Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
C4.0 - INDOT Detailed Entrance Plan
r-- \ \ I \\ PLAN NOTES: TAPER CURB FLUSH WITH PAVEMENT FLUSH WITH PAVEMENT \ 882.98 \ \ \ \ \ 882.48 M.E. \ \ \ \ 882.32- \ 882.32 M.E. / \\ \\ \ TBM #50 \ \ CSC CUT „X„ \\ \ ELEV.=882.35' a \ \ \ \ \\ i\\ 883.96 0 \ I 882.00 �� / - �\� � �� � �.` � `' 883.4 f 1 \ \\ M.E. 881.36 r \ .".•�cbq�wLl 883.81 883.31 883.74 aa4 92 -60y\ i 883.57 GRADE T 9 \ BREAK 883.43 \ ° ° 3.43 884.07 O M.E. 881.46' \ 883.71 r rn 4 \ a FI 881.61 �(\\ . \ .. . �� 832 883.21 .•.r: . a 8813 FIM.E. 881.51 d . \.A F8-83-..0-21 FL �:;...... �...... CROOS-SLOPE NOT . � a \\ '..`:... / aa�o5 � '•::�..'.:_ .:.. IU EXCEED 2.0% 881.1 \\ /. age 4a 884.24 / 0 M.E. 881.58 O�/ 1 o - �• o� q0 l i \ \ Ale- A, \ \ \ y aa� D .. \ \882.18 \ � w M.E. 881.51 \ O \ \ \\ ®\ 883.82 \ \7� \ \ \ 883.82 d /* GRPQ K 1 \ \ \\ \\\ __-UT aa� \ \\ \a \\\ \\ \cp aa�20 \ IND 1 \ \ 1 \ $ G 03 UA r wv PROPOSED GRADING & DRAINAGE PLAN NOTES: PROPOSED DRIVE & SIDEWALK / CONNECTION PENDING APPROVAL FROM ADJACENT LAND OWNER / d p. � •' At / d d a . a ' 0 • Ik 31' M c\ PSS M Q 5 • .�, a d d. \. B a \f��x ....;� om M � 0 \ a o� \ S \ \\ ---Ur -11) \� d \\ \ T 00 \ �\ G \ PROPOSED LAYOUT, GEOMETRY, & STRIPING © INDOT CLASS III CONCRETE DRIVEWAY. SEE INDOT STD. DWG. DETAIL E -610 -DRV -03 ON SHEET C10.1 OINSTALL INDOT "ONE WAY" SIDEWALK CURB RAMP SEE INDOT STD. DWG DETAILS E-604-SWCR-05 & E-604-SWCR-06 ON SHEET C10.1. OMONOLITHIC CONCRETE CURB & GUTTER PER INDOT CLASS III DRIVE SPECS. SEE INDOT STD. DWG. DETAIL E-605-CCCG-01 ON SHEET C10.1 OS CONCRETE SIDEWALK. REFER TO CARMEL STD. DWG. 10-18 ON SHEET C10.0 REVISION RECORD REVI DATE DESCRIPTION OWNER: PROPERTY BOUNDARY RIGHT-OF-WAY PROPOSED CONCRETE FREDDY'S FROZEN CUSTARD & STEAKBURGERS ATTN: BLAKE EPPERSON (316) 617-8880 ENGINEER: CIVIL SITE GROUP, INC. 160 WEST CARMEL DRIVE SUITE 240 CARMEL, INDIANA 46032 (317) 810-1677 SURVEYOR: CENTRAL STATES CONSULTING, LLC. 23-B NORTH GREEN STREET BROWNSBURG, INDIANA 46112 (317) 858-8662 ARCHITECT: WINTER ARCHITECTS ATTN: RODGER BAKER 1024 EAST 1st STREET WICHITA, KS 67214 (316) 267-6224 DES BYIAPP BYI NORTH 20 0 10 20 ( IN FEET ) 1 inch= 20 ft. INDOT STANDARD DETAILS ALL APPLICABLE INDOT STANDARD DRAWING DETAILS CAN BE FOUND ON SHEET C10.1. HANDICAP RAMP NOTE ALL HANDICAP RAMPS CONSTRUCTED WITHIN THE PUBLIC RIGHT-OF-WAY SHALL COMPLY WITH STANDARD I.N.D.O.T. DETAILS. MICHIGAN ROAD (U.S. 421) TRAFFIC CONTROL CONTRACTOR SHALL ADHERE TO ALL CURRENT INDOT & CITY OF CARMEL STANDARDS RELATED TO WORK WITHIN THE RIGHT-OF-WAY INCLUDING LANE CLOSURES, TEMPORARY TRAFFIC CONTROL, PLACEMENT OF WORK ZONE BARRICADES DURING ACTIVE & INACTIVE WORK PERIODS, WORK ZONE HOURS, APPLICABLE CONSTRUCTION SIGN POSTING BEFORE / WITHIN / AFTER THE WORK ZONE. CONTRACTOR'S RIGHT-OF-WAY PERMIT OBTAINED FROM INDOT SHALL GOVERN ALL MAINTENANCE OF TRAFFIC REQUIREMENTS. UTILITY LOCATE NOTE INDIANA 811 FAILED TO LOCATE ALL EXISTING UTILITIES ON AND/OR SURROUNDING THE SUBJECT SITE; THEREFORE, CONTRACTOR IS RESPONSIBLE TO LOCATE AND FIELD VERIFY ANY EXISTING UTILITIES BEFORE COMMENCING WITH CONSTRUCTION. CIVIL SITE GROUP, INC. CANNOT BE HELD RESPONSIBLE IF THE PROPOSED IMPROVEMENTS INTERFERE WITH ANY EXISTING UTILITY INFORMATION NOT SHOWN ON THESE PLANS. TOPOGRAPHIC & BOUNDARY NOTE ALL EXISTING HORIZONTAL AND VERTICAL INFORMATION HAS BEEN SHOWN PER AN ALTA/NSPS LAND TITLE SURVEY PREPARED BY CENTRAL STATES CONSULTING, LLC. DATED 10/01/2018; THEREFORE, CIVIL SITE GROUP, INC. CANNOT BE HELD RESPONSIBLE IF ACTUAL HORIZONTAL AND VERTICAL DATA IS DIFFERENT FROM THAT SHOWN ON THESE PLANS. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO COMMENCING WITH CONSTRUCTION. THESE DRAWINGS REFLECT ABOVE GROUND INDICATIONS OF EXISTING UTILITIES. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. z w W CV I� www ~C/)� CODo 00 r+ o C/)Qft N U) o � Ww� 0 (0 a� �Nx oC: - W�=O M U ♦� V � NO s PE10403858 e = STATE OF o DATE: 10/26/2018 tV S CN W V CV �Oc� � O C ct �-x � W ) Q fix~ W NCO ps W O� n ISI \ 0 G� PROJECT NUMBER WAX.001 DRAWING NUMBER C4.0 SHEET 10 OF 27 DWN BY: KPB CHKD. BY: EAG SCALE: 1 to = 20' DATE: 10/26/18