Loading...
HomeMy WebLinkAboutC2.1 - Utility Plan Rev.01-04-19TOPOGRAPHIC & BOUNDARY NOTE ALL EXISTING HORIZONTAL AND VERTICAL INFORMATION HAS BEEN SHOWN PER AN ALTA/NSPS LAND TITLE SURVEY PREPARED BY CENTRAL STATES CONSULTING, LLC. DATED 10/01/2018; THEREFORE, CIVIL SITE GROUP, INC. CANNOT BE HELD RESPONSIBLE IF ACTUAL HORIZONTAL AND VERTICAL DATA IS DIFFERENT FROM THAT SHOWN ON THESE PLANS. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO COMMENCING WITH CONSTRUCTION. THESE DRAWINGS REFLECT ABOVE GROUND INDICATIONS OF EXISTING UTILITIES. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. UTILITY LOCATE NOTE INDIANA 811 FAILED TO LOCATE ALL EXISTING UTILITIES ON AND/OR SURROUNDING THE SUBJECT SITE; THEREFORE, CONTRACTOR IS RESPONSIBLE TO LOCATE AND FIELD VERIFY ANY EXISTING UTILITIES BEFORE COMMENCING WITH CONSTRUCTION. CIVIL SITE GROUP, INC. CANNOT BE HELD RESPONSIBLE IF THE PROPOSED IMPROVEMENTS INTERFERE WITH P.I.V. PRIVATE FIRE HYDRANT ANY EXISTING UTILITY INFORMATION NOT SHOWN ON THESE PLANS. j F. D. C. / / n ''w6'�P�C d ' wP\ER SER�CA W ''A q ° df+ ° UX' A4`1 51 . G. CATV: PROPERTY BOUNDARY Brighthouse Networks E - - RIGHT-OF-WAY SK4986@att.com -------- Fire Service: EASEMENT Office of Fire Chief, Fire Station #1 Carmel City Utilities Gary Hoyt John Duffy NORTH 760 Third Avenue SW Carmel, IN 46032 Carmel, IN 46032 (317) 571-2600 (317) 632-9077 cellison@carmel.in.gov ' .;',,.•;.:..:r. V Electric: PROPOSED CONCRETE 200 10 20 Carmel Street Department Rodney Johnson .. 1230 W. Morris Street 3400 West 131st Street Indianapolis, IN 46221 Westfield, IN 46074 (317) 261-5047 (317) 733-2001 ;^ LWE L L = ID 0 =U00 PROPOSED STORM SEWER ( IN FEET ) O Fg] 1 PROPOSED STORM STRUCTURE inch = 20 ft. UTILITY CROSSING (EXISTING UTILITY DEPTH UX UNKNOWN / CONTRACTOR TO FIELD VERIFY PRIOR TO COMMENCING WITH CONSTRUCTION) -_---_------ ROOF DRAIN - - - - - WTR— EXISTING UNDERGROUND WATER LINE - - - - - G \ EX. SANITARY MH \ RIM = 882.91 "1 \ \\ INV. (NW) = 873.40 \\ \\ - oErc - INV. (SE) \ \ = 873.57 ' / .,\" R TOPOGRAPHIC & BOUNDARY NOTE ALL EXISTING HORIZONTAL AND VERTICAL INFORMATION HAS BEEN SHOWN PER AN ALTA/NSPS LAND TITLE SURVEY PREPARED BY CENTRAL STATES CONSULTING, LLC. DATED 10/01/2018; THEREFORE, CIVIL SITE GROUP, INC. CANNOT BE HELD RESPONSIBLE IF ACTUAL HORIZONTAL AND VERTICAL DATA IS DIFFERENT FROM THAT SHOWN ON THESE PLANS. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO COMMENCING WITH CONSTRUCTION. THESE DRAWINGS REFLECT ABOVE GROUND INDICATIONS OF EXISTING UTILITIES. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. UTILITY LOCATE NOTE INDIANA 811 FAILED TO LOCATE ALL EXISTING UTILITIES ON AND/OR SURROUNDING THE SUBJECT SITE; THEREFORE, CONTRACTOR IS RESPONSIBLE TO LOCATE AND FIELD VERIFY ANY EXISTING UTILITIES BEFORE COMMENCING WITH CONSTRUCTION. CIVIL SITE GROUP, INC. CANNOT BE HELD RESPONSIBLE IF THE PROPOSED IMPROVEMENTS INTERFERE WITH P.I.V. PRIVATE FIRE HYDRANT ANY EXISTING UTILITY INFORMATION NOT SHOWN ON THESE PLANS. j F. D. C. / / n ''w6'�P�C d ' wP\ER SER�CA W ''A q ° df+ ° UX' A4`1 51 . G. CATV: PROPERTY BOUNDARY Brighthouse Networks E - - RIGHT-OF-WAY \\ \ a d. \ �d , a \ \ 6" WATER SERVICE LINE TAP °°• \ WITH VALVE PER CARMEL °``�\\� .�' ° n �;�' e'' \ \ UTILITIES STANDARDS \ \ \ ° /\ \ UX \ r \ \\ KISTING FIRE HYDRANT \ v Sk \\ S \N`I �S`O �QS 1 PMP\,\Np � \'� •�:�: d A' A d ° . .. � . : �^ 0� � I V 5-\�\ \C�$ Opp p \ � �' ° • e_ a � ° a SPS UX 0. \ o SECONDARY \ \ ELECTRIC \ \ SERVICE \ \ F \ 0A ° GAS SERVICE LINE 26 P`Ip (T.B.D. BY VECTREN) UX UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPER'S RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OR THE PROPOSED RIGHT-OF-WAY LINE. PROPOSED ELECTRIC TRANSFORMER PER IPL SPECS. G� PLAN NOTES: 1.5" INTERIOR SET METER ASSEMBLY PER OCARMEL UTILITIES STDS. / BACKFLOW PREVENTER TO BE FIRST CONNECTION DOWNSTREAM OF METER TREE (CONTRACTOR TO VERIFY ADEQUATE PRESSURE & FLOW PRIOR TO COMMENCING WITH CONSTRUCTION) UX UTILITY CROSSING PRIMARY ELECTRIC SERVICE (T.B.D. BY IPL) OWNER: FREDDY'S FROZEN CUSTARD & STEAKBURGERS ATTN: BLAKE EPPERSON (316) 617-8880 ENGINEER: CIVIL SITE GROUP, INC. 160 WEST CARMEL DRIVE SUITE 240 CARMEL, INDIANA 46032 (317) 810-1677 SURVEYOR: CENTRAL STATES CONSULTING, LLC. 23—B NORTH GREEN STREET BROWNSBURG, INDIANA 46112 (317) 858-8662 ARCHITECT: WINTER ARCHITECTS ATTN: RODGER BAKER 1024 EAST 1st STREET WICHITA, KS 67214 (316) 267-6224 \ \ \ EX. SANITARY MH \\ RIM = 882.48V\ -1711 \ / INV. NW = 874.03 •::�:r '. cS�� '� p\1�\p\(�( �..t INV. SE 874.14 \ INV. (NE) = 874.14*�"�':' r• fr \ *PROPOSED CONNECTION* REVISION RECORD REV DATE DESCRIPTION DES BY APP BY 1 01/04/19 REVISIONS PER T.A.C. AGENCY COMMENTS EAG EAG IRRIGATION NOTE SITE IRRIGATION IS NOT SHOWN ON THESE PLANS. IF SITE IRRIGATION IS REQUIRED, CONTRACTOR SHALL WORK WITH THE LOCAL WATER UTILITY TO DETERMINE THE REQUIREMENTS & LOCATION FOR THE IRRIGATION METER & SITE IRRIGATION SYSTEM. NO IRRIGATION SYSTEM SHALL BE INSTALLED WITHIN THE PUBLIC RIGHT-OF-WAY UNLESS APPROVAL FROM THE CITY OF GREENWOOD BOARD OF PUBLIC WORKS AND SAFETY IS OBTAINED. UTILITY VALVE NOTE ALL UTILITY VALVES AFFECTED BY CONSTRUCTION SHALL BE ADJUSTED TO FINAL GRADE AS NEEDED TO BE FLUSH WITH FINISHED PAVEMENT, SIDEWALK OR LANDSCAPE AREA. NOTE 18" OF VERTICAL SERARATION MUST BE MAINTAINED FOR ALL UTILITY CROSSINGS. *THROUGH BENCHWALL*G •:r \.;r:'': \\� °°° / / / ° : 13 _ SITE LIGHTING NOTE SITE LIGHTING IS NOT SHOWN ON THESE PLANS. •, � J; 4" ., \\ � • l: ; ..: / � / G .- � _ �. 0 2-1Ya CONDUITS (SITE LIGHTING &SECURITY) • ,,, ..; : \ ��.:.';;,:,, \ / / - \ / REQUIRED TO ALL SITE LIGHTING LOCATIONS. \ / /. ..* %'.•.• :�'' �,' .� :" 130 °� � �� ,� .° ... ' o / -'r EXISTING 16" POLY WATERMAIN (CARMEL UTILITIES) ,:•: \\ \ / / _ __ **NOT LOCATED ON SURVEY, CONTRACTOR TO FIELD \ / / •�: ' 'GAS M ° CONNECT TO EXISTING • • VERIFY LOCATION & DEPTH PRIOR TO COMMENCING GAS MAIN \ WITH CONSTRUCTION** \ \ \\ r / / 'r,`. r:• :,�:'' - - / -(T.B.D. BY VECTREN) •;:' ; `•• ::, : :. / / \ .:: •a .: _ - % o / / C, NS vwN EPS / EXISTING FIRE HYDRANT G 5p s�VIV o R/W GRADING, DRAINAGE, & UTILITY NOTE / a \\ / SANITARY LATERAL NOTE EX. SANITARY MH �:�: \\ \\ CONTRACTOR PERMIT(S) NOTES I RIM = 882.78 '� . •> \\ \ INV. (NW) = 874.99 1. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED \ STORM WATER MANAGEMENT PERMIT. �+ r 2. CONTRACTOR RESPONSIBLE TO OBTAIN ALL R/W PERMITS FROM INDOT & Know whaft below. Va befom jjoudig. \\ PROVIDE TRAFFIC CONTROL AS NEEDED. •: A : • %, UTILITY NOTES 1. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO THEIR PHASE OF WORK. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATIONS FOR EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED. 2. STANDARD SPECIFICATIONS FOR THE LOCAL GOVERNING AGENCY SHALL APPLY FOR ALL SANITARY SEWERS, STORM SEWERS, AND WATER MAINS. 3. ANY PART OF THE SANITARY OR STORM SEWER TRENCHES RUNNING UNDER PAVED AREAS TO BE BACKFILLED WITH GRANULAR MATERIAL. 4. ALL WATER SERVICE / FIRE LINES ARE REQUIRED TO HAVE A 54" MINIMUM COVER OVER TOP OF PIPE. ALL WATER/SANITARY LINE CROSSINGS MUST MAINTAIN 18" VERTICAL SEPARATION BETWEEN OUTSIDE OF PIPES PER INDIANA STATE DEPARTMENT OF HEALTH. 5. STERILIZATION OF WATER MAIN SHALL BE IN ACCORDANCE WITH STATE BOARD OF HEALTH REQUIREMENTS. (APPLIES TO COMMERCIAL ONLY) 6. CONTRACTOR RESPONSIBLE TO INSTALL ALL UNDERGROUND CONDUIT PER UTIITY COMPANY'S SPECIFICATIONS. 7. CONTRACTOR RESPONSIBLE FOR RESTORATION TO ALL AREAS AFFECTED DURING CONSTRUCTION. REFER TO THE CITY OF NOBLESVILLE STANDARDS FOR RESTORATION REQS. 8. CONTRACTOR TO LOCATE ALL EXISTING UTLITIES AT ANY PROPOSED CROSSING AND PROVIDE EXISTING TOP OF PIPE ELEVATIONS WITHIN 10 DAYS OF NOTICE TO PROCEED. PROVIDE CONCRETE CRADLE AS REQUIRED FOR ANY VERTICAL SEPARATION LESS THAN 18 INCHES. UTILITY CONTACTS Natural Gas: Vectren Energy Joanie Clark (317) 776-5532 jlclark@Vectren.com Sanitary Sewer: TriCo Regional Sewer Utility Ryan Hartman 10701 N. College Avenue, Ste. A Indianapolis, IN 46280 (317) 844-9200 ext. 203 Drainage: Carmel Engineering Alex Jordan or John Thomas 1 Civic Square Carmel, IN 46032 (317) 571-2441 gduncan@carmel.in.gov Telephone: CATV: PROPERTY BOUNDARY Brighthouse Networks Steve Krebs - - RIGHT-OF-WAY SK4986@att.com -------- Fire Service: EASEMENT Office of Fire Chief, Fire Station #1 Carmel City Utilities Gary Hoyt John Duffy NORTH 760 Third Avenue SW Carmel, IN 46032 Carmel, IN 46032 (317) 571-2600 (317) 632-9077 cellison@carmel.in.gov ' .;',,.•;.:..:r. V Electric: PROPOSED CONCRETE 200 10 20 Carmel Street Department Rodney Johnson .. 1230 W. Morris Street 3400 West 131st Street Indianapolis, IN 46221 Westfield, IN 46074 (317) 261-5047 (317) 733-2001 ;^ LWE L L = ID 0 =U00 PROPOSED STORM SEWER ( IN FEET ) O Fg] 1 PROPOSED STORM STRUCTURE inch = 20 ft. UTILITY CROSSING (EXISTING UTILITY DEPTH UX UNKNOWN / CONTRACTOR TO FIELD VERIFY PRIOR TO COMMENCING WITH CONSTRUCTION) -_---_------ ROOF DRAIN - - - - - WTR— EXISTING UNDERGROUND WATER LINE - - - - - G EXISTING UNDERGROUND GAS LINE EXISTING UNDERGROUND TELECOM LINE EXISTING UNDERGROUND ELECTRIC LINE EXISTING OVERHEAD ELECTRIC & TELECOM - - - - - - oErc - EXISTING OVERHEAD ELECTRIC, TELECOM, & CABLE - - - - - of - EXISTING ELECTRIC E E PROPOSED ELECTRIC SERVICE T T PROPOSED TELECOM SERVICE W PROPOSED WATER SERVICE W G G PROPOSED GAS SERVICE C.O.PROPOSED SANITARY LATERAL WITH CLEANOUTS (SEE TRICO/CTRWD DETAIL ON SHEET C10.2) IRRIGATION NOTE SITE IRRIGATION IS NOT SHOWN ON THESE PLANS. IF SITE IRRIGATION IS REQUIRED, CONTRACTOR SHALL WORK WITH THE LOCAL WATER UTILITY TO DETERMINE THE REQUIREMENTS & LOCATION FOR THE IRRIGATION METER & SITE IRRIGATION SYSTEM. NO IRRIGATION SYSTEM SHALL BE INSTALLED WITHIN THE PUBLIC RIGHT-OF-WAY UNLESS APPROVAL FROM THE CITY OF GREENWOOD BOARD OF PUBLIC WORKS AND SAFETY IS OBTAINED. UTILITY VALVE NOTE ALL UTILITY VALVES AFFECTED BY CONSTRUCTION SHALL BE ADJUSTED TO FINAL GRADE AS NEEDED TO BE FLUSH WITH FINISHED PAVEMENT, SIDEWALK OR LANDSCAPE AREA. NOTE 18" OF VERTICAL SERARATION MUST BE MAINTAINED FOR ALL UTILITY CROSSINGS. *THROUGH BENCHWALL*G •:r \.;r:'': \\� °°° / / / ° : 13 _ SITE LIGHTING NOTE SITE LIGHTING IS NOT SHOWN ON THESE PLANS. •, � J; 4" ., \\ � • l: ; ..: / � / G .- � _ �. 0 2-1Ya CONDUITS (SITE LIGHTING &SECURITY) • ,,, ..; : \ ��.:.';;,:,, \ / / - \ / REQUIRED TO ALL SITE LIGHTING LOCATIONS. \ / /. ..* %'.•.• :�'' �,' .� :" 130 °� � �� ,� .° ... ' o / -'r EXISTING 16" POLY WATERMAIN (CARMEL UTILITIES) ,:•: \\ \ / / _ __ **NOT LOCATED ON SURVEY, CONTRACTOR TO FIELD \ / / •�: ' 'GAS M ° CONNECT TO EXISTING • • VERIFY LOCATION & DEPTH PRIOR TO COMMENCING GAS MAIN \ WITH CONSTRUCTION** \ \ \\ r / / 'r,`. r:• :,�:'' - - / -(T.B.D. BY VECTREN) •;:' ; `•• ::, : :. / / \ .:: •a .: _ - % o / / C, NS vwN EPS / EXISTING FIRE HYDRANT G 5p s�VIV o R/W GRADING, DRAINAGE, & UTILITY NOTE / a \\ / SANITARY LATERAL NOTE EX. SANITARY MH �:�: \\ \\ CONTRACTOR PERMIT(S) NOTES I RIM = 882.78 '� . •> \\ \ INV. (NW) = 874.99 1. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED \ STORM WATER MANAGEMENT PERMIT. �+ r 2. CONTRACTOR RESPONSIBLE TO OBTAIN ALL R/W PERMITS FROM INDOT & Know whaft below. Va befom jjoudig. \\ PROVIDE TRAFFIC CONTROL AS NEEDED. •: A : • %, UTILITY NOTES 1. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO THEIR PHASE OF WORK. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATIONS FOR EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED. 2. STANDARD SPECIFICATIONS FOR THE LOCAL GOVERNING AGENCY SHALL APPLY FOR ALL SANITARY SEWERS, STORM SEWERS, AND WATER MAINS. 3. ANY PART OF THE SANITARY OR STORM SEWER TRENCHES RUNNING UNDER PAVED AREAS TO BE BACKFILLED WITH GRANULAR MATERIAL. 4. ALL WATER SERVICE / FIRE LINES ARE REQUIRED TO HAVE A 54" MINIMUM COVER OVER TOP OF PIPE. ALL WATER/SANITARY LINE CROSSINGS MUST MAINTAIN 18" VERTICAL SEPARATION BETWEEN OUTSIDE OF PIPES PER INDIANA STATE DEPARTMENT OF HEALTH. 5. STERILIZATION OF WATER MAIN SHALL BE IN ACCORDANCE WITH STATE BOARD OF HEALTH REQUIREMENTS. (APPLIES TO COMMERCIAL ONLY) 6. CONTRACTOR RESPONSIBLE TO INSTALL ALL UNDERGROUND CONDUIT PER UTIITY COMPANY'S SPECIFICATIONS. 7. CONTRACTOR RESPONSIBLE FOR RESTORATION TO ALL AREAS AFFECTED DURING CONSTRUCTION. REFER TO THE CITY OF NOBLESVILLE STANDARDS FOR RESTORATION REQS. 8. CONTRACTOR TO LOCATE ALL EXISTING UTLITIES AT ANY PROPOSED CROSSING AND PROVIDE EXISTING TOP OF PIPE ELEVATIONS WITHIN 10 DAYS OF NOTICE TO PROCEED. PROVIDE CONCRETE CRADLE AS REQUIRED FOR ANY VERTICAL SEPARATION LESS THAN 18 INCHES. UTILITY CONTACTS Natural Gas: Vectren Energy Joanie Clark (317) 776-5532 jlclark@Vectren.com Sanitary Sewer: TriCo Regional Sewer Utility Ryan Hartman 10701 N. College Avenue, Ste. A Indianapolis, IN 46280 (317) 844-9200 ext. 203 Drainage: Carmel Engineering Alex Jordan or John Thomas 1 Civic Square Carmel, IN 46032 (317) 571-2441 gduncan@carmel.in.gov Telephone: CATV: AT&T Brighthouse Networks Steve Krebs Jason Kirkman (317) 252-4275 (317) 632-9077 x291 SK4986@att.com jason.kirkman@mybrighthouse.com Fire Service: Water: Office of Fire Chief, Fire Station #1 Carmel City Utilities Gary Hoyt John Duffy Two Civic Square 760 Third Avenue SW Carmel, IN 46032 Carmel, IN 46032 (317) 571-2600 (317) 632-9077 cellison@carmel.in.gov V Electric: Streets: Indianapolis Power & Light Company Carmel Street Department Rodney Johnson Dave Klingensmith 1230 W. Morris Street 3400 West 131st Street Indianapolis, IN 46221 Westfield, IN 46074 (317) 261-5047 (317) 733-2001 ;^ P G L ESS G 44/ No s PE10403858 e = STATE OF 00 0 -I, ,off '4I� SS�O N AL ENG��`, 6- T DATE: 10/26/2018 DWN BY: EAG CHKD. BY: EAG SCALE: 1 " = 20' DATE: 10/26/18 tCn CN y� �U) C C �—w'� Q V C / i O CO 0 C8 t- Ctx Hn� t 1 v � w O N CO � tO �0 V F-�-I PROJECT NUMBER WAX.001 DRAWING NUMBER C2.1 SHEET 4 OF 27 U - z (L O C� 0) 0 V 00 Zo � N U)�o O N > p 0 ;^ LWE L L = ID 0 =U00 U W P G L ESS G 44/ No s PE10403858 e = STATE OF 00 0 -I, ,off '4I� SS�O N AL ENG��`, 6- T DATE: 10/26/2018 DWN BY: EAG CHKD. BY: EAG SCALE: 1 " = 20' DATE: 10/26/18 tCn CN y� �U) C C �—w'� Q V C / i O CO 0 C8 t- Ctx Hn� t 1 v � w O N CO � tO �0 V F-�-I PROJECT NUMBER WAX.001 DRAWING NUMBER C2.1 SHEET 4 OF 27