HomeMy WebLinkAboutA004THERMO-PLY SHEATHING
24" POLY FLASHING, TYPICAL
OVERLAP THERMO-PLY SHEATHING 2"
- TYPICAL
2x BLOCKING BETWEEN STUDS
- T/BLK'G TO ALIGN WITH T/ TOP
PLATE AT ADJACENT WALLS.
APPROVED ANCHOR THRU BOTH SHEETS OF
THERMO-PLY @ 3"o.c TYP.
- ANCHORS MUST PENETRATE BLOCKING 1"
MINIMUM.
HORIZONTAL SIDING OR BRICK VENEER
- REFER TO ELEVATIONS
THERMO-PLY SHEATHING
BLOCKING @ BALLOON FRAME WALL
SCALE: 3" = 1'-0"
SECTION DETAIL -
04 FAMILY ROOM / OWNER'S SUITE
SCALE:03 1/4"= 1'-0"
SECT - THRU REC ROOM /
BEDROOM 2 / OWNER'S BATH
SCALE: 02 1/4" = 1'-0"
SECT - THRU GARAGE / STUDY
3/8" = 1'-0"
SEE DETAIL 04/A6.0 FOR BLOCKING @ T-PLY SEAMS
ELEVATION DETAIL - FAMILY ROOM 2x6 BALLOON FRAME WALL
SCALE:
NOTE:
DESIGNED FOR 90mph WIND SPEED
19'-10"
BALLOON FRAME REAR WALL
9" 2'-8"
ROUGH OPENING
19'-10"
BALLOON FRAME REAR WALL
4'-7" 5'-5 3 4"
05
BASEMENT
FAMILY ROOM
TWO-STORY
REC ROOM
RETREAT
OWNER'S
6'-5" 9'-1"312"6'-5" 9'-1"312"6'-918"19'-0"BASEMENT
GARAGE
9'-0" 312"7'-1058" 9'-1" 9'-1"STUDY
BATH / WIC
OWNER'S
6'-918" 11'-278"1'-378"8" 10"
- REFER TO ELEVATION FOR SIZE
- REFER TO ELEVATION FOR SIZE
DETAIL - GABLE RETURN
SCALE: 1/2" = 1'-0"
GABLE EXTENSION
- 2x8 BLOCKS @ 24" o.c. ON 1x6
- REFER TO ELEVATION FOR
EXTENSION FROM FRAME WALL
1x GABLE FRIEZE
- w/ BARGE MOULD
- REFER TO ELEVATION FOR
1x RAKE BOARD
FIBERGLASS / ASPHALT SHINGLES
1x8 GUTTER BOARD
- w/ ALUMINUM GUTTER
2x4 NAILER
2x4 RAFTER
2x4 RAFTER TIE
PRE-ENGINEERED TRUSSES @ 24" o.c.
VARIES
REFER TO
ELEVATION
DBL. 2x4 TOP
BACK-UP / EXTENSION FROM FRAME WALL
06 10'-558" 9'-0" 2'-812" BEDROOM 2
BRICK VENEER, TYPICAL
WINDOW NAILING FLANGE MUST
HAVE A CONTINUOUS LAP OF 1-1/8"
OVER THE SHEATHING
STEEL LINTEL, TYPICAL
- RE: GENERAL NOTES FOR SIZE &
BEARING REQUIREMENTS
WOOD HEADER
- PULL 1 4" FROM FACE OF VENEER
- REFER TO ELEVATION SHEET FOR
MATERIAL AND EXTENSION ON
EITHER SIDE OF WINDOW
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE.
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G.
3" = 1'-0"
18" MYLAR FLASHING
-EXTEND 8" BEYOND EA. SIDE OF
HEADER
-NAIL & CAULK T/ FLASH'G TO
SHEATHING, TYP.
BRICK WEEPHOLES, TYPICAL
-ANGLE UP FROM BTM OF SOLDIER
-2'-0" o.c. & AT EA. SIDE OF OPN'G
-KEEP WEEPS TO MINIMUM (3/16")
11 2" NAIL @ EVERY OTHER NAILING HOLE
IN WINDOW FLANGE.
- NAIL HEAD TO BE WIDER THAN HOLE IN
FLANGE
1 4" BEAD OF 'SONOLASTIC NP-1'
CAULK, CONT. BTWN FLANGE AND
SHEATHING
- TYPICAL, ALL (4) SIDES
WINDOW HEAD w/ 4x8 WD HEAD @ MASONRY VENEER
SCALE:07
7'-9"
FRAME TO EDGE
OF CONCRETE
AT DOOR
- w/ BARGE MOULD
1x6 FRIEZE BOARD
PRE-ENG. TRUSSES
@ 24" o.c.
3/8" HARDBOARD
NOTE:
1x8 TRIM 2x4 BLK'G.
@ COLUMNS
3/8" SHIMS
- MATCH TO 1x4
TRIM @ BRICK
7'-103 4"
AT DOOR
8"
OH
112"
7'-512"
PORCH DEPTH AT DOOR
5'-3"
WALL
BEYOND 112"
NOTE: ADJUST TO
GRADE FOR AESTHETIC
#4 RE-BAR @ 11" o.c.
- SIDE TO SIDE
#4 RE-BAR @ 18" o.c.
- FRONT TO BACK
PURPOSES ONLY
- FORM DOWN 12" MIN.
- PLACED BELOW FRONT
TO BACK BARS IN SLAB
- PLACED ABOVE SIDE
TO SIDE BARS IN SLAB
2x12 BEAM
FASTEN TRUSS TO 2x12
BEAM w/ (3) 16d NAILS
2x2 BLOCKING
618"
SECTION - FRONT PORCH
SCALE: 3/8" = 1'-0"
7'-27 8"
FRAME DIMENSION AT DOOR
VENTED SOFFIT
1x8 GUTTER BD
1x10 TRIM
4
12
- RIP TO 8 3/4"w.
ROUGH SAWN
CEDAR 1x8's
ROUGH SAWN
CEDAR 1x10's
1x4 & 1x6 TRIM
BLOCKING @
24"o.c.
ROUGH SAWN
CEDAR 1x10's
NOTE:
LAY BRICK THROUGH
TRUSSES
TRUSS HANGER
2x4 BLK'G. FOR
HANGERS
NAIL AND CAULK TOP
OF .40 MIL BUTYL TO
THERMOPLY SHT'G.
.40 MIL BUTYL FLSH'G
- ON TOP OF T-PLY SHT'G
& OVER FLASHING
BRICK VENEER
- WEEPHOLES @
24" O.C. OVER ROOF
METAL FLASHING
- SET INTO BRICK &
ONTO ROOF MATERIAL
08
3/4" = 1'-0"SCALE:
BRICK VENEER, TYP.
HARDBOARD FRIEZE
- REFER TO ELEVATIONS FOR
SIZES AND PROFILES
1x8 GUTTER BOARD, TYP.
ALUMINUM GUTTER
- REFER TO ELEVATIONS
FIBERGLASS ASPHALT
SHINGLES OVER 7/16" ROOF
SHEATHING
CULTURED STONE VENEER, TYP.
- HOLD OFF T/ SHINGLES 1"±
METAL FLASHING
- TURN OUT 3" ABOVE GUTTER
FLASHING @ STONE VENEER
DETAIL -
11
DETAIL - ROOF CRICKET
SCALE: 3/4" = 1'-0"09
1 1/2" = 1'-0"SCALE:
SUPPORTED BY ROOF TRUSS
DETAIL - BRICK VENEER
312" x 312" x 1 4"
STEEL LINTEL
METAL COUNTER FLASHING
- SET INTO BRICK &
ONTO STEP FLASHING
ROOF TRUSS
ICE & WATER SHIELD
- 36" WIDE, 12" UP WALL
& 24" ONTO ROOF
- INSTALLED BEHIND &
UNDER STEEL LINTEL
STEP FLASHING
NOTE:
TRUSS MANUFACTURER TO SIZE TRUSS
FOR ADDITIONAL BRICK LOADING
10
4'-03 4"
TO NOSING
6'-01 4"
TO NOSING
2'-6"
(3) TREADS @ 10"
4'-1114"
TO NOSING
11'-512"
TO NOSING
SECTION DETAIL - THRU STAIRS
SCALE: 3/8" = 1'-0"
4'-0"12"
01 REASON FOR PLOT: PLOT DATE: Job No.
Sheet No.INNEW RESIDENCE FOR: HOMESITE NO. MASTER BY: DATE: C DATE: FISCHER HOMES INDIANAPOLIS LP6602 E 75TH ST SUITE 400INDIANAPOLIS IN 46250317.348.2500FIELD SPEC HOTLINE: (859) 344-7100COPYRIGHT ALL RIGHTS RESERVED
FISCHER HOMES, Inc.JOB INFO: DATE: PHONE No: HOME TYPE: PLAN NO. EXTERIOR: 12/10/2018 3:18 PM OBF-071RAFAEL & ANNYMILIA BASSO14460 PEMBERTON LANEINGLENOOKG250AHOVERBROOK FARMS
CARMEL, IN 46074071 ---- ---- 2016 859.344.3115
11/30/18 CHRISTINA BISHOPGRAND ESTATE COLLECTION
fieldspecchange@fischerhomes.comREVISED BY: TEAM MANAGER:PHONE No:859.426.4223SHEZYRA SISKOWICA6.0
12/21/18
Mike Sheeks