HomeMy WebLinkAboutA000.2TOP OF FOUNDATION TOP OF FLOOR TOP OF PLATE WINDOW HEAD HGT. WINDOW HEAD HGT. TOP OF PLATE TOP OF FLOOR \A1;10'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"128 ROOF SHINGLES, PER SPEC HORIZONTAL SIDING, PER SPEC 6" FASCIA BOARD, PER SPEC 4" STONE SILL, PER SPECSTONE VENEER, PER SPEC 4" CORNER BOARD, PER SPEC 6" TRIM, PER SPEC HORIZONTAL SIDING, PER SPEC 4" TRIM, PER SPECHORIZONTAL SIDING, PER SPEC ROOF SHINGLES, PER SPEC 4:12 3" TRIM OVER 10" FRIEZE BOARD, PER SPEC 1212 1212 10" BAND, PER SPEC 1212 METAL ROOF, PER SPEC \A1;2'-2{\H0.750000x;\S3#8;}"\A1;TYP. FYPON BKT10x16x14 OR APPROVED EQUAL 3" FASCIA, PER SPEC \A1;9'-1{\H0.750000x;\S1#8;}"\A1;PLATE HEIGHT \A1;2'-8" \A1;8'-0" 128 \A1;4'-0" \A1;8'-0" \A1;9{\H0.750000x;\S1#2;}"\A1;TYP 1x4 TRIM, PER SPEC +12+11+12 SMOOTH PANEL, PER SPEC 8" TRIM, PER SPEC6" TRIM, PER SPEC SCALE:FRONT ELEVATION1/4" = 1'-0" 124 \A1;17'-3" \A1;2'-0" SCALE:REAR ELEVATION1/8" = 1'-0"- 128 128 126 128\A1;2'-8"\A1;8'-0" SCALE:LEFT ELEVATION1/8" = 1'-0"- TOP OF FOUND. TOP OF PLATE TOP OF PLATE \A1;10'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" 128128 \A1;2'-8"\A1;8'-0" 128 SCALE:RIGHT ELEVATION1/8" = 1'-0"- \A1;1'-0"\PTYP.\A1;1'-0"\PTYP. \A1;1'-0"\PTYP. \A1;1'-0"\PTYP. \A1;1'-0"\PTYP.\A1;1'-0"\PTYP. \A1;1'-0"\PTYP. \A1;16'-0" \A1;4'-0" PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION \A1;7'-0" \A1;6'-0" \A1;6'-0" \A1;6'-0"\A1;6'-0" \A1;1'-0"\PTYP. MIN. 177 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "E" SCALE:ROOF PLAN1/8" = 1'-0"- 8:12 8:12 8:12 8:128:12 12:12 ROOF AREASQ. FT."A"2307 ROOF AREASQ. FT."B"311 ROOF AREASQ. FT."C"323 ROOF AREASQ. FT."D"139 12:124:12 6:12 6:12 12:1212:12 4:124:12 8:128:12 6:12 ELEVATION NC3G ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 2308 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 3.08 3.85 3.81 47.78 9 0 AT EAVE 4.62 3.85 4.17 52.22 0 60.00 TOTAL (MIN)7.69 7.69 7.98 100.00 3 HIGH - RIDGE VENT 3.08 3.85 3.88 48.61 0 0 31.00 AT EAVE 4.62 3.85 4.10 51.39 0 59.00 TOTAL (MIN)7.69 7.69 7.97 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION NC3G ROOF AREA "B"SQ FTG 311 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.41 0.52 0.85 48.41 2 0 AT EAVE 0.62 0.52 0.90 51.59 0 13.00 TOTAL (MIN)1.04 1.04 1.75 100.00 3 HIGH - RIDGE VENT 0.41 0.52 0.88 49.22 0 0 7.00 AT EAVE 0.62 0.52 0.90 50.78 0 13.00 TOTAL (MIN)1.04 1.04 1.78 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION NC3G ROOF AREA "C"SQ FTG 139 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.19 0.23 0.00 0.00 0 0 AT EAVE 0.28 0.23 0.42 100.00 0 6.00 TOTAL (MIN)0.46 0.46 0.42 100.00 3 HIGH - RIDGE VENT 0.19 0.23 0.75 64.29 0 0 6.00 AT EAVE 0.28 0.23 0.42 35.71 0 6.00 TOTAL (MIN)0.46 0.46 1.17 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION NC3G ROOF AREA "D SQ FTG 139 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.19 0.23 0.85 67.03 2 0 AT EAVE 0.28 0.23 0.42 32.97 0 6.00 TOTAL (MIN)0.46 0.46 1.26 100.00 3 HIGH - RIDGE VENT 0.19 0.23 0.75 64.29 0 0 6.00 AT EAVE 0.28 0.23 0.42 35.71 0 6.00 TOTAL (MIN)0.46 0.46 1.17 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2018 Joel Hampshire 03/01/2016 Garage Left TRAILWAY 2179.300.00.CPM LOT 658 08/03/20181900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLOTTED: November 14, 2018 / Annie Lee / 2179-TRAILWAY-IN-WCLY-EL-NC3G.DWG A3-NC3G 3SB.1Northern Crafstman3 Car GarageFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule01/03/19 William Hohlt