HomeMy WebLinkAboutG001 Cover SheetG-001C:\Users\ejd\AppData\Local\Microsoft\Windows\INetCache\IE\BQ5OJ514\HENRY GARAGE.pln
EVAN J. DENIS DESIGN
evandenis1@yahoo.com
317-900-6685, #Contact State #Contact Postcode
Cover Sheet
12/2/2018SCHNEIDER GARAGE REBUILD
HENRY SCHNEIDER
SHEET INDEX
General Drawings
Floor Plans
Elevations
Sections
G-001
A-101
A-201
A-301
A-302
Cover Sheet
First Floor Plan
Exterior Elevations
Building Sections
Building Sections
30'-0"11'-0"4'-0"
3 SITE PLAN 1/32" = 1'-0"
SCHNEIDER GARAGE REBUILD
PROJECT DESCRIPTION:
THIS PROJECT IS TO REBUILD A DETACHED GARAGE THAT BURNED IN A
RECENT FIRE. THE CONCRETE FOUNDATION AND SLAB, AS WELL AS THE
ELECTRICAL PANEL WERE UNHARMED DURING THE FIRE, AND WILL BE
REUSED. THE WALLS WILL BE 10' TALL 2X4 STUDS 16" O.C., WITH 1/2" OSB
SHEATHING, BUILDING WRAP, AND CEMENT BOARD SIDING. THERE WILL BE
A PRESSURE TREATED SILL PLATE GLUED AND BOLTED TO FOUNDATION,
AND A DOUBLE TOP PLATE. THE ROOF STRUCTURE WILL BE PRE-
MANUFACTURED ENGINEERED TRUSSES, W/ 3/4" OSB DECKING. FELT PAPER
AND ARCHITECTURAL ASPHALT SHINGLES. TRUSSES WILL BE CONNECTED
TO WALL AND BRACED TOGETHER PER MANUFACTURER'S INSTRUCTION.
ATTIC WILL BE VENTILATED WITH CONT. SOFFIT VENTS AND CONT. RIDGE
VENT.
10129 GUILFORD AVE.
INDIANAPOLIS, IN 46280
5'-0"
01/03/19
Mike Sheeks