HomeMy WebLinkAboutA000.2TOP OF FOUNDATION
TOP OF FLOOR
TOP OF PLATE
WINDOW HEAD HGT.
WINDOW HEAD HGT.
TOP OF PLATE
TOP OF FLOOR
\A1;10'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"128
ROOF SHINGLES, PER SPEC
HORIZONTAL SIDING, PER SPEC
6" FASCIA BOARD, PER SPEC
4" STONE SILL, PER SPECSTONE VENEER, PER SPEC
4" CORNER BOARD, PER SPEC
6" TRIM, PER SPEC
HORIZONTAL SIDING, PER SPEC
4" TRIM, PER SPECHORIZONTAL SIDING, PER SPEC
ROOF SHINGLES, PER SPEC
4:12
3" TRIM OVER 10" FRIEZE BOARD, PER SPEC
1212 1212
10" BAND, PER SPEC
1212
METAL ROOF, PER SPEC
\A1;2'-2{\H0.750000x;\S3#8;}"\A1;TYP.
FYPON BKT10x16x14 OR APPROVED EQUAL
3" FASCIA, PER SPEC
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;PLATE HEIGHT
\A1;2'-8"
\A1;8'-0"
128
\A1;4'-0"
\A1;8'-0"
\A1;9{\H0.750000x;\S1#2;}"\A1;TYP 1x4 TRIM, PER SPEC +12+11+12
SMOOTH PANEL, PER SPEC
8" TRIM, PER SPEC6" TRIM, PER SPEC
SCALE:FRONT ELEVATION1/4" = 1'-0"
124
\A1;17'-3"
\A1;2'-0"
SCALE:REAR ELEVATION1/8" = 1'-0"-
128 128
126
128\A1;2'-8"\A1;8'-0"
SCALE:LEFT ELEVATION1/8" = 1'-0"-
TOP OF FOUND.
TOP OF PLATE
TOP OF PLATE
\A1;10'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
128128 \A1;2'-8"\A1;8'-0"
128
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
\A1;1'-0"\PTYP.\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.
\A1;16'-0"
\A1;4'-0"
PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION
\A1;7'-0"
\A1;6'-0"
\A1;6'-0"
\A1;6'-0"\A1;6'-0"
\A1;1'-0"\PTYP.
MIN. 177 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "E"
SCALE:ROOF PLAN1/8" = 1'-0"-
8:12
8:12 8:12
8:128:12
12:12
ROOF AREASQ. FT."A"2307
ROOF AREASQ. FT."B"311
ROOF AREASQ. FT."C"323
ROOF AREASQ. FT."D"139
12:124:12
6:12
6:12
12:1212:12
4:124:12
8:128:12
6:12
ELEVATION NC3G
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 2308 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 3.08 3.85 3.81 47.78 9 0
AT EAVE 4.62 3.85 4.17 52.22 0 60.00
TOTAL (MIN)7.69 7.69 7.98 100.00
3
HIGH -
RIDGE VENT 3.08 3.85 3.88 48.61 0 0 31.00
AT EAVE 4.62 3.85 4.10 51.39 0 59.00
TOTAL (MIN)7.69 7.69 7.97 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ELEVATION NC3G
ROOF AREA "B"SQ FTG 311 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.41 0.52 0.85 48.41 2 0
AT EAVE 0.62 0.52 0.90 51.59 0 13.00
TOTAL (MIN)1.04 1.04 1.75 100.00
3
HIGH -
RIDGE VENT 0.41 0.52 0.88 49.22 0 0 7.00
AT EAVE 0.62 0.52 0.90 50.78 0 13.00
TOTAL (MIN)1.04 1.04 1.78 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ELEVATION NC3G
ROOF AREA "C"SQ FTG 139 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.19 0.23 0.00 0.00 0 0
AT EAVE 0.28 0.23 0.42 100.00 0 6.00
TOTAL (MIN)0.46 0.46 0.42 100.00
3
HIGH -
RIDGE VENT 0.19 0.23 0.75 64.29 0 0 6.00
AT EAVE 0.28 0.23 0.42 35.71 0 6.00
TOTAL (MIN)0.46 0.46 1.17 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ELEVATION NC3G
ROOF AREA "D SQ FTG 139 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.19 0.23 0.85 67.03 2 0
AT EAVE 0.28 0.23 0.42 32.97 0 6.00
TOTAL (MIN)0.46 0.46 1.26 100.00
3
HIGH -
RIDGE VENT 0.19 0.23 0.75 64.29 0 0 6.00
AT EAVE 0.28 0.23 0.42 35.71 0 6.00
TOTAL (MIN)0.46 0.46 1.17 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2018
Joel Hampshire 03/01/2016
Garage Left
TRAILWAY
2179.300.00.CPM
LOT 658
08/03/20181900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLOTTED: November 14, 2018 / Annie Lee / 2179-TRAILWAY-IN-WCLY-EL-NC3G.DWG
A3-NC3G
3SB.1Northern Crafstman3 Car GarageFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule01/03/19
William Hohlt