HomeMy WebLinkAboutS001HB TION OF THE RADON EXHAUST PIPE IN THE HVAC CHASE AREA. 5. PLUMBER AND HVAC SUBCONTRACTOR TO COORDINATE THE INSTALLA- ABOVE THE SURFACE OF THE ROOF IN A LOCATION 10 FEET AWAY FROM VERTICALLY INTO THE SUB SLAB AGGREGATE AND THROUGH THE UP THROUGH THE BUILDING FLOORS & TERMINATE AT LEAST 12 INCHES ANY WINDOW OR OTHER OPENINGS INTO THE CONDITIONED SPACES OF OF VERTICAL DISTANCE WHERE THE VENT PASSES THROUGH THE ATTIC IN ADDITION, FISCHER HOMES WILL PROVIDE APPROXIMATELY 6 FEET SHEETING BEFORE THE SLAB IS POURED. THE PIPE SHALL BE EXTENDED THE BUILDING THAT IS LESS THAN 2 FEET BELOW THE EXHAUST POINT. 3. A 3 INCH DIAMETER SCH 40 PVC PLUMBING TEE SHALL BE EMBEDDED FOR THE POSSIBLE INSTALLATION OF A FUTURE EXHAUST FAN. NOTE: ALL FITTINGS ARE TO GLUED AND SECURED AS NEEDED. FISCHER HOMES RADON REDUCTION SYSTEM NOTES: THE FOLLOWING ITEMS ARE TO BE INSTALLED AS PART OF FISCHER HOMES RADON REDUCTION SYSTEM: 1. A UNIFORM LAYER OF CLEAN AGGREGATE AT A MINIMUM OF 4 INCHES UNDER THE CONCRETE SLAB. 2. A 6 MIL POLYETHYLENE OR EQUIVALENT FLEXIBLE SHEETING MATERIAL SHALL BE PLACED ON TOP OF THE GRAVEL. THE SHEETING SHALL FIT CLOSELY AROUND ANY PIPE, WIRE, OR OTHER PENETRATIONS OF THE MATERIAL. ALL PUNCTURES OR TEARS IN MATERIALS SHALL BE SEALED OR COVERED WITH ADDITIONAL SHEETING. 4. TO PROVIDE FOR FUTURE INSTALLATION OF AN ACTIVE SYSTEM, AN ELECTRICAL CIRCUIT TERMINATED IN AN APPROVED BOX SHALL BE INSTALLED DURING CONSTRUCTION IN THE ATTIC WITHIN 4'-0" OF THE RADON PIPE FOR THE POSSIBLE INSTALLATION OF A FUTURE EXHAUST FAN. FOUNDATION WATER-PROOFING NOTES: 1. AN APPROVED WATERPROOFING MEMBRANE IS REQUIRED FOR EXTERIOR FOUNDATION WALLS THAT ENCLOSE THE BASEMENT AREA & SHALL EXTEND FROM TOP OF THE FOOTING TO THE FINISHED GRADE. 2. JOINTS IN THE MEMBRANE SHALL BE LAPPED & SEALED WITH AN ADHESIVE COMPATIBLE WITH THE WATERPROOFING MEMBRANE. HIGHEFFICIENCYGAS FURNACEBASEMENT and LOWER LEVEL FOUNDATION / FOOTING PLAN01 NOTE: REFER TO BOXED NOTE FOR DAMP OR WATER PROOFING. ALSO APPLIES TO THIS WALL. 6" SLEEVE THRU BASEMENT FOOTING FOR CONTINUOUS DRAIN TILE 17'-73 4" TO ℄ STEEL BEAM / COLUMN 17'-23 4" TO ℄ STEEL BEAM / COLUMN 12'-112" TO ℄ FLOOR DRAIN 13'-1"TO ℄ STEEL COLUMN6'-214" TO ℄ RADON PIPE 6" SLEEVE THRU BASEMENT FOOTING FOR CONTINUOUS DRAIN TILE CONTROL JOINT 4" x 8" x 8"d. BEAM POCKET 3'-11" TO NOSING8'-412"4'-0" 4" x 4" LEDGE @ TOP OF WALL FOR SLAB SUPPORT FURNACE INTAKE & EXHAUST 10" C.I.P. CONCRETE FOUNDATION WALLS CONCRETE FOOTINGS 8" x 20" C.I.P. WH P.V. GAS FD BASEMENT W8 x 24 STEEL BEAMREDUCTION PIPE - SEE DTL. 02/A2.1 3" Ø PVC RADON UNEXCAVATED 24" x 24" PIER - DEPTH TO BEARING SOIL - SEE DTL. 09/A2.1 36" x 36" x 8"d. C.I.P. CONCRETE FOOTING - SHOWN BELOW PIER - SEE DTL. 09/A2.1 6"thk. CONC. GARAGE SLAB - PROVIDE #4 RE-BARS @ 12"o.c. EA. WAY w/ MIN. 3" COVERAGE - SEE DTL's. 09-10/A2.1 3" LEDGE FOR GRADE BEAM SUPPORT - SEE DTL. 06/A2.1 8" 19'-3"6'-5"h. FOUNDATION WALL3" 10"10" 4'-2"17'-11" CONTROL JOINT 42" x 42" x 18" THICK C.I.P. CONCRETE COLUMN FOOTING - HOLD T/ FT'G. DOWN 3 12" FROM T/ SLAB 4" Ø 11ga STEEL COLUMN 48" x 48" x 18" THICK C.I.P. CONCRETE COLUMN FOOTING - HOLD T/ FT'G. DOWN 3 12" FROM T/ SLAB 3" Ø SCH40 STEEL COLUMN INSULATE FLAT FRAMED WALL w/ 2" THERMAX 9'-51 4" TO ℄ PIER / FT'G. (2) 2x4 JACK STUDS 55'-1112"OVERALL NOTE: FLOOR SLAB STEPS UP 6'-112" @ 7'-9 5/8"h. FOUNDATION WALL 23'-212" TO NOSING UP CARPET HOLD T/ WALL DOWN 4" FOR SLAB POUR-THRU @ STAIR LANDING 6'-3"FOUNDATION GENERAL NOTES: 1. PROVIDE CONTROL JOINTS IN SLAB @ ALL BEAM AND COLUMN ℄'s - AND AS NOTED 2. USE 6 MIL POLY VAPOR BARRIER UNDER BASEMENT SLAB 3. USE PRESSURE-TREATED LUMBER @ ALL PLACES OF CONTACT w/ CONCRETE 2'-4"5'-0" 312"8'-8"512"36" VANITY312" 312"10'-9" TO ℄ SHOWER DRAIN 17'-338"TO ℄ SHOWER DRAIN12'-9" 7'-912"20'-278"TO ℄ TOILET DRAIN9'-3" TO ℄ TOILET DRAIN 9'-9"TO ℄ FLOOR DRAIN14'-8"TO ℄ STEEL COLUMN14'-634"TO ℄ RADON PIPE35'-5" 9'-0"h. FOUNDATION WALL 12'-012" 8'-8" INC22'-512"9'-0"h. FOUNDATION WALL10"20'-4"4'-8" - STUBBED OUT & LOOPED #4 RE-BAR HOLD T/ WALL DOWN 31 2" FROM T/ FDN. WALL 2x4 LET-IN FOR SLAB SUPPORT LINE OF PORCH ABOVE #4 RE-BAR @ 11" o.c. - SIDE TO SIDE - PLACED ABOVE SIDE #4 RE-BAR @ 18" o.c. - FRONT TO BACK TO SIDE BARS IN SLAB - PLACED BELOW FRONT TO BACK BARS IN SLAB 19'-912" 4'-0"h. FOUNDATION WALL 2'-712"68'-0" OVERALL 20'-7" 6'-0"h. FOUNDATION WALL 12'-7" 12"w. x 20"d. C.I.P. CONC. GRADE BEAM - SEE DTL. 06/A2.1 7'-11"TO ℄ PIER / FT'G.7" 8" 16'-0" 22'-312"4'-0"h. FDN WALL8'-0" 2'-0"7'-11"TO ℄ PIER / FT'G.9'-51 4" TO ℄ PIER / FT'G. 11'-11" 4'-0"h. FOUNDATION WALL 24'-7"4'-0"h. FDN WALL12'-0" 6'-0"h. FOUNDATION WALL 1'-7"9'-0" 1'-5" UNEXCAVATED 2x4 NOTCH SLOPED 3" FROM REAR TO FRONT FOR SLAB SUPPORT - SEE DTL. 10/A2.1 12"w. x 20"d. C.I.P. CONC. GRADE BEAM - SEE DTL. 06/A2.1 HOLD T/ GARAGE SLAB DOWN 6" FROM T/ FDN. & SLOPE TO O.H. DOOR 3" LEDGE FOR GRADE BEAM SUPPORT - SEE DTL. 06/A2.1 10" REC ROOM FOR SLAB SUPPORT FROM REAR TO FRONT 2x4 NOTCH SLOPED 3" - SEE DTL. 10/A2.1 HOLD T/ GARAGE SLAB DOWN 6" FROM T/ FDN. & SLOPE TO O.H. DOOR 21'-1112"TO ℄ STEEL COLUMN68'-0" OVERALL 16" BRICK CURB 36'-312"55'-1112"OVERALL 51'-412"9'-0"h. FOUNDATION WALL10"16'-312"20'-0" 14'-812" 11" 1'-4"2'-212" 2'-1012" HOLD T/WALL DOWN 12" FROM GRADE w/ HUMIDIFIER2"4" Ø 11ga STEEL COLUMN 42" x 42" x 18" THICK C.I.P. CONCRETE COLUMN FOOTING - HOLD T/ FT'G. DOWN 3 12" FROM T/ SLAB FULL BATH ROUGH-IN 8"10" 11'-1" 24'-012"6'-8"2'-0"2'-11"FOUNDATION WALL NOTES: BASEMENT FOUNDATION WALLS BASEMENT FOUNDATION WALLS ARE TO BE 10"thk., 9'-0"h. OFF T/ FOOTING. FOOTINGS TO BE 20"w. GARAGE FOUNDATION WALLS GARAGE FOUNDATION WALLS VARY, 6'-0"h. OFF T/ FOOTING. FOOTINGS VARY 8" 10"10"1'-8" 8" 19'-012"4'-11"3'-8" PUMP SUMP ELECTRICAL PANEL HOLD T/FDN. WALL DOWN 18" FOR SLAB POUR-THRU 8"2'-0" CARPET HANDRAIL - ONE SIDE 9'-514" WET BAR ROUGH-IN 31'-812" 7'-912"TO ℄ PIER / FT'G.512"18'-1012" 3'-6"4'-212" TO NOSING UP CARPET 7'-6"3'-8"SECTION DETAIL - LOWER LEVEL SCALE: 3/4" = 1'-0" FINISH GRADE - VARIES - SEE EXTERIORS, SHEET # A1.0 - HOLD DOWN MIN. 8 1/2" FROM TOP OF WALL 8" THICK CAST-IN-PLACE CONCRETE FDN WALL: ON FOUNDATION PLAN - UNLESS NOTED OTHERWISE BITUMINOUS ASPHALT ALL WALL TIES, CONTROL JOINTS, & COLD JOINTS. - SPRAY APPLY (2) COATS BITUMINOUS DAMPROOFING BELOW GRADE,TYPICAL. - REFER TO FOUND. PLAN FOR WATERPROOFING INFO. IF REQUIRED. GRAVEL FILL 2x4 PRESSURE-TREATED SILL PLATE: - STRAPPED TO FOUNDATION PER MANUFACTURER'S RECOMMENDATION - APPLY CONTINUOUS POLY SILL SEALER TO SILL , TYP. 6 MIL POLY VAPOR BARRIER 3 12" THICK CONCRETE SLAB - ON MIN. 4" GRAVEL BASE 2x10 No. 1 KD SOUTHERN PINE FLOOR JOISTS @ 19.2" o.c. T&G O.S.B. SUBFLOOR - GLUED, NAILED AND SCREWED BRICK VENEER (STRUCTURAL & STRUCTURAL SHEATHING - UNLESS NOTED OTHERWISE ON PLAN T/ FOOTING T/ LOWER LEVEL DBL. TOP  T/ SLAB & FND. WALL T/ MASTER BEDRM. SUBFLOOR NOTE: SEE WALL SECTION SHEETS "WS" FOR STEEL REINFORCEMENT EXPANSION JOINT WATER REPELLENT) 1'-0" 1'-10" 8" THICK CAST-IN-PLACE CONCRETE FDN WALL ON FOUNDATION PLAN - UNLESS NOTED OTHERWISE 1x10 MDF CAP - w/ COVE MOULD WHERE TRIM MEETS DRYWALL DBL 2x4 FRAME WALL - w/ PT 2x10 TOP PLATE - RIP TO 8 1 2"w. - w/ BATT INSUL. - w/ 12" DRYWALL T/ FRAME WALL 02 8"8"19'-3" 5'-4"HANDRAIL5'-1"9'-0"h. FDN WALL4'-0"9'-0"h. FDN WALLSOFT R/I WATER 5'-8" 5'-8"11'-7"11'-8" 24" x 24" PIER - DEPTH TO BEARING SOIL - SEE DTL. 09/A2.1 36" x 36" x 8"d. C.I.P. CONCRETE FOOTING - SHOWN BELOW PIER - SEE DTL. 09/A2.1 HOLD T/ WDW TO T/ FDN. WALL HOPPER WINDOW 32"w. x 23"h. PUMP EJECTOR16" B.C.16" B.C.8" B.C.16" B.C.HOLD T/ WDW TO T/ FDN. WALL HOPPER WINDOW 32"w. x 23"h. 4'-2"11'-8" 4'-2" 7'-83 8" 7'-838" 8'-0"18" DIA. CONC. PIER MIN. 32" DEEP LINE OF PATIO ABOVE 7'-83 8"8'-0"LINE OF PATIO ABOVE 8" B.C. 8" B.C. REASON FOR PLOT: PLOT DATE: Job No. Sheet No.INNEW RESIDENCE FOR: HOMESITE NO. MASTER BY: DATE: C DATE: FISCHER HOMES INDIANAPOLIS LP6602 E 75TH ST SUITE 400INDIANAPOLIS IN 46250317.348.2500FIELD SPEC HOTLINE: (859) 344-7100COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc.JOB INFO: DATE: PHONE No: HOME TYPE: PLAN NO. EXTERIOR: 12/10/2018 3:18 PM OBF-071RAFAEL & ANNYMILIA BASSO14460 PEMBERTON LANEINGLENOOKG250AHOVERBROOK FARMS CARMEL, IN 46074071 ---- ---- 2016 859.344.3115 11/30/18 CHRISTINA BISHOPGRAND ESTATE COLLECTION fieldspecchange@fischerhomes.comREVISED BY: TEAM MANAGER:PHONE No:859.426.4223SHEZYRA SISKOWICA2.0 12/21/18 Mike Sheeks