HomeMy WebLinkAboutA01102 DOOR JAMB @ HORIZONTAL SIDING
SCALE:
PLAN DETAIL
HORIZONTAL SIDING, TYPICAL
J-CHANNEL TRIM, TYPICAL
1x TRIM SURROUND
- REFER TO ELEVATIONS
LINE OF THRESHOLD BELOW
ENTRY DOOR WITH FACTORY
APPLIED BRICK MOULD
CAULK CONTINUOUS OUTSIDE &
BEHIND BRICK MOULD:
- INSTALL IN SUCH A MANNER SO
AS TO PREVENT MOISTURE FROM
ENTERING THE TOP & SIDES OF
THE EXTERIOR DOOR OPN'G.
05 DOOR JAMB @ MASONRY VENEER
SCALE:
PLAN DETAIL
CAULK, CONTINUOUS
LINE OF THRESHOLD BELOW
LINE OF CONCRETE STEP
BELOW.
ENTRY DOOR WITH FACTORY
APPLIED BRICK MOULD
CAULK CONTINUOUS OUTSIDE &
BEHIND BRICK MOULD:
- INSTALL IN SUCH A MANNER SO
AS TO PREVENT MOISTURE FROM
ENTERING THE TOP & SIDES OF
THE EXTERIOR DOOR OPN'G.
REFER TO TYPICAL WALL SECTIONS AND
GENERAL NOTES FOR BRICK TIE
REQUIREMENTS.
MASONRY VENEER, TYP.
- BRICK SHOWN, STONE SIM.
10DOOR HEAD WITH WOOD TRIM PANEL ABOVE
SCALE: 3" = 1'-0"
08 SCALE:
DOOR JAMB WITH WOOD TRIM
PLAN DETAIL
CAULK, CONTINUOUS
MASONRY VENEER, TYPICAL
LINE OF THRESHOLD BELOW
LINE OF CONCRETE STOOP
BELOW.
1x TRIM OVER P.T. 5/4 BACK-UP
- REFER TO ELEVATIONS
ENTRY DOOR WITH FACTORY
APPLIED BRICK MOULD
CAULK CONTINUOUS OUTSIDE &
BEHIND BRICK MOULD:
- INSTALL IN SUCH A MANNER SO
AS TO PREVENT MOISTURE FROM
ENTERING THE TOP & SIDES OF
THE EXTERIOR DOOR OPN'G.
11 DOOR HEAD @ COVERED PORCH
SCALE:
ENTRY DOOR WITH FACTORY
APPLIED BRICK MOULD
CAULK CONTINUOUS OUTSIDE &
BEHIND BRICK MOULD:
- INSTALL IN SUCH A MANNER SO
AS TO PREVENT MOISTURE FROM
ENTERING THE TOP & SIDES OF
THE EXTERIOR DOOR OPN'G.
BRICK BEYOND
2x CEILING RAFTER
- REFER TO PLANS & SECTIONS
06 DOOR THRESHOLD @ BRICK VENEER
SCALE:
8"
8" THICK CAST-IN-PLACE
CONCRETE FOUNDATION WALL:
- UNLESS NOTED OTHERWISE
ON FOUNDATION PLAN
CAULK, CONTINUOUS
DOOR JAMB BEYOND
5/8x4 BLOCKING, TYPICAL
BRICK ROWLOCK SILL
- SLOPE 1/4"
- HOLD 1/4" BELOW
THRESHOLD, TYP.
FINISH FLOORING SHOWN DASHED
- REFER TO PLANS
BRICK VENEER BEYOND
'FLASH & SEAL' FLASHING
6"1/2" FIBER EXPANSION BOARD,
TYPICAL
CONC. HAUNCH BEYOND REFER
TO FOUNDATION PLANS
ALUMINUM PAN
- SET IN 3 BEADS OF CAULK
12MASONRY VENEER w/ DECORATIVE SURROUND
SCALE:
8"
8" THICK CAST-IN-PLACE
CONCRETE FOUNDATION WALL:
- UNLESS NOTED OTHERWISE
ON FOUNDATION PLAN
1x6 TRIM OVER P.T. 1x BLOCKING
- HOLD 1/4" BELOW THRESHOLD
- HOLD 1/4" OFF T/ PORCH SLAB
- w/ 45° BEVEL @ TOP
FLASH & SEAL' FLASHING
6"CAULK, CONTINUOUS
SYNTHETIC DECORATIVE DOOR
SURROUND BEYOND
-REFER TO ELEV'S
DOOR THRESHOLD
CONC. HAUNCH BEYOND REFER
TO FOUNDATION PLANS
CAULK, CONTINUOUS
DOOR JAMB BEYOND
FINISH FLOORING SHOWN DASHED
- REFER TO PLANS
BRICK VENEER BEYOND
5/8x4 BLOCKING, TYPICAL
ALUMINUM PAN
- SET IN 3 BEADS OF CAULK
DOOR HEAD @ HORIZONTAL SIDING01 SCALE:
HORIZONTAL SIDING, TYPICAL
STRUCTURAL SHEATHING, TYPICAL
ENTRY DOOR WITH FACTORY
APPLIED BRICK MOULD
OVERLAP STRUCTURAL SHEATHING 2"
@ TOP PLATE TYPICAL.
1x TRIM, TYPICAL
- REFER TO ELEVATIONS
J-CHANNEL TRIM, TYPICAL
CAULK CONTINUOUS OUTSIDE &
BEHIND BRICK MOULD:
- INSTALL IN SUCH A MANNER SO
AS TO PREVENT MOISTURE FROM
ENTERING THE TOP & SIDES OF
THE EXTERIOR DOOR OPN'G.
24" POLY FLASHING @ BAND
BOARD, TYPICAL
BREAK MTL DRIP EDGE FLASH'G:
- NAIL & CAULK T/ FLASHING TO WALL
SHEATHING, TYPICAL
- EXTEND FLASH'G 1/2"± BEYOND
OUTSIDE EDGE OF BRICK MOULD
- SUPPLIED & INSTALLED BY DOOR
INSTALLER.
5/16" HARDIPANEL - SMOOTH FINISH,
TYPICAL
- HOLD 1/4" OFF BRICK MOULD
1x TRIM, TYPICAL
- HOLD TRIM 1/16" OFF BRICK MOULD
- REFER TO ELEVATIONS FOR SIZES AND
PROFILES
VENEER BEYOND
- REFER TO ELEVATIONS, (BRICK
SHOWN)
BREAK MTL DRIP EDGE FLASH'G:
- NAIL & CAULK T/ FLASHING TO WALL
SHEATHING, TYPICAL
- EXTEND FLASH'G 1/2"± BEYOND
OUTSIDE EDGE OF BRICK MOULD
- SUPPLIED & INSTALLED BY DOOR
INSTALLER
ENTRY DOOR WITH FACTORY
APPLIED BRICK MOULD
CAULK CONTINUOUS OUTSIDE &
BEHIND BRICK MOULD:
- INSTALL IN SUCH A MANNER SO
AS TO PREVENT MOISTURE FROM
ENTERING THE TOP & SIDES OF
THE EXTERIOR DOOR OPN'G.
1x TRIM, TYPICAL
- w/ 30° BEVEL @ TOP EDGE
- HOLD TRIM 1/16" OFF BRICK MOULD
- REFER TO ELEVATIONS FOR SIZES AND
PROFILES
PVC MOULDING, TYPICAL
- REFER TO ELEVATIONS FOR SIZE AND
LOCATION
3" = 1'-0"
3" = 1'-0"
3" = 1'-0"3" = 1'-0"
3" = 1'-0"
3" = 1'-0"
3" = 1'-0"
03 DOOR THRESHOLD @ SIDING / CULTURED STONE
SCALE: 3" = 1'-0"
8"
8" THICK CAST-IN-PLACE
CONCRETE FOUNDATION WALL
- UNLESS NOTED OTHERWISE
ON FOUNDATION PLAN
CAULK, CONTINUOUS
DOOR JAMB BEYOND
1x6 TRIM, TYPICAL
- HOLD 1 4" BELOW THRESHOLD
- HOLD 1 4" OFF T/ PORCH SLAB
FINISH FLOORING SHOWN DASHED
- REFER TO PLANS
6"CAULK, CONTINUOUS
CONC. HAUNCH BEYOND REFER
TO FOUNDATION PLANS
STRUCTURAL SHEATHING
- EXTEND SHEATHING TO
12" BELOW T/ FDN WALL
- w/ POLY EXTENDED 1"
BELOW T/ FOUNDATION
5/8 x 4 BLOCKING, TYPICAL
ALUMINUM PAN
- SET IN 3 BEADS OF CAULK
'FLASH & SEAL' FLASHING
METAL DRIP
- NAIL & TAPE TO SHEATHING
- USE 1" ROOFING NAILS @ EA. STUD
07 SCALE: 3" = 1'-0"
DOOR HEAD WITH WOOD TRIM
STEEL LINTEL, TYPICAL
- RE: GENERAL NOTES FOR SIZE &
BEARING REQUIREMENTS
CAULK, CONTINUOUS
1x TRIM OVER P.T. 5/4 BACK-UP
- REFER TO ELEVATIONS
BREAK MTL DRIP EDGE FLASH'G:
- NAIL & CAULK T/ FLASHING TO WALL
SHEATHING, TYPICAL
- EXTEND FLASH'G 1/2"± BEYOND
OUTSIDE EDGE OF BRICK MOULD
- SUPPLIED & INSTALLED BY DOOR
INSTALLER
ENTRY DOOR WITH FACTORY
APPLIED BRICK MOULD
CAULK CONTINUOUS OUTSIDE &
BEHIND BRICK MOULD:
- INSTALL IN SUCH A MANNER SO
AS TO PREVENT MOISTURE FROM
ENTERING THE TOP & SIDES OF
THE EXTERIOR DOOR OPN'G.
MASONRY VENEER
MASONRY VENEER, TYP.
- BRICK SHOWN, STONE SIM.
18" MYLAR FLASHING
-EXTEND 8" BEYOND EA. SIDE OF
DOOR
-NAIL & CAULK T/ FLASH'G TO
SHEATHING, TYP.
BRICK WEEPHOLES, TYPICAL
-ANGLE UP FROM BTM OF SOLDIER
-2'-0" o.c. & AT EA. SIDE OF OPN'G
-KEEP WEEPS TO MINIMUM (3/16")
04 SCALE: 3" = 1'-0"
DOOR HEAD @ MASONRY VENEER
STEEL LINTEL, TYPICAL
- RE: GENERAL NOTES FOR SIZE &
BEARING REQUIREMENTS
ENTRY DOOR WITH FACTORY
APPLIED BRICK MOULD
CAULK CONTINUOUS OUTSIDE &
BEHIND BRICK MOULD:
- INSTALL IN SUCH A MANNER SO
AS TO PREVENT MOISTURE FROM
ENTERING THE TOP & SIDES OF
THE EXTERIOR DOOR OPN'G.
MASONRY VENEER, TYP.
- BRICK SHOWN, STONE SIM.
NOTE:
1"± AIR SPACE @ BRICK VENEER,
TYPICAL
GROUT SOLID W/ 15# FELT OR
OTHER APPROVED
WEATHER-RESISTANT MATERIAL
@ STONE VENEER ONLY, TYPICAL
09 ARCHED DOOR HEAD @ BRICK VENEER
SCALE: 3" = 1'-0"
MASONRY VENEER, TYPICAL
CAULK, CONTINUOUS
1x TRIM OVER P.T. 5/4 BACK-UP
- REFER TO ELEVATIONS
ARCHED BRICK HEADER
- BRICK SHOWN, STONE SIM.
BREAK MTL DRIP EDGE FLASH'G:
- NAIL & CAULK T/ FLASHING TO WALL
SHEATHING, TYPICAL
- EXTEND FLASH'G 1/2"± BEYOND
OUTSIDE EDGE OF BRICK MOULD
- SUPPLIED & INSTALLED BY DOOR
INSTALLER
ENTRY DOOR WITH FACTORY
APPLIED BRICK MOULD
CAULK CONTINUOUS OUTSIDE &
BEHIND BRICK MOULD:
- INSTALL IN SUCH A MANNER SO
AS TO PREVENT MOISTURE FROM
ENTERING THE TOP & SIDES OF
THE EXTERIOR DOOR OPN'G.
18" MYLAR FLASHING
-EXTEND 8" BEYOND EA. SIDE OF
DOOR
-NAIL & CAULK T/ FLASH'G TO
SHEATHING, TYP.
BRICK WEEPHOLES, TYPICAL
-ANGLE UP FROM BTM OF SOLDIER
-2'-0" o.c. & AT EA. SIDE OF OPN'G
-KEEP WEEPS TO MINIMUM (3/16")
BREAK MTL DRIP EDGE FLASH'G:
- NAIL & CAULK T/ FLASHING TO WALL
SHEATHING, TYPICAL
- EXTEND FLASH'G 1/2"± BEYOND
OUTSIDE EDGE OF BRICK MOULD
- SUPPLIED & INSTALLED BY DOOR
INSTALLER
18" MYLAR FLASHING
-EXTEND 8" BEYOND EA. SIDE OF
DOOR
-NAIL & CAULK T/ FLASH'G TO
SHEATHING, TYP.
BRICK WEEPHOLES, TYPICAL
-ANGLE UP FROM BTM OF SOLDIER
-2'-0" o.c. & AT EA. SIDE OF OPN'G
-KEEP WEEPS TO MINIMUM (3/16")REASON FOR PLOT: PLOT DATE: Job No.
Sheet No.INNEW RESIDENCE FOR: HOMESITE NO. MASTER BY: DATE: C DATE: FISCHER HOMES INDIANAPOLIS LP6602 E 75TH ST SUITE 400INDIANAPOLIS IN 46250317.348.2500FIELD SPEC HOTLINE: (859) 344-7100COPYRIGHT ALL RIGHTS RESERVED
FISCHER HOMES, Inc.JOB INFO: DATE: PHONE No: HOME TYPE: PLAN NO. EXTERIOR: 12/10/2018 3:19 PM OBF-071RAFAEL & ANNYMILIA BASSO14460 PEMBERTON LANEINGLENOOKG250AHOVERBROOK FARMS
CARMEL, IN 46074071 ---- ---- 2016 859.344.3115
11/30/18 CHRISTINA BISHOPGRAND ESTATE COLLECTION
fieldspecchange@fischerhomes.com
REVISED BY: TEAM MANAGER:PHONE No:859.426.4223SHEZYRA SISKOWICD1.0
12/21/18
Mike Sheeks