Loading...
HomeMy WebLinkAboutA004THERMO-PLY SHEATHING 24" POLY FLASHING, TYPICAL OVERLAP THERMO-PLY SHEATHING 2" - TYPICAL 2x BLOCKING BETWEEN STUDS - T/BLK'G TO ALIGN WITH T/ TOP PLATE AT ADJACENT WALLS. APPROVED ANCHOR THRU BOTH SHEETS OF THERMO-PLY @ 3"o.c TYP. - ANCHORS MUST PENETRATE BLOCKING 1" MINIMUM. HORIZONTAL SIDING OR BRICK VENEER - REFER TO ELEVATIONS THERMO-PLY SHEATHING BLOCKING @ BALLOON FRAME WALL SCALE: 3" = 1'-0" SECTION DETAIL - 04 FAMILY ROOM / OWNER'S SUITE SCALE:03 1/4"= 1'-0" SECT - THRU REC ROOM / BEDROOM 2 / OWNER'S BATH SCALE: 02 1/4" = 1'-0" SECT - THRU GARAGE / STUDY 3/8" = 1'-0" SEE DETAIL 04/A6.0 FOR BLOCKING @ T-PLY SEAMS ELEVATION DETAIL - FAMILY ROOM 2x6 BALLOON FRAME WALL SCALE: NOTE: DESIGNED FOR 90mph WIND SPEED 19'-10" BALLOON FRAME REAR WALL 9" 2'-8" ROUGH OPENING 19'-10" BALLOON FRAME REAR WALL 4'-7" 5'-5 3 4" 05 BASEMENT FAMILY ROOM TWO-STORY REC ROOM RETREAT OWNER'S 6'-5" 9'-1"312"6'-5" 9'-1"312"6'-918"19'-0"BASEMENT GARAGE 9'-0" 312"7'-1058" 9'-1" 9'-1"STUDY BATH / WIC OWNER'S 6'-918" 11'-278"1'-378"8" 10" - REFER TO ELEVATION FOR SIZE - REFER TO ELEVATION FOR SIZE DETAIL - GABLE RETURN SCALE: 1/2" = 1'-0" GABLE EXTENSION - 2x8 BLOCKS @ 24" o.c. ON 1x6 - REFER TO ELEVATION FOR EXTENSION FROM FRAME WALL 1x GABLE FRIEZE - w/ BARGE MOULD - REFER TO ELEVATION FOR 1x RAKE BOARD FIBERGLASS / ASPHALT SHINGLES 1x8 GUTTER BOARD - w/ ALUMINUM GUTTER 2x4 NAILER 2x4 RAFTER 2x4 RAFTER TIE PRE-ENGINEERED TRUSSES @ 24" o.c. VARIES REFER TO ELEVATION DBL. 2x4 TOP  BACK-UP / EXTENSION FROM FRAME WALL 06 10'-558" 9'-0" 2'-812" BEDROOM 2 BRICK VENEER, TYPICAL WINDOW NAILING FLANGE MUST HAVE A CONTINUOUS LAP OF 1-1/8" OVER THE SHEATHING STEEL LINTEL, TYPICAL - RE: GENERAL NOTES FOR SIZE & BEARING REQUIREMENTS WOOD HEADER - PULL 1 4" FROM FACE OF VENEER - REFER TO ELEVATION SHEET FOR MATERIAL AND EXTENSION ON EITHER SIDE OF WINDOW 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE. - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G. 3" = 1'-0" 18" MYLAR FLASHING -EXTEND 8" BEYOND EA. SIDE OF HEADER -NAIL & CAULK T/ FLASH'G TO SHEATHING, TYP. BRICK WEEPHOLES, TYPICAL -ANGLE UP FROM BTM OF SOLDIER -2'-0" o.c. & AT EA. SIDE OF OPN'G -KEEP WEEPS TO MINIMUM (3/16") 11 2" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE. - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES WINDOW HEAD w/ 4x8 WD HEAD @ MASONRY VENEER SCALE:07 7'-9" FRAME TO EDGE OF CONCRETE AT DOOR - w/ BARGE MOULD 1x6 FRIEZE BOARD PRE-ENG. TRUSSES @ 24" o.c. 3/8" HARDBOARD NOTE: 1x8 TRIM 2x4 BLK'G. @ COLUMNS 3/8" SHIMS - MATCH TO 1x4 TRIM @ BRICK 7'-103 4" AT DOOR 8" OH 112" 7'-512" PORCH DEPTH AT DOOR 5'-3" WALL BEYOND 112" NOTE: ADJUST TO GRADE FOR AESTHETIC #4 RE-BAR @ 11" o.c. - SIDE TO SIDE #4 RE-BAR @ 18" o.c. - FRONT TO BACK PURPOSES ONLY - FORM DOWN 12" MIN. - PLACED BELOW FRONT TO BACK BARS IN SLAB - PLACED ABOVE SIDE TO SIDE BARS IN SLAB 2x12 BEAM FASTEN TRUSS TO 2x12 BEAM w/ (3) 16d NAILS 2x2 BLOCKING 618" SECTION - FRONT PORCH SCALE: 3/8" = 1'-0" 7'-27 8" FRAME DIMENSION AT DOOR VENTED SOFFIT 1x8 GUTTER BD 1x10 TRIM 4 12 - RIP TO 8 3/4"w. ROUGH SAWN CEDAR 1x8's ROUGH SAWN CEDAR 1x10's 1x4 & 1x6 TRIM BLOCKING @ 24"o.c. ROUGH SAWN CEDAR 1x10's NOTE: LAY BRICK THROUGH TRUSSES TRUSS HANGER 2x4 BLK'G. FOR HANGERS NAIL AND CAULK TOP OF .40 MIL BUTYL TO THERMOPLY SHT'G. .40 MIL BUTYL FLSH'G - ON TOP OF T-PLY SHT'G & OVER FLASHING BRICK VENEER - WEEPHOLES @ 24" O.C. OVER ROOF METAL FLASHING - SET INTO BRICK & ONTO ROOF MATERIAL 08 3/4" = 1'-0"SCALE: BRICK VENEER, TYP. HARDBOARD FRIEZE - REFER TO ELEVATIONS FOR SIZES AND PROFILES 1x8 GUTTER BOARD, TYP. ALUMINUM GUTTER - REFER TO ELEVATIONS FIBERGLASS ASPHALT SHINGLES OVER 7/16" ROOF SHEATHING CULTURED STONE VENEER, TYP. - HOLD OFF T/ SHINGLES 1"± METAL FLASHING - TURN OUT 3" ABOVE GUTTER FLASHING @ STONE VENEER DETAIL - 11 DETAIL - ROOF CRICKET SCALE: 3/4" = 1'-0"09 1 1/2" = 1'-0"SCALE: SUPPORTED BY ROOF TRUSS DETAIL - BRICK VENEER 312" x 312" x 1 4" STEEL LINTEL METAL COUNTER FLASHING - SET INTO BRICK & ONTO STEP FLASHING ROOF TRUSS ICE & WATER SHIELD - 36" WIDE, 12" UP WALL & 24" ONTO ROOF - INSTALLED BEHIND & UNDER STEEL LINTEL STEP FLASHING NOTE: TRUSS MANUFACTURER TO SIZE TRUSS FOR ADDITIONAL BRICK LOADING 10 4'-03 4" TO NOSING 6'-01 4" TO NOSING 2'-6" (3) TREADS @ 10" 4'-1114" TO NOSING 11'-512" TO NOSING SECTION DETAIL - THRU STAIRS SCALE: 3/8" = 1'-0" 4'-0"12" 01 REASON FOR PLOT: PLOT DATE: Job No. Sheet No.INNEW RESIDENCE FOR: HOMESITE NO. MASTER BY: DATE: C DATE: FISCHER HOMES INDIANAPOLIS LP6602 E 75TH ST SUITE 400INDIANAPOLIS IN 46250317.348.2500FIELD SPEC HOTLINE: (859) 344-7100COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc.JOB INFO: DATE: PHONE No: HOME TYPE: PLAN NO. EXTERIOR: 12/10/2018 3:18 PM OBF-071RAFAEL & ANNYMILIA BASSO14460 PEMBERTON LANEINGLENOOKG250AHOVERBROOK FARMS CARMEL, IN 46074071 ---- ---- 2016 859.344.3115 11/30/18 CHRISTINA BISHOPGRAND ESTATE COLLECTION fieldspecchange@fischerhomes.comREVISED BY: TEAM MANAGER:PHONE No:859.426.4223SHEZYRA SISKOWICA6.0 12/21/18 Mike Sheeks