Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
S100
GARAGE DRYWALL NOTE: ALL GARAGE WALLS, CEILING, BEAMS, COLUMNS AND WALLS THAT SUPPORT FLOOR-CEILING ASSEMBLY ABOVE TO HAVE 12"DRYWALL (FINISHED). CEILING TO BE 5 8" TYPE "X" FIRECODE DRYWALL BELOW HABITABLE SPACES. 5 1 UP HARDWD. DN HARDWD. HEADER & BEAM NOTE: NOTES SHEET FOR ALL MULTIPLE 2x HEADERS & MULTIPLE LVL BEAMS. & NAILING DIAGRAM ON GENERAL REFER TO STRUCTURAL NOTE # 6 J.S. (1) 412" 412" ON INSIDE OF SGL. HDR. SGL. 2x12 HEADER J.S. (1) 2x4 WALL FRAMING @ 16" o.c. - TYPICAL REFER TO SHEET A3 FOR WINDOW OPN'G SIZES J.S. (1) J.S. (1) J.S. (1) J.S. (1) BOTTOM and MIDPOINT 2x4 BLOCKING @ TOP & SCALE: 3/8" = 1'-0"03 HBFLOOR PLAN NOTE: 1. EXTERIOR WALLS SHALL BE FRAMED @ 16" o.c. 2. INTERIOR WALLS SHADED AS INDICATES INTERIOR LOAD BEARING WALL TO BE FRAMED @ 19.2" o.c. - ALIGN JOISTS w/ STUDS. 3. INTERIOR WALLS SHADED AS INDICATES INTERIOR LOAD BEARING and/or NON LOAD BEARING WALLS TO BE FRAMED @ 24" o.c. - EXCEPT AREAS THAT ARE TO BE FRAMED @ 16" o.c. PER FISCHER HOMES SCOPES & STANDARDS. 1 1 4'-412" 4'-412" 5060P MAIN LEVEL and LOWER LEVEL FLOOR PLAN01 REF. SPACE MORNING ROOM FOYER HARDWOOD POWDER TWO-CAR GARAGE KITCHEN STUDY FAMILY ROOM 10'-5 5/8"h. CEILING 9'-1"h. CEILING 9'-1"h. CEILING 9'-1"h. CEILING TWO-STORY HARDWOOD 9'-1"h. CEILING DINING 9'-1"h. CEILING DOUBLE FRENCH DOOR HARDWOOD HARDWOOD HARDWOOD HARDWOOD TWO-STORY @ 7'-10 5/8" OFF T/ FDN. WALL SET GARAGE WALL HEIGHT NOTE: 34 1/2"h. HALF WALL - w/ 1x10 MDF CAP & COVE MOULD - HOLD 1/2" FROM FACE OF FOUNDATION WALL HANDRAIL RADON PIPE NOTE: SET T/ WINDOWS @ 6'-67 8" OFF T/ FDN. WALL PAD OUT WALL FOR PLUMBING WOOD RAILING 20-MIN.2'-6"2'-4"x8'2'-4"x8'2'-6"x8'-0"2'-4"x8'2860 5060P 2860 19'-8 1 2" 7'-105 8"h. FRAME WALL 19'-10" 2x6 BALLOON FRAME WALL 4'-7" 5'-214" 4'-7" 5'-53 4" 5'-4" 5'-71 2" 15'-1 12" 5 1 2" 19'-61 2" 3'-1" OPENING 2'-8 12"9 1 2 " 8'-61 2 " 51 2 " 11'-5 1 2" TO NOSING 4'-2" 3'-9" TO NOSING 6'-0 1 4" TO NOSING 9'-3 3 4" 3'-1" OPENING 2'-8 12"9'-4" 5 1 2" 15'-1 12"7'-2 1 2" 5 1 2" 12'-012" 19'-5" 8'-81 2 " 6'-31 2"6'-234"512" 512"1'-7" ℄1'-7" ℄4'-3" 1'-3" 4'-2"℄4'-214"7'-912" 18'-0"512"1'-8" ℄ 512"1'-6"11'-11"3'-4"734"5'-0" 5'-7 1 2" 512"2'-334"4'-0"9'-212" 5 1 2" 1'-7"℄ 2'-0" 9'-1"h. CEILING HARDWOOD 3'-7" (3) 2x4 JACK STUDS CEILING RAISED TO 7'-2 7/8" FROM T/ MAIN LEVEL SUBFLR. 2'-2" 6'-112" 'NOVUS' # NDV4236I GAS DIRECT VENT FIREPLACE - RO: 42"w. x 35"h. - SEE DETAILS ON SHEET FP1 FLAT FRAME WALL BELOW T/ FOUNDATION - INSULATE w/ R-10 RIGID INSULATION (2) 2x4 JACK STUDS1'-1012" SPANDREL BEAM NOTE: USE (2) 2x10's w/ 12" PLYWOOD FLITCH AS SPANDREL BEAM - SET FLUSH w/ 2nd FLR. JOISTS DOUBLE WINDOW HEADER NOTE: USE SINGLE 2x12 AS HEADER w/ (1) JACK STUD @ EACH SIDE OF EACH WINDOW TRIPLE WINDOW HEADER NOTE: - SEE DTL. FOR BLOCKING INFO. USE SINGLE 2x12 AS HEADER w/ (1) JACK STUD @ EACH SIDE OF EACH WINDOW 03/A3.0 BLS-30802264/1P 20563056 2056 30603060 12'-4" 9'-1"h. FRAME WALL 14'-012" 9'-1"h. FRAME WALL 4'-4" 3'-412" 4'-712" 4'-13 4" 4'-5" 2'-10 12" 4'-13 4"2'-10 12" 1'-212" 14'-612" 11'-4" 24'-1" 3'-0"x8'-0"3'-118"834" 24'-5"w. x 5'-4 1/2"d. PORCH 30563056 4'-53 4" 3'-012" 4'-53 4" 12'-0" 10'-2 12"h. FRAME WALL 8'-0" 7'-1058"h. FRAME WALL 2456 3'-1014" 4'-13 4" @ 8'-10 3/4" OFF T/ FDN. WALL SET GARAGE WINDOWS NOTE: @ 10'-2 1/2" OFF T/ FDN. WALL SET BUMP-OUT GARAGE WALLS NOTE: 67'-5" DIMENSIONS ARE FRAME TO FRAME 12'-0" 9'-1"h. FRAME WALL22'-312"7'-1058"h. FRAME WALL1'-112" 9'-0" 1'-10 12"19'-2"REC ROOM 3060 3060 4'-6" TO NOSING FOYER FAMILY 16'-0" 2'-11" 16FT OH GARAGE DOOR HEADER NOTE: 24'-0"9'-1"h. FRAME WALL12'-0" 9'-1"h. FRAME WALL THIRD-CAR GARAGE NOTE: @ 9'-1" ABV. T/ FDN. WALL GARAGE DRYWALL NOTE: ALL GARAGE WALLS & CEILING AND ANY WALLS, CEILINGS, BEAMS, COLUMNS AND WALLS THAT SUPPORT FLOOR-CEILING ASSEMBLY ABOVE TO HAVE 12" DRYWALL (FINISHED). SET GARAGE WALL HEIGHT 512"4'-71 2"9'-1"h. FRAME WALLAP 2 2 DW24NOTE: 3412"h. WALLS BUILT BY TRIM CARPENTER WHILE INSTALLING CABINETS - SEE DTL. 04/A4.0 SINK 6'-612" 5'-0"8'-3"6'-534" 6'-3"2'-03 4" 8'-6 12"7'-512"7'-758"TO ℄ RANGE HOOD/OPT. MICROWAVEPLUMBER'S NOTE! PROVIDE ROUGH-IN FOR ICE MAKER 22'-8"OPENINGFLUSH BEAM NOTE: USE (2) 1 3 4" x 20"LVL's - SET T/ BEAM FLUSH WITH T/ 2x10 FLOOR JOISTS ABOVE - w/ (2) 2x6 JACK STUDS @ EACH END - BEAM TO BE 25'-412" LONG 1'-7"℄ JACKSTUDS2020P2020P 2020P 50'-912"9'-1"h. FRAME WALL2'-9" 2'-9" 15'-8 12" 9'-1"h. FRAME WALL 28'-614" 55'-412"DIMENSIONS ARE FRAME TO FRAME67'-5" DIMENSIONS ARE FRAME TO FRAME 35'-8 12"55'-412"DIMENSIONS ARE FRAME TO FRAME2" 4'-0"2'-112"FLUSH BEAM NOTE: USE (2) 13 4" x 16" LVL's - SET BTM/ BEAM FLUSH w/ BTM/2x10 FLOOR JOISTS ABOVE - w/ (2) 2x6 JACK STUDS @ CORNER - w/ (4) 2x4 JACK STUDS @ WALL 39'-8" 5'-712"9'-012" 9'-1"h. FRAME WALL 4'-712" 1 1 8 3 2 1 3 2 4 3 5 1 6 1 7 2 8 3 9 1 10 1 11 2 123 13 1 14 1 15 2 16 3 17 1 18 1192 203 211 221 232 243 PLAN NOTES: DOOR and WINDOW ROUGH OPENING NOTES: * 9'-1" 1st FLOOR and 2nd FLOOR PLATE HEIGHT. * ASSUME THE FOLLOWING FOR ALL FRAME OPENINGS, UNLESS ON THE PLANS: - FRAME ALL 1st & 2nd FLOOR WINDOW HEADERS AT 93 1 4" OFF SUBFLOOR - FRAME ALL 8'-0"h. EXTERIOR BEARING DOOR HEADERS AT 99 1 4" OFF SUBFLOOR FOR FLOOR MATERIALS. - FRAME ALL 8'-0"h. INTERIOR BEARING DOOR HEADERS AT 98 3 4" OFF SUBFLOOR FOR FLOOR MATERIALS. - FRAME ALL 8'-0"h. INTERIOR NON-LOAD BEARING DOOR and BI-PASS DOOR HEADERS AT 98 3 4" OFF SUBFLOOR FOR FLOOR MATERIALS. - FRAME ALL 8'-0"h. INTERIOR NON-LOAD BEARING DOOR and BI-PASS DOOR HEADERS AT 99 1 4" OFF SUBFLOOR FOR , AND FLOOR MATERIALS. - FRAME ALL 6'-8"h. INTERIOR NON-LOAD BEARING DOOR and BI-PASS DOOR HEADERS AT 82 3 4" OFF SUBFLOOR FOR FLOOR MATERIALS. - FRAME ALL 6'-8"h. INTERIOR NON-LOAD BEARING DOOR and BI-PASS DOOR HEADERS AT 83 1 4" OFF SUBFLOOR FOR , AND FLOOR MATERIALS. - FRAME ALL OTHER 1st FLOOR & 2nd FLOOR ROOM OPENING HEADERS AT 93 1 4" OFF SUBFLOOR FOR FLOOR MATERIALS. - FRAME BI-PASS DOOR WIDTHS TO DIMENSIONS LABLED. - FRAME INTERIOR SINGLE SWING and DOUBLE SWING DOORS TO 2" WIDER THAN DOOR SIZE NOTED. - FRAME INTERIOR DOUBLE SWING DOORS w/ T-ASTRAGAL TO 3" WIDER THAN TOTAL DOOR SIZE NOTED. LEGEND - STRUCTURAL HEADERS and BEAMS: (1) 2x12 Header (2) 2x12 Header (2) 2x12 Header - w/ 12" Plywood Flitch (3) 2x12 Header (1) 2x10 Header (2) 2x10 Header (2) 2x10 Header - w/ 12" Plywood Flitch (3) 2x10 Header (1) 2x8 Header (2) 2x8 Header (2) 2x8 Header - w/ 12" Plywood Flitch (3) 2x8 Header (1) 13 4" x 111 4" LVL Header (2) 13 4" x 111 4" LVL Header (3) 13 4" x 111 4" LVL Header (4) 13 4" x 111 4" LVL Header (1) 13 4" x 91 4" LVL Header (2)1(3) 13 4" x 91 4" LVL Header (4) 13 4" x 91 4" LVL Header (1) 13 4" x 71 4" LVL Header (2) 13 4" x 71 4" LVL Header (3) 13 4" x 71 4" LVL Header (4) 13 4" x 71 4" LVL Header : Bold number identifies header type, small number in upper corner identifies # of jack studs on each side of header / beam. - No. of jack studs will vary - refer to plan. No. of Jack Studs, ea. side Header Type AP SYMBOLS LEGEND: * ALL DIMENSIONS ARE FRAME TO FRAME UNLESS SPECIFICALLY NOTED OTHERWISE ON THE PLANS. * ALL STUD WALLS TO BE 3 12" UNLESS NOTED OTHERWISE. - DENOTES SOLID BLOCKING TO BEARING - DENOTES 22" x 32" ATTIC ACCESS PANEL. 3'-212" 2860119 1 7'-10 1 4" 7'-10 1 4" 9080 B134R 111111PERGOLA (WING WALL) - REFER TO STANDARD WING WALL DTL. 01/WW1 1'-412"WALL OVEN5016P ABOVE 2816P ABOVE2816P ABOVE 9'-0"w. x 7'-0"h. SHORT PANEL CARRIAGE STYLE OH GARAGE DOOR w/ LONG SQUARE GRILLE GLASS INSERTS - INSULATED 16'-0"w. x 7'-0"h. SHORT PANEL CARRIAGE STYLE OH GARAGE DOORw/ LONG SQUARE GRILLE GLASS INSERTS-INSULATED 2'-6"x8'-0"INTERIOR DOOR NOTE ALL FIRST FLOOR INTERIOR DOORS ARE 8'-0" TALL EXCEPT THE GARAGE DOOR AT THE FAMILY FOYER 3'-0"x8'91 4" 4'-2 3 4" 9 14" 6 3 4" 914" 10'-6" 91 4" 63 4" 91 4"4'-3" 834" 634"5'-1" 2 2 2'-0" 11 2'-0"SET T/ 28/50/2860 WDW's @ 7'-9 14" OFF T/ 1st FLOOR SUBFLOOR SET T/ 28/50/2816P WDW's @ 10'-2 14" OFF T/ 1st FLOOR SUBFLOOR FRAMER'S NOTE: LINE OF SECOND FLOOR ABOVE (3) 2x4 JACK STUDS 2 1 1 2 1 1 (2) 2x6 JACK STUDS USE (2) 1 3/4" x 18" MICRO-LAM LVL's w/ SINGLE TOP PLATE - w/ (5) 2x4 JACK STUDS @ EACH END 7'-512"BRICK TO EDGE OF CONC.DETAIL - 12'-012" HARDWOOD HARDWOOD 6'-4" TO FACE OF HIP GIRDER TRUSS SEE DTL.02/A3.1SEE DTL. 02/A3.1 3'-412" 6'-812"OPENING3'-6"DN CARPET 4'-8 3 4" 3'-51 4" 2'-0" 2'-4"x8'1'-73 4" FLAT 2x4 BLK'G. FOR STORAGE BUILT-IN - SEE DTL. 02/A4.1 9'-3" 512" 6'-0" 6'-0"6'-0" COVERED PATIO 256 SQ FT EXPOSED AGGREGATE HANDRAIL 36" GAS COOKTOPNOTE: VENT MICROWAVE / RANGE HOOD TO EXTERIOR - PROVIDE 2x10 FLAT BLOCKING @ 60" A.F.F. PLUMBERS NOTE: PROVIDE GAS COOKTOP HOOK-UP 3'-4"2'-012"HB GAS GRILL R/I7'-434" 714" 7'-434" 714"7'-118" 714" 7'-118" 71 4"222222 22 PATIO 4 22 22 71 4" r = 6' - 0 " 17'-3" FLUSH BEAM NOTE: USE (1) 2x12 AS FLUSH BEAM - w/ (1) JACK STUD @ EACH END 5'-912"19'-5" 320 SQ FT EXPOSED AGGREGATE 1'-8"2'-6"x8'-0"GAS GRILL R/IREASON FOR PLOT: PLOT DATE: Job No. Sheet No.INNEW RESIDENCE FOR: HOMESITE NO. MASTER BY: DATE: C DATE: FISCHER HOMES INDIANAPOLIS LP6602 E 75TH ST SUITE 400INDIANAPOLIS IN 46250317.348.2500FIELD SPEC HOTLINE: (859) 344-7100COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc.JOB INFO: DATE: PHONE No: HOME TYPE: PLAN NO. EXTERIOR: 12/10/2018 3:18 PM OBF-071RAFAEL & ANNYMILIA BASSO14460 PEMBERTON LANEINGLENOOKG250AHOVERBROOK FARMS CARMEL, IN 46074071 ---- ---- 2016 859.344.3115 11/30/18 CHRISTINA BISHOPGRAND ESTATE COLLECTION fieldspecchange@fischerhomes.comREVISED BY: TEAM MANAGER:PHONE No:859.426.4223SHEZYRA SISKOWICA3.0 12/21/18 Mike Sheeks