Loading...
HomeMy WebLinkAboutSchnieder Garage RebuildG-001C:\Users\ejd\AppData\Local\Microsoft\Windows\INetCache\IE\BQ5OJ514\HENRY GARAGE.pln EVAN J. DENIS DESIGN evandenis1@yahoo.com 317-900-6685, #Contact State #Contact Postcode Cover Sheet 12/2/2018SCHNEIDER GARAGE REBUILD HENRY SCHNEIDER SHEET INDEX General Drawings Floor Plans Elevations Sections G-001 A-101 A-201 A-301 A-302 Cover Sheet First Floor Plan Exterior Elevations Building Sections Building Sections 30'-0"11'-0"4'-0" 3 SITE PLAN 1/32" = 1'-0" SCHNEIDER GARAGE REBUILD PROJECT DESCRIPTION: THIS PROJECT IS TO REBUILD A DETACHED GARAGE THAT BURNED IN A RECENT FIRE. THE CONCRETE FOUNDATION AND SLAB, AS WELL AS THE ELECTRICAL PANEL WERE UNHARMED DURING THE FIRE, AND WILL BE REUSED. THE WALLS WILL BE 10' TALL 2X4 STUDS 16" O.C., WITH 1/2" OSB SHEATHING, BUILDING WRAP, AND CEMENT BOARD SIDING. THERE WILL BE A PRESSURE TREATED SILL PLATE GLUED AND BOLTED TO FOUNDATION, AND A DOUBLE TOP PLATE. THE ROOF STRUCTURE WILL BE PRE- MANUFACTURED ENGINEERED TRUSSES, W/ 3/4" OSB DECKING. FELT PAPER AND ARCHITECTURAL ASPHALT SHINGLES. TRUSSES WILL BE CONNECTED TO WALL AND BRACED TOGETHER PER MANUFACTURER'S INSTRUCTION. ATTIC WILL BE VENTILATED WITH CONT. SOFFIT VENTS AND CONT. RIDGE VENT. 10129 GUILFORD AVE. INDIANAPOLIS, IN 46280 5'-0" 01/03/19 Mike Sheeks A-101C:\Users\ejd\AppData\Local\Microsoft\Windows\INetCache\IE\BQ5OJ514\HENRY GARAGE.pln EVAN J. DENIS DESIGN evandenis1@yahoo.com 317-900-6685, #Contact State #Contact Postcode First Floor Plan 12/2/2018SCHNEIDER GARAGE REBUILD HENRY SCHNEIDER D-01 9'-0"16'-0"D-027'-0"3'-0"35'-11"23'-5"1'-8" 16'-0 1/2" 1'-8" 3'-2 1/2" 10"23'-5"1A-3011A-3011A-3021A-3023A2012A-2011A-2014A201LEAVE OPENING INTRUSSES ABOVE FORFUTURE ATTIC ACCESS1 First Floor Plan 1/4" = 1'-0"01/03/19 Mike Sheeks A-201C:\Users\ejd\AppData\Local\Microsoft\Windows\INetCache\IE\BQ5OJ514\HENRY GARAGE.pln EVAN J. DENIS DESIGN evandenis1@yahoo.com 317-900-6685, #Contact State #Contact Postcode Exterior Elevations 12/2/2018SCHNEIDER GARAGE REBUILD HENRY SCHNEIDER First Floor ±0" ROOF +10'-7 1/8" EXISTING CONCRETE FOUNDATION D.S. 1X4 TRIM 1X8 FASCIA BD. ALUM. GUTTER ARCH. ASPHALT SHINGLES ALUM. DRIP EDGE CEMENT BD. SIDING CONT. RIDGE VENT 1X4 TRIM EXISTING CONCRETE FOUNDATION D.S. 1X4 TRIM 1X8 GUTTER BD. ALUM. GUTTER ARCH. ASPHALT SHINGLES ALUM. DRIP EDGE CEMENT BD. SIDING CONT. RIDGE VENT First Floor ±0" ROOF +10'-7 1/8" EXISTING CONCRETE FOUNDATION D.S. 1X4 TRIM 1X8 FASCIA BD. ALUM. GUTTER ARCH. ASPHALT SHINGLES ALUM. DRIP EDGE CEMENT BD. SIDING CONT. RIDGE VENT 1X4 TRIM 3x7 DOOR W 2' TRANSOM 16x9 O.H. DOOR EXISTING CONCRETE FOUNDATION D.S. 1X4 TRIM 1X8 GUTTER BD. ALUM. GUTTER ARCH. ASPHALT SHINGLES ALUM. DRIP EDGE CEMENT BD. SIDING CONT. RIDGE VENT 1 EAST Elevation 3/16" = 1'-0"2 SOUTH Elevation 3/16" = 1'-0" 3 WEST Elevation 3/16" = 1'-0"4 NORTH Elevation 3/16" = 1'-0" 01/03/19 Mike Sheeks A-301C:\Users\ejd\AppData\Local\Microsoft\Windows\INetCache\IE\BQ5OJ514\HENRY GARAGE.pln EVAN J. DENIS DESIGN evandenis1@yahoo.com 317-900-6685, #Contact State #Contact Postcode Building Sections 12/2/2018SCHNEIDER GARAGE REBUILD HENRY SCHNEIDER -4'-0" -4'-0" ±0" First Floor ±0" First Floor +10'-7 1/8" ROOF +10'-7 1/8" ROOF 6"1 1/2" 9'-8 5/8" PRECUT 10' 2X4 3" 7'-2 1/64"1'-0"17'-9 9/64"CONT. RIDGE VENT ARCH. ASPHALT SHINGLES OVER FELT PAPER OVER 3/4" PLYWOOD DECKING PREMANUFACTURED WOOD TRUSS @ 24" O.C., LEAVE AREA IN MIDDLE AS OPEN AS POSSIBLE FOR ATTIC STORAGE. ATTACH AND BRACE ACCORDING TO SUPPIER'S INSTRUCTIONS. DOUBLE 2X4 TOP PLATE PLYWOOD SOFFIT WITH CONT. VENT PREFIN. ALUM. DRIP EDGE 4" PREFIN. ALUM. GUTTET ATTACHED ON 1X8 WD GUTTER BOARD CEMENT BD. SIDING OVER BUILDING WRAP OVER 5/8" PLYWOOD SHEATHING OVER 2X4 STUD WALL @ 16" O.C. EXISTING 4" WIDE CONCRETE STEM WALL EXISTING CONCRETE SLAB AND FOUNDATION P.T. 2X4 SILL PLATE IN BED OF SEALANT AND BOLTED TO CONCRETE WALL W/ EXISTING ANCHOR BOLTS 7 12 1X4 WD. TRIM 1 Building Section A 01/03/19 Mike Sheeks A-302C:\Users\ejd\AppData\Local\Microsoft\Windows\INetCache\IE\BQ5OJ514\HENRY GARAGE.pln EVAN J. DENIS DESIGN evandenis1@yahoo.com 317-900-6685, #Contact State #Contact Postcode Building Sections 12/2/2018SCHNEIDER GARAGE REBUILD HENRY SCHNEIDER " r " F 1'-4" SCREW AND BOLT 2X6 LADDER TRUSS FOR GABLE END SOFFITS CONT. RIDGE VENT ARCH. ASPHALT SHINGLES OVER FELT PAPER OVER 3/4" OSB DECKING PREMANUFACTURED WOOD TRUSS @ 24" O.C., LEAVE AREA IN MIDDLE AS OPEN AS POSSIBLE FOR ATTIC STORAGE. ATTACH AND BRACE ACCORDING TO SUPPIER'S INSTRUCTIONS. TRUSSES TO BE LOADED FOR 30PSF DOUBLE 2X4 TOP PLATE PLYWOOD SOFFIT WITH CONT. VENT 1x8 WD FASCIA BD CEMENT BD. SIDING OVER BUILDING WRAP OVER 5/8" PLYWOOD SHEATHING OVER 2X4 STUD WALL @ 16" O.C. EXISTING 4" WIDE CONCRETE STEM WALL EXISTING CONCRETE SLAB AND FOUNDATION P.T. 2X4 SILL PLATE IN BED OF SEALANT AND BOLTED TO CONCRETE WALL W/ EXISTING ANCHOR BOLTS 1X4 WD. TRIM INFILL 2X4 STUDS AT GABLE ENDS DOUBLE 2X12 HEADER 1 Building Section A 3/8" = 1'-0" 01/03/19 Mike Sheeks