=-58(LC 12), 3=-25(LC 13), 4=-33(LC 12)
MaxGrav6=174(LC 34), 3=78(LC 35), 4=85(LC 34)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1) Unbalancedroofliveloads have been considered for this design.
2)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 2-5-14,Interior(1) 2-5-14 to 3-8-4zone;cantileverleft exposed ;
endverticalleft exposed; porchleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber
DOL=1.60 plate grip DOL=1.60
3)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=20.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1, Lu=50-0-0;Min. flatroofsnowload
governs. Rainsurcharge applied to all exposedsurfaceswithslopesless than 0.500/12 in accordancewithIBC 1608.3.4.
4) Unbalancedsnowloads have been considered for this design.
5)Provide adequate drainage to preventwater ponding.
6)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
7) Refer to girder(s) for truss to trussconnections.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 58 lb uplift at joint 6, 25 lb uplift at joint 3
and 33 lb uplift at joint 4.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.18
0.17
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.03
-0.02
-0.04
(loc)
3-4
3-4
2
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 10 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-9-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)4=125/0-4-0(min. 0-1-8), 2=85/Mechanical, 3=41/Mechanical
Max Horz4=61(LC 13)
Max Uplift4=-25(LC 12), 2=-63(LC 16), 3=-23(LC 13)
MaxGrav4=142(LC 2), 2=100(LC 2), 3=68(LC 7)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 3-8-4zone;cantileverleft exposed ;
endverticalleft exposed; porchleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber
DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
5) Refer to girder(s) for truss to trussconnections.
6)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 25 lb uplift at joint 4, 63 lb uplift at joint 2
and 23 lb uplift at joint 3.
7)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.15
0.09
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.01
-0.01
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 8 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-6-7 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)5=147/0-4-0(min. 0-1-8), 3=48/Mechanical, 4=22/Mechanical
Max Horz5=57(LC 13)
Max Uplift5=-47(LC 12), 3=-43(LC 16), 4=-19(LC 13)
MaxGrav5=170(LC 2), 3=57(LC 2), 4=44(LC 7)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-12 to 2-1-4,Interior(1) 2-1-4 to 2-5-11zone;cantileverleft exposed ;
endverticalleft exposed; porchleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber
DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 47 lb uplift at joint 5, 43 lb uplift at joint 3
and 19 lb uplift at joint 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.09
0.03
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.00
(loc)
5
5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 5 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 1-1-7 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)5=116/0-4-0(min. 0-1-8), 3=1/Mechanical, 4=4/Mechanical
Max Horz5=42(LC 13)
Max Uplift5=-31(LC 12), 3=-27(LC 22), 4=-11(LC 13)
MaxGrav5=150(LC 22), 3=1(LC 2), 4=16(LC 7)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft and right exposed ; end verticalleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 31 lb uplift at joint 5, 27 lb uplift at joint 3
and 11 lb uplift at joint 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.26
0.21
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.07
-0.07
-0.06
(loc)
4-5
4-5
3
l/defl
>904
>910
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 15 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 5-2-2 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)5=161/0-5-5(min. 0-1-8), 3=99/Mechanical, 4=44/Mechanical
Max Horz5=57(LC 11)
Max Uplift5=-153(LC 10), 3=-69(LC 12), 4=-31(LC 8)
MaxGrav5=184(LC 2), 3=117(LC 2), 4=87(LC 7)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft exposed ; end verticalleft exposed; porchleft and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 153 lb uplift at joint 5, 69 lb uplift at joint
3 and 31 lb uplift at joint 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9) Hanger(s) or otherconnection device(s)shall be providedsufficient to supportconcentratedload(s) 14 lb down and 14 lb up at
1-8-1, and 15 lb down and 21 lb up at 2-7-6, and 20 lb down and 39 lb up at 3-8-2 on top chord, and 3 lb down and 15 lb up at
1-8-1, and 3 lb down and 27 lb up at 2-7-6, and 8 lb down and 33 lb up at 3-8-2 on bottomchord.The design/selection of such
connection device(s)is the responsibility of others.
10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S) Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-51
Concentrated Loads(lb)
Vert: 10=1(F) 11=0(B) 12=-1(F)
Continued on page 2
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.13
0.06
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.00
-0.01
(loc)
5
5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 6 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 1-9-7 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)5=127/0-4-0(min. 0-1-8), 3=27/Mechanical, 4=13/Mechanical
Max Horz5=49(LC 13)
Max Uplift5=-42(LC 12), 3=-31(LC 16), 4=-18(LC 13)
MaxGrav5=148(LC 2), 3=32(LC 2), 4=30(LC 7)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)zone;cantileverleft exposed ; end verticalleft exposed; porchleft and right
exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 42 lb uplift at joint 5, 31 lb uplift at joint 3
and 18 lb uplift at joint 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.15
0.09
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.00
-0.01
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 8 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-6-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)5=146/0-4-0(min. 0-1-8), 3=47/Mechanical, 4=22/Mechanical
Max Horz5=57(LC 13)
Max Uplift5=-47(LC 12), 3=-42(LC 16), 4=-19(LC 13)
MaxGrav5=168(LC 2), 3=55(LC 2), 4=43(LC 7)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-0-10-12 to 2-1-4,Interior(1) 2-1-4 to 2-5-4zone;cantileverleft exposed ;
endverticalleft exposed; porchleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber
DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 47 lb uplift at joint 5, 42 lb uplift at joint 3
and 19 lb uplift at joint 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.18
0.07
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.01
-0.01
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 11 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 3-4-15 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)5=122/0-5-5(min. 0-1-8), 3=35/Mechanical, 4=15/Mechanical
Max Horz5=50(LC 11)
Max Uplift5=-101(LC 10), 3=-54(LC 10), 4=-22(LC 10)
MaxGrav5=160(LC 18), 3=41(LC 2), 4=46(LC 7)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft exposed ; end verticalleft exposed; porchleft and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 101 lb uplift at joint 5, 54 lb uplift at joint
3 and 22 lb uplift at joint 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S) Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-51
Trapezoidal Loads(plf)
Vert: 2=-2(F=24,B=24)-to-3=-43(F=4,B=4), 5=0(F=10,B=10)-to-4=-17(F=1,B=1)
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.20
0.12
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.02
0.00
(loc)
3-4
3-4
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 13 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)4=131/0-6-0(min. 0-1-8), 3=131/0-1-8(min. 0-1-8)
Max Horz4=99(LC 13)
Max Uplift4=-27(LC 12), 3=-40(LC 13)
MaxGrav4=148(LC 2), 3=148(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2) 0-1-12 to 3-1-12,Interior(1) 3-1-12 to 3-10-4zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
5)Bearing at joint(s) 3 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
6)Providemechanicalconnection(by others) of truss to bearing plate at joint(s) 3.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 27 lb uplift at joint 4 and 40 lb uplift at
joint 3.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
BCDL
20.0
10.0
0.0
10.0
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.32
0.12
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.02
-0.00
(loc)
4-5
4-5
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 15 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 4-0-0 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 6-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)5=264/0-6-0(min. 0-1-8), 4=103/0-1-8(min. 0-1-8)
Max Horz5=114(LC 13)
Max Uplift5=-129(LC 12), 4=-38(LC 13)
MaxGrav5=305(LC 2), 4=115(LC 2)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-5=-265/219
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone and C-CExterior(2)-1-10-12 to 1-1-4,Interior(1) 1-1-4 to 3-10-4zone;cantileverleft and right
exposed ; end verticalleft and right exposed;C-C formembers and forces&MWFRS forreactionsshown; Lumber DOL=1.60 plate
grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6)Bearing at joint(s) 4 considers parallel to grainvalue usingANSI/TPI 1 angle to grain formula.Building designershouldverify
capacity of bearingsurface.
7)Providemechanicalconnection(by others) of truss to bearing plate at joint(s) 4.
8)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 129 lb uplift at joint 5 and 38 lb uplift at
joint 4.
9)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
LOADCASE(S) Standard
SPACING-
PlateGrip DOL
Lumber DOL
RepStressIncr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MR
0.88
0.22
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
0.01
-0.07
(loc)
4-5
4-5
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 12 lb FT= 20%
GRIP
185/144
LUMBER-
TOP CHORD2x4 HF/SPF No.2
BOT CHORD2x4 HF/SPF No.2
WEBS 2x4SPFStud
BRACING-
TOP CHORD Structuralwoodsheathing directly applied or 2-9-5 oc purlins,
except end verticals.
BOT CHORD Rigidceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and requiredcross bracing
beinstalled during truss erection,in accordancewithStabilizer
Installation guide.
REACTIONS. (lb/size)5=262/1-7-0(min. 0-1-8), 3=-34/Mechanical, 4=-10/Mechanical
Max Horz5=65(LC 11)
Max Uplift5=-179(LC 8), 3=-91(LC 18), 4=-25(LC 18)
MaxGrav5=397(LC 18), 3=29(LC 8), 4=27(LC 7)
FORCES. (lb)-Max. Comp./Max.Ten.-All forces 250 (lb) orless exceptwhenshown.
TOP CHORD 2-5=-354/176
NOTES-
1)Wind:ASCE 7-10;Vult=115mph(3-second gust)Vasd=91mph;TCDL=6.0psf;BCDL=6.0psf; h=25ft; Cat. II;Exp C; enclosed;
MWFRS(envelope) gable end zone;cantileverleft exposed ; end verticalleft exposed; Lumber DOL=1.60 plate grip DOL=1.60
2)TCLL:ASCE 7-10;Pr=20.0 psf(roofliveload: Lumber DOL=1.15Plate DOL=1.15);Pg=20.0 psf(groundsnow);Pf=15.4 psf(flat
roofsnow: Lumber DOL=1.15Plate DOL=1.15); CategoryII;Exp C; PartiallyExp.; Ct=1.1
3) Unbalancedsnowloads have been considered for this design.
4)This truss has been designed for greater of minroofliveload of 12.0 psf or 2.00 times flatroofload of 15.4 psf on overhangs
non-concurrentwith otherliveloads.
5)This truss has been designed for a 10.0 psf bottomchordliveload nonconcurrentwith any otherliveloads.
6) Refer to girder(s) for truss to trussconnections.
7)Providemechanicalconnection(by others) of truss to bearing platecapable of withstanding 179 lb uplift at joint 5, 91 lb uplift at joint
3 and 25 lb uplift at joint 4.
8)This trussis designedin accordancewith the 2012 InternationalBuilding Code section 2306.1 and referencedstandardANSI/TPI 1.
9)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F) or back(B).
LOADCASE(S) Standard
1) Dead +Snow(balanced): LumberIncrease=1.15,PlateIncrease=1.15
Uniform Loads(plf)
Vert: 1-2=-51
Trapezoidal Loads(plf)
Vert: 2=-2(F=24,B=24)-to-3=-36(F=7,B=7), 5=0(F=10,B=10)-to-4=-14(F=3,B=3)